

Oasis
Electric Dryer
Secadora el_ctrica
Models/Modelos 110.6705_, 6706_, 6707_ = color number/n_mero de color
W10035160 Sears Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com
®



DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
When installed, operated and maintained according to all instructions supplied with the product, if this appliance fails due to a defect in material or workmanship within one year from the date of purchase, call 1-800-4-MY-HOME ®to arrange for free repair.
Customer's sole and exclusive remedy under this limited warranty shall be product repair as provided herein. Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. Sears shall not be liable for incidental or consequential damages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, or limitations on the duration of implied warranties of merchantability or fitness, so these exclusions or limitations may not apply to you.
If this appliance is used for other than private family purposes, this warranty applies for only 90 days from the date of purchase. THIS WARRANTY COVERS ONLY DEFECTS IN MATERIAL AND WORKMANSHIP. SEARS WILL NOT PAY FOR:
This warranty applies only while this appliance is used in the United States and Canada.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co. Dept. 817WA, Hoffman Estates, IL 60179 Sears Canada Inc. Toronto, Ontario, Canada M5B 2B8
In the space below, record your complete model number, serial number, and purchase date. You can find this information on the model and serial number label located on the product.
Have this information available to help you obtain assistance or service more quickly whenever you contact Sears concerning your appliance. Model number
Save these instructions and your sales receipt for future reference.
Serial number · Purchase date


Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING." These words mean:
You can be killed or seriously injured if you don't immediately follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
[] Read all instructions before using the dryer.
[] Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.
[] Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
[] Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry- cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
[] Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
[] Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials. [] Clean lint screen before or after each load.
[] Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.
[] Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.
[] Before the dryer is removed from service or discarded, remove the door to the drying compartment.
[] Do not reach into the dryer if the drum is moving.
[] The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.
[] Do not install or store the dryer where it will be exposed to the weather.
[] See installation instructions for grounding requirements.
[] Do not tamper with controls.
SAVE THESE iNSTRUCTiONS


Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Keep flammable materials and vapors, such as gaso(ine, away from dryer.
wire installations) • Tape measure
Place dryer at least 18 inches (46 cm) above the floor for a garage installation.
Parts supplied: Remove parts package from dryer drum. Check that all parts were included.
Failure to do so can result in death, explosion, or fire.
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements."
Parts needed: Check local codes, check existing electrical supply and venting and see "Electrical Requirements" and "Venting Requirements" before purchasing parts.
A sturdy floor to support the total weight (dryer and load) of 200 Ibs (90.7 kg). The combined weight of a companion appliance should also be considered.
Mobile home installations require metal exhaust system hardware available for purchase from your local Sears store or Sears Service Center. For further information, please call 1-800-4-MY-HOME ®(1-800-469-4663}.
A level floor with a maximum slope of 1" (2.5 cm) under entire dryer.
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.
Explosion Hazard · You will need · 4 leveling legs


Companion appliance spacing should also be considered.
The location must be large enough to allow the dryer door to open fully.
Additional spacing is required if you exhaust out the rear of the dryer to either the right or left side.
31,, _.6 cm)
48in.2. (310cm2_ - • _
°._212__
18"*_ (45.7cm)
II LM1,max."
24in.2.
29"_ I_1" -_11"*t_29,_"_1 5"
(2.5cm)
(73.7crn) (2.5crn) (2,5crn)(74.3crn)(12.7crn) A B
A. Recessed area
B. Side view - closet or confined area C. Closet door with vents
* Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See "Venting Requirements."
Installation spacing for recessed area or closet installation The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:
Mobile Home - Additional Installation Requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).
Mobile home installations require:
Additional clearances might be required for wall, door and floor moldings.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.


It is your responsibility • To contact a qualified electrical installer.
If your outlet looks like this:
[] To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.
The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
4-wire receptacle (!4-30t:?)
Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.
A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
If your outlet looks like this:
[] Do not use an extension cord.
[] If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
3-wire receptacle (10-30t:?)
Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.
To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
[] If local codes do not permit the connection of a neutral ground wire to the neutral wire, see "Optional 3-wire connection" section.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:
This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.
[] Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.
[] 10-gauge solid copper wire (do not use aluminum).
[] At least 5 ft (1.52 m) long.
[] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.
[] For a permanently connected dryer: This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:
[] A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
[] A UL listed strain relief.
Electrical Connection


Direct Wire
Use a new UL listed 30 amp power supply cord.
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Securely tighten aii electrical connections.
Failure to do so can result in death, fire, or electrical shock.
Failure to do so can result in death, fire, or electrical shock.
Remove the screws from a s/4" (1.9 cm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws just enough to hold the two clamp sections together.
E F
/ t ........................................... C
A. Terminal block cover B. Hold-down screw
C. External ground conductor screw D. Center, silver-colored terminal block screw E. Neutral ground wire F. Hole below terminal block opening
A. Strain relief tab pointing up B. Hole below terminal block opening C. Clamp section
D. Strain relief tab pointing down
Fire Hazard · Fire Hazard


Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
4-wire receptacle A UL listed, 4-wire connection:
(NEMA type 14-30R) 120/240-volt Power Supply
minimum, Cord 30-amp, dryer power supply cord*
4-wire direct A fused 4-wire connection: disconnect or Direct Wire
(12.7 crn)
3-wire receptacle A UL listed, 3-wire connection:
Unscrew the removable conduit connector and any screws from a 3/4"(1.9 cm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening. Reaching inside the terminal block opening, screw the removable conduit connector onto the strain relief threads.
(NEMA type 10-30R) 120/240-volt Power Supply
30-amp, dryer power supply cord*
3-wire direct A fused 3-wire connection:
disconnect or Direct Wire
* If local codes do not permit the connection of a cabinet-ground conductor to the neutral wire, go to "Optional 3-wire connection" section.
A. Removable conduit connector
B. Hole below terminal block opening C. Strain relief threads
Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.
A. 4-wire receptacle (NEMA type 14-30R)
B.4-prong plug C.Ground prong D.Neutral prong
E.Spade terminals with upturned ends F. _" (1.9 cm) UL listed strain relief G.Ring terminals
Now complete installation following instructions for your type of electrical connection:
3-wire (if 4-wire is not available)


Remove center silver-colored terminal block screw.
Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver-colored terminal block screw. Tighten screw.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
A
Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5" (12.7 cm). Cut 11/2'' (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends of wires into a hook shape.
A. Neutral ground wire B. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw. C. Center silver-colored terminal block screw
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
D. Neutral wire (white or center wire)
E. 3/4"(1.9 cm) UL fisted strain relief
Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.
Remove center silver-colored terminal block screw.
Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.
B
A. External ground conductor screw B. Neutral ground wire C. Ground wire (green or bare) of power supply cord D. 3A,,(1.9 cm) UL listed strain refief E. Center silver-colored terminal block screw
E Neutral wire (white or center wire)
Connect the other wires to outer terminal block screws. Tighten screws.
A. Neutral ground wire B. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw. C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E. 3/4"(1.9 cm) UL listed strain relief


Loosen or remove center silver-colored terminal block screw.
Connect neutral wire (white or center wire) of power supply cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.
A. External ground conductor screw B. Neutral ground wire C. Ground wire (green or bare) of power supply cord D. 3_,,(1.9 cm) UL Iisted strain relief
A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E. Center silver-colored terminal block screw
E. _" (1.9 cm) UL Iisted strain relief
F Neutral wire (white or center wire)
Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws. !! !!
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 31/2'' (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape.
A. 3-wire receptacle (NEMA type 10-30R) B. 3-wire plug C. Neutral prong D. Spade terminals with upturned ends E. _" (1.9 cm) UL Iisted strain relief E Ring terminals G. Neutral wire (white or center wire)


When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire.
Loosen or remove center silver-colored terminal block screw.
Place the hooked end of the neutral wire (white or center wire) of direct wire cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.
sJ J_
A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire) E. _" (1.9 cm) UL listed strain relief E Grounding path determined by a qualified electrician
A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw
Connect the other wires to outer terminal block screws. Tighten screws.
D. Neutral wire (white or center wire) E. _" (1.9 cm) UL Iisted strain relief
Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws. !! !!
6, You have completed your electrical connection. Now go to "Venting Requirements."
Optional 3-wire connection · 3, · 3,


Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death or fire.
The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
Recommended hood styles are shown here.
If this is a new vent system
Vent material • Use a heavy metal vent. Do not use plastic or metal foil vent.
(10.2 cm)
A. Louvered hood style
B. Box hood style
The angled hood style (shown here) is acceptable.
4" (lO.2 cm) heavy metal exhaust vent
DURASAFF Mvent products can be purchased from your dealer. For further information, please call f-800-4-MY-HOME ®(1-800-469-4663} or visit our website at www.sears.com
(10.2 cm)__
An exhaust hood should cap the vent to keep rodents and insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).


Improper venting can cause moisture and lint to collect indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.
[] Housecleaning problems and health problems.
A. Standard rear offset exhaust installation B. Rear exhaust installation to left or right side
Choose your exhaust installation type
Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
B
/
A
c. Bottom exhaust installation D.Over-the-top installation (alsoavailable with one
A. Dryer E. Clamps B. Elbow E Rigid metal or flexible metal vent
C, Wall G. Vent length necessary to connect D, Exhaust hood elbows H. Exhaust outlet
Optional exhaust installations Venting systems come in many varieties. Select the type best for your installation.
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.
Cover unused exhaust hole with the following kit:
Contact your local dealer.
Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.
This dryer can be converted to exhaust out the bottom. If you prefer, you may contact your local dealer to have the dryer converted. This dryer can also be exhausted from the rear to either the right or left side. Optional kits for these exhaust installations are needed. Refer to the manufacturer's instructions for kit installation instructions.


Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
Determine vent length and elbows needed for best drying performance
The Vent system chart provides venting requirements that will help to achieve the best drying performance.
Examine the leveling legs. Find the diamond marking.
Vent system chart NOTE: Bottom exhaust performance is equivalent to adding two elbows. To determine maximum exhaust length, add two elbows to the chart.
Number of Type of Box or Angled g0° turns vent Louvered hoods or elbows hoods
0 Rigid metal 64 ft (20 m) 58 ft (17.7 m) Flexible metal 36 ft (11 m) 28 ft (8.5 m)
1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m) Flexible metal 31 ft (9.4 m) 23 ft (7 m)
2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m) Flexible metal 27 ft (8.2 m) 19 ft (5.8 m)
3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m) Flexible metal 25 ft (7.6 m) 17 ft (5.2 m)
4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m) Flexible metal 23 ft (7 m) 15 ft (4.6 m)
Determine vent path · Excessive Weight Hazard


Check the levelness of the dryer. Check levelness first side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for levelness.
You can change your door swing from a right-side opening to a left-side opening, if desired.
Remove the door assembly
B
.A
A. Door strike B. Cosmetic screw
A. Loosen these screws. B, Remove these screws.
Remove the dryer door and the hinges by lifting upward on the door. Lay the door on a flat, protected surface, with the inside of the door facing up. Remove remaining 2 loose screws from dryer front panel.
Replace the 4 screws in the same holes.


Hang door by placing screw heads into top slotted holes of hinges and slide door down. Align bottom screw holes in hinge and door. Install two bottom screws. Tighten all hinge screws.
,.-1
Install the 2 hinges to the front panel of the dryer using 4 screws. Use the non-slotted side to attach the hinge to the front panel.
Install screws in the top hinge holes in the door. Do not tighten screws. Leave approximately W' (5 mm) of screw exposed.
f0. Test dryer operation by selecting a Timed Dry heated cycle and starting the dryer. For this test, do not select the Air Only modifier.
If the dryer will not start, check the following:
A. Install these screws first.
If you do not feel heat, turn off the dryer and check the following:


STATUS
MODIFIERS
b _mal E×_ Low
Keep flammable materials and vapors, such as gasoline, away from dryer.
No washer can completely remove oil.
Do not dry anything that has ever had any type of oil on it (including cooking oils).
Do not dry anything that has ever had anything flammable on it (even after washing).
Items containing foam, rubber, or plastic must be dried on a clothesline or by using an Air Cycle.
Failure to follow these instructions can result in death, explosion, or fire.
Failure to follow these instructions can result in death or fire.
Press POWER.
Select an Auto Dry Cycle.
This booklet covers several different models. Your dryer may not have all of the cycles and features described. •
Select DRYNESS LEVEL to adjust how dry you want the load. As the cycle runs, the control senses the dryness of the load and adjusts the time automatically for the selected dryness level.
Follow these basic steps to start your dryer. Please refer to specific sections of this manual for more detailed information.
The default dryness setting is Normal when an Auto Dry Cycle is selected. You can select a different dryness level, depending on your load, by pressing DRYNESS LEVEL and choosing More, Normal or Less. Selecting More, Normal or Less automatically adjusts the dryness level at which the dryer will shut off. Once a dryness level is set, it cannot be changed without stopping the cycle. Select the desired Options.
NOTE: A default time is displayed when an Auto Dry Cycle is selected. During the first few minutes of the drying process, the cycle time may automatically vary from the default time based on the size and fabric type of the load. Toward the end of the drying process, the estimated time display will adjust again, showing the final drying time.
To make changes during an Auto Dry Cycle:


Adjust Dryness Level.
To stop or pause your dryer at any time Open the door or press STOP once. Press STOP twice to cancel a cycle.
To restart the dryer Close the door. Press START until dryer starts.
Auto Dry Cycles take the guesswork out of drying time and enhance fabric care. The amount of time that is displayed is the estimated time remaining in the cycle. use a Timed Cycle
Select a Timed Cycle.
Select the correct cycle and dryness leve( or temperature for your load. If an Auto Dry Cycle is running, the display shows the estimated cycle time when your dryer is automatically sensing the dryness level of your load. If a Timed Cycle is running, the display shows the exact number of minutes remaining in the cycle.
Press the TIME ADJUST (More Time or Less Time) buttons until the desired drying time is displayed. Press MORE TIME or LESS TIME once and the time will change by 1-minute intervals. Press and hold MORE TIME or LESS TIME and the time will change by 5-minute intervals.
Cool Down tumbles the load without heat during the last few minutes of all cycles. Cool Down makes the loads easier to handle and reduces wrinkling. The length of the Cool Down depends on the load size and dryness level.
Drying tips • Follow care label directions when they are available.
Cycle tips • Dry most loads using the preset cycle settings.
(OPTIONAL STEP) If desired, press CYCLE SIGNAL. A signal will sound to alert you when a cycle ends. For more details, see "Cycle Signal." Press START. Be sure the door is closed.


Follow the progress of your dryer with the drying Status indicator lights.
Select the drying cycle that matches the type of load you are drying. See Auto or Timed Preset Cycle Settings charts.
AUTO DRY CYCLES
Towels Normal \ /
Timed _i - Ultra
Damp The Damp light illuminates in an Auto Dry Cycle when the laundry is approximately 80% dry or suitable for ironing. Damp Dry Signal beeps, if selected. See "Options."
Auto Dry Cycles allow you to match the cycle to the load you are
drying. See the following Auto Preset Cycle Settings chart. Each cycle dries certain fabrics at the recommended temperature. A sensor detects the moisture in the load and automatically adjusts the drying time for optimal drying.
The Cool Down light illuminates during the cool down part of the cycle. Laundry cools for ease in handling.
Clothes Dry The Clothes Dry light illuminates when the drying cycle is finished. This indicator stays on during WRINKLE GUARD ®.
Heavy Duty Use this cycle to get high heat for heavyweight mixed loads, cottons and jeans.
Use this cycle to get high heat for drying heavy fabrics such as towels, sheets or cottons.
The WRINKLE GUARD ®light illuminates when this option is selected. This indicator stays on during WRINKLE GUARD_L
Use this cycle to get medium heat for drying sturdy fabrics such as work clothes.
The Check Lint Screen light reminds you to check the lint screen. The light illuminates when the user selects a cycle. It goes out when the door is opened, Start is pressed, or after 5 minutes elapses.
Use this cycle to get low heat for drying no-iron fabrics, such as sport shirts, casual business clothes and permanent press blends.
Indicator lights Other indicator lights show Cycle, Options, Modifiers and Cycle Signal settings selected. The display shows the estimated or actual time remaining.
Use this cycle to get extra-low heat to gently dry items such as lingerie, blouses or washable knit fabrics.


Auto Preset Cycle Settings Follow care label directions.
Timed Cycles Default Default Time* Load Type Temperature (Minutes)
Auto Dry Cycles Temperature Time* Load Type (Minutes)
TIMED DRY High 40 Heavyweight, bulky items, blankets, work clothes
HEAVY DUTY High 50 Heavyweight mixed loads, cottons, jeans
EXPRESS DRY TM High 23 Small loads
COTTON/TOWELS High 45 Towels, sheets, cottons
* Default times are remembered from the previous cycle.
NORMAL Medium 40 Corduroys, work clothes
CASUAL Low 35 Business casual clothes, permanent press, synthetics
Use the Dryness Level Modifier to select dryness levels for the Auto Dry Cycles. Press Dryness Level until the desired Dryness Level setting illuminates.
ULTRA DELICATE/ Extra-Low 25 DELICATE Lingerie, blouses, washable knit fabrics
The preset dryness setting is Normal when an Automatic Cycle is selected. You can select a different dryness level, depending on your load, by pressing Dryness Level and choosing More, Normal or Less. Selecting More, Normal or Less automatically adjusts the dryness level at which the dryer will shut off. Once a dryness level is set, it cannot be changed without stopping the cycle.
* Estimated Time with Auto Dry Level (Normal) setting, Time will vary depending on load type and load size.
Use Timed Cycles to select a specific amount of drying time and a drying temperature. When a Timed Cycle is selected, the Estimated Time Remaining display shows the actual time remaining in your cycle. You can change the actual time in the cycle by pressing the TIME ADJUST (More Time or Less Time) buttons. See "Changing Cycles, Modifiers and Options."
Timed Dry Use this cycle to complete drying if items are still damp after an Auto Dry Cycle. Timed Dry is also useful for drying heavyweight and bulky items, such as blankets and work clothes. Lightweight garments, such as exercise wear, can be dried using Timed Dry on a low temperature setting.
Use the Temperature Modifier to select temperatures for the Timed Cycles. Press Temperature until the desired temperature setting illuminates.
EXPRESS DRY TM Use this cycle for drying small loads or loads that need a short drying time.


WRINKLE GUARD _ (30, 60, 90, 150 minutes) WRINKLE GUARD _ helps smooth out wrinkles that may form when clothes are not removed promptly at the end of a cycle. During this option, the dryer stops tumbling and then tumbles again for a brief period without heat when pressed.
Use the Air Dry Modifier for items that require drying without heat such as rubber, plastic and heat-sensitive fabrics. This table shows examples of items that can be dried using Air Dry.
Type of Load Time* (Minutes)
Foam rubber - pillows, padded bras, stuffed toys 20 - 30
Plastic - Shower curtains, tablecloths 20 - 30
Rubber-backed rugs 40 - 50
Olefin, polypropylene, sheer nylon 10 - 20
*Reset cycle to complete drying, if needed.
When using Air Dry • Check that coverings are securely stitched.
Cycle Signal The Cycle Signal produces an audible sound when the drying cycle is finished. Promptly removing clothes at the end of the cycle reduces wrinkling.
You can customize your cycles by selecting options.
Press CYCLE SIGNAL VOLUME until the desired volume (Loud or Soft) is selected. On some models, press CYCLE SIGNAL to turn the Cycle Signal On or Off.
On Loud Off Soft
W,h, kle _u_r_ go
Cycle Signal Cycle Signal Volume
Drum Light On some models, you may select Drum Light to turn on the light inside the dryer drum. During a cycle, if Drum Light is selected, the drum light turns on and will remain on until DRUM LIGHT is pressed again, the door is open and closed, or the door is left open for 5 minutes.
When the dryer is not running, the drum light will turn on when DRUM LIGHT is pressed or the dryer door is opened, and it will remain on until the dryer door has been open for 5 minutes, the dryer door is closed or DRUM LIGHT is pressed again.
You can change Auto and Timed Cycles, Modifiers and Options anytime before pressing Start. • Three short tones sound if an unavailable combination is selected. The last selection will not be accepted.
Press DRUM LIGHT at any time to turn the drum light ON or OFR
Damp Dry Signal Select the Damp Dry Signal to alert you that your clothes are approximately 80% dry or suitable for ironing. This is useful when you want to remove lightweight items in a mixed load to avoid overdrying or remove partially dry items that may need ironing.
Changing Cycles after pressing Start 1. Press STOP twice.
The DAMP DRY SIGNAL is useful when drying bedsheets/linens in a mixed load. When the signal goes off, open the door to stop the dryer, rearrange the load inside the dryer, close the door and restart the dryer to finish the drying cycle. Rearranging the load will aid in the drying process.
Changing Modifiers and Options after pressing Start You can change a Modifier or Option anytime before the selected Modifier or Option begins. 1. Press STOP once.
Air Dry · Drum Lght


Changing the Preset Dryness Level Settings If all your loads on all Auto Dry cycles are consistently not as dry as you would like, you may change the preset Dryness Level settings to increase the dryness, This change will affect all of your Auto Dry cycles.
Your Dryness Level settings can be adjusted to adapt to different installations, environmental conditions or personal preference, There are 3 drying settings: 1 (factory preset dryness level), 2 (slightly dryer clothes, approximately 15% more drying time) and 3 (much dryer clothes, approximately 30% more drying time).
Suggested Items for Rack Cycle Suggested Drying Setting Time* (Minutes)
The dryer rack was shipped in the dryer drum.
Use the dryer rack for items that you do not want to tumble dry, such as sweaters.
Washable wool items Low 20 (block to shape and lay fiat on rack)
Use Timed Dry to select the desired time.
Stuffed toys or pillows Low 30 (cotton or polyester fiber filling)
To use the dryer rack: Do not remove the lint screen.
Stuffed toys Air Dry 50 (foam rubber filled)
Galoshes (rubber) Air Dry 20
Foam rubber pillows Air Dry 50
Tennis shoes Air Dry 20
*Reset time as needed to complete drying.


Oe !_n nc tke D/_,eu oc_sl o__}
Keep dryer area clear and free from items that would obstruct the flow of combustion and ventilation air.
As needed cleaning Laundry detergent and fabric softener residue can build up on the lint screen. This buildup can cause longer drying times for your clothes, or cause the dryer to stop before your load is completely dry. The screen is probably clogged if lint falls off while the screen is in the dryer.
Clean the lint screen with a nylon brush every 6 months, or more frequently, if it becomes clogged due to a residue buildup. To wash
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor for a garage installation.
Failure to do so can result in death, explosion, or fire.
Every load cleaning The lint screen is located in the door opening of the dryer. The control panel has an indicator light to remind you to clean the lint screen before each load. A screen blocked by lint can increase drying time. To clean
To clean dryer drum 1. Make a paste with powdered laundry detergent and very warm water.
Apply a liquid, nonflammable household cleaner to the stained area and rub with a soft cloth until all excess dye and stains are removed.
Explosion Hazard · _-- \\


The dryer light automatically turns on inside the dryer drum when you open the door.
From Inside the Dryer Cabinet Lint should be removed every 2 years, or more often, depending on dryer usage, Cleaning should be done by a qualified person.
To change the drum light 1. Unplug dryer or disconnect power.
From the Exhaust Vent
Lint should be removed every 2 years, or more often, depending on dryer usage.
Operate your dryer only when you are at home. If you will be on vacation or not using your dryer for an extended period of time, you should:
For power supply cord-connected dryers: 1. Unplug the power supply cord.
For direct-wired dryers:
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Vacation care · Moving care · Electrical Shock Hazard


First try the solutions suggested here and possibly avoid the cost of a service call...
Has a household fuse blown, or has a circuit breaker tripped? Replace the fuse or reset the circuit breaker. There may be 2 household fuses or circuit breakers for the electric dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped. If the problem continues, call an electrician.
"AF" (dryer is experiencing a low airflow condition): To clear the code, press STOP once and the estimated time remaining countdown will return to the display. "AF" will continue to appear with each cycle until the low airflow condition is resolved.
Try the following: Clean lint screen.
is the correct power supply available? Electric dryers require 240-volt power supply. Check with a qualified electrician.
Check that the vent pipe from the dryer to the wall is clear.
Check at the outside of the home that the vent exhaust hood is not blocked.
Was a regular fuse used? Use a time-delay fuse.
Have your home venting run cleaned professionally.
Is the dryer door firmly closed?
If the problem continues, call for service. To contact Sears Service, call 1-800-4-MY-HOME ®(1-800-469-4663) or see the back page of this manual.
Was the Start button firmly pressed? Large loads may require pressing and holding the Start button for 2-5 seconds.
"F" Variable (F1, F2, F20, etc.) service codes: Call for service. To contact Sears Service, call 1-800-4-MY-HOME ®(1-800-469-4663} or see the back page of this manual.
Has a household fuse blown, or has a circuit breaker tripped? The drum may be turning, but you may not have heat. Electric dryers use 2 household fuses or breakers. Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician.
Clothes are not drying satisfactorily, drying times are too long, or load is too hot
Ifthe dryer hasn't been used for a while, there may be a thumping sound during the first few minutes of operation.
Is a coin, button or paper clip caught between the drum and front or rear of the dryer? Check the front and rear edges of the drum for small objects. Clean out pockets before laundering.
Are the four legs installed, and is the dryer level front to back and side to side? The dryer may vibrate if not properly installed. See "Installation Instructions."
Use a heavy metal vent.
is the clothing knotted or balled up? When balled up, the load will bounce, causing the dryer to vibrate. Separate the load items and restart the dryer.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death or fire.
Is the exhaust vent or outside exhaust hood clogged with lint, restricting air movement? Run the dryer for 5-10 minutes. Hold your hand under the outside exhaust hood to check air movement. If you do not feel air movement, clean exhaust system of lint or replace exhaust vent with heavy metal or flexible metal vent. See "Installation Instructions."
Fire Hazard


Are fabric softener sheets blocking the grille? Use only one fabric softener sheet, and use it only once.
Cycle time too short
Is the exhaust vent the correct length? Check that the exhaust vent is not too long or has too many turns. Long venting will increase drying times. See "Installation Instructions."
Is the exhaust vent diameter the correct size? Use 4" (10.2 cm) diameter vent material.
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
Change the dryness level setting on Auto Dry Cycles. Increasing or decreasing the dryness level will change the amount of drying time in a cycle.
Do not use a dryer rack with an Auto Dry Cycle.
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (46 era) above the floor for a garage installation,
Failure to do so can result in death, explosion, or fire.
Stains on load or drum
Is the dryer located in a room with temperature below 45°F (7°C)? Proper operation of dryer cycles requires temperatures above 45°F (7°C).
Is the dryer located in a closet? Closet doors must have ventilation openings at the top and bottom of the door. The rear of the dryer requires 5" (12.7 cm) of airspace. See "Installation Instructions."
Drum stains are caused by dyes in clothing (usually blue jeans). This will not transfer to other clothing.
Has the Air Only modifier been selected? Select the right temperature for the types of garments being dried. See "Modifiers."
Is the load too large and heavy to dry quickly? Separate the load to tumble freely.
Are all your Auto Dry cycle loads consistently not as dry as you would like? You may change the preset Dryness Level settings to increase dryness for all Auto Dry cycles. See "Changing Cycles, Modifiers and Options."
Is the electric dryer being used for the first time? The new electric heating element may have an odor. The odor will be gone after the first cycle.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.