Hope Industrial Systems, Inc. User M anual 17” Rack M ount Indust rial Monitor Revision D Model No. HIS-RL17- _ _ _ D.
2 Table of Contents SA FETY A ND REGULATORY INF ORM A T ION ....................................................................3 W arning ......................................... ......................................................................
3 Safety and Regulatory Information Warning To p revent fire or sho ck hazard, do no t expose the un it to rain or mo isture. Dangerously high vo ltages are present inside t he unit. Do n ot disassemble th e unit. Refer servicing to qualified person nel only.
4 Control Panel Buttons and Indicators Control Panel But ton Mo de Description OSD M enu Alway s Opens the On-Scr een Display (OSD) m enu. Also used to exit the OSD m enu or to return to the pre- vious menu. W hen the OSD Menu is NOT Display ed Perform s a c ustom function selected by the user.
5 Control Panel But ton Mo de Description A uto Adjust Alway s Use this button for auto adjus tm ent of the display . Auto adjustm ent allows the monitor to self-adj ust to the incoming video signal. The values of f ine, coarse and position are adjusted autom atically.
6 On Screen Display Functions Picture Men u Description Brightness Adjusts the brightness. Direct A ccess Feature : W hen OSD is not on the screen, push the button to adjust the brightness. Contrast Adjusts the contras t. Mag icBright Provides an optimum viewing envi ronm ent depending on the contents of the im age on screen.
7 Color Men u Description Mag icColor Impr oves digital image and display s natural color m ore clearly w ithout disturbing the image quality . Ther e are four m odes available: 1) Off: Dis ables the .
8 Image Men u Description Coarse Rem oves noise such as vertical stripes. C oarse adjustm ent m ay move the screen im age area. You may relocate it to the center using the Hori- zontal Control menu.
9 Setup Men u Description Reset Returns settings to f actory defaults. Customiz ed Key Allows y ou to specify a function to activate w hen the Custom ized Key is pressed. Select f rom one of three func tion options: • Mag icBright • Mag icColor • Color Effect Off T imer Allows y ou to set a time for the monitor to turn of f autom atically .
10 Installation Instructions Preparing for Installa tion Important! Perform the fo llowin g steps BEFORE In stallation of t he monito r into the panel. 1. Ensure that suff icient power is availabl e. 2. Ensure that suff icient space is available to allow for proper air f low into and out of the unit.
11 Installatio n into Rack Hope Industrial Sy stem s’ Rack Mount Monitors conf orm to Electronic Industries Ass ociation standard EIA-310-D. Our m onitors will fit in ty pe A, B, or C rack with a wi dth of 19” ( 482.6 mm ) (preferr ed EIA rack width).
12 Touchscreen Driver Installation The enclosed CD- ROM contains docum entation and drivers for all major operating sy stem s (touchscr een models only). To be sure you have the m ost cur rent inform ation, check the fol- lowing Internet address: http://HISmonitors.
13 Setting the Timing Mode Setting the timing mode of yo ur com puter gr aphics adapter (or other video source) is impor- tant for m axim izing the qual ity of the s creen im age and for m inimizing ey e strain. The tim ing mode c onsists of the resolution (exam ple 1280 x 1024) and refr esh rate (or vertical fr equency ; exam ple 60 Hz).
14 Cleaning CA UTIO N! DO NOT USE ABRA SIVE MA TERIALS SUCH A S PA PER TOWELS O R DIRTY SHOP RA GS ON T HE DISPLAY A S IT WILL SCRATCH TH E PROTECT IVE COATING. A LWAYS USE A SOFT CLOT H, PREFERABLY MADE OF COTT ON. Resistive Touchsc reen Mode l Any standard glass c leaner can be used to clean the touchscreen.
15 Troubleshooting Symptom Check List Solutions Do y ou see the “Check Signal Cable” mes sage on screen? Check the video connection from the monitor to the com puter. If running W indows and the computer power is on, reboot the computer and watch for the initial boot and w indows screen.
16 Symptom Check List Solutions Image on screen is not perfect Many possible causes . Try the following solutions. • Make sur e the PC display resolution matc hes one the factor y preset tim ings shown in this manual. • Recall factory setting. Refer to OSD functions in this m anual.
17 Draw ings Front and Side View s.
18 Rear and Bottom View s.
19 Specifications Display Type Thin-f ilm transis tor (T FT) Ac tive Matrix Liquid Cry stal Size 17” (43 cm ) diagonal Image Size 13.3” (338 m m ) x 10.6” (270 m m ) Native Resolution SXGA (1280 x 1024, 5:4 aspect r atio) Plug and Play VESA DDC 2B Minimum Resolution 640 x 350 Pixel Pitch 0.
20 Video Input Connectors HD-15 (optional BNC input; see “Input Signal Formats” for a list of com patible video signals) Input Signal Formats RGB Analog video, 0.
21 Rack Compa tibility EIA Standard EIA-310-D Rack W idth 482.6 mm (19.00”) (prefer red EIA width) EIA Type Rack A, B, or C Mounting 8 Slots, 6.4 mm wide Panel Height 8U, 13.97” (354.8 m m) Enclosure Rating NEMA 1 Physical Depth 2.01” (50.9 m m ) behind bezel Bezel Black Powder-Coated Carbon Steel Front Bezel outside dimensions 19.
22 Factory Prese t Timing Resolution Horizont al Frequency (kHz) Vertical Frequency (Hz) Pixel Clock (M Hz) Sync Polarity (H/V) IBM, 640 x 350 31.469 70.086 25.175 +/- IBM, 640 x 480 31.469 59.940 25.175 -/- IBM, 720 x 400 31.469 70.087 28.322 -/+ MAC, 640 x 480 35.
23 Warranty Statement Who is Covered ? This warranty covers the pu rchas er of thi s produ ct onl y and is not tran sferabl e without ou r written co n- sent.
24 Hope Indust rial Systems, Inc. 1325 Northm eadow Parkway Suite 100 Roswell, GA 30076 Toll Free: (877) 762-9790 Phone: (678) 762-9790 Fax: (678) 762-9789 Sales and Custom er Service: sales@HISm onitors.com Support and Returns: support@HISm onitors.com Accounting Departm ent: accounting@HISm onitors.
An important point after buying a device IBM Rack Mount Industrial Monitor HIS-RL17 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought IBM Rack Mount Industrial Monitor HIS-RL17 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data IBM Rack Mount Industrial Monitor HIS-RL17 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, IBM Rack Mount Industrial Monitor HIS-RL17 you will learn all the available features of the product, as well as information on its operation. The information that you get IBM Rack Mount Industrial Monitor HIS-RL17 will certainly help you make a decision on the purchase.
If you already are a holder of IBM Rack Mount Industrial Monitor HIS-RL17, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime IBM Rack Mount Industrial Monitor HIS-RL17.
However, one of the most important roles played by the user manual is to help in solving problems with IBM Rack Mount Industrial Monitor HIS-RL17. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device IBM Rack Mount Industrial Monitor HIS-RL17 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center