The following signals are used for initial settings. The signal timing for some computer models may be different. In this case, adjust the V POSITION and H POSITION in the IMAGE menu.
Back porch (B) Front porch (D) Back porch (b) Front porch (d) Display time (C) Display time (c) Data Data H. Sync. V. Sync.
Initial set signals


15 14 13 12 11
10 9 8 7 6
5 4 3 2 1

RCA port x3 • System: 480i@60, 480p@60, 576i@50, 576p@50, 720p@50/60, 1080i@50/60, 1080p@50/60


Connection to the ports (continued)


Ø3.5 stereo mini port • Connect to the projector's remote control.
5 4 3 2 1
9 8 7 6


Connection to the ports (continued)
HDMI DVI-D CONTROL IN CONTROL OUT REMOTE
LAN
MONITOR OUT
CONTROL IN
S-VIDEO
OUT
COMPUTER IN2 COMPUTER IN1
VIDEO 1 BNC
R/Cr/Pr G/Y B/Cb/Pb H V VIDEO 2
I O
AC IN
O HDMI • Type :Digital video connector
18 16 14 12 10 8 6 4 2
19 17 15 13 11 9 7 5 3 1
RJ-45 port
8 7 6 5 4 3 2 1
Cb/Pb · Cr/Pr

This projector is equipped with PJLinkTM Class 1 protocol. Refer to the following table to control the projector using PJLinkTM protocol commands.
PJLink command

PJLink command (continued)


1 2 3 4 5 6 7 8 9
CONTROL port RS-232C cable (Cross) RS-232C port of the projector of the computer - (1) (1) CD RD (2) (2) RD TD (3) (3) TD - (4) (4) DTR GND (5) (5) GND - (6) (6) DSR RTS (7) (7) RTS CTS (8) (8) DTS - (9) (9) RI Connecting the cable 1. Turn off the projector and the computer.
Communications setting 19200bps, 8N1 1. Protocol Consist of header (7 bytes) + command data (6 bytes). 2. Header BE + EF + 03 + 06 + 00 + CRC_low + CRC_high CRC_low : Lower byte of CRC flag for command data CRC_high : Upper byte of CRC flag for command data 3. Command data Command data chart


Requesting projector status (Get command) (1) Send the request code Header + Command data (‘02H’+‘00H’+ type (2
bytes)+‘00H’ +‘00H’) from the computer to the projector. (2) The projector returns the response code ‘1DH’+ data (2 bytes) to the computer. Changing the projector settings (Set command) (1) Send the setting code Header + Command data (‘01H’+‘00H’+ type (2 bytes) +
setting code (2 bytes)) from the computer to the projector. (2) The projector changes the setting based on the above setting code. (3) The projector returns the response code ‘06H’ to the computer. Using the projector default settings (Reset Command) (1) The computer sends the default setting code Header + Command data
(‘06H’+‘00H’ + type (2 bytes) +‘00H’+‘00H’) to the projector. (2) The projector changes the specified setting to the default value. (3) The projector returns the response code ‘06H’ to the computer. Increasing the projector setting value (Increment command) (1) The computer sends the increment code Header + Command data
(‘04H’+‘00H’+ type (2 bytes) +‘00H’+‘00H’) to the projector. (2) The projector in creases the setting value on the above setting code. (3) The projector returns the response code ‘06H’ to the computer. Decreasing the projector setting value (Decrement command) (1) The computer sends the decrement code Header + Command data
(‘05H’+‘00H’+ type (2 bytes) +‘00H’ + ‘00H’) to the projector. (2) The projector decreases the setting value on the above setting code. (3) The projector returns the response code ‘06H’ to the computer. When the projector cannot understand the received command When the projector cannot understand the received command, the error code ‘15H’ is sent back to the computer. Sometimes the projector cannot properly receive the command. In this case, the command is not executed and the error code ‘15H’ is sent back to the computer. If this error code is returned, send the same command again. When the projector cannot execute the received command. When the projector cannot execute the received command, the error code ‘1CH’ + ‘xxxxH’ is sent back to the computer. When the data length is greater than indicated by the data length code, the projector will ignore the excess data code. Conversely when the data length is shorter than indicated by the data length code, an error code will be returned to the computer.
RS-232C Communication (continued)

Command Control via the Network
Communication Port The following two ports are assigned for command control.
Command Control Settings Configure the following items from a web browser when command control is used.
When the authentication setting is enabled, the following settings are required.

Command Control via the Network (continued)
Command Format [TCP #23] 1. Protocol Consist of header (7 bytes) + command data (6 bytes) 2. Header BE + EF + 03 + 06 + 00 + CRC_low + CRC_high CRC_low: Lower byte of CRC flag for command data CRC_high: Upper byte of CRC flag for command data 3. Command data Command data chart
Requesting projector status (Get command) (1) Send the following request code from the PC to the projector. Header + Command data (‘02H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’) (2) The projector returns the response code ‘1DH’ + data (2 bytes) to the PC. Changing the projector settings (Set command) (1) Send the following setting code from the PC to the projector. Header + Command data (‘01H’ + ‘00H’ + type (2 bytes) + setting code (2 bytes)) (2) The projector changes the setting based on the above setting code. (3) The projector returns the response code ‘06H’ to the PC. Using the projector default settings (Reset Command) (1) The PC sends the following default setting code to the projector. Header + Command data (‘06H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’) (2) The projector changes the specified setting to the default value. (3) The projector returns the response code ‘06H’ to the PC. Increasing the projector setting value (Increment command) (1) The PC sends the following increment code to the projector. Header + Command data (‘04H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’) (2) The projector increases the setting value on the above setting code. (3) The projector returns the response code ‘06H’ to the PC.

Command Control via the Network (continued)
Decreasing the projector setting value (Decrement command) (1) The PC sends the following decrement code to the projector. Header + Command data (‘05H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’) (2) The projector decreases the setting value on the above setting code. (3) The projector returns the response code ‘06H’ to the PC. When the projector cannot understand the received command When the projector cannot understand the received command, the error code ‘15H’ is sent back to the PC. Sometimes the projector cannot properly receive the command. In this case, the command is not executed and the error code ‘15H’ is sent back to the PC. If this error code is returned, send the same command again. When the projector cannot execute the received command. When the projector cannot execute the received command, the error code ‘1CH’ + ‘xxxxH’ is sent back to the PC. When the data length is greater than indicated by the data length code, the projector will ignore the excess data code. Conversely when the data length is shorter than indicated by the data length code, an error code will be returned to the PC. When authentication error occurred. When authentication error occurred, the error code the ‘1FH’ + ‘0400H’ is sent back to the PC.
[TCP #9715] 1. Protocol Consist of header (1 byte) + data length (1 byte) + command data (13 bytes) + check sum (1 bytes) + connection ID (1 byte). 2. Header 02, Fixed 3. Data Length Network control commands byte length (0D, Fixed) 4. Command data Network control commands that start with BE EF (13bytes). 5. Check Sum This is the value to make zero on the addition of the lower 8 bits from the header to the checksum. 6. Connection ID Random value from 0 to 255 (This value is attached to the reply data).

Command Control via the Network (continued)
ACK reply: ‘06H’ + ‘xxH’ NAK reply: ‘15H’ + ‘xxH’ Error reply: ‘1CH’ + ‘xxxxH’ + ‘xxH’ Data reply: ‘1DH’ + ‘xxxxH’ + ‘xxH’ Projector busy reply: ‘1FH’ + ‘xxxxH’ + ‘xxH’ Authentication error reply: ‘1FH’ + ‘0400H’ + ‘xxH’ (‘xxH’: connection ID)
Automatic Connection Break The TCP connection will be automatically disconnected after there is no communication for 30 seconds after being established.
Authentication The projector does not accept commands without authentication success when authentication is enabled. The projector uses a challenge response type authentication with an MD5 (Message Digest 5) algorithm. When the projector is using a LAN, a random 8 bytes will be returned if authentication is enabled. Combine this received 8 bytes and the authentication password and digest this data with the MD5 algorithm and add this in front of the commands to send.
Following is a sample if the authentication password is set to “password” and the random 8 bytes are “a572f60c”.
1) Select the projector. 2) Receive the random 8 bytes “a572f60c” from the projector. 3) Combine the random 8 bytes “a572f60c” and the authentication password “password” and it becomes “a572f60cpassword”. 4) Use this combination “a572f60cpassword” with MD5 algorithm. It will become “e3d97429adffa11bce1f7275813d4bde”. 5) Add “e3d97429adffa11bce1f7275813d4bde” in front of the commands and send the data. Send “e3d97429adffa11bce1f7275813d4bde”+command. 6) When the sending data is correct, the command will be performed and the reply data will be returned. Otherwise, an authentication error will be returned.

1 2 3 4 5 6 7 8 9
1 2 3 4 5
6 7 8 9
CONTROL IN port in Projector RS-232C cable (Cross)
- (1) (1) CD RD (2) (2) RD TD (3) (3) TD - (4) (4) DTR GND (5) (5) GND - (6) (6) DSR RTS (7) (7) RTS CTS (8) (8) DTS - (9) (9) RI
1.Communications setting Set the same communication settings (selecting from options below) on the CONTROL terminal for transmitting and receiving side connected with a RS-232C cable.
Baud rate: 4800 / 9600 / 19200 / 38400 bps Parity NONE / ODD / EVEN Data bit: 8 bit (fixed) Start bit: 1 bit (fixed) Stop bit: 1 bit (fixed) 2.Commands available only for daisy chain communication The projector supports the following commands only for daisy chain. (1) Control the projector (Set/Increment/Decrement/Execute) (2) Get the projector’s status (Get) (3) Get the number of connected projectors (4) Set the communication Group identification and Communication ID. (5) Get the communication Group identification and Communication ID. 3.Command format Protocol Consist of header data (7 bytes) + command data (6 bytes) Header BE + EF + Packet_Type + 06 + Group + ID + Checksum Data chart

Support Command Packet_Type Group ID Control the projector ‘83H’ 0~16 0~64 Get the projector’s status ‘83H’ 1~16 1~64 Get the number of connected projectors ‘84H’ 0 0 Set the communication Group identification and Communication ID
Daisy Chain Communication

Calculation of Checksum Sum up all of 12 bytes except the Checksum, then make the bit inversion of the lowest byte of the total, and add 1 to the inverted byte. The calculated result is the Checksum data.
Data Size Group ID Checksum Action Type Setting
Code BE EF 83 06 01 01 66 01 00 00 60 01 00
BE + EF + 83 + 06 + 01 + 01 + 01 + 00 + 00 + 60 + 01 + 00 = ‘029AH’
The lowest byte of ‘029AH’ is ‘9AH’ (1001 1010). Making the bit inversion of the ‘9AH’ gets ‘65H’ (0110 0101), then, add 1. The calculated checksum is ’66H’. Group and ID Settings This daisy chain command can adjust the control range by using the Group identification and ID.

Group ID Direction note 1~16 1~64 Individual control The command is available to the projectors with the same Group identification and ID numbers and command setting. 1~16 0 Designated control according to the Group identification
The command is available to the projectors with the same Group identification and command setting.
The command is available to the projectors with the same ID number and command setting. 0 0 Unlimited. The command is available to the all projectors.
Daisy Chain Communication

byte_0 byte_1 byte_2 byte_3 byte_4 byte_5 Action Type Setting Code low high low high low high
Action Classification Content 1 Set Change setting to desired value. 4 Increment Increment setup value by 1. 5 Decrement Decrement setup value by 1. 6 Execute Run a command. Note: For the Type and Setting Code, see the RS-232C communication/ Network command table (20).

byte_0 byte_1 byte_2 byte_3 byte_4 byte_5 Action Type Connection ID low high low high low high Action (byte_0-1)
Action Classification Content 2 Get Read projector internal setup value.
Connection ID Content 0~255 This value is attached to the reply data. ③Other commands
byte_0 byte_1 byte_2 byte_3 byte_4 byte_5 Action Target Number Connection ID low high low high low high

Support Command Action Target Number Connection ID Get the number of connected projectors 2 0 0~255 Set the communication Group identification and Communication ID
Daisy Chain Communication

Command data Requesting projector status (Get command) (1) Send the following request code from the PC to the projector.
Header + Command data (‘02H’ + ‘00H’ + type (2 bytes) + connection ID (2 bytes)) (2) The projector returns the response code to the PC.
‘9DH’ + ‘02H’ + connection ID (2 bytes) + data (2 bytes) When the projector cannot understand the received command, the error code is sent back to the PC. ‘95H’ + ‘02H’ + connection ID (2 bytes) + ‘00H’ + ‘00H’ When the projector cannot execute the received command, the error code is sent back to the PC. ‘9CH’ + ‘02H’ + connection ID (2 bytes) + error code (2 bytes) Action (byte_0-1)
Error Code Content 0 The command was not accepted because the projector connected to PC was busy. 1 Communication error occurred between projectors. 2 The command was not accepted because the designated projector was not found. Changing the projector settings (Set command) (1) Send the following request code from the PC to the projector. Header + Command data (‘01H’ + ‘00H’ + type (2 bytes) + setting code (2 bytes)) (2) The projector changes the setting based on the above setting code. (3) Projector does not send out the response data.
Using the projector default settings (Reset Command) (1) The PC sends the following default setting code to the projector. Header + Command data (‘06H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’) (2) The projector changes the specified setting to the default value. (3) Projector does not send out the response data.
Increasing the projector setting value (Increment command) (1) The PC sends the following increment code to the projector. Header + Command data (‘04H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’) (2) The projector increases the setting value on the above setting code. (3) Projector does not send out the response data.
Decreasing the projector setting value (Decrement command) (1) The PC sends the following decrement code to the projector. Header + Command data (‘05H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’) (2) The projector decreases the setting value on the above setting code. (3) Projector does not send out the response data.
Daisy Chain Communication

Get the number of connected projectors (1) Send the following request code from the PC to the projector. Header + Command data (‘02H’ + ‘00H’ + ‘00H’ + ‘00H’ + connection ID (2 bytes)) (2) The projector returns the response code to the PC. ‘9EH’ + ‘04H’ + connection ID (2 bytes) + number of projectors (2 bytes) + group (1 byte) + ID (1 byte) When the projector cannot understand the received command, the error code is sent back to the PC. ‘96H’ + ‘04H’ + connection ID (2 bytes) + ‘00H’ + ‘00H’ + ‘00H’ + ‘00H’ When the projector cannot execute the received command, the error code is sent back to the PC. ‘9FH’ + ‘06H’ + connection ID (2 bytes) + position number of projector having an error* (2 bytes) + group (1 byte) + ID (1 byte) + error code (2 bytes) *The position number is counted from the projector connected to PC directly, which has No.1 as position number. Then, the next one is No.2 and so on. Error Code
Error Code Content 0 The command was not accepted because the projector connected to PC
was busy. 1 Communication error occurred between projectors. Set the communication Group identification and Communication ID (1) Send the following setting code from the PC to the projector. Header + Command data (‘01H’ + ‘00H’ + target number (2 bytes) + connection ID (2 bytes)) (2) The projector changes the group and ID setting based on the above setting code. (3) Projector does not send out the response data.
Daisy Chain Communication

Get the communication Group identification and Communication ID (1) Send the following request code from the PC to the projector. Header + Command data (‘02H’ + ‘00H’ + target number (2 bytes) + connection ID (2 bytes)) (2) The projector returns the response code to the PC. ‘90H’ + ‘04H’ + connection ID (2 bytes) + target number (2 bytes) + group (1 byte) + ID (1 byte) When the projector cannot understand the received command, the error code is sent back to the PC. ‘97H’ + ‘04H’ + connection ID (2 bytes) + ‘00H’ + ‘00H’ + ‘00H’ + ‘00H’ When the projector cannot execute the received command, the error code is sent back to the PC. ‘91H’ + ‘06H’ + connection ID (2 bytes) + position number of projector having an error* (2 bytes) + group (1 byte) + ID (1 byte) + error code (2 bytes) * The position number is counted from the projector connected to PC directly, which has No.1 as position number. Then, the next one is No.2 and so on. Error Code
Error Code Content 0 The command was not accepted because the projector connected to PC was busy. 1 Communication error occurred between projectors. 2 The command was not accepted because the designated projector was not found.
Daisy Chain Communication

Names Operation Type Header Command Data CRC Action Type Setting Code
Power Set OFF BE EF 03 06 00 2A D3 01 00 00 60 00 00 ON BE EF 03 06 00 BA D2 01 00 00 60 01 00 Get BE EF 03 06 00 19 D3 02 00 00 60 00 00 (Example Return) 00 00 01 00 02 00 (Off) (On) (Cool Down) Input Source Set COMPUTER IN 1 BE EF 03 06 00 FE D2 01 00 00 20 00 00 COMPUTER IN 2 BE EF 03 06 00 3E D0 01 00 00 20 04 00 HDMI BE EF 03 06 00 0E D2 01 00 00 20 03 00 VIDEO 1 BE EF 03 06 00 6E D3 01 00 00 20 01 00 S-VIDEO BE EF 03 06 00 9E D3 01 00 00 20 02 00 COMPONENT BE EF 03 06 00 AE D1 01 00 00 20 05 00 BNC BE EF 03 06 00 CE D0 01 00 00 20 07 00 DVI-D BE EF 03 06 00 AE D4 01 00 00 20 09 00 VIDEO 2 BE EF 03 06 00 5E D4 01 00 00 20 0A 00 Get BE EF 03 06 00 CD D2 02 00 00 20 00 00 Error Status Get BE EF 03 06 00 D9 D8 02 00 20 60 00 00 (Example Return)
00 00 01 00 02 00 03 00 (Normal) (Cover error) (Fan error) (Lamp error) 04 00 05 00 (Temp error) (Air flow error) 07 00 08 00 0F 00 10 00 (Cold error) (Filter error) (Shutter error) (Lens Shift error) BRIGHTNESS Get BE EF 03 06 00 89 D2 02 00 03 20 00 00 Increment BE EF 03 06 00 EF D2 04 00 03 20 00 00 Decrement BE EF 03 06 00 3E D3 05 00 03 20 00 00 CONTRAST Get BE EF 03 06 00 FD D3 02 00 04 20 00 00 Increment BE EF 03 06 00 9B D3 04 00 04 20 00 00 Decrement BE EF 03 06 00 4A D2 05 00 04 20 00 00 PICTURE MODE Set NORMAL BE EF 03 06 00 23 F6 01 00 BA 30 00 00 CINEMA BE EF 03 06 00 B3 F7 01 00 BA 30 01 00 DYNAMIC BE EF 03 06 00 E3 F4 01 00 BA 30 04 00 BOARD (BLACK) BE EF 03 06 00 E3 EF 01 00 BA 30 20 00 BOARD (GREEN) BE EF 03 06 00 73 EE 01 00 BA 30 21 00 WHITE BOARD BE EF 03 06 00 83 EE 01 00 BA 30 22 00 DAY TIME BE EF 03 06 00 E3 C7 01 00 BA 30 40 00 CUSTOM BE EF 03 06 00 E3 FB 01 00 BA 30 10 00 Get BE EF 03 06 00 10 F6 02 00 BA 30 00 00 GAMMA Set 1 DEFAULT BE EF 03 06 00 07 E9 01 00 A1 30 20 00
2 DEFAULT BE EF 03 06 00 97 E8 01 00 A1 30 21 00 3 DEFAULT BE EF 03 06 00 67 E8 01 00 A1 30 22 00 4 DEFAULT BE EF 03 06 00 F7 E9 01 00 A1 30 23 00 5 DEFAULT BE EF 03 06 00 C7 EB 01 00 A1 30 24 00 6 DEFAULT BE EF 03 06 00 57 EA 01 00 A1 30 25 00 1 CUSTOM BE EF 03 06 00 07 FD 01 00 A1 30 10 00 2 CUSTOM BE EF 03 06 00 97 FC 01 00 A1 30 11 00 3 CUSTOM BE EF 03 06 00 67 FC 01 00 A1 30 12 00 4 CUSTOM BE EF 03 06 00 F7 FD 01 00 A1 30 13 00

Names Operation Type Header Command Data CRC Action Type Setting Code
GAMMA Set 5 CUSTOM BE EF 03 06 00 C7 FF 01 00 A1 30 14 00 6 CUSTOM BE EF 03 06 00 57 FE 01 00 A1 30 15 00 Get BE EF 03 06 00 F4 F0 02 00 A1 30 00 00 User Gamma Pattern Set Off BE EF 03 06 00 FB FA 01 00 80 30 00 00 9step Gray Scale BE EF 03 06 00 6B FB 01 00 80 30 01 00 15step Gray Scale BE EF 03 06 00 9B FB 01 00 80 30 02 00 Ramp BE EF 03 06 00 0B FA 01 00 80 30 03 00 Get BE EF 03 06 00 C8 FA 02 00 80 30 00 00 User Gamma Point 1 Get BE EF 03 06 00 08 FE 02 00 90 30 00 00 Increment BE EF 03 06 00 6E FE 04 00 90 30 00 00 Decrement BE EF 03 06 00 BF FF 05 00 90 30 00 00 User Gamma Point 2 Get BE EF 03 06 00 F4 FF 02 00 91 30 00 00 Increment BE EF 03 06 00 92 FF 04 00 91 30 00 00 Decrement BE EF 03 06 00 43 FE 05 00 91 30 00 00 User Gamma Point 3 Get BE EF 03 06 00 B0 FF 02 00 92 30 00 00 Increment BE EF 03 06 00 D6 FF 04 00 92 30 00 00 Decrement BE EF 03 06 00 07 FE 05 00 92 30 00 00 User Gamma Point 4 Get BE EF 03 06 00 4C FE 02 00 93 30 00 00 Increment BE EF 03 06 00 2A FE 04 00 93 30 00 00 Decrement BE EF 03 06 00 FB FF 05 00 93 30 00 00 User Gamma Point 5 Get BE EF 03 06 00 38 FF 02 00 94 30 00 00 Increment BE EF 03 06 00 5E FF 04 00 94 30 00 00 Decrement BE EF 03 06 00 8F FE 05 00 94 30 00 00 User Gamma Point 6 Get BE EF 03 06 00 C4 FE 02 00 95 30 00 00 Increment BE EF 03 06 00 A2 FE 04 00 95 30 00 00 Decrement BE EF 03 06 00 73 FF 05 00 95 30 00 00 User Gamma Point 7 Get BE EF 03 06 00 80 FE 02 00 96 30 00 00 Increment BE EF 03 06 00 E6 FE 04 00 96 30 00 00 Decrement BE EF 03 06 00 37 FF 05 00 96 30 00 00 User Gamma Point 8 Get BE EF 03 06 00 7C FF 02 00 97 30 00 00
Increment BE EF 03 06 00 1A FF 04 00 97 30 00 00 Decrement BE EF 03 06 00 CB FE 05 00 97 30 00 00 COLOR TEMP Set 1 HIGH BE EF 03 06 00 0B F5 01 00 B0 30 03 00 2 MID BE EF 03 06 00 9B F4 01 00 B0 30 02 00 3 LOW BE EF 03 06 00 6B F4 01 00 B0 30 01 00 4 Hi-BRIGHT-1 BE EF 03 06 00 3B F2 01 00 B0 30 08 00 5 Hi-BRIGHT-2 BE EF 03 06 00 AB F3 01 00 B0 30 09 00 6 Hi-BRIGHT-3 BE EF 03 06 00 5B F3 01 00 B0 30 0A 00 1 CUSTOM (HIGH) BE EF 03 06 00 CB F8 01 00 B0 30 13 00 2 CUSTOM (MID) BE EF 03 06 00 5B F9 01 00 B0 30 12 00 3 CUSTOM (LOW) BE EF 03 06 00 AB F9 01 00 B0 30 11 00 4 CUSTOM (Hi-BRIGHT-1)
BE EF 03 06 00 FB FF 01 00 B0 30 18 00
BE EF 03 06 00 6B FE 01 00 B0 30 19 00
BE EF 03 06 00 9B FE 01 00 B0 30 1A 00
Get BE EF 03 06 00 C8 F5 02 00 B0 30 00 00
5 CUSTOM (Hi-BRIGHT-2) · 6 CUSTOM (Hi-BRIGHT-3)

Names Operation Type Header Command Data CRC Action Type Setting Code
COLOR TEMP GAIN R Get BE EF 03 06 00 34 F4 02 00 B1 30 00 00 Increment BE EF 03 06 00 52 F4 04 00 B1 30 00 00 Decrement BE EF 03 06 00 83 F5 05 00 B1 30 00 00 COLOR TEMP GAIN G Get BE EF 03 06 00 70 F4 02 00 B2 30 00 00 Increment BE EF 03 06 00 16 F4 04 00 B2 30 00 00 Decrement BE EF 03 06 00 C7 F5 05 00 B2 30 00 00 COLOR TEMP GAIN B Get BE EF 03 06 00 8C F5 02 00 B3 30 00 00 Increment BE EF 03 06 00 EA F5 04 00 B3 30 00 00 Decrement BE EF 03 06 00 3B F4 05 00 B3 30 00 00 COLOR TEMP OFFSET
Get BE EF 03 06 00 04 F5 02 00 B5 30 00 00 Increment BE EF 03 06 00 62 F5 04 00 B5 30 00 00 Decrement BE EF 03 06 00 B3 F4 05 00 B5 30 00 00 COLOR TEMP OFFSET
Get BE EF 03 06 00 40 F5 02 00 B6 30 00 00 Increment BE EF 03 06 00 26 F5 04 00 B6 30 00 00 Decrement BE EF 03 06 00 F7 F4 05 00 B6 30 00 00 COLOR TEMP OFFSET
Get BE EF 03 06 00 BC F4 02 00 B7 30 00 00 Increment BE EF 03 06 00 DA F4 04 00 B7 30 00 00 Decrement BE EF 03 06 00 0B F5 05 00 B7 30 00 00 COLOR Get BE EF 03 06 00 B5 72 02 00 02 22 00 00 Increment BE EF 03 06 00 D3 72 04 00 02 22 00 00 Decrement BE EF 03 06 00 02 73 05 00 02 22 00 00 COLOR Reset Execute BE EF 03 06 00 80 D0 06 00 0A 70 00 00 TINT Get BE EF 03 06 00 49 73 02 00 03 22 00 00 Increment BE EF 03 06 00 2F 73 04 00 03 22 00 00 Decrement BE EF 03 06 00 FE 72 05 00 03 22 00 00 TINT Reset Execute BE EF 03 06 00 7C D1 06 00 0B 70 00 00 SHARPNESS Get BE EF 03 06 00 F1 72 02 00 01 22 00 00
Increment BE EF 03 06 00 97 72 04 00 01 22 00 00 Decrement BE EF 03 06 00 46 73 05 00 01 22 00 00 SHARPNESS Reset Execute BE EF 03 06 00 C4 D0 06 00 09 70 00 00 ACTIVE IRIS Set PRESENTATION BE EF 03 06 00 5B 2E 01 00 04 33 11 00 THEATER BE EF 03 06 00 CB 2F 01 00 04 33 10 00 MANUAL BE EF 03 06 00 CB 3B 01 00 04 33 20 00 Get BE EF 03 06 00 38 22 02 00 04 33 00 00 MANUAL IRIS Get BE EF 03 06 00 B0 22 02 00 02 33 00 00 Increment BE EF 03 06 00 D6 22 04 00 02 33 00 00 Decrement BE EF 03 06 00 07 23 05 00 02 33 00 00 MY MEMORY Load Set 1 BE EF 03 06 00 0E D7 01 00 14 20 00 00 2 BE EF 03 06 00 9E D6 01 00 14 20 01 00 3 BE EF 03 06 00 6E D6 01 00 14 20 02 00 4 BE EF 03 06 00 FE D7 01 00 14 20 03 00 MY MEMORY Save Set 1 BE EF 03 06 00 F2 D6 01 00 15 20 00 00 2 BE EF 03 06 00 62 D7 01 00 15 20 01 00 3 BE EF 03 06 00 92 D7 01 00 15 20 02 00 4 BE EF 03 06 00 02 D6 01 00 15 20 03 00 PROGRESSIVE Set OFF BE EF 03 06 00 4A 72 01 00 07 22 00 00 TV BE EF 03 06 00 DA 73 01 00 07 22 01 00 FILM BE EF 03 06 00 2A 73 01 00 07 22 02 00 Get BE EF 03 06 00 79 72 02 00 07 22 00 00

Names Operation Type Header Command Data CRC Action Type Setting Code
3D-YCS Set OFF BE EF 03 06 00 E6 70 01 00 0A 22 00 00 MOVIE BE EF 03 06 00 76 71 01 00 0A 22 01 00 STILL IMAGE BE EF 03 06 00 86 71 01 00 0A 22 02 00 Get BE EF 03 06 00 D5 70 02 00 0A 22 00 00 VIDEO NR Set LOW BE EF 03 06 00 26 72 01 00 06 22 01 00 MID BE EF 03 06 00 D6 72 01 00 06 22 02 00 HIGH BE EF 03 06 00 46 73 01 00 06 22 03 00 Get BE EF 03 06 00 85 73 02 00 06 22 00 00 ASPECT Set NORMAL BE EF 03 06 00 5E DD 01 00 08 20 10 00 4:3 BE EF 03 06 00 9E D0 01 00 08 20 00 00 16:9 BE EF 03 06 00 0E D1 01 00 08 20 01 00 16:10 *2 BE EF 03 06 00 3E D6 01 00 08 20 0A 00 14:9 BE EF 03 06 00 CE D6 01 00 08 20 09 00 SMALL *1 BE EF 03 06 00 FE D1 01 00 08 20 02 00 NATIVE *2 BE EF 03 06 00 5E D7 01 00 08 20 08 00 FULL *2 BE EF 03 06 00 5E C9 01 00 08 20 20 00 Get BE EF 03 06 00 AD D0 02 00 08 20 00 00 OVER SCAN Get BE EF 03 06 00 91 70 02 00 09 22 00 00 Increment BE EF 03 06 00 F7 70 04 00 09 22 00 00 Decrement BE EF 03 06 00 26 71 05 00 09 22 00 00 OVER SCAN Reset Execute BE EF 03 06 00 EC D9 06 00 27 70 00 00 V POSITION Get BE EF 03 06 00 0D 83 02 00 00 21 00 00 Increment BE EF 03 06 00 6B 83 04 00 00 21 00 00 Decrement BE EF 03 06 00 BA 82 05 00 00 21 00 00 V POSITION Reset Execute BE EF 03 06 00 E0 D2 06 00 02 70 00 00 H POSITION Get BE EF 03 06 00 F1 82 02 00 01 21 00 00 Increment BE EF 03 06 00 97 82 04 00 01 21 00 00 Decrement BE EF 03 06 00 46 83 05 00 01 21 00 00
H POSITION Reset Execute BE EF 03 06 00 1C D3 06 00 03 70 00 00 H PHASE Get BE EF 03 06 00 49 83 02 00 03 21 00 00 Increment BE EF 03 06 00 2F 83 04 00 03 21 00 00 Decrement BE EF 03 06 00 FE 82 05 00 03 21 00 00 H SIZE Get BE EF 03 06 00 B5 82 02 00 02 21 00 00 Increment BE EF 03 06 00 D3 82 04 00 02 21 00 00 Decrement BE EF 03 06 00 02 83 05 00 02 21 00 00 H SIZE Reset Execute BE EF 03 06 00 68 D2 06 00 04 70 00 00 AUTO ADJUST Execute BE EF 03 06 00 91 D0 06 00 0A 20 00 00 COLOR SPACE Set AUTO BE EF 03 06 00 0E 72 01 00 04 22 00 00 RGB BE EF 03 06 00 9E 73 01 00 04 22 01 00 SMPTE240 BE EF 03 06 00 6E 73 01 00 04 22 02 00 REC709 BE EF 03 06 00 FE 72 01 00 04 22 03 00 REC601 BE EF 03 06 00 CE 70 01 00 04 22 04 00 Get BE EF 03 06 00 3D 72 02 00 04 22 00 00 COMPONENT Set COMPONENT BE EF 03 06 00 4A D7 01 00 17 20 00 00 SCART RGB BE EF 03 06 00 DA D6 01 00 17 20 01 00 Get BE EF 03 06 00 79 D7 02 00 17 20 00 00
*1 IN5542/IN5542c only. *2 IN5544/IN5544c only.

Names Operation Type Header Command Data CRC Action Type Setting Code
S-VIDEO FORMAT Set AUTO BE EF 03 06 00 E6 70 01 00 12 22 0A 00 NTSC BE EF 03 06 00 86 74 01 00 12 22 04 00 PAL BE EF 03 06 00 16 75 01 00 12 22 05 00 SECAM BE EF 03 06 00 16 70 01 00 12 22 09 00 NTSC4.43 BE EF 03 06 00 26 77 01 00 12 22 02 00 M-PAL BE EF 03 06 00 86 71 01 00 12 22 08 00 N-PAL BE EF 03 06 00 76 74 01 00 12 22 07 00 Get BE EF 03 06 00 75 76 02 00 12 22 00 00 VIDEO 1 FORMAT Set AUTO BE EF 03 06 00 A2 70 01 00 11 22 0A 00 NTSC BE EF 03 06 00 C2 74 01 00 11 22 04 00 PAL BE EF 03 06 00 52 75 01 00 11 22 05 00 SECAM BE EF 03 06 00 52 70 01 00 11 22 09 00 NTSC4.43 BE EF 03 06 00 62 77 01 00 11 22 02 00 M-PAL BE EF 03 06 00 C2 71 01 00 11 22 08 00 N-PAL BE EF 03 06 00 32 74 01 00 11 22 07 00 Get BE EF 03 06 00 31 76 02 00 11 22 00 00 VIDEO 2 FORMAT Set AUTO BE EF 03 06 00 86 72 01 00 1A 22 0A 00 NTSC BE EF 03 06 00 E6 76 01 00 1A 22 04 00 PAL BE EF 03 06 00 76 77 01 00 1A 22 05 00 SECAM BE EF 03 06 00 76 72 01 00 1A 22 09 00 NTSC4.43 BE EF 03 06 00 46 75 01 00 1A 22 02 00 M-PAL BE EF 03 06 00 E6 73 01 00 1A 22 08 00 N-PAL BE EF 03 06 00 16 76 01 00 1A 22 07 00 Get BE EF 03 06 00 15 74 02 00 1A 22 00 00 HDMI FORMAT Set AUTO BE EF 03 06 00 BA 77 01 00 13 22 00 00 VIDEO BE EF 03 06 00 2A 76 01 00 13 22 01 00 COMPUTER BE EF 03 06 00 DA 76 01 00 13 22 02 00 Get BE EF 03 06 00 89 77 02 00 13 22 00 00 DVI-D FORMAT Set AUTO BE EF 03 06 00 62 74 01 00 19 22 00 00 VIDEO BE EF 03 06 00 F2 75 01 00 19 22 01 00 COMPUTER BE EF 03 06 00 02 75 01 00 19 22 02 00
Get BE EF 03 06 00 51 74 02 00 19 22 00 00 HDMI RANGE Set AUTO BE EF 03 06 00 86 D8 01 00 22 20 00 00 NORMAL BE EF 03 06 00 16 D9 01 00 22 20 01 00 ENHANCED BE EF 03 06 00 E6 D9 01 00 22 20 02 00 Get BE EF 03 06 00 B5 D8 02 00 22 20 00 00 DVI-D RANGE Set AUTO BE EF 03 06 00 FE D4 01 00 20 20 10 00 NORMAL BE EF 03 06 00 3E D9 01 00 20 20 00 00 ENHANCED BE EF 03 06 00 AE D8 01 00 20 20 01 00 Get BE EF 03 06 00 0D D9 02 00 20 20 00 00 COMPUTER IN 1 Set SYNC ON G OFF BE EF 03 06 00 5E D7 01 00 10 20 02 00 AUTO BE EF 03 06 00 CE D6 01 00 10 20 03 00 Get BE EF 03 06 00 0D D6 02 00 10 20 00 00 COMPUTER IN 2 Set SYNC ON G OFF BE EF 03 06 00 A2 D6 01 00 11 20 02 00 AUTO BE EF 03 06 00 32 D7 01 00 11 20 03 00 Get BE EF 03 06 00 F1 D7 02 00 11 20 00 00 BNC Set SYNC ON G OFF BE EF 03 06 00 86 D4 01 00 1A 20 02 00 AUTO BE EF 03 06 00 16 D5 01 00 1A 20 03 00 Get BE EF 03 06 00 D5 D5 02 00 1A 20 00 00

Names Operation Type Header Command Data CRC Action Type Setting Code
Set OFF BE EF 03 06 00 3B C2 01 00 50 30 00 00 ON BE EF 03 06 00 AB C3 01 00 50 30 01 00 Get BE EF 03 06 00 08 C2 02 00 50 30 00 00 FRAME LOCK - COMPUTER IN 2
Set OFF BE EF 03 06 00 0B C3 01 00 54 30 00 00 ON BE EF 03 06 00 9B C2 01 00 54 30 00 00 Get BE EF 03 06 00 38 C3 02 00 54 30 00 00 FRAME LOCK - BNC Set OFF BE EF 03 06 00 4F C3 01 00 57 30 00 00 ON BE EF 03 06 00 DF C2 01 00 57 30 01 00 Get BE EF 03 06 00 7C C3 02 00 57 30 00 00 FRAME LOCK - HDMI Set OFF BE EF 03 06 00 7F C2 01 00 53 30 00 00 ON BE EF 03 06 00 EF C3 01 00 53 30 01 00 Get BE EF 03 06 00 4C C2 02 00 53 30 00 00 FRAME LOCK - DVI-D Set OFF BE EF 03 06 00 A7 C1 01 00 59 30 00 00 ON BE EF 03 06 00 37 C0 01 00 59 30 01 00 Get BE EF 03 06 00 94 C1 02 00 59 30 00 00 KEYSTONE V Get BE EF 03 06 00 B9 D3 02 00 07 20 00 00 Increment BE EF 03 06 00 DF D3 04 00 07 20 00 00 Decrement BE EF 03 06 00 0E D2 05 00 07 20 00 00 KEYSTONE V Reset Execute BE EF 03 06 00 08 D0 06 00 0C 70 00 00 AUTO KEYSTONE V
Execute BE EF 03 06 00 E5 D1 06 00 0D 20 00 00
AUTO KEYSTONE V Set OFF BE EF 03 06 00 EA D1 01 00 0F 20 00 00 ON BE EF 03 06 00 7A D0 01 00 0F 20 01 00 Get BE EF 03 06 00 D9 D1 02 00 0F 20 00 00 KEYSTONE H Get BE EF 03 06 00 E9 D0 02 00 0B 20 00 00 Increment BE EF 03 06 00 8F D0 04 00 0B 20 00 00 Decrement BE EF 03 06 00 5E D1 05 00 0B 20 00 00 KEYSTONE H Reset Execute BE EF 03 06 00 98 D8 06 00 20 70 00 00 ECO MODE Set NORMAL BE EF 03 06 00 3B 23 01 00 00 33 00 00 ECO BE EF 03 06 00 AB 22 01 00 00 33 01 00 Get BE EF 03 06 00 08 23 02 00 00 33 00 00 MIRROR Set NORMAL BE EF 03 06 00 C7 D2 01 00 01 30 00 00
H:INVERT BE EF 03 06 00 57 D3 01 00 01 30 01 00 V:INVERT BE EF 03 06 00 A7 D3 01 00 01 30 02 00 H&V:INVERT BE EF 03 06 00 37 D2 01 00 01 30 03 00 Get BE EF 03 06 00 F4 D2 02 00 01 30 00 00 MONITOR OUT - COMPUTER IN 1
Set COMPUTER IN 1 BE EF 03 06 00 3E F4 01 00 B0 20 00 00 COMPUTER IN 2 BE EF 03 06 00 FE F6 01 00 B0 20 04 00 BNC BE EF 03 06 00 0E F6 01 00 B0 20 07 00 OFF BE EF 03 06 00 CE B5 01 00 B0 20 FF 00 Get BE EF 03 06 00 0D F4 02 00 B0 20 00 00 MONITOR OUT - COMPUTER IN 2
Set COMPUTER IN 1 BE EF 03 06 00 0E F5 01 00 B4 20 00 00 COMPUTER IN 2 BE EF 03 06 00 CE F7 01 00 B4 20 04 00 BNC BE EF 03 06 00 3E F7 01 00 B4 20 07 00 OFF BE EF 03 06 00 FE B4 01 00 B4 20 FF 00 Get BE EF 03 06 00 3D F5 02 00 B4 20 00 00 MONITOR OUT -
Set COMPUTER IN 1 BE EF 03 06 00 4A F5 01 00 B7 20 00 00 COMPUTER IN 2 BE EF 03 06 00 8A F7 01 00 B7 20 04 00 BNC BE EF 03 06 00 7A F7 01 00 B7 20 07 00 OFF BE EF 03 06 00 BA B4 01 00 B7 20 FF 00 Get BE EF 03 06 00 79 F5 02 00 B7 20 00 00

Names Operation Type Header Command Data CRC Action Type Setting Code
Set COMPUTER IN 1 BE EF 03 06 00 7A F4 01 00 B3 20 00 00 COMPUTER IN 2 BE EF 03 06 00 BA F6 01 00 B3 20 04 00 BNC BE EF 03 06 00 4A F6 01 00 B3 20 07 00 OFF BE EF 03 06 00 8A B5 01 00 B3 20 FF 00 Get BE EF 03 06 00 49 F4 02 00 B3 20 00 00 MONITOR OUT -
Set COMPUTER IN 1 BE EF 03 06 00 A2 F7 01 00 B9 20 00 00 COMPUTER IN 2 BE EF 03 06 00 62 F5 01 00 B9 20 04 00 BNC BE EF 03 06 00 92 F5 01 00 B9 20 07 00 OFF BE EF 03 06 00 52 B6 01 00 B9 20 FF 00 Get BE EF 03 06 00 91 F7 02 00 B9 20 00 00 MONITOR OUT -
Set COMPUTER IN 1 BE EF 03 06 00 F2 F4 01 00 B5 20 00 00 COMPUTER IN 2 BE EF 03 06 00 32 F6 01 00 B5 20 04 00 BNC BE EF 03 06 00 C2 F6 01 00 B5 20 07 00 OFF BE EF 03 06 00 02 B5 01 00 B5 20 FF 00 Get BE EF 03 06 00 C1 F4 02 00 B5 20 00 00 MONITOR OUT -
Set COMPUTER IN 1 BE EF 03 06 00 86 F5 01 00 B2 20 00 00 COMPUTER IN 2 BE EF 03 06 00 46 F7 01 00 B2 20 04 00 BNC BE EF 03 06 00 B6 F7 01 00 B2 20 07 00 OFF BE EF 03 06 00 76 B4 01 00 B2 20 FF 00 Get BE EF 03 06 00 B5 F5 02 00 B2 20 00 00 MONITOR OUT -
Set COMPUTER IN 1 BE EF 03 06 00 C2 F5 01 00 B1 20 00 00 COMPUTER IN 2 BE EF 03 06 00 02 F7 01 00 B1 20 04 00 BNC BE EF 03 06 00 F2 F7 01 00 B1 20 07 00 OFF BE EF 03 06 00 32 B4 01 00 B1 20 FF 00 Get BE EF 03 06 00 F1 F5 02 00 B1 20 00 00
MONITOR OUT -
Set COMPUTER IN 1 BE EF 03 06 00 E6 F7 01 00 BA 20 00 00 COMPUTER IN 2 BE EF 03 06 00 26 F5 01 00 BA 20 04 00 BNC BE EF 03 06 00 D6 F5 01 00 BA 20 07 00 OFF BE EF 03 06 00 16 B6 01 00 BA 20 FF 00 Get BE EF 03 06 00 D5 F7 02 00 BA 20 00 00 MONITOR OUT -
Set COMPUTER IN 1 BE EF 03 06 00 2A F7 01 00 BF 20 00 00 COMPUTER IN 2 BE EF 03 06 00 EA F5 01 00 BF 20 04 00 BNC BE EF 03 06 00 1A F5 01 00 BF 20 07 00 OFF BE EF 03 06 00 DA B6 01 00 BF 20 FF 00 Get BE EF 03 06 00 19 F7 02 00 BF 20 00 00 LANGUAGE Set ENGLISH BE EF 03 06 00 F7 D3 01 00 05 30 00 00 FRANÇAIS BE EF 03 06 00 67 D2 01 00 05 30 01 00 DEUTSCH BE EF 03 06 00 97 D2 01 00 05 30 02 00 ESPAÑOL BE EF 03 06 00 07 D3 01 00 05 30 03 00 ITALIANO BE EF 03 06 00 37 D1 01 00 05 30 04 00 NORSK BE EF 03 06 00 A7 D0 01 00 05 30 05 00 NEDERLANDS BE EF 03 06 00 57 D0 01 00 05 30 06 00 PORTUGUÊS BE EF 03 06 00 C7 D1 01 00 05 30 07 00 BE EF 03 06 00 A7 D5 01 00 05 30 09 00 BE EF 03 06 00 37 DE 01 00 05 30 10 00 BE EF 03 06 00 57 D5 01 00 05 30 0A 00 SVENSKA BE EF 03 06 00 C7 D4 01 00 05 30 0B 00 PYCCKNN BE EF 03 06 00 F7 D6 01 00 05 30 0C 00 SUOMI BE EF 03 06 00 67 D7 01 00 05 30 0D 00

Names Operation Type Header Command Data CRC Action Type Setting Code
LANGUAGE Set POLSKI BE EF 03 06 00 97 D7 01 00 05 30 0E 00 TÜRKÇE BE EF 03 06 00 07 D6 01 00 05 30 0F 00 Get BE EF 03 06 00 C4 D3 02 00 05 30 00 00 MENU POSITION V Get BE EF 03 06 00 40 D7 02 00 16 30 00 00 Increment BE EF 03 06 00 26 D7 04 00 16 30 00 00 Decrement BE EF 03 06 00 F7 D6 05 00 16 30 00 00 MENU POSITION V
Execute BE EF 03 06 00 A8 C7 06 00 44 70 00 00
MENU POSITION H Get BE EF 03 06 00 04 D7 02 00 15 30 00 00 Increment BE EF 03 06 00 62 D7 04 00 15 30 00 00 Decrement BE EF 03 06 00 B3 D6 05 00 15 30 00 00 MENU POSITION H
Execute BE EF 03 06 00 DC C6 06 00 43 70 00 00
BLANK Set MyScreen BE EF 03 06 00 FB CA 01 00 00 30 20 00 ORIGINAL BE EF 03 06 00 FB E2 01 00 00 30 40 00 BLUE BE EF 03 06 00 CB D3 01 00 00 30 03 00 WHITE BE EF 03 06 00 6B D0 01 00 00 30 05 00 BLACK BE EF 03 06 00 9B D0 01 00 00 30 06 00
Get BE EF 03 06 00 08 D3 02 00 00 30 00 00 BLANK On/Off Set OFF BE EF 03 06 00 FB D8 01 00 20 30 00 00 ON BE EF 03 06 00 6B D9 01 00 20 30 01 00 Get BE EF 03 06 00 C8 D8 02 00 20 30 00 00 START UP Set MyScreen BE EF 03 06 00 CB CB 01 00 04 30 20 00 ORIGINAL BE EF 03 06 00 0B D2 01 00 04 30 00 00 OFF BE EF 03 06 00 9B D3 01 00 04 30 01 00 Get BE EF 03 06 00 38 D2 02 00 04 30 00 00 MyScreen LOCK Set OFF BE EF 03 06 00 3B EF 01 00 C0 30 00 00 ON BE EF 03 06 00 AB EE 01 00 C0 30 01 00 Get BE EF 03 06 00 08 EF 02 00 C0 30 00 00 MESSAGE Set OFF BE EF 03 06 00 8F D6 01 00 17 30 00 00 ON BE EF 03 06 00 1F D7 01 00 17 30 01 00 Get BE EF 03 06 00 BC D6 02 00 17 30 00 00 TEMPLATE Set TEST PATTERN BE EF 03 06 00 43 D9 01 00 22 30 00 00 DOT-LINE 1 BE EF 03 06 00 D3 D8 01 00 22 30 01 00 DOT-LINE 2 BE EF 03 06 00 23 D8 01 00 22 30 02 00 DOT-LINE 3 BE EF 03 06 00 B3 D9 01 00 22 30 03 00 DOT-LINE 4 BE EF 03 06 00 83 DB 01 00 22 30 04 00 Get BE EF 03 06 00 70 D9 02 00 22 30 00 00 TEMPLATE On/Off Set OFF BE EF 03 06 00 BF D8 01 00 23 30 00 00 ON BE EF 03 06 00 2F D9 01 00 23 30 01 00 Get BE EF 03 06 00 8C D8 02 00 23 30 00 00 CLOSED CAPTION
Set OFF BE EF 03 06 00 FA 62 01 00 00 37 00 00 ON BE EF 03 06 00 6A 63 01 00 00 37 01 00 Get BE EF 03 06 00 C9 62 02 00 00 37 00 00 CLOSED CAPTION
Set CAPTIONS BE EF 03 06 00 06 63 01 00 01 37 00 00 TEXT BE EF 03 06 00 96 62 01 00 01 37 01 00 Get BE EF 03 06 00 35 63 02 00 01 37 00 00
Reset · Reset

Names Operation Type Header Command Data CRC Action Type Setting Code
Set 1 BE EF 03 06 00 D2 62 01 00 02 37 01 00 2 BE EF 03 06 00 22 62 01 00 02 37 02 00 3 BE EF 03 06 00 B2 63 01 00 02 37 03 00 4 BE EF 03 06 00 82 61 01 00 02 37 04 00 Get BE EF 03 06 00 71 63 02 00 02 37 00 00 SOURCE SKIP COMPUTER IN 1
Set NORMAL BE EF 03 06 00 FE 78 01 00 20 22 00 00 SKIP BE EF 03 06 00 6E 79 01 00 20 22 01 00 Get BE EF 03 06 00 CD 78 02 00 20 22 00 00 SOURCE SKIP COMPUTER IN 2
Set NORMAL BE EF 03 06 00 CE 79 01 00 24 22 00 00 SKIP BE EF 03 06 00 5E 78 01 00 24 22 01 00 Get BE EF 03 06 00 FD 79 02 00 24 22 00 00 SOURCE SKIP
Set NORMAL BE EF 03 06 00 8A 79 01 00 27 22 00 00 SKIP BE EF 03 06 00 1A 78 01 00 27 22 01 00 Get BE EF 03 06 00 B9 79 02 00 27 22 00 00 SOURCE SKIP
Set NORMAL BE EF 03 06 00 BA 78 01 00 23 22 00 00 SKIP BE EF 03 06 00 2A 79 01 00 23 22 01 00 Get BE EF 03 06 00 89 78 02 00 23 22 00 00 SOURCE SKIP
Set NORMAL BE EF 03 06 00 62 7B 01 00 29 22 00 00 SKIP BE EF 03 06 00 F2 7A 01 00 29 22 01 00
Get BE EF 03 06 00 51 7B 02 00 29 22 00 00 SOURCE SKIP
Set NORMAL BE EF 03 06 00 32 78 01 00 25 22 00 00 SKIP BE EF 03 06 00 A2 79 01 00 25 22 01 00 Get BE EF 03 06 00 01 78 02 00 25 22 00 00 SOURCE SKIP
Set NORMAL BE EF 03 06 00 46 79 01 00 22 22 00 00 SKIP BE EF 03 06 00 D6 78 01 00 22 22 01 00 Get BE EF 03 06 00 75 79 02 00 22 22 00 00 SOURCE SKIP
Set NORMAL BE EF 03 06 00 02 79 01 00 21 22 00 00 SKIP BE EF 03 06 00 92 78 01 00 21 22 01 00 Get BE EF 03 06 00 31 79 02 00 21 22 00 00 SOURCE SKIP
Set NORMAL BE EF 03 06 00 26 7B 01 00 2A 22 00 00 SKIP BE EF 03 06 00 B6 7A 01 00 2A 22 01 00 Get BE EF 03 06 00 15 7B 02 00 2A 22 00 00 AUTO SEARCH Set OFF BE EF 03 06 00 B6 D6 01 00 16 20 00 00 ON BE EF 03 06 00 26 D7 01 00 16 20 01 00 Get BE EF 03 06 00 85 D6 02 00 16 20 00 00 DIRECT ON Set OFF BE EF 03 06 00 3B 89 01 00 20 31 00 00 ON BE EF 03 06 00 AB 88 01 00 20 31 01 00 Get BE EF 03 06 00 08 89 02 00 20 31 00 00 AUTO OFF Get BE EF 03 06 00 08 86 02 00 10 31 00 00 Increment BE EF 03 06 00 6E 86 04 00 10 31 00 00 Decrement BE EF 03 06 00 BF 87 05 00 10 31 00 00 SHUTTER TIMER Set 1h BE EF 03 06 00 27 92 01 00 06 24 01 00 3h BE EF 03 06 00 47 93 01 00 06 24 03 00 6h BE EF 03 06 00 17 90 01 00 06 24 06 00 Get BE EF 03 06 00 84 93 02 00 06 24 00 00 LAMP TIME LOW Get BE EF 03 06 00 C2 FF 02 00 90 10 00 00 LAMP TIME HIIGH Get BE EF 03 06 00 2A FD 02 00 9E 10 00 00 LAMP TIME Reset Execute BE EF 03 06 00 58 DC 06 00 30 70 00 00 FILTER TIME LOW Get BE EF 03 06 00 C2 F0 02 00 A0 10 00 00 FILTER TIME HIGH Get BE EF 03 06 00 D6 FC 02 00 9F 10 00 00 FILTER TIME Reset Execute BE EF 03 06 00 98 C6 06 00 40 70 00 00





Names Operation Type Header Command Data CRC Action Type Setting Code
MY SOURCE Get BE EF 03 06 00 C9 38 02 00 20 36 00 00 MY IMAGE Set OFF BE EF 03 06 00 3A C3 01 00 00 35 00 00 IMAGE-1 BE EF 03 06 00 AA C2 01 00 00 35 01 00 IMAGE-2 BE EF 03 06 00 5A C2 01 00 00 35 02 00 IMAGE-3 BE EF 03 06 00 CA C3 01 00 00 35 03 00 IMAGE-4 BE EF 03 06 00 FA C1 01 00 00 35 04 00 Get BE EF 03 06 00 09 C3 02 00 00 35 00 00 MY IMAGE IMAGE-1
Execute BE EF 03 06 00 71 C3 06 00 01 35 00 00
Execute BE EF 03 06 00 35 C3 06 00 02 35 00 00
Execute BE EF 03 06 00 C9 C2 06 00 03 35 00 00
Execute BE EF 03 06 00 BD C3 06 00 04 35 00 00
REMOTE FRONT Set Off BE EF 03 06 00 FF 32 01 00 00 26 00 00 On BE EF 03 06 00 6F 33 01 00 00 26 01 00 Get BE EF 03 06 00 CC 32 02 00 00 26 00 00 REMOTE REAR Set Off BE EF 03 06 00 03 33 01 00 01 26 00 00 On BE EF 03 06 00 93 32 01 00 01 26 01 00 Get BE EF 03 06 00 30 33 02 00 01 26 00 00 REMOTE TOP Set Off BE EF 03 06 00 47 33 01 00 02 26 00 00 On BE EF 03 06 00 D7 32 01 00 02 26 01 00 Get BE EF 03 06 00 74 33 02 00 02 26 00 00 REMOTE ID Set ALL BE EF 03 06 00 9F 30 01 00 08 26 00 00 1 BE EF 03 06 00 0F 31 01 00 08 26 01 00
2 BE EF 03 06 00 FF 31 01 00 08 26 02 00 3 BE EF 03 06 00 6F 30 01 00 08 26 03 00 4 BE EF 03 06 00 5F 32 01 00 08 26 04 00 Get BE EF 03 06 00 AC 30 02 00 08 26 00 00 REMOTE FREQUENCY
Set Disable BE EF 03 06 00 FF 3D 01 00 30 26 00 00 Enable BE EF 03 06 00 6F 3C 01 00 30 26 01 00 Get BE EF 03 06 00 CC 3D 02 00 30 26 00 00 REMOTE FREQUENCY
Set Disable BE EF 03 06 00 03 3C 01 00 31 26 00 00 Enable BE EF 03 06 00 93 3D 01 00 31 26 01 00 Get BE EF 03 06 00 30 3C 02 00 31 26 00 00 FOCUS Increment BE EF 03 06 00 6A 93 04 00 00 24 00 00 Decrement BE EF 03 06 00 BB 92 05 00 00 24 00 00 ZOOM Increment BE EF 03 06 00 96 92 04 00 01 24 00 00 Decrement BE EF 03 06 00 47 93 05 00 01 24 00 00 LENS SHIFT -V Increment BE EF 03 06 00 D2 92 04 00 02 24 00 00 Decrement BE EF 03 06 00 03 93 05 00 02 24 00 00 LENS SHIFT -H Increment BE EF 03 06 00 2E 93 04 00 03 24 00 00 Decrement BE EF 03 06 00 FF 92 05 00 03 24 00 00 LENS SHIFT CENTERING
Execute BE EF 03 06 00 B8 93 06 00 04 24 00 00


What the fault codes shown on the display mean and how to clear them.