Model/Modelo: 796. 8147#, 796.9147# Kenmore Elite ® Steam Dryer Secador con vapor
# = color number, numero de color
P/N MFL62512871
Sears Brand Management Corporation Hoffman Estates, IL 60179 U.S.A.
English / Español


Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word DANGER or WARNING. These words mean:
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
moderate injury.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.

BASIC SAFETY PRECAUTIONS
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
CALIFORNIA SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT This act requires the Governor of California to publish a list of substances known to the state to cause cancer, birth defects, or other reproductive harm and requires businesses to warn customers of potential exposure to such substances. Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde, and soot, caused primarily by the incomplete combustion of natural gas or LP fuels. Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be minimized further by properly venting the dryer to the outdoors.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician. This appliance must be connected to a grounded metal, permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance. Electrical shock can result if the dryer is not properly grounded.
This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance must be equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.


SAFETY INSTRUCTIONS FOR STEAM FUNCTIONS
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

KEY PARTS AND COMPONENTS
There are several important components that are referenced in this manual.
A
A
EASY-TO-USE CONTROL PANEL Rotate the cycle selector knob to select the desired dry cycle. Add cycle options or adjust settings with the touch of a button.
B
B
TIME AND STATUS DISPLAY The easy-to-read LED display shows cycle status and estimated time remaining.
CYCLE MODIFIERS Adjust the cycle settings such as temperature and dry level with the touch of a button. NOTE: Not all settings are available for all cycles.
STEAM FEEDER This drawer contains the reservoir for the water used by the dryer to create steam for the STEAM REFRESH cycle and other steam features.
G H
E
CHECK VENT (Duct Blockage Sensing System) The Check Vent (Duct blockage sensing system) detects and alerts you to blockages in the exhaust system that reduce airflow from the dryer. Maintaining clean exhaust system ducts improves operating efficiency and helps minimize service calls, saving you money.

ULTRA-CAPACITY STAINLESS STEEL DRUM WITH DRUM LIGHT The ultra-large stainless steel drum offers superior durability. The drum light can be turned on during a cycle by using the DRUM LIGHT button on the control panel. The light also comes on when the door is opened, if the control is ON.
EASY-ACCESS REVERSIBLE DOOR The wide-opening, see-through glass door provides easy access for loading and unloading. Door swing can be reversed to adjust for installation location.
FRONT-MOUNT LINT FILTER The front-mount lint filter allows for easy access and cleaning between loads.
LEVELING FEET Four leveling feet (two in front, and two in back) adjust to improve dryer stability on uneven floors.

Description Dryer (Gas and Electric) Electrical Requirements Refer to the rating label Gas Requirements* NG: 4–10.5 inches WC (Water Column) Gas Requirements* LP: 8–13 inches WC Dimensions 27 in. (W) X 30 1/4 in. (D) X 38 in. (H), 52 ¼ in. (D with door open) 68.6 cm (W) X 76.7 cm (D) X 96.5 cm (H), 132.7 cm (D with door open) Net Weight Electric : 147 lb. (66.7 kg) Gas : 150.5 lb. (68.3 kg) Drying Capacity IEC 7.4 cu. ft. *Gas Models Only

Standard Installation – Side View

Standard Installation – Front View

4 in. (10 cm)
52 ¼ in. (132.7 cm)
1 in. (2.5 cm)
3" (7.6 cm)

48 sq. in. (310 sq. cm.)
24 sq. in. (155 sq. cm.)
3" (7.6 cm)
Additional instructions for closet installations: The closet door must allow for sufficient airflow. Refer to the diagram above for minimum vent opening requirements. A louvered door is also acceptable.
Vent · Vent


4 in. (10 cm) 30 1/4 in. (76.7 cm)
1 in. (2.5 cm) 27 in. (68.6 cm) 1 in. (2.5 cm)
Use the stacking kit to mount the dryer on top of the washer to save floor space. White = D26 17002 Ginger = D26 17008 Chili Pepper = D26 17009
Use the LP conversion kit for changing the dryer gas connections from natural gas (NG) to propane gas (LP). Part No. 383EEL3002D
Use a pedestal to make laundry easier to reach. White = 796.51022 Ginger = 796.51028 Chili Pepper = 796.51029
Use the side vent kit for venting directly to either side or to the bottom. Gas dryers can only vent to the left. Kit # D26-49670

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
3-prong grounding type wall receptacle
Ensure proper ground exists before use.
3-prong grounding plug

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Make sure that the gas supply to the laundry room is turned OFF and the dryer is unplugged. Confirm that the type of gas available in your laundry room is appropriate for the dryer. Remove the shipping cap from the gas fitting at the back of the dryer. Be careful not to damage the threads of the gas connector when removing the shipping cap. Connect the dryer to your laundry room’s gas supply using a new flexible stainless steel connector with a ⅜ inches NPT fitting. NOTE: DO NOT use old connectors. Securely tighten all connections between the dryer and your laundry room’s gas supply. Turn on the gas supply. Check all pipe connections (both internal and external) for gas leaks with a noncorrosive leak-detection fluid. Proceed to Venting the Dryer.
1/8" NP T Pipe Plug ⅜ in. NPT Gas
Gas Supply Shutoff Valve AGA/CSA-Certified Stainless Steel Flexible Connector

High-Altitude Installations The BTU rating of this dryer is AGA-certified for elevations below 10,000 feet. If your gas dryer is being installed at an elevation above 10,000 feet, it must be derated by a qualified technician or gas supplier.

Electrical Requirements for Electric Models Only
To help prevent fire, electrical shock, serious injury, or death, the wiring and grounding must conform to the latest edition of the National Electrical Code, ANSI/NFPA 70 and all applicable local regulations. Please contact a qualified electrician to check your home’s wiring and fuses to ensure that your home has adequate electrical power to operate the dryer.
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short or overload.
Grounding through the neutral wire is prohibited for: (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral wire.
Three-Wire Power Cord

Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole. Thread a 30-amp, 240-volt, 4-wire, UL-listed power cord with #10 AWG-minimum copper conductor through the strain relief.
Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole. Thread a 30-amp, 240-volt, 3-wire, UL-listed power cord with #10 AWG-minimum copper conductor through the strain relief.

Transfer the neutral grounding wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads (black and red) of the power cord to the outer terminal block screws. Attach the power cord white neutral wire to the cen ter screw of the terminal block. Attach the power cord ground wire to the green ground screw. TIGHTEN ALL SCREWS SECURELY. Reinstall the terminal block access cover.
Attach the two hot leads (black and red) of the power cord to the outer terminal block screws. Attach the power cord neutral (white) wire to the center terminal block screw. Connect the external ground (if required by local codes) to the green ground screw. TIGHTEN ALL SCREWS SECURELY. Reinstall the terminal block access cover.

CHECK YOUR EXHAUST SYSTEM FOR PROBLEMS IMPORTANT!
The most common cause of dryer problems is poor exhaust venting. Before installing your new dryer, check the items listed below to make sure you get the best possible performance. This can save you time and money by reducing cycle times and increasing energy efficiency.
Find your vent hood type in the chart below. Select the row that matches the number of elbows in your dryer duct run. Look to the right of the elbow number for the maximum duct length for your installation. Longer duct length will result in reduced drying performance, longer dry times and increased energy consumption. Extremely long ducts can even shorten the life of the dryer.
DO NOT exceed the maximum length for the vent hood type and number of elbows used.
Maximum length of 4" (10.2 cm )
Elbows Vent Hood Type
diameter rigid metal duct
65 feet (19.8 m)
55 feet (16.8 m)
47 feet (13.7 m)
36 feet (11.0 m)
(10.2 cm) 4"
(10.2 cm)
28 feet (8.5 m)
55 feet (16.8 m)
Only for Short-Run Installations
47 feet (13.7 m)
41 feet (12.5 m)
30 feet (9.1 m)
21/2" (6.35 cm )
22 feet (6.7 m)
Number of 90° · Recommended · 4"



Failure to follow these guidelines will result in poor performance, product failure, and/or result in fire or death.
Verify all ducts and elbows are clean and free from any blockages. Measure duct length. DO NOT exceed the maximum length listed in the Duct Length Chart. Connect dryer exhaust to existing duct.



The swing of the dryer door can be reversed to fit your installation location. WARNING:
Position the dryer in the final location. Place a level across the top of the dryer. All four leveling feet must rest solidly on the floor. Gently push on the top corners of the dryer to make sure that the dryer does not rock from corner to corner.
Open the dryer door. Using a Phillips screwdriver, remove the two latch screws and the latch. Remove the two hole caps, one each above and below the latch by rotating them slightly clockwise. While supporting the weight of the door, remove the four hinge screws. CAUTION: Be sure to support the weight of the door before removing the hinge screws. Carefully turn the door upside down and reinstall it on the opposite side using the screws removed in step 4.
Use a wrench to turn the leveling feet. Turn the leveling foot clockwise to raise the dryer; turn the foot counterclockwise to lower the dryer. Using a level, adjust the feet until the dryer is level from side to side and front to back. Make sure all four feet are in firm contact with the floor. NOTE: If you are installing the dryer on the optional pedestal, the dryer leveling feet should be fully retracted. Use the leveling feet on the pedestal to level the dryer.
Latch Screws Hinge Screws
Latch Screws Hinge Screws
Install the door latch in the opening on the side from which the door was removed using the screws from step 2. Install the hole caps removed in step 3 in the holes above and below the latch where the door was originally mounted. Test the door for proper operation and make sure it latches properly.

Once you have completed the installation of the dryer and it is in its final location, confirm proper operation with the following steps and tests.
Close the dryer door.
Is gas turned on? (Gas models only)
Press the POWER button to turn the dryer on.
Is dryer plugged in? Dryer should always be plugged into the proper outlet.
Turn the cycle selector knob to Normal drying cycle.
Press the START/PAUSE to start the dryer. After three minutes, open the dryer door and check that the air inside is warm.
Gas dryer should use a 120-VAC, 60-Hz. grounded 3-prong outlet.
NOTE: If the air inside the dryer is not warm after three minutes, there may be air in the gas supply line to the dryer, and the gas igniter may turn off before the main burner ignites. When this happens, the igniter will continue to attempt main burner ignition until all air is purged from the line. Once ignition occurs, the air inside the dryer will become warm.
Electric dryer should use a 4-wire connection which is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996.
Checking Venting Vent ductwork should be checked for lint buildup and cleaned at least once per year. If any noticeable reduction in drying performance occurs, check duct for obstructions and blockages.
A 3-wire connection. NOTE: A 3-wire connection is NOT permitted on new construction after January 1, 1996.
Is the dryer transition duct from dryer to wall connected? Make sure the transition duct behind the dryer is properly connected and is not crushed or damaged.
Is dryer level? Once the dryer is in its final location, recheck the dryer to be sure it is level. Make sure it is level front to back and side to side, and that all four leveling feet rest firmly on the floor.
Is the dryer heating normally? Perform the following dryer heating test.



POWER (ON/OFF) BUTTON Press to turn the dryer ON or OFF. Pressing the POWER button during a cycle will cancel that cycle and any settings will be lost.
CYCLE MODIFIER BUTTONS Use these buttons to adjust the settings for the selected cycle. The settings light up above the buttons to show the current selection. The default temperature setting cannot be changed in AUTO DRY cycles. AUTO DRY cycles are modified using the DRY LEVEL button.
CYCLE SELECTOR KNOB The cycle selector knob is used to select the desired dry cycle by rotating the knob in either direction until the desired cycle LED is illuminated. Once the desired cycle has been selected, the standard presets for that cycle will show in the display. These settings can be adjusted using the cycle modifier or option buttons any time before starting the cycle.
TIME AND STATUS DISPLAY The display shows the estimated time remaining for auto cycles and actual time for timed cycles. The status of the cycle is also displayed. The CHECK VENT indicator will illuminate if there is a serious restriction in the exhaust system.
START/PAUSE BUTTON Press this button to start the selected cycle. The dryer will display the estimated time (AUTO DRY) or set time (TIMED DRY) remaining and start tumbling. To pause the cycle at any time, open the dryer door or press START/PAUSE. To resume the cycle where it was stopped, press START/PAUSE again. NOTE: If the dryer has been stopped for more than four minutes, the dryer will turn off automatically.
STEAM FUNCTIONS The STEAM REFRESH cycle uses a swirling jet of steam to refresh clothes. The STATIC SHIELD and IRON READY options are also available for most cycles.
STEAM FEEDER This drawer contains the reservoir for the water used by the dryer to create the steam used for the steam cycle and options. Fill the steam feeder with tap water to take advantage of the power of steam for fresher, static-free fabrics.
OPTION BUTTONS These buttons allow you to select cycle options. Some of the option buttons have secondary functions. The controls can be locked or unlocked by pressing and holding the CONTROL LOCK button for five seconds.


LOAD THE DRYER Load the dryer with the wet laundry from the washer. If the load is extra large, you may need to divide it into smaller loads for proper performance and fabric care.
CLEAN THE LINT FILTER If the lint filter has not already been cleaned, lift out the filter and remove the lint from the last load. This will help ensure the fastest and most efficient drying performance.
TURN ON THE DRYER Press the POWER button to turn ON the dryer. The cycle LEDs will illuminate and a chime will sound.
SELECT A CYCLE Turn the cycle selector knob in either direction until the LED for the desired cycle is illuminated. The preset temperature, dry level, and option settings for that cycle will display.

SELECT CYCLE MODIFIERS Default settings for the selected cycle can now be changed, if desired, using the Temp and Dry Level buttons.
SELECT CYCLE OPTIONS Cycle options can be added using the option buttons (wrinkle guard, static shield, control lock and iron ready).
BEGIN CYCLE Press the START/PAUSE button to begin the cycle. The cycle can be paused at any time by opening the door or by pressing the START/PAUSE button. If the cycle is not restarted within four minutes of being paused, the dryer will shut off and the settings will be lost.
END OF CYCLE When the cycle is finished, the chime will sound. Immediately remove your clothing from the dryer to reduce wrinkling. If WRINKLE GUARD is selected, the dryer will tumble briefly every few minutes to help prevent wrinkles from setting in the clothes.

CYCLE GUIDE
The cycle guide below shows the available options and recommended fabric types for AUTO DRY cycles. *NOTE: The default time and actual time will vary depending on the size of the load and moisture content.
Auto Dry Cycles Auto Dry cycles utilize a sensor that detects moisture levels in the clothes and adjusts the drying time as needed to ensure superior results. The dryer automatically sets the dry level and temperature at the recommended setting for each cycle. The estimated time remaining will be shown in the display.
= available option = default setting

Type Cycle Fabric Type Temperature Dry Level *Time in Min.
Comforter, shirts, trousers 1-5 garments (DO NOT use for delicate fabrics)
Only normal & cotton/towel fabric type (Max 3 lb)

CYCLE GUIDE
The cycle guide below shows the available options and recommended fabric types for TIMED DRY cycles.
Timed Dry Cycles Use Timed Dry cycles to select a specific amount of drying time and the drying temperature. When a TIMED DRY cycle is selected, the display shows the actual time remaining in your cycle. You can change the actual time for the cycle by pressing MORE TIME or LESS TIME. Press and hold the MORE TIME or LESS TIME buttons to rapidly change the time.
= available option = default setting

Type Cycle Fabric Type Temperature Dry Level *Time in Min.
Express Dry For small loads with short drying times
For items that require heat-free drying such as plastics or rubber
For general drying. Time, temperature, and options can be set manually
*Timed Dry is accessed by pressing the Timed Dry button in the Cycle Modifiers field of the of the Control Panel.

Fabric Care Labels Most articles of clothing feature fabric care labels that include instructions for proper care.
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
Dry Normal Permanent Press/ wrinkle resistant
Gentle/ delicate Do not tumble dry Do not dry (used with do not wash)
High Medium Low No heat/air
Group Similar Items For best results, sort clothes into loads that can be dried with the same drying cycle.
Different fabrics have different care requirements, and some fabrics will dry more quickly than others. For best fabric care results, always dry fabrics with similar care requirements together.
CHECK THE LINT FILTER BEFORE EVERY LOAD Every time the dryer is turned on, the CHECK FILTER light will blink as a reminder to make sure the filter is clean. Always make sure the lint filter is clean before starting a new load; a clogged lint filter will increase drying times. To clean, pull the lint filter straight up and roll any lint off the filter with your fingers. Do not rinse or wash the filter to remove lint. Push the lint filter firmly back into place. Always ensure the lint filter is properly installed before running the dryer. Running the dryer with a loose or missing lint filter may damage the dryer and articles in the dryer.
Tumble dry · Heat setting · Lint Filter

TIME AND STATUS DISPLAY
The Time and Status Display shows the cycle time, cycle progress, and vent status. When the dryer is turned on, the display will illuminate.

TIME DISPLAY When a cycle is selected, the display will indicate the default time for that cycle including selected options or adjustments. In AUTO DRY cycles, the time remaining will be estimated and may change during the cycle, depending on the condition of the load. In TIMED DRY, the time displayed will be the actual time remaining.
CHECK VENT INDICATOR (DUCT BLOCKAGE SENSING SYSTEM) The CHECK VENT duct blockage sensing system detects and alerts you to blockages in the ductwork that reduce exhaust flow from the dryer. This light does not indicate any problems with your dryer. If this light blinks, it indicates that your home’s exhaust system has a serious restriction, which is not covered by your dryer’s warranty. Call 1-800-4-MY-HOME® for information regarding duct cleaning services offered through Sears.
CHECK FILTER LIGHT The CHECK FILTER light will blink before each load, as a reminder to check the lint filter. Always clean the lint filter before every cycle.
CONTROL LOCK When CONTROL LOCK is set, all controls are disabled which will allow the dryer to be shut off. When the controls are locked, the dryer can not be operated until the CONTROL LOCK is turned off. If the controls are locked, the CONTROL LOCK LED will illuminate and “CL” will alternate with the cycle time in the display.
CYCLE STATUS INDICATORS This portion of the display shows which stage of the drying cycle is currently under way (DRY, COOLING, or WRINKLE GUARD).
ADD WATER INDICATOR If the steam feeder runs low on water, the ADD WATER light will blink and the cycle will cancel. Refill the steam feeder and then restart the cycle.

CYCLE MODIFIER BUTTONS
Each cycle has default settings that are selected automatically. You may also customize these settings using the cycle modifier buttons. AUTO DRY cycles are designed to properly care for specific fabrics and loads. As a result, not all settings are available for each cycle selection.
TIMED DRY cycles have default settings, but you may also customize the temperature setting and add options. Settings are not limited in most timed dry cycles. Use care when setting options and modifiers for these cycles to prevent damage to your clothing.

TEMP Adjusts the temperature setting from LOW to HIGH. This allows precise care of your fabrics and garments. Press the TEMP button repeatedly to scroll through available settings. Temperature setting is not adjustable in AUTO DRY cycles.
TIMED DRY Allows you to manually select the drying time in 10-minute increments. Use this cycle for small loads or to remove wrinkles. Use the MORE TIME/LESS TIME buttons to increase or decrease the selected drying time in 1-minute increments. Press and hold the MORE TIME or LESS TIME buttons to rapidly change the time.
CHIME Adjusts the volume of the chime or turns off the chime. Press the button repeatedly until the desired volume setting is illuminated.

CYCLE OPTIONS AND SPECIAL FEATURES Your dryer features several additional cycle options and special features to meet your individual needs. For all steam features, see the following pages. WRINKLE GUARD
Selecting this option will tumble the clothes after the cycle ends for a few seconds every few minutes without heat. This option is active for 150 minutes after the end of the cycle, or until the door is opened. This helps prevent wrinkles if the clothes are not removed immediately after the cycle has finished. CONTROL LOCK
Use the DRUM LIGHT button to turn on the light inside the drum during cycle operation.
Use this option to disable the controls. The Control Lock can only be activated during a cycle. All controls will be disabled. Once set, the CONTROL LOCK must be turned off before the controls can be used. After the dryer has shut off, the POWER button will allow the dryer to be turned on, but the controls will remain locked. When the controls are locked “CL” will display alternately with the estimated time remaining. If Wrinkle Guard is not activated when the controls are locked, the LED will blink. Press and hold the WRINKLE GUARD button for five seconds to lock or unlock the controls. MY CYCLE

MY CYCLE allows you to store a customized dry cycle for future use. It allows you to save favorite temperature, dry level, and other options for a cycle, and then recall them at the touch of a button. NOTE: You can only save the customized settings for one cycle at a time. Pressing and holding the MY CYCLE button will overwrite any previously saved cycle. To save a MY CYCLE:
With the dryer door open, slide the rack into the dryer drum.
Make sure the front of the rack is seated properly in the recess on the lint filter housing at the front of the drum. The two rear legs of the rack should be resting on the rear wall just above the drum. Place items to be dried on the rack. Make sure that no parts of the article hang over the edges of the rack, as they might be contacted by the rotating drum, causing noise or damage to the drum or articles. NOTE: Be sure to remove the drying rack after using the RACK DRY cycle.
Press the POWER button to turn on the dryer.
Turn the cycle selector knob to select the desired cycle.
Press the CYCLE MODIFIER button to change the desired setting.
Press the CYCLE OPTION button to add the desired options.
Press and hold the MY CYCLE button.
To recall a MY CYCLE: Press the POWER button to turn on the dryer.
Press the MY CYCLE button. The stored settings will be displayed.
Press the START/PAUSE button to start the cycle. NOTE: MY CYCLE can be adjusted the same as any other cycle. However, once any other button is pressed, the LED will turn off, indicating that the settings are no longer those of your saved cycle. DAMP DRY SIGNAL
If you press the Damp Dry Signal, the dryer will emit a chime when the clothes are just short of completely dry, in case you want to remove them for ironing or hang drying.

STEAM FEATURES
Using the STATIC SHIELD option
This option uses steam late in the drying cycle to reduce the static electricity caused by dry fabrics rubbing together. Change the steam time by pressing the MORE TIME and LESS TIME buttons to display the approximate number of articles in the load: 7, 9, 11, 14, 16 or 18.
Press and hold the STATIC SHIELD button for three seconds to access the Iron Ready function. The IRON READY option provides uniform, properly dampened fabrics for ironing, which can save time and make ironing easier. Change the steam time by pressing the MORE TIME or LESS TIME button, depending on the number of garments in the load: 1, 2, 3, 4, or 5.
Using the STEAM REFRESH cycle The STEAM REFRESH cycle uses the power of steam to quickly reduce wrinkles and odor in fabrics. It brings new life to wrinkled clothes that have been stored for an extended period of time, and it can make heavily wrinkled clothes easier to iron. STEAM REFRESH can also be used to help reduce odors in clothes, such as clothes that were worn in a room where people had been smoking. This cycle can refresh from one to five garments, or one bulky item such as a comforter. There are three settings available. Use 3 for one to three garments and 5 for four or five garments. The
(big) setting should be used for bulky items. Best results are achieved with 70/30 cotton/polyblend fabrics.
Turn the dryer ON and select the STEAM REFRESH cycle.
Select the STATIC SHIELD option, if desired.
The default number of garments is three. Press the MORE TIME or LESS TIME button to adjust the load size, as described above.
Press the START/PAUSE button to start the cycle.

STEAM FEATURES (continued)
Filling the Steam Feeder:
ONLY
MAX
MAX
Pull out the drawer.
Fill the steam feeder with ordinary tap water to the MAX line or until the water touches the filter screen.
Lift out the steam feeder.
Place the steam feeder in the drawer; then push in the drawer until it clicks into place.
Before using a steam cycle, the steam feeder must be filled with water up to the MAX line; make sure that the drawer is completely closed. If the steam feeder runs out of water, the ADD WATER light will blink. If the light blinks, turn the dryer off, refill the feeder, and then restart the steam cycle. When steam is used for the first time, it is possible that the steam feeder may not have enough water and the ADD WATER light will illuminate. Refill the feeder and restart the cycle.


Cleaning the Exterior Proper care of your dryer can extend its life. The outside of the machine can be cleaned with warm water and a mild, nonabrasive household detergent. Immediately wipe off any spills with a soft, damp cloth. IMPORTANT: Do not use cleaning alcohols, solvents, or similar products. NEVER use steel wool or abrasive cleansers because they can damage the surface.
ALWAYS make sure the lint filter is clean before every cycle. The Check Lint Filter Light on the control panel will blink before every cycle to remind you. NOTE: NEVER operate the dryer without the lint filter. To remove lint between cycles:
Open the dryer door.
Cleaning the Interior Wipe around the door opening and seal with a soft, damp cloth to prevent lint and dust buildup that could damage the door seal. Clean the window with a soft cloth dampened with warm water and a mild, nonabrasive household detergent, then wipe dry. NEVER use steel wool or abrasive cleansers; they can scratch or damage the surface.
Pull the lint filter straight up. Roll any lint off the filter with your fingers. Insert lint filter back into dryer. Periodic thorough cleaning: Some fabric softeners can build up on the lint filter over time. This buildup can restrict the airflow through the filter reducing dryer efficiency and lengthening drying times. After removing lint, if the filter looks dark or dirty when held up to the light, follow these steps to clean:
Cleaning Around and Under the Dryer Vacuum lint and dust from around the dryer and underneath it regularly.

Use hot soapy water and a stiff brush to clean the filter. Make sure the filter is completely dry before reinstalling it and using the dryer.

MAINTAINING THE EXHAUST SYSTEM
The most common cause of dryer problems is poor exhaust venting. Poor exhaust venting may result from the following conditions:
Maintaining the Exhaust System Vent ducts should be checked for lint buildup and cleaned at least once per year. If any noticeable reduction in drying performance occurs, check the ducts for obstructions and blockages. If the CHECK VENT indicator illuminates, the exhaust system should be checked immediately for damage or obstructions. The CHECK VENT indicator signals a serious reduction in exhaust airflow which will greatly reduce energy efficiency and increase drying times. Damaged or restricted exhaust systems are not covered by the dryer warranty. Damage to the dryer that is caused by damaged, restricted, or otherwise inadequate exhaust systems is not covered by the dryer warranty. CHECK VENT Indicator The CHECK VENT warning system is designed to help you avoid the reduced performance caused by restrictions in the household exhaust system. The CHECK VENT indicator illuminates to alert you when problems in the system occur, so you can have them repaired. While you should always check and maintain your exhaust system regularly, the CHECK VENT warning system will detect and alert you if serious problems develop in your home’s exhaust system. This includes exhaust systems that are unsatisfactory for any reason including a blockage in the venting, crushed/kinked venting, or venting which exceeds the maximum recommended length requirement as described in the installation section. NOTE: The total length includes the length from the back of the dryer to the outside vent hood, PLUS a factor for every 90° elbow in the exhaust system. For example, if the distance from the back of the dryer to the vent hood is 30 feet, and there are four elbows in the system, then it exceeds the 28 foot maximum length allowed for those conditions as specified in the Duct Length Chart. The CHECK VENT indicator on the control panel will alert you that the exhaust system is not moving enough air from the dryer to the outside. This lack of airflow will lead to long dry times, poor drying and possibly dryer failure. As a reminder, external dryer venting is considered part of your home and is not covered by the product warranty or protection agreements. There are services available for cleaning/maintaining the external venting. Sears provides this service via Sears Carpet, Upholstery, and Duct Cleaning. Call 1-800-661-6594 to schedule duct cleaning service from Sears (if it is available in your area).
CHECK VENT Operation The CHECK VENT system uses components already in the dryer. By monitoring these components over the course of several cycles, the control is able to determine how much restriction there is in the exhaust system. If it detects a high level of restriction, it will turn on the CHECK VENT light to alert you to the condition. The dryer will continue to operate after the light comes on, but you should have the exhaust system cleaned or repaired immediately to avoid longer dry times and higher energy consumption.
IMPORTANT: In order for a dryer to properly and efficiently dry your clothes, it is extremely important that the exhaust system is as short and clean as possible. It MUST be less than the maximum length specifications as outlined in the installation section. It is also very important that you make sure that when the dryer is installed, the exhaust system is clean and clear of any restrictions and is not kinked or crushed. Failure to meet these guidelines will result in long dry times, increased energy consumption and possibly even clothing damage or dryer failure. When exhaust system restrictions become extreme, the CHECK VENT light will blink to alert you to the condition so you can have the exhaust system cleaned or repaired.
To prevent false alarms and for increased reliability, the dryer will monitor the exhaust condition for several loads. If multiple, consecutive cycles exceed the restriction limits, the control will blink the CHECK VENT indicator. A blinking CHECK VENT indicator means the external venting should be checked for potential restrictions as soon as possible. The CHECK VENT indicator will remain active (blinking) until the restriction is resolved AND the control has verified the improved airflow for several cycles. After the exhaust is cleaned or repaired, it will take several cycles for the CHECK VENT indicator to reset and turn off the light.
NOTE: The CHECK VENT indicator is designed to measure performance over several consecutive cycles before activating or deactivating, to avoid false alarms. A very large load, such as a large comforter, could cause the CHECK VENT system to sense that the exhaust system is restricted, but this would not cause the light to blink. However, if several large loads were to run back to back, the CHECK VENT indicator could be activated.

If you experience problems with your dryer, call 1-800-4-MY-HOME®. Only use the Kenmore Connect System feature when instructed to do so by the Kenmore Connect Team. The transmission sounds that you will hear are normal and sound similar to a fax machine. Kenmore Connect cannot be activated unless your dryer is turned on by pressing the POWER button. If your dryer is unable to turn on, then troubleshooting must be done without using Kenmore Connect.
Should you experience any problems with your dryer, it has the capability of transmitting data via your telephone to the Kenmore Connect Team. This gives you the capability of speaking directly to our specially trained technicians. The technician records the data transmitted from your machine and uses it to analyze the issue, providing a fast and effective diagnosis.
Follow the technician’s instructions and perform the following steps when requested.
HOLD the mouthpiece of your phone over the POWER button, when instructed to do so by the call center, no more than one inch from (but not touching) the machine. NOTE: Do not press any other buttons or turn the cycle selector knob.
PUSH and hold the TEMP button while continuing to hold your phone to the POWER button.
LISTEN for three beeps. After you hear the three beeps, release the TEMP button. Keep the phone in place until the tone transmission has finished. This takes about 17 seconds, and the display will count down the time. Once the countdown is over and the tones have stopped, resume your conversation with the technician, who will then be able to assist you in using the information transmitted for analysis.

BEFORE CALLING FOR SERVICE
Problem Possible Cause Solutions *CHECK VENT is blinking
Exhaust system is too long or has too many turns/restrictions.
Install a shorter or straighter duct run. See the Installation Instructions for details.
Partial blockage of the ductwork due to lint buildup or other foreign object.
Ductwork should be checked/cleaned immediately. Dryer can be used in this condition, but drying times will be longer and energy consumption will increase.
* This warning light does not indicate a dryer failure and is not covered by the dryer warranty. Contact a duct cleaning service to set up an appointment to have your exhaust system cleaned and inspected.
Dryer will not turn on Power cord is not properly plugged in.
Make sure that the plug is securely plugged into a grounded outlet matching the dryer’s rating plate.
Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a circuit overload, have it corrected by a qualified electrician. Dryer does not heat House fuse is blown, circuit breaker has tripped, or power outage has occurred.
House fuse is blown, circuit breaker has tripped, or power outage has occurred.
Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a circuit overload, have it corrected by a qualified electrician.
Confirm that the house gas shutoff and the dryer gas shutoff valves are both fully open. Even if gas is not supplied to the dryer, it will run and no error codes will display. Verify that other gas appliances in the home are working normally. Greasy or dirty spots on clothes
Gas supply or service is turned off (gas models only).
Clean and dirty clothes are being dried together.
Only use your dryer to dry clean items. Soil from dirty clothes can transfer to the clean clothes in the same or later loads.
Stains on dried clothes could be stains that weren’t removed during the washing process. Make sure that clothes are being completely cleaned or rinsed according to the instructions for your washer and detergent. Some difficult soils may require pre-treating prior to washing. Excess static in clothes after drying
Clothes were not properly cleaned or rinsed before being placed in the dryer.
Use a fabric softener or the STATIC SHIELD option, if equipped, to reduce static electricity. Be sure to follow the fabric softener manufacturer’s instructions. Overdrying a load of laundry can cause a buildup of static electricity. Adjust settings and use a shorter drying time, or use AUTO DRY cycles. Select a LESS DRY setting on AUTO DRY cycles, if necessary. These fabrics are naturally more prone to static buildup. Try using fabric softener, or use LESS DRY and/or shorter TIMED DRY time settings. Drying time is not consistent
Fabric softener is not used or used incorrectly.
Clothes dried too long (over dried).
Drying synthetics, permanent press, or synthetic blends.
Heat settings, load size, or dampness of clothing is not consistent.
The drying time for a load will vary depending on the type of heat used (electric, natural gas, or LP gas), the size of the load, the type of fabrics, the wetness of the clothes, and the condition of the exhaust duct and lint filter. Even an unbalanced load in the washer can cause poor spinning, resulting in wetter clothes which will take longer to dry.

BEFORE CALLING FOR SERVICE (continued)
Problem Possible Cause Solutions Clothes take too long to dry
Exhaust ducts are blocked, dirty, or duct run is too long.
Confirm that the exhaust duct is properly configured and free of debris, lint, and obstructions. Make sure that outside wall dampers can open properly and are not blocked, jammed, or damaged. Separate heavy items from lightweight items. Larger and heavier items take longer to dry. Light items in a load with heavy items can fool the sensor because the light items dry faster. Heavy fabrics take longer to dry because they tend to retain more moisture. To help reduce and maintain more consistent drying times for large and heavy fabrics, separate these items into smaller loads of a consistent size.
Load is not properly sorted.
Large load of heavy fabrics.
Dryer controls are not set properly.
Use the appropriate control settings for the type of load you are drying. Some loads may require an adjustment of the DRY LEVEL setting for proper drying. Remove the lint from the filter before every load. With the lint removed, hold the filter up to a light to see if it is dirty or clogged. If it looks dirty, follow the cleaning instructions Care and Cleaning section. With some loads that produce high amounts of lint, such as new bath towels, it may be necessary to pause the cycle and clean the filter during the cycle. Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a circuit overload, have it corrected by a qualified electrician.
Lint filter needs to be cleaned.
House fuse is blown, circuit breaker has tripped, or power outage has occurred.
Dryer is overloaded.
Divide extra large loads into smaller loads for better drying performance and efficiency.
If you are drying a very small load, add a few extra items to ensure proper tumbling action. If the load is very small and you are using AUTO DRY cycles, the electronic control cannot properly sense the dryness of the load and may shut off too soon. Use TIMED DRY or add some extra wet clothes to the load. Clothes are wrinkled Clothes dried too long (overdried).
Dryer is underloaded.
Overdrying a load of laundry can lead to wrinkled clothes. Try a shorter drying time or LESS DRY setting and remove items while they still retain a slight amount of moisture. Use the WRINKLE GUARD option. This feature will tumble the clothes briefly every few minutes for up to 150 minutes to help prevent wrinkling. Clothes are shrinking Garment care instructions are not being followed.
Clothes left in dryer too long after cycle ends.
To avoid shrinking your clothes, always consult and follow fabric care instructions. Some fabrics will naturally shrink when washed. Other fabrics can be washed but will shrink when dried in a dryer. Use a low or no heat setting and/or the RACK DRY cycle.

BEFORE CALLING FOR SERVICE (continued)
Problem Possible Cause Solutions Display shows error code: tE1 or tE2
Temperature sensor failure. Turn off the dryer and call for service.
Lint on clothes Lint filter not cleaned properly.
Remove the lint from the filter before every load. With the lint removed, hold the filter up to a light to see if it is dirty or clogged. If it looks dirty, follow the cleaning instructions in the Care and Cleaning Section. With some loads that produce high amounts of lint, it may be necessary to clean the filter during the cycle.
Laundry not sorted properly.
Some fabrics are lint producers (i.e., a fuzzy white cotton towel) and should be dried separately from clothes that are lint trappers (i.e., a pair of black linen pants).
Excess static in clothes.
Use a fabric softener to reduce static electricity. Be sure to follow the manufacturer’s instructions. Overdrying a load of laundry can cause a buildup of static electricity. Adjust settings and use a shorter drying time, or use AUTO DRY cycles.
Dryer is overloaded.
Divide extra large loads into smaller loads for drying.
Check pockets thoroughly before washing and drying clothes. Steam Features Not Working
Tissue, paper, etc., left in pockets.
Steam is not generated and no error code is displayed.
Check for condensation on the inside of the door during steam portion of the cycle. Steam is not directly visible. This is normal. Check steam feeder drawer:
(1) Make sure steam feeder is filled with water to the MAX line. (2) Make sure steam feeder is seated properly and drawer is fully closed. (3) Turn the dryer off, then turn back on and restart the steam cycle. DO NOT USE DISTILLED WATER - The water level sensors in the steam generator will not work. Steam feeder pump not working - call for service.
Garments are still wrinkled at the end of the STEAM REFRESH cycle.
Load only one to five garments (or a single bulky item). Do not mix fabric types. STEAM REFRESH is most effective on 70/30 cotton/polyblends. Do not use on 100% cotton items.
Water drips down the door during steam cycles.
Steam is invisible. However, under some conditions, the condensed fog may be seen, or condensation will form on the inside of the door glass and may be seen dripping down the glass.
Drum does not turn during steam cycles.
The drum is turned off so that the steam vapor remains in the drum. The drum will turn for only a few seconds, once a minute.
Cannot see steam vapor at the beginning of the cycle.
Steam is released at different stages of the cycle for each option. Steam cannot be seen, but condensation may form on the inside of the door when steam is being generated.
Odors are not completely removed at the end of the STEAM REFRESH cycle.
Some odors are difficult to remove. Fabrics containing certain difficult odors or very strong odors may not refresh well and should be washed or dry cleaned instead.

Kenmore Elite Limited Warranty When installed, operated and maintained according to all instructions supplied with the product, if this appliance fails due to a defect in material and workmanship within one year from the date of purchase, call 1-800-4-MY-HOME® to arrange for free repair. If this appliance is ever used for other than private family purposes, this warranty applies for only 90 days from the date of purchase. This warranty covers only defects in material and workmanship. Sears will NOT pay for:
1. Expendable items that can wear out from normal use, including but not limited to filters, belts, light bulbs, and bags. 2. A service technician to instruct the user in correct product installation, operation or maintenance. 3. A service technician to clean or maintain this product. 4. Damage to or failure of this product if it is not installed, operated or maintained according to all the instructions supplied with the product. 5. Damage to or failure of this product resulting from accident, abuse, misuse or use for other than its intended purpose. 6. Damage to or failure of this product caused by the use of detergents, cleansers, chemicals or utensils other than those recommended in all instructions supplied with the product. 7. Damage to or failure of parts or systems resulting from unauthorized modifications made to this product.
Disclaimer of implied warranties; limitation of remedies
Customer’s sole and exclusive remedy under this limited warranty shall be product repair as provided herein. Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. Sears shall not be liable for incidental or consequential damages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, or limitation on the duration of implied warranties of merchantability or fitness, so these exclusions or limitations may not apply to you.
This warranty applies only while this appliance is used in the United States or Canada.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Sears Brands Management Corporation, Hoffman Estates, IL 60179
Sears Canada Inc., Toronto, Ontario, Canada M5B 2C3

Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| *CHECK VENT is blinking * This wa warranty exhaust s | Exhaust system is too long or has too many turns/restrictions. Partial blockage of the ductwork due to lint buildup or other foreign object. | Install a shorter or straighter duct run. See the Installation Instructions for details. Ductwork should be checked/cleaned immediately. Dryer can be used in this condition, but drying times will be longer and energy consumption will increase. ure and is not covered by the dryer p an appointment to have your | p.31 |
| *CHECK VENT is blinking * This wa warranty exhaust s | rning light does not indicate a dryer fail . Contact a duct cleaning service to set u ystem cleaned and inspected. | ure and is not covered by the dryer p an appointment to have your | p.31 |
| Dryer will not turn on | Power cord is not properly plugged in. House fuse is blown, circuit breaker has tripped, or power outage has occurred. | Make sure that the plug is securely plugged into a grounded outlet matching the dryer’s rating plate. Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a circuit overload, have it corrected by a qualifei d electrician. | p.31 |
| Dryer does not heat | House fuse is blown, circuit breaker has tripped, or power outage has occurred. Gas supply or service is turned off (gas models only). | Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a circuit overload, have it corrected by a qualifei d electrician. NOTE: Due to the design of electric dryers, it is possible for a circuit problem to allow an electric dryer to run without heat. Confri m that the house gas shutof f and the dryer gas shutof f valves are both fully open. Even if gas is not supplied to the dryer, it will run and no error codes will display. Verify that other gas appliances in the home are working normally. | p.31 |
| Greasy or dirty spots on clothes | Clean and dirty clothes are being dried together. Clothes were not properly cleaned or rinsed before being placed in the dryer. | Only use your dryer to dry clean items. Soil from dirty clothes can transfer to the clean clothes in the same or later loads. Stains on dried clothes could be stains that weren’t removed during the washing process. Make sure that clothes are being completely cleaned or rinsed according to the instructions for your washer and detergent. Some difficult soils may require pre-treating prior to washing. | p.31 |
| Excess static in clothes after drying | Fabric softener is not used or used incorrectly. Clothes dried too long (over dried). Drying synthetics, permanent press, or synthetic blends. | Use a fabric softener or the STATIC SHIELD option, if equipped, to reduce static electricity. Be sure to follow the fabric softener manufacturer’s instructions. Overdrying a load of laundry can cause a buildup of static electricity. Adjust settings and use a shorter drying time, or use AUTO DRY cycles. Select a LESS DRY setting on AUTO DRY cycles, if necessary. These fabrics are naturally more prone to static buildup. Try using fabric softener, or use LESS DRY and/or shorter TIMED DRY time settings. | p.31 |
| Drying time is not consistent | Heat settings, load size, or dampness of clothing is not consistent. | The drying time for a load will vary depending on the type of heat used (electric, natural gas, or LP gas), the size of the load, the type of fabrics, the wetness of the clothes, and the condition of the exhaust duct and lint filter. Even an unbalanced load in the washer can cause poor spinning, resulting in wetter clothes which will take longer to dry. | p.31 |
| Clothes take too long to dry | Exhaust ducts are blocked, dirty, or duct run is too long. Load is not properly sorted. Large load of heavy fabrics. Dryer controls are not set properly. Lint fliter needs to be cleaned. House fuse is blown, circuit breaker has tripped, or power outage has occurred. Dryer is overloaded. Dryer is underloaded. | Confri m that the exhaust duct is properly confgi ured and free of debris, lint, and obstructions. Make sure that outside wall dampers can open properly and are not blocked, jammed, or damaged. Separate heavy items from lightweight items. Larger and heavier items take longer to dry. Light items in a load with heavy items can fool the sensor because the light items dry faster. Heavy fabrics take longer to dry because they tend to retain more moisture. To help reduce and maintain more consistent drying times for large and heavy fabrics, separate these items into smaller loads of a consistent size. Use the appropriate control settings for the type of load you are drying. Some loads may require an adjustment of the DRY LEVEL setting for proper drying. Remove the lint from the fliter before every load. With the lint removed, hold the fliter up to a light to see if it is dirty or clogged. If it looks dirty, follow the cleaning instructions Care and Cleaning section. With some loads that produce high amounts of lint, such as new bath towels, it may be necessary to pause the cycle and clean the fliter during the cycle. Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a circuit overload, have it corrected by a qualifei d electrician. NOTE: Due to the design of electric dryers, it is possible for a circuit problem to allow an electric dryer to run without heat. Divide extra large loads into smaller loads for better drying performance and efcfi iency. If you are drying a very small load, add a few extra items to ensure proper tumbling action. If the load is very small and you are using AUTO DRY cycles, the electronic control cannot properly sense the dryness of the load and may shut of f too soon. Use TIMED DRY or add some extra wet clothes to the load. | p.32 |
| Clothes are wrinkled | Clothes dried too long (overdried). Clothes left in dryer too long after cycle ends. | Overdrying a load of laundry can lead to wrinkled clothes. Try a shorter drying time or LESS DRY setting and remove items while they still retain a slight amount of moisture. Use the WRINKLE GUARD option. This feature will tumble the clothes briefyl every few minutes for up to 150 minutes to help prevent wrinkling. | p.32 |
| Clothes are shrinking | Garment care instructions are not being followed. | To avoid shrinking your clothes, always consult and follow fabric care instructions. Some fabrics will naturally shrink when washed. Other fabrics can be washed but will shrink when dried in a dryer. Use a low or no heat setting and/or the RACK DRY cycle. | p.32 |
| Display shows error code: tE1 or tE2 | Temperature sensor failure. | Turn of f the dryer and call for service. | p.33 |
| Lint on clothes | Lint fliter not cleaned properly. Laundry not sorted properly. Excess static in clothes. Dryer is overloaded. Tissue, paper, etc., left in pockets. | Remove the lint from the fliter before every load. With the lint removed, hold the fliter up to a light to see if it is dirty or clogged. If it looks dirty, follow the cleaning instructions in the Care and Cleaning Section. With some loads that produce high amounts of lint, it may be necessary to clean the fliter during the cycle. Some fabrics are lint producers (i.e., a fuzzy white cotton towel) and should be dried separately from clothes that are lint trappers (i.e., a pair of black linen pants). Use a fabric softener to reduce static electricity. Be sure to follow the manufacturer’s instructions. Overdrying a load of laundry can cause a buildup of static electricity. Adjust settings and use a shorter drying time, or use AUTO DRY cycles. Divide extra large loads into smaller loads for drying. Check pockets thoroughly before washing and drying clothes. | p.33 |
| Steam Features Not Working | Steam is not generated and no error code is displayed. Garments are still wrinkled at the end of the STEAM REFRESH cycle. Water drips down the door during steam cycles. Drum does not turn during steam cycles. Cannot see steam vapor at the beginning of the cycle. Odors are not completely removed at the end of the STEAM REFRESH cycle. | Check for condensation on the inside of the door during steam portion of the cycle. Steam is not directly visible. This is normal. Check steam feeder drawer: (1) Make sure steam feeder is filled with water to the MAX line. (2) Make sure steam feeder is seated properly and drawer is fully closed. (3) Turn the dryer off, then turn back on and restart the steam cycle. DO NOT USE DISTILLED WATER - The water level sensors in the steam generator will not work. Steam feeder pump not working - call for service. Load only one to fvi e garments (or a single bulky item). Do not mix fabric types. STEAM REFRESH is most efef ctive on 70/30 cotton/polyblends. Do not use on 100% cotton items. Steam is invisible. However, under some conditions, the condensed fog may be seen, or condensation will form on the inside of the door glass and may be seen dripping down the glass. The drum is turned of fso that the steam vapor remains in the drum. The drum will turn for only a few seconds, once a minute. Steam is released at difef rent stages of the cycle for each option. Steam cannot be seen, but condensation may form on the inside of the door when steam is being generated. Some odors are difcfi ult to remove. Fabrics containing certain difcfi ult odors or very strong odors may not refresh well and should be washed or dry cleaned instead. | p.33 |