Copyright 2004 by Hypercom Corporation
All rights reserved. Printed in the United States of America.
This publication is propriety to Hypercom and intended solely for use by Hypercom customers. It may not be reproduced or distributed for any purpose without the written permission of Hypercom.
The information Hypercom furnished in this publication is believed to be accurate and reliable. However, Hypercom assumes no responsibility for its use. Hypercom also reserves the right to make changes to the publication at any time without notice.
Hypercom, Term-Master, and the Hypercom logo are registered trademarks of Hypercom Corporation. IN-tact is a trademark of Hypercom Corporation.
Hypercom has attempted throughout this publication to distinguish proprietary trademarks from descriptive terms by following the capitalization style the manufacturer uses. Every effort was made to supply complete and correct information. Any error in identifying or reflecting any proprietary marks or notices is inadvertent and unintentional.
This product includes software developed by the University of California, Berkeley and its contributors.
This product includes cryptographic software written by Eric Young (eay@cryptsoft.com).
ii Hypercom Corporation

Product Overview 1 Product Features 1 In This Document 2
Overview 3 Dial Backup Feature 3 Operating Modes 4 Operation without an Ethernet Connection 5
Overview 7 Before You Begin 7 Login and Timeouts 8 IP Addressing 9 Using Static IP Addressing 9 Using DHCP 9 Required Fields and Validation of Entries 9 Materials Required 10 Operating System Requirements 10 Data Entry - Use of Special Characters 10 Internet Browser Recommendations 10 Configuration Procedure 10 Navigation 15 Using the Toolbar 16 Configuration Screens 17 IN-tact 1101 Overview Screen 17 System Settings Screen 19 Ethernet Port Settings Screen 20 Ethernet Port Advanced Settings Screen 21 Security Settings Screen 23 Web Interface Settings Screen 24 SNMP Interface Settings Screen 26 Dial Backup Settings Screen 27 Advanced Settings Screen 30 Time Settings Screen 32 Terminal Port Settings Screen 34 Host Port Settings Screen 35 Standard Host Settings Screen 36 Permanent Mode Settings 38 On Demand Mode Settings 39 HTTP Host Settings Screen 41 Merchant Link Host Settings Screen 43
IN-tact 1101 Software Configuration Guide iii

Transaction Settings Screen 44
Overview 45 File Management Functions 46 Loading Firmware 47 Exporting Firmware to a PC 47 Loading a Configuration to the IN-tact 1101 48 Exporting a Configuration to a PC 48 Loading SSL Server Certificates to the IN-tact 1101 48 Deleting an SSL Server Certificate from the IN-tact 1101 50 Load SSL Client Key to IN-tact 50 System Operations Screen 51 Set Date/Time Screen 53 Clear Statistics Screen 54 Dial Backup 55
Overview 57 System Status Screen 58 Terminal Port 60 Host Port Status Screen 61 Error Codes 62 Dial Backup Status 63
Overview 67 Event Logging Setup 68 Event Log View 69 Event Log Message Table 70
Overview 75 System Identification - Managed 76 Ethernet Port Settings - Minimal 77 Ethernet Port Settings - Managed 78 Host Processor Setup - Minimal with Single Host 79 Host Processor Setup - Minimal with Multiple Hosts 82 Transaction Routing - Minimal 86 Merchant Terminal Setup - Minimal 87 SNMP Setup - Managed 88 Determining the NII Value from a Terminal 89
Table of Contents · iv Hypercom Corporation

Performing a Hex Dump 90 Determining the NIIs in Use 90
Overview 91 SNMP Usage 92 Changing a Configuration 92 Setting the configEditionControl Variable 93 Trap Definitions 93 SNMP Variables Used for Setting Time 94 System Error Codes 95 Time Zone Table for SNMP 97 IN-tact 1101 MIB 99
IN-tact 1101 Software Configuration Guide v
Table of Contents

Table of Contents · vi Hypercom Corporation

The Hypercom® IN-tact™ 1101 is an IP gateway device that provides protocol conversion and secure managed connections for Hypercom Point of Sale (POS) terminals. The product is used to convert transactions on a Hypercom POS LAN (HLAN) to Internet Protocol (IP) transactions over Ethernet UTP. The IN-tact 1101 allows you to use your current POS LAN and take advantage of a DSL or cable modem Ethernet connection to access a host using TCP/IP protocol.
The IN-tact 1101 is designed to require no programming by the end user. All configuration is done via software prior to delivery at the point of installation. The IN-tact unit is shipped from the factory with a default software configuration. Further software configuration, such as unique IP addresses, are usually determined and loaded to flash memory by a deployment center or other customer support group. The unit is then sent to the point of installation where final installation consists of simply connecting the unit to power and to the existing network structure.
Basic product features include:
IN-tact 1101 Software Configuration Guide 1

Introduction In This Document
This document provides information for configuring the IN-tact 1101 IP gateway device. In this document, you will find:

The IN-tact 1100 Series IP Gateways are software-driven devices. The functions that a particular model can perform depend on the version of application software that has been loaded into the unit’s memory at the factory. Configuration is performed via a Web Server interface, providing the IN-tact 1101 with a unique IP address and personality. This document discusses the IN-tact 1101 model and how the device is configured using the on-board Web Server. Other operational information, such as loading software updates on the device, viewing the device status, and the Event Log are also discussed.
NOTE: It is important to note that the hardware and software function as a matched set called a “model”.
Self checks are built into the boot process that validate any software loaded on the unit. This prevents programming the unit with an application that is not intended for the specific IN-tact 1100 model. In other words, you cannot change the model number or add features from another model just by loading new software.
In addition to processing IP transactions, the IN-tact 1101 features dial backup capability in the event of ISP (or other) outage that affects the ability to process transactions via the device's Ethernet port. A compatible modem must be physically connected to Port 1 (RS-232) on the IN- tact 1101 and a working telephone line connected to the modem in order to use the dial backup feature. Currently supported modems include:
IN-tact 1101 Software Configuration Guide 3

Software Information Operating Modes
Other models of modems may also work with the IN-tact 1101. However, unlike supported modems, the Last Modem Connect Speed may not be reported correctly on the Dial Backup Status screen.
Within the IN-tact 1101, availability of the Ethernet port is constantly monitored. Once dial backup is enabled, any outage of the Ethernet port lasting longer than five seconds automatically triggers the device to switch to dial backup mode. Likewise, dial backup is automatically disconnected (based on a period of inactivity you specify) once the Ethernet connection is restored. The IN-tact 1101 can be configured to operate indefinitely in dial mode, if so desired.
The IN-tact 1101 can operate in one of three different modes, referred to as “boot modes”. The boot mode is controlled by whether or not the unit’s Reset button has been activated when power is applied. A description of each of the operating modes is provided below.
NOTE: If you have already configured the unit, save your configuration before resetting or erasing the
current configuration as described below. See the “File Management Functions” section on page 46 for details on exporting/importing a configuration file.

Operation without an Ethernet Connection Software Information
The IN-tact 1101 can be configured to use only the modem with a PPP connection instead of using Ethernet, but an Ethernet connection must initially be available in order to configure the device for this type of operation.
To set up for this type of configuration:
The recovery timer becomes meaningless when no Ethernet cable is attached.
IN-tact 1101 Software Configuration Guide 5

Software Information Operation without an Ethernet Connection

No CD-ROMs or diskettes are required to configure the IN-tact 1101. All configuration is done via a resident Web Server application, or alternately, through a SNMP manager. Initial configuration can only be accomplished via the Web Server application. SNMP is disabled by default. You can connect to the Web Server application using an Internet browser. After logging in to the unit, you can use a series of screens to configure the unit to match both the terminal configuration and desired network settings at the point of installation. When all configuration is complete, you must save the settings. The settings are then written to persistent memory within the device and the device restarts. You must then log in to the device again in order to continue. The procedures provided here assume you are configuring the unit for the first time.
The order in which you configure the IN-tact is up to you. The Web Server allows you to go to any screen, at any time, in any order. The configuration screens are presented here in the order in which they appear on the navigation tree of the Web Server application. However, once you are familiar with the configuration process, you can configure the device in any order that makes sense to you.
It is important to note that you can export a configuration from one IN-tact 1101 and import it into another. This can save time if you are tasked with configuring multiple devices. Rather than having to configure all of the settings on each device, you can configure one, export the configuration, then import it into the other devices and make any necessary minor changes, such as assigning a unique IP address to each device. Procedures for importing and exporting a configuration are in the File Management Functions section on page 28.
IN-tact 1101 Software Configuration Guide 7

Configuring the IN-tact 1101 Before You Begin
For security, the Web Server has a five-minute timeout by default. However, this can be changed during configuration to be up to an hour. You can also completely disable the timeout feature. It is suggested that you gather all configuration information, such as terminal CU addresses, host processor configuration, IP address,etc. before you begin the configuration process. If there is no activity within a four-minute period, the following warning appears:

NOTE: If you have multiple applications open, it is possible that the warning may not appear in your
foreground and could be hidden behind another window. We recommend keeping the Web Server interface maximized on your screen.
If you click OK in the warning, the timer resets and a new five-minute “no activity” countdown begins. The warning remains for one minute. If you do not acknowledge it within that time, your session expires and the following message appears:

You are now required to log in to the device again. If you time out due to no activity during the configuration process, your settings are not saved and you will have to start over. If you are viewing the online Help, the session timer continues to run.
The IN-tact 1101 automatically logs you out of the Web Server interface when you close the browser window. However, if the web session timeout feature is disabled, the session remains open. For example, if you browse to other sites while configuring the IN-tact 1101, it may appear that another session is already in progress when you return to the IN-tact's address.
It is important to understand that only one user may be logged in to the IN-tact 1101 Web Server interface at any given time. For example, assume that User 1 has already logged in and has a session in progress. When User 2 attempts to log in, the IN-tact Login screen displays with a red message stating "Another user is logged in. If you continue, their session will expire immediately." If User 2 continues to enter the password and log in at this point, User 1 is logged off and that session is closed. A new session is started for User 2. User 1 will see a message stating "Your session is no longer valid. Please log in again." when they select a screen. Any changes made by User 1 that have not been saved with Apply and Restart are discarded.

Before You Begin Configuring the IN-tact 1101
You must determine whether to use static IP addressing or DHCP-assigned IP addressing. This is important because the unit is set to seek a DHCP address by default.
Before configuration, the IN-tact 1101 automatically tries to obtain a DHCP address three times when first powered on. If a DHCP address is not found, the unit reverts to and operates at its default static IP address of “192.168.1.20”.
NOTE: After configuration, if the DHCP option is enabled, the IN-tact 1101 will never fall back to a static
IP address. It will always seek a DHCP address.
The default IP address is valid until you configure the IN-tact 1101. It is assumed that you will assign an IP address during configuration (or leave DHCP enabled). Make note of the new assigned IP address. It is a good idea to write the IP address on a label or tag and physically attach it to the unit for future reference. If you need to reconfigure the unit at some point in the future, use the assigned IP address, not the default IP address. If the IP address is lost or becomes unknown, the only way to reconfigure the unit is to reset it to configuration defaults, which will restore the default IP address. However, you will also have to reconfigure all IN-tact 1101 settings if you reset it to configuration defaults.
If you are using DHCP to assign addresses on your network, contact your DHCP administrator to obtain the IP address for this unit, based on its MAC address. The unit’s MAC address is located on the serial number tag on the bottom of the unit. In most cases, a particular IP address should have already been reserved for the unit and that IP address should be used to contact the unit for configuration.
If a random DHCP IP address is assigned, you must determine what IP address has been assigned to the IN-tact 1101 in order to contact it for configuration. This will have to be done through DHCP, you cannot determine a randomly assigned IP address from the IN-tact 1101.
At a minimum, you are required to configure at least one host address with a valid IP address or URL and one terminal. Otherwise, an error message indicating an “invalid configuration” appears when you attempt to save the configuration. Error messages will continue to appear, informing you of what is needed, until you have configured at least the minimum the IN-tact 1101 needs to operate. In general, validation of individual entries is not performed; you need to check your entries to make certain they are correct.
IN-tact 1101 Software Configuration Guide 9

Configuring the IN-tact 1101 Configuration Procedure
You will need the following in order to configure the IN-tact 1101:
Windows 2000 Service Pack 3 or higher should be installed on the computer being used to configure the IN-tact.
In general, do not use the "double-quote" special character (like the one surrounding the word) in data entry fields. It is not recognized as a valid character by the IN-tact 1101. The exception to this is within dial strings. The double-quote character can be used with no problem when being defined as part of a dial string.
Some browser settings can cause extra system messages to appear and cause other issues. The following items are suggestions for browser setup while configuring the IN-tact 1101:
Use this procedure when you are ready to configure the IN-tact 1101. If you have not already done so, please read the preceding section before beginning any configuration.
To configure the IN-tact 1101:

Configuration Procedure Configuring the IN-tact 1101
(direct connection to the PC requires a crossover Ethernet cable). Connection to a terminal or terminal network is not required in order to configure the device. 2. Apply power to the IN-tact 1101 and power on your PC. By default, the IN-tact 1101 seeks a DHCP IP address. Both LEDs on the LAN port will flash in short intervals as the unit seeks a DHCP IP address. This takes about 15 seconds. 3. On your PC, open the Internet browser (Microsoft Internet Explorer 5.0 or higher). 4. In the browser address bar, type the IN-tact 1101 IP address (either DHCP assigned or the default static address of 192.168.1.20). 5. Press Enter. The IN-tact 1101 responds with the following message:

IN-tact 1101 Software Configuration Guide 11

Configuring the IN-tact 1101 Configuration Procedure

This window is displayed by Internet Explorer and allows you to view certificate details and install a certificate on your computer.
To install the Hypercom certificate on your machine, click Install Certificate and follow the instructions presented by the Import Certificate wizard.


Configuration Procedure Configuring the IN-tact 1101

NOTE: You must set the password within the five-minute time period; it is suggested you do so
immediately. If the time limit expires, you will have to reset the device in order to log in.
IN-tact 1101 Software Configuration Guide 13

Configuring the IN-tact 1101 Configuration Procedure
Password guidelines:
To change the password:

At this point, you can use the navigation tree on the left side of the screen to go to any of the configuration screens. Each screen and the entries you should make are explained in the following pages.

Navigation Configuring the IN-tact 1101
The IN-tact 1101 configuration navigation tree is easy to understand; its operation is similar to Internet Explorer and other like applications. Shown below are examples of the navigation tree in its initial state of completely collapsed, fully expanded, and a subset of the configuration screens.
Navigation Tree Collapsed Navigation Tree Expanded Configuration Screens



IN-tact 1101 Software Configuration Guide 15

Configuring the IN-tact 1101 Using the Toolbar
A toolbar displays near the upper-right corner of each IN-tact 1101 screen. Only the buttons applicable to the selected screen display.

For example, most configuration screens display both an Apply and Restart button and a Save and Continue button. Read-only screens, like Overview, display only a Help and Print button.
It is important to understand how the buttons work and which one you should use in a particular situation. The purpose and difference between apply and restart and save and continue is explained below.
In a few cases, like changing passwords and event logging settings, this button is labeled Apply rather than Apply and Restart. In these cases, your changes are applied immediately and you do not have to restart the device. However, all configuration changes require that the changes first be written to persistent memory, then the device restarted, in order for your changes to become effective.
NOTE: On screens that feature advanced or related options on a second screen, any changes made on
the first screen are temporarily saved when you click Edit or Advanced to access the second screen. You must still use Apply and Restart in order to write the changes to persistent memory.

Configuration Screens Configuring the IN-tact 1101
The Overview screen is your starting point on the IN-tact 1101 and appears whenever you log in to the device or click Overview on the navigation tree. It provides a quick overview of current settings, along with identification information to help you confirm that you are connected to the correct device. The Overview screen is read only; there are no fields or required entries. Some of the information shown here is the result of your setting on other screens.
IN-tact Model Hypercom model number of the unit. This number is important because there are several models within the IN-tact product series. This number cannot be changed.
Description Free-form description of the IN-tact device. This information comes from the System Settings screen and can be as descriptive as you wish.
Device ID A free-form alphanumeric value (up to 32 characters) entered on the System Settings screen to help identify this IN-tact 1101 from others on your network. Each IN-tact 1101 should be assigned a unique Device ID.
Location This is the physical location or point of installation for this device, such as “South Phoenix Store” or “Store 632”. This information is entered on the System Settings screen.
IN-tact 1101 Software Configuration Guide 17
Field Description

Configuring the IN-tact 1101 Configuration Screens
Contact This can be the name of the administrator, support group, help desk, or other entity to contact for information about this configuration.This information is entered on the System Settings screen.
MAC Address Current MAC address of the IN-tact 1101. This is not normally changed, but can be configured on the Ethernet Port Settings screen.
IP Address Current IP address of the IN-tact 1101. The IP address is set on the Ethernet Port Settings screen.
IP Gateway Configured IP address of the IP gateway router if using static addressing; learned IP gateway address if using DHCP. If you need to change this setting, go to the Ethernet Port Settings screen.
DNS Server The current DNS server in use. A static DNS server can be configured if DHCP is not being used. If you need to change this setting, go to the Ethernet Port Settings screen.
Field Description

Configuration Screens Configuring the IN-tact 1101
On the navigation tree, click IN-tact Setup > System Setup > System. The System Settings screen appears:

This screen is used to configure basic information about the IN-tact 1101. Entries on this screen also appear on the Overview screen.
Description Use this field to define the device type (IN-tact 1101) or its purpose, such as "IP gateway for POS network." The information you decide to include here is up to you; up to 32 characters are accepted.
Device ID Enter a unique identifier for the device. This is a free-form alphanumeric value of up to 32 characters, including spaces. An entry is required here; you cannot leave the Device ID blank or use only a space as an entry.
Location Enter the physical location or point of installation for this device, such as “South Phoenix Store” or “Store 632”. Up to 256 characters are accepted.
Contact Enter the name of the administrator, support group, help desk, or other entity that can be contacted for information about this configuration. You might want to include a phone number or email address here. Up to 256 characters are accepted.
NOTE: Click Save and Continue or Apply and Restart as appropriate. Keep in mind that your changes
are not written to persistent memory until you click Apply and Restart.
IN-tact 1101 Software Configuration Guide 19

Configuring the IN-tact 1101 Configuration Screens
On the navigation tree, click IN-tact Setup > System Setup > Ethernet Port. The Ethernet Port Settings screen appears:

Use this screen to set basic communication parameters for the Ethernet Port on the IN-tact 1101. Only IP version 4 is supported. The MAC address can be changed in the rare event that MAC address filtering or other firewall issues are preventing the provided MAC address from working correctly. If not using DHCP, you are required to configure a valid IP address for the IN-tact 1101 to be operational. You cannot permanently save the configuration until you do so.
MAC Address Unique address of this IN-tact 1101.
Static IP Address Change to match the IP addressing requirements for your network. By default, DHCP is enabled and this field displays “192.168.1.20”.
Static Subnet mask Change to match the local IP subnet of your network. The default is 255.255.255.0.
Static Gateway Address Enter the gateway address used to route IP off the local subnet. The default is 0.0.0.0.
Static DNS Server Enter the IP address of the DNS server that should be used.
Enable DHCP Enabled by default. Click to disable DHCP and use a static IP address. If DHCP is enabled, both of the LEDs on the LAN connector of the IN-tact 1101 will flash in unison when the device is powered on and is attempting to acquire an IP address.
NOTE: Click Save and Continue or Apply and Restart as appropriate. Keep in mind that your changes
are not written to persistent memory until you click Apply and Restart. Any changes made on this screen are temporarily saved when you click Advanced to access the second screen. You must still use Apply and Restart in order to write the changes to persistent memory.

Configuration Screens Configuring the IN-tact 1101
On the navigation tree, click IN-tact Setup > System Setup > Ethernet Port > Advanced. The Ethernet Port Advanced Settings screen appears:

Several additional settings are available by clicking Advanced on the Ethernet Port Settings screen. These settings can be used to “fine tune” IN-tact 1101 performance on your network.
Keep Alive Use this checkbox to enable or disable the keep alive features of the IN-tact 1101. This feature is enabled by default.
During keep alive operation, the IN-tact 1101 holds an established connection open for specified amount of time before automatically disconnecting.
When enabled, the IN-tact 1101 sends a keep alive message on each host connection at intervals set by the keep alive timer.
Keep Alive Timer (seconds) Enter the value (in seconds) between keep alive messages set to the host. Five seconds is the minimum, 600 seconds is the maximum. Thirty seconds is the default value.
TCP Window Size Use the drop-down list to select the size of the TCP window to be used. Choose a value between 2KB and 8KB. The default value is 2KB.
Number of Session Retransmits Use the drop-down list to select the number of retransmissions allowed during a session. The default value is 4 and should not be changed.
IN-tact 1101 Software Configuration Guide 21

Configuring the IN-tact 1101 Configuration Screens
Session Inactivity Timeout (seconds)
Use the up and down arrows to set the number of seconds a session should remain active after no activity is detected. The default is 15 seconds. The minimum setting is five seconds, the maximum is 256 seconds.
Restrict Source Port Range Use this checkbox to enable or disable restricting the range of source port values for on-demand TCP connections. By default, source port values range from 1024 through 65534. Enabling this option restricts the source port values to the range of 1024 through 1039. Restriction is disabled by default.
NOTE: Click Save and Continue or Apply and Restart as appropriate. Keep in mind that your
changes are not written to persistent memory until you click Apply and Restart.

Configuration Screens Configuring the IN-tact 1101
On the navigation tree, click IN-tact Setup > System Setup > Security. The Security Settings screen appears:
This screen is used to set IN-tact 1101 security features. It also appears the first time you log in to the device with the default password. If you have already set the password, you can skip this screen and continue with configuration.
You can change the IN-tact 1101 password whenever necessary. There is one default user name for log in (admin) and it cannot be changed. There is no default time period for password expiration; the password you set remains valid until it is changed.
Password guidelines:
To change the password:
1. Type the current password in the Old Password field. For security purposes, your entry will appear as a series of asterisks. 2. Type the new password in the New Password field. It must be at least eight characters. 3. Type the new password again in the Retype New Password field to confirm. 4. Click Apply to temporarily save your settings. Your changes are immediately written to persistent memory. The new password is in effect the next time you log in to the IN-tact 1101.
IN-tact 1101 Software Configuration Guide 23

Configuring the IN-tact 1101 Configuration Screens
On the navigation tree, click IN-tact Setup > System Setup > Web Interface. The Web Interface Settings screen appears:

You have the option of restricting access to the IN-tact 1101 web server to a specific IP address (or range of addresses). This is useful in preventing unauthorized access attempts on the device from IP addresses outside your normal range of operation.
You can also disable or change the value of the timeout feature associated with the web interface. This is a security feature. By default, the web session automatically expires after five minutes of no activity. The user is logged out. Any changes made to that point are discarded, unless Apply and Restart has been used to commit the changes to persistent memory. However, there may be situations in which you want to disable the timeout completely, or set it to a different value. For example, a direct "always on" connection to the web server, or while working with or configuring the device.
The IN-tact 1101 automatically logs you out of the web server interface when you close the browser window. However, if the web session timeout feature is disabled, the session remains open. For example, if you browse to other sites while configuring the IN-tact 1101, it may appear that another session is already in progress when you return to the IN-tact's address.
It is important to understand that only one user may be logged in to the IN-tact 1101 web server interface at any given time. For example, assume that User 1 has already logged in and has a session in progress. When User 2 attempts to log in, the IN-tact Login screen displays with a red message stating "Another user is logged in. If you continue, their session will expire immediately." If User 2 continues to enter the password and log in at this point, User 1 is logged off and that session is closed. A new session is started for User 2. User 1 will see a message

Configuration Screens Configuring the IN-tact 1101
stating "Your session is no longer valid. Please log in again." when they select a screen. Any changes made by User 1 that have not been saved with Apply and Restart are discarded.
Restrict Access to Web Server Use this checkbox to enable a specific range of IP addresses that will be able to contact the Web Server application.
IP Address 1 Enter the first IP address that will be able to access the Web Server.
Subnet Mask Enter the corresponding subnet mask for IP address 1. In order to restrict access to only a single IP address, use a mask of 255.255.255.255.
IP Address 2 Enter the second IP address that will be able to access the Web Server.
Subnet Mask Enter the corresponding subnet mask for IP address 2.
Expire Inactive Web Sessions Use this checkbox to enable or disable the inactivity timeout feature. This is not a dynamic change; you must Apply and Restart in order for this change to take affect.
Inactivity Timeout Set the value (in minutes) for how long a web session should stay active with no activity. The default value is 5 minutes. Valid entries are from 5 to 60 minutes.
NOTE: Click Save and Continue or Apply and Restart as appropriate. Keep in mind that your
changes are not written to persistent memory until you click Apply and Restart.
IN-tact 1101 Software Configuration Guide 25

Configuring the IN-tact 1101 Configuration Screens
On the navigation tree, click IN-tact Setup > System Setup > SNMP Interface. The SNMP Interface Settings screen appears:

SNMP management of the IN-tact 1101 is optional. The device is capable of hosting two separate SNMP sessions. Use this screen to configure the IP address for each of the sessions. Trap forwarding is optional and can be used independently of SNMP management.
Enable SNMP Agent Use this checkbox to enable or disable the SNMP agent.
Manager Address 1 Enter the IP address of the first SNMP manager. Set the checkbox to enable or disable communication with this SNMP manager.
Manager Address 2 Enter the IP address of the second SNMP manager. Set the checkbox to enable or disable communication with this SNMP manager.
Trap Destination 1 Enter the first IP address to which the IN-tact 1101 should forward trap information. Set the checkbox to enable or disable trap forwarding to this address.
Trap Destination 2 Enter the second IP address to which the IN-tact 1101 should forward trap information. Set the checkbox to enable or disable trap forwarding to this address.
Read Only Community Enter the SNMP Read Only community string.
Read Write Community Enter the SNMP Read Write community string.
Click Save and Continue or Apply and Restart as appropriate. Keep in mind that your changes are not written to persistent memory until you click Apply and Restart.

Configuration Screens Configuring the IN-tact 1101
On the navigation tree, click IN-tact Setup > System Setup > Dial Backup. The Dial Backup Settings screen appears:

The IN-tact 1101 features dial backup capability in the event of ISP (or other) outage that affects the ability to process transactions via the device's Ethernet port. A compatible modem must be physically connected to Port 1 (RS-232) on the IN-tact 1101 and a working telephone line connected to the modem in order to use the dial backup feature. Supported modems include:
IN-tact 1101 Software Configuration Guide 27

Configuring the IN-tact 1101 Configuration Screens
Other models of modems may also work with the IN-tact 1101. However, unlike supported modems, certain status screens may not accurately reflect correct values.
Within the IN-tact 1101, availability of the Ethernet port is constantly monitored. Once dial backup is enabled, any outage of the Ethernet port lasting longer than 5 seconds automatically triggers the IN-tact 1101 to switch to dial backup mode. Likewise, dial backup is automatically disconnected (based on a period of inactivity you specify) once the Ethernet connection is restored.
This screen allows you to configure basic modem operation. Use the Advanced button to display additional modem configuration options.
Enable Dial Backup Click this checkbox to enable dial backup operation. By default, this operation is disabled.
AT Initialization String Enter the initialization string for your modem. This string is sent to the modem every time dial backup starts. This string is sent to the modem every time dial backup starts. Up to 128 characters are accepted in this field. At a minimum, you must specify at least the command AT here; you cannot have a blank initialization string. The IN-tact 1101 looks for the response to the attention command to determine the modem's current state. Also, the IN-tact expects a numeric response. You must include the command V0 in your initialization string to require a numeric response from the modem.
Consult the manufacturer's documentation for your specific modem to determine the command set being used and what commands are accepted by the modem. Reset to Default can be used to reset the initialization string to the default US Robotics modem setting of:
If you are using a Hayes or ZOOM modem, the initialization string should be set to:
AT Hang Up String This is similar to the initialization string, except this command string is sent to the modem to cause it to hang up. Enter the hang up string for your modem. Up to 20 characters are accepted in this field. Consult the manufacturer's documentation for your specific modem to determine the command set being used and what commands are accepted by the modem. Reset to Default can be used to reset the hang up string to the default setting of “ATH0”. This default can be used for all supported modem types. Any additional commands you want to add to the string should be placed after the AT and before the H0. Any commands entered as part of the Hang Up string are automatically prefixed with “+++”.
Enable Primary Dial Click this checkbox to enable the primary dial string. This is the first host processor that the modem will attempt to contact in the event of an Ethernet outage.
Primary AT Dial String Enter any commands and the phone number to dial in order for the modem to establish contact with the primary host processor. Up to 32 characters are allowed in this field. This string must begin with ATDT (or ATDP for pulse dialing).

Configuration Screens Configuring the IN-tact 1101
Authentication Methods Allowed Click the CHAP and PAP checkboxes as necessary to match the authentication being used with this host processor. Both are enabled by default.
User Name/Password If authentication is being used, enter both the User Name and Password to be transmitted in the appropriate fields.
Retype Password Type the password again in the Retype Password field to confirm the password.
Enable Alternate Dial Click this checkbox to enable an alternate dial string. The IN-tact 1101 will automatically attempt to contact this host processor if the primary modem connection is busy or unanswered.
Alternate AT Dial String Enter any commands and the phone number to dial in order for the modem to establish contact with the alternate host processor. Up to 32 characters are allowed in this field. This string must begin with ATDT (or ATDP for pulse dialing).
NOTE: Click Advanced, Save and Continue or Apply and Restart as appropriate. Keep in mind that
your changes are not written to persistent memory until you click Apply and Restart. Any changes made on this screen are temporarily saved when you click Advanced to access the second screen. You must still use Apply and Restart in order to write the changes to persistent memory.
IN-tact 1101 Software Configuration Guide 29

Configuring the IN-tact 1101 Configuration Screens
On the navigation tree, click IN-tact Setup > System Setup > Dial Backup >Advanced. The Advanced Dial Backup Settings screen appears:

This screen allows you to set several advanced options associated with the dial backup feature. You can specify how long the modem will stay connected with no activity and how often the IN-tact 1101 checks to see if the Ethernet connection has been re-established. You can also control whether dial backup is established immediately upon Ethernet outage or only when a transaction is present from one of the terminals and needs to be processed. Finally, you can control whether or not terminal downloads are accepted while operating in dial backup mode. Because terminal downloads can be lengthy over a modem, you may prefer to allow these only when connected via Ethernet.

Configuration Screens Configuring the IN-tact 1101
Inactivity Disconnect Timer Use the Hours and Minutes fields to specify the amount of time you would like the IN-tact 1101 to hold the modem connection open after the last transaction was processed. The modem will automatically disconnect after the time you specify here transpires. By default, this is set to five minutes. The valid range of entries is between zero minutes and 24 hours. Setting this value to zero disables the timer and the modem will stay indefinitely connected, regardless of the status of the Ethernet connection. You will have to manually disconnect the modem in this case. The value of Inactivity Disconnect Timer (if not set to zero) must be greater than that of Ethernet Retry Timer.
Ethernet Retry Timer Use the Hours and Minutes fields to set how often the IN-tact 1101 should retry the Ethernet connection while operating in dial backup mode. If the Ethernet connection has been re-established, the IN-tact 1101 closes the modem connection and reverts to normal IP-based transaction processing as soon as the Inactivity Disconnect Timer expires. By default, the IN-tact 1101 rechecks the Ethernet connection every minute. The valid range of entries is between 1 and 1439 minutes.
Dialing Mode Use the drop-down list to select whether the IN-tact 1101 begins establishing a modem connection immediately upon Ethernet outage, or waits until a transaction has been generated (default).
Allow Terminal Program Downloads
Click this checkbox to enable terminal program downloads while operating in dial backup mode. By default, this option is enabled. However, because terminal downloads can take some time to complete, you may not want them to occur during dial sessions, only via IP sessions.
NOTE: Click Back, Save and Continue or Apply and Restart as appropriate. Keep in mind that your
changes are not written to persistent memory until you click Apply and Restart.
IN-tact 1101 Software Configuration Guide 31

Configuring the IN-tact 1101 Configuration Screens
On the navigation tree, click IN-tact Setup > System Setup > Time. The Time Settings Screen appears:

Use this screen to enable and configure SNTP timekeeping on the IN-tact 1101. If enabled, you will not be able to set system time for the device on the Set System Time screen. Instead, the IN-tact 1101 will keep time according to an NTP server.

Configuration Screens Configuring the IN-tact 1101
Enable SNTP Click this checkbox to enable SNTP, the device will automatically obtain current time from a SNTP server on the network. You must Apply and Restart before this change will become effective. SNTP is disabled by default.
Time Zone Use this panel to select the time zone where the IN-tact 1101 is located. This is necessary for the device to correctly calculate local time based on the UTC time received from NTP server(s). Daylight saving time is automatically calculated based on your time zone choice. The default time zone is Arizona (GMT - 07:00).
NTP server(s) provided by DHCP If DHCP is enabled and the IN-tact 1101 obtained NTP server information from it, the first two NTP servers are displayed here and are available for time synchronization.
Search NTP servers in this order Use this panel to define the preferred search order for NTP servers. Servers are contacted in the order you select. The default search order is DHCP first, then statically-configured.
Static Configuration for NTP Servers
You have the option of configuring up to two NTP servers -- a primary and an alternate. The value entered can be an IP address or a domain name.
Interval (hours) Time is synchronized on start-up, then periodically according to the interval configured you specify in this panel. The interval is specified in hours, from 1 through 24, with 24 being the default. Time synchronization can be requested whenever necessary by clicking Synchronize Now. This button is only present if you have enabled SNTP and restarted the device. A message displays to inform you that the time synchronization process can take up to 40 seconds as a valid NTP server is contacted. The result (failure or success) is displayed on this page. An SNMP trap is generated when start-up time synchronization fails. After that, a failed synchronization attempt generates an event with no SNMP trap. If successful, the new time is also displayed. A successful manual synchronization resets the synchronization interval. In other words, the countdown until next synchronization is reset to zero at the time you click Synchronize Now. If you are using a SNMP manager to set time synchronization, set your SNMP manager timeout to be at least 45 seconds to allow adequate time for this operation to take place. Time will be synchronized with the first server that successfully responds to the request. An event is recorded stating that time has been successfully synchronized, including the IP address of the NTP server that responded to the time request.
NOTE: Click Save and Continue or Apply and Restart as appropriate. Keep in mind that your changes
are not written to persistent memory until you click Apply and Restart.
IN-tact 1101 Software Configuration Guide 33
Time Zone Configuration · Time Synchronization Interval

Configuring the IN-tact 1101 Configuration Screens
On the navigation tree, click IN-tact Setup > Application Setup > Terminal Port. The Terminal Port Settings screen appears:

Use this screen to set the communication parameters for connection to your HLAN terminal network. Your settings here should match the configuration of your terminal network. You are required to configure at least one terminal for the IN-tact 1101 to be operational. You cannot permanently save the configuration until you do so.
HLAN Speed Use the drop-down list to select either 19200bps (default) or 4800 bps. The speed selected should match speed set in the terminals.
Enabled By default, all terminal addresses are disabled. Use this series of checkboxes to enable any terminal address not being used. You can also use this feature to temporarily disable a terminal that is not responding to poll if it is affecting network performance.
Description Type a brief text description of each terminal on the HLAN network, such as “Register 1”, “Drive-thru”, etc. 32 characters are accepted.
CU Address A listing of valid HLAN polling addresses. Make certain that the Enabled checkbox is selected and there is a description for each terminal address in use at this location. All unused addresses should be disabled so they are not polled.
NOTE: Click Save and Continue or Apply and Restart as appropriate. Keep in mind that your
changes are not written to persistent memory until you click Apply and Restart.

Configuration Screens Configuring the IN-tact 1101
On the navigation tree, click IN-tact Setup > Application Setup > Host Port. The Host Port Settings screen appears:

This is the first of three screens used to set up host processors. This screen consists of several fields that allow you to configure basic information for each of your host processing functions. Each row represents a unique NII for routing to a specific host function. For example, this could be card approval transactions or other functions like electronics receipt capture or biometrics. Up to eight different NIIs can be configured (some may be different functions provided by the same IP address). However, only the hosts to which the terminals will actually be forwarding information need to be defined.
When you have entered the information as described below, click Edit at the end of the row to display the second screen and complete addressing information for that processor. The next screen that appears depends on the connection type. There are different screens for Standard and HTTP.
The third screen displays when you click Edit on the second screen and allows you to define options for permanent or on-demand connection types.
To configure a new processor:
IN-tact 1101 Software Configuration Guide 35

Configuring the IN-tact 1101 Configuration Screens
transactions to a processor for troubleshooting purposes or other reasons. All IP addressing information remains intact. When you are ready to resume sending transactions to a processor you have disabled, click Enabled to resume normal operation. 4. There are three Connection Types - Standard, HTTP, and Merchant Link. Use the drop-down list to choose the appropriate type for this host processor, then click Edit at the end of the row.
NOTE: Click Save and Continue or Apply and Restart as appropriate. Keep in mind that your
changes are not written to persistent memory until you click Apply and Restart. Any changes made on this screen are temporarily saved when you click Edit to access the next screen. You must still use Apply and Restart in order to write the changes to persistent memory.
(Used when configuring connections not requiring HTTP protocol)
On the navigation tree, click IN-tact Setup > Application Setup > Host Port. Select Standard connection type and click Edit.

The IN-tact 1101 uses the addressing information entered here to route transactions to the appropriate destination. Both a primary and alternate IP address can be configured for each host processing function. Contact the host processor to obtain the correct IP and port address for routing if unknown.

Configuration Screens Configuring the IN-tact 1101
NII This is the NII routing code entered for this processor on the Host Port Settings screen. It is provided as a reminder of which processor you are currently working with.
Description This is the description (or name) entered for this processor on the Host Port Settings screen. It is provided as a reminder of which processor you are currently working with.
Connection Mode Select either Permanent or On Demand from the drop-down list. A permanent connection is "always on", while On Demand establishes a host connection only when there is a transaction present to process. Further options for the connection type can be defined by clicking the Edit button. The options that display depend on the connection type selected.
Enable SSL Use this checkbox to enable Secure Socket Layer (SSL) if the host requires this type of encryption.
Primary IP Address Enter the primary IP address or URL of the processor.
Primary TCP Port Enter the primary port address of the processor.
Alternate IP Address Enter the alternate IP address or URL of the processor. This is only used if the primary IP address cannot be reached.
Alternate TCP Port Enter the alternate port address of the processor.
NOTE: Click Back, Save and Continue or Apply and Restart as appropriate. Keep in mind
that your changes are not written to persistent memory until you click Apply and Restart. Any changes made on this screen are temporarily saved when you click Edit to access the next screen. You must still use Apply and Restart in order to write the changes to persistent memory.
IN-tact 1101 Software Configuration Guide 37

Configuring the IN-tact 1101 Configuration Screens
(Used when configuring connections requiring a permanent connection mode)
On the navigation tree, click IN-tact Setup > Application Setup > Host Port. Click Edit, then select a permanent connection type. Click Edit again.

This screen provides an option for how transaction headers are handled for permanent connection types. The Hypercom POS LAN Header and TPDU are required for permanent connections. The only option is whether or not the length field should be included as part of the length calculation. Contact the host processor to obtain the correct settings for this option if unknown.
NII This is the NII routing code entered for this processor on the Host Port Settings screen. It is provided as a reminder of which processor you are currently working with.
Description This is the description (or name) entered for this processor on the Host Port Settings screen. It is provided as a reminder of which processor you are currently working with.
Include Length Field in Length Calculation
The first two bytes of the POS LAN header are a length indicator. This option determines whether or not these first two bytes are included as part of the length calculation. This option should be set to match host processor configuration.
Click Back, Save and Continue or Apply and Restart as appropriate. Keep in mind that your changes are not written to persistent memory until you click Apply and Restart. Any changes made on this screen are temporarily saved when you click Edit to access the next screen. You must still use Apply and Restart in order to write the changes to persistent memory.

Configuration Screens Configuring the IN-tact 1101
(Used when configuring connections requiring a on demand connection mode)
On the navigation tree, click IN-tact Setup > Application Setup > Host Port. Click Edit, then select an on-demand connection type. Click Edit again.

This screen allows you to further define options for an on demand connection type. Options include how transaction headers and certain protocol settings are handled by the IN-tact. You may need to change these settings for hosts that use different framing or protocol options. Contact the host processor to obtain the correct settings for these options if unknown.
NII This is the NII routing code entered for this processor on the Host Port Settings screen. It is provided as a reminder of which processor you are currently working with.
Description This is the description (or name) entered for this processor on the Host Port Settings screen. It is provided as a reminder of which processor you are currently working with.
Include Two-byte Message Length Header
Use this checkbox to include a two-byte message length indicator if required for this host connection. This option is disabled by default. The two options below allow further control of the header and should be enabled or disabled according to how the host processor is configured.
Include Length Field in Length Calculation
As mentioned above, the first two bytes of the POS LAN header are a length indicator. This option determines whether or not these first two bytes are included as part of the length calculation. This option should be set to match host processor configuration.
Include TPDU The TPDU is the next five bytes of the POS LAN Header and includes information used for routing purposes. This option determines whether or not these five bytes are included as part of the header. This option should be set to match host processor configuration.
IN-tact 1101 Software Configuration Guide 39

Configuring the IN-tact 1101 Configuration Screens
Use STX/ETX Wrapper Use this checkbox to enable Start of Text (STX) and End of Text (ETX) wrappers if required by the host. This option is used primarily for hosts that don't run Visa protocol, but want to use async framing.
Discard ACKs Use this checkbox to discard any ACKs sent by the terminals, rather than sending them to the host. This option is used primarily for hosts that don't run Visa protocol, but want to use async framing.
Click Back, Save and Continue or Apply and Restart as appropriate. Keep in mind that your changes are not written to persistent memory until you click Apply and Restart. Any changes made on this screen are temporarily saved when you click Edit to access the next screen. You must still use Apply and Restart in order to write the changes to persistent memory.

Configuration Screens Configuring the IN-tact 1101
(Used when configuring connections requiring HTTP protocol)
On the navigation tree, click IN-tact Setup > Application Setup > Host Port. Select HTTP Connection Type and click Edit.

The IN-tact 1101 uses the addressing information entered here to route transactions to the appropriate destination. Both a primary and alternate IP address or URL can be configured for each host processing function. Contact the host processor to obtain the correct IP and port address for routing if unknown.
NII This is the NII routing code entered for this processor on the Host Port Settings screen. It is provided as a reminder of which processor you are currently working with.
Description This is the description (or name) entered for this processor on the Host Port Settings screen. It is provided as a reminder of which processor you are currently working with.
Enable SSL Use this checkbox to enable Secure Socket Layer (SSL) if the host requires this type of encryption.
Include Two-byte Message Length Header
Use this checkbox to enable Hypercom's proprietary POS LAN header if required for this host connection. This option is disabled by default. The two options below allow further control of the header and should be enabled or disabled according to how the host processor is configured.
IN-tact 1101 Software Configuration Guide 41

Configuring the IN-tact 1101 Configuration Screens
Include Length Field in Length Calculation
As mentioned above, the first two bytes of the POS LAN header are a length indicator. This option determines whether or not these first two bytes are included as part of the length calculation. This option should be set to match host processor configuration.
Include TPDU The TPDU is the next five bytes of the POS LAN Header and includes information used for routing purposes. This option determines whether or not these five bytes are included as part of the header. This option should be set to match host processor configuration.
Use STX/ETX Wrapper Use this checkbox to enable Start of Text (STX) and End of Text (ETX) wrappers if required by the host. This option is used primarily for hosts that don't run Visa protocol, but want to use async framing.
Discard ACKs Use this checkbox to discard any ACKs sent by the terminals, rather than sending them to the host. This option is used primarily for hosts that don't run Visa protocol, but want to use async framing.
Primary Host Address Enter the primary IP address or URL of the processor. Up to 2048 characters can be entered in this field.
Primary Port Enter the primary port address of the processor.
Alternate Host Address Enter the alternate IP address or URL of the processor. Up to 2048 characters can be entered in this field. This is only used if the primary IP address cannot be reached.
Alternate Port Enter the alternate port address of the processor.
transactions, such as POS credit and debit authorizations. If you require support for multiple and batch-type transactions, you should determine the availability of extended support within the HTTP host server gateway before configuring the IN-tact to use HTTP protocol.
Click Back, Save and Continue or Apply and Restart as appropriate. Keep in mind that your changes are not written to persistent memory until you click Apply and Restart.

Configuration Screens Configuring the IN-tact 1101
(Used when configuring connections that require a Merchant Link gateway)
On the navigation tree, click IN-tact Setup > Application Setup > Host Port. Select Merchant Link connection type and click Edit.

The IN-tact 1101 uses the addressing information entered here to route transactions to the appropriate destination. Both a primary and alternate IP address or URL can be configured for each host processing function. Contact the host processor to obtain the correct IP and port address for routing if unknown.
NII This is the NII routing code entered for this processor on the Host Port Settings screen. It is provided as a reminder of which processor you are currently working with.
Description This is the description (or name) entered for this processor on the Host Port Settings screen. It is provided as a reminder of which processor you are currently working with.
Include TPDU The TPDU is five bytes of the POS LAN Header and includes information used for routing purposes. This option determines whether or not these five bytes are included as part of the header. This option should be set to match host processor configuration.
Primary Host Address Enter the primary IP address or URL of the processor. Up to 2048 characters can be entered in this field.
Primary TCP Port Enter the primary TCP port address of the processor.
Alternate Host Address Enter the alternate IP address or URL of the processor. Up to 2048 characters can be entered in this field. This is only used if the primary IP address cannot be reached.
Alternate TCP Port Enter the alternate TCP port address of the processor.
IN-tact 1101 Software Configuration Guide 43

Configuring the IN-tact 1101 Configuration Screens
Click Back, Save and Continue or Apply and Restart as appropriate. Keep in mind that your changes are not written to persistent memory until you click Apply and Restart.
On the navigation tree, click IN-tact Setup > Application Setup > Transaction Processing. The Transaction Settings screen appears:

This screen is used to define various parameters the IN-tact 1101 uses to route transactions and communicate with host processors.
Default NII Enter the value of the NII to be used for default transaction routing. The value you enter here must match one of the hosts defined on the Host Port Settings screen or you will not be allowed to permanently save the configuration.
Routing Mode for Known NIIs Use the drop-down list to select whether transactions are routed to the host based upon the NII embedded within the transaction, or are routed to the default NII specified above. Note: Selecting the “Route to default NII” option will route all transactions to the default NII, regardless of other settings.
Routing Mode for Unknown NIIs Use the drop-down list to select whether unknown NIIs are routed to the default NII specified above, or are simply discarded when using embedded NII routing mode. Only applies to embedded NII, does not apply to default NII routing.
Send Initialization Requests to Use the drop-down list to select whether initialization requests are sent to the host, or instead sent to Term-Master.
Recognize Processing Code 92 As
Use the drop-down list to select whether you want code 92 to be recognized as an initialization request or treated as a transaction.
Recognize Processing Code 94 As
Use the drop-down list to select whether you want code 94 to be recognized as an initialization request or treated as a transaction.
NOTE: Click Save and Continue or Apply and Restart as appropriate. Keep in mind that your changes
are not written to persistent memory until you click Apply and Restart.

Each of the Control Panel screens and functions are explained in detail in this section.

As the name suggests, Control Panel functions allow you to control certain IN-tact 1101 operations. The screens within the Control Panel port of the navigation tree are:
IN-tact 1101 Software Configuration Guide 45

On the navigation tree, click Control Panel > File Management. The File Management Functions screen appears:

This screen is used to import and export files to/from the IN-tact 1101. This includes upgraded firmware, configuration files, and SSL certificates.
File Management Functions

Use this procedure to load and upgrade firmware for the IN-tact 1101. This process interrupts normal operations. The IN-tact 1101 will automatically reset and load the new firmware once loading is complete.
To load firmware:
1. Download the upgraded firmware to your local machine. Contact Hypercom for further information on firmware upgrades. 2. On the File Management Functions screen, click Browse (next to the Load Firmware field) to view a listing of the available firmware. 3. Navigate to and select the firmware upgrade file, then click Open. The path and filename now appear in the Upgrade Firmware field. 4. Click Load to install the new firmware on your IN-tact 1101. The file is copied to a custom partition on the IN-tact 1101. During the load process, a pop-up message appears informing you that the loading is in progress to the device cannot be access during the loading process.
If there is an error during the upgrade, the message “Firmware upgrade failed” appears in red below the field. Check that you have a valid image file (.img) or get a new copy of the file from the Hypercom website in case the file on your local machine is corrupted.
If the upgrade is successful, the IN-tact 1101 restarts.
This function allows you to save the custom image stored on the IN-tact 1101 to your local system. This is useful when you are preparing to upgrade and want to keep a copy of the image for backup purposes.
To export:
The firmware data is read directly from the custom partition in binary form and a temporary file is created.
IN-tact 1101 Software Configuration Guide 47
File Management Functions

This function allows you to load a configuration file from your local machine to the IN-tact 1101. This is useful in situations where you may be configuring several units. Rather than having to configure all of the IN-tact 1101 settings for each unit, you can simply load a previously exported configuration file that has the correct settings, then make any minor adjustments as necessary.
To load a configuration the IN-tact 1101:
If an error occurs while loading the file, a message in red appears below the field.
If successful, a message appears while the configuration file is loaded. When finished, the IN-tact 1101 restarts.
The old configuration file is saved as a backup configuration and the newly uploaded configuration file becomes the current configuration for the device.
NOTE: Only the items listed under IN-tact Setup are restored when a previous or imported configuration
is loaded. Passwords and Event Log settings are not imported with a configuration and must be set on each individual device.
This function allows you to save the current configuration stored on the IN-tact 1101 to your local machine.
To export a configuration to a PC:
The configuration file is prepared for download.
The file can now be loaded to other IN-tact units as needed and modified, or simply kept as a backup.
This function allows you to upload a new SSL certificate file to the user partition of the IN-tact 1101. Multiple user-imported SSL certificates can be stored and active (up to 16). The SSL certificates are only used for secure transactions (financial data traffic), not for the web interface itself. The certificate immediately becomes active; you do not need to restart the device.
File Management Functions

To load an SSL certificate:

There may be other sections and other data within the file. If the certificate is not in PEM format, then it must first be converted using OpenSSL (a freely available software package on the Internet) before the IN-tact 1101 can use it.
>> openssl x509 -hash -in mycert.pem -noout
The result will be an eight-character alphanumeric string, such as “557C3410”. The file must be renamed to add an extension of “.0”. In this case, the renamed file would be “557C3410.0”.
A red message appears if there is an error with this operation.
If the operation is successful, the certificate becomes active and the name of the file appears in this field. The certificate is now ready for use.
IN-tact 1101 Software Configuration Guide 49
File Management Functions

This function erases the selected SSL certificate file from the IN-tact 1101.
To delete an SSL certificate:
NOTE: The drop-down list and the Delete button are available only when certificates are present in the
system.
The certificate is physically erased from persistent memory. However, the certificate remains usable by the system until you restart or reset the device.
Use this function if you need to set up mutual authentication with a server. For mutual authentication, a reciprocal trust relationship must be established between the IN-tact and the server. The IN-tact must provide a client certificate containing its identity. The server must store a version of the certificate containing the client's identity and public key. This allows the server to trust the client during SSL mutual authentication.
You can load a single certificate and key combination on the IN-tact. This combination will be used for all SSL sessions that require mutual authentication. If the IN-tact is required to connect to two different hosts, each requiring mutual authentication, those two hosts must be able to accept the same certificate from the IN-tact.
Mutual authentication protects only transaction data, not configuration data.
Setting up the Client Key and SSL certificate on the IN-tact is a two-step process.
The certificate file is transferred to and loaded into the memory of the IN-tact. If the file cannot be read (because it is not in PEM format or because the password is invalid), an error is displayed on the web interface.
File Management Functions

On the navigation tree, click Control Panel > System Operations. The System Operations screen appears:

Use this screen to perform various reset functions on the IN-tact 1101.
Restart Device Click to perform a hardware reset of the IN-tact 1101. This is the same as a system reboot and causes the IN-tact 1101 to reload all configured information as if you powered off, then back on.
Restore to Previous Configuration
Click to reload the last known configuration. The IN-tact 1101 maintains a copy of the last known configuration as a backup. If you have made configuration changes and something is not working correctly, click this button to reload the last known configuration.
Return to Configuration Defaults Use this button to completely erase the current and backup configuration files. The IN-tact 1101 will then perform a restart. A new configuration file based on all of the default settings is built and used to load the unit.
This operation differs from “Revert to Factory Defaults” as no other files are affected. If you have upgraded firmware, it is untouched and still used. However, you will have to reset the password for the device.
IN-tact 1101 Software Configuration Guide 51
System Operations Screen

Restore to Factory Defaults Click to erase the current configuration, any upgraded firmware, and restore all settings to those as shipped from the factory.
WARNING: Use the previous two options only as the last resort! Performing these operations erases all IP addresses and other information and the IN-tact unit will have to be completely reconfigured before it can process any transactions. If the unit is in a remote location, it may be necessary to return it to the deployment center for reconfiguration. Enable DHCP is restored as is the default IP address of 192.168.1.20.
Enable HLAN Install Mode This is an optional mode of operation used for installation testing of connected terminals prior to making connections to the host processor. It allows you to verify the integrity of your HLAN and terminals before sending any live transactions to the host. Installation mode should always be disabled before beginning normal operations.
System Operations Screen

On the navigation tree, click Control Panel > Set System Time. The Set System Date/Time Function screen appears:

It is important to accurately set the time for the IN-tact 1101. Because some diagnostic functions, like event logging, use a wrap-around buffer to capture information, you will not be able to tell when specific events have occurred without a time reference. This is also important for SSL functions; the certificates will not be authenticated correctly.
The IN-tact 1101 does not have a battery to maintain time when power is removed. Time is lost after a power reset. The device, however, does include a feature to synchronize time with pre- configured servers using Simple Network Time Protocol (SNTP). See the System Setup > Time screen to enable and configure the use of SNTP.
Current Local Date/Time - This is a reference that indicates what date and time the IN-tact 1101 currently has set.
IMPORTANT - If not using SNTP, time must be reset after any restart of the device. Time on the IN-tact 1101 is only valid while the device is powered on and operating. In other words, if you power off or reset the device, time will have to be reset in order to be current. The IN-tact 1101 defaults the date and time to the date of the firmware build whenever time is reset.
IN-tact 1101 Software Configuration Guide 53
Set Date/Time Screen

On the navigation tree, click Control Panel > Clear Statistics. The Clear Statistics Function screen appears:

Use this screen to permanently remove all current statistical data from the IN-tact 1101. This can be useful when troubleshooting problems and you wish to collect fresh statistical data. When you click Clear All Statistics, a confirmation message displays. Clicking OK causes all statistical data to be permanently removed. Clicking Cancel leaves all statistical data unchanged.
NOTE: Clearing statistics does not interrupt normal operations.
Clear Statistics Screen

On the navigation tree, click Control Panel > Dial Backup. The Dial Backup Functions screen appears:

Dial backup operation is automatic when the IN-tact 1101 detects that transactions cannot be routed via the Ethernet port. However, you can also manually control dial backup operation using this screen. This can be useful for testing purposes, during planned outages for maintenance, or any other time you need to immediately control whether transactions are routed via IP or the modem. If you opt to manually begin dial operations, all of the timeout and trigger settings, such as the Inactivity Disconnect Timer (set on the Advanced Dial Backup Settings screen) are still in effect and will apply to dial operations.
Primary This is the dial string to reach the primary host processor. The dial string is set on the Dial Backup Settings screen.
Dial and Route Transactions over Dial Link
Click Dial to immediately dial the primary processor, establish connection, and begin routing transactions via the modem.
Dial and Continue Routing Transactions over Ethernet Link
Click Dial to immediately dial the primary/alternate host processor, but do not switch transaction routing from IP to modem. This is useful for testing purposes to make certain that the modem is working properly and connecting with the host processor specified in the primary/alternate dial string. If the Ethernet connection is lost while connected, transactions are automatically routed using the modem.
Alternate This is the dial string to reach the alternate host processor. The dial string is set on the Dial Backup Settings screen.
IN-tact 1101 Software Configuration Guide 55
Dial Backup

Dial and Route Transactions over Dial Link
Click Dial to immediately dial the alternate processor, establish connection, and begin routing transactions via the modem.
Disconnect Dial Click to disconnect the modem from either the primary or alternate host processor as soon as possible. If you are connected to the IN-tact via PPP (rather than the Ethernet interface) and click this button, you will be disconnected.
NOTE: Invoking the primary or alternate dial string causes web and SNMP traffic to use the modem. To
maintain communication with the IN-tact 1101, your web browser or SNMP manager must be configured to use the IP address of the dial port on the IN-tact device.
Dial Backup

Each of the IN-tact 1101 status functions are explained in detail in this section.

Status functions allow you to monitor IN-tact 1101 operations and view statistical information about transactions, response times, terminal activity, and uptime. This can be useful information when monitoring performance or when troubleshooting possible problems. The screens within the Status portion of the navigation tree are:
IN-tact 1101 Software Configuration Guide 57

On the navigation tree, click Status > System. The System Status screen appears:

This screen is divided into two sections. The upper portion of the screen provides important “at a glance” information to help you quickly determine whether the IN-tact 1101 and its associated terminals are up and operating correctly. The lower portion of the screen provides reference information about the firmware currently loaded and running on IN-tact 1101. You can use this information to check against the Hypercom web site to see if a newer version of firmware is available. New firmware can be installed by using the File Management function in Control Panel. Click Refresh as needed to update the status information on the screen.
System Status Screen

Current IN-tact 1101 Status:
Current Status There are two possible displays:
Not Configured: indicates that the IN-tact 1101 has not been properly configured. Go to System Setup and configure the device.
Current Mode Indicates whether the IN-tact 1101 is operating in “normal” mode or “install” mode.
Install mode is used to test terminal communications and should not be left on. Go to Control Panel > System Operations to disable install mode if it is on.
System Time Shows you the current time set for the IN-tact 1101.
Uptime Total time that the device has been powered on and operating.
Terminals Enabled Indicates the number of terminals configured. Terminals are configured on the Terminal Port Settings screen.
Terminals Active Indicates the number of configured terminals that are responding to poll and operating correctly. For more detailed information, see the Terminal Status screen.
Host Ports Enabled Indicates the number of host port connections that have been enabled.
Product Information:
Product Part Number Part number (the combination of hardware and software) of the IN-tact device
Platform Part Number Part number of the complete IN-tact 1101 without a firmware load
Serial Number Unique serial number of this IN-tact device
Hardware Part Number Part number of the base printed circuit board within the IN-tact 1101
Firmware Name Filename of the firmware currently loaded on the IN-tact 1101
Firmware Part Number Version of the firmware currently loaded on the IN-tact 1101
Build Date/Time When the firmware was compiled
Build Number Reference number assigned to the firmware
File Size (bytes) Actual size of the image file in bytes
IN-tact 1101 Software Configuration Guide 59
System Status Screen

On the navigation tree, click Status > Terminal Port. The Terminal Port Status screen appears:

This screen provides a table that allows you to quickly analyze the status of all enabled terminals and see response time measurements (RTM). From these, you can determine what your average (or normal) response time is over a period of time. No configuration is done here; all terminal configuration is done on the Terminal Port Settings screen. You can click Refresh as needed to update the status displayed on this screen.
Address Terminal’s CU (or polling) address
Description Description assigned in the Terminal Port Settings screen
Status Current status of the terminal, either Active, Idle, or No Response
Msg In Total number of messages received by the IN-tact 1101 from the terminal
Msg Out Total number of messages sent from the IN-tact 1101 to the terminal
RTM 0-2 Number of total transactions that were processed between zero and two seconds
RTM 2-4 Number of total transactions that were processed between two and four seconds
RTM 4-6 Number of total transactions that were processed between four and six seconds
RTM 6+ Number of total transactions that processing took longer than six seconds.
Terminal Port

Host Port Status Screen
On the navigation tree, click Status > Host Port. The Host Port Status screen appears:

This screen provides a table that allows you to quickly analyze the status of all enabled host processors. There are generally two entries for each host processor, one for the primary IP/URL and one for the alternate IP/URL. Click Refresh as needed to update the status.
NII NII number assigned to the host on the Host Processor Settings screen
Description Text description assigned to the host on the Host Processor Settings screen
Type Connection type, either Permanent or On Demand
Host Name Primary or Alternate host address configured in the Host Processor Settings screen. Either an IP address or URL. For long host names, place the mouse cursor on the Host Name field (hover) to display a pop-up tool tip that shows the complete URL host address.
Msg In Total number of messages received from the host processor by the IN-tact 1101
Msg Out Total number of messages sent from the IN-tact 1101 to the host processor
IN-tact 1101 Software Configuration Guide 61

Host Port Status Screen
Status Indicates the current status of the host processor. Valid status indications are color-coded and described below. Refer to the following table for the meaning of the most common failure codes.
Active — on demand connection Active SSL — on demand connection with SSL Connect — permanent connection Connect SSL — permanent connection with SSL Enabled — an idle on demand connection Failed — see error codes listed below Inactive — an idle permanent connection or an on demand connection that isn’t configured.
Interface Indicates the interface (Ethernet or PPP) that can be used to reach the host processor. If the host processor cannot be reached at all, “Unknown” is displayed here. When the host address is specified as a DNS name instead of an IP address, the initial interface appears as “Unknown”. Once a transaction has been routed to that host and the DNS server successfully resolves the host name, the interface type is then correctly shown as “Ethernet” or “PPP”.
100 DNS error The associated host name cannot be found by the Domain Name Server (DNS). This is because the DNS is not responding or it cannot find the name.
110 Socket creation error Internal socket creation error. Please refer to the Event Log for the specific failure.
120 General connection error The session cannot be connected to the host. Please refer to the Event Log for the specific reason.
121 Connection refused The session cannot be connected to the host because the host refused the connection. This generally means that the host application is not running or is not configured to use the TCP port.
122 Connection timed out The session cannot be connected to the host because the host did not respond. This generally means that the IP address for the host is wrong or the network is preventing the IN-tact 1101 from contacting the host.
130 General SSL error The session failed because of an SSL error. Please refer to the Event Log for the specific reason.
131 SSL certificate validation failed The session failed because the SSL certificate from the host could not be verified.
132 SSL timeout The session failed because the SSL negotiation did not complete within the required timeframe.
Code Description Explanation

On the navigation tree, click Status > Dial Backup. The Dial Backup Status screen appears:

Use this screen to determine the current status of dial backup operations. Three fields are of particular value when troubleshooting - Current Status, Primary Failure Code and Alternate Failure Code. Explanations of the status messages or codes that can be displayed in these fields are provided on the following pages to help you quickly diagnose any possible problems. Use Refresh to update the status/statistics displayed on this screen as necessary.
Current Status This field displays the current status of the modem as detected by the IN-tact 1101. Refer to Table 5-1 on page 64 for status message explanations.
Primary/Alternate Failure Code Refer to Table 5-2 on page 65 for failure codes and their explanations.
Current Mode Indicates the Dialing Mode setting on the Advanced Dial Backup Settings screen, either Immediate or Wait for Transaction.
Uptime Cumulative time that PPP has been connected.
IN-tact 1101 Software Configuration Guide 63
Dial Backup Status

Last Modem Connect Speed The last reported connection speed of the modem. This value is not reset when you clear statistics for the IN-tact 1101.
Inactivity Timer Disconnects The number of times the modem link was disconnected due to no transactions or inactivity.
Dial Attempts Total number of dial commands attempted.
Failed Dial Attempts Number of attempted dial commands that failed.
Failed Authentication Attempts Number of PPP negotiations that failed due to an invalid user ID or password.
Unexpected Disconnects Number of times the link was disconnected due to an unexpected condition or situation (cable being removed, power outage, etc.).
User Messages In Number of messages received from the host processor via the dial link. This does not include Ethernet or SNMP traffic.
User Messages Out Number of messages sent to the host processor via the dial link. This does not include Ethernet or SNMP traffic.
PPP IP Address The IP address assigned to the PPP interface.
Peer IP Address The IP address of the other end of the PPP link.
TABLE 5-1. Status Messages
Status Message SNMP Code Explanation
Dial Backup Feature Not Enabled 0 The feature is disabled by default. Go to the Dial Backup Settings screen to enable this feature.
Disconnected/Modem Not Present 1 The IN-tact 1101 was not able to detect a modem attached to the serial port (port 1). Check the modem cabling and power.
On Hook/Modem Present 2 The IN-tact 1101 was able to detect a modem. However, the modem is currently not in use.
Dialing/Primary 3 The modem is currently dialing the primary dial string.
Dialing/Alternate 4 The modem is currently dialing the alternate dial string.
Negotiating/Primary 5 The modem has successfully connected using the primary dial string and is negotiating PPP.
Negotiating/Alternate 6 The modem has successfully connected using the alternate dial string and is negotiating PPP.
Connected/Primary 7 A PPP session has been established using the primary dial string.
Connected/Alternate 8 A PPP session has been established using the alternate dial string.
Failure 9 The modem was unable to establish a PPP connection. Please refer to the primary and alternate Failure Codes for additional information.
Initializing Modem 10 The modem is being initialized.
Dial Backup Status

TABLE 5-1. Status Messages
Status Message SNMP Code Explanation
Modem Hanging Up 12 The modem is in the process of disconnecting.
TABLE 5-2. Failure Codes
0 Normal operation.
100 Unable to initialize modem. Check modem initialization string.
101 PPP negotiation failed. Check CHAP/PAP settings along with user ID and password.
102 Modem dialing failed, no additional information. Enable DBU debug messages and check Event Log for more information.
103 Modem reported “No Carrier”.
104 Modem reported “Error”.
105 Modem reported “No Response” within 45 seconds.
106 Modem reported “No Dial Tone”.
107 Modem reported “Busy”.
108 Modem reported “No Answer”.
IN-tact 1101 Software Configuration Guide 65
Dial Backup Status · Status Message Explanation

Dial Backup Status

The IN-tact 1101 provides event logging in order to help you isolate and troubleshoot specific events that occur on the terminal network. An event is an asynchronous message generated by the system when it encounters a specific situation. The event message contains the severity of the situation and a description.
Keep in mind that not all events captured in the Event Log indicate a problem; many are part of normal operation. Additionally, some events may be transient, while others are persistent. The Event Log provides a window in which to view what is happening and make a determination about any actions you should take.

The screens within the Diagnostics portion of the navigation tree are:
IN-tact 1101 Software Configuration Guide 67

On the navigation tree, click Diagnostics > Event Logging > Setup. The Event Logging Setup screen appears:

In order to use the Event Log, you must set up the IN-tact 1101 to capture specific events. Use the following information to enable event logging. Also, it is important to note that SNMP traps are not filtered by the Event Log settings specified here.
Severity Select the severity level of events to log from the drop-down list.
There are four levels of events and they are listed in order of severity below with Error being the highest. The severity level you select will capture those events, as well as any events that are more critical. For example, if you select the Warning level, both Warning and Error level events will be captured, but not Info or Debug level events.
Error — In most cases, these events will have some impact on operations and transactions may not be processing correctly. Error events usually requires an interaction or attention on your part. Some error events should be exported and forwarded to Hypercom for analysis, as they may indicate a firmware problem.
Info — These events simply provide information; they are not indicative of a problem, but are useful in analyzing what is happening with the device.
Debug — These events are related to the internal operation of the IN-tact 1101 and are not generally useful to anyone but system engineers. These events record buffer allocations and memory addresses to analyze software operation within the device. You may be asked to select this level of logging when working with Hypercom technical support.
Send To Click the Syslog checkbox to send the events to a system log at another location. You must provide an IP address of where to forward the events.
Event Logging Setup

Apply Click when finished setting the Event Log configuration options. The configuration is saved to persistent memory. Any changes are immediately applied; you are not required to reset the device in order for your changes to take place.
On the navigation tree, click Diagnostics > Event Logging > View. The Event Log View screen appears:

The Event Log View window allows you to see any events that have occurred and have been logged. You must first set up event logging in order to capture specific event. See the Event Logging Setup screen for details on what can be captured in the Event Log.
Specified events appear in the scrolling window of the Event Log View screen as they occur. You must use Refresh to update the Event Log and bring the most current events into the window; the Event Log is not automatically updated at any preset interval.
IN-tact 1101 Software Configuration Guide 69
Event Log View

Use Export to create a text file of the events in your browser window. You can then save the file as necessary. Use your browser's Back button to return to IN-tact 1101 Event Log View screen after you save the file. Notepad can be used for viewing the saved file, but you must associate the .dat file extension with Notepad in order to do so.
To configure the Notepad association for .dat files:
The following table lists all of the events that can occur, their severity level, and whether or not an SNMP trap is generated because of the event. SNMP traps are explained in Chapter 8.
Event Log Message Text Severity Level SNMP Trap
Bad log message - - invalid subsystem 0x%x Warning Yes
Bad log message - - invalid ordinal 0x%x for subsystem 0x%x Warning Yes
Assert failed in function %s line %d Error Yes
Improperly formatted SDLC message received from address %02x Warning Yes
Terminal %02x poll lost - - %d Warning Yes
Terminal %02x poll restored Warning Yes
Unable to remove header prior to sending rx data to client Error Yes
Initial offset too large for the buffer Error Yes
Initial length too large for the buffer Error Yes
Unable to format buffer from pool %d Error Yes

Event Log Message Text Severity Level SNMP Trap
Error attempting to add a header to a buffer Error Yes
Retrieved an application frame which is not a buffer msg %d Error Yes
Mailbox %d is full - - message discarded Error Yes
Unable to acquire buffer from pool %d Error Yes
Internal state error for address %02x eDropState=0x%2x Error Yes
Unable to cancel POSIX resource %d Error Yes
Retrieved an invalid event message %x Error Yes
Error reading from HDLC - - %s Error Yes
Invalid length %d bytes read from HDLC Error Yes
Receive buffers exhausted. Frame discarded. Error Yes
Cannot create session to %s:%d - %s Warning Yes
Cannot create SSL session to %s:%d - %s Warning Yes
Persistent session to host %s:%d established Info No
Persistent SSL session to host %s:%d established Info No
Persistent session to host %s:%d closed Warning Yes
Ethernet link lost Error Yes
Ethernet link restored Warning Yes
Received invalid length 0x%04x from %s:%d. Restarting session Error Yes
DNS lookup of name %s failed Warning No
No DNS server configured Error Yes
Invalid administrator password entered from %s Info No
Administrator logged in from %s Warning Yes
Administrator logged out from %s Warning Yes
Administrator password changed by %s Warning Yes
Login session from %s timed out Warning Yes
Maximum failed login attempts Warning Yes
HLAN to IP Events
Improperly formatted message from terminal %02x - - message discarded
Transaction from terminal %02x - - NII %03X routed to default NII Info Yes
Transaction from terminal %02x - - no route to NII %03X - - message discarded
Transaction memory full Error Yes
Open error on subsystem %d Error Yes
IN-tact 1101 Software Configuration Guide 71

Event Log Message Text Severity Level SNMP Trap
Mailbox full for NII %3X Error Yes
Unable to route data from TCP for destination index %02X%02X Error Yes
Invalid data from TCP Error Yes
Using backup host for NII %03X Warning Yes
Restored primary host for NII %03X Info No
Invalid Registry IFace fields @addr:0x%08x Error Yes
Get requested @addr:0x%08x for illegal Item ID=0x%08x Error Yes
Get requested @addr:0x%08x for invalid subrange - Item ID=0x%08x Error Yes
Get requested @addr:0x%08x of Item ID=0x%08x invalid subset index=%d.
Get requested @addr:0x%08x of non-provided Item ID=0x%08x Debug No
Put requested @addr:0x%08x for invalid subrange - Item ID=0x%08x Error Yes
Illegal data interface usage from @addr:0x%08x Error Yes
Unable to initialize modem using init string: XX Warning No
Unable to establish modem connection using dial string: XX Warning No
Unable to establish PPP connection using dial string: XX Warning No
Switched from test mode to normal dial mode Info No
Dial backup subsystem started Info No
Dial backup established using IP address: XX Info Yes
Dial backup disconnecting from IP address: XX Info Yes
SNTP not configured, default date and time are currently in use. Corrective action required.
No response from NTP server or server not found. Using default date and time
No response from NTP server or server not found. Warning No
System time has been synchronized per NTP host XX Info No
Unable to translate NTP host name XX via DNS Warning No
Message sent to channel %02x Debug No
Message received from channel %02x Debug No
Transaction from channel %02x -- NII %03X routed to default NII Info Yes
Transaction from terminal %02x -- no route to NII %03X -- message discarded
Transaction memory full Error Yes

Event Log Message Text Severity Level SNMP Trap
Transacton open error %d Error Yes
Mailbox full for NII %3X Error Yes
Unable to route data from TCP for destination index %02X%02X Error Yes
Invalid data from TCP Error Yes
Using backup host for NII %03X Warning Yes
Restored primary host for NII %03X Info No
IN-tact 1101 Software Configuration Guide 73
Event Log View

Event Log View

This section provides examples of how to configure the IN-tact 1101 to meet various needs. The examples assume a basic knowledge of the IN-tact 1101 purpose and illustrate the versatility of the product. They are not intended to be a replacement for the actual steps required to configure the device. Complete configuration details, including step-by-step instructions, are contained elsewhere in this document.
The screen examples on the following pages illustrate the ease of configuring the IN-tact 1101 via its Web Server application. Two basic scenarios are identified:
IN-tact 1101 Software Configuration Guide 75

System Identification - Managed
This screen allows unique descriptions to be defined for each IN-tact device. This information is essential when multiple IN-tact devices are deployed on a network in order to identify each of the devices. The information entered is returned in a status display when browsing the IN-tact 1101 settings. The Device ID field is alphanumeric and its entry is sent to an SNMP manager when SNMP is utilized for network monitoring purposes. All entries are free-form text and it is up to the user’s discretion to define a numbering and/or identification scheme.
A Device ID must be entered in order to complete configuration requirements. It is also worthwhile to provide a description and location.

Ethernet Port Settings - Minimal
These settings establish the unique identity of the IN-tact 1101’s Ethernet port. DHCP is enabled by default. However, you can disable DHCP and assign a static IP address if necessary.
These values must be synchronized with the IP addressing scheme of the network:
MAC Address Vendor-supplied hardware address and should not be changed
Static IP Address Default address assigned to all IN-tact units. Unless static IP addresses are assigned to each IN-tact 1101 on the network, this can be left as default.
Static Subnet Mask Default value and need not be changed unless static IP addresses are assigned
Static Gateway Address This field is only required if static IP addressing is in use and the IN-tact 1101 is not sharing the same LAN segment as its host destinations. The address of the local gateway router should be entered here if not on the same segment
Static DNS Server Enabled by default. This function is required when static IP addresses are not being used.
Enable DHCP Enabled by default. This function is required when static IP addresses are not being used.
IN-tact 1101 Software Configuration Guide 77

Ethernet Port Settings - Managed
These settings establish the unique identity of the IN-tact 1101’s Ethernet port. These values will need to be synchronized with the IP addressing scheme of the network. In this case, DHCP has been disabled and static IP addressing is being used.

MAC Address Normally not changed.
Static IP Address Reserved IP address
Static Subnet Mask Reserved subnet mask
Static Gateway Address Optionally, this value can be defined if the ISP identifies it as needed. In this configuration, static addressing is used.
Static DNS Server Enter the IP address of the DNS server
Enable DHCP Disabled by clearing the checkbox

Host Processor Setup - Minimal with Single Host
This is an example of a single host processor configuration for a fictional processor, i.e., Acme Processing. There are three screens involved with configuring a host processor (Figs. 1, 2, & 3).

Figure 1. Host Port Settings Screen - Single Host
By restricting the table to a single host processor entry, the end-user terminals are expected to send all POS transactions to a single destination. At lease one host processor must be defined.
NII The use of the NII value allows those terminals initialized with the same NII to be matched for transmission of all traffic to the associated primary IP address
Description A free-form text entry used to identify the processor
Enabled Allows you to temporarily disable, but not delete, a processor
Connection Type Defines whether a Standard or HTTP connection is being used by the processor
Edit Displays the related connection type screen (See Figure 2) and allows you to define addresses
IN-tact 1101 Software Configuration Guide 79

Host Processor Setup - Minimal with Single Host

Figure 2. Standard Host Settings Screen - Single Host
The second host processor setup page is used to define connection mode, IP addressing, and SSL usage:
NII The value is carried over from the first configuration screen
Description The text is carried over from the first configuration screen
Connection Mode Defines the permament or on-demand TCP operation to be in use. This is the normal operation for use with any host LAN server providing TCP/IP connectivity
Enable SSL Click to enable where encryption and authentication are required to be performed by the IN-tact device
Primary Host Address Destination address of the hosting LAN server
Primary Port Assigned socket to which all TCP traffic will be sent
Alternate Host Address Optional entry that defines where to route transactions in the event the primary IP/URL address is unavailable
Alternate TCP Port Socket associated with the alternate IP address.
Visa Protocol Choose whether to use Visa Transparent, Full Transparent, or Spoofed Mode to match host requirements.

Host Processor Setup - Minimal with Single Host

Figure 3. Permanent Mode Settings Screen
NII NII currently being configured
Description The processor currenlty being congifured
Include length field in length calculation
The first two bytes of the POS LAN Header are a length indicator. This option determines whether or not these first two bytes are included as part of the length calculation. This option should be set to match host processor configuration.
IN-tact 1101 Software Configuration Guide 81

Host Processor Setup - Minimal with Multiple Hosts
This is an example of a multiple host processor configuration. Three screens are used to define the host processors in use (Figures 4, 5 & 6).

Figure 4. Host Port Settings Screen - Multiple Hosts
By defining and enabling multiple host processors, the end-user terminals send POS transactions to the destination specified in the NII portion of the TPDU sent from the terminal per each transaction (see Figure 3).
NII Allows those terminals initialized with the same NII to be matched for transmission of all traffic to the associated primary IP address
Description A free-form text entry used to identify the processor
Enabled Allows you to temporarily disable, but not delete, a processor
Connection Type Defines whether a Standard or HTTP connection is being used by the processor
Edit Displays the related connection type screen (see Figure 4) and allows you to define IP addresses.

Host Processor Setup - Minimal with Multiple Hosts

Figure 5. HTTP Host Settings Screen - Multiple Hosts
The second host processor setup page is used to define connection mode, IP addressing, and SSL usage:
NII The value is carried over from the first configuration screen
Description The text is carried over from the first configuration screen
Enable SSL Enable where encryption and authentication are required to be performed by the IN-tact device
Include Two-byte Message Length Header
Use this checkbox to enable Hypercom's proprietary POS LAN header if required for this host connection. This option is disabled by default. The two options below allow further control of the header and should be enabled or disabled according to how the host processor is configured.
Include Length Field in Length Calculation
As mentioned above, the first two bytes of the POS LAN header are a length indicator. This option determines whether or not these first two bytes are included as part of the length calculation. This option should be set to match host processor configuration.
IN-tact 1101 Software Configuration Guide 83

Host Processor Setup - Minimal with Multiple Hosts
Include TPDU The TPDU is the next five bytes of the POS LAN Header and includes information used for routing purposes. This option determines whether or not these five bytes are included as part of the header. This option should be set to match host processor configuration.
Use STX/ETX Wrapper Use this checkbox to enable Start of Text (STX) and End of Text (ETX) wrappers if required by the host. This option is used primarily for hosts that don't run Visa protocol, but want to use async framing.
Discard ACKs Use this checkbox to discard any ACKs sent by the terminals, rather than sending them to the host. This option is used primarily for hosts that don't run Visa protocol, but want to use async framing.
Primary Host Address Destination address of the hosting LAN server
Primary Port Assigned socket to which all TCP traffic will be sent
Alternate Host Address Optional entry that defines where to route transactions in the event the primary IP/URL address is unavailable
Alternate Port Socket associated with the alternate IP address
NOTE: Because this is an HTTP connection type, Connection Mode is not used for this processor.

Host Processor Setup - Minimal with Multiple Hosts
Figure 6. Permanent Mode Settings Screen
NII NII currently being configured
Description The processor currenlty being congifured
Include length field in length calculation
The first two bytes of the POS LAN Header are a length indicator. This option determines whether or not these first two bytes are included as part of the length calculation. This option should be set to match host processor configuration.
IN-tact 1101 Software Configuration Guide 85

Transaction Routing - Minimal
Each IN-tact 1101 should be provisioned with a standard set of routing rules.
The rules determine how transactions will be routed between the terminal and host:

Merchant Terminal Setup - Minimal
The site survey checklist provides the information needed to verify the number and location of the terminals in use at the merchant location.
IN-tact 1101 Software Configuration Guide 87

SNMP Setup - Managed
The managed approach to provisioning allows the use of Simplified Network Management Protocol (SNMP) to be enabled.

NOTE: If the IN-tact is behind a NAT firewall, ports 80 and 443 will require port forwarding in order to
access the web interface of the IN-tact 1101. To use SNMP remote management, additional setup of the router may be required. SNMP port addresses 161 and 162 will need to be accessible. You may also have to configure Virtual Server Settings within the router to set up both ports 80 and 443 as TCP for the web interface, and ports 161 and 162 as UDP for SNMP access. Refer to the router documentation for more information on performing these setup items.

SNMP Setup - Managed
An important part of configuring the IN-tact 1101 is determining any NII codes in use. The NII code is used to route transactions from the terminal to the correct host processor. In the IN-tact 1101, this configuration is done on the IN-tact Setup > Application Setup > Host Port Settings screen.

In some cases, all terminals may route to a single processor. In other cases (like this example), multiple processors may be used. Knowing the correct NII codes to use becomes even more critical in these cases. For customers who do not use NII routing, this procedure can be ignored.
By defining and enabling multiple host processors, the end-user terminals send POS transactions to the destination specified in the NII portion of the TPDU sent from the terminal per each transaction. The use of the NII value allows those terminals initialized with the same NII to be matched for transmission of all traffic to the associated primary IP address. Other entries on the screen define the IP address or URL used for routing, whether or not an SSL configuration is needed (encryption and authentication are required to be performed by the IN-tact device), and whether the connection is established on a permanent or on-demand basis.
The NII value can be extracted from the terminal by doing a hex dump. The hex dump can be forwarded to the ISO or support center that is configuring the IN-tact 1101.
IN-tact 1101 Software Configuration Guide 89

SNMP Setup - Managed
To perform a hex dump on a terminal:
ICE Series Terminals T Series Terminals
The terminal will now start printing a hex dump.
To determine the NIIs in use from the hex dump:
In the data segment, there are four phone number fields. There are easily identified because each one is followed by a series of “FF” bytes. These generally occupy the first four rows.
The next two bytes (four characters) identify the NII. In most cases, the NII bytes appear on the fifth row and start with the seventh character. See the following example:


The IN-tact 1101 SNMP agent is capable of sending out traps (asynchronous notifications) to the configured SNMP manager IP addresses. SNMP manager addressing is configured on the System Setup > Management screen. See page 24 for details on configuring this option. Each trap includes the following fields:
enterprise Identifies the subsystem that generated the trap. The value is taken from sysObjectID in the system group (MIB-II).
agent-addr The IP address of the object generating the trap.
specific-trap A code that more specifically indicates the nature of the trap.
IN-tact 1101 Software Configuration Guide 91
Field Description

time-stamp The time between the last initialization of the network entity that issued the trap and the generation of the trap.
variable_bindings Additional implementation-specific information relating to the trap.
SNMP requests act on a variable-per-variable basis. However, in most cases, you will want to modify multiple variable first, then after all the changes are done, submit the whole configuration and apply all of the changes at the same time. To accomplish this, the following provisions were made:
To begin a configuration change, you can modify a variable in the System Configuration group. The SNMP agent automatically changes the configEditionControl value to “editing”. A timer starts to give you a period of time to use the SNMP interface for configuration changes. This expires after 30 minutes of no activity. A detailed explanation of this timeout feature is described below.
Another possibility is to manually set the configEditionControl value to “editing” before changing any other variable. The resulting behavior is the same.
Once an edition has started, you can modify as many variables as needed. When all of the changes have been made, set the configEditionControl value to “applyCfgChanges”. This tells the SNMP agent to validate the cached configuration and, if successful, commit it to flash.
Before committing a configuration to flash, it is validated. If correct, it is saved and the device resets. If there is a problem with the validation, the MIB variable “lastSNMPError” contains the error code and the MIB variable “lastSNMPErrorString” contains the corresponding error message. You can obtain these values using SNMP Get requests. The SNMP agent keeps the cached configuration in memory, so you can review and fix the problem, then try to commit again.
SNMP Usage · Field Description

Once the configEditionControl variable is set to “editing”, it cannot be set to the same value. A second request to do so will fail. This mechanism helps avoid collisions by different managers when changing a configuration. You can also get the current value for this variable to verify that no one else is using the SNMP interface for configuration changes.
The configEditionControl variable can also be set to “discardCfgChanges” to make the SNMP agent disregard any changes cached so far.
If the period of time specified by the timer elapses without any new SNMP Set request received by the SNMP agent, all of the changes cached so far are disregarded and configEditionControl is changed to “noAction” automatically.
NOTE: Setting time on the IN-tact 1101 via SNMP resets the device. Any other “sets” you may have
made and not committed via “applyCfgChanges” will be lost. Therefore, always set time as a separate operation if configuring the device with an SNMP manager. You can then make any other configuration changes as necessary and commit them when ready.
The following traps can be sent to the SNMP manager to alert you to possible problems. The “System Error” trap can indicate many different conditions; the specific error is denoted by a four- digit code within the text of the trap message. These messages are used by Hypercom Engineering to diagnose specific problems within the IN-tact 1101. The following System Error Code table correlates the error code to problem description.
Trap File Name Description
TCP Connection Failed (1) (trapTCPConnFailed) Issued due to a TCP connection failure while attempting to make a connection
SSL Failure (2) (trapSSLFailure) Issued when an SSL failure occurs. Includes certificate authentication failure or any other denial of service during negotiation
Permanent connection lost (3) (trapPermanentConnLost) Issued when an unexpected disconnect from a host occurs while in permanent mode
Message routed to default NII (4) (trapMsgRoutedToDefaultNII) Issued when a message is sent to the default NII while in embedded routing mode
Message discarded (5) (trapMsgDiscarded) Issued when an undeliverable, non- routable message is discarded based on discard option set or loss of terminal with transaction in flight
Invalid Host Message (6) (trapInvalidHostMessage) Issued when an improperly formatted message is received from a host
IN-tact 1101 Software Configuration Guide 93
Trap Definitions

Trap File Name Description
Switched to Alternate Host (7) (trapSwitchedToAlternate) Issued when switching to alternate IP address due to loss of keep alive or loss of TCP session when in permanent TCP mode
Invalid Terminal Message (8) (trapInvalidTerminalMessage) Issued when an improperly formatted message is received from a terminal
Terminal Poll Lost (9) (trapTerminalPollLost) Issued when a transition from receiving responses to SDLC poll to no response is detected
Terminal Poll Restored (10) (trapTerminalPollRestored) Issued when a transition from no poll response to receiving a poll response is detected
Admin Logged In (11) (trapAdminLoggedIn) Issued whenever anyone logs in to the IN-tact 1101 using the “admin” User ID and password
Admin Logged Out (12) (trapAdminLoggedOut) Issued whenever “admin” logs out of the IN-tact 1101
Admin Password Changed (13) (trapAdminPasswordChanged) Issued whenever the password for the User ID “admin” is changed
Session Timed Out (14) (trapSessionTimedOut) Issued when the five-minute timer expires during a session. The session is closed and the user is logged out
Maximum Failed Login Attempts (15)
(trapMaxFiledLoginAttempts) Issued whenever the three consecutive failed attempts were made to log in to the IN-tact 1101
System Error (99) (trapSystemError) Issued when the device detects an unexpected condition. A four-digit code within the trap identifies the unexpected condition. Refer to the Error Code table.
The following variables are provided in order to use SNMP to configure SNTP:
SntpStatus Read-write variable with two choices: enabled and disabled.
TimeZone Read-write variable. Refer to the Time Zone Table for SNMP fto determine the numerical identifier of the time zone you wish to set.
PrimaryNTPServerFromDHCP Read-only variable. Displays the primary NTP server assigned by DHCP, if any.
AlternateNTPServerFromDHCP Read-only variable. Displays the alternate NTP server assigned by DHCP, if any.
NtpServersSearchOrder Read-write variable with two choices: dhcpFirst and staticFirst.
StaticPrimaryNTPServer Read-write variable. IP address or name of static primary NTP server.
Trap Definitions · Variable Description

StaticAlternateNTPServer Read-write variable. IP address or name of static alternate NTP server.
SntpSynchronizationInterval Read-write variable. Integer with valid values from 1 through 24.
For manual time synchronization, the SynchronizeSNTP variable can be used. It is a read-write variable with noAction and synchronize as its values.
Error Code Error Description SNMP Trap
00-00 Bad log message -- invalid subsystem 0x%x Yes
00-01 Bad log message -- invalid ordinal 0x%x for subsystem 0x%x Yes
01-00 Assert failed in function %s line %d Yes
01-01 Configuration saved -- restarting Yes
01-02 System error -- restarting Yes
01-03 Reverting to default configuration Yes
01-04 Reverting to factory default Yes
02-05 Unable to remove header prior to sending rx data to client Yes
02-06 Initial offset too large for the buffer Yes
02-07 Initial length too large for the buffer Yes
02-08 Unable to format buffer from pool %d Yes
02-09 Error attempting to add a header to a buffer Yes
02-10 Retrieved an application frame which is not a buffer Msg %d Yes
02-11 Mailbox %d is full -- message discarded Yes
02-12 Unable to acquire buffer from pool %d Yes
02-13 Internal state error for address %02x eDropState=0x%2x Yes
02-14 Unable to cancel POSIX resource %d Yes
02-15 Retrieved an invalid event message %x Yes
02-16 Error reading from HDLC -- %s Yes
02-17 Invalid length %d bytes read from HDLC Yes
03-00 Receive buffers exhausted. Frame discarded. Yes
IN-tact 1101 Software Configuration Guide 95

Error Code Error Description SNMP Trap
04-08 Ethernet link lost - If the dial backup link is not established when the Ethernet link is lost, this message appears only in the Event Log, but not in the syslog or SNMP trap destination.
04-09 Ethernet link restored Yes
04-11 Received invalid length 0x%04X from %s:%d. Restarting session Yes
05-06 Configuration file imported from %s Yes
HLAN to IP Events
06-00 Improperly formatted message from terminal %02x -- message discarded
06-03 Transaction memory full Yes
06-04 Open error on subsystem %d Yes
06-05 Mailbox full for NII %3X Yes
06-06 Unable to route data from TCP for destination index %02X%02X Yes
08-01 Invalid Registry IFace fields @addr:0x%08x Yes
08-02 Get requested @addr:0x08x%08x for illegal Item ID=0x%08x Yes
08-03 Get requested @addr:0x%08x for invalid subrange - Item ID=0x%08x Yes
08-06 Put requested @addr:0x%08x for invalid subrange - Item ID=0x%08x Yes
08-07 Illegal data interface usage from @addr:0x%08x Yes

Time Zone Table for SNMP
Time Zone Displayed Name Numerical Identifier
(GMT - 12:00) Eniwetok, Kwajalein Pacific/Kwajalein 1
(GMT - 11:00) Midway Island, Samoa Pacific/Midway 2
(GMT - 10:00) Hawaii US/Hawaii 3
(GMT - 09:00) Alaska US/Alaska 4
(GMT - 08:00) Pacific Time (US & Canada); Tijuana US/Pacific 5
(GMT - 07:00) Arizona US/Arizona 6
(GMT - 07:00) Chihuahua, La Paz, Mazatlan America/Chihuahua 7
(GMT - 07:00) Mountain Time (US & Canada) US/Mountain 8
(GMT - 06:00) Central Time (US & Canada) US/Central 9
(GMT - 06:00) Mexico City, Tegucigalpa America/Mexico_City 10
(GMT - 06:00) Saskatchewan Canada/Saskatchewan 11
(GMT - 05:00) Bogota, Lima, Quito America/Bogota 12
(GMT - 05:00) Eastern Time (US & Canada) US/Eastern 13
(GMT - 05:00) Indiana (East) US/East-Indiana 14
(GMT - 04:00) Atlantic Time (Canada) Canada/Atlantic 15
(GMT - 04:00) Caracas, La Paz America/Caracas 16
(GMT - 04:00) Santiago America/Santiago 17
(GMT - 03:30) Newfoundland Canada/Newfoundland 18
(GMT - 03:00) Brasilia America/Sao_Paulo 19
(GMT - 03:00) Buenos Aires, Georgetown America/Buenos_Aires 20
(GMT - 02:00) Mid-Atlantic America/Noronha 21
(GMT - 01:00) Azores Atlantic/Azores 22
(GMT - 01:00) Cape Verde Is. Atlantic/Cape_Verde 23
(GMT) Casablanca, Monrovia Africa/Casablanca 24
(GMT + 01:00) Amsterdam, Berlin, Bern, Rome, Stockholm, Vienna
(GMT + 01:00) Belgrade, Bratislava, Budapest, Ljubljana, Prague
(GMT + 01:00) Brussels, Copenhagen, Madrid, Paris
(GMT + 01:00) Sarajevo, Skopje, Warsaw, Zagreb Europe/Sarajevo 29
(GMT + 01:00) West Central Africa Africa/Bangui 30
(GMT + 02:00) Athens, Istanbul, Minsk Europe/Athens 31
(GMT + 02:00) Bucharest Europe/Bucharest 32
(GMT + 02:00) Cairo Africa/Cairo 33
(GMT + 02:00) Harare, Pretoria Africa/Harare 34
(GMT + 02:00) Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius
IN-tact 1101 Software Configuration Guide 97

The MIB used by the SNMP agent within the IN-tact 1101 can be downloaded from the Hypercom website at http://www.hypercom.com It is in the Products/IP Gateway device section of the site.
IN-tact 1101 Software Configuration Guide 99
IN-tact 1101 MIB


Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| 100 | DNS error | p.68 | |
| 110 | Socket creation error | p.68 | |
| 120 | General connection error | p.68 | |
| 121 | Connection refused | p.68 | |
| 122 | Connection timed out | p.68 | |
| 130 | General SSL error | p.68 | |
| 131 | SSL certificate validation failed | p.68 | |
| 132 | SSL timeout | p.68 | |
| 00-00 | Bad log message -- invalid subsystem 0x%x | p.101 | |
| 00-01 | Bad log message -- invalid ordinal 0x%x for subsystem 0x%x | p.101 | |
| 01-00 | Assert failed in function %s line %d | p.101 | |
| 01-01 | Configuration saved -- restarting | p.101 | |
| 01-02 | System error -- restarting | p.101 | |
| 01-03 | Reverting to default configuration | p.101 | |
| 01-04 | Reverting to factory default | p.101 | |
| 01-06 | Start: LAN MAC %s IP %s | p.101 | |
| 02-05 | Unable to remove header prior to sending rx data to client | p.101 | |
| 02-06 | Initial offset too large for the buffer | p.101 | |
| 02-07 | Initial length too large for the buffer | p.101 | |
| 02-08 | Unable to format buffer from pool %d | p.101 | |
| 02-09 | Error attempting to add a header to a buffer | p.101 | |
| 02-10 | Retrieved an application frame which is not a buffer Msg %d | p.101 | |
| 02-11 | Mailbox %d is full -- message discarded | p.101 | |
| 02-12 | Unable to acquire buffer from pool %d | p.101 | |
| 02-13 | Internal state error for address %02x eDropState=0x%2x | p.101 | |
| 02-14 | Unable to cancel POSIX resource %d | p.101 | |
| 02-15 | Retrieved an invalid event message %x | p.101 | |
| 02-16 | Error reading from HDLC -- %s | p.101 | |
| 02-17 | Invalid length %d bytes read from HDLC | p.101 | |
| 03-00 | Receive buffers exhausted. Frame discarded. | p.101 | |
| 04-08 | Ethernet link lost - If the dial backup link is not established when the Ethernet link is lost, this message appears only in the Event Log, but not in the syslog or SNMP trap destination. | p.102 | |
| 04-09 | Ethernet link restored | p.102 | |
| 04-11 | Received invalid length 0x%04X from %s:%d. Restarting session | p.102 | |
| 05-06 | Configuration file imported from %s | p.102 | |
| 06-00 | Improperly formatted message from terminal %02x -- message discarded | p.102 | |
| 06-03 | Transaction memory full | p.102 | |
| 06-04 | Open error on subsystem %d | p.102 | |
| 06-05 | Mailbox full for NII %3X | p.102 | |
| 06-06 | Unable to route data from TCP for destination index %02X%02X | p.102 | |
| 08-01 | Invalid Registry IFace fields @addr:0x%08x | p.102 | |
| 08-02 | Get requested @addr:0x08x%08x for illegal Item ID=0x%08x | p.102 | |
| 08-03 | Get requested @addr:0x%08x for invalid subrange - Item ID=0x%08x | p.102 | |
| 08-06 | Put requested @addr:0x%08x for invalid subrange - Item ID=0x%08x | p.102 | |
| 08-07 | Illegal data interface usage from @addr:0x%08x | p.102 |