Installation/ Operation Manual
C820M-D (1/01)


Prior to installation and use of this product, the following WARNINGS should be observed.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
RISK OF ELECTRIC SHOCK.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
DO NOT OPEN.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.

The MS500 Series provides an inexpensive and reliable method of switching 4 to 18 inputs to a single monitor output using interlocked manual pushbuttons. Included in this series is the MS540 switcher with two monitor outputs and the capacity to switch up to 40 inputs with a 14 pushbutton panel.
The MS500 Series Switchers are designed for either looping or terminating operation, depending on the model.
Terminating MS504DT 4 inputs (UL) MS508DT 8 inputs (UL) MS512DT 12 inputs (UL) MS518DT 18 inputs (UL) MS540DT 40 inputs (UL) MS504GDT 4 inputs, illuminated buttons, 120 VAC (UL) MS508GDT Same as MS504GDT, 8 inputs (UL) MS512GDT Same as MS504GDT, 12 inputs (UL) MS512GDT/220 Same as MS512GDT except 230 VAC MS518GDT Same as MS504GDT, 18 inputs (UL)
Terminating With Audio Follow MS504AF 4 inputs (UL) MS508AF 8 inputs (UL) MS512AF 12 inputs (UL) MS518AF 18 inputs (UL)
Terminating With Balanced Audio Follow MS504BAF 4 inputs (UL) MS508BAF 8 inputs (UL) MS512BAF 12 inputs (UL)
Looping MS504LDT 4 inputs (UL) MS508LDT 8 inputs (UL) MS512LDT 12 inputs (UL) MS518LDT 18 inputs (UL) MS540LDT 40 inputs, 2 monitor outputs 120 VAC (UL) MS540LDT/220 Same as MS540LDT except 230 VAC MS504GLDT 4 inputs, illuminated buttons, 120 VAC input (UL) MS504GLDT/220 Same as MS504GLDT except 230 VAC MS508GLDT Same as MS504GLDT, 8 inputs (UL) MS512GLDT Same as MS504GLDT, 12 inputs (UL) MS512GLDT/220 Same as MS512GLDT except 230 VAC MS518GLDT Same as MS504GLDT, 18 inputs (UL)
Looping With Audio Follow MS504AFL 4 inputs (UL) MS508AFL 8 inputs (UL) MS512AFL 12 inputs (UL) MS518AFL 18 inputs (UL)
Looping With Balanced Audio Follow MS504BAFL 4 inputs (UL) MS508BAFL 8 inputs (UL) MS512BAFL 12 input (UL)INSTALLATION

When using non-looping switchers, the monitor should be terminated unless the looping output, if available, on the monitor is used. (Refer to Figures 1 and 2.)


Figure 2. MS500 Series Switchers - Terminating Configuration with Coaxitron ® Transmitter

Use coaxial cable to connect the input and looping video cables to the appropriate input connectors. Connect the monitor(s) to the monitor output. (Refer to Figures 3 and 4.) IMPORTANT: Looping switchers do not have inter- nal termination. Inputs must be terminated at 75 ohms by other equipment in the system.



MS500 Series models with “AF” in the suffix have a connection for an audio signal source. Using appropriate cable with compatible connectors, connect audio signal sources to RCA jack (refer to Figure 5).

Figure 5. MS500 Series Switchers with Audio Follow
SWITCHERS WITH BALANCED AUDIO FOLLOW
MS500 Series models with “BAF” in the suffix have terminal block connections for a two- conductor cable. This cable can be used for balanced audio follow or similar signals. (Refer to Figure 6.)

OUT A B A B A B A B A B 1 2 3 4
Figure 6. MS500 Series Switchers with Balanced Audio Follow

The MS540DT and MS540LDT switchers provide both an amplified output (Monitor 1) and a non-amplified output (Monitor 2). Most installations require the use of Monitor 2 output for proper operations.
To operate the MS500 Series Switcher, plug in the power cord and press a camera button to view video from the corresponding camera.
Regularly scheduled maintenance is not required. However, maintenance may be required in the following situations:


-FOR 220 VAC INPUT ADD JUMPER TO 2 & 3
REMOVE JUMPER FROM 1 & 3, 2 & 4


VIDEO Inputs: 4, 8, 12, or 40 as indicated by the last two digits of the model number.
Audio Connectors:
AF Switchers 1/8-inch RCA phone jack BAF Switchers Terminal block
Termination:
Terminated or Non-looping Switchers
Input 75-ohm internal termination Output 75-ohm source termination Looping Switchers
Input High impedance looping Output High impedance looping
ELECTRICAL (Models MS500G, MS500GL, MS540DT, and MS540LDT)
(Models MS540DT and MS540LDT Only)
Output Amplifier: One amplified output and one non-amplified output for use with MPT9000CZ/MPT9000PZ (Coaxitron® System).

Construction:
Cover Steel, black polyester powder coat Chassis Steel, zinc plated Panel Aluminum, black polyester powder coat
MS504 Series (except AFL, BAF, and BAF models): 1.75 (H) x 5.3 (W) x 9.3 (L) inches (4.45 cm x 13.46 cm x 23.62 cm)
MS504AFL, MS504BAF, MS504BAFL, and MS508 Series (except AFL model): 1.75 (H) x 14.3 (W) x 9.3 (L) inches (4.45 cm x 36.32 cm x 23.62 cm)
MS508AFL, MS512 Series, MS518 Series, and MS540DT (except MS518AFL and MS540LDT): 1.75 (H) x 17.12 (W) x 9.3 (L) inches (4.45 cm x 43.48 cm x 23.62 cm)
MS518AFL and MS540LDT: 3.50 (H) x 17.12 (W) x 9.3 (L) inches (8.89 cm x 43.48 cm x 23.62 cm)
(Design and product specifications subject to change without notice.)
Dimensions

WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: 1. Model and serial number 2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number 3. Details of the defect or problem
Exceptions to this warranty are as noted below:
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.
Manual # Date Comments C820M 3/88 Original version. C820M-A 9/90 Added to Warning Section for UL compliance. C820M-B 6/92 Revised to cover all MS500 Series models. Added DT200 to Options section. C820M-C 10/97 Revised Figures 1 and 2. Put into new format. C820M-D 1/01 Added illustrations for terminated and looping configurations with a Coaxitron transmitter. Updated manual to new format.
® Pelco, the Pelco logo, Spectra, Genex, Legacy, Coaxitron, and PelcoVision are registered trademarks of Pelco. © Copyright 2001, Pelco. ™ Esprit and Camclosure are trademarks of Pelco. All rights reserved.