AMX ™ 68000 Target Guide

First Printing: April 15, 1994 Last Printing: March 1, 2005

Copyright © 1994 - 2005

KADAK Products Ltd. 206 - 1847 West Broadway Avenue Vancouver, BC, Canada, V6J 1Y5

Phone(604) 734-2796 Fax: (604) 734-8114
Page 2 of the AMX Software (Target Guide) user manual — Cover
Page 2 · click to enlarge
Page 2
Page 2 of the AMX Software (Target Guide) user manual — Cover
Page 3 of the AMX Software (Target Guide) user manual — TECHNICAL SUPPORT
Page 3 · click to enlarge
Page 3

TECHNICAL SUPPORT

KADAK Products Ltd. is committed to technical support for its software products. Our programs are designed to be easily incorporated in your systems and every effort has been made to eliminate errors.

Engineering Change Notices (ECNs) are provided periodically to repair faults or to improve performance. You will automatically receive these updates during the product's initial support period. For technical support beyond the initial period, you must purchase a Technical Support Subscription. Contact KADAK for details. Please keep us informed of the primary user in your company to whom update notices and other pertinent information should be directed.

Should you require direct technical assistance in your use of this KADAK software product, engineering support is available by telephone, fax or e-mail. KADAK reserves the right to charge for technical support services which it deems to be beyond the normal scope of technical support.

We would be pleased to receive your comments and suggestions concerning this product and its documentation. Your feedback helps in the continuing product evolution.

KADAK Products Ltd. 206 - 1847 West Broadway Avenue Vancouver, BC, Canada, V6J 1Y5

Phone(604) 734-2796 Fax: (604) 734-8114 e-mail: amxtech@ kadak.com

AMX 68000 Target Guide KADAK i

Page 4 of the AMX Software (Target Guide) user manual — TRADEMARKS
Page 4 · click to enlarge
Page 4

Copyright © 1994-2005 by KADAK Products Ltd.

All rights reserved.

No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of KADAK Products Ltd., Vancouver, B.C., CANADA.

DISCLAIMER

KADAK Products Ltd. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability and fitness for any particular purpose. Further, KADAK Products Ltd. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of KADAK Products Ltd. to notify any person of such revision or changes.

TRADEMARKS

AMX in the stylized form and KwikNet are registered trademarks of KADAK Products Ltd. AMX, AMX/FS, InSight, KwikLook and KwikPeg are trademarks of KADAK Products Ltd. Microsoft, MS-DOS and Windows are registered trademarks of Microsoft Corporation. All other trademarked names are the property of their respective owners.

ii KADAK AMX 68000 Target Guide

Page 7 of the AMX Software (Target Guide) user manual — AMX Tool Guides
Page 7 · click to enlarge
Page 7

1. Getting Started with AMX 68000

1.1 Introduction

The AMX™ Multitasking Executive is described in the AMX User's Guide. This target guide describes AMX 68000 which operates on the Motorola MC680xx, MC683xx and all architecturally compatible processors.

Throughout this manual, the term M68000 refers specifically to the Motorola MC680xx and MC683xx families of processors and all processors which are exact replicas. When distinctions are not important, the term M68000 is used to reference any processor which has the general characteristics of these families. When distinctions are important, the processors are identified explicitly.

The purpose of this manual is to provide you with the information required to properly configure and implement an AMX 68000 real-time system. It is assumed that you have read the AMX User's Guide and are familiar with the architecture of the M68000 processor.

Installation

AMX 68000 is delivered ready for use on a PC or compatible running Microsoft® Windows®. To install AMX, follow the directions in the Installation Guide. All AMX files required for developing an AMX application will be installed on disk in the directory of your choice. All AMX source files will also be installed on your disk.

AMX Tool Guides

This manual describes the use of AMX in a tool set independent fashion. References to specific assemblers, compilers, librarians, linkers, locators and debuggers are purposely omitted. For each tool set with which AMX 68000 has been tested by KADAK, a separate chapter in the AMX Tool Guide is provided.

AMX 68000 Target Guide KADAK 1

Page 8 of the AMX Software (Target Guide) user manual — File Name Module
Page 8 · click to enlarge
Page 8

1.2 AMX Files

AMX is provided in C source format to ensure that regardless of your development environment, your ability to use and support AMX is uninhibited. AMX also includes a small portion programmed in M68000 assembly language.

Figures 1.2-1, 2 and 3 summarize the AMX modules provided with AMX 68000. The AMX product manifest (file MANIFEST.TXT) is a text file which indicates the current AMX revision level and lists the AMX modules which are provided with the product.

File Name Module

CJ532 .H Generic include file CJ532APP.H Custom application definitions CJ532CC .H C dependent definitions CJ532EC .H AMX error code definitions CJ532IF .H C and target interface prototypes CJ532KC .H Private AMX constants CJ532KF .H AMX service procedure prototypes CJ532KP .H Private AMX prototypes CJ532KS .H Private AMX structure definitions CJ532KT .H Target processor definitions CJ532KV .H AMX version specification CJ532SD .H AMX application structure definitions CJ532TF .H Target dependent prototypes

CJZZZ .H Copy of generic include file CJ532.H used for portability

CHxxxxx .H Definitions for common timer (PIT, TPU) and serial I/O (UART) chips

Figure 1.2-1 AMX Include Files

File Name Module

CJ532K .DEF Private AMX assembly language definitions CJ532KQ .ASM Private AMX math procedures CJ532KR .ASM AMX Interrupt Supervisor CJ532KS .ASM AMX Task Scheduler CJ532MXA.ASM Message Exchange Manager constants CJ532TDC.ASM Time/Date Manager constants CJ532UA .ASM Target processor and C support (part 1) CJ532UB .ASM Target processor and C support (part 2)

Figure 1.2-2 AMX Assembler Source Files

2 KADAK AMX 68000 Target Guide

Page 9 of the AMX Software (Target Guide) user manual — File Name Module
Page 9 · click to enlarge
Page 9

File Name Module

CJ532KA .C Kernel task services CJ532KB .C General task services CJ532KBR.C CJ532KC .C Timer Manager CJ532KCR.C CJ532KD .C Task management services CJ532KDR.C CJ532KE .C Task termination services CJ532KF .C Suspend/resume task CJ532KG .C Time slice services CJ532KH .C Task status CJ532KI .C Enter and Exit AMX CJ532KJ .C General object access CJ532KK .C AMX Vector Table access CJ532KL .C Private AMX list manipulation CJ532KM .C AMX task scheduler hook services CJ532KX .C AMX Kernel Task

CJ532CL .C Circular List Manager CJ532LM .C Linked List Manager

CJ532BM .C Buffer Manager CJ532BMR.C CJ532EM .C Event Manager CJ532EMR.C CJ532RM .C Semaphore Manager (resources) CJ532SM .C Semaphore Manager CJ532SMR.C CJ532MB .C Mailbox Manager CJ532MBR.C CJ532MF .C Flush mailbox and message exchange CJ532MM .C Memory Manager CJ532MMR.C CJ532MX .C Message Exchange Manager CJ532MXR.C

CJ532TDA.C Time/Date Manager CJ532TDB.C Time/Date formatter

CJ532UF .C Launch and leave AMX

CJ532XTA.C Message exchange task services CJ532XTB.C Message exchange task termination

CHxxxxxT.C Clock drivers for common timer (PIT, TPU) chips CHxxxxxS.C Sample drivers for common serial I/O (UART) chips

Figure 1.2-3 AMX C Source Files

AMX 68000 Target Guide KADAK 3

Page 10 of the AMX Software (Target Guide) user manual — 1.3 AMX Nomenclature
Page 10 · click to enlarge
Page 10

1.3 AMX Nomenclature

The following nomenclature standards have been adopted throughout the AMX Target Guide.

Numbers used in this manual are decimal unless otherwise indicated. Hexadecimal numbers are indicated in the format 0xABCD or $ABCD.

The terminology A(Table XYZ) is used to define addresses. It is read as "the address of Table XYZ".

Read/write memory is referred to as RAM. Read only memory (non-volatile storage) is referred to as ROM.

AMX symbol names and reserved words are identified as follows:

cjkkpppp AMX C procedure name pppp for service of class kk cjxtttt AMX structure name of type tttt xttttyyy Member yyy of an AMX structure of type tttt

CJ_ID AMX object identifier (handle) CJ_ERRST Completion status returned by AMX service procedures CJ_CCPP Procedures use C parameter passing conventions CJ_ssssss Reserved symbols defined in AMX header files

CJ_ERxxxx AMX Error Code xxxx CJ_WRxxxx AMX Warning Code xxxx CJ_FExxxx AMX Fatal Exit Code xxxx

CJ532xxx.xxx AMX 68000 filenames CJZZZ.H Generic AMX include file

The generic include file CJZZZ.H is a copy of file CJ532.H which includes the subset of the AMX 68000 header files needed for compilation of your AMX application C code. By including the file CJZZZ.H in your source modules, your AMX application becomes readily portable to other target processors.

Throughout this manual code examples are presented in lower case. File names are shown in upper case. C code assumes that an int is 32 bits as is common for most C compilers for the M68000 processor.

Processor registers are referenced using the software names specified by Motorola.

D0, D1, D2, D3, D4, D5, D6, D7 A0, A1, A2, A3, A4, A5, A6, A7 PC, SP = A7 SR = status register, CC = flags (condition code)

4 KADAK AMX 68000 Target Guide

Page 11 of the AMX Software (Target Guide) user manual — Symbol Purpose
Page 11 · click to enlarge
Page 11

1.4 AMX 68000 Target Specifications

AMX 68000 was initially developed and tested using the Motorola MC68020, MC68040 and MC68332 processors on a variety of Motorola evaluation boards. However, the AMX 68000 design criteria fully encompass the Motorola M68000 processor family requirements.

AMX uses a set of design constants which vary according to the constraints imposed by each target processor. When operating on the M68000 processor, these design constants assume the values listed in Figure 1.4-1.

Symbol Purpose

CJ_CCISIZE Size of integer is 4 bytes (32 bits) Event group supports 32 event flags per group CJ_ID AMX id (handle) is a 32 bit unsigned integer CJ_ERRST AMX error codes are 32 bit signed integers

CJ_MINMSZ Minimum AMX message size is 12 bytes CJ_MAXMSZ Default AMX message size is 12 bytes CJ_MINKG Minimum number of AMX message envelopes is 10

CJ_MINKS Minimum Kernel Stack is 256 bytes CJ_MINIS Minimum Interrupt Stack is 256 bytes CJ_MINTKS Minimum task storage (including TCB) is 512 bytes

CJ_MINBFS Minimum AMX buffer size is 8 bytes CJ_MINUMEM Minimum AMX memory block size is 16 bytes CJ_MINSMEM Minimum AMX memory section size is 128 bytes

Figure 1.4-1 AMX Design Constants

AMX 68000 Target Guide KADAK 5

Page 12 of the AMX Software (Target Guide) user manual — Interrupt State
Page 12 · click to enlarge
Page 12

1.5 Launch Requirements

The M68000 must be properly configured for use before AMX is launched. The manner in which this is accomplished will depend on your target hardware implementation and on the startup code provided with your C compiler.

AMX does not include bootstrap code to initialize the M68000 processor. It is assumed that you will have a boot ROM present which configures the M68000 for your specific hardware configuration and begins program execution at the entry to your C startup code.

During development, you may be using a ROM monitor provided by the processor vendor or by the toolset supplier. The ROM monitor automatically initializes the processor at power on. The monitor is then used to download your AMX application and start execution at the entry point to the C startup code. Eventually your main C program is called and AMX can be launched by your call to cjkslaunch.

Once your application has been tested, you may choose to replace the ROM monitor and the C startup code with your own initialization code. The manner in which you do this is outside the scope of this manual.

Operating Mode

AMX requires that the processor be set to supervisor mode. The processor is in supervisor mode when the supervisor/user state bit S is 1 in the status register (SR). This is the default state when the processor is reset.

Interrupt State

Interrupts can be enabled or disabled on entry to AMX. Set the interrupt priority mask in the status register to disable (0x0600) or enable (0x0000) external interrupts. AMX will disable interrupts during its startup initialization. AMX will enable interrupts prior to calling your application Restart Procedures.

If you launch AMX with interrupts enabled, be sure that all interrupt sources are either disabled or externally masked off. You must not enable or unmask any interrupt source until you have installed an AMX Interrupt Service Procedure to properly service the device. This subject is described in more detail in Chapters 3 and 4.

For the MC68020, MC68030, MC68040, MC68060 and architecturally similar processors, AMX requires that the processor be set to interrupt mode. The processor is in interrupt mode when the master/interrupt state bit M is 0 in the status register (SR). This is the default state when the processor is reset.

Some M68000 processors include a Vector Base Register (VBR) which must be initialized with the address of the Exception Vector Table. AMX can be configured to do this initialization at launch time. Alternatively you can initialize the VBR prior to launching AMX and allow AMX to read the VBR without modifying it.

6 KADAK AMX 68000 Target Guide

Page 13 of the AMX Software (Target Guide) user manual — Instruction and Data Caching
Page 13 · click to enlarge
Page 13

Trace Controls

AMX alters the state of the status register (SR) whenever it enables or disables interrupts. When AMX disables interrupts, it also clears the trace control bits (T or T0 and T1) to 0. When AMX enables interrupts, the trace control bits remain unaltered. Consequently, you may not be able to use your debugger to single step trace through private AMX code sequences.

M68000 Stack Use

The M68000 begins execution in supervisor mode (and interrupt mode for the MC68020, MC68030, MC68040, MC68060, et al) using the initial interrupt stack specified by vector number 0 in the Exception Vector Table. Your bootstrap code or C startup code may switch to an alternate stack. Once AMX is launched, it abandons the startup stack. AMX only uses the stacks allocated by you in your AMX System Configuration Module. To accomplish this feat on processors which support multiple stacks, AMX always executes in the interrupt mode (M = 0 in SR).

Instruction and Data Caching

The MC68020 includes a 256-byte instruction cache but no data cache. The MC68030 includes a 256-byte instruction cache and a 256-byte data cache. The MC68040 includes a 4096-byte instruction cache and a 4096-byte data cache. The MC68060 includes an 8192-byte instruction cache and an 8192-byte data cache.

If your AMX Target Parameter File (see Chapter 4) targets one of these processors, AMX will automatically flush and enable both caches when AMX is launched. Alternatively, you can configure AMX to ignore the caches during the launch. AMX provides procedures which you can use to enable or disable the caches.

For example, if you disable both caches in your main program and configure AMX to ignore the cache, you can simplify the initial testing of your application or overcome caching problems which may be encountered if your debugger cannot properly handle cached operation.

You must be aware that, on processors which utilize an M68000 Memory Management Unit (MMU), successful cache operation will depend on proper setup of the MMU. For example, if the MMU does not properly control cached access to memory and devices, you may find that device I/O reads and writes end up being cached, resulting in failure of the device to operate as expected.

AMX does not manipulate the MMU. If you configure AMX to enable caching during the launch, then you must ensure that the MMU is properly initialized to meet your hardware memory addressing specifications prior to launching AMX. The AMX Sample Program purposely leaves the caches unaltered to avoid possible cache related problems during your initial use of AMX in your hardware environment.

AMX 68000 Target Guide KADAK rev6 7

Page 14 of the AMX Software (Target Guide) user manual — Big or Little Endian
Page 14 · click to enlarge
Page 14

Memory Management Unit (MMU)

The MC68030, MC68040, MC68LC040 and MC68060 include a Memory Management Unit (MMU) to support a demand-paged virtual memory environment. AMX does not support the M68000 memory management unit.

If you are using AMX on the Motorola MC68000, MC68008, MC68010 or MC683xx processors, this restriction does not apply. These processors do not implement the M68000 memory management unit and allow direct access to the full 20, 24 or 32-bit address space supported by the particular processor.

Your AMX application code and data must reside within the memory address ranges allowed by the particular M68000 processor which you are using. The M68000 MMU, if present, must be setup prior to launching AMX. In most cases, your boot ROM or C startup code will configure the M68000 MMU for your specific hardware configuration prior to entry to your main() program.

Do not enable the memory caches if the MMU has not been initialized to provide proper cached access to memory.

Big or Little Endian

AMX 68000 adheres to the big endian model in which the most significant byte of a word (long) is stored in the lowest byte address.

Be aware that AMX for other processors may be big or little endian. If you intend to port your AMX application to other processors, then avoid using coding techniques which are endian dependent.

8 KADAK AMX 68000 Target Guide

Page 15 of the AMX Software (Target Guide) user manual — 2. Program Coding Specifications
Page 15 · click to enlarge
Page 15

2. Program Coding Specifications

2.1 Task Trap Handler

AMX 68000 supports task traps for the M68000 zero divide, bounds check and overflow faults. A zero divide fault occurs if any M68000 instruction attempts an integer division by zero. A bounds check fault occurs if the M68000 CHK instruction detects an array bound violation. An overflow fault occurs if the overflow flag (V) is set in the status register (SR) at the time an M68000 TRAPV instruction is executed.

The Task Trap Handler can be written as a C procedure with formal parameters.

#include "CJZZZ.H" /* AMX Headers */

void CJ_CCPP traphandler( struct cjxregs *regp, /* A(Register Structure) */ void *faultfp) /* A(Fault frame) */ {

: Process the error : }

The zero divide, bounds check and overflow exceptions are serviced by AMX. The state of each register at the time of the fault is stored on the stack in an AMX register structure cjxregs. Parameter regp is a pointer to that structure. Structure cjxregs is defined in AMX header file CJ532KT.H.

Interrupts are enabled upon entry to the task trap handler. Note that the SR register copy in the register array reflects the state of the status register after the exception occurred.

A pointer to the M68000 fault frame is provided as parameter faultfp. This pointer is the M68000 stack pointer (SP) after the fault has occurred. Fault frame members can be referenced as described in Chapter 3.1.

The register values in structure regs can be examined and, in rare circumstances, modified. If necessary, the fault frame at *faultfp can be modified, with extreme care, to force resumption at some other location in the task code. If the task trap handler returns to AMX, execution will resume at the location determined by the fault frame at *faultfp with registers set according to the values in the structure referenced by regp. Note that the SR register will be restored according to the value returned in the fault frame referenced by faultfp.

Since the task trap handler executes in the context of the task in which the exception occurred, it is free to use all AMX services normally available to tasks. In particular, the handler can call cjtkend to end task execution if so desired.

AMX 68000 Target Guide KADAK 9

Page 16 of the AMX Software (Target Guide) user manual — 2.2 Task Scheduling Hooks
Page 16 · click to enlarge
Page 16

2.2 Task Scheduling Hooks

There are four critical points within the AMX Task Scheduler. These critical points occur when:

a task is started a task ends a task is suspended a task is allowed to resume.

AMX allows a unique application procedure to be provided for each of these critical points. Pointers to your procedures are installed with a call to procedure cjkshook. You must provide a separate procedure for each of the four critical points. Since these procedures execute as part of the AMX Task Scheduler, their operation is critical. These procedures must be coded in assembler using techniques designed to ensure that they execute as fast as possible.

The AMX Task Scheduler calls each of your procedures with the same calling conventions.

Upon entry to your scheduling procedures, the following conditions exist:

Interrupts are disabled and must remain so. The Task Control Block address is in register A1. The stack pointer in register SP references the task's stack. The return address is on the stack at (SP). Registers D0, D1, A0, A1, A2 and A3 are free for use. Condition code flags in the status register (SR) can be altered. All other registers must be preserved.

Your procedures receive a pointer to the Task Control Block (TCB) of the task which is being started, ended, suspended or resumed. If you include AMX header file CJ532K.DEF in your assembly language module, you can reference the private region within the TCB reserved for your use as XTCBUSER(A1).

Your procedures are free to temporarily use the task's stack.

10 KADAK AMX 68000 Target Guide

Page 17 of the AMX Software (Target Guide) user manual — Device Interrupt Service
Page 17 · click to enlarge
Page 17

3. The Processor Interrupt System

3.1 Operation

The M68000 classifies all internal and external sources of interruption as exceptions. The processor automatically determines the cause of the exception and then branches indirectly through entries in the processor Exception Vector Table to an appropriate exception specific procedure.

The particular procedures which service internal or external device interrupt requests are called Interrupt Service Procedures. All other procedures are referred to as exception service procedures.

Upon entry to any Interrupt Service Procedure or exception service procedure the processor state is determined by the particular exception.

Device Interrupt Service

A subset of the exception vectors are reserved for the control of devices external to, or embedded in, the processor. These vectors include:

Vector 15 Uninitialized interrupt vector Vector 24 Spurious interrupt Vectors 25 Interrupt priority level 1 (lowest) to Vector 30 Interrupt priority level 6 (highest) Vector 31 Interrupt priority level 7 (Non-Maskable) Vectors 64 User assignable interrupts to 255

The external interrupt facility is enabled by setting the interrupt mask in the processor status register (SR) to 0 thereby enabling interrupts from priority levels 1 to 6. Note that interrupt priority level 7 cannot be inhibited.

The external interrupt facility is disabled by setting the interrupt mask in the processor status register (SR) to 6 thereby inhibiting interrupts from priority levels 1 to 6 inclusive. AMX never sets the processor interrupt mask to 7.

When an interrupt occurs at priority level n, the processor pushes zero or more words of processor dependent information on the current stack. The return address (current Program Counter) and the content of the processor status register are then pushed onto the current stack. The processor interrupt mask is set to n thereby disabling all external interrupts of priority less than or equal to n.

The interrupting device then identifies the interrupt source. In most cases, the device lets the processor use the interrupt priority level n vector. However, devices can be designed to present the processor with their own vector number. Any vector number in the range 0 to 255 is possible, but vectors 64 to 255 are reserved for this purpose. Programmable devices which have not been programmed with their particular vector number usually respond with vector number 15 signifying an uninitialized interrupt. If no device responds to the processor's demand for interrupt acknowledgment, the processor uses the spurious interrupt vector number 24.

AMX 68000 Target Guide KADAK 11

Page 18 of the AMX Software (Target Guide) user manual — Default Exception Service Procedures
Page 18 · click to enlarge
Page 18

Default Exception Service Procedures

AMX provides default service procedures for most exceptions. The zero divide, bounds check and overflow exceptions are serviced by AMX using its Task Trap Handler mechanism. All other exceptions handled by AMX are treated as fatal. AMX calls a Fatal Exception Procedure cjksfatalexh in module CJ532UF.C identifying the exception and the machine state at the time of the exception. If the Fatal Exception Procedure returns, AMX calls the Fatal Exit Procedure cjksfatal in the same module with one of the following fatal exit codes:

CJ_FETRAP Fatal exception trap CJ_FEISPTRAP Task exception trap in ISP CJ_FETKTRAP Task exception trap occurred:

in a Restart Procedure or in a Timer Procedure or in a task with no task trap handler

The Fatal Exception Procedure is written in C as follows. Prior to entry, interrupts are in the state determined by the particular exception.

#include "CJZZZ.H" /* AMX Headers */

void CJ_CCPP cjksfatalexh( struct cjxregs *regp, /* A(Register structure) */ int vnum, /* Vector number */ void *faultfp) /* A(Fault frame) */ {

: Process the error : }

The state of each register at the time of the fault is stored on the stack in an AMX register structure cjxregs. Parameter regp is a pointer to that structure. Structure cjxregs is defined in AMX header file CJ532KT.H.

A pointer to the M68000 fault frame is provided as parameter faultfp. This pointer is the M68000 stack pointer (SP) after the fault has occurred. Fault frame members can be referenced as follows:

*((CJ_T16U *)faultfp) is the SR saved in the fault frame *((CJ_T32U *)((CJ_T16U *)faultfp + 1)) is the A(fault instruction) *((CJ_T16U *)faultfp + 3) is the frame format type and vector offset

12 KADAK AMX 68000 Target Guide

Page 19 of the AMX Software (Target Guide) user manual — Processor Exceptions
Page 19 · click to enlarge
Page 19

3.2 AMX Vector Table

The M68000 processor provides an Exception Vector Table, often referred to as the AMX Vector Table, through which device interrupts are vectored and processor faults are trapped. The position of entries in the table and the vector numbers used to reference them are dictated by Motorola.

AMX provides a set of cjksixxxx service procedures to allow you to dynamically access or modify entries in the AMX Vector Table. The Motorola vector numbers must be used in all calls to these procedures to identify entries in the table.

Device Interrupts

AMX uses the AMX Vector Table to maintain pointers to Interrupt Service Procedures for all of the device interrupts to which the processor will respond. AMX does not provide a default Interrupt Service Procedure for every device interrupt. However, AMX does provide a default exception service procedure for the spurious interrupt (vector number 24) and the uninitialized interrupt (vector number 15).

Processor Exceptions

AMX maintains entries in the AMX Vector Table for all of the processor exceptions for which AMX assumes responsibility. These entries in the Vector Table are identified by Motorola's exception vector numbers which are defined in AMX header file CJ532KT.H. Figure 3.2-1 summarizes the exception vector mnemonics.

A 32-bit mask in your Target Parameter File is used to specify which of the possible exceptions you wish AMX to service. The mask bits are defined in Figure 3.2-1. The AMX Configuration Builder (see Chapter 4) puts a directive in your Target Parameter File to specify the mask required to meet your configuration requirements.

If an enable mask bit is not defined in Figure 3.2-1 for a particular exception, then AMX will not provide a default exception service procedure for that exception. For example, AMX does not provide service for the TRAP n vectors (vector numbers 32 to 47). Hence, all software traps are available for use by your application.

AMX does not provide default exception service procedures for any of the entries which Motorola has declared as undefined but reserved.

AMX 68000 Target Guide KADAK 13

Page 20 of the AMX Software (Target Guide) user manual — Vector Vector Enable Name Number Mask Exception
Page 20 · click to enlarge
Page 20

Vector Vector Enable Name Number Mask Exception

CJ_PRVNRES 0, 1 Reset CJ_PRVNBE 2 $00000004 Bus error (access fault) CJ_PRVNAE 3 $00000008 Address error CJ_PRVNII 4 $00000010 Illegal instruction CJ_PRVNZD 5 $00000020 Zero divide CJ_PRVNCH 6 $00000040 CHK instruction trap CJ_PRVNTV 7 $00000080 TRAPV instruction trap CJ_PRVNPV 8 $00000100 Privilege violation CJ_PRVNTR 9 $00000200 Trace CJ_PRVNLA 10 $00000400 Line 1010 (A) emulator CJ_PRVNLF 11 $00000800 Line 1111 (F) emulator 12 reserved CJ_PRVNCP 13 $00002000 Coprocessor protocol violation CJ_PRVNFE 14 $00004000 Format error (>= 68010) CJ_PRVNUI 15 $00008000 Uninitialized interrupt

16 to 23 reserved CJ_PRVNSI 24 $00000002 Spurious interrupt 25 to 31 Level 1 to 7 interrupt autovectors

CJ_PRVNTT 32 to 47 TRAP 0 to 15 Table

CJ_PRVNFPBS 48 $01000000 FP Branch or set on unordered condition CJ_PRVNFPIN 49 $02000000 FP Inexact result CJ_PRVNFPDZ 50 $04000000 FP Divide by zero CJ_PRVNFPUN 51 $08000000 FP Underflow CJ_PRVNFPOP 52 $10000000 FP Operand Error CJ_PRVNFPOV 53 $20000000 FP Overflow CJ_PRVNFPSN 54 $40000000 FP Signalling NAN CJ_PRVNFPUD 55 $80000000 FP Unimplemented data type

CJ_PRVNMMCF 56 MMU Configuration error CJ_PRVNMMOP 57 MMU Illegal operation CJ_PRVNMMAV 58 MMU Access level violation

59 to 63 reserved 64 to 255 User defined

Figure 3.2-1 AMX Vector Table and Vector Numbers

14 KADAK AMX 68000 Target Guide

Page 21 of the AMX Software (Target Guide) user manual — Non-Maskable Interrupt
Page 21 · click to enlarge
Page 21

3.3 AMX Interrupt Priority and NMI

The M68000 family of processors offers inherent interrupt priority ordering. The AMX Interrupt Supervisor supports this feature and allows the nesting of interrupts for fast response to high priority events.

The M68000 interrupt priority mask in the status (SR) register establishes the current interrupt priority. Tasks run at interrupt priority level 0 with all interrupt sources enabled. Some interrupts may be specifically disabled by an external interrupt controller.

Tasks must NOT alter the interrupt priority level to any level other than 0 (enabled) or 6 (disabled). Doing so will interfere with the interrupt nesting support provided by AMX.

Interrupt Service Procedures run at the interrupt priority level dictated by the interrupt source. An ISP must NOT set the interrupt priority level to any level numerically lower than the level of the interrupt which it is servicing.

Non-Maskable Interrupt

The Motorola M68000 processor provides a non-maskable priority level 7 interrupt (NMI). This interrupt cannot be inhibited by software. The processor will respond to any transition from interrupt request levels 0 to 6 to level 7 by generating a non-maskable interrupt. When the non-maskable interrupt occurs, the processor automatically saves zero or more processor dependent parameters, the return address and the processor status register on the current stack. The processor then vectors to a memory address determined by the level 7 interrupt autovector (vector number 31) in the Exception Vector Table.

You have complete control over the non-maskable interrupt ISP. Usually, the NMI interrupt is used to signal a catastrophic event such as a pending loss of power. The NMI ISP must not use any AMX services. The ISP must process the interrupt in an application-dependent fashion, restore all registers and return to the point of interruption if feasible. This ISP must assure that the interrupt facility is restored according to its state at the time the non-maskable interrupt occurred.

Because the occurrence of an NMI interrupt cannot be controlled, the NMI interrupt can occur at any instant, including within critical sections of AMX.

Consequently, the NMI ISP cannot use AMX service procedures for task communication.

AMX 68000 Target Guide KADAK 15

Page 22 of the AMX Software (Target Guide) user manual — 3.4 Conforming ISPs
Page 22 · click to enlarge
Page 22

3.4 Conforming ISPs

A conforming ISP consists of an ISP root and a device Interrupt Handler. The ISP root is created in your Target Configuration Module by the AMX Configuration Generator using the information provided in your Target Parameter File (see Chapter 4).

The address of the ISP root must be installed in the AMX Vector Table. You must provide a Restart Procedure or task which calls AMX procedure cjksivtwr or cjksivtx to install the ISP root pointer into the AMX Vector Table prior to enabling interrupt generation by the device.

The ISP root is the actual Interrupt Service Procedure which is executed by the processor when the interrupt occurs. The ISP root calls the AMX Interrupt Supervisor to indicate that interrupt service has begun.

The ISP root then calls the device Interrupt Handler to dismiss the interrupt request and service the device. Upon return from the Interrupt Handler, the ISP root informs the Interrupt Supervisor that the interrupt service is complete. The Interrupt Supervisor either resumes execution at the point of interruption or invokes the Task Scheduler to suspend the interrupted task in preparation for a context switch. The path taken is determined by the actions initiated by your Interrupt Handler.

Interrupt Handlers can be written as C procedures with or without a single 32-bit formal parameter. The parameter, if needed, is identified in your definition of the ISP root in your Target Parameter File (see Chapter 4.3).

Upon entry to your Interrupt Handler written in C, the following conditions exist:

Interrupts are enabled at priority n (0 to 6) where n is the priority at which the interrupt occurred. The stack pointer in register SP references the AMX Interrupt Stack.

The Interrupt Handler can also be written in assembly language. Use assembly language if speed of execution is critical. Upon entry to an Interrupt Handler written in assembly language, the following conditions exist:

Your Interrupt Handler parameter is in register D1. The stack pointer in register SP references the AMX Interrupt Stack. The return address is on the stack at (SP). Registers D0, D1, A0 and A1 are free for use. Condition code flags in the status register (SR) can be altered. All other registers must be preserved.

16 rev7 KADAK AMX 68000 Target Guide

Page 23 of the AMX Software (Target Guide) user manual — 3.4 Conforming ISPs
Page 23 · click to enlarge
Page 23

The following examples illustrate how simple an Interrupt Handler can be.

/* The ISP root definition in the Target Parameter File is as follows:*/ /* ...ISPC deviceisp,deviceih,26,0,0 */ /* The ISP root is given the public name deviceisp */ /* The Interrupt Handler is named deviceih */ /* The device interrupts on vector number 26 (level 2) */

void CJ_CCPP deviceih(void) {

local variables, if requiredClear the source of the interrupt request. Perform all device service. : }

/* Assume dcbinfo is some application device control block structure. */ /* Assume deviceXdcb is a structure variable defined as */ /* "struct dcbinfo deviceXdcb;". */ /* */ /* The ISP root definition in the Target Parameter File is as follows:*/ /* ...ISPC dcb_isp,dcb_ih,30,deviceXdcb,1 */ /* The ISP root is given the public name dcb_isp */ /* The Interrupt Handler is named dcb_ih */ /* The device interrupts on vector number 30 (level 6) */ /* deviceXdcb is the name of the public structure variable which */ /* contains information about the specific device. */

void CJ_CCPP dcb_ih(struct dcbinfo *dcbp) {

local variables, if required : Use device control block pointer dcbp to access structure variable deviceXdcb to determine device addresses. Clear the source of the interrupt request. Perform all device service. : }

AMX 68000 Target Guide KADAK 17

Page 24 of the AMX Software (Target Guide) user manual — 3.5 Nonconforming ISPs
Page 24 · click to enlarge
Page 24

3.5 Nonconforming ISPs

The M68000 family of processors provides an interrupt priority ordering mechanism which permits the use of nonconforming ISPs within an AMX system. Since nonconforming ISPs bypass the AMX Interrupt Supervisor, they cannot make use of any AMX services.

Nonconforming ISPs run at the interrupt priority level dictated by the interrupt source. A nonconforming ISP must NOT set the interrupt priority level to any level numerically lower than the level of the interrupt which it is servicing. Higher priority interrupts are only allowed if the corresponding ISPs are also nonconforming ISPs.

A nonconforming ISP must NOT allow an interrupt from ANY higher priority conforming ISP. Remember that, in this context, the ISP for the device which generates the AMX clock interrupt is considered to be a conforming ISP.

Upon entry to a nonconforming ISP the processor state matches its state at the time of the interrupt. The processor is in supervisor mode with interrupts disabled at priority level n (0 to 6) in the status register. No registers are free for use. All registers must be preserved.

The nonconforming ISP executes on the stack in effect at the time of the interrupt. Hence, the nonconforming ISP may execute on any task stack including the AMX Kernel Task's stack. A nonconforming ISP will execute on the AMX Interrupt Stack if the nonconforming ISP interrupts a conforming ISP.

The nonconforming ISP must service the device to remove the interrupt request and dismiss the interrupt with an RTE instruction.

18 KADAK AMX 68000 Target Guide

Page 25 of the AMX Software (Target Guide) user manual — 3.6 Processor Vector Initialization
Page 25 · click to enlarge
Page 25

3.6 Processor Vector Initialization

Whenever an internal or external device interrupt occurs, the M68000 processor unconditionally vectors to a unique memory address determined by an entry in the processor Exception Vector Table. The code located at that address is called an Interrupt Service Procedure.

Whenever an exception occurs, the M68000 processor also unconditionally vectors to a unique memory address determined by an entry in the processor Exception Vector Table. The code located at that address is called an exception handler.

Your Target Parameter File defines whether the Exception Vector Table is in ROM or RAM. The Target Parameter File further qualifies whether or not AMX is allowed to modify the table if it is in RAM.

If the table is declared to be alterable, AMX will allow you to dynamically install pointers to ISPs and exception handlers into the Exception Vector Table.

If the Exception Vector Table is in RAM and the table is declared to be alterable, AMX will install pointers to the AMX Exception Supervisor into selected exception vectors in the Exception Vector Table.

If the Exception Vector Table is unalterable (in ROM or simply constant by design), then it is your responsibility to initialize the vector table to meet your requirements. The address of a unique AMX exception handler must be installed in each entry in the Exception Vector Table for which AMX is to be responsible.

Each AMX exception handler is located at an offset from entry point cj_kdevt in your Target Configuration Module. Each offset is a multiple of 8 bytes. The AMX exception mask identifies the specific exceptions which AMX must handle. An exception is supported if its mask bit (see Figure 3.2-1) is enabled in the AMX exception mask. The AMX exception handler for the exception identified by mask bit j is located at byte address cj_kdevt+(i*8) where i is one less than the sum of the enabled bits in the AMX exception mask, counted from bit 0 to bit j inclusive.

For example, if vectors 2 (bus error) through 8 (privilege violation) inclusive are the only vectors to be serviced by AMX, the AMX exception mask will have value 0x000001FC. The AMX bus error exception handler will be found at entry point cj_kdevt (enable mask is 0x0004, j is 2, the bit sum is 1 and i is therefore 0). The AMX privilege violation exception handler will be found at entry point cj_kdevt+(6*8) (enable mask is 0x0100, j is 8, the bit sum is 7 and i is therefore 6).

You must also initialize entries in the Exception Vector Table for each interrupt which your application can generate. For each interrupting device, you must install the address of the device's Interrupt Service Procedure (ISP) into the device's entry in the vector table. For each conforming ISP or clock ISP, the address is the pointer to the ISP root named in your AMX Target Configuration Module. For prebuilt AMX clock drivers, you can determine the ISP root name by examining the call to cjksivtx() in procedure chclockinit() in the clock driver source module.

AMX 68000 Target Guide KADAK rev7 19

Page 26 of the AMX Software (Target Guide) user manual — 3.6 Processor Vector Initialization
Page 26 · click to enlarge
Page 26

This page left blank intentionally.

20 KADAK AMX 68000 Target Guide

Page 27 of the AMX Software (Target Guide) user manual — Using the Builder
Page 27 · click to enlarge
Page 27

4. Target Configuration Module

4.1 The Target Configuration Process

Every AMX application must include a Target Configuration Module which defines the manner in which AMX is to be used in your target hardware environment. The information in this file is derived from parameters which you must provide in your Target Parameter File.

The Target Parameter File is a text file which is structured according to the specification presented in Appendix A. You create and edit this file using the AMX Configuration Builder following the general procedure outlined in Chapter 16 of the AMX User's Guide. If you have not already done so, you should review that chapter before proceeding.

Using the Builder

When AMX is installed on your hard disk, the AMX Configuration Manager for Windows utility program and its related files are stored in directory CFGBLDW in your AMX installation directory. To start the Configuration Manager, double click on its filename, CJ532CM.EXE. Alternatively, you can create a Windows shortcut to the manager's filename and then simply double click the shortcut's icon.

To create a new Target Parameter File, select New Target Parameter File from the File menu. The Configuration Manager will create a new, as yet unnamed, file using its default AMX target parameters. When you have finished defining or editing your target configuration, select Save As... from the File menu. The Configuration Manager will save your Target Parameter File in the location which you identify using the filename which you provide.

A good starting point is to copy one of the Sample Target Parameter Files CJSAMTCF.UP provided with AMX into file HDWCFG.UP. Choose the file for the evaluation board which most closely matches your hardware platform. Then edit the file to define the requirements of your target hardware.

To open an existing Target Parameter File such as HDWCFG.UP, select Open... from the File menu and enter the file's name and location or browse to find the file. When you have finished defining or editing your target configuration, select Save from the File menu. The Configuration Manager will rename your original Target Parameter File to be HDWCFG.BAK and create an updated version of the file called HDWCFG.UP.

To direct the Configuration Manager to use its Configuration Generator utility to produce an updated copy of your Target Configuration Module, say HDWCFG.ASM, select Generate... from the File menu. If necessary, the path to the template file required by the generator to create your Target Configuration Module can be defined using the Templates... command on the File menu.

The assembly language Target Configuration Module must be assembled as described in the toolset specific chapter of the AMX Tool Guide for inclusion in your AMX system. The assembler will generate error messages which exactly pin-point any inconsistencies in the parameters in your Target Parameter File.

AMX 68000 Target Guide KADAK 21

Page 28 of the AMX Software (Target Guide) user manual — Screen Layout
Page 28 · click to enlarge
Page 28

Screen Layout

Figure 4.1-1 illustrates the Configuration Manager's screen layout once you have begun to create or edit a Target Parameter File. The title bar identifies the Target Parameter File being created or edited. Below the title bar is the menu bar from which the operations you wish the Manager to perform can be selected. Below the menu bar is an optional Toolbar with buttons for many of the most frequently used menu commands.

At the bottom of the screen is the status bar. As you select menu items, a brief description of their purpose is displayed in the status bar. If the Configuration Manager encounters an error condition, it presents an error message on the status bar describing the problem and, in many cases, the recommended solution.

Along the left margin of the screen are a set of one or more selector icons. These icons identify the type of output files which the Manager's Configuration Generator will produce. The Target Configuration Module selector must be active to generate the Target Configuration Module.

The center of the screen is used as an interactive viewing window through which you can view and modify your target configuration parameters.

AMX Software (Target Guide) — Screen Layout diagram (page 28)
Fig. 1 · Screen Layout

Figure 4.1-1 Configuration Manager Screen Layout

22 KADAK AMX 68000 Target Guide

Page 29 of the AMX Software (Target Guide) user manual — Field Editing
Page 29 · click to enlarge
Page 29

Menus

All commands to the Configuration Manager are available as items on the menus present on the menu bar. The File menu provides the conventional New, Open, Save and Save As... commands for creating and editing your Target Parameter File. It also provides the Exit command.

When the Target Configuration Module selector icon is the currently active selector, the Generate... command on the File menu can be used to generate your Target Configuration Module. The path to the template file required by the generator to create this product can be defined using the Templates... command on the File menu.

The Edit menu provides the conventional Cut, Copy, Paste and Undo editing commands. It also includes an Undo Page command to restore the content of all fields on a property page to undo a series of unwanted edits to the page. The Toolbar is hidden or made visible using the View Toolbar command on the Edit menu.

The Help menu provides access to the complete AMX Configuration Manager reference manual. Context sensitive help is also available by pressing the F1 function key or clicking the ? button on the Toolbar.

Field Editing

When the Target Configuration Module selector icon is the currently active selector, the Target Configuration Module's tabbed property sheet is displayed in the central region of the screen. Each tab provides access to a particular property page through which your target configuration parameters can be declared. For instance, if you select the ISP tab, the Configuration Manager will present an ISP definition window (property page) containing all of the parameters you must provide to completely define an Interrupt Service Procedure.

Some fields are boolean options in which all you can do is turn the option on or off by checking or unchecking the associated check box.

Some fields are option fields in which you must select one of a set of options identified with radio buttons. Click on the option button which meets your preference.

Other fields may require numeric or text entry. Parameters are entered or edited in these fields by typing new values or text to replace the current field content. Only displayable characters can be entered. New characters which you enter are inserted at the current cursor position in the field. Right and left arrow, backspace and delete keys may be used to edit the field.

When you are altering a numeric or text field, you tell the Configuration Manager that you are finished editing the field by striking the Enter key. At that point, the Configuration Manager checks the numeric value or text string that you have entered for correctness in the context of the current field. If the value or text string that you have entered is invalid, an error indication is provided on the status bar at the bottom of the screen suggesting how the fault should be corrected.

The Tab and Shift-Tab keys can also be used to complete the editing of a field and move to the next or previous field.

AMX 68000 Target Guide KADAK 23

Page 30 of the AMX Software (Target Guide) user manual — Add, Edit and Delete Objects
Page 30 · click to enlarge
Page 30

If you have modified some of the fields on a property page and then decide that these modified values are not correct, use the Undo Page command on the Edit menu or Toolbar to force the Configuration Manager to restore the content of all fields on the page to the values which were in effect when you moved to that property page.

When you go to save your Target Parameter File or prepare to move to another property page, the Configuration Manager will validate all parameters on the page which you are leaving. If any parameters are incomplete or inconsistent with each other, you will be forced to fix the problem before being allowed to proceed.

Add, Edit and Delete Objects

Separate property pages are provided to allow your definition of one or more objects such as ISPs or null functions. Pages of this type include a list box at the left side of the property page in which the currently defined objects are listed. At the bottom of the list box there may be a counter showing the number of objects in the list and the allowable maximum number of such objects.

Also below the list are two control buttons labeled Add and Delete. If the allowable maximum number of objects is 0 or if all such objects have already been defined, the Add button will be disabled. If there are no objects defined, the Delete button and all other fields on the page will be disabled.

To add a new object, click on the Add button. A new object with a default identifier will appear at the bottom of the list and will be opened ready for editing. When you enter a valid identifier for the object, your identifier will replace the default in the object list.

To edit an existing object's definition, double click on the object's identifier in the object list. The current values of all of that object's parameters will appear in the property page and the object will be opened ready for editing.

To delete an existing object, click on the object's identifier in the object list. Then click on the Delete button. Be careful because you cannot undo an object deletion.

The objects in the object list can be rearranged by dragging an object's identifier to the desired position in the list. You cannot drag an object directly to the end of the list. To do so, first drag the object to precede the last object on the list. Then drag the last object on the list to precede its predecessor on the list.

24 rev8 KADAK AMX 68000 Target Guide

Page 31 of the AMX Software (Target Guide) user manual — Enable Cache at Launch
Page 31 · click to enlarge
Page 31

4.2 Target Configuration Parameters

General Parameters

The General Parameter window allows you to define the general operating characteristics of your AMX system within your target hardware environment. The layout of the window is shown in Figure 4.1-1 in Chapter 4.1.

CPU Type

Identify your processor architecture by selecting a processor from the available list. This parameter is used to condition AMX to accommodate the operating characteristics of a particular processor or architecture. The supported list of processors includes but is not limited to:

68000, 68008, 68302, 68306, 68328, {68000 core} 68010, 68020, 68030, 68040, 68060, {68020 core} 68330, 68331, 68332, 68340, 68341, 68360, {CPU32 core} 5102 {68040 core}

AMX Launch

Most AMX applications are such that once AMX is launched the application runs forever. For such applications, check this box. If your AMX launch is to be temporary, uncheck this box. In this case, you will be able to shut down your AMX application and return to your main program from which AMX was launched.

Enable Cache at Launch

If the processor or architecture indicated by field CPU Type has cache control, then, before launching AMX, you must initialize the Memory Management Unit (MMU) to condition the memory subsystem to meet the caching requirements of your system.

When AMX is launched, if this box is checked, AMX will enable the processor instruction and data caches by calling the AMX cache support function cjcfhwbcache.

When AMX is launched, if this box is unchecked, AMX will not alter the state of the processor instruction or data caches.

If the processor or architecture indicated by field CPU Type has no cache control, leave this box unchecked.

AMX 68000 Target Guide KADAK 25

Page 32 of the AMX Software (Target Guide) user manual — Vector Table Location
Page 32 · click to enlarge
Page 32

Vectors in RAM

In most cases, the processor Exception Vector Table will be located in alterable RAM at address 0 or at some alternate address provided by you. Therefore check this box.

If your processor Exception Vector Table is in ROM, leave this box unchecked. In this case, you must initialize the ROM vector table for AMX use as directed in Chapter 3.6.

Vectors Not Alterable

Even if the processor Exception Vector Table will be located in RAM, you can still prevent AMX from altering it. To do so, check this box. In this case, be sure to initialize the vectors for AMX use as directed in Chapter 3.6.

Vector Table Location

For most M68000 processors, the Exception Vector Table is located in RAM at memory address 0. However, some processors include a Vector Base Register (VBR) which can be used to relocate the base of the Exception Vector Table elsewhere in memory.

If you wish AMX to derive the address of the Exception Vector Table, select derived from the pull down list. If your selected processor has a VBR, AMX will read the VBR at launch time to derive the address of the Exception Vector Table. If you are using a processor that does not have a VBR, AMX will assume that the Exception Vector Table is at address 0 as is appropriate for such processors.

If you wish AMX to set the address of the Exception Vector Table, select adjustable from the pull down list and enter the base address for the table. Specify the hexadecimal memory address of the alternate table. If your selected processor has a VBR, AMX will install the specified base address into the VBR at launch time, thereby establishing that address as the base address of the Exception Vector Table. If you are using a processor that does not have a VBR, AMX will ignore the base address parameter and assume that the Exception Vector Table is at address 0 as is appropriate for such processors.

In some cases, your Exception Vector Table may be in ROM with support for a shadow vector table in RAM. For example, assume that you use an MC68000 with ROM located at address 0. The processor does not have a Vector Base Register; it assumes that the Exception Vector Table is located at address 0. Now, assume that the ROM at address 0 includes a monitor which intercepts all interrupts and exceptions and dispatches each according to entries in a shadow vector table located at address $F0000. For such a case, select shadowed from the pull down list and enter the base address of the shadow vector table ($F0000 in this example). Specify the hexadecimal memory address of the shadow vector table. AMX will ignore the VBR, if one exists, and assume that the processor Exception Vector Table is at the specified base address.

26 KADAK AMX 68000 Target Guide

Page 33 of the AMX Software (Target Guide) user manual — Software I/O Delay
Page 33 · click to enlarge
Page 33

Software I/O Delay

AMX provides a device I/O delay procedure cjcfhwdelay which is used by AMX board support modules and sample device drivers to provide the necessary delay between sequential references to a device I/O port. Such delay is often required to accommodate long device access times when operating at very high processor clock frequencies.

Check this box to adjust the AMX software delay loop to match your hardware requirements. Enter your best estimate of the processor's effective instruction execution frequency. AMX will use this parameter to derive the loop count needed to provide a one microsecond delay.

For example, if your processor executes at 40 MHz with no wait states for instruction fetches and one clock cycle per instruction, enter a CPU clock frequency of 40 MHz.

If you are able to detect the processor frequency at run time, then you can dynamically adjust this I/O delay procedure to match your target hardware without reconfiguring your AMX application. To do so, enter a CPU frequency of 0 MHz. In this case, your main() program must install the processor frequency value into long variable cjcfhwdelayf prior to launching AMX.

Leave this box unchecked if you want the I/O delay procedure cjcfhwdelay to produce no delay beyond that inherent in the procedure call and return.

AMX 68000 Target Guide KADAK 27

Page 34 of the AMX Software (Target Guide) user manual — Fatal Exceptions
Page 34 · click to enlarge
Page 34

Fatal Exceptions

The Target Configuration Module defines the processor exceptions which are to be serviced by AMX and treated as fatal. These exceptions are specified by you by checking the appropriate boxes in the Fatal Exception window. The layout of the window is shown below.

This example allows AMX to service the bus error, address error, privilege violation, format error, uninitialized interrupt and spurious interrupt exceptions as fatal exceptions. Note that the BOUNDS, CHK and TRAPV exceptions are also serviced by AMX in order to allow the use of Task Trap Handlers by your application tasks. If any of these exceptions occur outside a task or in a task with no Task Trap Handler, AMX will treat the exception as fatal.

This example leaves the illegal instruction, trace and line emulation exceptions free for use by a debugger. It also leaves the floating point exceptions free for use by a software emulation library.

AMX Software (Target Guide) — Fatal Exceptions diagram (page 34)
Fig. 2 · Fatal Exceptions

28 KADAK AMX 68000 Target Guide

Page 35 of the AMX Software (Target Guide) user manual — 4.3 Interrupt Service Procedure (ISP) Definitions
Page 35 · click to enlarge
Page 35

4.3 Interrupt Service Procedure (ISP) Definitions

Your Target Configuration Module must include a device ISP root for each conforming ISP which you intend to use in your application. The ISP roots are constructed for you by the AMX Configuration Builder from ISP descriptions which you enter in the ISP Definition window. The layout of the window is shown below.

To add an ISP definition, click on the Add button. A new ISP with a default ISP root name of ---New--- will appear at the bottom of the ISP list and will be opened ready for editing. When you enter a name for the ISP root, it will replace the default name in the ISP list.

To edit an existing ISP definition, click on the name of the ISP root in the ISP list. The ISP definition will appear in the property page and will be opened ready for editing.

To delete an existing ISP definition, click on the name of the ISP root in the ISP list. Then click on the Delete button. Be careful because you cannot undo an ISP deletion.

AMX Software (Target Guide) — 4.3 Interrupt Service Procedure (ISP) Definitions diagram (page 35)
Fig. 3 · 4.3 Interrupt Service Procedure (ISP) Definitions

AMX 68000 Target Guide KADAK 29

Page 36 of the AMX Software (Target Guide) user manual — Handler Language
Page 36 · click to enlarge
Page 36

ISP Type

At least one of your ISPs must service a clock interrupt which provides AMX with its fundamental clock tick at the frequency and resolution defined in your AMX System Configuration Module. To define your custom clock ISP, choose Clock Handler from the pull down list. An alternate fast clock ISP can be provided by choosing Fast Clock Handler as described in Chapter 4.4. Other AMX clock drivers can be selected from the list presented when you click the Prebuilt Clock ISPs... button.

All other application ISPs must be conforming AMX ISPs which you define by choosing AMX Compliant from the pull down list.

ISP Root

Edit the default name ---New--- to provide the name you wish to give to the ISP root. The ISP root name is used to identify ISPs in the ISP list.

The ISP root is a function created by the AMX Configuration Builder in your Target Configuration Module. The function entry point is declared with a public symbol defined with the name you provide. The name must be unique and must conform to the symbol naming conventions of your assembler.

Interrupt Handler

Enter the name of your device Interrupt Handler which will clear the device interrupt request and service the device. This is the name of the procedure which will be called from the ISP root by the AMX Interrupt Supervisor once the interrupt source has been identified and the machine state preserved according to the conditions which existed at the time of the interrupt. Your Interrupt Handler must be coded as described in Chapter 3.4.

If your Interrupt Handler is coded in C, you may have to add a leading or trailing underscore to the Interrupt Handler name which you enter in order to meet the C function naming conventions of your C compiler.

Handler Language

Your Interrupt Handler can be coded in C or assembly language. Identify the language in which your Interrupt Handler is written by picking C or Assembly from the pull down list.

30 KADAK AMX 68000 Target Guide

Page 37 of the AMX Software (Target Guide) user manual — Prebuilt Clock ISPs
Page 37 · click to enlarge
Page 37

Interrupt Handler Parameter

Your Interrupt Handler can be coded to receive a 32-bit parameter every time it is called. The Parameter Type field is a pull down list used to identify what kind of parameter, if any, your Interrupt Handler expects. If your Interrupt Handler has no need for a parameter, set the Parameter Type to (none).

If your Interrupt Handler expects a numeric parameter, set the Parameter Type to Value and enter the required unsigned, 32-bit hexadecimal numeric value into the Parameter field.

If your Interrupt Handler parameter must be a pointer to a variable or function, set the Parameter Type to Symbol and enter the name of the variable or function into the Parameter field. The parameter must be a text string giving the name of a public symbol (variable or function) defined in some module in your AMX application. The symbol's 32-bit value, as resolved by your linker, will be passed to your Interrupt Handler as its parameter.

Prebuilt Clock ISPs

Clock drivers are provided with AMX for several common programmable interval timers. In some cases, the AMX clock ISP can be prebuilt in your Target Configuration Module. To select one of these clocks, click on the Prebuilt Clock ISPs... button. In the dialog box which is presented, check the box for the particular clock driver which you wish to use. If you do not wish to use a prebuilt clock ISP, leave all boxes unchecked.

AMX 68000 Target Guide KADAK 31

Page 38 of the AMX Software (Target Guide) user manual — 4.4 Defining a Fast Clock ISP
Page 38 · click to enlarge
Page 38

4.4 Defining a Fast Clock ISP

At least one of your ISPs must service a clock interrupt which provides AMX with its fundamental clock tick at the frequency and resolution defined in your AMX System Configuration Module. For many applications, your clock ISP will just be a standard AMX conforming ISP defined in the ISP Definition window. It is distinguished from all other ISPs by picking Clock Handler as its ISP Type.

Rarely does the Interrupt Handler for your AMX clock ISP have to do anything except dismiss the clock interrupt request. This is frequently accomplished by simply writing a command to a device I/O port. For such clocks, the AMX Configuration Builder lets you create a fast clock ISP without having to write any code at all.

To create a fast clock ISP, go to the ISP Definition window, click on the Add button and select Fast Clock Handler as the ISP Type. Then fill in the description of the operating characteristics of your clock device. The layout of the window is shown below.

AMX Software (Target Guide) — 4.4 Defining a Fast Clock ISP diagram (page 38)
Fig. 4 · 4.4 Defining a Fast Clock ISP

32 KADAK AMX 68000 Target Guide

Page 39 of the AMX Software (Target Guide) user manual — Write Size
Page 39 · click to enlarge
Page 39

ISP Type

Your fast clock ISP is identified as such by selecting Fast Clock Handler from the pull down list.

ISP Root

Edit the default name ---New--- to provide the name you wish to give to your fast clock ISP root. The ISP root name is used to identify your fast clock ISP in the ISP list.

The ISP root is a function created by the AMX Configuration Builder in your Target Configuration Module. The function entry point is declared with a public symbol defined with the name you provide. The name must be unique and must conform to the symbol naming conventions of your assembler.

Clock Service

Your clock device will be serviced as follows:

Write Value #1 to the device port at memory Address #1. Delay for the number of µs defined as I/O Delay (µs). Write Value #2 to the device port at memory Address #2.

Address and Value

Each address parameter specifies the 32-bit, hexadecimal value of an absolute memory address which, when referenced as an n-bit value, is decoded by your target hardware as a reference to your clock device. Each value parameter is an n-bit, hexadecimal value which must be written to the device port specified by the associated address in order to dismiss the clock interrupt.

If your clock device only requires that one value be written to one device port, leave fields Address #2 and Value #2 blank (empty).

I/O Delay (µs)

Your target hardware may not operate correctly if two sequential device I/O references are issued at the processor's instruction execution speeds. If this is the case, you can force the fast clock ISP to inject a delay of n µs between the I/O device references by entering a non-zero value into this field.

If your clock device requires no delay or only requires that one value be written to one device port, leave the I/O Delay field blank (empty).

Write Size

From the pull down list, select the number of bits (8, 16 or 32) which must be written to the clock device. The least significant n bits of each value will be written to the device.

AMX 68000 Target Guide KADAK 33

Page 40 of the AMX Software (Target Guide) user manual — 4.5 Null Functions
Page 40 · click to enlarge
Page 40

4.5 Null Functions

Occasionally, while developing an AMX application, it can be very convenient to be able to create software functions to satisfy your program link requirements without having to create the final version of these functions. For example, if your AMX System Configuration Module references a Restart Procedure and a task procedure which do not yet exist, you will have to create them in order to successfully link your system.

Such functions are called null functions because they do nothing. Such functions can be specified by you in the Null Function window whose layout is shown below.

To add a null function, click on the Add button. A new function named ---New--- will appear at the bottom of the list of functions. Click on the name in the list and edit it to meet your needs.

To edit the name of a null function, double click on its name in the list and edit it to meet your needs.

To delete a null function, click on its name in the list and then click on the Delete button.

AMX Software (Target Guide) — 4.5 Null Functions diagram (page 40)
Fig. 5 · 4.5 Null Functions

34 KADAK AMX 68000 Target Guide

Page 41 of the AMX Software (Target Guide) user manual — 4.6 ROM Option Parameters
Page 41 · click to enlarge
Page 41

4.6 ROM Option Parameters

The AMX ROM Option allows the subset of AMX and its managers required by your application to be linked together without any application code to form a separate AMX ROM image. The resulting AMX ROM can be located anywhere in your memory configuration. Your AMX application is then linked with a ROM Access Module which provides access to AMX and its managers in the AMX ROM.

The AMX ROM Option Module defines the subset of AMX and its managers which you wish to commit to the AMX ROM. This module is assembled and linked with the AMX Library to create that ROM. The AMX ROM Option Link/Locate Specification File is used to link and locate the ROM image as described in the toolset dependent chapter of the AMX Tool Guide.

The AMX ROM Access Module provides your AMX application with access to the AMX ROM. This module is assembled and linked with your AMX application.

To access the ROM Option window, use the AMX Configuration Builder to open your Target Parameter File. From the selector list, pick the ROM Option Module selector making it the active selector. The layout of the window is shown below.

AMX Software (Target Guide) — 4.6 ROM Option Parameters diagram (page 41)
Fig. 6 · 4.6 ROM Option Parameters

AMX 68000 Target Guide KADAK 35

Page 42 of the AMX Software (Target Guide) user manual — Resident Managers
Page 42 · click to enlarge
Page 42

Enable ROM Option

By default, the ROM Option feature is disabled. Check this box to enable the feature. You can disable the feature by removing the check from the box.

ROM Address

You must define the absolute physical ROM address at which the AMX ROM image is to be located. This address is dictated by you according to your hardware requirements. Enter the address value as an unsigned 32-bit hexadecimal number. The ROM memory address must be long aligned.

RAM Address

You must define the absolute physical RAM address of a block of 32 bytes reserved for use by AMX. This address is dictated by you according to your hardware requirements. Enter the address value as an unsigned 32-bit hexadecimal number. The RAM memory address must be long aligned.

Resident Managers

Check the boxes which identify the AMX managers which you wish to commit to the AMX ROM. If you do not want a particular manager to be in the ROM, leave the corresponding box unchecked.

If your AMX ROM was created without a particular manager, then an AMX fatal exit will occur if your system attempts to access that manager.

36 KADAK AMX 68000 Target Guide

Page 43 of the AMX Software (Target Guide) user manual — Clock Startup
Page 43 · click to enlarge
Page 43

5. Clock Drivers

5.1 Clock Driver Operation

You must provide a clock driver as part of your AMX application so that AMX can provide timing services. AMX clock drivers are provided with AMX for the timer chips used on the boards with which AMX has been tested. These drivers are ready for use and can be installed as described in Chapter 5.3.

An AMX clock driver consists of three parts: an initialization procedure, a clock Interrupt Service Procedure (ISP) and an optional shutdown procedure.

Clock Startup

The clock initialization procedure must configure the real-time clock to operate at the frequency defined in your AMX System Configuration Module. It can then install the pointer to the clock ISP root into the AMX Vector Table and start the clock.

Care must be taken to ensure that clock interrupts do not occur until the clock is properly configured and the pointer to the clock ISP root is present in the AMX Vector Table.

Your AMX application will not have any AMX timing services until your clock initialization procedure, say clockinit, has been executed. The first opportunity for clockinit to execute occurs when AMX begins to execute your Restart Procedures. It is recommended that your clockinit procedure be inserted into your list of Restart Procedures at the point at which you wish the clock to be enabled during the launch.

Although it is not recommended, there is nothing to prohibit you from deferring the starting of your clock by having some application task call your clockinit procedure.

The clock drivers provided with AMX illustrate how to install and start several different real-time clocks. You should be able to pattern your clock initialization procedure after the chip support procedure chclockinit in one of the AMX clock driver source files CHxxxxT.C.

AMX 68000 Target Guide KADAK 37

Page 44 of the AMX Software (Target Guide) user manual — Clock Shutdown
Page 44 · click to enlarge
Page 44

Clock Interrupts

A real-time clock used with the M68000 processor will interrupt either on one of the interrupt autovectors or on a user defined vector. In either case, the processor will automatically dispatch through its Vector Table to your clock ISP.

The clock ISP consists of an ISP root and an Interrupt Handler. The processor dispatches to the ISP root in response to the clock interrupt request. The ISP root calls the clock Interrupt Handler to dismiss the clock interrupt request. Your clock ISP must be defined as a conforming ISP of type Clock Handler as described in Chapter 4.3.

In some cases you may be able to create a fast clock ISP which has an ISP root but no Interrupt Handler. In this case, it is the ISP root which dismisses the clock interrupt request. Such a clock ISP is defined to be a conforming ISP of type Fast Clock Handler as described in Chapter 4.4.

In other cases you may be able to pick one of the prebuilt AMX clock ISPs which has an ISP root but no Interrupt Handler. In this case, it is the ISP root which dismisses the clock interrupt request. Such a clock ISP is selected from the list which is accessed via the Prebuilt Clock ISPs... button.

It is the ISP root which informs AMX that a hardware clock tick has occurred. When you define your clock ISP, your definition of the ISP as a Clock Handler (or Fast Clock Handler) or your selection of a prebuilt clock ISP ensures that the ISP is recognized by AMX as the source of its fundamental clock tick operating at the frequency and resolution defined in your AMX System Configuration Module.

Clock Shutdown

The clock shutdown procedure stops the clock in preparation for an AMX shutdown following a temporary launch of AMX. If AMX is launched for permanent execution, there is no need for a clock shutdown procedure.

If you intend to launch AMX for temporary execution, insert your clock shutdown procedure, say clockexit, into your list of Exit Procedures at the point at which you wish the clock to be disabled during the shutdown. Usually that will require that clockexit be the last Exit Procedure in the list because, once you stop your clock, AMX timing services will no longer be available.

The clock drivers provided with AMX illustrate how to disable several different real-time clocks. You should be able to pattern your clock shutdown procedure after the chip support procedure chclockexit in one of the AMX clock driver source files CHxxxxT.C.

38 KADAK AMX 68000 Target Guide

Page 45 of the AMX Software (Target Guide) user manual — 5.2 Custom Clock Driver
Page 45 · click to enlarge
Page 45

5.2 Custom Clock Driver

The easiest way to create a custom clock driver is by example. Assume that the counter/timer which you intend to use for your AMX clock is characterized as follows:

The I/O base address of the clock is at 0xFFA00100. The clock interrupt is generated using vector number 25. The clock interrupt is dismissed by writing bit pattern 0x08 to the clock register at its base address plus 4.

The Interrupt Handler for an assembly language conforming clock ISP for such a device could be coded as follows:

XDEF _clockih _clockih EQU * * * receives D1 = ISP root parameter = A(clock base) * MOVEA.L D1,A0 * A0 = A(clock base) MOVE.B #$08,4(A0) * Dismiss interrupt RTS * Return

Create a clock ISP root for the clock as described in Chapter 4.3. Use the following parameters in your definition of the clock ISP.

ISP Type: Clock Handler ISP Root: clockroot Interrupt Handler: clockih Handler Language: Assembly Parameter Type: Value Parameter: 0xFFA00100

ISP Type: Fast Clock Handler ISP Root: clockroot Address #1: 0xFFA00104 Value #1: 0x08 I/O Delay: leave blank Address #2: leave blank Value #2: leave blank Write Size: 8-bit

AMX 68000 Target Guide KADAK 39

Page 46 of the AMX Software (Target Guide) user manual — 5.2 Custom Clock Driver
Page 46 · click to enlarge
Page 46

The clock initialization procedure for this custom clock driver could be coded in C as follows. Insert procedure clockinit into your list of Restart Procedures provided in your System Configuration Module at the point at which you wish the clock to be enabled during the launch.

void CJ_CCPP clockroot(void); /* External clock ISP root */

void CJ_CCPP clockinit(void) {

/* Inhibit clock interrupts */ /* Configure clock for correct frequency */

/* Install pointer to clock ISP root into AMX Vector Table */ cjksivtwr(25, (CJ_ISPPROC)clockroot);

/* Start clock and enable clock interrupts */ }

40 KADAK AMX 68000 Target Guide

Page 47 of the AMX Software (Target Guide) user manual — Porting the MC683xx TPU Clock Driver
Page 47 · click to enlarge
Page 47

5.3 AMX Clock Drivers

AMX clock drivers are provided with AMX for the timer chips used on the boards with which AMX has been tested. These drivers are ready for use as described in this chapter. The clock drivers are delivered in chip support source files having names of the form CHnnnnT.C where nnnn identifies the particular clock chip. The clock chip support procedures are named chxxxxxxx.

5.3.1 MC683xx TPU Clock Driver

The AMX clock driver for the Motorola MC683xx TPU is ready for use on either the Motorola M68332EVK Evaluation Kit or the GreenSpring Platform332 board. It is configured to use timer channel 0 operating at 1 KHz (1 ms period). Source code for this AMX clock driver is provided in file CH68332T.C.

You must compile clock source module CH68332T.C and link the resulting object module with the rest of your AMX application.

To use the AMX MC683xx TPU clock driver, you must create a clock ISP root as described in Chapter 4.3. Simply check the box next to the MC683xx TPU clock ISP on the list provided via the Prebuilt Clock ISPs... button.

Your Target Configuration Module will include a clock ISP root named _ch68tpuclk. The clock driver's initialization procedure will install the pointer to this clock ISP into the AMX Vector Table. On the Motorola M68332EVK board or GreenSpring Platform332 board, the pointer is installed into the entry for interrupt vector number 96+n ($60+n) where n is the TPU timer channel number (0 to 15).

Clock driver module CH68332T.C includes the clock initialization procedure chclockinit and the clock shutdown procedure chclockexit. Insert procedure chclockinit into the list of Restart Procedures provided in your System Configuration Module at the point at which you wish the clock to be enabled during the launch. If you intend to launch AMX for temporary execution, insert chclockexit into the list of Exit Procedures at the point at which you wish the clock to be disabled during the shutdown.

Porting the MC683xx TPU Clock Driver

If you wish to use a different MC683xx TPU timer channel, change the timer frequency or use a different AMX vector number, you must edit the definitions in source file CH68332T.C and recompile the module. Edit instructions are included in the file.

AMX 68000 Target Guide KADAK 41

Page 48 of the AMX Software (Target Guide) user manual — Porting the MC68360 PIT Clock Driver
Page 48 · click to enlarge
Page 48

5.3.2 MC68360 PIT Clock Driver

The AMX clock driver for the Motorola MC68360 Periodic Interval Timer (PIT) is ready for use on the Motorola M68360QUADS Application Development System board. It is configured to operate at approximately 1 KHz (1 ms period). Source code for this AMX clock driver is provided in file CH68360T.C.

You must compile clock source module CH68360T.C and link the resulting object module with the rest of your AMX application.

To use the AMX MC68360 PIT clock driver, you must create a clock ISP root as described in Chapter 4.3. Simply check the box next to the MC68360 PIT clock ISP on the list provided via the Prebuilt Clock ISPs... button.

Your Target Configuration Module will include a clock ISP root named _ch68360clk. The clock driver's initialization procedure will install the pointer to this clock ISP into the AMX Vector Table. On the Motorola M68360QUADS Application Development System board, the pointer is installed into the entry for interrupt vector number 96 ($60).

Clock driver module CH68360T.C includes the clock initialization procedure chclockinit and the clock shutdown procedure chclockexit. Insert procedure chclockinit into the list of Restart Procedures provided in your System Configuration Module at the point at which you wish the clock to be enabled during the launch. If you intend to launch AMX for temporary execution, insert chclockexit into the list of Exit Procedures at the point at which you wish the clock to be disabled during the shutdown.

Porting the MC68360 PIT Clock Driver

If you wish to change the MC68360 PIT timer frequency or use a different AMX vector number, you must edit the definitions in source file CH68360T.C and recompile the module. Edit instructions are included in the file.

42 KADAK AMX 68000 Target Guide

Page 49 of the AMX Software (Target Guide) user manual — Porting the MC68230 Clock Driver
Page 49 · click to enlarge
Page 49

5.3.3 MC68230 Clock Driver

The AMX clock driver for the Motorola MC68230 Parallel Interface/Timer is ready for use on the Motorola M68EC040 Integrated Development Platform (IDP). It is configured to operate at approximately 1 KHz (1 ms period). Source code for this AMX clock driver is provided in file CH68230T.C.

You must compile clock source module CH68230T.C and link the resulting object module with the rest of your AMX application.

To use the AMX MC68230 clock driver, you must create a clock ISP root as described in Chapter 4.3. Simply check the box next to the MC68230 clock ISP on the list provided via the Prebuilt Clock ISPs... button.

Your Target Configuration Module will include a clock ISP root named _ch68230clk. The clock driver's initialization procedure will install the pointer to this clock ISP into the AMX Vector Table. On the Motorola M68EC040 Integrated Development Platform (IDP), the pointer is installed into the entry for interrupt vector number 96 ($60).

Clock driver module CH68230T.C includes the clock initialization procedure chclockinit and the clock shutdown procedure chclockexit. Insert procedure chclockinit into the list of Restart Procedures provided in your System Configuration Module at the point at which you wish the clock to be enabled during the launch. If you intend to launch AMX for temporary execution, insert chclockexit into the list of Exit Procedures at the point at which you wish the clock to be disabled during the shutdown.

Porting the MC68230 Clock Driver

If you wish to change the MC68230 timer frequency or use a different AMX vector number, you must edit the definitions in source file CH68230T.C and recompile the module. Edit instructions are included in the file.

AMX 68000 Target Guide KADAK 43

Page 50 of the AMX Software (Target Guide) user manual — Porting the MC68901 Clock Driver
Page 50 · click to enlarge
Page 50

5.3.4 MC68901 Clock Driver

The AMX clock driver for the Motorola MC68901 Multi-Function Peripheral is ready for use on the Motorola MVME133 VMEmodule board. It is configured to use timer A operating at 1 KHz (1 ms period). Source code for this AMX clock driver is provided in file CH68901T.C.

You must compile clock source module CH68901T.C and link the resulting object module with the rest of your AMX application.

To use the AMX MC68901 clock driver, you must create a clock ISP root as described in Chapter 4.3. Simply check the box next to the MC68901 clock ISP on the list provided via the Prebuilt Clock ISPs... button.

Your Target Configuration Module will include a clock ISP root named _ch68901clk. The clock driver's initialization procedure will install the pointer to this clock ISP into the AMX Vector Table. On the Motorola MVME133 VMEmodule board, the pointer is installed into the entry for interrupt vector number 96+n ($60+n) where n is $0D for timer A (or 8 for timer B, 5 for timer C or 4 for timer D).

Clock driver module CH68901T.C includes the clock initialization procedure chclockinit and the clock shutdown procedure chclockexit. Insert procedure chclockinit into the list of Restart Procedures provided in your System Configuration Module at the point at which you wish the clock to be enabled during the launch. If you intend to launch AMX for temporary execution, insert chclockexit into the list of Exit Procedures at the point at which you wish the clock to be disabled during the shutdown.

Porting the MC68901 Clock Driver

If you wish to use a different MC68901 timer, say B (or C or D), or change the timer frequency or use a different AMX vector number, you must edit the definitions in source file CH68901T.C and recompile the module. Edit instructions are included in the file.

44 KADAK AMX 68000 Target Guide

Page 51 of the AMX Software (Target Guide) user manual — Appendix A. Target Parameter File Specification
Page 51 · click to enlarge
Page 51

Appendix A. Target Parameter File Specification

A.1 Target Parameter File Structure

The Target Parameter File is a text file structured as illustrated in Figure A.1-1. This file can be created and edited by the AMX Configuration Manager, a Windows® utility provided with AMX.

; AMX Target Parameter File : ...LAUNCH PERM,VNA ...HDW PROC,VMASK,VBR,EVTROM,CACHE ...VBASE VTABLE ...DELAY CPUFREQ ; ; Null Functions (optional; one line for each null function) ...NULLFN FNNAME ; ; Conforming ISP definitions (one line for each ISP) ...ISPA ISPROOT,HANDLER,VNUM,PARAM,PARTYPE ...ISPC ISPROOT,HANDLER,VNUM,PARAM,PARTYPE ; ; Conforming fast clock ISP (no user code required) ...CLKFAST CLKROOT,CLKADR,CLKCMD,CLKADR2,CLKCMD2,IODELAY,VNUM ...CLKFAST16 CLKROOT,CLKADR,CLKCMD,CLKADR2,CLKCMD2,IODELAY,VNUM ...CLKFAST32 CLKROOT,CLKADR,CLKCMD,CLKADR2,CLKCMD2,IODELAY,VNUM ; or Motorola MC683xx TPU prebuilt clock ISP ...CLK68TPU ; or Motorola MC68360 PIT prebuilt clock ISP ...CLK68360 ; or Motorola MC68230 prebuilt clock ISP ...CLK68230 ; or Motorola MC68901 prebuilt clock ISP ...CLK68901 ; or conforming clock ISP (coded in assembly language) ...CLKA CLKROOT,CLKHAND,VNUM,PARAM,PARTYPE ; or conforming clock ISP (coded in C) ...CLKC CLKROOT,CLKHAND,VNUM,PARAM,PARTYPE ; ; AMX ROM Option (optional) ...ROMOPT ROMADR,RAMADR ...ROMSM ;Semaphore Manager ...ROMEM ;Event Manager ...ROMMB ;Mailbox Manager ...ROMMX ;Message Exchange Manager ...ROMBM ;Buffer Manager ...ROMMM ;Memory Manager ...ROMCL ;Circular List Manager ...ROMLL ;Linked List Manager ...ROMTD ;Time/Date Manager

Figure A.1-1 AMX Target Parameter File

AMX 68000 Target Guide KADAK A-1

Page 52 of the AMX Software (Target Guide) user manual — Appendix A. Target Parameter File Specification
Page 52 · click to enlarge
Page 52

The Target Parameter File consists of a sequence of directives consisting of a keyword of the form ...XXX beginning in column one which is usually followed by a parameter list. Some directives require only a keyword with no parameters. Any line in the file which does not begin with a valid keyword is considered a comment and is ignored.

It is the purpose of this appendix to specify all AMX 68000 directives by defining their keywords and the parameters, if any, which they require.

The example in Figure A.1-1 uses symbolic names for all of the parameters following each of the keywords. The symbol names in the Target Parameter File are replaced by the actual parameters needed in your system.

The order of keywords in the Target Parameter File is not critical. The order of the keywords in Figure A.1-1 may not match their order in the sample Target Parameter File provided with AMX.

It is expected that you will use the AMX Configuration Manager to create and edit your Target Parameter File. The Configuration Manager creates the directives using the parameters which you provide. Since these parameters are well described in Chapter 4, the parameter definitions presented in this appendix will be limited to the detail needed to form a working specification.

If you are unable to use AMX Configuration Manager utility, you should refer to the porting directions provided in Appendix A.3.

A-2 KADAK AMX 68000 Target Guide

Page 53 of the AMX Software (Target Guide) user manual — ...HDW PROC,VMASK,VBR,EVTROM,CACHE
Page 53 · click to enlarge
Page 53

A.2 Target Parameter File Directives

The AMX Launch Parameters are defined as follows.

...LAUNCH PERM,VNA

PERM 0 if the AMX launch is temporary 1 if the AMX launch is permanent VNA 0 if the AMX Vector Table entries are to be alterable 1 if the AMX Vector Table entries are NOT to be alterable

You must set VNA to 0 to allow AMX or your application to dynamically install exception handlers into the AMX Vector Table at run time. If you set VNA to 0, you must also set EVTROM to 0 in the ...HDW keyword entry. If you set VNA to 1, you must initialize the AMX Vector Table entries for AMX use as described in Chapter 3.6.

The Target Parameter File includes a set of hardware definitions.

...HDW PROC,VMASK,VBR,EVTROM,CACHE

PROC Processor identifier VMASK = $MMMMMMMM = AMX exception vector mask VBR = $xxxxxxxx = A(Exception Vector Table) for VBR = -1 if VBR is read only EVTROM 0 if the AMX Vector Table is to be in RAM 1 if the AMX Vector Table is to be in ROM CACHE 0 if cache is to be ignored by AMX at launch 1 if cache is to be enabled by AMX at launch

The PROC parameter is a string used to identify the processor architecture. PROC must be one of:

68000, 68008, 68302, 68306, 68328, {68000 core} 68010, 68020, 68030, 68040, 68060, {68020 core} 68330, 68331, 68332, 68340, 68341, 68360, {CPU32 core} 5102 {68040 core}

Set bit N of the VMASK Exception Vector Mask for each of the exceptions which are to be serviced by AMX. For example, set this parameter to $FF00EFFE to allow AMX to handle all exceptions. Bits in the mask are defined in Figure 3.2-1. When you are using AMX with a debugger, do not set any of the mask bits for exceptions which the debugger services. For example, a mask of $000041EC is commonly used with many debuggers.

The CACHE parameter can be used to instruct AMX to enable the M68000 instruction and data caches when AMX is launched. If the processor or architecture selected with parameter PROC has no cache control, set parameter CACHE to 0.

AMX 68000 Target Guide KADAK rev6 A-3

Page 54 of the AMX Software (Target Guide) user manual — ...VBASE $F0000
Page 54 · click to enlarge
Page 54

Vector Base Register

The VBR parameter is used to specify the memory address at which the Exception Vector Table is located. For most applications, the Exception Vector Table is located at address 0. You can use the VBR parameter to redefine the location of the Exception Vector Table or to define its location in ROM.

At launch, AMX installs the address specified by parameter VBR into the processor's Vector Base Register (VBR), if one exists for the processor specified by parameter PROC. If parameter VBR is set to -1, AMX will leave the VBR unaltered and will read its content at launch time to determine the address of the Exception Vector Table.

If you are using a processor that does not have a VBR, set parameter VBR to 0. AMX will assume that the Exception Vector Table is at address 0 as is appropriate for such processors.

Shadow Vector Table Location

In some cases, your Exception Vector Table may be in ROM with support for a shadow vector table in RAM. For example, assume that you use an MC68000 with ROM located at address 0. The processor does not have a Vector Base Register; it assumes that the Exception Vector Table is located at address 0. Now, assume that the ROM at address 0 includes a monitor which intercepts all interrupts and exceptions and dispatches each according to entries in a shadow vector table located at address $F0000.

To use AMX in this example, the ...HDW parameter VBR must be set to 0 and the following directive must be present in the Target Parameter File.

...VBASE $F0000

AMX will assume that the Exception Vector Table is at address $F0000. If the processor has a Vector Base Register, AMX will ignore its content and leave it unaltered.

A-4 KADAK AMX 68000 Target Guide

Page 55 of the AMX Software (Target Guide) user manual — ...NULLFN FNNAME
Page 55 · click to enlarge
Page 55

Device I/O Delay

The Target Parameter File includes a device I/O delay definition.

...DELAY CPUFREQ

CPUFREQ M68000 processor instruction execution frequency (MHz)

The ...DELAY directive allows you to condition the delay loop of the AMX device I/O delay procedure cjcfhwdelay to match your hardware requirements. This directive allows AMX to use your estimate of the processor's instruction execution frequency defined by parameter CPUFREQ to derive the loop count needed to provide a one microsecond delay.

Null Function Declarations

To create a null function, a function that does nothing, include the following directive in your Target Parameter File.

...NULLFN FNNAME

FNNAME Name given to the null function

For every ...NULLFN directive, your Target Configuration Module will include a public assembly language function with name given by your parameter FNNAME. The function will do nothing but return to the caller.

AMX 68000 Target Guide KADAK A-5

Page 56 of the AMX Software (Target Guide) user manual — ...ISPC ISPROOT,HANDLER,VNUM,PARAM,PARTYPE ...ISPA ISPROOT,HANDLER,VNUM,PARAM,PARTYPE
Page 56 · click to enlarge
Page 56

Conforming ISP Declarations

The Target Parameter File must include a definition of an ISP root for each conforming Interrupt Service Procedure (ISP) which you intend to use in your application. The ISP root definition is provided using one of the following directives. The ISP root is declared using ...ISPC if its Interrupt Handler is coded in C or ...ISPA if its Interrupt Handler is coded in assembly language.

...ISPC ISPROOT,HANDLER,VNUM,PARAM,PARTYPE ...ISPA ISPROOT,HANDLER,VNUM,PARAM,PARTYPE

ISPROOT Name of the ISP root entry point HANDLER Name of the public device Interrupt Handler VNUM Interrupt vector number assigned to the device PARAM Interrupt Handler parameter PARTYPE Parameter PARAM type

If your Interrupt Handler does not require a parameter, leave field PARAM blank (empty) and set PARTYPE to 0.

If your Interrupt Handler requires a numeric parameter, set PARAM to the 32-bit signed or unsigned value and set PARTYPE to 0. The numeric value must be expressed in a form acceptable to your assembler.

If your Interrupt Handler requires a pointer to a public variable as a parameter, let PARAM be the name of that variable and set PARTYPE to 1.

VNUM defines the interrupt vector number which you have assigned to the device. VNUM is 25 to 31 or 64 to 255. Note that all other vector numbers in the range 0 to 255 are reserved by Motorola.

If VNUM is 0 to 255, AMX will automatically install the pointer to the ISP root ISPROOT into vector number VNUM in the AMX Vector Table when AMX is launched. The pointer will be installed by AMX before any application Restart Procedures execute. Consequently, you must ensure that interrupts from the device are not possible at the time AMX is launched.

If VNUM is -1, you must provide a Restart Procedure or task which installs the pointer to the ISP root ISPROOT into the AMX Vector Table using AMX procedure cjksivtwr or cjksivtx.

Parameter VNUM cannot be adjusted using the AMX Configuration Builder. This parameter is provided for compatibility with other AMX implementations.

A-6 KADAK AMX 68000 Target Guide

Page 57 of the AMX Software (Target Guide) user manual — AMX Clock Handler Declaration
Page 57 · click to enlarge
Page 57

AMX Clock Handler Declaration

The Target Parameter File must include a definition of an ISP root for your AMX clock handler. The clock ISP root definition must be provided using one of the following directives. The clock ISP root is declared using ...CLKC if its Interrupt Handler is coded in C or ...CLKA if its Interrupt Handler is coded in assembly language. The clock ISP root can be declared using ...CLKFAST if an Interrupt Handler is not required to service the clock.

...CLK68TPU Prebuilt Motorola MC683xx TPU Clock ISP ...CLK68360 Prebuilt Motorola MC68360 PIT Clock ISP ...CLK68230 Prebuilt Motorola MC68230 Clock ISP ...CLK68901 Prebuilt Motorola MC68901 Clock ISP ...CLKC CLKROOT,CLKHAND,VNUM,PARAM,PARTYPE ...CLKA CLKROOT,CLKHAND,VNUM,PARAM,PARTYPE ...CLKFAST CLKROOT,CLKADR,CLKCMD,CLKADR2,CLKCMD2,IODELAY,VNUM ...CLKFAST16 CLKROOT,CLKADR,CLKCMD,CLKADR2,CLKCMD2,IODELAY,VNUM ...CLKFAST32 CLKROOT,CLKADR,CLKCMD,CLKADR2,CLKCMD2,IODELAY,VNUM

CLKROOT Name of the clock ISP root entry point CLKHAND Name of the public clock device Interrupt Handler VNUM Interrupt vector number assigned to the clock device PARAM Interrupt Handler parameter PARTYPE Parameter PARAM type

If your clock Interrupt Handler does not require a parameter, leave field PARAM blank (empty) and set PARTYPE to 0.

If your clock Interrupt Handler requires a numeric parameter, set PARAM to the 32-bit signed or unsigned value and set PARTYPE to 0. The numeric value must be expressed in a form acceptable to your assembler.

If your clock Interrupt Handler requires a pointer to a public variable as a parameter, let PARAM be the name of that variable and set PARTYPE to 1.

The definition of parameter VNUM is exactly the same as that described for conforming ISPs declared using the ...ISPC or ...ISPA directives. However, unless warranted by exceptional circumstances, parameter VNUM should always be set to -1 in the declaration of your clock ISP root. It is the responsibility of your clock initialization procedure to install the pointer to the ISP root ISPROOT into the AMX Vector Table.

Parameter VNUM cannot be adjusted using the AMX Configuration Builder. This parameter is provided for compatibility with other AMX implementations.

AMX 68000 Target Guide KADAK A-7

Page 58 of the AMX Software (Target Guide) user manual — ...CLKFAST CLKROOT,CLKADR,CLKCMD,CLKADR2,CLKCMD2,IODELAY,VNUM
Page 58 · click to enlarge
Page 58

If your clock can be serviced by writing one or two n-bit values to a device I/O port, you can use the ...CLKFAST directive to create a very fast clock ISP root with no application code required. The general form of the ...CLKFAST directive is as follows.

...CLKFAST CLKROOT,CLKADR,CLKCMD,CLKADR2,CLKCMD2,IODELAY,VNUM

CLKROOT Name of the clock ISP root entry point CLKADR 32-bit numeric device memory address CLKCMD 8-bit numeric command CLKADR2 32-bit numeric secondary device memory address CLKCMD2 8-bit numeric secondary command IODELAY Delay (µs) required between I/O commands VNUM Interrupt vector number assigned to the clock device

The numeric parameters must be expressed in a form acceptable to your assembler. Parameters CLKADR2, CLKCMD2, IODELAY and VNUM can be omitted if they are not required. If a parameter is omitted, its field must be left blank (empty) and the comma to the left of the field must be retained. If the resulting ...CLKFAST directive ends with a string of commas because the intervening parameters have all been omitted, it is acceptable to delete the trailing commas.

The clock ISP root will dismiss the clock interrupt by writing the 8-bit value CLKCMD to the 32-bit device memory address CLKADR. If parameter CLKADR2 is present in the ...CLKFAST directive, the clock ISP root will then write the 8-bit value to the 32-bit device memory address CLKADR2. If parameter CLKADR2 is present, parameter CLKCMD2 must also be present. If this second device I/O command is not required, leave both CLKCMD2 and CLKADR2 blank (empty).

If two I/O commands are provided, parameter IODELAY can be used to define the delay, if any, required after the first command before the second command can be issued. The delay is provided by a call to AMX procedure cjcfhwdelay (see directive ...DELAY).

If there is no need for a delay or a second command is not required, leave the IODELAY field blank (empty).

Parameter VNUM has been described on the preceding page. If parameter VNUM is omitted, then a value of -1 is assumed for VNUM.

Use the ...CLKFAST16 directive if 16-bit values must be written to the clock. Use the ...CLKFAST32 directive if 32-bit values must be written to the clock.

A-8 KADAK AMX 68000 Target Guide

Page 59 of the AMX Software (Target Guide) user manual — AMX ROM Option
Page 59 · click to enlarge
Page 59

AMX ROM Option

To use the AMX ROM option, the Target Parameter File must include the following directives.

...ROMOPT ROMADR,RAMADR ...ROMSM ;Semaphore Manager ...ROMEM ;Event Manager ...ROMMB ;Mailbox Manager ...ROMMX ;Message Exchange Manager ...ROMBM ;Buffer Manager ...ROMMM ;Memory Manager ...ROMCL ;Circular List Manager ...ROMLL ;Linked List Manager ...ROMTD ;Time/Date Manager

Parameter ROMADR is the absolute physical ROM address at which the AMX ROM image is to be located.

Parameter RAMADR is the absolute physical RAM address of a block of 32 bytes reserved for use by AMX.

Both ROMADR and RAMADR must specify memory addresses which are long aligned.

Parameters ROMADR and RAMADR must be expressed as undecorated hexadecimal numbers. An undecorated hexadecimal number is a hexadecimal number expressed without the leading or trailing symbols used by programming languages to identify such numbers.

Language Hexadecimal Undecorated C 0xABCDEF01 ABCDEF01 Assembler (Intel) 0ABCDEF01H ABCDEF01 Assembler (Motorola) $ABCDEF01 ABCDEF01

Keywords ...ROMxx are used to identify the AMX managers which you wish to commit to the AMX ROM. If you do not want a particular manager to be in the ROM, omit the corresponding keyword statement from the Target Parameter File or insert the comment character ; in front of the keyword.

AMX 68000 Target Guide KADAK A-9

Page 60 of the AMX Software (Target Guide) user manual — A.2 Target Parameter File Directives
Page 60 · click to enlarge
Page 60

This page left blank intentionally.

A-10 KADAK AMX 68000 Target Guide

Page 61 of the AMX Software (Target Guide) user manual — CJ532CG HDWCFG.UP CJ532HDW.CT HDWCFG.ASM
Page 61 · click to enlarge
Page 61

A.3 Porting the Target Parameter File

It is expected that you will use the AMX Configuration Manager to create and edit your Target Parameter File. If you are unable to use the AMX Configuration Manager utility, you will have to create and edit your Target Parameter File using a text editor.

You should begin by choosing one of the sample Target Parameter Files provided with AMX. Choose the Target Parameter File for the Sample Program which operates on the evaluation board which most closely matches your target hardware. Edit the parameters in all directives to meet your requirements. Follow the specifications provided in Appendix A.2 and adhere to the detailed parameter definitions given in the presentation of the AMX Configuration Manager screens in Chapter 4.

The AMX Configuration Manager includes its own copy of the AMX Configuration Generator which it uses to produce your Target Configuration Module from the Target Configuration Template File and the directives in your Target Parameter File. If you are unable to use the Configuration Manager, you will have to use the stand alone version of the AMX Configuration Generator.

The command line required to run the Configuration Generator and use it to produce a Target Configuration Module HDWCFG.ASM from the AMX 68000 Target Configuration Template File CJ532HDW.CT and a Target Parameter File called HDWCFG.UP is as follows:

CJ532CG HDWCFG.UP CJ532HDW.CT HDWCFG.ASM

If you are not doing your development on a PC or compatible, you may still be able to port the Configuration Generator to your development system as described in Appendix C of the AMX User's Guide.

AMX 68000 Target Guide KADAK A-11

Page 62 of the AMX Software (Target Guide) user manual — A.3 Porting the Target Parameter File
Page 62 · click to enlarge
Page 62

This page left blank intentionally.

A-12 KADAK AMX 68000 Target Guide

Page 63 of the AMX Software (Target Guide) user manual — Processor and C Interface Procedures (class cf )
Page 63 · click to enlarge
Page 63

Appendix B. AMX 68000 Service Procedures

B.1 Summary of Services

AMX 68000 provides a collection of target dependent AMX service procedures for use with the M68000 processor and compatibles and the C compilers which support them. These procedures are summarized below.

Interrupt Control (class ksi )

cjksitrap Install a task trap handler cjksivtp Fetch pointer to the AMX Vector Table cjksivtrd Read an entry from the AMX Vector Table cjksivtwr Write an entry into the AMX Vector Table cjksivtx Exchange an entry in the AMX Vector Table

Processor and C Interface Procedures (class cf )

In addition to the services provided by AMX and its managers, the AMX Library includes several C procedures of a general nature which simplify application programming in real-time systems on your target processor.

cjcfccsetup Setup C environment cjcfdi Disable interrupts at priority level 6 cjcfei Enable interrupts at priority level 0 cjcfflagrd Read the processor status register (SR) cjcfflagwr Write to the processor status register (SR) cjcfhwdelay Delay n microseconds cjcfhwbcache Flush and enable/disable data and instruction caches cjcfhwdcache Flush and enable/disable data cache cjcfhwicache Flush and enable/disable instruction cache cjcfin8 Read an 8-bit input port cjcfin16 Read a 16-bit input port cjcfin32 Read a 32-bit input port cjcfjlong Long jump to a mark set by cjcfjset cjcfjset Set a mark for a subsequent long jump by cjcfjlong cjcfmcopy Copy a block of memory cjcfmset Set (fill) a block of memory cjcfout8 Write an 8-bit value to an output port cjcfout16 Write a 16-bit value to an output port cjcfout32 Write a 32-bit value to an output port cjcfstkjmp Switch stacks and jump to a new procedure cjcftag Convert a string to an AMX tag value cjcfvol8 Read a volatile 8-bit variable cjcfvol16 Read a volatile 16-bit variable cjcfvol32 Read a volatile 32-bit variable cjcfvolpntr Read a volatile pointer variable

AMX 68000 Target Guide KADAK rev7 B-1

Page 64 of the AMX Software (Target Guide) user manual — Appendix B. AMX 68000 Service Procedures
Page 64 · click to enlarge
Page 64

The AMX Library also includes several C procedures which are used privately by KADAK. These procedures, although available for your use, are not documented in this manual and are subject to change at any time. The procedures are briefly described in source file CJZZZUB.ASM. Prototypes will be found in file CJZZZIF.H. The register array structure cjxregs which they use is defined in file CJZZZKT.H.

cjcfregld Load M68000 registers from a register array cjcfregst Store M68000 registers into a register array cjcfsint Generate a software interrupt

B-2 KADAK AMX 68000 Target Guide

Page 65 of the AMX Software (Target Guide) user manual — B.2 Service Procedures
Page 65 · click to enlarge
Page 65

B.2 Service Procedures

A description of all processor dependent AMX 68000 service procedures is provided in this appendix. The descriptions are ordered alphabetically for easy reference.

Italics are used to distinguish programming examples. Procedure names and variable names which appear in narrative text are also displayed in italics. Occasionally a lower case procedure name or variable name may appear capitalized if it occurs as the first word in a sentence.

Vertical ellipses are used in program examples to indicate that a portion of the program code is missing. Most frequently this will occur in examples where fragments of application dependent code are missing.

: : /* Dismiss device interrupt */ :

Capitals are used for all defined AMX filenames, constants and error codes. All AMX procedure, structure and constant names can be readily identified according to the nomenclature introduced in Chapter 1.3 of the AMX User's Guide.

A consistent style has been adopted for each description. The procedure name is presented at the extreme top right and left as in a dictionary. This method of presentation has been chosen to make it easy to find procedures since they are ordered alphabetically.

Purpose A one-line statement of purpose is always provided.

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

This block is used to indicate which of your AMX application procedures can call the AMX procedure. The term ISP refers to the Interrupt Handler of a conforming ISP. A filled in box indicates that the procedure is allowed to call the AMX procedure. In the above example, only tasks and Restart Procedures would be allowed to call the procedure.

Setup The prototype of the AMX procedure is shown. The AMX header file in which the prototype is located is identified. Include AMX header file CJZZZ.H for compilation.

File CJZZZ.H is a generic AMX include file which automatically includes the correct subset of the AMX header files for a particular target processor. If you include CJZZZ.H instead of its KADAK part numbered counterpart (CJnnn.H), your AMX application source modules will be readily portable to other processors without editing.

Description Defines all input parameters to the procedure and expands upon the purpose or method if required.

AMX 68000 Target Guide KADAK rev7 B-3

Page 66 of the AMX Software (Target Guide) user manual — B.2 Service Procedures
Page 66 · click to enlarge
Page 66

Interrupts AMX procedures frequently must deal with the processor interrupt mask. The effect of each AMX procedure on the interrupt state is defined according to the following legend.

Disabled Enabled Restored (Not in ISP) D E R Effect on Interrupts

Untouched

Disabled and left disabled upon return

Enabled and left enabled upon return

Disabled and then enabled upon return

Disabled and then, prior to return, restored to the state in effect upon entry to the procedure

Disabled, possibly briefly enabled and then, prior to return, restored to the state in effect upon entry to the procedure

The warning (Not in ISP) will be present as a reminder that when the Interrupt Handler of a conforming ISP calls the AMX procedure, interrupts will NOT be explicitly enabled by the AMX procedure. If interrupts are enabled when an Interrupt Handler calls the AMX procedure, they will be enabled upon return.

Returns The outputs, if any, produced by the procedure are always defined.

Most AMX procedures return an integer error status identified as a CJ_ERRST. Note that CJ_ERRST is not a C data type. CJ_ERRST is defined (using #define) to be an int allowing error codes to be easily handled as integers but readily identified as AMX error codes.

Restrictions If any restrictions on the use of the procedure exist, they are described.

Task Switch Task switching effects, if any, are described.

Example An example is provided for each of the more complex AMX procedures. The examples are kept simple and are intended only to illustrate the correct calling sequence.

See Also A cross reference to other related AMX procedures is always provided if applicable.

B-4 rev7 KADAK AMX 68000 Target Guide

Page 67 of the AMX Software (Target Guide) user manual — cjcfccsetup cjcfccsetup
Page 67 · click to enlarge
Page 67

cjcfccsetup cjcfccsetup

Purpose Setup C Environment

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype is in file CJZZZIF.H. #include "CJZZZ.H" void CJ_CCPP cjcfccsetup(void);

Description Use cjcfccsetup to setup all low level processor registers to meet the requirements of a particular C compiler. For example, the C compiler may assume that some data variables can be accessed using a particular register which always points to the data. However, when mixing languages, you may find that when a C procedure is called from assembly language, the register assumptions are not valid. A call to cjcfccsetup on entry to the C procedure will setup the correct register content.

Interrupts Disabled Enabled Restored

Returns The registers, if any, which are required by C are set to the values which they contained when AMX was launched.

Restrictions Use cjcfccsetup with care. You may inadvertently cause a register to be set which violates the register preservation rules of the other language.

AMX 68000 Target Guide KADAK B-5

Page 68 of the AMX Software (Target Guide) user manual — cjcfdi cjcfdi cjcfei cjcfei
Page 68 · click to enlarge
Page 68

cjcfdi cjcfdi cjcfei cjcfei

Purpose Disable or Enable Interrupts

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure (cjcfdi only)

Setup Prototype in file CJZZZTF.H or macro in file CJZZZCC.H. #include "CJZZZ.H" void CJ_CCPP cjcfdi(void); void CJ_CCPP cjcfei(void);

Description Tasks can use cjcfdi to briefly disable all sources of interrupt. Immediately thereafter the task can use cjcfei to enable all sources of interrupt again.

Interrupts Disabled by cjcfdi Enabled by cjcfei

The interrupt priority in the status register (SR) is set to 6 to disable interrupts or reset to 0 to enable interrupts.

Restrictions ISPs must not use cjcfei. If nested interrupts are supported in your application, ISPs must always use cjcfflagwr to restore interrupts to the state determined by an earlier call to cjcfflagrd.

Interrupts should be enabled within a short time after they are disabled or system performance will be degraded.

See Also cjcfflagrd, cjcfflagwr

B-6 KADAK AMX 68000 Target Guide

Returns Nothing

Page 69 of the AMX Software (Target Guide) user manual — cjcfflagrd cjcfflagrd cjcfflagwr cjcfflagwr
Page 69 · click to enlarge
Page 69

cjcfflagrd cjcfflagrd cjcfflagwr cjcfflagwr

Purpose Read or Write Processor Status Register

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype in file CJZZZTF.H or macro in file CJZZZCC.H. #include "CJZZZ.H" CJ_TYFLAGS CJ_CCPP cjcfflagrd(void); void CJ_CCPP cjcfflagwr(CJ_TYFLAGS flags);

Description Cjcfflagrd returns the actual state of the processor status register (SR).

Cjcfflagwr updates the processor status register (SR) by writing the parameter flags to the register.

Use cjcfflagrd to read the state of the processor status register, thereby capturing the current interrupt state. Then use cjcfdi to briefly disable all sources of interrupt. Immediately thereafter, use cjcfflagwr to restore the state of the interrupt system.

Interrupts Untouched by cjcfflagrd Restored by cjcfflagwr

Returns Cjcfflagrd returns the actual state of the processor status register. Cjcfflagwr returns nothing.

Cjcfflagwr unconditionally copies flags into the processor status register, thereby enabling or disabling interrupts. Since no validation of flags is performed, caution in the use of cjcfflagwr is advised.

See Also cjcfdi, cjcfei

AMX 68000 Target Guide KADAK B-7

Page 70 of the AMX Software (Target Guide) user manual — cjcfhwdelay cjcfhwdelay
Page 70 · click to enlarge
Page 70

cjcfhwdelay cjcfhwdelay

Purpose Delay n Microseconds

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype is in file CJZZZIF.H. #include "CJZZZ.H" void CJ_CCPP cjcfhwdelay(int n);

Description n is the delay interval measured in microseconds.

Use cjcfhwdelay to generate a software delay loop of approximately n microseconds. This procedure is intended for use in device drivers which must introduce device access delays to avoid violating the minimum timing delay needed between sequential references to a device I/O port.

The ...DELAY directive in your Target Parameter File is used by AMX to derive the delay loop count needed to produce an n microsecond delay.

Interrupts Disabled Enabled Restored

If the ...DELAY directive in your Target Parameter File indicates that the processor frequency is 0, then you must install the frequency value into the public long variable cjcfhwdelayf prior to launching AMX. If you call procedure cjcfhwdelay() prior to launching AMX, be sure that variable cjcfhwdelayf is initialized before making the call.

B-8 KADAK AMX 68000 Target Guide

Returns Nothing

Page 71 of the AMX Software (Target Guide) user manual — cjcfhwbcache cjcfhwbcache cjcfhwdcache cjcfhwdcache cjcfhwicache cjcfhwicache
Page 71 · click to enlarge
Page 71

cjcfhwbcache cjcfhwbcache cjcfhwdcache cjcfhwdcache cjcfhwicache cjcfhwicache

Purpose Flush and Enable/Disable Caches

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype in file CJZZZIF.H. #include "CJZZZ.H" void CJ_CCPP cjcfhwbcache(int operation); void CJ_CCPP cjcfhwdcache(int operation); void CJ_CCPP cjcfhwicache(int operation);

Description operation = 0 to force the caches to be flushed and disabled.

operation = 1 to force the caches to be flushed and enabled.

Interrupts Disabled Enabled Restored

Returns Nothing Cjcfhwbcache flushes and disables (or enables) both the data and instruction caches.

Cjcfhwdcache flushes and disables (or enables) only the data cache.

Cjcfhwicache flushes and disables (or enables) only the instruction cache.

Restrictions ISPs and Timer Procedures must not use these procedures. Since interrupts are disabled while the caches are flushed, use caution when calling these procedures or system performance will be degraded, especially if the cache sizes are large.

AMX 68000 Target Guide KADAK B-9

Page 72 of the AMX Software (Target Guide) user manual — cjcfin8 cjcfin8 cjcfin16 cjcfin16 cjcfin32 cjcfin32
Page 72 · click to enlarge
Page 72

cjcfin8 cjcfin8 cjcfin16 cjcfin16 cjcfin32 cjcfin32

Purpose Read an 8, 16 or 32-Bit Input Port

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype in file CJZZZTF.H or macro in file CJZZZCC.H. #include "CJZZZ.H" CJ_T8 CJ_CCPP cjcfin8(void *port); CJ_T16 CJ_CCPP cjcfin16(void *port); CJ_T32 CJ_CCPP cjcfin32(void *port);

Description port is the address of an 8, 16 or 32-bit memory-mapped device input

port.

Interrupts Disabled Enabled Restored

Returns Cjcfin8 returns an 8-bit signed value. Cjcfin16 returns a 16-bit signed value. Cjcfin32 returns a 32-bit signed value.

Example #include "CJZZZ.H"

/* Console status register */ #define CONSTAT ((CJ_T8 *)0xFFFA002DL)

/* Console data register */ #define CONDATA ((CJ_T8 *)0xFFFA002FL)

void CJ_CCPP conout(char ch) {

/* Wait for ready */ while ( (cjcfin8(CONSTAT) & 0x80) == 0 )

/* Write character */ cjcfout8(CONDATA, (CJ_T32)ch); }

See Also cjcfout8, cjcfout16, cjcfout32

B-10 KADAK AMX 68000 Target Guide

;

Page 73 of the AMX Software (Target Guide) user manual — cjcfjlong cjcfjlong cjcfjset cjcfjset
Page 73 · click to enlarge
Page 73

cjcfjlong cjcfjlong cjcfjset cjcfjset

Purpose cjcfjset Sets a Mark for a Long Jump cjcfjlong Long Jumps to that Mark

These procedures are provided for AMX portability. They are not replacements for C library procedures longjmp or setjmp although they function in a similar manner.

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype is in file CJZZZTF.H. #include "CJZZZ.H" void CJ_CCPP cjcfjlong(struct cjxjbuf *jbuf, int value); int CJ_CCPP cjcfjset(struct cjxjbuf *jbuf);

Description jbuf is a pointer to a jump buffer to be used to mark the processor state at

the time cjcfjset is called and to restore that state when cjcfjlong is subsequently called.

The processor dependent structure cjxjbuf is defined in file CJZZZCC.H.

value is an integer value to be returned to the cjcfjset caller when

cjcfjlong initiates the long jump return. Value cannot be 0. If value = 0, cjcfjlong will replace it with value = 1.

Interrupts Disabled Enabled Restored

Returns Cjcfjset returns 0 when initially called to establish the mark. Cjcfjset returns value (non 0) when cjcfjlong is called to do the long jump to the mark established by the initial cjcfjset call.

There is no return from cjcfjlong.

Restrictions Cjcfjset must be called prior to any call to cjcfjlong. Each call must reference the same jump buffer. The jump buffer must remain unaltered between the initial cjcfjset call and the subsequent cjcfjlong long jump return.

Under no circumstances should one task attempt a long jump using a jump buffer set by another task.

AMX 68000 Target Guide KADAK B-11

Page 74 of the AMX Software (Target Guide) user manual — B.2 Service Procedures
Page 74 · click to enlarge
Page 74

Example #include "CJZZZ.H"

void CJ_CCPP dowork(struct cjxjbuf *jbp);

static struct cjxjbuf jumpbuffer;

#define STACKSIZE 512 /* Stack size (longs) */ #define STACKDIR 1 /* 0=grows up; 1=grows down */ static long newstack[STACKSIZE];

#if (STACKDIR == 1) #define STACKP (&newstack[STACKSIZE - 1]) #else #define STACKP newstack #endif

void CJ_CCPP taskbody(void) {

if (cjcfjset(&jumpbuffer) == 0)

/* Switch to new stack and do work */ cjcfstkjmp(&jumpbuffer, STACKP,

(CJ_VPPROC)dowork); /* Never returns to here */

/* Do work using original stack */ dowork(NULL); }

void CJ_CCPP dowork(struct cjxjbuf *jbp) {

/* Do work */

/* If jump buffer provided, then use long jump to */ /* restore the original stack and return */ if (jbp != NULL)

B-12 KADAK AMX 68000 Target Guide

cjcfjlong(jbp, 1); } · See Also cjcfstkjmp

Page 75 of the AMX Software (Target Guide) user manual — cjcfmcopy cjcfmcopy cjcfmset cjcfmset
Page 75 · click to enlarge
Page 75

cjcfmcopy cjcfmcopy cjcfmset cjcfmset

Purpose Copy a Block of Memory Set (Fill) a Block of Memory

These procedures are provided for AMX portability. They are not replacements for C library procedures memcpy or memset.

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype is in file CJZZZTF.H. #include "CJZZZ.H" void CJ_CCPP cjcfmcopy(int *sourcep, int *destp,

unsigned int size); void CJ_CCPP cjcfmset(int *mempntr,

unsigned int size, int pattern);

Description sourcep is a pointer to the integer aligned block of memory which is to be

copied to the destination.

destp is a pointer to the integer aligned block of memory which is the

destination of the block being copied.

mempntr is a pointer to the integer aligned block of memory which is to be

filled with pattern.

size is the number of integers to be copied or set. The number of bytes

copied or set will therefore be size * sizeof(int).

Interrupts Disabled Enabled Restored

Restrictions The source and destination blocks must not overlap unless destp is lower in memory than sourcep.

ISPs and Timer Procedures should not fill or copy large blocks of memory. Failure to observe this restriction may impose serious performance penalties on your application.

Example #include "CJZZZ.H"

#define BLOCKSIZE 1024 static int srcarray[BLOCKSIZE]; static int dstarray[BLOCKSIZE];

void CJ_CCPP blocksetcopy(int pattern) {

cjcfmset(srcarray, sizeof(srcarray), pattern); cjcfmcopy(srcarray, dstarray, sizeof(srcarray)); }

AMX 68000 Target Guide KADAK B-13

Returns Nothing

Page 76 of the AMX Software (Target Guide) user manual — cjcfout8 cjcfout8 cjcfout16 cjcfout16 cjcfout32 cjcfout32
Page 76 · click to enlarge
Page 76

cjcfout8 cjcfout8 cjcfout16 cjcfout16 cjcfout32 cjcfout32

Purpose Write to an 8, 16 or 32-Bit Output Port

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype in file CJZZZTF.H or macro in file CJZZZCC.H. #include "CJZZZ.H" void CJ_CCPP cjcfout8(void *port, CJ_T32 data); void CJ_CCPP cjcfout16(void *port, CJ_T32 data); void CJ_CCPP cjcfout32(void *port, CJ_T32 data);

Description port is the address of an 8, 16 or 32-bit memory-mapped device output

port.

data is the 8, 16 or 32-bit value to be output to the port.

Interrupts Disabled Enabled Restored

Returns Nothing Cjcfout8 outputs the least significant 8 bits of data to the port. Cjcfout16 outputs the least significant 16 bits of data to the port. Cjcfout32 outputs the full 32 bits of data to the port.

Example #include "CJZZZ.H"

/* Console status register */ #define CONSTAT ((CJ_T8 *)0xFFFA002DL)

/* Console data register */ #define CONDATA ((CJ_T8 *)0xFFFA002FL)

void CJ_CCPP conout(char ch) {

/* Wait for ready */ while ( (cjcfin8(CONSTAT) & 0x80) == 0 )

/* Write character */ cjcfout8(CONDATA, (CJ_T32)ch); }

See Also cjcfin8, cjcfin16, cjcfin32

B-14 KADAK AMX 68000 Target Guide

;

Page 77 of the AMX Software (Target Guide) user manual — cjcfstkjmp cjcfstkjmp
Page 77 · click to enlarge
Page 77

cjcfstkjmp cjcfstkjmp

Purpose Switch Stacks and Jump to a New Procedure

This procedure is provided for AMX portability.

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype is in file CJZZZTF.H. #include "CJZZZ.H" void CJ_CCPP cjcfstkjmp(void *vp, void *stackp,

Description vp is a pointer which is passed as a parameter to the new procedure.

stackp is a pointer to a properly aligned block of memory for use as a

stack. For the M68000 family, the stack must be 16-bit word aligned. For some M68000 processors, performance will be improved if the stack is 32-bit long word aligned.

Stackp must point to the top of the memory block since the processor stack builds downward by popular convention.

procp is a pointer to the new procedure which is prototyped as follows:

void CJ_CCPP newfunc(void *vp);

For portability using different C compilers, cast your procedure pointer as (CJ_VPPROC)newfunc in your call to cjcfstkjmp.

Interrupts Disabled Enabled Restored

Returns There is no return from cjcfstkjmp. Use cjcfjset and cjcfjlong if there is a requirement to return to the original stack.

Restrictions The new procedure referenced by procp must never return. The procedure can call cjtkend to end the calling task.

Example See the example provided with cjcfjset and cjcfjlong.

See Also cjcfjlong, cjcfjset, cjtkend

AMX 68000 Target Guide KADAK B-15

CJ_VPPROC procp);

Page 78 of the AMX Software (Target Guide) user manual — cjcftag cjcftag
Page 78 · click to enlarge
Page 78

cjcftag cjcftag

Purpose Convert a String to an Object Name Tag

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype is in file CJZZZTF.H. #include "CJZZZ.H" CJ_TYTAG CJ_CCPP cjcftag(char *tag);

Description tag is a pointer to a string which is a one to four character name tag.

Interrupts Disabled Enabled Restored

Returns The name tag string is converted to a 32-bit name tag value of type CJ_TYTAG which is returned to the caller.

If the name tag string is less than four characters, the returned name tag value is 0 filled. If the name tag string is longer than four characters, the returned name tag value is limited to the first four characters of the string.

Example See any of the cjXXbuild examples in which an object name tag string is converted to a name tag value for insertion into the object definition structure.

See Also cjksfind, cjksgbfind

B-16 KADAK AMX 68000 Target Guide

Page 79 of the AMX Software (Target Guide) user manual — cjcfvol8 cjcfvol8 cjcfvol16 cjcfvol16 cjcfvol32 cjcfvol32 cjcfvolpntr cjcfvolpntr
Page 79 · click to enlarge
Page 79

cjcfvol8 cjcfvol8 cjcfvol16 cjcfvol16 cjcfvol32 cjcfvol32 cjcfvolpntr cjcfvolpntr

Purpose Fetch a Volatile 8-Bit, 16-Bit, 32-Bit or Pointer Value

Use these procedures to fetch the content of a volatile variable if the C compiler does not support the C keyword volatile. These procedures (or macros) also guarantee that multiple byte fetches will be done in an indivisible fashion.

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype in file CJZZZTF.H or macro in file CJZZZCC.H. #include "CJZZZ.H" CJ_T8 CJ_CCPP cjcfvol8(void *varp); CJ_T16 CJ_CCPP cjcfvol16(void *varp); CJ_T32 CJ_CCPP cjcfvol32(void *varp); void * CJ_CCPP cjcfvolpntr(void *pntrp);

Description varp is a pointer to an 8, 16 or 32-bit variable.

pntrp is a pointer to a pointer variable.

Interrupts Disabled Enabled Restored

Returns Cjcfvol8 returns an 8-bit signed value from *varp. Cjcfvol16 returns a 16-bit signed value from *varp. Cjcfvol32 returns a 32-bit signed value from *varp. Cjcfvolpntr returns a pointer from *pntrp.

Example #include "CJZZZ.H"

extern CJ_T8 controlflag; /* Volatile control flag */ extern int *valuep; /* Volatile pointer */

int * CJ_CCPP readpntr(void) {

/* Wait until access allowed */ while (cjcfvol8(&controlflag) == 0)

/* Wait for valid pointer */ while ((pntr = (int *)cjcfvolpntr(&valuep)) == CJ_NULL)

controlflag = 0; return (pntr); }

AMX 68000 Target Guide KADAK B-17

int *pntr; · ; · ;

Page 80 of the AMX Software (Target Guide) user manual — B.2 Service Procedures
Page 80 · click to enlarge
Page 80

This page left blank intentionally.

B-18 KADAK AMX 68000 Target Guide

Page 81 of the AMX Software (Target Guide) user manual — cjksitrap cjksitrap
Page 81 · click to enlarge
Page 81

cjksitrap cjksitrap

Purpose Install a Task Trap Handler

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype is in file CJZZZIF.H. #include "CJZZZ.H" CJ_ERRST CJ_CCPP cjksitrap(int trapid, CJ_TRAPPROC handler);

Description trapid is the processor vector number which identifies the particular error

trap.

CJ_PRVNZD Zero divide trap CJ_PRVNCH CHK (bounds check) instruction trap CJ_PRVNTV TRAPV (overflow test) instruction trap

handler is a pointer to the task's trap handler for the particular error trap.

Interrupts Disabled Enabled Restored

Returns Error status is returned.

CJ_EROK Call successful.

Errors returned:

CJ_ERTKTRAP Trapid is not a vector number for which task traps are allowed.

AMX 68000 Target Guide KADAK B-19

Page 82 of the AMX Software (Target Guide) user manual — cjksivtp cjksivtp
Page 82 · click to enlarge
Page 82

cjksivtp cjksivtp

Purpose Fetch Pointer to the AMX Vector Table

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype is in file CJZZZIF.H. #include "CJZZZ.H" void * CJ_CCPP cjksivtp(void);

Interrupts Disabled Enabled Restored

Returns A pointer to the AMX Vector Table.

See Also cjksivtrd, cjksivtwr, cjksivtx

B-20 KADAK AMX 68000 Target Guide

Page 83 of the AMX Software (Target Guide) user manual — cjksivtrd cjksivtrd
Page 83 · click to enlarge
Page 83

cjksivtrd cjksivtrd

Purpose Read from the AMX Vector Table

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype is in file CJZZZIF.H. #include "CJZZZ.H" CJ_ERRST CJ_CCPP cjksivtrd(int vector, CJ_ISPPROC *oldproc);

Description vector is the processor vector number (0 to 255).

Vectors 12, 16 to 23 and 59 to 63 are reserved by Motorola.

oldproc is a pointer to storage for a copy of the Interrupt Service

Procedure pointer (or exception service procedure pointer) retrieved from the specified entry in the AMX Vector Table.

Interrupts Disabled Enabled Restored

Returns Error status is returned.

CJ_EROK Call successful. *oldproc contains the Interrupt Service Procedure pointer (or exception service procedure pointer) retrieved from AMX Vector Table entry number vector.

Errors returned:

See Also cjksivtwr, cjksivtx

AMX 68000 Target Guide KADAK B-21

None

Page 84 of the AMX Software (Target Guide) user manual — cjksivtwr cjksivtwr
Page 84 · click to enlarge
Page 84

cjksivtwr cjksivtwr

Purpose Write to the AMX Vector Table

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype is in file CJZZZIF.H. #include "CJZZZ.H" CJ_ERRST CJ_CCPP cjksivtwr(int vector, CJ_ISPPROC newproc);

Description vector is the processor vector number (0 to 255).

Vectors 12, 16 to 23 and 59 to 63 are reserved by Motorola.

newproc is a pointer to the new Interrupt Service Procedure.

Interrupts Disabled Enabled Restored

Returns Error status is returned.

CJ_EROK Call successful.

Errors returned:

CJ_ERNOACCESS AMX Vector Table is not accessible.

AMX was launched with access to its Vector Table denied.

Restrictions You must NOT use this procedure to alter the task trap vectors (vector = CJ_PRVNZD, CJ_PRVNCH or CJ_PRVNTV). Use cjksitrap for that purpose.

See Also cjksivtrd, cjksivtx

B-22 KADAK AMX 68000 Target Guide

Page 85 of the AMX Software (Target Guide) user manual — cjksivtx cjksivtx
Page 85 · click to enlarge
Page 85

cjksivtx cjksivtx

Purpose Exchange an Entry in the AMX Vector Table

Used by Task ISP Timer Procedure Restart Procedure Exit Procedure

Setup Prototype is in file CJZZZIF.H. #include "CJZZZ.H" CJ_ERRST CJ_CCPP cjksivtx(int vector,

CJ_ISPPROC newproc, CJ_ISPPROC *oldproc);

Description vector is the processor vector number (0 to 255).

Vectors 12, 16 to 23 and 59 to 63 are reserved by Motorola.

newproc is a pointer to the new Interrupt Service Procedure.

oldproc is a pointer to storage for the previous Interrupt Service

Procedure pointer (or exception service procedure pointer) retrieved from the AMX Vector Table.

Interrupts Disabled Enabled Restored

Returns Error status is returned.

CJ_EROK Call successful. *oldproc contains the previous Interrupt Service Procedure pointer (or exception service procedure pointer).

Errors returned:

For all errors, *oldproc is undefined on return. CJ_ERNOACCESS AMX Vector Table is not accessible.

AMX was launched with access to its Vector Table denied.

Restrictions You must NOT use this procedure to alter the task trap vectors (vector = CJ_PRVNZD, CJ_PRVNCH or CJ_PRVNTV). Use cjksitrap for that purpose.

See Also cjksivtrd, cjksivtwr

AMX 68000 Target Guide KADAK B-23

Page 86 of the AMX Software (Target Guide) user manual — B.2 Service Procedures
Page 86 · click to enlarge
Page 86

This page left blank intentionally.

B-24 KADAK AMX 68000 Target Guide

Page 87 of the AMX Software (Target Guide) user manual — Selecting AMX ROM Options
Page 87 · click to enlarge
Page 87

Appendix C. AMX 68000 ROM Option

An AMX system can be configured in two ways. The particular configuration is chosen to best meet your application needs.

Most AMX systems are linked. Your AMX application is linked with your System Configuration Module, your Target Configuration Module and the AMX Library. The resulting load module is then copied to memory for execution either by loading the image into RAM or by committing the image to ROM. Such a ROM contains an image of your application merged with AMX in an inseparable fashion.

The AMX ROM option offers an alternate method of committing AMX to ROM. The ROM option allows the subset of AMX and its managers required by your application to be linked together without any application code to form a separate AMX ROM image. The resulting ROM can be located anywhere in your memory configuration. The penalty paid for ROMing in this fashion is slightly slower access by application code to AMX services.

Selecting AMX ROM Options

To support an AMX ROM system, the following files are provided.

CJ532ROP.LKT AMX ROM Option toolset dependent Link Specification Template CJ532ROP.CT AMX ROM Option Template CJ532RAC.CT AMX ROM Access Template

To use the AMX ROM option, you must edit your Target Parameter File to identify the AMX components which you wish to place in the AMX ROM and to specify where the AMX ROM is to be located. You can use the AMX Configuration Builder to enter these parameters as described in Chapter 4.6.

AMX 68000 Target Guide KADAK C-1

Page 88 of the AMX Software (Target Guide) user manual — CJ532CG HDWCFG.UP CJ532ROP.CT CJ532ROP.ASM
Page 88 · click to enlarge
Page 88

Creating an AMX ROM

The AMX ROM is created by using the AMX Configuration Generator to produce a ROM Option Module which is then linked with the AMX Library to form an AMX ROM image.

The Configuration Generator combines the information in your Target Parameter File with the ROM Option Template file CJ532ROP.CT to produce an assembly language ROM Option Module CJ532ROP.ASM.

You can use the AMX Configuration Builder to generate the ROM Option Module. Use the AMX Configuration Manager to open your Target Parameter File. Make the ROM Option Module selector the active selector. The ROM Option window will become visible allowing you to view your ROM option parameters. To generate the ROM Option Module, select Generate... from the File menu.

If you are unable to use the AMX Configuration Manager or are creating your ROM Option Module from within a make file, you can use the stand alone version of the Configuration Generator. If your Target Parameter File is named HDWCFG.UP, the stand alone version of the Configuration Generator utility is invoked as follows:

CJ532CG HDWCFG.UP CJ532ROP.CT CJ532ROP.ASM

The ROM Option Module CJ532ROP.ASM is then assembled in exactly the same manner as your Target Configuration Module HDWCFG.ASM according to the directions in the AMX Tool Guides.

The AMX ROM is linked according to the directions in the AMX Tool Guides.

The resulting AMX ROM image file is then committed to ROM using conventional ROM burning tools. The manner in which this is accomplished will depend completely upon your development environment. In general, the process involves the transfer of the AMX ROM hex file to a PROM programmer.

C-2 KADAK AMX 68000 Target Guide

Page 89 of the AMX Software (Target Guide) user manual — CJ532CG HDWCFG.UP CJ532RAC.CT CJ532RAC.ASM
Page 89 · click to enlarge
Page 89

Linking for AMX ROM Access

The AMX Configuration Generator is used to produce a ROM Access Module which, when linked with your application, provides access to AMX in the AMX ROM.

The Configuration Generator combines the information in your Target Parameter File with the ROM Access Template file CJ532RAC.CT to produce an assembly language ROM Access Module CJ532RAC.ASM.

You can use the AMX Configuration Builder to generate the ROM Access Module. Use the AMX Configuration Manager to open your Target Parameter File. Make the ROM Access Module selector the active selector. The ROM Option window will become visible allowing you to view your ROM option parameters. To generate the ROM Access Module, select Generate... from the File menu.

If you are unable to use the AMX Configuration Manager or are creating your ROM Access Module from within a make file, you can use the stand alone version of the Configuration Generator. If your Target Parameter File is named HDWCFG.UP, the stand alone version of the Configuration Generator utility is invoked as follows:

CJ532CG HDWCFG.UP CJ532RAC.CT CJ532RAC.ASM

The ROM Access Module CJ532RAC.ASM is then assembled in exactly the same manner as your Target Configuration Module HDWCFG.ASM according to the directions in the AMX Tool Guides.

The AMX ROM Access Module provides access to all of the procedures of AMX and the subset of AMX managers which you included in your AMX ROM. These ROM access procedures make software jumps to the ROM resident procedures.

To create an AMX system which uses your AMX ROM, proceed just as though you were going to include AMX as part of a linked system. Your System Configuration Module must indicate that AMX and its managers are in a separate ROM. To meet this requirement, you may have to use the AMX Configuration Manager to edit your User Parameter File accordingly and regenerate your System Configuration Module. If you do so, do not forget to recompile the System Configuration Module.

Your AMX application is then linked as described in the AMX Tool Guides. However, since AMX and a subset of its managers are in ROM, you must include the AMX ROM Access Module CJ532RAC.OBJ in your list of object modules to be linked. By so doing, you will preclude the inclusion of AMX and its managers from the AMX Library CJ532.LIB.

AMX 68000 Target Guide KADAK C-3

Page 90 of the AMX Software (Target Guide) user manual — Moving the AMX ROM
Page 90 · click to enlarge
Page 90

Once linked, your AMX application can be downloaded into RAM memory in your target hardware configuration. Alternatively, your application can be transferred to ROM using the same techniques that were used to produce the AMX ROM. Regardless of the manner in which your AMX system is loaded into your target hardware, access to the AMX ROM via the ROM Access Module is now possible.

For simplicity, the complexities which you will encounter when trying to commit the C Runtime Library to ROM have been ignored. Refer to your C compiler reference manual for guidance in ROMing C code and data in embedded applications.

If your AMX ROM was created without a particular manager, then an AMX fatal exit will occur if your system attempts to access that manager.

Moving the AMX ROM

The AMX ROM is not position independent. Nor is the location of the RAM used by AMX.

To move either, you must edit the AMX ROM option parameters in your Target Parameter File to define the new location of the AMX ROM and its RAM. Reconstruct a new AMX ROM image and burn a new AMX ROM. Then rebuild the AMX ROM Access Module and relink your AMX system with it.

C-4 KADAK AMX 68000 Target Guide

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the AMX Software (Target Guide)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the AMX Software (Target Guide)

Be the first to ask — other owners or our team will answer.

Original document

AMX Software (Target Guide) manual PDF

90 pages·307 KB·Software·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…