Instruction/ maintenance manual of the product 305 Kenmore
Go to page of 36
Owner's Manual 305 and 505 Models Direct Vent Tankless Water Heaters FOR OUTDOOR APPLICATIONS ONLY MODEL NO. 154.330040 Natural Gas 305 Series 154.
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard.
Safety Behavior and Practices Keep the area around the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Safe Installation, Use and Service ........................... 2 Safety Precautions .................................................... 2 Safety Behaviors and Practices ............................ 3 Safety Features ..................................
12 Year Limited Warranty on Heat Exchanger For 12 years from the date of purchase, if this water heater is installed and operated in a single family home in accordance with the owner's manual instructions and all local codes, Sears will supply a free heat exchanger f_r one that develops a leak.
Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME ®. They will arrange for prompt, quality installation by Sears authorized contractors.
MODEL Minimum gas consumption btu/h Maximum gas consumption btu/h 305 Models 154.330040 & 154.330050 505 Models 154.330080 & 154.330090 15,000 180,000 Natural Gas 199,000 Natural Gas 180,000 Propane Gas 199,000 Propane Gas Hot water capacity (Min - Max) * 0.
+,,el ++D K DIM DESCRIPTION 305 Series 505 Series in. (mm) in. (mm) A Width 14 (355.6) 14 (355.6) B Depth * 9.8 (249.5) 9.8 (249.5) C Height- Unit 22.9 (582) 22.9 (582) D Height- with brackets 25.4 (646.4) 25.4 (646.4) E Hot Water Outlet - from wall * 3.
Pressure Drop Curve 45 40 35 3O o_ 25 v 09 09 o 20 d -' 15 09 09 n 10 305 505 i-- / 4 6 8 10 12 100 9O 8O 70 m d) 1.. 6O 50 o _J 4O 30 2O a_ 10 Water Flow (gpm) Outlet Flow Data 9.
Only properly trained and qualified installers should install this appliance. The warranty may be voided due to improper installation or installation by a non-qualified installer. It is highly recommended that all installers attend a product knowledge class.
Table 1: to Combustibles to Non-Combustibles Back of 0 (zero) 0 (zero) Heater Front of 24 inches 24 inches Heater (610 mm) (610 mm) Sides of 6 inches 1/8 inches Heater (152 mm) (3.2 mm) Floor/ 12 inches 2 inches Ground (305 mm) (51 mm) The clearance for servicing is 24 inches in front of the water heater.
Pipe Sizing Procedure - Example The gas supply must be capable of handling the entire gas load at the location. Gas line sizing is based on gas type, the pressure drop in the system, the gas pressure supplied, and gas line type. Refer to the National Fuel Gas Code, NFPA 54, for proper gas line sizing.
General Instructions A manual water control valve must be placed in the water inlet connection to the water heater before it is connected to the water line. Unions may be used on both the hot and cold water lines for future servicing and disconnection of the unit.
Figure 4: Freeze Protection Piping - Drawing o o Vacuum Breaker Water Heater NOTE: Heat trace (heat tape) ALL water pipe and fittings located outside home (attic, crawl space) or building structure. (ALL water pipe and fittings shown above the dashed line in the drawing.
Figure 5: Recommended Piping for Basic Installation I_o n o_1 o o Water Heater O O Equipment List QTY Water Heaters 1 Plumbing Installation 1 Kit (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.
Figure 6: Recommended Piping for Circulation Systems NOTE: Applications, using this piping arrangement maintains full warranty. For this application: Pump should be controlled by an Aqua- stat, Timer or Combination Aquastat and Timer. Pump to be sized to maintain circulation loop temperature.
Figure 7: Optional Piping for Circulation Systems NOTE: Applications, using this piping arrangement reduces the warranty to the following: 3 years on heat exchanger 3 year on parts Full warranty will be maintained if an on-demand recirculation system in incorporated.
CLOSED (_ AIR SUPPLY INLET E_] VENT TERMINAL AREA WHERE TERMINAL IS NOT PERMITTTED d) © Ref A B C D US Installations 12 inches (30 cm) 12 inches (30 cm) E * F Clearance * G Clearance * H Clearance * .
Additional Clearance - Vent Terminal Local codes supersede these clearances, • Avoid termination locations near a dryer vent, • Avoid termination locations near commercial cooking exhaust.
Set dip switches 2 and 3 to the values shown in table below for your altitude. The default setting for the appliance is 0-2000 ft (0-610 m) with switches No. 2 and No. 3 in the OFF position. DO NOT adjust the other dip switches unless specifically instructed to do so.
Location Mounting the Controller Outdoor models are supplied with one remote control unit. Additional controllers can also be installed. • The controller should be out of reach of small children. • Avoid locations where the controller may become hot (near the oven or radiant heater).
This appliance is one of the most advanced water heaters available. It provides a continuous supply of hot water at a preset temperature. This appliance is direct vent where air is brought in from the outside and combustion gases are exhausted to the outside.
IF!II mT± d -'tl Water temperature over 125°F (52°C) can cause servere burns instantly resulting in severe injury or death. Children, the elderly, and the physically or mentally disabled are at highest risk for scald injury. Feel water before bathing or showering.
Temperature Options without a Temperature Controller Do not adjust the other dip switches unless specifically instructed to do so. The default temperature setting for this appliance installed without a remote controller is 120° F (49 ° C). If desired the temperature setting can be changed to 140 ° F (60 ° C) by adjustment of a dip switch.
A. a. FOR YOUR SAFETY READ BEFORE OPERATING I If you do not follow these instructions exactly, a fire or explosion I may result causing property damage, personal injury or loss of life. I This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner.
Turn off the electrical power supply, the manual gas valve and the manual water control valve whenever servicing the unit. Repairs and maintenance should be performed by a qualified service technician. The appliance should be inspected annually by a qualified service technician.
This appliance has the ability to check its own operation continuously. If a fault occurs, an error code will flash on the Display of the temperature controller. This assists with diagnosing the fault and may enable you to overcome a problem without a service call.
Code Fault 14 Thermal Fuse 16 32 33 34 Over Temperature Warning Outgoing Water Temperature Sensor Fault Heat Exchanger Outgoing Temperature Sensor Fault Combustion Air Temperature Sensor Fault Remedy Check gas type of unit and ensure it matches gas type being used.
Troubleshooting for Common Issue I don't have any hot water when I open the tap. Make sure there is gas, water, and electricity to the water heater (power is turned on and the gas is turned on). When I was using the hot water, the water got cold.
Flushing the Heat Exchanger (Error Code: LC or 00) An "LC" or "00" error code indicates the unit is beginning to lime up and must be flushed. Failure to flush the appliance will cause damage to the heat exchanger. Damage caused by lime build-up is not covered by the unit's warranty.
3A(FUSE) ARRESTER GND HOT FROST SENSING SWITCH VARISTOR N NEUTRAL ANTI-FROST HEATER IGNITION J ® i SW,TC_,s__F_ ...... i_ e , _-, J WATER FLOW Q SENSOR (_ ATER FLOW SENSOR CiRCUiT WATER FLOW Q CON_L .
Contact Sears Service Center at: 1-800-4-MY-HOME® (1-800-469-4663). For the convenience of the Qualified Service Technician a Technical Data Sheet has been placed inside the front cover of the water heater.
305 &505 Outdoor Manual 33.
34 305 & 505 Outdoor Manual.
305 &505 Outdoor Manual 35.
iiiiiiiiiiiiiiiiiiii ¸¸¸ iiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiiiii Your Home _/////////////////////_ For expert troubleshooting and home solutions advice: ÷anag÷ ÷e iiiiiiii.
An important point after buying a device Kenmore 305 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Kenmore 305 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Kenmore 305 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Kenmore 305 you will learn all the available features of the product, as well as information on its operation. The information that you get Kenmore 305 will certainly help you make a decision on the purchase.
If you already are a holder of Kenmore 305, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Kenmore 305.
However, one of the most important roles played by the user manual is to help in solving problems with Kenmore 305. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Kenmore 305 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center