Operators Manual



Hypercom Corporation 2851 West Kathleen Road Phoenix, Arizona 85053 USA
Copyright 1999-2000 by Hypercom Corporation.
Printed in the United States of America.
All rights reserved.
This publication is proprietary to Hypercom Corporation and is intended solely for use by Hypercom customers. This publication may not be reproduced or distributed for any purpose without the written permission of Hypercom Corporation.
The information Hypercom furnishes in this publication is believed to be accurate and reliable. However, the corporation assumes no responsibility for its use and reserves the right to make changes to the publication at any time without notice.
This document applies to the Name of Software.
Hypercom and the Hypercom logo are registered trademarks of Hypercom Corporation. Integrated Enterprise Network is a trademark of Hypercom Corporation.
Hypercom has attempted throughout this publication to distinguish proprietary trademarks from descriptive terms by following the capitalization style the manufacturer uses. Every effort was made to supply complete and correct information. Any error in identifying or reflecting any proprietary marks or notices is inadvertent and unintentional.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC (ICES-003) Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This equipment complies with Part 68 of the FCC Rules. On the bottom of this equipment is a label that contains the FCC Registration Number and Ringer Equivalence Number (REN) for this equipment. If requested, you must provide this information to your telephone company.
NOTE: REN is not required for some types of analog or digital facilities.
This equipment uses an RJ11 jack.
An FCC-compliant telephone cord and modular plug are provided with this equipment. It is designed to be connected to the telephone network or premises wiring using a compatible modular jack that is Part 68-compliant. See installation instructions for details.
The REN is useful to determine the number of devices you may connect to your telephone line and still have all those devices ring when your telephone number is called. In most but not all areas, the sum of the RENs of all devices connected to one line should not exceed five. To be certain of the number of devices you may connect to your line, contact your local telephone company to determine the maximum REN for your calling area.
NOTE: REN is associated with loop-start and ground-start ports. Do not use for E&M or digital ports.
If your telephone equipment causes harm to the telephone network, the telephone company may discontinue your service temporarily. If possible, they will notify you in advance. However, if advance notice is not practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with the FCC.
Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the proper functioning of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service.
If you experience trouble with this telephone equipment, please contact the Hypercom Repairs Department at (602) 504- 5378 for information on obtaining service or repairs. The telephone company may ask that you disconnect this equipment from the network until the problem is corrected or until you are sure that the equipment is not malfunctioning.
This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs.
This telephone receiver is hearing-aid compatible if applicable.
The equipment has been approved to Commission Decision, CTR21, for pan-European single terminal connection to the Public Switched Telephone Network (PSTN). However, due to differences between the individual PSTNs provided in different countries, the approval does not, of itself, give an unconditional assurance of successful operation on every PSTN network termination point. In the event of problems, you should contact your equipment supplier in the first instance.

Before installing this equipment, ensure that it is acceptable for connection to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. Compliance with these conditions may not prevent degraded service in some situations.
A representative designated by the supplier should coordinate repairs to certified equipment. Any repairs or alterations to this equipment or any equipment malfunctions may cause the telephone communications company to request that the user disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority or electrician, as appropriate.
“NOTICE: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals that may be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject as long as the sum of the Ringer Equivalence Numbers of all the devices does not exceed five.




Figure 1-1. ICE 5000 and 5500 terminals 1-1
Figure 1-2. Standard keyboard 1-3
Figure 1-3. Touch-screen display 1-4
Figure 2-1. ICE 5000 power socket 2-1
Figure 2-2. ICE 5500 power socket 2-2
Figure 2-3. ICE 5000 line port 2-3
Figure 2-4. ICE 5500 line port 2-3
Figure 3-1. ICE 5000 printer paper door open 3-5
Figure 3-2. ICE 5000 printer paper installation 3-6
Figure 3-3. ICE 5000 Printer paper installation complete 3-6
Figure 3-4. ICE 5500 printer paper door open 3-7
Figure 3-5. ICE 5500 printer paper installation 3-8
Figure 3-6. ICE 5500 Printer paper installation complete 3-8
Figure 4-1. Basic configuration 4-3
Figure 4-2. Extending basic coverage 4-4
Figure 4-3. Large area coverage 4-6
Figure 4-4. Premises wiring diagram 4-7
Figure 4-5. Basic system example 4-8
Figure 4-6. Extended basic example 4-9
Figure 4-7. Large area example 4-10
940184-003, rev. B Hypercom Corporation ix
List of Figures



Table 1-1. Terminal dimensions 1-5
Table 2-1. Self-test and diagnostics with software loaded 2-4
Table 2-2. Memory page states 2-4
Table 2-3. Self-test and diagnostics when software is not loaded 2-5
940184-003, rev. B Hypercom Corporation xi
List of Tables



The ICE 5000 and 5500 Hardware and Installation Operators Manual is a comprehensive guide to working with Hypercom® ICE 5000 and 5500 terminals.
The ICE 5000 and 5500 terminals are part of the Hypercom Interactive Consumer Environment (ICE) family of touch-screen-based terminals and peripherals. All ICE terminals support traditional terminal functions as well as PIN pad and signature capture functionality. The ICE family employs a modular concept. The basic ICE unit is a multifunction peripheral for either a T7x terminal or ECR. With its printer and modem module attached, it becomes a fully-functional terminal and PIN pad.
The guide contains the following chapters:
n Chapter 4, Wireless POS Terminal Interface: Descriptions and step-by-step instructions for operating the 900 MHz wireless POS terminal interface
This guide is intended for network administrators-merchants-operators-technicians or those who oversee the configuration and daily maintenance of the various networks.
When working with the ICE 5000 or 5500 terminal, the ICE 5000 PIN Pad Loader Operators Manual may be useful as reference material.
940184-003, rev. B Hypercom Corporation xiii

This section provides information to help you understand the procedures and concepts presented in this guide. The following special terms and style conventions are used throughout this document:
Component names: Special bold text highlights certain items including the names of window and dialog box components. This text appears in instructions for specific actions such as clicking buttons, typing in text boxes, and selecting from lists. For example:
From the Main tab page of the Group Definition dialog box, click List.
NOTE: A note contains neutral or positive information supplementing the main text. It is often information
that applies only to special cases.
IMPORTANT: Important statements draw attention to information crucial to using the product successfully.
Pay special attention to Important statements.
Procedures: Numbered procedures have a special graphic appearing in the margin of the text. The words Step-by-Step also appear in bold at the beginning of the procedure. For example:
To perform a procedure:
a. This is a substep.
b. Substeps must be completed in the order given.

Clicking with the mouse: This document assumes you are using a mouse or some other pointing device to move within and among windows and dialog boxes. Therefore, when instructions include clicking an item, it means you use the mouse to move the cursor onto the desired item. You then click the mouse button to highlight the item or cause an action to occur. For example:
Click the Totals check box to activate the online totals feature.
xiv ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Introduction

Series of actions: The greater-than sign (>) appears in procedures indicating a series of simple, related actions using the mouse pointer. The resulting action typically starts a utility or opens a dialog box. For example
From the Term-Master main menu, click Network > Definitions’.
940184-003, rev. B Hypercom Corporation xv
Introduction




This chapter provides important information to properly set up and test both the ICE 5000 and 5500 terminals. To prevent damage to the POS terminals and possible personal injury, be sure to read this document before installing the ICE terminals.


Figure 1-1. ICE 5000 and 5500 terminals

This section describes general safety precautions that must be followed to ensure proper installation and maintenance of the POS product family.
Electrical Safety: Observe all normal electrical safety practices when operating any equipment attached to an active power source.
Authorized Service: Only a Hypercom authorized service technician or an authorized repair station can perform equipment servicing, adjustment, maintenance, or repairs on the POS products.
Electrostatic Damage: Before performing any maintenance on POS products, ensure that you wear a static strap and are grounded to the POS products.
To ensure protection of the telecommunications port against lightning damage, this product requires connection to the building protective earthing. Therefore, the integrity of protective earthing must be ensured. Use only the Hypercom provided power supply and power cord. Ensure that power is supplied from a suitable power outlet to the supply when the terminal is connected to the telephone line
Electromagnetic Compatibility: This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take appropriate measures

1-2 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 1

Tamper resistance is provided through the use of intrusion detectors and a secure CPU/RAM module that is housed in a sealed metal case. PIN encryption, MAC-ing, encryption key storage, and management are performed in a separate secure co-processor with its own internal RAM. To further prevent tampering, the entire ICE 5000 and 5500 terminal housings are ultrasonically welded and sealed. The ICE 5000 and 5500 terminal supports as many as three integrated Security Access Modules (SAMs) for various smart card solutions.
The keyboard consists of 12 keys: 10 numeric and 2 control keys.
The keyboard provides:
n Buttons sized to meet various cardholder needs
n Audible signals that notify the cardholder of the action being taken

Figure 1-2. Standard keyboard
The ICE 5000 and 5500 are both a terminal and a PIN pad. The terminals contain all the necessary security features required for secure PIN encryption and message authentication. By allowing transaction entry and PIN entry through the same device, the ICE 5000 and 5500 reduces cost and footprint. Additionally, the ICE 5000 and 5500 both feature a touch-screen. This allows the costomer to activate complex applications.
The ICE 5000 only, includes a PIN pad port allowing the attachment of either a traditional PIN pad or an ICE pad. An ICE pad is basically an ICE 5000 terminal without the printer and modem module. It is specifically programmed to function as a consumer interface device, supporting transaction selection, PIN pad, and signature capture functions.
940184-003, rev. B Hypercom Corporation 1-3
Hardware Information

The ICE 5000 and 5500 terminals are built around a graphic touch-screen that provides a high degree of flexibility and an intuitive user environment. Additionally, the graphics screen can deliver advertising and other promotional messages directly to the consumer.
The easy-to-operate nature of the touch-screen reduces the need for cashier training. It allows trouble- free operation by consumers in the PIN pad and signature capture pad modes. It also allows the support of complex new applications such as loyalty, which on a traditional terminal requires many keystrokes and long transaction entry times.
For operation in dimly lit environments such as restaurants, the screen is equipped with a backlight.
The standard configuration for the ICE 5000 and 5500 terminals includes a 1.7 inch by 2.6 inch graphic dot matrix touch screen that is capable of character, graphics, and signature display. While in character mode, the display resolution is 160 pixels by 80 pixels. The character display has 10 lines with 26 characters for each line. Graphic keys displayed on the screen initiate most functions.
NOTE: This display is configurable.

Figure 1-3. Touch-screen display
The ICE 5000 and 5500 magnetic stripe read (MSR) card reader uses Track 1 and 2. Track 3 is optional.
The ICE 5000 and 5500 terminals integrate a high-speed, six lines per second, thermal printer that provides quiet and trouble-free operation. Since the thermal printer does not use a ribbon, its support requirement is reduced. The small number of moving parts results in improved reliability.
The thermal paper allows high-quality printing with a long receipt life. When using the correct paper, receipt life or the time before fading exceeds five years.
1-4 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 1

The most troublesome component of any POS terminal is the printer. The auto receipt cutter on the ICE 5000 and 5500 is designed to eliminate the need to manually tear the receipt. The first receipt prints and cuts, then the second receipt prints and cuts. Users do not have to manually tear the paper from the terminal, eliminating paper jams.
The ICE 5000 and 5500 terminals incorporate the new Hypercom FastPOS™ 9600 bps modem. While fully compatible with the current 300, 1200, and 2400 bps modems, the FastPOS modem, when working with a FastPOS network node, provides 9600 bps throughput for transactions, batches, and software downloading.
FastPOS uses a new technology to achieve 9600 bps throughput and 0.5 second training times at a cost that is comparable to the cost of 2400 bps modems.
FastPOS results in faster transactions and lower transaction costs. For example, at a 5-cents-per- minute 800 dial rate, with a 1-second billing interval, a FastPOS transaction costs less than 0.5 cents. More importantly, FastPOS enables large data blocks to be transmitted without a cost penalty. Many of the new opportunities created by the touch screen of the ICE 5000 or 5500 become more practical when high-speed communications are available.
The ICE 5000 and 5500 terminals contain a mimimum of 1MB of RAM.
The power requirements for the ICE terminals are 24V, .6A, 85-250 VAC, 50/60 Hz, 15VA.
The dimensions for the ICE 5000 and 5500 are shown in the following table:
Table 1-1. Terminal dimensions
ICE 5000 9 in. 5.33 in. 3.5 in.
ICE 5500 10 in. 5.28 in. 2.75 in.
940184-003, rev. B Hypercom Corporation 1-5
Hardware Information




This section contains inportant information that will help properly install ICE 5000 and 5500 terminals.
Use the following procedures to power up the ICE 5000 or 5500 terminals.
To power up the ICE terminal:

Figure 2-1. ICE 5000 power socket


Figure 2-2. ICE 5500 power socket

Disconnect the AC electric power before replacing the printer module.
Do not use an adapter, a power extender adapter, a power extender cable, or an AC outlet that does not have a ground connection.
Do not disassemble the AC adapter. Only a qualified service technician should service the adapter.
The AC adapter was designed for indoor use only. Do not expose to rain or snow.
The reliability of electronic equipment is significantly reduced when it is powered from an ungrounded outlet. Power is connected to the terminal through a low-power AC adapter. Connect only one terminal to each AC adapter.
Use the following procedures to connect a telephone line to the ICE 5000 or 5500 terminals.
To connect a telephone line:
2-2 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 2


Figure 2-3. ICE 5000 line port

Figure 2-4. ICE 5500 line port
Do not insert the telephone line into the Pin pad port.
940184-003, rev. B Hypercom Corporation 2-3
Installation Procedures · Line port · Line port

Following a successful key injection, a double beep indicates that the terminal has automatically initiated its self-diagnostic routine.
The software and download status of the terminal is displayed during the self-test, which lasts approximately four seconds. During this time, if the terminal is loaded with the security key, the displays shown in the following table are typical.
Table 2-1. Self-test and diagnostics with software loaded
Software: Software name and version.
IDENTIFICATION SOFTWARE XX_XXXXXX DLL 00 OS T5KBOOTXXX TERMINAL NNNNNNNN WAIT SELF TEST
DLL: Tracks the number of downloads. This is controlled by Term-Master.
OS: Operating System and version.
Terminal: Terminal ID number.
Installed memory is displayed. The display indicates one megabyte of memory installed.
A memory page may be in one of the states shown in the following table.
Table 2-2. Memory page states
2-4 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B

If the terminal is not loaded with software, the displays shown in the following table are typical.
Table 2-3. Self-test and diagnostics when software is not loaded
The memory page status indicates that no program is loaded.
PE indicates Program Error. In this case, the program is not loaded.
CONFIGURE TERMINAL or CALL HELP - PE
940184-003, rev. B Hypercom Corporation 2-5
Installation Procedures




This chapter provides setup procedures for the Hypercom ICE 5000 and 5500 terminal, including the steps necessary for terminal configuration, program load, and initialization. Please refer to the ICE 5000 PIN Pad Loader Operators Manual when configuring a terminal for Debit Processing.
A configuration sets the parameters the ICE 5000 or 5500 uses to communicate with Term-Master. When the configuration is complete, the terminal is able to receive the terminal application software.
To configure the ICE terminal:

The Idle prompt appears. CONFIGURE TERMINAL OR CALL HELP - PE
1 Touch 1 on the terminal display. MERCHANT PROGRAMMING TERMINAL ID NUMBER XXXXXXXXX Q W E R T Y U I O P A S D F G H J K L ÏZ X C V B N M SPACE CANCEL CLEAR ENTER

2 Type the terminal ID, then touch Enter on the terminal display, or press Enter on the terminal keyboard.
Ï A B C D E F CANCEL CLEAR ENTER
3 Type the initialization number, then touch or press Enter. MERCHANT PROGRAMMING NMS TELEPHONE NO
Ï A B C D E F CANCEL CLEAR ENTER
4 Type the NMS number, then touch or press Enter. MERCHANT PROGRAMMING DIAL 0-TONE 1-PULSE
Ï A B C D E F CANCEL CLEAR ENTER
5 Type 0 for tone dialing or 1 for pulse dialing, then touch or press Enter.
Ï A B C D E F DEL CANCEL CLEAR ENTER
6 Type a PABX code, if necessary, then touch or press Enter. MERCHANT PROGRAMMING TERMINAL ID NUMBER XXXXXXXXX Q W E R T Y U I O P A S D F G H J K L ÏZ X C V B N M SPACE CANCEL CLEAR ENTER
7 Touch Cancel. The terminal displays the Idle prompt.
3-2 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 3

A program load is required when no software is currently in the terminal. When you initiate a program load, the software is the only partialy loaded. Depending on the software applocation, an average program load takes approximately 40 minutes to complete. The initialization process loads the merchant-specific information in a terminal.
MAC software is required when the ICE 5000 or 5500 supports debit processing. Please refer to the ICE 5000 PIN Pad Loader Operators Manual for further details.
To load a program into the ICE terminal:

The Idle prompt appears. PLEASE INITIALIZE OR CALL HELP - PE
1 Touch 2 on the terminal display. PROGRAM LOAD CORRECT? YES OR NO
2 Touch Enter to continue. The following screens appear. PROCESSING YOUR REQUEST Please wait and watch for message
The terminal dials the host. WAITING FOR DIAL TONE DIALING NOW
The terminal waits for the host to answer. WAITING FOR ANSWER
The terminal sends request information to the host. PROCESSING NOW
940184-003, rev. B Hypercom Corporation 3-3
Setup Procedures

After the terminal receives a new program load, an initialization is required to start the terminal operations. In other cases such as a new card type, an initialization is requested to update the terminal parameters. An initialization takes approximately 30 seconds to complete.
During an initialization, the terminal automatically connects to the initialization host to receive the downloading of the initialization parameters, known as the terminal profile.
To initialize an ICE terminals:

After a program load, the terminal displays the following prompt.
2 Touch Yes. The following screens appear. COMMS
The transaction is complete. The terminal displays the Idle prompt.
3-4 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 3

Use the following procedures to install paper in the ICE 5000 or 5500 terminal.
To properly install the printer paper into the termial, read the following steps carefully.
To load the printer paper in the ICE 5000:

Figure 3-1. ICE 5000 printer paper door open
940184-003, rev. B Hypercom Corporation 3-5
Setup Procedures


Figure 3-2. ICE 5000 printer paper installation

Figure 3-3. ICE 5000 Printer paper installation complete
3-6 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 3

To properly install the printer paper into the termial, read the following steps carefully.
To load the printer paper in the ICE 5500:

Figure 3-4. ICE 5500 printer paper door open
940184-003, rev. B Hypercom Corporation 3-7
Setup Procedures


Figure 3-5. ICE 5500 printer paper installation

Figure 3-6. ICE 5500 Printer paper installation complete
NOTE: If the printer fails to advance the paper, you may need to check the printer ON/OFF settings.
Complete the following steps to verify the settings.
3-8 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 3

a. At the main terminal display, touch Terminal Menu.
b. Touch the arrow. The Terminal Main menu prompt appears.
c. Touch Setup. The Setup menu appears.
d. Touch Printer. The Printer prompt appears.
e. Touch On/Off. The Printer Toggle menu prompt appears. The menu displays Printer is
disabled. Enable?.
f. Touch Yes. The terminal changes the printer settings to Enabled and returs to the main menu.
Repeat steps 4 through 9.
940184-003, rev. B Hypercom Corporation 3-9
Setup Procedures




This section applies only for the ICE 5000 terminal, this does not apply to the ICE 5500 terminal.
The ICE 5000, 900 MHz wireless POS terminal interface system offers a high level of customer convenience and reduces the time required to process a POS transaction. Because customers see the process, they have control of the financial transaction and feel an added sense of security. The host POS terminal and peripheral POS devices provide data encryption.
The 900 MHz wireless POS terminal interface consists of the following functional blocks:
n Host terminal: This only applies to the ICE 5000.
n Terminal transceiver interface: Hypercom model FTI01 or for use with a single terminal transceiver, a Hypercom adapter cable, P/N 810170-001.
n Terminal transceiver: Hypercom model FXV01.
n Customer premises wiring: If required.
n Peripheral terminal device: This may be any Hypercom POS terminal or POS terminal accessory such as a PIN pad or signature capture device, with a compatible optional wireless transceiver installed. An example is an ICE POS terminal with an optional FXI01 module and appropriate software installed.
The ICE 5000 900 MHz wireless POS terminal interface system is designed to be transparent to the user. The peripheral device operates with a wireless POS terminal interface system in the same way as when a cable connection exists between a peripheral POS device and a host POS terminal.

This equipment was tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, the equipment may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
n Reorient or relocate the receiving antenna
n Increase the separation between the equipment and receiver
n Connect the equipment to an outlet on a circuit different from that the receiver is connected to
n Consult the dealer or an experienced radio or TV technician for help
This equipment is certified to comply with the limits for a class B computing device, pursuant to FCC Rules. To maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of the manufacturer could void user authority to operate this equipment.
This class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
4-2 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 4

Wireless POS Terminal Interface
Figure 4-1 shows the basic ICE configuration. The terminal transceiver should be less than 100 feet from the peripheral terminal device. This short range reduces the possibility of interference with other communication systems using the same radio spectrum. Causing such interference is a violation of FCC regulations.

Figure 4-1. Basic configuration
Use the following procedure to install the basic system wireless hardware.
To install the basic system:
See the manual provided with the host POS terminal.
3. Mount the terminal transceiver, Hypercom P/N 020123-002, to a vertical surface. Place it as high as possible in an area that has the best visibility from the area where the peripheral terminal devices are used. You may mount the transceiver by using the metal hook or the rubber suction cups provided. An alternate method is to remove the metal hook and the rubber suction cups, replacing them with double-sided tape. The terminal transceiver must not be mounted on or next to metal objects.
940184-003, rev. B Hypercom Corporation 4-3


To avoid damaging the terminal transceiver unit, do not insert the cable connectors from the single unit adapter or the terminal transceiver into any receptacle designated for use with the premises telephone system .
If the basic system does not cover enough space or major gaps exist in the coverage, you can extend the area covered. The example in Figure 4-2 shows how to extend coverage or fill in gaps by adding a terminal transceiver interface and an additional terminal transceiver.

Figure 4-2. Extending basic coverage
Use this procedure for installing the extended basic coverage wireless hardware.
To install the extended basic coverate area:
See the manual provided with the host POS terminal.
4-4 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 4

Wireless POS Terminal Interface
3. Mount the two terminal transceivers, Hypercom P/N 020123-002, to a vertical surface. Place them as high as possible in an area that has the best visibility from the areas where the peripheral devices are used. Separate the transceivers as far as possible from each other while still providing the required coverage. You may mount the transceivers by using the metal hook or the rubber suction cups provided. An alternate method is to remove the metal hook and the rubber suction cups, replacing them with double-sided tape. The terminal transceivers must not be mounted on or next to metal objects.
If the 12-foot cable is not long enough, it may be extended up to 1000 feet by using any four- conductor, one-to-one standard telephone extender cable available at various electronic appliance retail outlets.
You can also have the premises wired for extending the cables. Firms that install telephone cabling in buildings can perform this task because the wiring is identical to a two-circuit telephone system.
To avoid damaging the terminal transceiver unit, do not insert the cable connectors from the single unit adapter or the terminal transceiver into any receptacle designated for use with the premises telephone system.
940184-003, rev. B Hypercom Corporation 4-5

If the area to be serviced is too large for the extended basic coverage, configure the system for large- area coverage. (See Figure 4-3.) Add a power supply, Hypercom P/N 870003-001, to the terminal transceiver interface. The premises wiring may be expanded to support an additional eight terminal transceivers for a total of ten, maximizing the system for large areas or to fill in gaps in coverage.

Figure 4-3. Large area coverage
To install large area coverage:
3. Mount the terminal transceivers, Hypercom P/N 020123-002, to a vertical surface. Place them as high as possible in an area that has the best visibility from the areas where the peripheral terminal devices are used. Separate the transceivers as far as possible from each other while still providing the required coverage. You may mount the transceivers by using the metal hook or the rubber suction cups provided. An alternate method is to remove the metal hook and the rubber suction cups, replacing them with double-sided tape. The terminal transceivers must not be mounted on or next to metal objects.
4-6 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 4

Wireless POS Terminal Interface
If the 12-foot cable is not long enough, it may be extended up to 1000 feet by using any four conductor, one-to-one standard telephone extender cable available at various electronic appliance retail outlets. You can also have the premises wired for extending the cables. Firms that install telephone cabling in buildings can perform this task because the wiring is identical to a two-circuit telephone system.
To avoid damaging the terminal transceiver unit, do not insert the cable connectors from the single unit adapter or the terminal transceiver into any receptacle designated for use with the premises telephone system.
Figure 4-4. Premises wiring diagram
940184-003, rev. B Hypercom Corporation 4-7

Figures 4-5 through 4-7 are installation examples.
Figure 4-5. Basic system example
4-8 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 4

Wireless POS Terminal Interface
Figure 4-6. Extended basic example
940184-003, rev. B Hypercom Corporation 4-9


Figure 4-7. Large area example
4-10 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Chapter 4

Part 15 4-2 Part 68 iv peripheral terminal device 4-1, 4-3 PIN pad xiii, 1-3
cable 4-4 encryption 1-3 pixels 1-4 power requirements 1-5 PSTN 1-2
RAM 1-3 receiver 4-2 REN iv, v
smart card 1-3 security 1-3
key 2-4 self-diagnostic 2-4 setup procedures
loading printer paper 3-5 ICE 5500
loading paper 3-7 initialization 3-4 load program 3-3 wireless 4-3 short range 4-3
FTI01 4-1 Interface 4-1 Term-Master 3-1 thermal printer 1-4 touch-screen 1-4
display 1-4
messages xv Wireless POS Terminal interface
function blocks 4-1 operations 4-1
instructions 4-2
I-12 ICE 5000 and 5500 Hardware and Installation Operators Manual 940184-003, rev. B
Index · Terminal Transceiver






Document Number 940184-003, rev B
Printed in the USA
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.