Page 1 of the Pelco MS504BAF user manual — MS500 Series Manual Switchers
Page 1 · click to enlarge
Page 1

MS500 Series Manual Switchers

Installation/ Operation Manual

C820M-D (1/01)

  • Pelco
  • 3500 Pelco Way, Clovis
  • CA 93612-5699 USA
  • <a href="http://www.pelco.com" rel="nofollow noopener" target="_blank">www.pelco.com</a> In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120
Page 3 of the Pelco MS504BAF user manual — C A U T I O N :
Page 3 · click to enlarge
Page 3

IMPORTANT SAFEGUARDS AND WARNINGS

Prior to installation and use of this product, the following WARNINGS should be observed.

1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.

The product and/or manual may bear the following marks:

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.

C A U T I O N :

RISK OF ELECTRIC SHOCK.

This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

DO NOT OPEN.

Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.

Page 4 of the Pelco MS504BAF user manual — MODELS
Page 4 · click to enlarge
Page 4

DESCRIPTION

The MS500 Series provides an inexpensive and reliable method of switching 4 to 18 inputs to a single monitor output using interlocked manual pushbuttons. Included in this series is the MS540 switcher with two monitor outputs and the capacity to switch up to 40 inputs with a 14 pushbutton panel.

The MS500 Series Switchers are designed for either looping or terminating operation, depending on the model.

MODELS

Terminating MS504DT 4 inputs (UL) MS508DT 8 inputs (UL) MS512DT 12 inputs (UL) MS518DT 18 inputs (UL) MS540DT 40 inputs (UL) MS504GDT 4 inputs, illuminated buttons, 120 VAC (UL) MS508GDT Same as MS504GDT, 8 inputs (UL) MS512GDT Same as MS504GDT, 12 inputs (UL) MS512GDT/220 Same as MS512GDT except 230 VAC MS518GDT Same as MS504GDT, 18 inputs (UL)

Terminating With Audio Follow MS504AF 4 inputs (UL) MS508AF 8 inputs (UL) MS512AF 12 inputs (UL) MS518AF 18 inputs (UL)

Terminating With Balanced Audio Follow MS504BAF 4 inputs (UL) MS508BAF 8 inputs (UL) MS512BAF 12 inputs (UL)

Looping MS504LDT 4 inputs (UL) MS508LDT 8 inputs (UL) MS512LDT 12 inputs (UL) MS518LDT 18 inputs (UL) MS540LDT 40 inputs, 2 monitor outputs 120 VAC (UL) MS540LDT/220 Same as MS540LDT except 230 VAC MS504GLDT 4 inputs, illuminated buttons, 120 VAC input (UL) MS504GLDT/220 Same as MS504GLDT except 230 VAC MS508GLDT Same as MS504GLDT, 8 inputs (UL) MS512GLDT Same as MS504GLDT, 12 inputs (UL) MS512GLDT/220 Same as MS512GLDT except 230 VAC MS518GLDT Same as MS504GLDT, 18 inputs (UL)

Looping With Audio Follow MS504AFL 4 inputs (UL) MS508AFL 8 inputs (UL) MS512AFL 12 inputs (UL) MS518AFL 18 inputs (UL)

Looping With Balanced Audio Follow MS504BAFL 4 inputs (UL) MS508BAFL 8 inputs (UL) MS512BAFL 12 input (UL)INSTALLATION

Page 5 of the Pelco MS504BAF user manual — MS504AF (REAR VIEW)
Page 5 · click to enlarge
Page 5

INSTALLATION

1. Place the unit on a flat surface, or install it in an equipment rack using the appropriate rack-mount kit.
2. Refer to Figures 1 - 6 and select the desired configuration for your installation. Make all equipment connections as illustrated in the drawings. Refer to Table A for the type of coaxial cable to use.
3. Plug in the power cord. The switcher will begin operating.

Table A. Video Coaxial Cable Requirements

Cable Type*Maximum Distance RG59/U RG6/U RG11/U750 ft (229 m) 1,000 ft (305 m) 1,500 ft (457 m)
* Minimum cable requirements75 ohms impedance All-copper center conductor All-copper braided shield with 95% braid coverage

TERMINATING SWITCHERS

When using non-looping switchers, the monitor should be terminated unless the looping output, if available, on the monitor is used. (Refer to Figures 1 and 2.)

Pelco MS504BAF — TERMINATING SWITCHERS diagram (page 5)
Fig. 1

Figure 1. MS500 Series Switchers - Terminating Configuration

Pelco MS504BAF — Figure 1. MS500 Series Switchers - Terminating Configuration diagram (page 5)
Fig. 2 · Figure 1. MS500 Series Switchers - Terminating Confi…

MS504AF (REAR VIEW)

Figure 2. MS500 Series Switchers - Terminating Configuration with Coaxitron ® Transmitter

Page 6 of the Pelco MS504BAF user manual — Figure 4. MS500 Series Switchers - Looping Configuration with Coaxitron Transmitter
Page 6 · click to enlarge
Page 6

LOOPING SWITCHERS

Use coaxial cable to connect the input and looping video cables to the appropriate input connectors. Connect the monitor(s) to the monitor output. (Refer to Figures 3 and 4.) IMPORTANT: Looping switchers do not have inter- nal termination. Inputs must be terminated at 75 ohms by other equipment in the system.

Pelco MS504BAF — LOOPING SWITCHERS diagram (page 6)
Fig. 3

Figure 3. MS500 Series Switchers - Looping Configuration

Pelco MS504BAF — Figure 3. MS500 Series Switchers - Looping Configuration diagram (page 6)
Fig. 4 · Figure 3. MS500 Series Switchers - Looping Configura…

Figure 4. MS500 Series Switchers - Looping Configuration with Coaxitron Transmitter

Page 7 of the Pelco MS504BAF user manual — MS504BAF (REAR VIEW)
Page 7 · click to enlarge
Page 7

SWITCHERS WITH AUDIO FOLLOW

MS500 Series models with “AF” in the suffix have a connection for an audio signal source. Using appropriate cable with compatible connectors, connect audio signal sources to RCA jack (refer to Figure 5).

Pelco MS504BAF — SWITCHERS WITH AUDIO FOLLOW diagram (page 7)
Fig. 5

MS504AF (REAR VIEW)

Figure 5. MS500 Series Switchers with Audio Follow

SWITCHERS WITH BALANCED AUDIO FOLLOW

MS500 Series models with “BAF” in the suffix have terminal block connections for a two- conductor cable. This cable can be used for balanced audio follow or similar signals. (Refer to Figure 6.)

Pelco MS504BAF — MS504AF (REAR VIEW) diagram (page 7)
Fig. 6

OUT A B A B A B A B A B 1 2 3 4

MS504BAF (REAR VIEW)

Figure 6. MS500 Series Switchers with Balanced Audio Follow

Page 8 of the Pelco MS504BAF user manual — MAINTENANCE
Page 8 · click to enlarge
Page 8

SWITCHERS WITH AMPLIFIED OUTPUT

The MS540DT and MS540LDT switchers provide both an amplified output (Monitor 1) and a non-amplified output (Monitor 2). Most installations require the use of Monitor 2 output for proper operations.

OPERATION

To operate the MS500 Series Switcher, plug in the power cord and press a camera button to view video from the corresponding camera.

MAINTENANCE

Regularly scheduled maintenance is not required. However, maintenance may be required in the following situations:

1. For switcher contacts that are not conducting properly, clean with a non-conducting electrical contact spray cleaner especially made for that purpose. Remove cover for access to the contacts and spray cleaner carefully into contacts from the rear.
2. To replace burned out bulbs in illuminated models, remove the switch cover from the front of the unit and push the bulb upwards, then lift out. Replace with Pelco #LAP327.
Page 9 of the Pelco MS504BAF user manual — Figure 8. Schematic for 40 Position Manual swithcers
Page 9 · click to enlarge
Page 9
Pelco MS504BAF — Figure 7. Schematic for 4-18 Position Manual Switchers diagram (page 9)
Fig. 7 · Figure 7. Schematic for 4-18 Position Manual Switche…

-FOR 220 VAC INPUT ADD JUMPER TO 2 & 3

REMOVE JUMPER FROM 1 & 3, 2 & 4

Figure 7. Schematic for 4-18 Position Manual Switchers

Pelco MS504BAF — Figure 7. Schematic for 4-18 Position Manual Switchers diagram (page 9)
Fig. 8 · Figure 7. Schematic for 4-18 Position Manual Switche…

Figure 8. Schematic for 40 Position Manual swithcers

Page 10 of the Pelco MS504BAF user manual — SPECIFICATIONS
Page 10 · click to enlarge
Page 10

SPECIFICATIONS

VIDEO Inputs: 4, 8, 12, or 40 as indicated by the last two digits of the model number.

Video ConnectorsBNC

Audio Connectors:

AF Switchers 1/8-inch RCA phone jack BAF Switchers Terminal block

Termination:

Terminated or Non-looping Switchers

Input 75-ohm internal termination Output 75-ohm source termination Looping Switchers

Input High impedance looping Output High impedance looping

ELECTRICAL (Models MS500G, MS500GL, MS540DT, and MS540LDT)

Input Voltage120 VAC, 50/60 Hz or 230 VAC, 50 Hz
Power Requirement.095 amp (11 vA)
Fuse3 AG 1/16 amp slo-blow
Power Cord3-wire grounded #18 AWG

(Models MS540DT and MS540LDT Only)

Output Amplifier: One amplified output and one non-amplified output for use with MPT9000CZ/MPT9000PZ (Coaxitron® System).

GainUnity
Frequency ResponseFlat within ± 1 dB to 10 MHz
Max. Signal Level2 Vp-p
Page 11 of the Pelco MS504BAF user manual — SPECIFICATIONS
Page 11 · click to enlarge
Page 11
GENERAL SwitchingInterlocked manual pushbuttons

Construction:

Cover Steel, black polyester powder coat Chassis Steel, zinc plated Panel Aluminum, black polyester powder coat

Environment32 ° to 120 ° F (0 ° to 48.89 ° C)

MS504 Series (except AFL, BAF, and BAF models): 1.75 (H) x 5.3 (W) x 9.3 (L) inches (4.45 cm x 13.46 cm x 23.62 cm)

MS504AFL, MS504BAF, MS504BAFL, and MS508 Series (except AFL model): 1.75 (H) x 14.3 (W) x 9.3 (L) inches (4.45 cm x 36.32 cm x 23.62 cm)

MS508AFL, MS512 Series, MS518 Series, and MS540DT (except MS518AFL and MS540LDT): 1.75 (H) x 17.12 (W) x 9.3 (L) inches (4.45 cm x 43.48 cm x 23.62 cm)

MS518AFL and MS540LDT: 3.50 (H) x 17.12 (W) x 9.3 (L) inches (8.89 cm x 43.48 cm x 23.62 cm)

(Design and product specifications subject to change without notice.)

Dimensions

Page 12 of the Pelco MS504BAF user manual — REVISION HISTORY
Page 12 · click to enlarge
Page 12

PRODUCT WARRANTY AND RETURN INFORMATION

WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.

If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: 1. Model and serial number 2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number 3. Details of the defect or problem

Exceptions to this warranty are as noted below:

  • Five years on FT/FR8000 Series fiber optic products.
  • Three years on Genex ® Series products (multiplexers, server, and keyboard).

If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.

  • Three years on Camclosure ® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty.
  • Two years on standard motorized or fixed focal length lenses.

Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.

  • Two years on Legacy ® , CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.

RETURNS In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).

  • Two years on Spectra ® , Esprit ® , ExSite ™ , and PS20 scanners, including when used in continuous motion applications.
  • Two years on Esprit ® and WW5700 Series window wiper (excluding wiper blades).

All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.

  • Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura ™ Series distributed network-based video products.

Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.

  • One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.

If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:

  • Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).

Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699

Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.

If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:

Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.

If the goods are to be sent by a COURIER SERVICE, send the goods to:

Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA

If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:

Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933

The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.

REVISION HISTORY

Manual # Date Comments C820M 3/88 Original version. C820M-A 9/90 Added to Warning Section for UL compliance. C820M-B 6/92 Revised to cover all MS500 Series models. Added DT200 to Options section. C820M-C 10/97 Revised Figures 1 and 2. Put into new format. C820M-D 1/01 Added illustrations for terminated and looping configurations with a Coaxitron transmitter. Updated manual to new format.

® Pelco, the Pelco logo, Spectra, Genex, Legacy, Coaxitron, and PelcoVision are registered trademarks of Pelco. © Copyright 2001, Pelco. ™ Esprit and Camclosure are trademarks of Pelco. All rights reserved.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Pelco MS504BAF

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Pelco MS504BAF

Be the first to ask — other owners or our team will answer.

Original document

Pelco MS504BAF manual PDF

12 pages·229 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…