TK-C676
INSTRUCTIONS

a damp cloth for cleaning. 5. Do not use attachments not recommended by the appliance manufacturer as they may cause hazards. 6. Do not use this appliance near water – for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet
basement, or near a swimming pool, etc. 7. Do not place this appliance on an unstable cart, stand, or table. The appliance may fall,
(symbol provided by RETAC)
causing serious injury to a child or adult, and serious damage to the appliance. Use only with a cart or stand recommended by the manufacturer, or sold with the appliance. Wall or shelf mounting should follow the manufacturer’s instructions, and should use a mounting kit approved by the manufacturer. An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn. 8. Slots and openings in the cabinet and the back or bottom are provided for ventilation, and to
insure reliable operation of the appliance and to protect it from overheating, these openings must not be blocked or covered. The openings should never be blocked by placing the appliance on a bed, sofa, rug, or other similar surface. This appliance should never be placed near or over a radiator or heat register. This appliance should not be placed in a built-in installation such as a bookcase unless proper ventilation is provided. 9. This appliance should be operated only from the type of power source indicated on the marking label. If you are not
sure of the type of power supplied to your home, consult your dealer or local power company. For appliance designed to operate from battery power, refer to the operating instructions. 10. This appliance system is equipped with a 3-wire grounding type plug (a plug having a third (grounding) pin). This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding plug. 11. For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it form the wall outlet and disconnect the antenna or cable system. This will prevent damage to the product due to lightning and power-line surges. 12. Do not allow anything to rest on the power cord. Do not locate this appliance where the cord will be abused by persons walking on it. 13. Follow all warnings and instructions marked on the appliance. 14. Do not overload wall outlets and extension cords as this can result in fire or electric shock. 15. Never push objects of any kind into this appliance through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the appliance. 16. Do not attempt to service this appliance yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel. 17. Unplug this appliance from the wall outlet and refer servicing to qualified service personnel under the following condi- tions: a. When the power cord or plug is damaged or frayed. b. If liquid has been spilled into the appliance. c. If the appliance has been exposed to rain or water. d. If the appliance does not operate normally by following the operating instructions. Adjust only those controls that
are covered by the operating instructions as improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the appliance to normal operation. e. If the appliance has been dropped or the cabinet has been damaged. f. When the appliance exhibits a distinct change in performance – this indicates a need for service. 18. When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer that have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards. 19. Upon completion of any service or repairs to this appliance, ask the service technician to perform routine safety checks to determine that the appliance is in safe operating condition.


Features
Even objects that have a large difference in brightness can be monitored clearly. Day/night surveillance
When the light is low, the camera pictures can be switched automatically to black and white pictures. The camera is also compatible with IR illumination (wavelength 850 nm to 880 nm). Private masking facility
When the camera target area contains an area that is required to be hidden the camera can be set accordingly in order to mask it. Simplified waterproof design
The simplified waterproof design (IEC529) of the camera allows it to be installed in many locations, including under eaves, provided that it is not subjected to direct water splash. (However, note that the camera cannot be used outdoors.) Optical + electronic zooming
The 27X optical zoom lens and 10X electronic zoom circuitry allows the camera to be used even in surveillance situations in which the object is very small. High-sensitivity CCD and bright zoom lens
The CCD features an improved sensitivity of nearly 70% over the previous model and the zoom lens has a large aperture ratio of f1.4 (at WIDE end). These features provide the camera with a high sensitivity of 0.5 lx in the color mode (25% output, AGC 20 dB, WIDE end, electronic sense up x2). High-speed pan/tilt table
The high-speed rotating table with a horizontal panning speed of 300°/sec. and a vertical tilting speed of 180°/sec. makes it possible to recall a preset position quickly.
TK-C676
INSTRUCTIONS
LWT0003-001A-H
Screw (M3 × 12 mm) For cable plate
Cable plate 4P Alarm cable 6P Alarm cable Screws (M 4 x 12 mm) For the ceiling flush mount bracket
Safety Precautions
WARNING • Install the unit on a strong and stable surface. This unit has been designed to revolve at high speed. Due to its weight (about 2.4 kg) and the vibrations it may be subjected to, the camera must be mounted to a sturdy and stable material. If the ceiling material lacks strength, for example it is made of a decorative laminated material or plasterboard, then the mount should be reinforced using materials such as veneered plywood. If such reinforce- ment is inadequate images may fluctuate due to vibration or, in the worst case, the camera may fall and cause a serious accident should there be anyone below it.

When zooming is stopped near the TELE end during manual operation or by selecting a preset position, focusing may deviate slightly. In addition, the manual zooming operation may not al- ways be smooth. These phenomena are due to the characteristics of the built-in lens and are not malfunctions. Preset positions

Controls, Connectors and Indicators
I Camera body
Ceiling Mount
8 7 9 6

Pin 1 of CONTROL terminal (CN22)
Pin 1 of ALARM I/O terminal (CN23)
Pin 1 of alarm input terminal (CN26)
(Connector side)
(Terminal Pin Layout)
1 [VIDEO OUT] Coaxial Cable Connectors Output connector of a composite video signal (1 V(p-p)) with an output impedance of 75 Ω, to be connected to a switcher, etc. 2 [AC ` 24V INPUT] Connector Connect to a 24 V AC power supply.
7 [ALARM I/O] Input/Output Terminals (CN23) Terminals for Alarm input 1 and Alarm output 1. P. 15
3 Cover Position Alignment Mark When attaching the cover, use this mark to align its final position correctly. 4 Locking Screw Tighten this screw to fasten the camera clamping bracket *. 5 Safety Wire Hole To prepare for possible dropping of the camera, pass the wire from the ceiling slab or channel through this hole. 6 Alarm Input Terminals (CN26) Input terminals for Alarm 2, Alarm 3 and Alarm 4. Connect the provided cables to these terminals. P. 15
8 [CONTROL] Terminals (CN22) Connect to a RM-P2580 remote control unit.





⁄
# @ !
0 Cover For protection against water drips. Slit the rubber cap on this cover and pass the cable through the slits. P. 14
Connect to !, the Female Camera Connector on the Ceil- ing Mount. & Drop Prevention Wire
Attach this wire to the Drop Prevention Hook @ on the Ceiling Mount. * Camera Clamping Bracket In order to clamp the camera onto the Ceiling Mount, in- sert and tighten the Locking Screw 4 into this bracket. ( Lens
Connect to ^, the Male Connector on the camera. @ Drop Prevention Hook
Attach the Drop Prevention Wire & to this hook to prevent the camera from falling. # Clamping Holes (x 4)
Attach the camera to a ceiling or to a Ceiling Flush Mount Bracket (optionally available) using these holes. $ [MACHINE ID] Switch
The dome cover is fragile. Take care when handling it. ⁄ Camera Body Cover
When an RS-485 communication system is used, for ex- ample when using the camera in a system controlled by an RM-P2580, set the camera IDs individually for each camera. P. 13
Do not remove the camera body cover while the camera is installed on a ceiling. Doing so will cause the dome cover to fall down.

A Multi-Drop Communication System
A system that employs the RM-P2580 as the controller
The following figure shows a system that can accommodate up to eight cameras. (64 positions can be preset per camera.)
AC 24 V power supply
AC 24 V power supply
AC 24 V power supply
VIDEO OUTPUT VIDEO OUTPUT
ON
Cable connections P. 14
MONITOR OUTPUT 1
(Terminal side of Ceiling Mount)
Switch settings P. 12
To the TO CAMERA connector of the RM-P2580 and to the next camera Coaxial cable To the CAMERA INPUT connector of the RM-P2580
To AC 24V power supply
F
F
Connection of the control signal cable (A twisted pair cable is recommended.)
Switch 1 : Switch 2 : Switch 4 : ON Switch 5 : OFF Switch 7 : Invalid (Set to OFF) Switch 8 :
Invalid (Set to OFF.)
Camera 1 CONTROL terminals
Set it to the same number as the VIDEO INPUT terminal of the RM- P2580. (Example) Camera 1: Set the figure of 10 to “0” and figure of 1 to “1”. Set to ON only for the camera connected at the end of the control signal cable. Set to OFF for all other cameras.
L PROCESS> I I N T I A
: - - I - - PAN : - - I - - T I LT
Duplex display ID No. display

Be sure to terminate the control signal cable at both ends. The cables (length of stub) connecting pieces of non-terminated equipment (cameras or controllers) must be as short as possible. If the length of stub is too long, control precision may suffer.
VIDEO SWITCHER, etc.
Length of stub CAM1 CAM2 CAM32 Terminate it with 110 Ω.
VIDEO SWITCHER, etc.

Point-to-Point Communication System
The following illustration shows a system in which a remote control unit (or a similar piece of equipment) controls a single camera.

Switch settings P. 12
(Setting switches are on the side of the Ceiling Mount)


To the AC 24V power supply
Switch 1 : OFF Switch 2 : OFF Switch 4 : OFF Switch 5 : Configure in accordance with the requirements of the controller communication system.
If this camera or the cables connected to this camera are used in places subject to strong electromagnetic waves or other forms of magnetism, for example near a radio or TV transmitter, a power transformer or an electric motor, the picture may suffer from noise and colors may be affected. An optionally available controller is required to use a TK-C676 camera. Please contact your local dealer or installer for more information about these controllers.
To controller · To monitor

Use twisted-pair cables for the connections.
Camera Controller RX+
TX+
TX+
RX–
TX–
RX–
TX–
TX+
RX+
Two wires must be connected.
RX–
Four wires must be connected.
Camera RM-P2580 RX+ C
C TX+
RX– D
D TX–
TX+ A
A RX+
TX– B
B RX–

Switch Settings
Set the switches on the Ceiling Mount before installing the camera. Settings vary according to configuration of the system used.
Switch 1 Switch 2 Switch 3 DISP Switch 4 PROTOCOL(1) Switch 5 PROTOCOL(2) Switch 6 SYNC Switch 7
Reserved This switch must be set “OFF”
Switch 8 RX TERM
F
F
SYNC Switch 6 INT OFF LL ON (Initial set: OFF)
Switch 3 MANUAL Displayed Not displayed
ON
When the system in which this camera is used is a multi- drop system (RS-485 system), set only the camera located at the extreme end of the control signal cables to “Termi- nated” and set the other cameras to “Open”.
When set to Multi drop, be sure to set the Machine ID of each camera.

Figure of 10
In a system using an RM-P2580, multiple cameras are connected by a single set of control cables. An error in the switch setting of even a single camera will make the entire system inoperable.
<Camera ID check procedure> 1. Set the picture being monitored to that of the camera to be checked. 2. Turn the AC 24V power source of the camera OFF and then ON again. 3. The camera now performs the initialization operation and the following display appears:
(Example) The machine ID of the camera con- nected to VIDEO INPUT 1 should be set to “0” “1” as shown on the right.
Figure of 10 Figure of 1
P R O C E S S I N T I I A L
I - - P N A : - -
I - - T I T L : - -
U P L E X I D - 1 0 P RO T O C L D
“DUPLEX” should be displayed. “ID-□□” is displayed. Ensure that the number □□ is correct.
“0” “1”

Cable Connections
Connect cables to the Ceiling Mount as described below.

Control signal cable To a remote controller such as RM-P2580

To the monitor, etc.
To the AC 24 V power supply
This cable connects the AC 24V power supply to the AC 24V input connector. To prevent connection errors and disconnections, the use of lug plate for connections to the AC 24 V INPUT connector is recommended.
When a 2-conductor VVF (Vinyl-insulated vinyl-sheath ca- ble) is used, the maximum connection length is as shown below. (These are merely the standard reference values.)
Maximum cable length 100 m 260 m 410 m 500 m
Wire diameter (mm) 1.0 or more 1.6 or more 2.0 or more 2.6 or more

Tube Maximum diameter 22 mm
The diameter of the cover hole without the cap is 20.5 mm. When the camera is installed in a place where it may some- times be exposed to water splashes, for example under eaves, enclose cables in a drip-proof pipe. (Be sure to use a water-drip pipe that complies with the IP52. standard. The maximum diameter of the pipe con- nector is 31 mm.) When distributing the cable from the side, use the WB- S573 ceiling direct-mount bracket. In this case, the length of the connector should be 33 mm or less, and the maxi- mum diameter of the tube should be 22 mm or less.
Diameter 90 mm

Alarm signal cables P. 6
Connecting a RG-59 coaxial cable.
Alarm output terminals (CN24) Connect the provided 4P Alarm cable to these terminals.
If a RG-11 coaxial cable is used it cannot be con- nected directly to the terminal board. To use such a cable, connect a RG-59 cable to the camera and then connect the RG-11 cable to the RG-59 cable.
Treat the extremity of the coaxial cable as shown below before connecting it.
Alarm input/output terminals (CN23)
Fold back the mesh wires and secure them with insulation tape in order to prevent them from becoming loose and thus causing a short circuit.
Alarm input terminals (CN26) Connect the provided 6P Alarm cable to these terminals.
17 (12) Insulation tape
The figures inside the brackets ( ) are the dimensions when the coaxial cable is distributed from the side of the cover. (Unit : mm)
COM.
If the cable is extended, the signal attenuation is increased, the resolution drops and the noise increases. Should it be required to extend the cable, use a thicker cable or a ca- ble length compensator.
To lead the coaxial cable through the cap on the side of the cover, change the positioning of the cable plate as shown below.
Rating Maximum applied voltage: 30 V DC or 24 V AC Maximum applied current: 2 A Contact life: 200,000 times of

Control signal cables
RM-P2580 units allow the connection of up to eight cam- eras to a single set of control signal cables. The overall maximum permissible length of these control signal cables is 1200 meters.
Electrical Specifications of Alarm Input Terminals
GND • To prevent penetration of noise in the internal circuitry, apply a non- voltage contact signal to the ALARM input terminal Never apply a voltage.
The connector can be released by loosening the screws on the two sides as shown in the figure.
Strip the coating of each cable by about 4 mm before inserting it. After connecting all of the cables, turn the screws on the side to fasten the connectors.
It is recommended to use a 4-core (a pair) twisted pair cable (0.65) or a twisted pair cable of category 3 or higher which is used for a Ethernet.
Cables with a thickness between 16 AWG and 26 AWG can be used. Connect the control signal cables so that the TX+ and TX- signals form a pair and the RX+ and RX- signals form another pair.

Attaching the Ceiling Mount

Attaching the Camera



Camera
Camera clamping bracket

Rotate the camera clockwise.

* To remove of the camera from the ceiling mount, reverse the steps1 to 5.
Tighten the lock screw.

Setup Procedure
In systems using an RM-P2580 remote control unit, the menus for use during camera setup can be displayed on the remote control unit. (Please refer to the instructions for RM-P2580.)

P O S I T I O N S E T U P . . S E T U P
C A M E R A . . C O N T R O L U N I T . .
– – – M E N U – – –
C A M . F U N C T I O N . .
Indication of presence of submenus
C A M . T I T L E / A L A R M . . C A M . V I D E O A D J U S T . . C A M . A L C / E x D R . . H O M E M O T I O N D E T E C T . . A U T O P A N / P A T R O L / T R A C E . . P O S I . F U N C T I O N S E T . . F A C T O R Y S E T T I N G S . .
P O S . T I T L E L O C . U P - L – – – C A M E R A F U N C T I O N – – –
F L I P D I G I T A L V A R . P / T S P E E D O N E A S Y A F O F F D . Z O O M M A X X 2 P R I V A T E M A S K . .
PAN/TILT lever · cursor · Change mark

The menu screens are arranged in a hierarchical structure as shown below. Refer to the respective reference pages for the details of each menu.
P.20
P O S I T I O N S E T U P . . S E T UP
V . P H A S E 0 – – C A M E R A F U N C T I O N – –
C A M E R A . . C O N T R O L U N I T . .
P O S . T I T L E L O C . U P - L F L I P D I G I T A L V A R . P / T S P E E D O N E A S Y A F O F F D . Z O O M M A X X 2 P R I V A T E M A S K . .
C A M . T I T L E E D I T . . – – – C A M E R A T I T L E / A L A R M – – –
CAMERA FUNCTION screen
A R E A T I T L E O F F A R E A T I T L E E D I T . . A L M . T I T L E S I Z E D O U B L E A L M . T I T L E C O L O U R WH I T E A L A R M T I T L E E D I T . . A L A R M I N P U T . . A L A R M O U T P U T . .
C O L O U R L E V E L N O R M A L – – – C A M E R A V I D E O A D J U S T – – –
E N H A N C E L E V E L N O R M A L P E D E S T A L L E V E L N O R M A L A U T O B L K . C T L . O F F
– – – M E N U – – –
C A M . F U N C T I O N . .
C A M . T I T L E / A L A R M . . C A M . V I D E O A D J U S T . . C A M . A L C / E x D R . . H O M E M O T I O N D E T E C T . . A U T O P A N / P A T R O L / T R A C E . . P O S I . F U N C T I O N S E T . . F A C T O R Y S E T T I N G S . .
A V E R A G E : P E A K 8 : 2 – – – C A M E R A A L C / E x D R – – –
S H U T T E R 1 / 5 0 A G C M O D E 1 0 d B S E N S E U P O F F P R I O R I T Y M O T I O N E x D R M O D E O F F E x D R L E V E L – – – B & W / C O L O U R M O D E . .
MENU screen
M O D E O F F – – – H O M E M O T I O N D E T E C T – – –
L E V E L N O R M A L A R E A E D I T . . A L A R M D I S P L A Y 5 s D E M O N S T R A T I O N . .
P.27
A U T O P A N M O D E R E T U R N – – A U T O P A N / P A T R O L / T R A C E – –
A U T O P A N S P E E D N O R M A L A . P A N S T A R T P O S . S E T . . A . P A N R E T U R N P O S . S E T . . A U T O P A T R O L S E T . . A U T O T R A C E S E T . . R M . A . P A N K E Y A . P A N R M . A . P A T R O L K E Y A . P A T R O L
P O S I T I O N T I T L E . . – – P O S I T I O N F U N C T I O N S E T – –
I R I S M O D E A U T O B L C O F F W . B A L A N C E A T W R - B G A I N – – – M - G G A I N – – –
P.28
C A N C E L – – F A C T O R Y S E T T I N G S – –
C L E A R ( W / O P O S I . T I T L E ) C L E A R ( A L L )

CAMERA FUNCTION Screen
This screen sets up the functions of the camera itself.
Function & Setting
Initial Value
V. PHASE
This adjusts the vertical synchronization to those of other cameras when a selector switch for the synchronizing system on the Ceilling Mount is at LL. (50 Hz power region only.) When it is not set to LL, “---” will appear, disabling change the set value. Setting values: –156 to 0 to 156
POS. TITLE LOC.
Sets the location of the position title and area title in the monitor. UP: At the top of the screen. DOWN: At the bottom of the screen. L: In the left half of the screen. C: In the center of the screen. R: In the right half of the screen Setting values: UP-L, UP-C, UP-R, DOWN-L, DOWN-C, DOWN-R
FLIP
When a tilting operation is started while this item is OFF, the camera will stop at the position where it is pointing straight downwards. When an object moves directly below the camera, the camera makes three movements 1 points the straight down- ward 2 pans 180° 3 points upwards. The FLIP function makes it possible to reduce these operations. Use this function when monitoring an object passing directly below the camera. OFF: Turns the FLIP function off. DIGITAL: Once the camera reaches a tilt of 135 degrees from horizontal after
passing a position facing directly downwards, a picture is inverted both vertically and horizontally. AUTO: When the camera reaches a position facing directly downwards, it pans
by 180° then stops.
Under this function, the panning and tilting speeds are adjusted automatically rela- tive to the zoom ratio of the lens. Setting the zoom lens towards TELE decreases the pan and tilting speeds. Setting the zoom lens towards WIDE end increases the pan and tilting speeds. Use this function when monitoring objects at differing zoom ratios. OFF: Turns this function off. ON: Turns this function on.
EASY AF
When this item is set to ON, the auto focusing (AF) is activated automatically dur- ing manual pan/tilt and zoom operations. This function is convenient when frequent manual operations are expected as it eliminates the need to focus manually after every manual operation. OFF: Turns this function off. ON: Turns this function on.
Auto focusing may sometimes be incapable of bringing certain objects into accurate focus. ( P. 4) In this case, use the manual focusing facility.
When the zoom lens is set toward TELE, optical zooming is activated first and electronic zooming second. This function sets the maximum zoom ratio of the electronic zooming. Setting values : x1, x2, x4, x6, x8, x10.
PRIVATE MASK..
This function grays out sections that are not to be displayed in the monitored pic- ture area. The grayed out section moves accordingly when the camera is panned, tilted or when the zoom is adjusted. P.29, “PRIVATE MASK Setup”

This screen sets items related to titles and alarms.
Function & Setting
Initial Value
CAM. TITLE EDIT ..
This sets the title which is displayed permanently at the bottom left of the picture. This title can be up to 16 characters in length. P. 30, “CAMERA TITLE Setup”
The 360° panning range can be divided into 16 areas and a title, of up to 16- character in length, can be set for each area. As the camera is panned manually these area titles are displayed. This function determines whether area titles are displayed or not. ON: Display area titles. OFF: Do not display area titles.
AREA TITLE EDIT ..
ALM. TITLE SIZE
Sets the size of the characters in the alarm title. (Displayed when an alarm is acti- vated.) NORMAL: Same size as the characters used in the menu screen. DOUBLE: Double the size, both horizontally and vertically, of the characters used
in the menu screen.
Sets the color of the alarm titles. Setting values: WHITE, YELLOW, CYAN, GREEN
ALARM TITLE EDIT ..
ALARM INPUT ..
Sets the configuration of the alarm input terminals on the Ceiling Mount. The picture can be turned black-and-white mode when an alarm signal is input. P. 25, Item “B&W”
Sets the camera position for alarm 1. When an alarm signal is input to the Alarm 1 input terminal, the camera moves to this set position. HOME means the home position and POS1 means position 1. Setting values: OFF, HOME, POS1 to POS99.
ALARM IN2
Sets the camera position for alarm 2. When an alarm signal is input to the Alarm 2 input terminal, the camera moves to this set position. HOME means the home position and POS1 means position 1. Setting values: OFF, HOME, POS1 to POS99.
ALARM IN3
Sets the camera position for alarm 3. When an alarm signal is input to the Alarm 3 input terminal, the camera moves to this set position. HOME means the home position and POS1 means position 1. Setting values: OFF, HOME, POS1 to POS99.
ALARM IN4
Sets the camera position for alarm 4. When an alarm signal is input to the Alarm 4 input terminal, the camera moves to this set position. HOME means the home position and POS1 means position 1. Setting values: OFF, HOME, POS1 to POS99.

CAMERA TITLE/ALARM Screen (Continued)
Function & Setting
Initial Value
ALARM INPUT ..
POLARITY
Sets the polarity of the alarm signal inputs. MAKE: Alarm signals are transmitted when point of contact is made. BREAK: Alarm signals are transmitted when contact is broken.
When an item for the B&W is set to the ALARM 1 to 4, it is set to the MAKE mode even if “BREAK” is displayed.
Sets the length of an alarm operation once an alarm signal has been transmitted. (Unit:second) Setting values: 5s, 6s, 7s, 8s, 9s, 10s, 15s, 20s, 30s or 60s
Sets whether or not manual operation is accepted in case an alarm input is recog- nized during manual operation of the camera. ALARM: Manual operation is not accepted when there is an alarm input.
(Priority on alarm) MANUAL: Manual operation is accepted even when there is an alarm input.
ALARM OUTPUT ..
Sets the configuration of the alarm output terminals on the Ceiling Mount.
Sets the configuration of the Alarm output 1 terminal. OFF: Does not output an alarm signal. ALARM: Alarm signal is output upon input of motion detection or an alarm signal. B&W: Alarm signal is output when the camera enters the B&W mode. PRESET: Alarm signal is output when a camera moves to a preset position. AUX1 to 3: Alarm signal is output when a corresponding AUX signal is input. (This
Sets the configuration of the Alarm output 2 terminal. OFF: Does not output an alarm signal. ALARM: Alarm signal is output upon input of motion detection or an alarm signal. B&W: Alarm signal is output when the camera enters the B&W mode. PRESET: Alarm signal is output when a camera moves to a preset position. AUX1 to 3: Alarm signal is output when a corresponding AUX signal is input. (This
Sets the configuration of the Alarm output 3 terminal. OFF: Does not output an alarm signal. ALARM: Alarm signal is output upon input of motion detection or an alarm signal. B&W: Alarm signal is output when the camera enters the B&W mode. PRESET: Alarm signal is output when a camera moves to a preset position. AUX1 to 3: Alarm signal is output when a corresponding AUX signal is input. (This

This menu sets the picture signal of the camera, such as the color level and contour enhancement.
Function & Setting
Initial Value
COLOUR LEVEL
Sets the color level of the picture signal. To increase: Set a smaller value. To decrease: Set a larger value. Setting values: –5 to NORMAL to 5.
Sets the contour enhancement which controls the sharpness of the monitor pic- ture. To soften the picture: Set a smaller value. To sharpen the picture: Set a larger value. Setting values: –5 to NORMAL to 5.
Sets the pedestal level (black level) of the video signal. To darken the picture: Set a smaller value. To brighten the picture: Set a larger value. Setting values: –5 to NORMAL to 5.
AUTO BLK. CTL
Use this function when darker parts of a picture are unclear even after the gain has been increased using the AGC (Auto Gain Control). ON: When the black level of the video signal is low, the pedestal level is in-
creased automatically in order to improve the clarity of the darker parts. OFF: Turns this function off.
This screen adjusts the settings of automated functions relating to picture brightness.
Function & Setting
Initial Value
Sets the method of exposure detection to the ratio between the average and peak values. Large Average value: Use this setting when areas other than the highlighted ar-
eas are filled with dark. (Example: 10:0) Large Peak value: Use this setting when highlighted areas appear as halation.
SHUTTER
Sets the electronic shutter speed. When the item “SENSE UP” is set to “x2” or higher, the, available settings for the SHUTTER are limited to 1/50 and 1/120. When the item “ExDR MODE” is set to “ON”, the available settings for the SHUT- TER are limited to 1/50 and 1/120. Setting values : 1/50, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000

CAMERA ALC/ExDR Screen (Continued)
Function & Setting
Initial Value
AGC MODE
Sets the maximum gain of the AGC (Auto Gain Control), which electronically in- creases the gain when the object is under low light conditions. OFF: Turns the AGC off. 10 dB: According to the brightness of the object, gain is increased by up to 10 dB 20 dB: According to the brightness of the object, gain is increased by up to 20 dB SUPER: Use this setting when brightness is still insufficient under the “20 dB”
setting.
This function is used to increase the sensitivity by extending the exposure time. When the object is dark, this function sets how high the level of sensitivity will automatically increase to. “x32” means that the sensitivity will be increased con- tinuously up to 32 times the normal level. Increasing this value slows the shutter speed and motion may appear unnatural. When the item “SHUTTER” is set to “1/250” or more, the SENSE UP item does not work and “---“ is displayed as the item name in the CAMERA ALC/ExDR Screen. Setting values: OFF, x2, x4, x8, x16, x24, x32
When an object is dark, this functions sets whether priority during monitoring is placed on maintaining the motion of the camera or on picture quality. MOTION: Motion of the camera is given priority. When an object is dark, the
AGC function is prioritized. This setting is suitable when objects are characterized by quick motion. PICTURE: Picture quality is given priority. When an object is dark, the SENSE UP
function is prioritized. This setting is suitable when picture quality is important.
The ExDR function synthesizes pictures captured at a shutter speed of 1/100 and those captured at higher shutter speeds to help monitor objects having large differ- ences in brightness levels. When the “SHUTTER” function is set to “1/250” or a higher, this function does not work and “---” is displayed as the item name in the CAMERA ALC/ExDR Screen. OFF: Turns the ExDR function off. ON: Turns the ExDR function on.

Function & Setting
Initial Value
ExDR LEVEL
This function sets which section of the object is to be displayed in the easiest-to- view brightness level in the ExDR mode. To make a low-light section of the object easy to view: Increase the level. To make a highlighted section of the object easy to view: Decrease the level. Setting values: –5 to NORMAL to 5
B&W/COLOUR MODE ..
This function sets the color modes to color or B&W. When switching the mode between “color” and “B&W” is carried out, the focus may be dislocated. In such a case adjust the focus again.
Switches the mode from color to B&W and vice-versa. OFF: Turns the B&W mode switching function off. ON: Sets the camera permanently to B&W mode. AUTO: The camera automatically switches to Color mode when the ob-
ject is bright and to B&W mode when it is dark. ALARM IN 1 to 4: The camera switches to B&W mode when there is an alarm
input from terminals Alarm 1 to Alarm 4. The B&W mode is set to ON when the contact is shorted (makes contact) and OFF when the contact is opened (breaks contact).
When the “B&W” function is set to “AUTO”, this function sets the signal level of the object at which the camera will automatically switch to B&W mode. LOW: The camera switches to B&W mode when the signal level of the object
is high.
When the item “B/W” is set to other than AUTO, “---“ is displayed and the settings to the item “LEVEL” cannot be varied.
Use this function to set the type of light illuminating the object in the B&W mode. NORMAL: Setting for normal lighting. IR: Setting for using IR lighting.
MEMO If the IR setting is used under ordinary sunlight or fluorescent light, the switching between the color and B&W modes will not be performed correctly.

HOME MOTION DETECT Screen
When the camera is in the home position: This screen sets the motion detect function, which outputs an alarm signal when motion is detected in the monitored picture. The alarm signal is output from the alarm output terminal on the terminal board.
Function & Setting
Initial Value
MODE
Turns the motion detect function on and off. OFF: Defeats this function. ON: Activates this function.
LEVEL
When the setting value of the detection level is increased, it sometimes causes the fluores- cent lamp to flicker. Check the performance at the DEMONSTRATION item after changing the setting.
AREA EDIT..
Sets of the area of the picture within which the motion detect function operates. P. 33, “HOME MOTION DETECT Setup”
Sets the length of an alarm signal and the alarm display output when motion is detected. When the item “MODE” is set to “OFF”, this item is does not work and “---” is dis- played as the item name in the HOME MOTION DETECT Screen. Setting values: OFF, 5s, 6s, 7s, 8s, 10s, 15s, 20s, 30s, 60s
When the item “MODE” is set to OFF, an alarm signal is output from the alarm output termi- nal but the alarm display is not shown in the picture.
This function is used to confirm the setup of the motion detect function.

This screen sets up the auto pan function for slow panning, the auto patrol function for switching of positions in sequence, and the auto trace function for the reproduction of the results of manual camera operations.
Function & Setting
Initial Value
Determines movement during auto panning. RETURN: Moves continuously between start and return positions. RIGHT: Clockwise rotation LEFT: Counterclockwise rotation. P. 34, “AUTO PAN Setup”
Sets the rotation speed during auto panning. LOW: Low speed. NORMAL: Normal speed. HIGH: High speed.
A. PAN START POS. SET..
Sets the auto panning start position.
A. PAN RETURN POS. SET..
Sets the auto panning return position.
Sets the configuration of the auto patrol function. P. 35, “AUTO PATROL Setup”
Sets the configuration of the auto trace function. P. 36, “AUTO TRACE Setup”
Determines the function activated by pressing the AUTO PAN button on the remote control unit. A. PAN: Auto pan function. A. PATROL: Auto patrol function. A. TRACE: Auto trace function.
Determines the function activated by pressing the AUTO PATROL button on the re- mote control unit. A. PAN: Auto pan function. A. PATROL: Auto patrol function. A. TRACE: Auto trace function.

POSITION FUNCTION SET Screen
This screen sets the configurations of functions relating to pictures taken in preset positions.
Function & Setting
Initial Value
POSITION TITLE..
Sets the titles for the 99 preset positions and the home position. Titles can be up to 16 characters in length and are shown in the display. P. 37, “POSITION TITLE Setup”
Determines the lens iris adjustment mode. AUTO: for auto iris adjustment under standard conditions. AUTO+: for auto iris adjustment under slightly brighter conditions. AUTO–: for auto iris adjustment under slightly dimmer conditions. MANUAL: for manual iris adjustment.
BLC
Sets of area of back light compensation. Use this function when the object ap- pears dark (under auto iris control) because of the presence of a bright light source behind it. This function make it possible to place the unnecessary light source out- side the photometry area.
OFF AREA 1 AREA 2 AREA 3 AREA 4
When the item “ExDR MODE” ( page 24) is set to ON, the item “BLC” is set to OFF and “---” is displayed. Under this condition, the settings to the item “BLC” cannot be varied.
Determines the setting of the white balance adjustment. The white balance can be adjusted for lighting conditions with color temperatures from 2500K to 8000K. ATW: Auto-Tracking White balance mode, adjusts the white balance automati-
cally according to the color temperature of the lighting conditions. When ATW is set, “---“ is displayed for the items “R-B GAIN” and “M-G GAIN”, so that the color phase adjustment cannot be carried out. AWC: Auto White Control mode, which displays “PUSH SET → ADJ. STRAT”.
When the SET button is pressed, AWC is activated and thet white balance adjustment starts. If the AWC is activated while the screen is B&W the LOW LIGHT ERROR will be displayed. This is not abnormal.
This screen resets values to their factory settings.
Function & Setting
Initial Value
FACTORY SETTINGS
Resets all settings in the above menus to their initial factory settings. Pressing the SET button displays “EXECUTING” (2 sec. approx.) and resets the settings to the factory settings. CANCEL: Does not alter current values. CLEAR (W/O POS. TITLE): Resets the settings to the initial, factory settings.
However, the set positions, the setting data of each position and the titles are not reset to the factory set- tings. CLEAR (ALL): Resets all settings including titles and stored positions.

Use the PRIVATE MASK screen to set up the private mask function, which grays out areas that are not required to be included in the monitored picture. Up to four private masks can be set per screen, and up to eight private masks can be set in total.


P O S . T I T L E L O C . U P - L – – – C A M E R A F U N C T I O N – – –
F L I P D I G I T A L V A R . P / T S P E E D O N E A S Y A F O F F D . Z O O M M A X X 2 P R I V A T E M A S K . .
M O D E O N – – – P R I V A T E M A S K – – –
M A S K N O 1* M A S K E D I T . . M A S K D E L E T E . .
Already set.

– – – M A S K E D I T – – –
P U S H M E N U S A V E & R E T U R N →
– – – M A S K D E L E T E – – –

CAMERA TITLE Setup
Use the CAMERA TITLE screen to set the title of each camera. Titles can be up to 16 characters in length and are displayed at the bottom left of the picture.

– – – M E N U – – –
C A M . F U N C T I O N . .
C A M . T I T L E / A L A R M . . C A M . V I D E O A D J U S T . . C A M . A L C / E x D R . . H O M E M O T I O N D E T E C T . . A U T O P A N / P A T R O L / T R A C E . . P O S I . F U N C T I O N S E T . . F A C T O R Y S E T T I N G S . .
C A M . T I T L E E D I T . . – – – C A M E R A T I T L E / A L A R M – – –
A R E A T I T L E O F F A R E A T I T L E E D I T . . A L M . T I T L E S I Z E D O U B L E A L M . T I T L E C O L O U R WH I T E A L A R M T I T L E E D I T . . A L A R M I N P U T . . A L A R M O U T P U T . .
0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K – – – C A M E R A T I T L E – – –
L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z . , ' – : / Ä Ö Ü Â Ê Î Ô Û Ç Ñ ä ë ï ö ü â ê î ô û á é í ó ú à è ì ò ù ç ñ ß ¡ ¿
←W I D E T E L E →
Title input field Blinking

The 360° panning range of the camera can be divided into 16 equally sized areas and an area title can be set for each area. Titles can be of up to 16 characters in length and are displayed in the picture as the camera is panned manually. (Area title display ON/OFF: P. 21, Item “AREA TITLE”. Area title display position P. 20, Item “POS. TITLE. LOC.”)

– – – M E N U – – –
C A M . F U N C T I O N . .
C A M . T I T L E / A L A R M . . C A M . V I D E O A D J U S T . . C A M . A L C / E x D R . . H O M E M O T I O N D E T E C T . . A U T O P A N / P A T R O L / T R A C E . . P O S I . F U N C T I O N S E T . . F A C T O R Y S E T T I N G S . .
C A M . T I T L E E D I T . . – – – C A M E R A T I T L E / A L A R M – – –
A R E A T I T L E O F F A R E A T I T L E E D I T . . A L M . T I T L E S I Z E D O U B L E A L M . T I T L E C O L O U R WH I T E A L A R M T I T L E E D I T . . A L A R M I N P U T . . A L A R M O U T P U T . .
0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K – – – A R E A T I T L E 1 – – –
L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z . , ' – : / Ä Ö Ü Â Ê Î Ô Û Ç Ñ ä ë ï ö ü â ê î ô û á é í ó ú à è ì ò ù ç ñ ß ¡ ¿
←W I D E T E L E →
T I T L E N O . S E L E C T → F O C U S

ALARM TITLE Setup
Use the ALARM TITLE screen to set the alarm titles to be displayed when an alarm signal is transmitted. Up to 10 alarm titles (ALARM TITLE 1 to 10) can be set and each title can be up to 12 characters in length.

– – – M E N U – – –
C A M . F U N C T I O N . .
C A M . T I T L E / A L A R M . . C A M . V I D E O A D J U S T . . C A M . A L C / E x D R . . H O M E M O T I O N D E T E C T . . A U T O P A N / P A T R O L / T R A C E . . P O S I . F U N C T I O N S E T . . F A C T O R Y S E T T I N G S . .
C A M . T I T L E E D I T . . – – – C A M E R A T I T L E / A L A R M – – –
A R E A T I T L E O F F A R E A T I T L E E D I T . . A L M . T I T L E S I Z E D O U B L E A L M . T I T L E C O L O U R WH I T E A L A R M T I T L E E D I T . . A L A R M I N P U T . . A L A R M O U T P U T . .
0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K – – – A L A R M T I T L E 1 – – –
L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z . , ' – : / Ä Ö Ü Â Ê Î Ô Û Ç Ñ ä ë ï ö ü â ê î ô û á é í ó ú à è ì ò ù ç ñ ß ¡ ¿
←W I D E T E L E →
T I T L E N O . S E L E C T → F O C U S

RM-P2580 units need to be configured to display Alarm Titles. Use the RM-P2580 menu settings to do this:

Use the HOME MOTION DETECT screen to set the areas to be excluded from the target area of the motion detect function. (which outputs an alarm upon detection motion in the monitored picture)

– – – M E N U – – –
C A M . F U N C T I O N . .
C A M . T I T L E / A L A R M . . C A M . V I D E O A D J U S T . . C A M . A L C / E x D R . . H O M E M O T I O N D E T E C T . . A U T O P A N / P A T R O L / T R A C E . . P O S I . F U N C T I O N S E T . . F A C T O R Y S E T T I N G S . .
M O D E O F F – – – H O M E M O T I O N D E T E C T – – –
L E V E L – – – A R E A E D I T . . A L A R M D I S P L A Y 5 s D E M O N S T R A T I O N . .
The positions of areas in the picture are reference positions. Check the actu- al positions in the actual picture. The areas set to be excluded from the motion detection target area can be confirmed in the DEMONSTRATION screen.
– – – D E M O N S T R A T I O N – – –
The motion detect function is not intended to prevent fire or theft. There- fore, JVC will not assume any liabilities for accidents and damage relat- ed to the use of this function.

AUTO PAN Setup
Use the AUTO PAN screen to set the auto pan function, which allows the camera to be revolved slowly in a horizontal direction) The auto pan function has three modes, the RETURN mode for continual movement between two positions, the RIGHT mode for clock-wise rotation and the LEFT mode for counterclockwise rotation.

A U T O P A N M O D E R E T U R N – – – A U T O P A N / P A T R O L / T R A C E – – –
A U T O P A N S P E E D N O R M A L A . P A N S T A R T P O S . S E T . . A . P A N R E T U R N P O S . S E T . . A U T O P A T R O L S E T . . A U T O T R A C E S E T . . R M A . P A N K E Y A . P A N R M A . P A T R O L K E Y A . P A T R O L
– – – S T A R T P O S I T I O N S E T – – –
P U S H M E N U / S A V E & R E T U R N /
– – – R E T U R N P O S I T I O N S E T – – –
After the above setup, auto panning of the camera can be started by pressing the AUTO PAN button on the RM-P2580. “Auto Panning” in the RM-P2580 Instruction manual.
N R U T E R & E V A S / U N E M H S U P
NEAR button

Use the AUTO PATROL screen to set the configuration of the auto patrol function, which moves the camera between several positions at a high speed. Patrol positions 1-100 can be set in each of three modes (MODES 1 to 3). It is recommended that these three modes be set the according to the day of the week or the time of day. For example: MODE 1 for nighttime and MODE 2 for daytime.

A U T O P A N M O D E R E T U R N – – – A U T O P A N / P A T R O L / T R A C E – – –
A U T O P A N S P E E D N O R M A L A . P A N S T A R T P O S . S E T . . A . P A N R E T U R N P O S . S E T . . A U T O P A T R O L S E T . . A U T O T R A C E S E T . . R M A . P A N K E Y A . P A N R M A . P A T R O L K E Y A . P A T R O L
P A T RO L 1 HOME 1 0 s A U T O P A T RO L MOD E 1
P A T RO L 2 P O S 1 1 0 s P A T RO L 3 P O S 2 1 0 s P A T RO L 4 P O S 3 1 0 s P A T RO L 5 P O S 4 1 0 s P A T RO L 6 P O S 5 1 0 s P A T RO L 7 P O S 6 1 0 s P A T RO L 8 P O S 7 1 0 s
F WD / B WD / Z O O M M O D E / F O C U S
P A T RO L 9 P O S 8 1 0 s A U T O P A T RO L MOD E 1

P A T RO L 1 0 P O S 9 1 0 s P A T RO L 1 1 P O S 1 0 1 0 s P A T RO L 1 2 P O S 1 1 1 0 s P A T RO L 1 3 P O S 1 2 1 0 s P A T RO L 1 4 P O S 1 3 1 0 s P A T RO L 1 5 P O S 1 4 1 0 s P A T RO L 1 6 P O S 1 5 1 0 s
F WD / B WD / Z O O M M O D E / F O C U S

AUTO TRACE Setup

– – – M E N U – – –
C A M . F U N C T I O N . .
C A M . T I T L E / A L A R M . . C A M . V I D E O A D J U S T . . C A M . A L C / E x D R . . H O M E M O T I O N D E T E C T . . A U T O P A N / P A T R O L / T R A C E . . P O S I . F U N C T I O N S E T . . F A C T O R Y S E T T I N G S . .
A U T O P A N M O D E R E T U R N – – A U T O P A N / P A T R O L / T R A C E – –
A U T O P A N S P E E D N O R M A L A . P A N S T A R T P O S . S E T . . A . P A N R E T U R N P O S . S E T . . A U T O P A T R O L S E T . . A U T O T R A C E S E T . . R M A . P A N K E Y A . P A N R M A . P A T R O L K E Y A . P A T R O L
– – – A U T O T R A C E S E T – – –
P U S H S E T → L E A R N
– – – A U T O T R A C E S E T – – –
RM-P2580 units need to be configured to use replay movements stored by the Auto Trace func- tion Use the AUTO PAN or AUTO TRACE buttons on the RM-P2580 to do this:
To let the camera execute reproduction of the auto trace operation, it is required to set the auto trace function in the AUTO PAN or AUTO TRACE button of the RM-P2580. P. 27, Items “RM. A. PAN KEY” and “RM. A. PATROL KEY”. When the button to which the auto trace function is set is pressed, the lamp in the button lights up and auto trace reproduction starts. The auto trace reproduction will repeat continually with a pause of 30 seconds between each operation. To end the auto trace reproduction, press the button to which the auto trace function is set again so that the lamp in the button turns off.

Use the POSITION TITLE screen to set the title of each camera position. Each camera position can be given a title of up to 16 characters.

setup.>
– – – M E N U – – –
C A M . F U N C T I O N . .
C A M . T I T L E / A L A R M . . C A M . V I D E O A D J U S T . . C A M . A L C / E x D R . . H O M E M O T I O N D E T E C T . . A U T O P A N / P A T R O L / T R A C E . . P O S I . F U N C T I O N S E T . . F A C T O R Y S E T T I N G S . .
P O S I T I O N T I T L E . . – – – P O S I F U N C T I O N S E T – – –
I R I S M O D E A U T O B L C O F F W . B A L A N C E A T W R - B G A I N – – – M - G G A I N – – –
0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K – – P O S I T I O N T I T L E – –
L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z . , ' – : / Ä Ö Ü Â Ê Î Ô Û Ç Ñ ä ë ï ö ü â ê î ô û á é í ó ú à è ì ò ù ç ñ ß ¡ ¿
←W I D E T E L E →
Title input field Blinking

Attaching a Ceiling Flush Mount Bracket (Optional WB-S575)
The ceiling flush mount bracket (optional WB-S575) allows the camera to be installed flush with the ceiling surface. In this case the ceiling material should have a thickness of between 5 mm and 31 mm.

Mount screws (x 4)

(1) Fit the Ceiling Flush Mount Bracket into the hole in the ceiling.
ceiling plate.
(3) Push the Ceiling Flush Mount Bracket all the way up and tight-
en the three clamping screws (by turning them clockwise).
If anchor bolts can be used, attach them using M8 - M10 (or 3/8 inch) nuts.

Anchor bolt mount holes

Ceiling flush mount bracket attached to the ceiling

Both the ceiling flush mount bracket and the drop prevention attachment should be insulated from the ceiling structure. If the ceiling structure is made of a metallic material, an improper insulation with the camera may produce noise in the video.
Ceiling mount · Ceiling panel

Removing a Ceiling Flush Mount Bracket (Optional WB-S575)

<Check the release labels thoroughly before removal.> 1. Remove the ceiling panel. Pull the ceiling panel and disengage the two hooks.
Push the stopper release lever upwards with a screwdriver, etc. Release label
Stoppers

Picture is not displayed.
Is there a problem in the power cable(s) connecting the camera to the power supply unit? (If the power cable(s) are too long or of an inadequate size, the correct voltage may not be supplied due to an increase in cable resistance.)
Use cable(s) with low cable resistance and of the correct cable length. (Ensure that the voltage supplied to the terminal board is correct during camera operation, i.e. when the rated current is flowing through the camera.)
Power cannot be turned on.
Are cables connected properly to the terminal board on the Ceiling Mount ?
Connect the cables properly.
Power can be turned on but it later turns off when the pan/tilt mechanism starts operation.
Is there a problem with the power cable(s) connecting the camera to the power supply unit? (If the power cable(s) are too long or of an inadequate size, the correct voltage may not be supplied due to an increase in cable resistance during the pan/tilt operation.)
Change power cable(s) to one(s) of lower resistance (i.e. thicker or shorter cable(s)). ( P. 14)
Video sync error occurs.
When L/L is set, does the power supply frequency match the video frequency (50 Hz)?
Use a stable power supply with a matching frequency.
Is a large noise interfered with the power supply?
Prevent any penetration of noise in the power supply.

Specifications
I Pan/Tilt Mechanism
Image pickup device : 1/4 type, interline transfer CCD,
Panning range : 360° endless revolution
752(H) x 582(V) pixels.
Sync system : Line Lock, Internal
Tilting range : 0° to 180° (Horizontal – Straight
Scanning frequencies : Horizontal 15.625 kHz,
downward – Horizontal)
Vertical 50 Hz
Tilting speed : 1°/s to 180°/s
S/N : 50 dB (typical), (AGC OFF,
ENHANCE –5)
I General
Minimum object : Color mode: illumination 1.8 lx (50% output, AGC 20 dB, WIDE end) 0.06 lx (50% output, AGC 20 dB, WIDE end, electronic sense up x32) 0.5 lx (25% output, AGC 20 dB, WIDE end, electronic sense up x2) B&W mode: 0.05 lx (50% output, AGC 20 dB, WIDE end)
Number of preset positions : 100
Applicable remote control unit : RM-P2580
Control signal connection terminal : EIA RS-485 compliant, 9600 bit/sec.
0°C to 40°C (recommended)
Ambient humidity : 35% to 90%RH (without conden-
sation)
Dynamic range : 52 dB (ExDR mode)
Drip-proof property : IEC529
White balance : TTL auto tracking/Manual
Mass : 2.4 k ˝
Electronic shutter : 1/50 sec. (standard), 1/120 sec.
Back light compensation : Possible by selecting 4 photome-
Ceiling mount 1 Screw (M3 x 12 mm) 1 Screw (M4 x 12 mm) 4 Cable plate 1 4P alarm cable 1 6P alarm cable 1 (ENHANCE)
Color level adjustment : Possible
Contour correction : Both Horizontal and Vertical (level
adjustable)
I Lens
Zoom ratio : Approx. x27 (Approx. x270 with
electronic zooming)
Focal distance : 3.8 mm to 103 mm
Maximum aperture : F1.4 (WIDE) to F3.0 (TELE)

![JVC TK-C676 — I External dimensions [Unit: mm] I Ceiling mount hole diagram (page 43)](/cdn/reader/d5/d506d83b540e9a3fe4237af6024e18c34e4dcb03a085fce36d8938c222dc0956/images/fig-43-1.webp)
![JVC TK-C676 — I External dimensions [Unit: mm] I Ceiling mount hole diagram (page 43)](/cdn/reader/d5/d506d83b540e9a3fe4237af6024e18c34e4dcb03a085fce36d8938c222dc0956/images/fig-43-2.webp)
(Ceiling flush mount bracket + Ceiling panel) I Dimensions in combination with the WB-S575

200 (Hole making size)

* Design and specifications are subject to be changed without notice.

is a registered Trademark owned by VICTOR COMPANY OF JAPAN, LTD.
is a registered Trademark in JAPAN, the U.S.A., the U.K. and many other countries.
Printed in Thailand LWT0003 © 2001 VICTOR COMPANY OF JAPAN, LIMITED
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| IP52 | standard. The maximum diameter of the pipe con- | p.14 |
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Picture is not displayed. | Is there a problem in the power cable(s) connecting the camera to the power supply unit? (If the power cable(s) are too long or of an inadequate size, the correct voltage may not be supplied due to an increase in cable resistance.) | Use cable(s) with low cable resistance and of the correct cable length. (Ensure that the voltage supplied to the terminal board is correct during camera operation, i.e. when the rated current is flowing through the camera.) | p.41 |
| Power cannot be turned on. | Are cables connected properly to the terminal board on the Ceiling Mount ? | Connect the cables properly. | p.41 |
| Power can be turned on but it later turns off when the pan/tilt mechanism starts operation. | Is there a problem with the power cable(s) connecting the camera to the power supply unit? (If the power cable(s) are too long or of an inadequate size, the correct voltage may not be supplied due to an increase in cable resistance during the pan/tilt operation.) | Change power cable(s) to one(s) of lower resistance (i.e. thicker or shorter cable(s)). ( P. 14) | p.41 |
| Video sync error occurs. | When L/L is set, does the power supply frequency match the video frequency (50 Hz)? Is a large noise interfered with the power supply? | Use a stable power supply with a matching frequency. Prevent any penetration of noise in the power supply. | p.41 |