Technical Data Sheet Introduction High Performance Handheld S-Parameters Anritsu introduces the MS202x/3xC VNA Master + Spectrum Analyzer , the industry’ s broadest frequency handheld solution to add ress cable , anten na, co mpone nt and si gnal an alys is need s in the fi eld: wi th freq uenc y cove rage fr om 5 kHz to 6/ 20 GHz.
2 Performance and Functional Highlights VNA Master • Broadband coverage of 5 kHz to 6/20 GHz • T rue 2-port V ector Network Analyzer (VNA) • Ultimate accuracy with 12-term error correction • U.
3 VNA Master Functional Specifications Definitions • All specifications and characteristics apply under the following conditions, unless otherwise stated: • After 30 minutes of warm-up time, where the instrument is in VNA Mode and left in the ON state.
4 These uncertainty curves show how frequency range, DUT Match, and cable loss impact worst-case uncertainty of round-trip cable loss measur ements. The uncertainty curves, separated by frequency range, are shown for DUT Match conditions of 20, 25, and 30 dB.
5 High Port Power OSLxx50 Calibration Components (N-Connectors) Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOL T calibration including isolation using either OSLN50 & OSLNF50 or OSLK50 & OSLKF50 Calibration Kits Pr ecision calibration standards come in a convenient configuration for field work.
6 Low Port Power OSLxx50 Calibration Components Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOL T calibration including isolation using either OSLN50 & OSLNF50 or.
7 High Port Power 3652A Calibration Kit (K-Connector) Corrected System Performance and Uncertainties : MS202x/3xC Model with 12-term SOL T calibration including isolation using 3652A Calibration Kit F.
8 Low Port Power 3652A Calibration Kit (K-Connector) Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOL T calibration including isolation using 3652A Calibration Kit Fre.
9 + Spectrum Analyzer Functional Specifications (Models MS2036/38C only) Freq ue ncy Freq uenc y R ang e 9 k Hz t o 20 GH z (us abl e to 0 H z), Pre amp 100 kHz to 20 G Hz T un ing Res olut io n 1 Hz Freq uenc y Re fer enc e Agi ng: ± 1.0 p pm /10 yea rs Ac cur acy : ± 0 .
10 + Spectrum Analyzer Functional Specifications (Models MS2036/38C only) (continued) Spu rs Res idua l S pur iou s Pre amp Of f (RF inp ut t er mina ted, 0 d B in put at tenu ati on) – 90 dB m 9 kH.
11 VNA Performance Capabilities (MS202x/3xC) Me asu re me nt P ara me te rs S 1 1 , S 2 1 , S 2 2 , S 1 2 , S d 1 d 1 , S c 1 c 1 , S d 1 c 1 , S c 1 d 1 Nu mb er o f Trac es Fou r: T R1, TR 2, TR3 , T R4 T r ac e For ma t Sin gle, Du al, T ri , Q uad.
12 + Spectrum Analyzer Performance Capabilities Me asu re me nt s Sma r t M eas urem ent s Fie ld Str eng th (us es ante nna cal ibr ati on tab les to mea sure dB m/m 2 o r d BmV/m) Oc cup ie d Ba ndw.
13 Measurement Options Specifications Time Domain (Option 0002) (includes Distance Domain Option 0501) The VNA Master can also display the S-parameter measurements in the time or distance domain using lowpass or bandpass processing analysis modes.
14 Bias T ee (Option 0010) For tower mounted amplifier tests, the MS20x/3xC series with optional internal bias tees can supply both DC and RF signals on the center conductor of the cable during measurements. For frequency sweeps in excess of 2 MHz, the VNA Master can supply internal voltage control from +12 to +32 V in 0.
15 High Accuracy Power Meter (Option 0019) Requires external USB power sensor . Co nd uc t p re ci se mea su re me nt s o f CW and di gi ta ll y m odu la te d t ra ns mi tt er s in th e f ie ld usi ng th is V NA M ast er so ft wa re mo de wit h a se pa ra te ly pu rc ha se d Anr it su US B po we r s en so r .
16 GPS (Option 0031), (Models MS2036/38C only) Requires external GPS antenna Built-in GPS provides location information (latitude, longitude, altitude) and Universal Time (UT) information for storage along with trace data so you can later verify that measurements were taken at the right location.
17 VNA Master General Specifications (MS202x/3xC) MI L- PRF -28 80 0F , C la ss 2 Env iro nm ent al Co ndi ti on s MS 202 x / 3xC T em per atur e, o per ati ng ( ºC) (3.8 .2 . 1 & 4.5 .5.1 4) P ass ed, –1 0 ºC to 55 ºC , Hu mid it y 8 5% T em per atur e, n ot o per ati ng ( º C) (3.
18 Ancillary Module extends Optical Fiber T esting to Distance-to-Fault The ODTF-1 module is primarily intended for field use by technicians and engineers responsible for the deployment and mai nten ance of re mote ra dio hea ds (RRH ), and ni cely co mple ment s the fie ld diag nost ic powe r of the V NA Maste r .
19 Fea tur e Be ne fi t Powe r ful dat a m ana gem ent too l fo r s tor ing and si ft ing th rou gh m eas ure ment re sult s M ST sim pli fi es t ra nsfe rs, pr int ing , an d ar ch ival of d isp lays and set ups Co nne ct to a PC usin g U SB2 .
20 MS202x/3xC Standard Accessories 10580-00220 VNA Master User ’s Guide 65729 Soft Carrying Case 2300-498 Master Software T ools CD ROM 633-44 Rechargeable Battery , Li-Ion, 6.6 Ah 40-168-R AC-DC Adapter 806-141-R Automotive Cigarette Lighter 12 V DC adapter 3-2000-1498 USB A-type to Mini USB B-type cable, 3.
21 Optional Accessories High Accuracy Power Sensor PSN50 High Accuracy Power Sensor , 50 MHz to 6 GHz MA24104A Inline High Power Sensor , 600 MHz to 4 GHz, T rue RMS MA24106A High Accuracy Power Senso.
22 Ordering Information (continued) Par t Nu mb er Freq ue ncy Ra nge Wave gui de T y pe Co mp at ib le Flan ge s 1/8 O f f set Sh or t 3/ 8 O f fs et Sh or t Pre ci sio n Loa d Coa x ial to Uni ver sa l Wave gui de Ada pt er [1] 23 UM70 24UM 70 26 UM70 35UM 70N 5.
23.
11410-00548, Rev. B Printed in United States 2010-09 ©2010 Anritsu Company. All Rights Reserved ® Anritsu All trademarks are registered trademarks of their respective companies. Data subject to change without notice. For the most recent specifications visit: www.
An important point after buying a device Anritsu MS2026C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Anritsu MS2026C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Anritsu MS2026C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Anritsu MS2026C you will learn all the available features of the product, as well as information on its operation. The information that you get Anritsu MS2026C will certainly help you make a decision on the purchase.
If you already are a holder of Anritsu MS2026C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Anritsu MS2026C.
However, one of the most important roles played by the user manual is to help in solving problems with Anritsu MS2026C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Anritsu MS2026C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center