EN
Kenmore logo
Official user manual

Kenmore 8789

56 pages·1.7 MB·Clothes Dryer·PDF·ENDEFRITNLJA
Kenmore 8789
Table of Contents 61 sections TABLE OF CONTENTS · PROTECTION AGREEMENTS · PROTECTION AGREEMENTS.......................................................2 · INSTALLATION INSTRUCTIONS ..................................................5 · … ShowHide
TABLE OF CONTENTSp.2PROTECTION AGREEMENTSp.2PROTECTION AGREEMENTS.......................................................2p.2INSTALLATION INSTRUCTIONS ..................................................5p.2KENMORE ELITE ® APPLIANCE WARRANTYp.3DRYER SAFETYp.4DANGERp.4You can be killed or seriously injured if you don't followp.4SAVE THESE INSTRUCTIONSp.4INSTALLATION INSTRUCTIONSp.5Pedestal Heightp.5Location Requirementsp.6You will needp.6Installation spacing for cabinet installationp.7Electrical Requirementsp.8It is your responsibilityp.8GROUNDING INSTRUCTIONSp.8Electrical Connectionp.9Power Supply Cord Direct Wirep.9C Dp.94-wire connection: Power supply cordp.104-wire connection: Direct wirep.113-wire connection: Direct wirep.123-wire connection: Power supply cordp.12Optional 3-wire connectionp.13Venting Requirementsp.14If using an existing vent systemp.14If this is a new vent systemp.14Vent materialp.14Plan Vent Systemp.15Choose your exhaust installation typep.15Determine vent pathp.16Install Leveling Legsp.16Determine vent length and elbows needed for best drying performancep.16DRYER USEp.19Starting Your Dryerp.19Cycle tipsp.20Auto Cyclesp.21Auto Dry Preset Cycle Settingsp.21Timed Cyclesp.22Timed Preset Cycle Settingsp.22End of Cycle Signalp.24DRYER CAREp.25Cleaning the Dryer Interiorp.25Cleaning the Lint Screenp.25Removing Accumulated Lintp.25Vacation and Moving Carep.25Vacation carep.25Moving carep.26TROUBLESHOOTINGp.26Dryer Operationp.26Dryer will not runp.26Unusual soundsp.26Dryer displaying code messagep.26No heatp.26Dryer Resultsp.27Cycle time too shortp.27Lint on loadp.27Stains on load or drump.27Loads are wrinkledp.27Odorsp.27
Page 1 of the Kenmore 8789 user manual — ®
Page 1 · click to enlarge
Page 1

®

Electric Dryer Use & Care Guide Secadora eléctrica Manual de uso y cuidado

Models/Modelos 110.8787✼, 8789✼ ✼ = color number/número de color

W10114657 Sears Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com

Page 2 of the Kenmore 8789 user manual — Table of Contents
Page 2 · Contents
Contents

Contents

TABLE OF CONTENTSp.2PROTECTION AGREEMENTSp.2PROTECTION AGREEMENTS.......................................................2p.2INSTALLATION INSTRUCTIONS ..................................................5p.2KENMORE ELITE ® APPLIANCE WARRANTYp.3DRYER SAFETYp.4DANGERp.4You can be killed or seriously injured if you don't followp.4SAVE THESE INSTRUCTIONSp.4INSTALLATION INSTRUCTIONSp.5Pedestal Heightp.5Location Requirementsp.6You will needp.6Installation spacing for cabinet installationp.7Electrical Requirementsp.8It is your responsibilityp.8GROUNDING INSTRUCTIONSp.8Electrical Connectionp.9Power Supply Cord Direct Wirep.9C Dp.94-wire connection: Power supply cordp.104-wire connection: Direct wirep.113-wire connection: Direct wirep.123-wire connection: Power supply cordp.12Optional 3-wire connectionp.13Venting Requirementsp.14If using an existing vent systemp.14If this is a new vent systemp.14Vent materialp.14Plan Vent Systemp.15Choose your exhaust installation typep.15Determine vent pathp.16Install Leveling Legsp.16Determine vent length and elbows needed for best drying performancep.16DRYER USEp.19Starting Your Dryerp.19Cycle tipsp.20Auto Cyclesp.21Auto Dry Preset Cycle Settingsp.21Timed Cyclesp.22Timed Preset Cycle Settingsp.22End of Cycle Signalp.24DRYER CAREp.25Cleaning the Dryer Interiorp.25Cleaning the Lint Screenp.25Removing Accumulated Lintp.25Vacation and Moving Carep.25Vacation carep.25Moving carep.26TROUBLESHOOTINGp.26Dryer Operationp.26Dryer will not runp.26Unusual soundsp.26Dryer displaying code messagep.26No heatp.26Dryer Resultsp.27Cycle time too shortp.27Lint on loadp.27Stains on load or drump.27Loads are wrinkledp.27Odorsp.27
Page 3 of the Kenmore 8789 user manual — KENMORE ELITE ® APPLIANCE WARRANTY
Page 3 · click to enlarge
Page 3

KENMORE ELITE ® APPLIANCE WARRANTY

ONE YEAR LIMITED WARRANTY When installed, operated and maintained according to all instructions supplied with the product, if this appliance fails due to a defect in material or workmanship within one year from the date of purchase, call 1-800-4-MY-HOME® to arrange for free repair. TWO YEAR LIMITED WARRANTY ON SENSOR SMART™ ELECTRONIC BOARD For two years from the date of purchase, when this dryer is installed, operated and maintained according to all instructions supplied with the product, Sears will replace the electronic control board if defective in materials or workmanship. After the first year, customer assumes any labor costs associated with replacement of these parts. If this appliance is used for other than private family purposes, this warranty applies for only 90 days from the date of purchase. THIS WARRANTY COVERS ONLY DEFECTS IN MATERIAL AND WORKMANSHIP. SEARS WILL NOT PAY FOR: 1. Expendable items that can wear out from normal use, including but not limited to filters, belts, light bulbs, and bags. 2. A service technician to instruct the user in correct product installation, operation or maintenance. 3. A service technician to clean or maintain this product. 4. Damage to or failure of this product if it is not installed, operated or maintained according to all instructions supplied with the product. 5. Damage to or failure of this product resulting from accident, abuse, misuse or use for other than its intended purpose. 6. Damage to or failure of this product caused by the use of detergents, cleaners, chemicals or utensils other than those recommended in all instructions supplied with the product. 7. Damage to or failure of parts or systems resulting from unauthorized modifications made to this product.

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES Customer’s sole and exclusive remedy under this limited warranty shall be product repair as provided herein. Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. Sears shall not be liable for incidental or consequential damages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, or limitations on the duration of implied warranties of merchantability or fitness, so these exclusions or limitations may not apply to you. This warranty applies only while this appliance is used in the United States and Canada. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Sears, Roebuck and Co. Dept. 817WA, Hoffman Estates, IL 60179

Sears Canada Inc. Toronto, Ontario, Canada M5B 2B8

PRODUCT RECORD In the space below, record your complete model number, serial number, and purchase date. You can find this information on the model and serial number label located on the product. Have this information available to help you obtain assistance or service more quickly whenever you contact Sears concerning your appliance.

Model number

Save these instructions and your sales receipt for future reference.

Serial number · Purchase date

Page 4 of the Kenmore 8789 user manual — SAVE THESE INSTRUCTIONS
Page 4 · click to enlarge
Page 4

DRYER SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:

DANGER

You can be killed or seriously injured if you don't immediately

follow instructions.

You can be killed or seriously injured if you don't follow

instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

  • Read all instructions before using the dryer.
  • Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.
  • Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
  • Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, drycleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
  • Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
  • Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.
  • Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.
  • Clean lint screen before or after each load.
  • Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.
  • Before the dryer is removed from service or discarded, remove the door to the drying compartment.
  • Do not reach into the dryer if the drum is moving.
  • The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.
  • Do not install or store the dryer where it will be exposed to the weather.
  • See installation instructions for grounding requirements.
  • Do not tamper with controls.

SAVE THESE INSTRUCTIONS

Page 5 of the Kenmore 8789 user manual — Pedestal Height
Page 5 · click to enlarge
Page 5

INSTALLATION INSTRUCTIONS

Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Optional Pedestal Are you placing the dryer on a pedestal? You have the option of purchasing pedestals of different heights separately for this dryer. You may select a 10" (25.4 cm) pedestal or a 15.5" (39.4 cm) pedestal with a storage drawer. The pedestal will add to the total height of the dryer for a total height of approximately 46" (116.8 cm) or 51.5" (130.8 cm), respectively. For a garage installation, you will need to place the 10" (25.4 cm) pedestal at least 9" (22.9 cm) above the floor. You will need to place the 15.5" (39.4 cm) pedestal at least 3" (7.6 cm) above the floor.

  • Flat-blade screwdriver
  • Vent clamps
  • #2 Phillips screwdriver
  • Caulking gun and compound (for installing new exhaust vent)
  • Adjustable wrench that opens to 1" (2.54 cm) or hex-head socket wrench (for adjusting dryer feet)
  • Tin snips (new vent installations)
  • Wire stripper (for direct wire installations)
  • ¼" nut driver or socket wrench (recommended)
  • Level
  • Tape measure

Parts supplied Remove parts package from dryer drum. Check that all parts are included.

Optional pedestal (15.5" [39.4 cm] model shown)

To order, call your local Sears store. For further information, please call 1-800-4-MY-HOME® (1-800-469-4663).

Pedestal Height

10" (25.4 cm) White 46822

15.5" (39.4 cm) White 57822

Parts needed Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.

  • For close-clearance installations between 31.5" (80.01 cm) and 37" (93.98 cm), see “Plan Vent System” section for venting requirements.

Mobile home installations require metal exhaust system hardware available for purchase from your local Sears store or Sears Service Center. For further information, please call 1-800-4-MY-HOME® (1-800-469-4663).

4 Leveling legs · Color Part Number

Page 6 of the Kenmore 8789 user manual — You will need
Page 6 · click to enlarge
Page 6

Location Requirements

Installation clearances The location must be large enough to allow the dryer door to open fully. Dryer Dimensions

50½" (128.27 cm)

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

*31½" (80.01 cm) 27" (68.6 cm)

You will need

  • A location that allows for proper exhaust installation. See “Venting Requirements.”

*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

  • A separate 30-amp circuit.
  • If you are using a power supply cord, a grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See “Electrical Requirements.”

Installation spacing for recessed area or closet installation The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

  • A sturdy floor to support the total dryer weight of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered.
  • Additional spacing should be considered for ease of installation and servicing.
  • A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. (If slope is greater than 1" [2.5 cm], install Extended Dryer Feet Kit, Part Number 279810.) Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.
  • Additional clearances might be required for wall, door and floor moldings.
  • Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
  • For a garage installation, you will need to place the dryer at least 18" (46 cm) above the floor. If you are using a pedestal, you will need 18" (46 cm) to the bottom of the dryer.
  • For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

  • Companion appliance spacing should also be considered.

Custom undercounter installation - Dryer only

38" min. (96.52 cm)

1"* (2.5 cm) 27" (68.6 cm)

Explosion Hazard · *Required spacing

Page 7 of the Kenmore 8789 user manual — Installation spacing for cabinet installation
Page 7 · click to enlarge
Page 7

Closet installation - Dryer only

Recommended installation spacing for recessed or closet installation, with stacked washer and dryer

Kenmore 8789 — Installation spacing for cabinet installation diagram (page 7)
Fig. 1 · Installation spacing for cabinet installation

The dimensions shown are for the recommended spacing.

Kenmore 8789 — Installation spacing for cabinet installation diagram (page 7)
Fig. 2 · Installation spacing for cabinet installation

A. Side view - closet or confined area B. Closet door with vents

1"* (2.5 cm) 24 in.2 * (155 cm2)

*Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed. Recessed or closet installation - Dryer on pedestal

Kenmore 8789 — Installation spacing for cabinet installation diagram (page 7)
Fig. 3 · Installation spacing for cabinet installation
Kenmore 8789 — Installation spacing for cabinet installation diagram (page 7)
Fig. 4 · Installation spacing for cabinet installation

A. Recessed area B. Side view - closet or confined area

Mobile home - additional installation requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).

*Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed.

Installation spacing for cabinet installation

  • For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.

Mobile home installations require:

  • Metal exhaust system hardware, which is available for purchase from your local Sears store or Sears Service Center.
Kenmore 8789 — Installation spacing for cabinet installation diagram (page 7)
Fig. 5 · Installation spacing for cabinet installation
  • Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

*Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed.

*Required spacing · *Required spacing

Page 8 of the Kenmore 8789 user manual — SAVE THESE INSTRUCTIONS
Page 8 · click to enlarge
Page 8

Electrical Requirements

It is your responsibility

If your outlet looks like this:

  • To contact a qualified electrical installer.
  • To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.

The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

  • To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

If your outlet looks like this:

  • Do not use an extension cord.
  • If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

Electrical Connection To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

If connecting by direct wirePower supply cable must match power supply (4-wire or 3-wire) and be:
  • If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section.
  • Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.
  • This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.
  • 10-gauge solid copper wire (do not use aluminum).
  • At least 5 ft (1.52 m) long.

GROUNDING INSTRUCTIONS

  • For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
  • A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.
  • For a permanently connected dryer: This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer. WARNING: Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

If using a power supply cord: Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

  • A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
  • A UL listed strain relief.

SAVE THESE INSTRUCTIONS

4-wire receptacle (14-30R) · 3-wire receptacle (10-30R)

Page 9 of the Kenmore 8789 user manual — D
Page 9 · click to enlarge
Page 9

Electrical Connection

Power Supply Cord Direct Wire

Use a new UL listed 30 amp power supply cord.

Use 10 gauge solid copper wire.

Use a UL listed strain relief.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

Failure to do so can result in death, fire, or electrical shock.

1. Disconnect power. 2. Remove the hold-down screw and terminal block cover.
3. Install strain relief. Style 1: Power supply cord strain relief
  • Remove the screws from a ³⁄₄ " (1.9 cm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws just enough to hold the two clamp sections together.

D

C D

A. Neutral ground wire

B. External ground conductor screw C. Center, silver-colored terminal block screw D. Terminal block cover and hold-down screw

A. Strain relief tab pointing up B. Hole below terminal block opening C. Clamp section D. Strain relief tab pointing down

Fire Hazard · Fire Hazard

Page 10 of the Kenmore 8789 user manual — 4-wire connection: Power supply cord
Page 10 · click to enlarge
Page 10
  • Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
If your home hasAnd you will be connecting to:

4-wire receptacle (NEMA Type 14-30R)

A UL listed, 120/ 240-volt minimum, 30-amp, dryer power supply cord*

4-wire connectionPower supply cord

4-wire direct A fused disconnect or circuit breaker box*

4-wire connectionDirect Wire
Style 2Direct wire strain relief

3-wire receptacle (NEMA type 10-30R)

A UL listed, 120/ 240-volt minimum, 30-amp, dryer power supply cord*

3-wire connectionPower supply cord
  • Unscrew the removable conduit connector and any screws from a ³⁄₄ " (1.9 cm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening. Reaching inside the terminal block opening, screw the removable conduit connector onto the strain relief threads.

3-wire direct A fused disconnect or circuit breaker box*

3-wire connectionDirect Wire
Kenmore 8789 — 4-wire connection: Power supply cord diagram (page 10)
Fig. 6 · 4-wire connection: Power supply cord

*If local codes do not permit the connection of a cabinet-ground conductor to the neutral wire, go to “Optional 3-wire connection” section.

4-wire connection: Power supply cord

Kenmore 8789 — 4-wire connection: Power supply cord diagram (page 10)
Fig. 7 · 4-wire connection: Power supply cord

A. Removable conduit connector B. Hole below terminal block opening C. Strain relief threads

  • Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.

A. 4-wire receptacle (NEMA type 14-30R) B. 4-prong plug C. Ground prong D. Neutral prong

Kenmore 8789 — 4-wire connection: Power supply cord diagram (page 10)
Fig. 8 · 4-wire connection: Power supply cord

E. Spade terminals with upturned ends F. ¾" (1.9 cm) UL listed strain relief G. Ring terminals

4. Now complete installation following instructions for your type of electrical connection: 4-wire (recommended)

3-wire (if 4-wire is not available)

Show 4 more labels / short text on this page
Electrical Connection Options · Go to Section · 5" · 3¹⁄₂"
Page 11 of the Kenmore 8789 user manual — 4-wire connection: Direct wire
Page 11 · click to enlarge
Page 11
1. Remove center silver-colored terminal block screw. 2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver-colored terminal block screw. Tighten screw.

4-wire connection: Direct wire

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections. Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed. Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5" (12.7 cm). Cut 1¹⁄₂" (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends of wires into a hook shape.

Kenmore 8789 — 4-wire connection: Direct wire diagram (page 11)
Fig. 9 · 4-wire connection: Direct wire

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.

A. External ground conductor screw - Dotted line shows

position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw. B. Center silver-colored terminal block screw C. Neutral ground wire D. Neutral wire (white or center wire)

E. ¾" (1.9 cm) UL listed strain relief

3. Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.
Kenmore 8789 — 4-wire connection: Direct wire diagram (page 11)
Fig. 10 · 4-wire connection: Direct wire
1. Remove center silver-colored terminal block screw. 2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.
Kenmore 8789 — 4-wire connection: Direct wire diagram (page 11)
Fig. 11 · 4-wire connection: Direct wire

A. External ground conductor screw B. Ground wire (green or bare) of power supply cord C. ³⁄₄" (1.9 cm) UL listed strain relief D. Center silver-colored terminal block screw

E. Neutral ground wire F. Neutral wire (white or center wire)

4. Connect the other wires to outer terminal block screws. Tighten screws.

A. External ground conductor screw - Dotted line shows

position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw. B. Center silver-colored terminal block screw C. Neutral ground wire D. Neutral wire (white or center wire)

E. ¾" (1.9 cm) UL listed strain relief

5. Tighten strain relief screws. 6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. 7. You have completed your electrical connection. Now go to “Venting Requirements.”

1"

Page 12 of the Kenmore 8789 user manual — 3-wire connection: Direct wire
Page 12 · click to enlarge
Page 12
3. Connect ground wire (green or bare) of direct wire cable to external ground conductor screw. Tighten screw.
1. Loosen or remove center silver-colored terminal block screw. 2. Connect neutral wire (white or center wire) of power supply cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.
Kenmore 8789 — 3-wire connection: Direct wire diagram (page 12)
Fig. 12 · 3-wire connection: Direct wire
Kenmore 8789 — 3-wire connection: Direct wire diagram (page 12)
Fig. 13 · 3-wire connection: Direct wire

A. External ground conductor screw B. Ground wire (green or bare) of power supply cable C. ¾" (1.9 cm) UL listed strain relief D. Center silver-colored terminal block screw

A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)

E. Neutral ground wire F. Neutral wire (white or center wire)

E. ³⁄₄" (1.9 cm) UL listed strain relief

4. Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
3. Connect the other wires to outer terminal block screws. Tighten screws.
4. Tighten strain relief screws. 5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. 6. You have completed your electrical connection. Now go to “Venting Requirements.”
5. Tighten strain relief screw. 6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. 7. You have completed your electrical connection. Now go to “Venting Requirements.”

3-wire connection: Direct wire

3-wire connection: Power supply cord

Use where local codes permit connecting cabinet-ground conductor to neutral wire. Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed. Strip 3¹⁄₂" (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape.

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

Kenmore 8789 — 3-wire connection: Direct wire diagram (page 12)
Fig. 14 · 3-wire connection: Direct wire

A. 3-wire receptacle (NEMA type 10-30R) B. 3-wire plug C. Neutral prong D. Spade terminals with up turned ends

E. ³⁄₄" (1.9 cm) UL listed strain relief F. Ring terminals G. Neutral (white or center wire)

1" · 3¹⁄₂"

Page 13 of the Kenmore 8789 user manual — Optional 3-wire connection
Page 13 · click to enlarge
Page 13

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.

Optional 3-wire connection

Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire. 1. Remove center silver-colored terminal block screw. 2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable under center, silver-colored terminal block screw. Tighten screw.

1. Loosen or remove center silver-colored terminal block screw. 2. Place the hooked end of the neutral wire (white or center wire) of direct wire cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.
Kenmore 8789 — Optional 3-wire connection diagram (page 13)
Fig. 15 · Optional 3-wire connection
Kenmore 8789 — Optional 3-wire connection diagram (page 13)
Fig. 16 · Optional 3-wire connection

A. External ground conductor screw B. Center silver-colored terminal block screw C. Neutral ground wire D. Neutral wire (white or center wire)

A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)

E. ³⁄₄" (1.9 cm) UL listed strain relief F. Grounding path determined by a qualified electrician

3. Connect the other wires to outer terminal block screws. Tighten screws.

E. ³⁄₄" (1.9 cm) UL listed strain relief

3. Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
4. Tighten strain relief screws. 5. Connect a separate copper ground wire from the external ground conductor screw to an adequate ground. 6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
4. Tighten strain relief screw. 5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. 6. You have completed your electrical connection. Now go to “Venting Requirements.”
Page 14 of the Kenmore 8789 user manual — If this is a new vent system
Page 14 · click to enlarge
Page 14

Venting Requirements

  • For best drying performance, rigid metal vents are recommended.
  • Rigid metal vent is recommended to avoid crushing and kinking.
  • Flexible metal vents are acceptable only if accessible for cleaning.
  • Flexible metal vent must be fully extended and supported when the dryer is in its final location.

Use a heavy metal vent.

Do not use a plastic vent.

  • Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

  • Do not install flexible metal vent in enclosed walls, ceilings or floors.

45° elbows provide better airflow than 90° elbows.

If using an existing vent system

  • Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.
  • Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.
  • Use clamps to seal all joints.
  • Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance.
  • Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct. Do not use duct tape.

If this is a new vent system

Vent material

  • Use a heavy metal vent. Do not use plastic or metal foil vent.
  • 4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended.

Recommended hood styles are shown here.

4" (10.2 cm) heavy metal exhaust vent

DURASAFE™ vent products can be purchased from your dealer. For further information, please call 1-800-4-MY-HOME® (1-800-469-4663) or visit our website at www.sears.com.

A. Louvered hood style B. Box hood style

Show 8 more labels / short text on this page
Rigid metal vent · Flexible metal vent · Fire Hazard · Elbows · Good Better · Clamps · Clamp · Exhaust
Page 15 of the Kenmore 8789 user manual — Choose your exhaust installation type
Page 15 · click to enlarge
Page 15

The angled hood style (shown here) is acceptable.

Optional exhaust installations This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted.

Kenmore 8789 — Plan Vent System diagram (page 15)
Fig. 17 · Plan Vent System

2½" (6.4 cm)

  • An exhaust hood should cap the vent to keep rodents and insects from entering the home.
  • Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).
  • Do not use an exhaust hood with a magnetic latch.

Cover unused exhaust holes with one of the following kits:

Kenmore 8789 — Plan Vent System diagram (page 15)
Fig. 18 · Plan Vent System

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Plan Vent System

Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.

Choose your exhaust installation type

Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

Kenmore 8789 — Choose your exhaust installation type diagram (page 15)
Fig. 19 · Choose your exhaust installation type

A. Standard rear offset exhaust installation B. Left or right side exhaust installation C. Bottom exhaust installation (not an option

Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.

A. Dryer B. Elbow C. Wall D. Exhaust hood

E. Clamps F. Rigid metal or flexible metal vent G. Vent length necessary to connect elbows H. Exhaust outlet

Kenmore 8789 — Choose your exhaust installation type diagram (page 15)
Fig. 20 · Choose your exhaust installation type

A. Over-the-top installation (also available with one offset elbow) B. Periscope installation

with pedestal installations)

Page 16 of the Kenmore 8789 user manual — Determine vent length and elbows needed for best drying performance
Page 16 · click to enlarge
Page 16
  • Over-the-Top Installation:

Vent system chart NOTE: Side and bottom exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.

  • Periscope Installation (For use with dryer vent to wall vent mismatch):

Number of 90º turns or elbows

Box or Louvered hoods

Part Number 26-49901 - Less than 5" (12.7 cm) mismatch

Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm) mismatch

0 Rigid metal Flexible metal

64 ft (20 m) 36 ft (11 m) 58 ft (17.7 m) 28 ft (8.5 m)

Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm) mismatch

1 Rigid metal Flexible metal

54 ft (16.5 m) 31 ft (9.4 m) 48 ft (14.6 m) 23 ft (7 m)

Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm) mismatch

2 Rigid metal Flexible metal

44 ft (13.4 m) 27 ft (8.2 m) 38 ft (11.6 m) 19 ft (5.8 m)

Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

3 Rigid metal Flexible metal

35 ft (10.7 m) 25 ft (7.6 m) 29 ft (8.8 m) 17 ft (5.2 m)

4 Rigid metal Flexible metal

27 ft (8.2 m) 23 ft (7 m) 21 ft (6.4 m) 15 ft (4.6 m)

Install Vent System 1. Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood. 2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp. 3. Run vent to dryer location. Use the straightest path possible. See “Determine vent path” in “Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.

Determine vent path

  • Select the route that will provide the straightest and most direct path outdoors.

Install Leveling Legs

  • Plan the installation to use the fewest number of elbows and turns.
  • When using elbows or making turns, allow as much room as possible.
  • Bend vent gradually to avoid kinking.

Use two or more people to move and install dryer.

  • Use the fewest 90° turns possible.

Failure to do so can result in back or other injury.

Determine vent length and elbows needed for best drying performance

1. To protect the floor, use a large flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer. 2. Firmly grasp the body of the dryer (not the console panel). Gently lay the dryer on the cardboard. See illustration.
  • Use the following Vent system chart to determine type of vent material and hood combinations acceptable to use.
  • NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will:
  • Shorten the life of the dryer.
  • Reduce performance, resulting in longer drying times and increased energy usage.

The Vent system chart provides venting requirements that will help to achieve the best drying performance.

3. Examine the leveling legs. Find the diamond marking.
Show 4 more labels / short text on this page
Part Number 26-49900 · Type of vent · Angled hoods · Excessive Weight Hazard
Page 17 of the Kenmore 8789 user manual — Determine vent path
Page 17 · click to enlarge
Page 17
4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible. 5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.
4. Lay the dryer door on a flat, protected surface with the inside door assembly facing up. Remove the 5 screws to release the outer door assembly from the inner door assembly, as indicated below. See illustration. It is important that you remove only the 5 indicated screws.

Connect Vent 1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (10.2 cm) clamp. 2. Move dryer into its final location. Do not crush or kink vent. 3. (On gas models) Check that there are no kinks in the flexible gas line. 4. Once the exhaust vent connection is made, remove the corner posts and cardboard.

5. Lift the inner door assembly off of the outer door assembly. Set the outer door assembly aside.

Reverse the hinge 1. Place the inner door, screw head side up, on the work space. 2. Remove the 4 hinge screws that hold the hinge to the door and remove hinge.

Level Dryer Check the levelness of the dryer. Check levelness first side to side, then front to back.

Kenmore 8789 — Determine vent path diagram (page 17)
Fig. 21 · Determine vent path
Kenmore 8789 — Determine vent path diagram (page 17)
Fig. 22 · Determine vent path

If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for levelness.

Reverse Door Swing You can change your door swing from a right-side opening to a left-side opening, if desired. NOTE: For ease of installation, you may want to use 2 or more people to remove and reattach the dryer door.

A. Hinge side screw B. Locator pins on hinge C. Top side screw

3. Move the large hole screw to the opposite side. Remove the 2 plug screws and plastic plugs, and insert them in the original screw holes on the opposite side.

Remove the door 1. Place a towel or soft cloth on top of the dryer or work space to protect the surface. 2. Open the dryer door. Remove the 5 screws that hold the door hinge on the front panel of the dryer.

Kenmore 8789 — Determine vent path diagram (page 17)
Fig. 23 · Determine vent path

A. Hinge screws B. Large hole screw C. Plug screws and plastic plugs

A. Dryer front panel B. Dryer door C. Screws

3. Remove the door.
Page 18 of the Kenmore 8789 user manual — Determine vent path
Page 18 · click to enlarge
Page 18
4. Move hinge to the other side and reattach with the 4 screws removed in Step 3. Make sure locator pins line up in holes and drive the top 2 screws in place first to help drive locator pins into proper location. 5. Set the inner door assembly aside.
4. Align the door by placing the locating tabs on the hinge with the locating holes on the dryer front panel. Insert and tighten the center hinge screw. The door will hang in place while you insert and tighten the remaining 4 screws. NOTE: Two or more people may be needed to reattach the dryer door.
Kenmore 8789 — Determine vent path diagram (page 18)
Fig. 24 · Determine vent path

Reverse the door handle 1. Place the outer door assembly face down on work space. 2. Remove the 6 screws that hold the intermediate door to the outer door assembly. Remove the intermediate door, and set hinge shield aside. Remove the hinge hole cover.

Kenmore 8789 — Determine vent path diagram (page 18)
Fig. 25 · Determine vent path

A. Dryer door B. Dryer front panel C. Insert this hinge screw first.

5. Close the door and check that it latches securely. 6. Check for fingerprints on the glass. Clean the glass if necessary.

Complete Installation 1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped. 2. Check that you have all of your tools. 3. Dispose of/recycle all packaging materials. 4. Check the dryer’s final location. Be sure the vent is not crushed or kinked. 5. Check that the dryer is level. See “Level Dryer.” 6. For power supply cord installation, plug into an outlet. For direct wire installation, reconnect power. 7. Remove the blue protective film on the console and any tape remaining on the dryer. 8. Read “Dryer Use.” 9. Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust. 10. Select a Timed Dry heated cycle, and start the dryer. Do not select the Air Only Temperature setting. If the dryer will not start, check the following:

A. Intermediate door B. Hinge shield C. Hinge hole cover

3. Rotate the window assembly 180º and reattach the intermediate door, hinge shield and hinge hole cover with the 6 screws removed in Step 2.

Reinstalling the door 1. Place the inner door assembly into the outer door assembly. To fit correctly, the inside door assembly edge is completely inside the outside door assembly edge. 2. Reassemble the inner and outer door assemblies with the 5 screws.

  • Controls are set in a running or “On” position.
  • Start button has been pushed firmly.
  • Dryer is plugged into an outlet and/or electrical supply is connected.
3. Remove existing label from the opposite side of the door and discard. Find label provided with the Use and Care Guide and apply over original hinge holes.
  • Household fuse is intact and tight, or circuit breaker has not tripped.
  • Dryer door is closed.
11. When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close the door. If you do not feel heat, turn off the dryer and check the following:
  • There may be 2 household fuses or circuit breakers for the dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped. If there is still no heat, contact a qualified technician.
Page 19 of the Kenmore 8789 user manual — Starting Your Dryer
Page 19 · click to enlarge
Page 19

DRYER USE

Kenmore 8789 — DRYER USE diagram (page 19)
Fig. 26

Starting Your Dryer

Kenmore 8789 — Starting Your Dryer diagram (page 19)
Fig. 27 · Starting Your Dryer

Keep flammable materials and vapors, such as gasoline, away from dryer.

Do not dry anything that has ever had any type of oil on it (including cooking oils).

Do not dry anything that has ever had anything flammable on it (even after washing).

Items containing foam, rubber, or plastic must be dried on a clothesline or by using an Air Cycle.

Failure to follow these instructions can result in death, explosion, or fire.

Failure to follow these instructions can result in death or fire.

  • Select an Auto Cycle.

WARNING: To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before operating this appliance. Follow these basic steps to start your dryer. Please refer to specific sections of this manual for more detailed information. 1. Clean lint screen before each load. See “Cleaning the Lint Screen.” 2. Place laundry in dryer and shut door. 3. Press the POWER button. Then rotate the dial or press a Timed Cycles button to select the desired Auto or Timed Cycle. The preset settings for Auto Cycles or Timed Cycles will illuminate. The estimated or actual cycle time (in minutes) will show in the display. To use an Auto Cycle

  • Select DRYNESS LEVEL to adjust how dry you want the load. As the cycle runs, the control senses the dryness of the load and adjusts the time automatically for the selected dryness level.
  • Select the desired Options.

To make changes during an Auto Cycle:

  • Press STOP once.
  • Adjust Dryness Level.
Page 20 of the Kenmore 8789 user manual — Cycle tips
Page 20 · click to enlarge
Page 20

How Auto Dry works SmartHeat™ improves drying performance with Auto Moisture Sensing Plus, which advances the cycle as moisture is extracted from clothing. A thermistor (electronic temperature sensor) and moisture sensing strips in the dryer drum help measure the amount of moisture in the clothes as they tumble. An electronic control determines the load type to help save time, avoid overdrying, and increase the accuracy of the end dryness level. After the first 5 minutes of an automatic cycle, the estimated time display will adjust based on the approximate load size, cycle, dryness level selected and amount of moisture left in the clothes. When the clothes have reached approximately 80% of the dryness level selected, the estimated time display will adjust again, showing the final drying time. Auto Moisture Sensing Plus takes the guesswork out of drying time and enhances fabric care.

Pausing or Restarting To pause the dryer at any time Open the door or press STOP once. To restart the dryer Close the door. Press and hold START until dryer starts. NOTE: Drying will continue from where the cycle was interrupted if you close the door and press START within 5 minutes. If the cycle is interrupted for more than 5 minutes, the dryer will shut off. Select new cycle settings before restarting the dryer.

Control Locked This feature allows you to lock your settings to avoid unintended use of the dryer. You can also use the Control Locked feature to avoid unintended cycle or option changes during dryer operation. To enable the Control Locked feature: Press and hold CYCLE SIGNAL for 3 seconds. The Control Locked indicator light glows, and a single beep tone is heard. To unlock, press and hold CYCLE SIGNAL for 3 seconds. The indicator light turns off.

To use a Timed Cycle

  • Press a Timed Cycles button or, to select Air Fluff, rotate the control knob to the desired cycle.
  • Press MORE TIME or LESS TIME until the desired drying time is displayed. Tap MORE TIME or LESS TIME, and the time will change by 1-minute intervals. Press and hold MORE TIME or LESS TIME, and the time will change by 5-minute intervals.

Drying and Cycle Tips Select the correct cycle and dryness level or temperature for your load. If an Auto Cycle is running, the display shows the estimated cycle time, which is determined by your dryer automatically sensing the dryness level of your load. If a Timed Cycle is running, the display shows the exact number of minutes remaining in the cycle. Cool Down tumbles the load without heat during the last few minutes of all cycles. Cool Down makes the loads easier to handle and reduces wrinkling. The length of the Cool Down depends on the load size and dryness level. Drying tips

  • Press TEMPERATURE until the desired temperature glows.
  • Follow care label directions when they are available.
  • If desired, add a fabric softener sheet. Follow package instructions.
  • To reduce wrinkling, remove the load from the dryer as soon as tumbling stops. This is especially important for permanent press, knits and synthetic fabrics.
4. (OPTIONAL STEP) If desired, select OPTIONS. For more details, see “Options.” 5. (OPTIONAL STEP) If desired, set the End of Cycle Signal . Select LOUD or SOFT by pressing the Cycle Signal button to alert you when a cycle ends. 6. Press and hold START for approximately 3 seconds until dryer starts. Be sure the door is closed.
  • Avoid drying heavy work clothes together with lighter fabrics. This could cause overdrying of lighter fabrics and lead to increased shrinkage or wrinkling.

Cycle tips

  • Dry most loads using the preset cycle settings.
  • If you do not press Start within 5 minutes of selecting the cycle, the dryer automatically shuts off.
  • Refer to the Auto Cycles or Timed Cycles Preset Settings chart (in the “Cycles” section) for a guide to drying various loads.
  • If you wish to end your drying cycle after pressing Start, press Stop twice.
  • Drying temperature and Dryness Level are preset when you choose an Auto Cycle. You can select a different dryness level, depending on your load, by pressing Dryness Level and choosing More Dry, Normal or Less Dry.

Stopping Your Dryer To stop your dryer at any time Press STOP twice or open the door.

  • If you wish to adjust the cycle length of a Timed Cycle, press More Time or Less Time. Adjust the temperature of a Timed Cycle by pressing TEMPERATURE until the desired temperature is selected.
Page 21 of the Kenmore 8789 user manual — Auto Dry Preset Cycle Settings
Page 21 · click to enlarge
Page 21

Status Lights You may follow the progress of your dryer with the drying Status indicator lights.

Cycles Select the drying cycle that matches the type of load you are drying. See Auto Dry chart or Timed Preset Cycle Settings chart.

Kenmore 8789 — Auto Cycles diagram (page 21)
Fig. 28 · Auto Cycles

Timed Cycle The Timed Cycle light glows green during a Timed Cycle.

Wet The Wet light glows green at the beginning of Auto Dry if a wet item is detected or in a timed cycle after 5 minutes.

Auto Cycles

  • In an Auto Cycle, if a wet item is not detected after 5 minutes, the dryer will run for a preset minimum run time (based on the selected cycle and dryness level setting) and then go into Cool Down. The Cool Down and WRINKLE GUARD ® indicators will glow green, if selected.

Auto Cycles allow you to match the cycle to the load you are drying. See the following Auto Dry Preset Cycle Settings chart. Each cycle dries certain fabrics at the recommended temperature. A sensor detects the moisture in the load and automatically adjusts the drying time for optimal drying.

  • In a Timed Cycle, the Wet light will glow green after 5 minutes and remain on until the dryer enters Cool Down.

Heavy Duty Use this cycle to get high heat for heavyweight mixed loads, cotton towels or bedspreads.

Damp The Damp light glows green in an Auto Cycle when the laundry is approximately 80% dry. This is useful when you want to remove lightweight items in a mixed load to avoid overdrying or remove partially dry items that may need ironing. To be alerted when the load is about 80% dry, you may use the damp dry signal option. See Damp Dry Signal in “Options.”

Jeans Use this cycle to get medium high heat for drying denims.

Normal Use this cycle to get medium heat for drying sturdy fabrics such as work clothes and sheets.

Cool Down The Cool Down light glows green during the cool down part of the cycle. Laundry cools for ease in handling.

Casual Use this cycle to get low heat for drying no-iron fabrics, such as sport shirts, casual business clothes and permanent press blends.

Clothes Dry The Clothes Dry light glows green when the drying cycle is finished. This indicator stays on during WRINKLE GUARD®.

Delicate Use this cycle to get extra-low heat to gently dry items such as lingerie, blouses or washable knit fabrics.

WRINKLE GUARD® The WRINKLE GUARD® light glows green when this option is selected. This indicator stays on with Clothes Dry.

Auto Dry Preset Cycle Settings

Auto Cycles Load Type

Sensing/Revising Est. Time The Sensing/Revising Est. Time light glows green when moisture sensing strips in the dryer drum are measuring the amount of moisture in the clothes. The estimated time display may adjust to show a more accurate drying time.

HEAVY DUTY Heavyweight mixed loads, cotton towels, bedspreads

Indicator lights Other indicator lights show Cycle, Options, Modifiers, End of Cycle and Control Lock settings selected. The display shows the estimated or actual time remaining.

JEANS Denim jeans, jackets

NORMAL Corduroys, work clothes, sheets

CASUAL Permanent press, synthetics

DELICATE Lingerie, blouses, washable knit fabrics

*Estimated Time with Auto Dry Level (Normal) setting. Time will vary depending on load type and load size.

Show 6 more labels / short text on this page
Temperature Time* (Minutes) · High 45 · Medium High 55 · Medium 40 · Low 35 · Extra Low 30
Page 22 of the Kenmore 8789 user manual — Timed Cycles
Page 22 · click to enlarge
Page 22

Timed Cycles

Timed Preset Cycle Settings

Timed Cycles Load Type

Use Timed Cycles to select a specific amount of drying time and a drying temperature. (Temperatures are not selectable with Air Fluff). When a Timed Cycle is selected, the Estimated Time Remaining display shows the actual time remaining in your cycle. You can change the actual time in the cycle by pressing More Time or Less Time. See “Changing Cycles, Options and Modifiers.”

TIMED DRY Heavyweight, bulky items, bedspreads, work clothes

EXPRESS DRY™ Small loads

Timed Dry Use this cycle to complete drying if items are still damp after an Auto Cycle. Timed Dry is also useful for drying heavyweight and bulky items, such as bedspreads and work clothes. Lightweight garments, such as exercise wear, can be dried using Timed Dry on a low temperature setting. Timed Dry can also be used with the Tumble Free Heated Dryer Rack.

TOUCH UP Helps to smooth out wrinkles

AIR FLUFF Dry without heat

Air Dry (no heat)

*Use the Air Fluff cycle for items that require drying without heat such as rubber, plastic and heat-sensitive fabrics.

EXPRESS DRY™ Use this cycle for drying small loads or loads that need a short drying time.

Options You can customize your cycles by selecting options.

Touch Up Use this cycle to help smooth out wrinkles from items, such as clothes packed in a suitcase or items wrinkled from being left in the dryer too long.

Air Fluff Rotate the dial to Air Fluff to use this cycle for items that require drying without heat such as rubber, plastic and heat-sensitive fabrics. This table shows examples of items that can be dried using Air Fluff. The temperature setting is not adjustable with this cycle.

Type of Load Time* (Minutes)

Foam rubber - pillows, padded bras, stuffed toys 20 - 30

WRINKLE GUARD® WRINKLE GUARD® helps smooth out wrinkles that form when you cannot unload the dryer promptly at the end of a cycle. During this option, the dryer stops tumbling and then tumbles again for a brief period.

Plastic - Shower curtains, tablecloths 20 - 30

Rubber-backed rugs 40 - 50

Olefin, polypropylene, sheer nylon 10 - 20

  • Press WRINKLE GUARD ® to get up to 2 hours of heat-free, periodic tumbling at the end of a cycle.

*Reset cycle to complete drying, if needed. When using Air Fluff

  • Stop WRINKLE GUARD ® at any time by pressing WRINKLE GUARD ® or opening the dryer door.
  • Check that coverings are securely stitched.
  • Shake and fluff pillows by hand periodically during the cycle.
  • For the Casual cycle, WRINKLE GUARD ® is preset to ON. The other cycles will retain the WRINKLE GUARD ® setting. For example, if you select WRINKLE GUARD ® in the Normal cycle, WRINKLE GUARD ® will be on the next time you select the Normal cycle.
  • Dry item completely. Foam rubber pillows are slow to dry.
Show 5 more labels / short text on this page
Default Temperature · Default Time (Minutes) · High 40 · High 23 · Medium High 20
Page 23 of the Kenmore 8789 user manual — Timed Cycles
Page 23 · click to enlarge
Page 23

Damp Dry Signal Select the Damp Dry Signal to alert you that your clothes are approximately 80% dry. This is useful when you want to remove lightweight items in a mixed load to avoid overdrying or remove partially dry items that may need ironing. NOTE: The Damp Dry Signal is available only with the Auto Cycles.

Dryness Level Press DRYNESS LEVEL until the desired Dryness Level is selected. Dryness Level cannot be adjusted with Timed Cycles.

Kenmore 8789 — Timed Cycles diagram (page 23)
Fig. 29 · Timed Cycles

Button Sounds You can change the volume of the sound of the beeps. Press BUTTON SOUNDS until the desired volume (Loud, Soft or Off) glows. The Power and Cancel buttons will still beep softly when the Button Sounds volume is set to Off.

Changing Cycles, Options and Modifiers You can change Auto Cycles, Timed Cycles, Modifiers and Options anytime before pressing Start.

Drum Light Press Drum Light to turn on the light inside the dryer drum. During a cycle, if Drum Light is selected, the drum light turns on and will remain on until DRUM LIGHT is pressed again, the door is open and closed, or the door is left open for 5 minutes. When the dryer is not running, the drum light will turn on when DRUM LIGHT is pressed or the dryer door is opened, and it will remain on until the dryer door has been open for 5 minutes, the dryer door is closed or DRUM LIGHT is pressed again. Press DRUM LIGHT at any time to turn the drum light ON or OFF.

  • Three short tones sound if an unavailable combination is selected. The last selection will not be accepted.

Changing Cycles after pressing Start 1. Press STOP twice. This ends the current cycle. 2. Select the desired cycle and options. 3. Press and hold START. The dryer starts at the beginning of the new cycle. NOTE: If you do not press START within 5 minutes of selecting the cycle, the dryer automatically shuts off.

Modifiers Use Modifiers to select time, temperatures and dryness levels for the Timed Cycles.

Changing Modifiers and Options after pressing Start You can change a Modifier or Option anytime before the selected Modifier or Option begins. 1. Press STOP once. 2. Select the new Modifier and/or Option. 3. Press and hold START to continue the cycle. NOTE: If you happen to press Stop twice, the program clears and your dryer shuts down. Restart the selection process.

Time Press MORE TIME or LESS TIME until the desired drying time is displayed. The time cannot be changed with Auto Cycles.

Changing the Preset Dryness Level Settings If all of your loads on all Auto Dry cycles are consistently not as dry as you would like, you may change the preset Dryness Level settings to increase the dryness. This change will affect all of your Auto Dry cycles. Your Dryness Level settings can be adjusted to adapt to different installations, environmental conditions or personal preference. There are 3 drying settings: 1 (factory preset dryness level), 2 (slightly dryer clothes, approximately 15% more drying time) and 3 (much dryer clothes, approximately 30% more drying time). 1. The Dryness Level settings cannot be changed while the dryer is running. 2. Press and hold the DRYNESS LEVEL button for 5 seconds. The dryer will beep, and “CF” will be displayed for 1 second followed by the current drying setting. 3. To select a new drying setting, press the DRYNESS LEVEL button again until the desired drying setting is shown. NOTE: While cycling through the settings, the current setting will not flash, but the other settings will flash. 4. Press START to save the drying setting. The drying setting you selected will become your new preset drying setting for all Auto Dry cycles.

Temperature Press TEMPERATURE until the desired temperature setting glows. Temperature modifiers cannot be used with the Auto Cycles or with the Air Fluff cycle.

Page 24 of the Kenmore 8789 user manual — End of Cycle Signal
Page 24 · click to enlarge
Page 24
2. Place dryer rack over the bottom of the dryer door opening. Rest the back wire on the dryer back ledge. Push down on the frame front to secure over lint screen.

End of Cycle Signal

End of Cycle Signal The End of Cycle Signal produces an audible sound when the drying cycle is finished. Promptly removing clothes at the end of the cycle reduces wrinkling.

3. Place wet items on top of the rack. Allow space around items for air to circulate. The rack does not move, but the drum will rotate. Make sure items do not hang over the edges or between rack grille.

Press CYCLE SIGNAL to adjust the sound level or turn off the signal. NOTE: When WRINKLE GUARD® is selected and the End of Cycle Signal is on, a tone sounds every 5 minutes until the clothes are removed, or WRINKLE GUARD® ends.

4. Close the door. 5. Rotate the dial to the Air Fluff cycle or press Timed Dry. Select a drying time by pressing MORE TIME or LESS TIME. Press TEMPERATURE until the desired temperature glows. Items containing foam, rubber or plastic must be dried on a clothesline or by using the Air Fluff cycle. Refer to the following table. 6. When Air Fluff is selected, the Estimated Time Remaining display shows the default time. You can change the actual time in the cycle by pressing More Time or Less Time. 7. Start the dryer. NOTE: Check the lint screen and remove any lint accumulated from items dried on the rack after the cycle is finished.

TUMBLE FREE™ Heated Dryer Rack The dryer rack is shipped in place in your dryer. Remove and discard any packing material before use. Use the TUMBLE FREE™ Heated Dryer Rack for items that you do not want to tumble dry, such as sweaters. When you use the heated dryer rack, the heated air inside the dryer flows in a concentrated pattern to allow efficient and uniform drying. The dryer rack is recommended for use with the Air Fluff cycle or with Timed Dry cycles. The dryer rack cannot be used with Auto cycles. To use the heated dryer rack: Do not remove the lint screen. 1. Open dryer door.

Dryer Rack Cycle Temp. Time*

Wool Sweaters Block to shape and lay flat on the rack

Timed Dry Low 60

Stuffed toys or pillows Cotton or polyester fiber filled

Timed Dry Low 60

Stuffed toys or pillows Foam rubber filled

Air Fluff Air Only (no heat)

Sneakers or canvas shoes

Air Fluff Air Only (no heat)

*Reset cycle to complete drying if needed. NOTE: You must remove rack for normal tumbling. To remove the dryer rack, lift it straight up and out of the dryer.

Page 25 of the Kenmore 8789 user manual — Vacation care
Page 25 · click to enlarge
Page 25

DRYER CARE

To wash 1. Roll lint off the screen with your fingers. 2. Wet both sides of lint screen with hot water. 3. Wet a nylon brush with hot water and liquid detergent. Scrub lint screen with the brush to remove residue buildup.

Cleaning the Dryer Location Keep dryer area clear and free from items that would obstruct the flow of combustion and ventilation air.

Kenmore 8789 — DRYER CARE diagram (page 25)
Fig. 30
4. Rinse screen with hot water. 5. Thoroughly dry lint screen with a clean towel. Replace screen in dryer.

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Cleaning the Dryer Interior

Failure to do so can result in death, explosion, or fire.

To clean dryer drum 1. Make a paste with powdered laundry detergent and very warm water. 2. Apply paste to a soft cloth. OR

Cleaning the Lint Screen

Every load cleaning The lint screen is located in the door opening of the dryer. The control panel has an indicator light to remind you to clean the lint screen before each load. A screen blocked by lint can increase drying time. To clean 1. Pull the lint screen straight up. Roll lint off the screen with your fingers. Do not rinse or wash screen to remove lint. Wet lint is hard to remove.

Apply a liquid, nonflammable household cleaner to the stained area and rub with a soft cloth until all excess dye and stains are removed.

3. Wipe drum thoroughly with a damp cloth. 4. Tumble a load of clean cloths or towels to dry drum. NOTE: Garments that contain unstable dyes, such as denim blue jeans or brightly colored cotton items, may discolor the dryer interior. These stains are not harmful to your dryer and will not stain future loads of clothes. Dry unstable dye items inside out to avoid dye transfer.

Removing Accumulated Lint

From Inside the Dryer Cabinet Lint should be removed every 2 years, or more often, depending on dryer usage. Cleaning should be done by a qualified person.

2. Push the lint screen firmly back into place. IMPORTANT:

From the Exhaust Vent Lint should be removed every 2 years, or more often, depending on dryer usage.

  • Do not run the dryer with the lint screen loose, damaged, blocked, or missing. Doing so can cause overheating and damage to both the dryer and fabrics.

Vacation and Moving Care

  • If lint falls off the screen into the dryer during removal, check the exhaust hood and remove the lint. See “Venting Requirements.”

Vacation care

As needed cleaning Laundry detergent and fabric softener residue can build up on the lint screen. This buildup can cause longer drying times for your clothes, or cause the dryer to stop before your load is completely dry. The screen is probably clogged if lint falls off while the screen is in the dryer. Clean the lint screen with a nylon brush every 6 months, or more frequently, if it becomes clogged due to a residue buildup.

Operate your dryer only when you are at home. If you will be on vacation or not using your dryer for an extended period of time, you should: 1. Unplug dryer or disconnect power. 2. Clean lint screen. See “Cleaning the Lint Screen.”

Page 26 of the Kenmore 8789 user manual — Dryer displaying code message
Page 26 · click to enlarge
Page 26

Moving care

Changing the Drum Light The dryer light automatically turns on inside the dryer drum when you open the door.

For power supply cord-connected dryers: 1. Unplug the power supply cord. 2. Make sure leveling legs are secure in dryer base. 3. Use masking tape to secure dryer door. For direct-wired dryers:

To change the drum light 1. Unplug dryer or disconnect power. 2. Open the dryer door. Locate the light bulb cover on the back wall of the dryer. Remove the screw located in the lower right corner of the cover. Remove the cover.

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

3. Turn bulb counterclockwise. Replace the bulb with a 10-watt appliance bulb only. Replace the cover and secure with the screw. 4. Plug in dryer or reconnect power.
1. Disconnect power. 2. Disconnect wiring. 3. Make sure leveling legs are secure in dryer base. 4. Use masking tape to secure dryer door.

TROUBLESHOOTING

First try the solutions suggested here and possibly avoid the cost of a service call...

Dryer Operation

Dryer will not run

Unusual sounds

  • Has a fuse blown, or has a circuit breaker tripped? There may be 2 fuses or circuit breakers for the dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped. Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician.
  • Has the dryer had a period of non-use? If the dryer hasn’t been used for a while, there may be a thumping sound during the first few minutes of operation.
  • Is a coin, button, or paper clip caught between the drum and front or rear of the dryer? Check the front and rear edges of the drum for small objects. Clean out pockets before laundering.
  • Is the correct power supply available? Electric dryers require 240-volt power supply. Check with a qualified electrician.
  • Are the four legs installed, and is the dryer level front to back and side to side? The dryer may vibrate if not properly installed. See the Installation Instructions.
  • Was a regular fuse used? Use a time-delay fuse.
  • Is the dryer door firmly closed?
  • Is the clothing knotted or balled up? When balled up, the load will bounce, causing the dryer to vibrate. Separate the load items and restart the dryer.
  • Was the Start button firmly pressed? Large loads may require pressing and holding the Start button for 2-5 seconds.

Dryer displaying code message

No heat

  • “PF” (power failure), check the following: Was the drying cycle interrupted by a power failure? Press and hold START to restart the dryer.
  • Has a fuse blown, or has a circuit breaker tripped? The drum may be turning, but you may not have heat. Electric dryers use 2 fuses or circuit breakers. Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician.
  • “F” Variable (F1, F2, F20) service codes: Call for service.

Electrical Shock Hazard

Page 27 of the Kenmore 8789 user manual — Odors
Page 27 · click to enlarge
Page 27

Dryer Results

  • Is the dryer located in a closet? Closet doors must have ventilation openings at the top and bottom of the door. The front of the dryer requires a minimum of 1" (2.5 cm) of airspace, and, for most installations, the rear of the dryer requires 5" (12.7 cm). See “Installation Instructions.”

Clothes are not drying satisfactorily, drying times are too long, or load is too hot

  • Is the lint screen clogged with lint? Lint screen should be cleaned before each load.
  • Has an air dry cycle been selected? Select the right cycle for the types of garments being dried. See “Modifiers.”
  • Is the load too large and heavy to dry quickly? Separate the load to tumble freely.

Cycle time too short

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Use two or more people to move and install dryer.

Failure to follow these instructions can result in death or fire.

Failure to do so can result in back or other injury.

  • Is the automatic cycle ending early? The load may not be contacting the sensor strips. Level the dryer.
  • Is the exhaust vent or outside exhaust hood clogged with lint, restricting air movement? Run the dryer for 5-10 minutes. Hold your hand under the outside exhaust hood to check air movement. If you do not feel air movement, clean exhaust system of lint or replace exhaust vent with heavy metal or flexible metal vent. See “Venting Requirements.”

Change the dryness level setting on Automatic Cycles. Increasing or decreasing the dryness level will change the amount of drying time in a cycle.

Do not use a dryer rack with an automatic cycle.

  • Are fabric softener sheets blocking the lint screen grille? Use only one fabric softener sheet, and use it only once.

Lint on load

  • Is the exhaust vent the correct length? Check that the exhaust vent is not too long or has too many turns. Long venting will increase drying times. See “Plan Vent System.”
  • Is the lint screen clogged? Clean lint screen. Check for air movement.

Stains on load or drum

  • Is the exhaust vent diameter the correct size? Use 4" (10.2 cm) diameter vent material.
  • Was dryer fabric softener properly used? Add dryer fabric softener sheets at the beginning of the cycle. Fabric softener sheets added to a partially dried load can stain your garments.

Drum stains are caused by dyes in clothing (usually blue jeans). This will not transfer to other clothing.

Loads are wrinkled

  • Was the load removed from dryer at the end of the cycle?

Keep flammable materials and vapors, such as gasoline, away from dryer.

  • Was the dryer overloaded? Dry smaller loads that can tumble freely.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Odors

Failure to do so can result in death, explosion, or fire.

  • Have you recently been painting, staining or varnishing in the area where your dryer is located? If so, ventilate the area. When the odors or fumes are gone from the area, rewash and dry the clothing.
  • Is the dryer located in a room with temperature below 45ºF (7ºC)? Proper operation of dryer cycles requires temperatures above 45ºF (7ºC).
  • Is the dryer being used for the first time? The new electric heating element may have an odor. The odor will be gone after the first cycle.

Fire Hazard · Excessive Weight Hazard · Explosion Hazard

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Kenmore 8789

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Kenmore 8789

Be the first to ask — other owners or our team will answer.

Original document

Kenmore 8789 manual PDF

56 pages·1.7 MB·Clothes Dryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…