Technical Data Sheetp.1VNA Master ™p.1Handheld Vector Network Analyzer + Spectrum Analyzerp.1Introductionp.1High Performance Handheld S-Parametersp.1Performance and Functional Highlightsp.2VNA Master Functional Specificationsp.3Port 1 Port 2p.3S 21p.3S 11p.3DUTp.3S 22p.3S 12p.3Receiverp.3Port 1p.3Port 2p.3Referencep.3Sourcep.3Uncertainty Curves for Round-Trip Cable Loss Measurements (1-Port)p.4High Port Powerp.5Low Port Powerp.6+ Spectrum Analyzer Functional Specifications (Models MS2036/38C only)p.9+ Spectrum Analyzer Functional Specifications (Models MS2036/38C only) (continued)p.10VSWRp.10VNA Performance Capabilities (MS202x/3xC)p.11+ Spectrum Analyzer Performance Capabilitiesp.12Measurement Options Specificationsp.13Time Domain (Option 0002) (includes Distance Domain Option 0501)p.13Power Monitor (Option 0005) Requires external detectorp.13Power Monitor Detectors* (Ordered separately):p.13Secure Data Operation (Option 0007)p.13Bias Tee (Option 0010)p.14Vector Voltmeter (Option 0015)p.14USB Power Sensors (Ordered separately):p.15Interference Analyzer (Option 0025) (Models MS2036/38C only) (Recommend GPS)p.15Channel Scanner (Option 0027) (Models MS2036/38C only)p.15GPS (Option 0031), (Models MS2036/38C only) Requires external GPS antennap.16Balanced/Differential S-Parameters, 1-port (Option 0077)p.16Distance Domain (Option 0501) (included in Time Domain Option 0002)p.16VNA Master General Specifications (MS202x/3xC)p.17Setup Parametersp.17Size and Weightp.17Safetyp.17Environmentalp.17Connectorsp.17Electromagnetic Compatibilityp.17Displayp.17Powerp.17Ancillary Module extends Optical Fiber Testing to Distance-to-Faultp.18Specificationsp.18General Specificationsp.18Input and Output Portsp.18Master Software Tools and Remote Programmingp.19Ordering Informationp.20MS2026C 1p.20MS2028C 1p.20MS2036C 1p.20MS2038C 1p.20VNA Master, 2-port, VNA 5 kHz to 6 GHzp.20VNA Master, 2-port, VNA 5 kHz to 20 GHzp.20VNA Master + Spectrum Analyzer, S/A 9 kHz to 9 GHzp.20VNA Master + Spectrum Analyzer, S/A 9 kHz to 20 GHzp.20Options Descriptionp.20MS2026C-0002 MS2028C-0002 MS2036C-0002 MS2038C-0002 Time Domain (includes DTF capability)p.20MS2026C-0005 MS2028C-0005 – – Power Monitor (requires external detector)p.20MS2026C-0007 MS2028C-0007 MS2036C-0007 MS2038C-0007 Secure Data Operationp.20MS2026C-0010 MS2028C-0010 MS2036C-0010 MS2038C-0010 Built-in Bias-Teep.20– MS2028C-0011 – MS2028C-0011 K(f) Test Port Connectorsp.20MS2026C-0015 MS2028C-0015 MS2046C-0015 MS2038C-0015 Vector Voltmeterp.20– – MS2036C-0025 MS2038C-0025 Interference Analysis, 9 kHz to 9/20 GHz 2p.20– – MS2036C-0027 MS2038C-0027 Channel Scanner, 9 kHz to 9/20 GHz 2p.20MS2026C-0098 MS2028C-0098 MS2036C-0098 MS2038C-0098 Z-540 Calibrationp.20MS2026C-0099 MS2028C-0099 MS2036C-0099 MS2038C-0099 Premium Calibrationp.20Ordering Information (continued)p.21Optional Accessoriesp.21Technical Data Sheet 10580-00548 VNA Master + Spectrum Analyzer Brochurep.21Waveguide Calibration Components and WG/ Coaxial Adaptersp.22CPR187F, CPR187G, UG-1352/U, UG-1353/U, UG-1728/U, UG-1729/U, UG-148/U, UG-149A/Up.22
Page 1 of the Anritsu MS2038C user manual — Introduction
Page 1 · click to enlarge
Page 1

Technical Data Sheet

VNA Master ™

Handheld Vector Network Analyzer + Spectrum Analyzer

MS2026C MS2036C MS2028C MS2038C 5 kHz to 6 GHz 5 kHz to 6 GHz 5 kHz to 20 GHz 5 kHz to 20 GHz Vector Network Analyzer 9 kHz to 9 GHz 9 kHz to 20 GHz + Spectrum Analyzer

The Ultimate Handheld Vector Network + Spectrum Analyzer for Cable, Antenna and Signal Analysis Anytime, Anywhere

Introduction

High Performance Handheld S-Parameters

Anritsu introduces the MS202x/3xC VNA Master + Spectrum Analyzer, the industry’s broadest frequency handheld solution to address cable, antenna, component and signal analysis needs in the field: with frequency coverage from 5 kHz to 6/20 GHz. Equally impressive, this broadband measurement tool offers the industry’s first 12-term error correction algorithm in a truly handheld, battery-operated, rugged multi-function instrument. And now the MS2036/38C models include a powerful spectrum analyzer which multiplies user convenience by combining spectrum analysis with the VNA into a single measurement powerhouse for the harsh RF and physical environments of field test. Whether it is for spectrum monitoring, broadcast proofing, interference analysis, RF and microwave measurements, regulatory compliance, or 3G/4G and wireless data network measurements, this VNA/Spectrum Analyzer marriage is the ideal instrument to making fast and reliable measurements in the field.

Anritsu MS2038C — Introduction diagram (page 1)
Fig. 1 · Introduction
Page 2 of the Anritsu MS2038C user manual —
Page 2 · click to enlarge
Page 2

Performance and Functional Highlights

  • VNA Master
  • Broadband coverage of 5 kHz to 6/20 GHz
  • True 2-port Vector Network Analyzer (VNA)
  • Ultimate accuracy with 12-term error correction
  • User-defined quad display for viewing all 4 S-Parameters
  • Arbitrary data points up to 4001
  • IF Bandwidth selections of 10 Hz to 100 kHz
  • 85 dB dynamic range to 20 GHz
  • Supports waveguide measurements
  • 350 µs/data point sweep speed
  • USB/Ethernet for PC data transfer and control
  • Automate repetitive tasks via Ethernet & USB
  • Field upgradable firmware
  • Store more than 4000 traces and setups in memory
  • Portable: 10.5 lbs (4.8 kg)
  • Full Speed USB Memory support
  • High resolution daylight viewable TFT color display
  • Time Domain option for Distance-to-Fault diagnostics
  • Internal Bias Tee option
  • Vector Voltmeter option
  • High Accuracy Power Meter option
  • Differential option (S d 1 d 1 , S c 1 c 1 , S d 1 c 1 , and S c 1 d 1 )
  • Secure Data Operation option
  • GPS Receiver option
  • Power Monitor option
  • Polar Format Impedance Display
  • 4, 6, 8, 18, 26 GHz USB Power Sensors
  • 8.4 in. Display
  • VNA Master + Spectrum Analyzer All of the above VNA features PLUS:
  • Measure: Occupied Bandwidth, Channel Power, ACPR, C/I
  • Dynamic Range: > 104 dB in 1 Hz RBW
  • DANL: –160 dBm in 1 Hz RBW
  • Phase Noise: –100 dBc/Hz @ 10 kHz offset at 1 GHz
  • Frequency Accuracy: < ± 25 ppb with GPS On
  • 1 Hz to 10 MHz Resolution Bandwidth (RBW)
  • Traces: Normal, Max Hold, Min Hold, Average, # of Averages
  • Detectors: Peak, Negative, Sample, Quasi-peak, and true RMS
  • Markers: 6, each with a Delta Marker, or 1 Reference with 6 Deltas
  • Limit Lines: up to 40 segments with one-button envelope creation
  • Trace Save-on-Event: crossing limit line or sweep complete
  • Option to automatically optimize sweep-RBW-VBW tradeoff for best possible display
  • Interference Analyzer Option: Spectrogram, Signal Strength, RSSI
  • Channel Scanner Option
  • Zero-span IF Output
  • Gated Sweep
  • GPS tagging of stored traces
  • Internal Preamplifier standard
  • High Accuracy Power Meter Option
  • AM/FM/SSB Demodulation (audio only)

Page 3 of the Anritsu MS2038C user manual —
Page 3 · click to enlarge
Page 3

VNA Master Functional Specifications

  • Definitions
  • All specifications and characteristics apply under the following conditions, unless otherwise stated:
  • After 30 minutes of warm-up time, where the instrument is in VNA Mode and left in the ON state.
  • Temperature range is 23 ºC ± 5 ºC.
  • All specifications apply when using internal reference.
  • All specifications subject to change without notice. Please visit <a href="http://www.us.anritsu.com" rel="nofollow noopener" target="_blank">www.us.anritsu.com</a> for most current data sheet.
  • Typical performance is the measured performance of an average unit.
  • Recommended calibration cycle is 12 months.

Frequency VNA Master Frequency Range: MS2026/36C: 5 kHz to 6 GHz MS2028/38C: 5 kHz to 20 GHz Frequency Accuracy: 1.5 ppm Frequency Resolution: 1 Hz to 375 MHz, 10 Hz to 6 GHz, and 100 Hz to 20 GHz

Typical Test Port Power VNA Master supports selection of either High (default) or Low test port power. Changing power after calibration can degrade the calibrated performance. Typical power by bands is shown in the following table.

Block Diagram As shown in the following block diagram, the VNA Master has a 2-port, 2-path architecture that automatically measures four S-parameters with a single connection.

Port 1 Port 2

S 21

Frequency RangeHigh Port Power (dB)Low Port Power (dBm) 5 kHz to ≤ 3 GHz+3–25 3 GHz to ≤ 6 GHz–3–25 6 GHz to ≤ 20 GHz–3–15

S 11

DUT

S 22

S 12

Transmission Dynamic Range The transmission dynamic range (the difference between test port power and noise floor) using 10 Hz IF Bandwidth and High Port Power is shown in the following table.

Receiver

Receiver

Port 1

Port 2

Reference

Receiver

Frequency RangeDynamic Range (dB) 5 kHz to ≤ 2 MHz85 2 MHz to ≤ 3 GHz100 3 GHz to ≤ 6 GHz90 6 GHz to ≤ 20 GHz85

Source

The above illustration is a simplified block diagram of VNA Master’s 2-port, 2-path architecture.

Typical Sweep Speed The typical sweep speed for IF Bandwidth of 100 kHz, 1001 data points, and single display is shown in the following table. The three receiver architecture will simultaneously collect S21 and S11 (or S12 and S22 ) in a single sweep.

Frequency RangeTypical Sweep Speed (µs/point) 5 kHz to 6 GHz350 6 GHz to 20 GHz650

Bridge/ Coupler · Bridge/ Coupler · Switch

Page 4 of the Anritsu MS2038C user manual — Uncertainty Curves for Round-Trip Cable Loss Measurements (1-Port)
Page 4 · click to enlarge
Page 4

Uncertainty Curves for Round-Trip Cable Loss Measurements (1-Port)

Round-trip cable loss measurements are convenient for field personnel testing installed cable or waveguide runs. This one-port technique provides one-way data after twice traversing the cable. The following two sets of uncertainty curves, less than 6 GHz on the left and greater than 6 GHz on the right, present worst-case uncertainty by DUT Match (i.e., Log Mag) when using VNA Master for one-port cable loss measurements. As a practical tip, consider using a two-port transmission measurement technique to improve upon these one-port cable loss uncertainties.

VNA Master (MS20xxC), 5 kHz - 6 GHz One Port Cable Loss (Log Mag / 2) Uncertainty vs. DUT Match

VNA Master (MS20xxC), 6 - 20 GHz One Port Cable Loss (Log Mag / 2) Uncertainty vs. DUT Match

0 1 2 3 4 5 6 7 8 9 10

0 1 2 3 4 5 6 7 8 9 10

Cable Loss, Log Mag / 2 (dB)

Cable Loss, Log Mag / 2 (dB)

These uncertainty curves show how frequency range, DUT Match, and cable loss impact worst-case uncertainty of round-trip cable loss measurements. The uncertainty curves, separated by frequency range, are shown for DUT Match conditions of 20, 25, and 30 dB. For DUT Match of 30 dB and cable loss of 4-5 dB (reflection measurement of 8-10 dB) the worst-case uncertainties are approximately ±1 dB.

Show 8 more labels / short text on this page
Uncertainty (dB) · Uncertainty (dB) · -20 dB · -20 dB · -25 dB · -25 dB · -30 dB · -30 dB
Page 5 of the Anritsu MS2038C user manual —
Page 5 · click to enlarge
Page 5

High Port Power

Anritsu MS2038C — High Port Power diagram (page 5)
Fig. 2 · High Port Power

OSLxx50 Calibration Components (N-Connectors) Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOLT calibration including isolation using either OSLN50 & OSLNF50 or OSLK50 & OSLKF50 Calibration Kits

Precision calibration standards come in a convenient configuration for field work.

Frequency Range (GHz)Typical High Port Power (dBm) ≤ 3+3 ≤ 6–3 ≤ 20–3

Frequency Range (GHz) Directivity (dB)

≤ 5 > 42

≤ 15 > 36

≤ 20* > 32

* N Connector guaranteed to 18 GHz, typical > 18 GHz

Measurement Uncertainties The following graphs provide measurement uncertainty at 23 ºC ± 5 ºC for the above indicated connector type and calibration. Errors are worse-case contributions of residual directivity, source match, frequency response, network analyzer dynamic range, and connector repeatability. For two-port measurements, transmission tracking, crosstalk, and physical load match termination were added. Isolation calibration and an IF Bandwidth of 10 Hz is used.

Anritsu MS2038C — High Port Power diagram (page 5)
Fig. 3 · High Port Power
Anritsu MS2038C — High Port Power diagram (page 5)
Fig. 4 · High Port Power

-80 -70 -60 -50 -40 -30 -20 -10 0 0.01

-40 -35 -30 -25 -20 -15 -10 -5 0

Anritsu MS2038C — High Port Power diagram (page 5)
Fig. 5 · High Port Power
Anritsu MS2038C — High Port Power diagram (page 5)
Fig. 6 · High Port Power

-40 -35 -30 -25 -20 -15 -10 -5 0

-80 -70 -60 -50 -40 -30 -20 -10 0

Show 4 more labels / short text on this page
S11 Magnitude · S21 Magnitude · S21 Phase · S11 Phase
Page 6 of the Anritsu MS2038C user manual —
Page 6 · click to enlarge
Page 6

Low Port Power

OSLxx50 Calibration Components Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOLT calibration including isolation using either OSLN50 & OSLNF50 or OSLK50 & OSLKF50 Calibration Kits

Anritsu MS2038C — Low Port Power diagram (page 6)
Fig. 7 · Low Port Power
Frequency Range (GHz)Typical High Port Power (dBm) ≤ 3–25 ≤ 6–25 ≤ 20–15
Anritsu MS2038C — Low Port Power diagram (page 6)
Fig. 8 · Low Port Power

* N Connector guaranteed to 18 GHz, typical > 18 GHz

Measurement Uncertainties The following graphs provide measurement uncertainty at 23 ºC ± 5 ºC for the above indicated connector type and calibration. Errors are worse-case contributions of residual directivity, source match, frequency response, network analyzer dynamic range, and connector repeatability. For two-port measurements, transmission tracking, crosstalk, and physical load match termination were added. Isolation calibration and an IF Bandwidth of 10 Hz is used.

Anritsu MS2038C — Low Port Power diagram (page 6)
Fig. 9 · Low Port Power
Anritsu MS2038C — Low Port Power diagram (page 6)
Fig. 10 · Low Port Power

-80 -70 -60 -50 -40 -30 -20 -10 0 0.01

-40 -35 -30 -25 -20 -15 -10 -5 0

Anritsu MS2038C — Low Port Power diagram (page 6)
Fig. 11 · Low Port Power
Anritsu MS2038C — Low Port Power diagram (page 6)
Fig. 12 · Low Port Power

-40 -35 -30 -25 -20 -15 -10 -5 0

-80 -70 -60 -50 -40 -30 -20 -10 0

Show 4 more labels / short text on this page
S11 Magnitude · S21 Magnitude · S21 Phase · S11 Phase
Page 7 of the Anritsu MS2038C user manual — High Port Power
Page 7 · click to enlarge
Page 7

High Port Power

Anritsu MS2038C — High Port Power diagram (page 7)
Fig. 13 · High Port Power

3652A Calibration Kit (K-Connector) Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOLT calibration including isolation using 3652A Calibration Kit

Frequency Range (GHz)Directivity (dB) ≤ 5> 42 ≤ 15> 36 ≤ 20*> 32
Frequency Range (GHz)Typical High Port Power (dBm) ≤ 3+3 ≤ 6–3 ≤ 20–3

* N Connector guaranteed to 18 GHz, typical > 18 GHz

Measurement Uncertainties The following graphs provide measurement uncertainty at 23 ºC ± 5 ºC for the above indicated connector type and calibration. Errors are worse-case contributions of residual directivity, source match, frequency response, network analyzer dynamic range, and connector repeatability. For two-port measurements, transmission tracking, crosstalk, and physical load match termination were added. Isolation calibration and an IF Bandwidth of 10 Hz is used.

Anritsu MS2038C — High Port Power diagram (page 7)
Fig. 14 · High Port Power
Anritsu MS2038C — High Port Power diagram (page 7)
Fig. 15 · High Port Power

-40 -35 -30 -25 -20 -15 -10 -5 0

-80 -70 -60 -50 -40 -30 -20 -10 0

Anritsu MS2038C — High Port Power diagram (page 7)
Fig. 16 · High Port Power
Anritsu MS2038C — High Port Power diagram (page 7)
Fig. 17 · High Port Power

-40 -35 -30 -25 -20 -15 -10 -5 0

-80 -70 -60 -50 -40 -30 -20 -10 0

Show 4 more labels / short text on this page
S11 Magnitude · S21 Magnitude · S11 Phase · S21 Phase
Page 8 of the Anritsu MS2038C user manual —
Page 8 · click to enlarge
Page 8

Low Port Power

Anritsu MS2038C — Low Port Power diagram (page 8)
Fig. 18 · Low Port Power

3652A Calibration Kit (K-Connector) Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOLT calibration including isolation using 3652A Calibration Kit

Frequency Range (GHz)Directivity (dB) ≤ 5> 42 ≤ 15> 36 ≤ 20*> 32
Frequency Range (GHz)Typical Low Port Power (dBm) ≤ 3–25 ≤ 6–25 ≤ 20–25

* N Connector guaranteed to 18 GHz, typical > 18 GHz

Measurement Uncertainties The following graphs provide measurement uncertainty at 23 ºC ± 5 ºC for the above indicated connector type and calibration. Errors are worse-case contributions of residual directivity, source match, frequency response, network analyzer dynamic range, and connector repeatability. For two-port measurements, transmission tracking, crosstalk, and physical load match termination were added. Isolation calibration and an IF Bandwidth of 10 Hz is used.

Anritsu MS2038C — Low Port Power diagram (page 8)
Fig. 19 · Low Port Power
Anritsu MS2038C — Low Port Power diagram (page 8)
Fig. 20 · Low Port Power

-80 -70 -60 -50 -40 -30 -20 -10 0 0.01

-40 -35 -30 -25 -20 -15 -10 -5 0

Anritsu MS2038C — Low Port Power diagram (page 8)
Fig. 21 · Low Port Power
Anritsu MS2038C — Low Port Power diagram (page 8)
Fig. 22 · Low Port Power

-40 -35 -30 -25 -20 -15 -10 -5 0

-80 -70 -60 -50 -40 -30 -20 -10 0

Show 4 more labels / short text on this page
S11 Magnitude · S21 Magnitude · S11 Phase · S21 Phase
Page 9 of the Anritsu MS2038C user manual —
Page 9 · click to enlarge
Page 9

+ Spectrum Analyzer Functional Specifications (Models MS2036/38C only)

Frequency Range9 kHz to 20 GHz (usable to 0 Hz), Preamp 100 kHz to 20 GHz Tuning Resolution1 Hz Frequency ReferenceAging: ± 1.0 ppm/10 years Accuracy: ± 0.3 ppm (25 °C ± 25 °C) + aging External Reference Frequencies1, 1.2288, 1.544, 2.048, 2.4576, 4.8, 4.9152, 5, 9.8304, 10, 13, 19.6608 MHz Frequency Span10 Hz to 20 GHz including zero span Sweep Time10 μs to 600 seconds in zero span Sweep Time Accuracy± 2% in zero span
Resolution Bandwidth (RBW)1 Hz to 10 MHz in 1–3 sequence ± 10% (–3 dB bandwidth) Video Bandwidth (VBW)1 Hz to 10 MHz in 1–3 sequence (–3 dB bandwidth) RBW with Quasi-Peak Detection200 Hz, 9 KHz, 120 kHz (–6 dB bandwidth) VBW with Quasi-Peak DetectionAuto VBW is On, RBW/VBW = 1

–100 dBc/Hz @ 10 kHz offset from carrier (–104 dBc/Hz typical) –102 dBc/Hz @ 100 kHz offset from carrier (–107 dBc/Hz typical) –107 dBc/Hz @ 1 MHz offset from carrier (–114 dBc/Hz typical) –120 dBc/Hz @ 10 MHz offset from carrier (–129 dBc/Hz typical)

SSB Phase Noise at 1 GHz

Dynamic Range> 104 dB @ 2.4 GHz, 2/3 (TOI-DANL) in 1 Hz RBW Measurement RangeDANL to +30 dBm Display Range1 to 15 dB/div in 1 dB steps, ten divisions displayed Reference Level Range–120 dBm to +30 dBm Attenuator Resolution0 to 65 dB, 5 dB steps Amplitude UnitsLog Scale Modes: dBm, dBV, dBmv, dBμVLinear Scale Modes: nV, μV, mV, V, kV, nW, μW, mW, W, kW Maximum Continuous Input+30 dBm Peak, ± 50 VDC (≥ 10 dB Attn) +23 dBm Peak, ± 50 VDC (< 10 dB Attn) +13 dBm Peak, ± 50 VDC (Preamp On)

Amplitude Accuracy (single sine wave input < Ref level, and > DANL, auto attenuation)

20 °C to 30 °C after 30 minute warm-upTypical: ± 0.5 dB, 100 kHz to 20 GHz Maximum: ± 1.3 dB, 100 kHz to 13 GHz Add ± 1.0 dB, 13 GHz to 20 GHz –10 °C to 50 °C after 60 minute warm-upAdd ± 1.0 dB, 100 kHz to 20 GHz

Displayed Average Noise Level (DANL) (RMS detection, VBW/Avg type = Log., Ref Level = –20 dBm for preamp Off and –50 dBm for preamp On)

(DANL in 1 Hz RBW, 0 dB attenuation)Preamp Off 10 MHz to 4 GHz–141 dBm > 4 GHz to 9 GHz–134 dBm > 9 GHz to 13 GHz–129 dBm > 13 GHz to 20 GHz–123 dBm (MS2038C only) Preamp On 10 MHz to 4 GHz–160 dBm > 4 GHz to 9 GHz–156 dBm > 9 GHz to 13 GHz–152 dBm > 13 GHz to 20 GHz–145 dBm

Show 4 more labels / short text on this page
Frequency · Bandwidth · Spectral Purity · Amplitude Ranges
Page 10 of the Anritsu MS2038C user manual — VSWR
Page 10 · click to enlarge
Page 10

+ Spectrum Analyzer Functional Specifications (Models MS2036/38C only) (continued)

Preamp Off (RF input terminated, 0 dB input attenuation) –90 dBm 9 kHz to 13 GHz –85 dBm 13 GHz to 20 GHz

Preamp On (RF input terminated, 0 dB input attenuation) –100 dBm 1 MHz to 20 GHz

Input-Related Spurious (0 dB attenuation, –30 dBm input, span < 1.7 GHz) –60 dBc, –70 dBc typical

Third-Order Intercept (TOI) (–20 dBm tones 100 kHz apart, –20 dBm Ref level, 0 dB input attenuation, preamp Off)

2.4 GHz +15 dBm

50 MHz to 20 GHz +20 dBm typical

< 4 GHz +5 dBm typical

4 GHz to 20 GHz +12 dBm typical

50 MHz –54 dBc

< 4 GHz –60 dBc typical

> 4 GHz –75 dBc typical

VSWR

> 10 dB input attenuation < 20 GHz 1:5:1 typical

Show 4 more labels / short text on this page
Spurs · Residual Spurious · P1dB · Second Harmonic Distortion
Page 11 of the Anritsu MS2038C user manual — VNA Performance Capabilities (MS202x/3xC)
Page 11 · click to enlarge
Page 11

VNA Performance Capabilities (MS202x/3xC)

Measurement ParametersS11, S21, S22, S12, S d1d1, S c1c1, S d1c1, S c1d1 Number of TracesFour: TR1, TR2, TR3, TR4 Trace FormatSingle, Dual, Tri, Quad. When used with Number of Traces, overlays are possible including a Single Format with Four trace overlays. Graph TypesLog Magnitude SWR Phase Real Imaginary Group Delay Smith Chart Log Mag / 2 (1-Port Cable Loss) Linear Polar Log Polar Real Impedance Imaginary Impedance DomainsFrequency Domain, Time Domain, Distance Domain FrequencyStart Frequency, Stop Frequency, Center Frequency, Span DistanceStart Distance, Stop Distance TimeStart Time, Stop Time Frequency Sweep Type: LinearSingle Sweep, Continuous Data Points2 to 4001 (arbitrary setting); data points can be reduced without recalibration. Limit LinesUpper, Lower, 10 segmented Upper, 10 segmented Lower Test LimitsPass/Fail for Upper, Pass/Fail for Lower, Limit Audible Alarm Data AveragingSweep-by-sweep Smoothing0 to 20% IF Bandwidth10, 30, 100, 300, 1k, 3k, 10k, 30k, 100k (Hz) Reference PlaneThe reference planes of a calibration (or other normalization) can be changed by entering a line length. Assumes no loss, flat magnitude, linear phase, and constant impedance. Auto Reference Plane ExtensionInstead of manually entering a line length, this feature automatically adjusts phase shift from the current calibration (or other normalization) to compensate for external cables (or test fixtures). Assumes no loss, flat magnitude, linear phase, and constant impedance. Frequency RangeFrequency range of the measurement can be narrowed within the calibration range without recalibration. Group Delay ApertureDefined as the frequency span over which the phase change is computed at a given frequency point. The aperture can be changed without recalibration. The minimum aperture is the frequency range divided by the number of points in calibration and can be increased to 20% of the frequency range. Group Delay Range< 180º of phase change within the aperture Trace MemoryA separate memory for each trace can be used to store measurement data for later display. The trace data can be saved and recalled. Trace MathComplex trace math operations of subtraction, addition, multiplication, or division are provided. Number of MarkersEight, arbitrary assignments to any trace Marker TypesReference, Delta Marker Readout StylesLog Mag, Cable Loss (Log Mag / 2), Log Mag and Phase, Phase, Real and Imaginary, SWR, Impedance, Admittance, Normalized Impedance, Normalized Admittance, Polar Impedance, and Group Delay, Linear Mag, Linear Mag and Phase Marker SearchPeak Search, Valley Search, Find Marker Value Correction ModelsFull 2-Port, Full S11, Full S22, Full S11 & S22, Response S21, Response S12, Response S21 & S12, Response S11, Response S22, Response S11 & S22, One-Path Two-Port (S11,S21), One-Path Two-Port (S22,S12) Calibration MethodsShort-Open-Load-Through (SOLT), Offset-Short (SSLT), and Triple-Offset-Short (SSST) Calibration Standards’ CoefficientsCoax: N-Connector, K-Connector, 7/16, TNC, SMA, and four User Defined Waveguide: WG11A, WG12, WG13, WG14, WG15, WG16, WG17, WG18, WG20, and four User Defined Cal Correction ToggleOn/Off Dispersion CompensationWaveguide correction that improves accuracy of distance-to-fault data by compensating for different wavelengths propagating at different speeds. Impedance ConversionSupport for 50 Ω and 75 Ω are provided. UnitsMeters, Feet Bias Tee SettingsInternal, External, Off Timebase ReferenceInternal, External (10 MHz) File Storage TypesMeasurement, Setup (with CAL), Setup (without CAL), S2P (Real/Imag), S2P (Lin Mag/Phase), S2P (Log Mag/Phase), JPEG Ethernet ConfigurationDHCP or Manual (Static); IP, Gateway, Subnet entries LanguagesEnglish, French, German, Spanish, Chinese, Japanese, Korean, Italian, plus two User Defined
Page 12 of the Anritsu MS2038C user manual — + Spectrum Analyzer Performance Capabilities
Page 12 · click to enlarge
Page 12

+ Spectrum Analyzer Performance Capabilities

Field Strength (uses antenna calibration tables to measure dBm/m2 or dBmV/m) Occupied Bandwidth (measures 99% to 1% power channel of a signal) Channel Power (measures the total power in a specified bandwidth) ACPR (adjacent channel power ratio) C/I (carrier-to-interference ratio) Emission Mask (recall limit lines as emission mask)

FrequencyCenter/Start/Stop, Span, Frequency Step, Signal Standard, Channel # AmplitudeReference Level (RL), Scale, Attenuation Auto/Level, RL Offset, Pre-Amp On/Off, Detection SpanSpan, Span Up/Down (1-2-5), Full Span, Zero Span, Last Span BandwidthRBW, Auto RBW, VBW, Auto VBW, RBW/VBW, Span/RBW FileSave, Recall, Delete, Directory Management Save/RecallSetups, Measurements, Limit Lines, Screen Shots Jpeg (save only), Save-on-Event Save-on-EventCrossing Limit Line, Sweep Complete, Save-then-Stop, Clear All DeleteSelected File, All Measurements, All Mode Files, All Content Directory ManagementSort Method (Name/Type/Date), Ascend/Descend, Internal/USB, Copy Application OptionsImpedance (50 Ω, 75 Ω, Other)
SweepSingle/Continuous, Manual Trigger, Reset, Detection, Minimum Sweep Time, Trigger Type Sweep ModeFast, Performance, No FFT DetectionPeak, RMS/Avg, Negative, Sample, Quasi-peak TriggersFree Run, External, Video, Delay, Level, Slope, Hysteresis, Holdoff, Force Trigger Once
TracesUp to three Traces (A, B, C), View/Blank, Write/Hold, Trace A/B/C Operations Trace A OperationsNormal, Max Hold, Min Hold, Average, # of Averages, (always the live trace) Trace B OperationsA→B, B↔C, Max Hold, Min Hold Trace C OperationsA→C, B↔C, Max Hold, Min Hold, A – B→C, B – A→C, Relative Reference (dB), Scale
MarkersMarkers 1-6 each with a Delta Marker, or Marker 1 Reference with Six Delta Markers, Marker Table (On/Off/Large), All Markers Off Marker TypesStyle (Fixed/Tracking), Noise Marker, Frequency Counter Marker Marker Auto-PositionPeak Search, Next Peak (Right/Left), Peak Threshold %, Set Marker to Channel, Marker Frequency to Center, Delta Marker to Span, Marker to Reference Level Marker Table1-6 markers frequency and amplitude plus delta markers frequency offset and amplitude
Limit LinesUpper/Lower, On/Off, Edit, Move, Envelope, Advanced, Limit Alarm, Default Limit Limit Line EditFrequency, Amplitude, Add Point, Add Vertical, Delete Point, Next Point Left/Right Limit Line MoveTo Current Center Frequency, By dB or Hz, To Marker 1, Offset from Marker 1 Limit Line EnvelopeCreate Envelope, Update Amplitude, Number of Points (41), Offset, Shape Square/Slope Limit Line AdvancedType (Absolute/Relative), Mirror, Save/Recall
Show 7 more labels / short text on this page
Measurements · Smart Measurements · Setup Parameters · Sweep Functions · Trace Functions · Marker Functions · Limit Line Functions
Page 13 of the Anritsu MS2038C user manual — Secure Data Operation (Option 0007)
Page 13 · click to enlarge
Page 13

Measurement Options Specifications

Time Domain (Option 0002) (includes Distance Domain Option 0501)

The VNA Master can also display the S-parameter measurements in the time or distance domain using lowpass or bandpass processing analysis modes. The broadband frequency coverage coupled with 4001 data points means you can measure discontinuities both near and far with unprecedented clarity for a handheld tool. With this option, you can simultaneously view S-parameters in frequency, time, and distance domain to quickly identify faults in the field. Advanced features available with this option include step response, phasor impulse, gating, and frequency gated in time. The option includes computational routines that further enhance the Distance Domain results by compensating for cable loss, relative velocity of propagation, and dispersion compensation in waveguide.

Round-Trip (reflection) Fault Resolution (meters): (0.5 x c x Vp) / ∆F; (c is speed of light = 3E8 m/s, ∆F is F2 – F1 in Hz)

One-Way (transmission) Fault Resolution (meters): (c x Vp) / ∆F; (c is speed of light = 3E8 m/s, ∆F is F2 – F1 in Hz)

Horizontal Range (meters): 0 to (data points – 1) x Fault Resolution to a maximum of 3000 m (9843 ft.)

Windowing Rectangular, Nominal Side Lobe (NSL), Low Side Lobe (LSL), and Minimum Side Lobe (MSL)

Power Monitor (Option 0005) Requires external detector

Transmitter measurements in the field are possible when using this VNA Master software mode with a separately purchased Anritsu 560 series detector. A variety of detectors are available to 50 GHz, but the popular 560-7N50B covers 10 MHz to 20 GHz with a measurement range of –50 to +20 dBm with better than 0.5 dB flatness to 18 GHz. After zeroing the detector to ensure accuracy at low power levels, the software offers intuitive operation for absolute and relative readouts in dBm or Watts.

Power Monitor Detectors* (Ordered separately):

Part Numbers 560-7N50B 560-7S50B

Frequency Range 0.01 to 20 GHz 0.01 to 20 GHz

Impedance 50 Ω 50 Ω

Power Range –55 dBm to +16 dBm –55 dBm to +16 dBm

15 dB, < 0.04 GHz 22 dB, < 8 GHz 17 dB, < 18 GHz 14 dB, < 20 GHz

15 dB, < 0.04 GHz 22 dB, < 8 GHz 17 dB, < 18 GHz 14 dB, < 20 GHz

Display Range –80 to +80 dBm (10 pW to 100 kW)

Measurement Range –50 to +20 dBm (10 nW to 40 mW)

Input Connector N(m) WSMA(m)

Offset Range 0 to +60 dB

Frequency Response ±0.5 dB, < 18 GHz ±1.25 dB, < 20 GHz

±0.5 dB, < 18 GHz ±1.25 dB, < 20 GHz

Resolution 0.1 dB, 0.1 xW (x = n, µ, m based on detector power)

*See www.us.anritsu.com for additional detectors

Accuracy ±1 dB maximum for >–40 dBm using 560-7N50B detector

Secure Data Operation (Option 0007)

For highly secure data handling requirements, this software option prevents the storing of measurement setup or data information onto any internal file storage location. Instead, setup and measurement information is stored ONLY to the external USB memory location. A simple factory preset prepares the VNA Master for transportation while the USB memory remains behind in the secure environment. The VNA Master cannot be switched between secure and non-secure operation by the user once configured for secure data operation. As an additional security measure, with this option enabled the user can choose to blank the frequency values displayed on the screen.

Distance Domain · Return Loss

Page 14 of the Anritsu MS2038C user manual — Bias Tee (Option 0010)
Page 14 · click to enlarge
Page 14

Bias Tee (Option 0010)

Vector Voltmeter (Option 0015)

For tower mounted amplifier tests, the MS20x/3xC series with optional internal bias tees can supply both DC and RF signals on the center conductor of the cable during measurements. For frequency sweeps in excess of 2 MHz, the VNA Master can supply internal voltage control from +12 to +32 V in 0.1 V steps up to 450 mA. To extend battery life, an external power supply can substitute for the internal supply by using the external bias inputs instead. Both test ports can be configured to supply voltage via this integrated bias tees option. Bias can be directed to VNA Port 1 or Port 2.

A phased array system relies on phase matched cables for nominal performance. For this class of application, the VNA Master offers this special software mode to simplify phase matching cables at a single frequency. The similarity between the popular vector voltmeter and this software mode ensures minimal training is required to phase match cables. Operation is as simple as configuring the display for absolute or relative measurements. The easy-to-read large fonts show either reflection or transmission measurements using impedance, magnitude, or VSWR readouts. For instrument landing system (ILS) or VHF Omni-directional Range (VOR) applications, a table view improves operator efficiency when phase matching up to twelve cables. The MS202x/3xC solution is superior because the signal source is included internally, precluding the need for an external signal generator.

Frequency Range 2 MHz to 6 GHz (MS20x6C) 2 MHz to 20 GHz (MS20x8C)

Internal Voltage/Current +12V to +32V at 450 ma. Steady rate

Internal Resolution 0.1V

External Voltage/Current ±50 V at 500 mA steady rate

CW Frequency Range 5 kHz to 20 GHz

Bias Tee Selections Internal, External, Off

Measurement Display CW, Table (Twelve Entries, Plus Reference)

Measurement Types Return Loss, Insertion

Port 1 Port 2

External Bias Input (±50 V, 500 mA Max)

Anritsu MS2038C — Bias Tee (Option 0010) diagram (page 14)
Fig. 23 · Bias Tee (Option 0010)
Anritsu MS2038C — Bias Tee (Option 0010) diagram (page 14)
Fig. 24 · Bias Tee (Option 0010)
Anritsu MS2038C — Bias Tee (Option 0010) diagram (page 14)
Fig. 25 · Bias Tee (Option 0010)

Internal Bias +12 to +32 V 450 mA Max

The VNA Master offers optional integrated bias tee for supplying DC plus RF to the DUT as shown in this simplified block diagram. Connectivity is also provided for external supply (instead of internal) to preserve battery consumption.

Show 7 more labels / short text on this page
Measurement Format dB/VSWR/Impedance · Internal Bias Tee · Switch · Internal Bias Tee · RF Test · Switch · Source
Page 15 of the Anritsu MS2038C user manual — Channel Scanner (Option 0027) (Models MS2036/38C only)
Page 15 · click to enlarge
Page 15

High Accuracy Power Meter (Option 0019) Requires external USB power sensor.

Conduct precise measurements of CW and digitally modulated transmitters in the field using this VNA Master software mode with a separately purchased Anritsu USB power sensor. After specifying the center frequency and zeroing the sensor to ensure accuracy at low power levels, the software offers intuitive operation for absolute and relative readouts in dBm or Watts. Option 0019 supports the USB Power Sensors in the following table.

USB Power Sensors (Ordered separately):

Anritsu MS2038C — USB Power Sensors (Ordered separately): diagram (page 15)
Fig. 26 · USB Power Sensors (Ordered separately):

Frequency Range 50 MHz to 6 GHz 600 MHz to 4 GHz 50 MHz to 6 GHz 10 MHz to 8 GHz 10 MHz to 18 GHz

Connector Type N, male, 50 Ω Type N, female, Ω Type N, male, 50 Ω Type N, male, 50 Ω Type N, male, 50 Ω

Dynamic Range –30 dBm to +20 dBm (0.001 mW to 100 mW)

+3 dBm to +51.76 dBm (2 mW to 150 W)

–40 dBm to +23 dBm (0.1 µW to 200 mW)

–40 dBm to +20 dBm (0.1 µW to 100 mW)

–40 dBm to +20 dBm (0.1 µW to 100 mW)

VBW 100 Hz 100 Hz 100 Hz 50 kHz 50 kHz

Measurement True-RMS. Slot Power, Burst Average Power

Measurement Uncertainty ±0.16 dB1 ±0.17 dB2 ±0.16 dB1 ±0.18 dB3 ±0.18 dB3

Datasheet for Additional Specifications 11410-00414 11410-00483 11410-00424 11410-00504 11410-00504

Notes: 1) Total RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than –20 dBm with zero mismatch errors 2) Expanded uncertainty with K=2 for power measurements of a CW signal greater than +20 dBm with a matched load. Measurement results referenced to the input side of the sensor. 3) Expanded uncertainty with K=2 for power measurements of a CW signal greater than –20 dBm with zero mismatch errors

Interference Analyzer (Option 0025) (Models MS2036/38C only) (Recommend GPS)

Spectrum Field Strength Occupied Bandwidth Channel Power Adjacent Channel Power (ACPR) AM/FM/SSB Demodulation (Wide/Narrow FM, Upper/Lower SSB), (audio out only) Carrier-to-Interference ratio (C/I) Spectrogram (Collect data up to one week) Signal Strength (Gives visual and aural indication of signal strength) Received Signal Strength Indicator (RSSI) (collect data up to one week) Gives visual and aural indication of signal strength Signal ID (up to 12 signals) Center Frequency Bandwidth Signal Type (FM, GSM, W-CDMA, CDMA, Wi-Fi) Closest Channel Number Number of Carriers Signal-to-Nose Ratio (SNR) > 10 dB

Application Options Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)

Channel Scanner (Option 0027) (Models MS2036/38C only)

Anritsu MS2038C — Channel Scanner (Option 0027) (Models MS2036/38C only) diagram (page 15)
Fig. 27 · Channel Scanner (Option 0027) (Models MS2036/38C onl…

Number of Channels 1 to 20 Channels (Power Levels)

Measurements Graph/Table, Max Hold (On/5 sec/Off), Frequency/Channel, Current/Maximum, Dual Color

Scanner Scan Channels, Scan Frequencies, Scan Customer List, Scan Script Master™

Custom Scan Signal Standard, Channel, # of Channels, Channel Step Size, Custom Scan

Frequency Accuracy ± 10 Hz + Time base error

Application Options Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other) )

Measurements

Page 16 of the Anritsu MS2038C user manual — Distance Domain (Option 0501) (included in Time Domain Option 0002)
Page 16 · click to enlarge
Page 16

GPS (Option 0031), (Models MS2036/38C only) Requires external GPS antenna

Built-in GPS provides location information (latitude, longitude, altitude) and Universal Time (UT) information for storage along with trace data so you can later verify that measurements were taken at the right location. The GPS option requires a separately ordered magnet mount GPS antenna (2000-1528-R), which is configured with a 15 foot (~5 m) cable to mount outside on a metallic surface. Frequency accuracy is enhanced for the Spectrum Analyzer when Options 0025 Interference Analyzer and 0027 Channel Scanner are engaged.

Setup On/Off, Antenna Voltage 3.3/5.0 V, GPS Info

GPS Time/Location Indicator Time, Latitude, Longitude and Altitude on display Time, Latitude, Longitude and Altitude with trace storage

High Frequency Accuracy Spectrum Analyzer, Interference Analyzer, CW Signal Generator when GPS Antenna is connected < ± 50 ppb with GPS On, 3 minutes after satellite lock in selected mode

GPS Lock – after antenna is disconnected < ± 50 ppb for 3 days, 0 °C to 50 °C ambient temperature

Balanced/Differential S-Parameters, 1-port (Option 0077)

As an alternative to a sampling oscilloscope, verifying the performance and identifying discontinuities in high-data-rate differential cables is now possible with the VNA Master. After a full two-port calibration, connect your differential cable directly to the two test ports and reveal the Sd1d1 performance, which is essentially differential return loss, or any of the other differential S-Parameters, Sc1c1, Sd1c1, or Sc1d1. With optional time domain, you can convert frequency sweeps to distance. This capability is especially valuable for applications in high data rate cables where balanced data formats are used to isolate noise and interference.

Distance Domain (Option 0501) (included in Time Domain Option 0002)

Distance Domain Analysis is a powerful field test tool to analyze cables for faults, including minor discontinuities that may occur due to a loose connection, corrosion, or other aging effects. By using Frequency Domain Reflectometry (FDR), the VNA Master exploits a user-specified band of full power operational frequencies (instead of DC pulses from TDR approaches) to more precisely identify cable discontinuities. The VNA Master converts S-parameters from frequency domain into distance domain on the horizontal display axis, using a mathematical computation called Inverse Fourier Transform. Connect a reflection at the opposite end of the cable and the discontinuities appear versus distance to reveal any potential maintenance issues. When access to both ends of the cable is convenient, a similar distance domain analysis is available on transmission measurements.

Option 0501 Distance Domain will improve your productivity with displays of the cable in terms of discontinuities versus distance. This readout can then be compared against previous measurements (from stored data) to determine whether any degradations have occurred since installation (or the last maintenance activity). More importantly, you will know precisely where to go to fix the problem and so minimize or prevent downtime of the system.

Connector SMA, female

Page 17 of the Anritsu MS2038C user manual — Power
Page 17 · click to enlarge
Page 17

VNA Master General Specifications (MS202x/3xC)

Setup Parameters

Size and Weight

Anritsu MS2038C — Setup Parameters diagram (page 17)
Fig. 28 · Setup Parameters

Status (Temperature, Battery Info, S/N, Firmware Ver, IP Address, Options Installed) Self Test, Application Self Test GPS (see Option 0031)

Anritsu MS2038C — Setup Parameters diagram (page 17)
Fig. 29 · Setup Parameters

Depth 78 mm (3.1 in) (MS202xC) 97 mm (3.8 in) (MS203xC)

Name, Date and Time, Ethernet Configuration, Brightness, Volume Language (English, French, German, Spanish, Chinese, Japanese, Korean, Italian, User defined) Reset (Factory Defaults, Master Reset, Update Firmware)

Weight, Including Battery 4.5 kg (9.9 lbs) (MS202xC) 4.8 kg (10.5 lbs) (MS203xC)

Safety

Safety Class EN 61010-1 Class 1

Delete Selected File, All Measurements, All Mode Files, All Content

Product Safety IEC 60950-1 when used with Anritsu supplied Power Supply

Environmental

Anritsu MS2038C — Environmental diagram (page 17)
Fig. 30 · Environmental

External Trace/Setup Memory Limited by size of USB Flash drive

Temperature, operating (ºC) (3.8.2.1 & 4.5.5.14) Passed, –10 ºC to 55 ºC, Humidity 85%

Mode Switching Auto-Stores/Recalls most recently used Setup Parameters in the Mode

Temperature, not operating (ºC) (3.8.2.2 & 4.5.5.1) Passed, –51 ºC to 71 ºC

Connectors

Anritsu MS2038C — Connectors diagram (page 17)
Fig. 31 · Connectors

Altitude, not operating (3.8.3 & 4.5.5.2) Passed*, 4600 m

Type N female (or K female with opt 0011, MS20x8C only) VNA port (x2)

Type BNC female Bias Tee port (enabled with opt 0010) (x2)

Spectrum Analyzer Connectors Type N, female (or K female with opt 0011) (MS203xC)

Salt exposure structural parts (3.8.8.2 & 4.5.6.2.2) Not Required***

External Power 5.5 mm barrel connector, 12 to 15 VDC, < 5.0 Amps

LAN Connection RJ48C, 10/100 Mbps, Connect to PC or LAN for Remote Access (Available with opt 0411 Ethernet)

* Qualified by similarity (tested on a similar product) ** Not defined in standard; must be invoked and defined by purchase description *** Not required for Class 2 equipment

USB Interface (2) Type A, Connect Flash Drive and Power Sensor

USB Interface 5-pin mini-B, Connect to PC for data transfer

Electromagnetic Compatibility

Anritsu MS2038C — Electromagnetic Compatibility diagram (page 17)
Fig. 32 · Electromagnetic Compatibility

European Union CE Mark, EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC and Low Voltage Directive 73/23/EEC, 93/68/EEC

External Trigger BNC, female, 50 Ω, Maximum Input ± 5 VDC

Display

Size 8.4 in, daylight viewable color LCD

Resolution 800 x 600

Power

Anritsu MS2038C — Power diagram (page 17)
Fig. 33 · Power
Field replaceable Li-Ion Battery (633-446600 mAh, 4.5 Amps) 40 Watts on battery power only

DC power from Universal 110/220V AC/DC Adapter 55 Watts running off AC/DC adaptor while charging battery

Page 18 of the Anritsu MS2038C user manual — Input and Output Ports
Page 18 · click to enlarge
Page 18

Ancillary Module extends Optical Fiber Testing to Distance-to-Fault

The ODTF-1 module is primarily intended for field use by technicians and engineers responsible for the deployment and maintenance of remote radio heads (RRH), and nicely complements the field diagnostic power of the VNA Master. The ODTF-1 module is fully compatible with the MS202x/3xC VNA Masters which are equipped with the Time Domain Option 0002 or Distance Domain Option 0501. Field operation of the ODTF-1 module with the VNA Master requires the normal DTF (RF/ microwave) mode along with simple modification of some of the setup parameters such as Vp, cable loss, and frequency.

Anritsu MS2038C — Ancillary Module extends Optical Fiber Testing to Distance-to-Fault diagram (page 18)
Fig. 34 · Ancillary Module extends Optical Fiber Testing to Di…

VNA Master users need only to connect a short cable between the RF output of the VNA and the ODTF-1 module and perform a 1-port calibration at the end of the cable. Essentially the ODTF-1 module is simply a wavelength translator, RF test signals in, RF signals returning. The same physics that apply to the traditional DTF measurements apply to ODTF-1 meaning highly accurate measurements can be made with event resolution as good as 10 cm. The same trade-offs carry over as well so better event resolution translates to shorter maximum distance, and vice-versa. Max distance is specified at 1020 meters (3345 ft).

The battery life of the ODTF-1 module matches the battery life of the VNA Master. It can be charged with the same 40-168-R power supply so there is no need to maintain different power supplies.

Using a VNA Master equipped with Option 0002 or 0501, this ODTF-1 optical module translates the optical signals to the RF domain of the VNA, to display fault locations in standard optical fibers.

Specifications

General Specifications

Wavelength 1550 nm typical

External DC Input +12.5 to +15 VDC, 3A maximum

Frequency Range 1 GHz to GHz

Electromagnetic Compatibility Meets European Community requirements for CE marking

Fiber Type Single Mode Fiber (SMF)

Temperature Operating 0 to 50 ºC

Event Resolution 10.2 cm (0.335 ft) maximum, or 150/(n*∆F), ∆F in MHz, n is IOR

Horizontal Range 1020 meter (3345 ft) maximum, or (#dp-1)*Event Resolution

Non-operating 0 to 70 ºC recommended

Optical Dynamic Range 30 dB

Size and Weight

Size 15.7*5.37*18.6 cm (6.18*2.11*7.3 in.)

Optical Output Power 3 dBm typical

Weight < 1 kg (2.2 lbs)

Input and Output Ports

Max RF Input Power + 5 dBm

RF Connector N(m) · Optical Connector FC/APC

Page 19 of the Anritsu MS2038C user manual — Master Software Tools and Remote Programming
Page 19 · click to enlarge
Page 19

Master Software Tools and Remote Programming

Each VNA Master ships with a versatile test assistant: a copy of Anritsu’s Master Software Tools for Windows® 2000/XP/Vista/7. This allows an operator to add the processing capabilities of a PC and this software utility to the VNA Master to form a powerful and flexible measurement solution for network analysis. For automation, the VNA Master also supports remote programming via the Ethernet or USB interface.

Anritsu MS2038C — Master Software Tools and Remote Programming diagram (page 19)
Fig. 35 · Master Software Tools and Remote Programming

Connect VNA Master to a PC for archiving and additional post-processing. A standard tilt-bail provides convenient use on a bench.

Powerful data management tool for storing and sifting through measurement results MST simplifies transfers, printing, and archival of displays and setups

Connect to a PC using USB2.0 (full-speed), Ethernet LAN, or Direct Ethernet Unleash powerful MST capabilities by using variety of popular remote interfaces

Store an unlimited number of setups, traces, and JPEGs (limited only by PC memory) Develop libraries of frequently used setups and typical results

Manipulate traces and further optimize displays Versatility to further analyze results without re-taking measurements

Update with the latest firmware Easily download and upgrade to newest features from www.us.anritsu.com

Remote programming via Ethernet or USB Increase throughput by automating repetitive or operator intensive tasks

Feature Benefit

Page 20 of the Anritsu MS2038C user manual — MS2026C-0098 MS2028C-0098 MS2036C-0098 MS2038C-0098 Z-540 Calibration
Page 20 · click to enlarge
Page 20

Ordering Information

MS2026C 1

MS2028C 1

MS2036C 1

MS2038C 1

VNA Master, 2-port, VNA 5 kHz to 6 GHz

VNA Master, 2-port, VNA 5 kHz to 20 GHz

VNA Master + Spectrum Analyzer, S/A 9 kHz to 9 GHz

VNA Master + Spectrum Analyzer, S/A 9 kHz to 20 GHz

Options Description

MS2026C-0002 MS2028C-0002 MS2036C-0002 MS2038C-0002 Time Domain (includes DTF capability)

MS2026C-0005 MS2028C-0005 – – Power Monitor (requires external detector)

MS2026C-0007 MS2028C-0007 MS2036C-0007 MS2038C-0007 Secure Data Operation

MS2026C-0010 MS2028C-0010 MS2036C-0010 MS2038C-0010 Built-in Bias-Tee

– MS2028C-0011 – MS2028C-0011 K(f) Test Port Connectors

MS2026C-0015 MS2028C-0015 MS2046C-0015 MS2038C-0015 Vector Voltmeter

MS2026C-0019 MS2028C-0019 MS2036C-0019 MS2038C-0019 High Accuracy Power Meter (requires external USB sensor)

– – MS2036C-0025 MS2038C-0025 Interference Analysis, 9 kHz to 9/20 GHz 2

– – MS2036C-0027 MS2038C-0027 Channel Scanner, 9 kHz to 9/20 GHz 2

MS2026C-0031 MS2028C-0031 MS2036C-0031 MS2038C-0031 GPS Receiver (requires GPS antenna, 2000-1528-R) MS2026C-0077 MS2028C-0077 MS2036C-0077 MS2038C-0077 Balanced/Differential S-Parameters, 1-port

MS2026C-0098 MS2028C-0098 MS2036C-0098 MS2038C-0098 Z-540 Calibration

MS2026C-0099 MS2028C-0099 MS2036C-0099 MS2038C-0099 Premium Calibration

MS2026C-0501 MS2028C-0501 MS2036C-0501 MS2038C-0501 Distance Domain (included in Option 0002)

MS202x/3xC Standard Accessories 10580-00220 VNA Master User’s Guide 65729 Soft Carrying Case 2300-498 Master Software Tools CD ROM 633-44 Rechargeable Battery, Li-Ion, 6.6 Ah 40-168-R AC-DC Adapter 806-141-R Automotive Cigarette Lighter 12 V DC adapter 3-2000-1498 USB A-type to Mini USB B-type cable, 3.05 m (10 ft.) 2000-1371-R Ethernet cable, 2.13 m (7 ft.) 3-806-152 Ethernet Crossover Cable, 2.13 m (7 ft.) 2000-1520-R USB Flash Drive

Ancillary Equipment ODTF-1 Optical Time Domain Module 15NNF50-1.5C Armored Test Port Cable, 1.5 meter, N(m) to N(f) OSLN50-1 Precision Open/Short/Load, DC to 6 GHz, 42 dB Return Loss

Page 21 of the Anritsu MS2038C user manual — Technical Data Sheet 10580-00548 VNA Master + Spectrum Analyzer Brochure
Page 21 · click to enlarge
Page 21

Ordering Information (continued)

Optional Accessories

Directional Antennas 2000-1411-R 824 MHz to 896 MHz, N(f), 10 dBd, Yagi 2000-1412-R 885 MHz to 975 MHz, N(f), 10 dBd, Yagi 2000-1413-R 1710 MHz to 1880 MHz, N(f), 10 dBd. Yagi 2000-1414-R 1850 MHz to 1990 MHz, N(f), 9.3 dBd, Yagi 2000-1415-R 2400 MHz to 2500 MHz, N(f), 10 dBd, Yagi 2000-1416-R 1920 MHz to 2170 MHz, N(f), 10 dBd, Yagi 2000-1519-R 500 MHz to 3000 MHz, log periodic 2000-1617 600 MHz to 21000 MHz, N(f), 5-8 dBi to 12 GHz, 0-6 dBi to 21 GHz, log periodic

High Accuracy Power Sensor PSN50 High Accuracy Power Sensor, 50 MHz to 6 GHz MA24104A Inline High Power Sensor, 600 MHz to 4 GHz, True RMS MA24106A High Accuracy Power Sensor, 50 MHz to 6 GHz, True RMS MA24108A High Accuracy Power Sensor, 10 MHz to 8 GHz, True RMS MA24118A High Accuracy Power Sensor, 10 MHz to 18 GHz, True RMS MA24126A High Accuracy Power Sensor, 10 MHz to 26 GHz, True RMS

Portable Antennas 2000-1200 806 MHz to 866 MHz, SMA(m), 50 Ω 2000-1473 870 MHz to 960 MHz, SMA(m), 50 Ω 2000-1035 896 MHz to 941 MHz, SMA (m), 50 Ω (1/4 wave) 2000-1030 1710 MHz to 1880 MHz, SMA(m), 50 Ω (1/2 wave) 2000-1474 1710 MHz to 1880 MHz with knuckle elbow (1/2 wave) 2000-1031 1850 MHz to 1990 MHz, SMA(m), 50 Ω (1/2 wave) 2000-1475 1920 MHz to 1980 MHz and 2110-2170 MHz, SMA(m), 50 Ω 2000-1032 2400 MHz to 2500 MHz, SMA(m), 50 Ω (1/2 wave) 2000-1361 2400 MHz to 2500, 5000 to 6000 MHz, SMA(m), 50 Ω 2000-1616 20 MHz to 21000 MHz, N(f), 50 Ω 61532 Antenna Kit (Consists of: 2000-1030, 2000-1031, 2000-1032-R, 2000-1200, 2000-1035, 2000-1361, and carrying pouch)

Power Monitor Detectors 560-7N50B RF Detector, 0.01 to 20 GHz, Type-N(m) 560-7S50B RF Detector, 0.01 to 20 GHz, W-SMA(m)

Detector Extender Cables 800-109 Detector Extender Cable, 7.6m (25 ft) 800-111 Detector Extender Cable, 30.5m (100 ft.)

K Connector Components OSLK50 Precision integrated Open/Short/Load K(m), DC to 20 GHz, 50 Ω OSLKF50 Precision integrated Open/Short/Load K(f), DC to 20 GHz, 50 Ω 22K50 Precision K(m) Short/Open, 40 GHz 22KF50 Precision K(f) Short/Open, 40 GHz 28K50 Precision Termination, DC to 40 GHz, 50 Ω, K(m) 28KF50 Precision Termination, DC to 40 GHz, 50 Ω, K(f) 3652A K Calibration Kit, DC to 40 GHz

Bandpass Filters 1030-114-R 806 MHz to 869 MHz, N(m) to SMA(f), 50 Ω 1030-109-R 824 MHz to 849 MHz, N(m) to SMA (f), 50 Ω 1030-110-R 880 MHz to 915 MHz, N(m) to SMA (f), 50 Ω 1030-105-R 890 MHz to 915 MHz Band, 0.41 dB loss, N(m) to SMA(f), 50 Ω 1030-111-R 1850 MHz to 1910 MHz, N(m) to SMA (f), 50 Ω 1030-106-R 1710 MHz to 1790 MHz Band, 0.34 dB loss, N(m) to SMA(f), 50 Ω 1030-107-R 1910 MHz to 1990 MHz Band, 0.41 dB loss, N(m) to SMA(f), 50 Ω 1030-112-R 2400 MHz to 2484 MHz, N(m) to SMA (f), 50 Ω 1030-155-R 2500 MHz to 2700 MHz, N(m) to N(f), 50 Ω

N-Type Connectors OSLN50 Precision Integrated Open/Short/Load N(m), DC to 18 GHz, 50 Ω OSLNF50 Precision Integrated Open/Short/Load N(f), DCto 18 GHz, 50 Ω 22N50 Precision N(m) Short/Open, 18 GHz 22NF50 Precision N(f) Short/Open, 18 GHz 28N50-2 Precision Termination, DC to 18 GHz, 50 Ω, N(m) 28NF50-2 Precision Termination, DC to 18 GHz, 50 Ω, N(f) OSLN50-1 Precision N(m) Open/Short/Load, 42 dB, 6 GHz OSLNF50-1 Precision N(f) Open/Short/Load, 42 dB, 6 GHz SM/PL-1 Precision N(m) Load, 42 dB, 6 GHz SM/PLNF-1 Precision N(f) Load, 42 dB, 6 GHz

Attenuators 3-1010-122 20 dB, 5 W, DC to 12.4 GHz, N(m) to N(f) 42N50-20 20 dB, 5 W, DC to 18 GHz, N(m) to N(f) 42N50A-30 30 dB, 5 W, DC to 18 GHz, N(m) to N(f) 3-1010-123 30 dB, 50 W, DC to 8.5 GHz, N(m) to N(f) 1010-127-R 30 dB, 150 W, DC to 3 GHz, N(m) to N(f) 3-1010-124 40 dB, 100 W, DC to 8.5 GHz, N(m) to N(f), Uni-directional 1010-121 40 dB, 100 W, DC to 18 GHz, N(m) to N(f), Uni-directional 1010-128-R 40 dB, 150 W, DC to 3 GHz, N(m) to N(f)

TNC Connector Components 1091-53-R Precision TNC(m) Open, 18 GHz, 50 Ω 1091-54-R Precision TNC(m) Short, 18 GHz, 50 Ω 1015-55-R Precision TNC(m) Load, 18 GHz, 50 Ω 1091-55-R Precision TNC(f) Open, 18 GHz, 50 Ω 1091-56-R Precision TNC(f) Short, 18 GHz, 50 Ω 1015-54-R Precision TNC(f) Load, 18 GHz, 50 Ω

7/16 Connector Components 2000-1618-R Precision Open/Short/Load, 7/16(m), 6.0 GHz 2000-1619-R Precision Open/Short/Load, 7/16(f), 6.0 GHz

Technical Data Sheet 10580-00548 VNA Master + Spectrum Analyzer Brochure

Page 22 of the Anritsu MS2038C user manual — CPR187F, CPR187G, UG-1352/U, UG-1353/U, UG-1728/U, UG-1729/U, UG-148/U, UG-149A/U
Page 22 · click to enlarge
Page 22

Ordering Information (continued)

Manuals 10580-00305 VNA Master User’s Guide 10580-00306 VNA Master Programming Manual 10580-00289 VNA Measurement Guide 10580-00244 Spectrum Analyzer Measurement Guide 10580-00240 Power Meter Measurement Guide 10580-00215 ODTF-1 Optical Distance-to-Fault Module – Quick Start Guide

Waveguide Calibration Components and WG/ Coaxial Adapters

Recommended waveguide calibration procedure requires two offset shorts and a precise load. The waveguide/coax adapter, shown attached to test port #2, adapts the VNA Master test ports to the waveguide under test.

Anritsu MS2038C — Waveguide Calibration Components and WG/ Coaxial Adapters diagram (page 22)
Fig. 36 · Waveguide Calibration Components and WG/ Coaxial Ada…

Related Literature, Application Notes 11410-00206 Time Domain for Vector Network Analyzers 11410-00214 Reflectometer Measurements – Revisited 11410-00270 What is Your Measurement Accuracy? 11410-00373 Distance-to-Fault 11410-00387 Primer on Vector Network Analysis 11410-00414 High Accuracy Power Meter, PSN50 11410-00424 USB Power Sensor MA24106A 11410-00483 Inline High Power Sensor MA24104A 11410-00504 Microwave USB Power Sensor MA241x8A 11410-00531 Practical Tips on Making “Vector Voltmeter (VVM)” Phase Measurements using VNA Master (Opt. 15) 11410-00472 Measuring Interference

Type Compatible Flanges 1/8 Offset Short

23UM70 24UM70 26UM70 35UM70N 5.85 to 8.20 GHz WR137, WG14 CAR70, PAR70, UAR 70, PDR70

23UM84 24UM84 26UM84 35UM84N 7.05 to 10.00 GHz WR112, WG15 CBR84, UBR84, PBR84, PDR84

23UM100 24UM100 26UM100 35UM100N 8.20 to 12.40 GHz WR90, WG16 CBR100, UBR100, PBR100, PDR100

23UM120 24UM120 26UM120 35UM120N 10.00 to 15.00 GHz WR75, WG17 CBR120, UBR120, PBR120, PDR120

CPR187F, CPR187G, UG-1352/U, UG-1353/U, UG-1728/U, UG-1729/U, UG-148/U, UG-149A/U

23UA187 24UA187 26UA187 35UA187N 3.95 to 5.85 GHz WR187, WG12

CPR137F, CPR137G, UG-1356/U UG-1357/U, UG-1732/U, UG-1733/U, UG-343B/U, UG-344/U, UG-440B/U, UG-441/U

23UA137 24UA137 26UA137 35UA137N 5.85 to 8.20 GHz WR137, WG14

CPR112F, CPR112G, UG-1358/U, UG-1359/U, UG-1734/U, UG-1735/U, UG-52B/U, UG-51/U, UG-137B/U, UG-138/U

23UA112 24UA112 26UA112 35UA112N 7.05 to 10.00 GHz WR112, WG15

CPR90F, CPR90G, UG-1360/U, UG-1361/U, UG-1736/U, UG-1737/U, UG-40B/U, UG-39/U, UG-135/U, UG-136B/U

23UA90 24UA90 26UA90 35UA90N 8.20 to 12.40 GHz WR90, WG16

23UA62 24UA62 26UA62 35UA62N 12.40 to 18.00 GHz WR62, WG18 UG-541A/U, UG-419/U, UG-1665/U, UG1666/U

23UA42 24UA42 26UA42 35UA42K 17.00 to 26.50 GHz WR42, WG20 UG-596A/U, UG-595/U, UG-597/U UG-598A/U

[1] For Coaxial/Waveguide Adapter part numbers, N designates Type N and K designates K-Connector

Show 10 more labels / short text on this page
Part Number · Coaxial to Universal · Frequency · Waveguide · 3/8 Offset Short · Precision · Range · Load · Waveguide · Adapter[1]
Page 23 of the Anritsu MS2038C user manual — Waveguide Calibration Components and WG/ Coaxial Adapters
Page 23 · click to enlarge
Page 23
Page 23 of the Anritsu MS2038C user manual — Waveguide Calibration Components and WG/ Coaxial Adapters
Page 24 of the Anritsu MS2038C user manual — Waveguide Calibration Components and WG/ Coaxial Adapters
Page 24 · click to enlarge
Page 24
  • Anritsu Corporation 5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan Phone: +81-46-223-1111 Fax: +81-46-296-1238
  • U.S.A. Anritsu Company 1155 East Collins Boulevard, Suite 100, Richardson, TX, 75081 U.S.A. Toll Free: 1-800-ANRITSU (267-4878) Phone: +1-972-644-1777 Fax: +1-972-671-1877
  • Canada Anritsu Electronics Ltd. 700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, Canada Phone: +1-613-591-2003 Fax: +1-613-591-1006
  • Brazil Anritsu Electrônica Ltda. Praça Amadeu Amaral, 27 - 1 Andar 01327-010 - Bela Vista - São Paulo - SP - Brasil Phone: +55-11-3283-2511 Fax: +55-11-3288-6940
  • Mexico Anritsu Company, S.A. de C.V.
  • Italy Anritsu S.p.A. Via Elio Vittorini, 129, 00144 Roma, Italy Phone: +39-06-509-9711 Fax: +39-06-502-2425
  • Sweden Anritsu AB Borgafjordsgatan 13, 164 40 KISTA, Sweden Phone: +46-8-534-707-00 Fax: +46-8-534-707-30
  • Finland Anritsu AB Teknobulevardi 3-5, FI-01530 VANTAA, Finland Phone: +358-20-741-8100 Fax: +358-20-741-8111
  • Denmark Anritsu A/S (for Service Assurance) Anritsu AB (for Test & Measurement) Kirkebjerg Allé 90 DK-2605 Brøndby, Denmark Phone: +45-7211-2200 Fax: +45-7211-2210
  • Russia Anritsu EMEA Ltd. Representation Office in Russia Tverskaya str. 16/2, bld. 1, 7th floor. Russia, 125009, Moscow Phone: +7-495-363-1694 Fax: +7-495-935-8962
  • United Arab Emirates Anritsu EMEA Ltd. Dubai Liaison Office P O Box 500413 - Dubai Internet City Al Thuraya Building, Tower 1, Suite 701, 7th Floor Dubai, United Arab Emirates Phone: +971-4-3670352 Fax: +971-4-3688460
  • Singapore Anritsu Pte. Ltd. 60 Alexandra Terrace, #02-08, The Comtech (Lobby A) Singapore 118502 Phone: +65-6282-2400 Fax: +65-6282-2533
  • India Anritsu Pte. Ltd. India Branch Office 3rd Floor, Shri Lakshminarayan Niwas, #2726, 80 ft Road, HAL 3rd Stage, Bangalore - 560 075, India Phone: +91-80-4058-1300 Fax: +91-80-4058-1301
  • P. R. China (Hong Kong) Anritsu Company Ltd. Units 4 & 5, 28th Floor, Greenfield Tower, Concordia Plaza, No. 1 Science Museum Road, Tsim Sha Tsui East, Kowloon, Hong Kong, P.R. China Phone: +852-2301-4980 Fax: +852-2301-3545
  • P. R. China (Beijing) Anritsu Company Ltd. Beijing Representative Office Room 2008, Beijing Fortune Building, No. 5 , Dong-San-Huan Bei Road, Chao-Yang District, Beijing 100004, P.R. China Phone: +86-10-6590-9230 Fax: +86-10-6590-9235
  • Korea Anritsu Corporation, Ltd. 8F Hyunjuk Bldg. 832-41, Yeoksam-Dong, Kangnam-ku, Seoul, 135-080, Korea Phone: +82-2-553-6603 Fax: +82-2-553-6604
  • Australia Anritsu Pty Ltd. Unit 21/270 Ferntree Gully Road, Notting Hill Victoria, 3168, Australia Phone: +61-3-9558-8177 Fax: +61-3-9558-8255
  • Taiwan Anritsu Company Inc. 7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, Taiwan Phone: +886-2-8751-1816 Fax: +886-2-8751-1817
  • Av. Ejército Nacional No. 579 Piso 9, Col. Granada 11520 México, D.F., México Phone: +52-55-1101-2370 Fax: +52-55-5254-3147
  • U.K. Anritsu EMEA Ltd. 200 Capability Green, Luton, Bedfordshire LU1 3LU, U.K. Phone: +44-1582-433280 Fax: +44-1582-731303
  • France Anritsu S.A.

12 Avenue du Québec, Bâtiment Iris 1-Silic 638, 91140 VILLEBON SUR YVETTE, France Phone: +33-1-60-92-15-50 Fax: +33-1-64-46-10-65 • Germany Anritsu GmbH Nemetschek Haus, Konrad-Zuse-Platz 1 81829 München, Germany Phone: +49 (0) 89 442308-0 Fax: +49 (0) 89 442308-55

11410-00548, Rev. B Printed in United States 2010-09 ©2010 Anritsu Company. All Rights Reserved ®Anritsu All trademarks are registered trademarks of

their respective companies. Data subject to change without notice. For the most recent specifications visit: www.anritsu.com

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Anritsu MS2038C

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Anritsu MS2038C

Be the first to ask — other owners or our team will answer.

Original document

Anritsu MS2038C manual PDF

24 pages·2.8 MB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…