LP225 RS-232 Command Values
To control one of the above noted projectors from an RS-232 control system, connect the serial cable or a null modem cable and the InFocus RS-232 Adapter (SP-CWRS232) and set the control system serial port settings to match the following communication configuration*:

RS-232 Connection for LP225
The RS-232/serial connection for these projectors is located on the PC side of the CableWizard II connection hub. Use the serial cable (IFS part # 210-0107-xx) to connect the CableWizard II to the serial port of the computer source.
All commands consist of 3 alpha characters followed by a request, all enclosed in parentheses. The request can be a read request (indicated by a "?") or a write request (indicated by 1 to 4 ASCII digits).
A read request example:
( starts the command
AAA denotes the command
? denotes the read request
) ends the command
A read command returns the range and the current setting, for example:

Communication Configuration · Command Format · (AAA?) where

A write request example:
( starts the command
AAA denotes the command
#### denotes the value to be written
(leading zeros not necessary)
) ends the command
Some commands have ranges, while others are absolute. If a number greater than the maximum range is received, it is automatically set to the maximum number for that function. If a command is received that is not understood, a "?" is returned. With absolute settings, "0" is off, 1-9999 is on. The one exception is the Power command, where 0 is off and 1 is on.
To assure the projector can process a command, wait 3 seconds before entering the next command.

Not all commands are supported for all projectors. If an unsupported command is issued, the command will be ignored. If a command is received that is not understood, a ‘?’ character will be returned indicating the command was not understood.
The CLI cannot respond to commands coming in at a high-rate. Therefore, a delay must occur between commands to ensure that the command gets properly executed. To assure the projector can process a command, wait 3 seconds before entering the next command.
(AAA####) where · Error Conditions · Limitations

Note: Specified commands and values apply to the LP225 with version 1.10 software or higher. The version number of the software is the first number listed in the upper right corner of the on-screen menu. Command values for LP225s with earlier software versions may vary. If your LP225 does not have version 1.10 software or higher, go to the Software/Downloads page to download and upgrade the projector software.
For absolute command value ranges of 0 - 1, 0 = "Off" and 1-9999 = "On" unless otherwise noted.



Owners and our team usually reply within a day — and your question helps the next person too.