Page 2 of the InFocus C95 user manual — 5 COMMAND RETURN CODES ..................................................................................................... 6
Page 2 · click to enlarge
Page 2

1 SETTING UP 3

1.1 RS232 CONTROL CABLE 3 1.2 RS232 SETTINGS 3

2 GENERAL 4

3 FUNCTION TYPE .......................................................................................................................... 4

4 PROTOCOL MESSAGES............................................................................................................... 4

4.1 MESSAGE FORMATS 4 4.1.1 Message Head 4 4.1.2 Message Body 5 4.1.2.1 Field description 5

5 COMMAND RETURN CODES 6

TRANSACTION EXAMPLES............................................................................................................... 6

6 TABLE OF FUNCTIONS................................................................................................................ 8

APPENDIX 1: CRC CALCULATION ALGORITHM ......................................................................... 10

Page 3 of the InFocus C95 user manual — 1 SETTING UP
Page 3 · click to enlarge
Page 3

1 SETTING UP

To enable serial control, do the following:

  • Remove the check mark from “ Serial Mouse” in the Projector’s FEATURE MENU. This changes the Baudrate from 1200 to 9600 and turns of the Serial mouse data.
  • Connect the serial (COM) port from the Host to the RS232 connector on the projector

1.1 Rs232 Control Cables Please order the following parts:

Part NumberDescription 301.102AMouse Cable 4 meter 301.113BPC Mouse Adapter RS232 Straight

1.2 RS232 Settings If SerialMouse is deselected the setting is:

InFocus C95 — 1 SETTING UP diagram (page 3)
Fig. 1
ParameterDefault setting Baudrate9600 Data bit8 Parity bitNone Stop bit1 Flow ControlNone

If SerialMouse is selected the setting is:

InFocus C95 — 1 SETTING UP diagram (page 3)
Fig. 2
ParameterDefault setting Baudrate1200 Data bit8 Parity bitNone Stop bit1 Flow ControlNone

If the serial mouse is enabled the projector sends mouse data whenever the user moves the trackball on the Batmouse.

Page 4 of the InFocus C95 user manual — 4 PROTOCOL MESSAGES
Page 4 · click to enlarge
Page 4

2 GENERAL

This document describes the Communication Protocol between a Proxima® Projector and a Computer (Host). By using this connection the Host will be able control the projector.

This document is HEX command based only and a regular Terminal program like hyperterminal etc. can therefore not directly be used unless the COM port are activated by the user. This document is aimed at control systems in general which is HEX based.

3 FUNCTION TYPE

The Function is grouped in four different function types:

InFocus C95 — 3 FUNCTION TYPE diagram (page 4)
Fig. 3
Function typeComments ExecuteAn execute function executes an action on the projector, i.e. only one state. StateA State function performs a set operation from a predefined list of states. Not all values in the range have to be legal. State StringAs state but returns ASCII strings AdjustAn adjust function is characterized by Maximum > Minimum. And all the integer values between Minimum and Maximum are legal.

4 PROTOCOL MESSAGES

4.1 Message Formats The message is always divided in a header and a body part:

Message Head (7Byte) Message Body (6Byte)

4.1.1 Message Head The message head has the following structure:

Byte 0Byte 1Byte 2Byte 3Byte 4Byte 5Byte 6 Magic NumberBody sizeCRC 0xBE0xEF0x800x060x00CRC lo _CRC hi _

All values is in hexadecimal indicated with the leading 0x. The Magic number is used for synchronizing the start of a message. The Body size is set to the number of bytes contained in the Body part of the message.

Page 5 of the InFocus C95 user manual — 4.1.2.1 Field description
Page 5 · click to enlarge
Page 5

Currently there is only one type of body so the size is fixed to 0x0006. The CRC field contains the CRC of the message. The CRC algorithm is given in Appendix 1. To disable CRC set CRC_lo=0x00 and CRC_hi = 0x00. The Message Head – if the CRC are disabled – then looks like the following string: 0xBE 0xEF 0x80 0x06 0x00 0x00 0x00. This Head will be present in all strings sent to the projector from the host.

4.1.2 Message Body The message body has the following structure:

Byte 0Byte 1Byte 2Byte 3Byte 4Byte 5 Operation TypeFunctionValue OpTypeLo0x00FuncNum lo _0x00Opval lo _Opval hi _

4.1.2.1 Field description

Field NameField ValueDescription Operation TypeOpTypeLo 0x01Operation Set. Set current value 0x02Operation Get. Gets the current value 0x03Operation Initialize. Initialize the value to default. Should not be used 0x04Operation Increment. Increment the value by one step. Only valid for “Adjust” functions. 0x05Operation Decrement. Decrement the value by one step. Only valid for “Adjust” functions. 0x06Operation Execute. Execute the operation. Only used for “Execute” operations FunctionFuncNumThe actual function number to execute. A list of usable FuncNum is given in Chapter 9 Value-Only used by Operation Set. The actual value to set the operation to. For all other operation actions, this field is set to 0x0000.
Page 6 of the InFocus C95 user manual — Example 4: Hex sequence for power on (with CRC deactivated)
Page 6 · click to enlarge
Page 6

5 COMMAND RETURN CODES

The Serial protocol returns an acknowledgment (“return code”) for every packet sent. If the host sends a packet, then the projector acknowledge the receipt of this packet. The return codes are detailed in the table below.

Command Return Code NameReturn Code ValueDescription ACK0x06Packet acknowledged – no errors. Normal response when receiving NAK0x15Packet not acknowledged – some error occurred in receiving this packet. Usually Indicates a CRC error. ERR0x1C 0xXXXXPacket was received OK, but an error occurred when executing the command contained in the Packet. The two bytes following the 0x1C (0xXXXX) are the error code VAL0x1D 0xXX 0xYYPacket value returned. This return code will be sent in response to a Operation packet of type OPERATION GET. The first byte after 0x1D _ (0xXX), is the least-byte of the returned value. The 0xYY is the most significant-byte of the returned value. STRINGStrings 0x06ASCII Strings and at last ACK

TRANSACTION EXAMPLES

Example 1Set Host: Projector Operation Set Packet => <= ACK
Example 2Get Operation Get Packet => <= VAL

VAL=0x1D 0x00 0x03 means that 0x0300 is returned

Example 3Hex sequence for Set Brightness to 70% => 0.7*255 = 178 = 0xB2

Host:

0xBE 0xEF 0x80 0x06 0x00 0x2E 0x04 0x01 0x00 0x11 0x00 0xB2 0x00

Magic number Body size CRC Op.type Function Value

7byte Message Head 6byte Message Body

Projector0x06

Example 4: Hex sequence for power on (with CRC deactivated)

Page 7 of the InFocus C95 user manual — Example 5: Hex sequence for get Brightness
Page 7 · click to enlarge
Page 7
Host0xBE 0xEF 0x80 0x06 0x00 0x00 0x00 0x01 0x00 0x01 0x00 0x01 0x00

Example 5: Hex sequence for get Brightness

Host=> 0xBE 0xEF 0x80 0x06 0x00 0xBD 0x70 0x02 0x00 0x11 0x00 0x00 0x00

Example 5: To get ASCII Information Set Parameter in the State String function Host: Projector Operation Set Packet =>

Page 8 of the InFocus C95 user manual — 6 TABLE OF FUNCTIONS
Page 8 · click to enlarge
Page 8

6 TABLE OF FUNCTIONS

Scr.dep = Source depended

InFocus C95 — 6 TABLE OF FUNCTIONS diagram (page 8)
Fig. 4
FunctionFuncNumF.typeStatesMinimumMaximum Power0x01State1 (On) 0 (Off)-- Reset0x02Execute--- Tune0x03Adjust-0255 Width0x04Adjust-04095 Horizontal position0x05Adjust-04095 Vertical position0x06Adjust-04095 ColorTemp0x07Adjust-03 Rear0x08State1 (On) 0 (Off)-- Ceiling0x09State1 (On) 0 (Off)-- Factory reset0x0AExecute---
InFocus C95 — 6 TABLE OF FUNCTIONS diagram (page 8)
Fig. 5
FunctionFuncNumF.typeStatesMinimumMaximum Contrast0x10Adjust-0255 Brightness0x11Adjust-0255 Tint0x12Adjust-0255 Color0x13Adjust-0255 Sharpness0x14State5(Softest) 6(Soft) 7(Medium) 8(Sharp) 9(Sharpest)-- Keystone0x15Adjust-0255 16:90x16State1(On) 0 (Off)--
InFocus C95 — 6 TABLE OF FUNCTIONS diagram (page 8)
Fig. 6
FunctionFuncNumF.typeStatesMinimumMaximum Volume0x20Adjust-0100 Mute0x21State1 (On) 0 (Off)--
Page 9 of the InFocus C95 user manual — 6 TABLE OF FUNCTIONS
Page 9 · click to enlarge
Page 9
InFocus C95 — 6 TABLE OF FUNCTIONS diagram (page 9)
Fig. 7
FunctionFuncNumF.typeStatesMinimumMaximum On screen display0x30State1 (On) 0 (Off)-- Source0x32State0 (VGA1) 1 (DVI1) 2 (S-VIDEO1) 3 (CVBS1) 4 (VGA2) 5 (DVI2) 6 (S-VIDEO2) 7 (CVBS2)-- Language0x33State0 (English) 1(Japanese) 2(Norwegian) 3 (Deutch) 4 (Italian) 5 (Spanish) 6 (Korean) 7 (Simpl Chi) 8 (Trad Chi) 9 (Portugeese) 10(French)-- Black0x34State1 (On) 0 (Off)-- Magnify0x35Adjust-026 Pan horizontal0x36Adjust-Scr.depScr.dep Pan vertical0x37Adjust-Scr.depScr.dep Freeze0x38State1 (On) 0 (Off)01 PnP0x39State1 (On) 0 (Off)-- DPMS0x3AState1 (On) 0 (Off)-- Source Search0x3BState1 (On) 0 (Off)-- SerialMouse10x3CState1 (On) 0 (Off)-- MenuTimeOut0x3DAdjust-550
InFocus C95 — 6 TABLE OF FUNCTIONS diagram (page 9)
Fig. 8
FunctionFuncNumF.typeStatesMinimumMaximum Information0x40State Strings0 Respons is Source. information . 1 Respons is Service. information--
Page 10 of the InFocus C95 user manual — APPENDIX 1: CRC CALCULATION ALGORITHM
Page 10 · click to enlarge
Page 10

APPENDIX 1: CRC CALCULATION ALGORITHM

The following ‘C’ code can be used to calculate the 16-bit CRC required for all packets. The CRC is contained in the packet header and is calculated for the entire packet (header plus body). The CRC calculation is performed with the CRC bytes of the packet header initialized to zero.

// Using two 256 byte lookup tables, quickly calculate a 16-bit CRC on // a block of data. // Params: // pcData : Pointer to data to calculate CRC on. // nCount : Number of data bytes. // Return: 16-bit CRC value. WORD CalculateCRC16 (BYTE *pcData, int nCount) {

BYTE cCRCHi = 0xFF; // high byte of CRC initialized BYTE cCRCLo = 0xFF; // low byte of CRC initialized BYTE cIndex; // will index into CRC lookup table while (nCount--) // step through each byte of data {

cIndex = cCRCHi ^ *pcData++; // calculate the CRC cCRCHi = cCRCLo ^ cCRCHiArray[cIndex]; cCRCLo = cCRCLoArray[cIndex]; } return (cCRCHi

Page 11 of the InFocus C95 user manual — APPENDIX 1: CRC CALCULATION ALGORITHM
Page 11 · click to enlarge
Page 11

// Lookup table used for hi-byte of CRC static const BYTE cCRCHiArray[] = { 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x01,0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80,0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81, 0x40, 0x01,0xC0, 0x80, 0x41, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81,0x40, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x00,0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x01, 0xC0, 0x80,0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x00,0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80,0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x01,0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81,0x40, 0x01, 0xC0, 0x80, 0x41, 0x01, 0xC0, 0x80, 0x41, 0x00,0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81,0x40, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x01,0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81,0x40, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x01,0xC0, 0x80, 0x41, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81,0x40, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x01,0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80,0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81, 0x40, 0x01,0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80,0x41, 0x01, 0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x01,0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81,0x40, 0x01, 0xC0, 0x80, 0x41, 0x01, 0xC0, 0x80, 0x41, 0x00,0xC1, 0x81, 0x40, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80,0x41, 0x00, 0xC1, 0x81, 0x40, 0x01, 0xC0, 0x80, 0x41, 0x01,0xC0, 0x80, 0x41, 0x00, 0xC1, 0x81, 0x40 };

Page 12 of the InFocus C95 user manual — APPENDIX 1: CRC CALCULATION ALGORITHM
Page 12 · click to enlarge
Page 12

// Lookup table used for low-byte of CRC static const BYTE cCRCLoArray[] = { 0x00, 0xC0, 0xC1, 0x01, 0xC3, 0x03, 0x02, 0xC2, 0xC6,0x06, 0x07, 0xC7, 0x05, 0xC5, 0xC4, 0x04, 0xCC, 0x0C, 0x0D,0xCD, 0x0F, 0xCF, 0xCE, 0x0E, 0x0A, 0xCA, 0xCB, 0x0B, 0xC9,0x09, 0x08, 0xC8, 0xD8, 0x18, 0x19, 0xD9, 0x1B, 0xDB, 0xDA,0x1A, 0x1E, 0xDE, 0xDF, 0x1F, 0xDD, 0x1D, 0x1C, 0xDC, 0x14,0xD4, 0xD5, 0x15, 0xD7, 0x17, 0x16, 0xD6, 0xD2, 0x12, 0x13,0xD3, 0x11, 0xD1, 0xD0, 0x10, 0xF0, 0x30, 0x31, 0xF1, 0x33,0xF3, 0xF2, 0x32, 0x36, 0xF6, 0xF7, 0x37, 0xF5, 0x35, 0x34,0xF4, 0x3C, 0xFC, 0xFD, 0x3D, 0xFF, 0x3F, 0x3E, 0xFE, 0xFA,0x3A, 0x3B, 0xFB, 0x39, 0xF9, 0xF8, 0x38, 0x28, 0xE8, 0xE9,0x29, 0xEB, 0x2B, 0x2A, 0xEA, 0xEE, 0x2E, 0x2F, 0xEF, 0x2D,0xED, 0xEC, 0x2C, 0xE4, 0x24, 0x25, 0xE5, 0x27, 0xE7, 0xE6,0x26, 0x22, 0xE2, 0xE3, 0x23, 0xE1, 0x21, 0x20, 0xE0, 0xA0,0x60, 0x61, 0xA1, 0x63, 0xA3, 0xA2, 0x62, 0x66, 0xA6, 0xA7,0x67, 0xA5, 0x65, 0x64, 0xA4, 0x6C, 0xAC, 0xAD, 0x6D, 0xAF,0x6F, 0x6E, 0xAE, 0xAA, 0x6A, 0x6B, 0xAB, 0x69, 0xA9, 0xA8,0x68, 0x78, 0xB8, 0xB9, 0x79, 0xBB, 0x7B, 0x7A, 0xBA, 0xBE,0x7E, 0x7F, 0xBF, 0x7D, 0xBD, 0xBC, 0x7C, 0xB4, 0x74, 0x75,0xB5, 0x77, 0xB7, 0xB6, 0x76, 0x72, 0xB2, 0xB3, 0x73, 0xB1,0x71, 0x70, 0xB0, 0x50, 0x90, 0x91, 0x51, 0x93, 0x53, 0x52,0x92, 0x96, 0x56, 0x57, 0x97, 0x55, 0x95, 0x94, 0x54, 0x9C,0x5C, 0x5D, 0x9D, 0x5F, 0x9F, 0x9E, 0x5E, 0x5A, 0x9A, 0x9B,0x5B, 0x99, 0x59, 0x58, 0x98, 0x88, 0x48, 0x49, 0x89, 0x4B,0x8B, 0x8A, 0x4A, 0x4E, 0x8E, 0x8F, 0x4F, 0x8D, 0x4D, 0x4C, 0x8C,0x44, 0x84, 0x85, 0x45, 0x87, 0x47, 0x46, 0x86, 0x82,0x42,0x43, 0x83, 0x41, 0x81, 0x80, 0x40 };

Ask about the InFocus C95

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the InFocus C95

Be the first to ask — other owners or our team will answer.

Original document

InFocus C95 manual PDF

12 pages·78 KB·Projector·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…