Instruction/ maintenance manual of the product SCSS-SL hussman
Go to page of 24
/Chino SCSS / SCSS-SL SER VICE BAKER Y REV . 0108 Installation & Operation Manual SCSS / SCSS-SL SER VICE BAKER Y P/N IGSSB-SCSS / SCSS-SL-0108 INST ALLA TION & OPERA TION GUIDE.
IGSSB-SCSS / SCSS-SL-0108 2 /Chino A publication of Hussmann ® Chino 13770 Ramona A v enue • Chino , California 91710 (909) 628-8942 F AX (909) 590-4910 (800) 395-9229 K eep this booklet with the case at all times for future r eference.
Rev. 0108 3 report and r equir ed claim forms. SHOR T AGES Check y our shipment for an y possible shortages of mate- rial. If a shor tage should exist and is f ound to be the re- sponsibility of Hussmann Chino , notify Hussmann Chino . I f such a shortage involv es the car rier , notify the carr ier imme- diately , and r equest an inspection.
IGSSB-SCSS / SCSS-SL-0108 4 Cut & Plan Views 40 3 / 4 " (S/C Height) SCSS Summit Cake Service Bakery Case (Remote & Self Contained) Scale = 1/2" 12 " 9 3 / 4 " 25 1 / 2 &qu.
Rev. 0108 5 LOCA TION The refrigerated mer chandisers hav e been designed f or use only in air conditioned stor es wher e temperatur e and humidity are maintained at or belo w 75 ° F and 55% r ela- tive humidity . DO NO T allow air conditioning, electric fans, ov ens, open doors or windows (etc.
IGSSB-SCSS / SCSS-SL-0108 6 Plumbing WASTE OUTLET AND P-TRAP The waste outlet is located off the center of the case on one side allowing drip piping to be run lengthwise under the fixture. A 3/4" P-trap and thr eaded adapter ar e supplied with each fixture.
Rev. 0108 7 Refrigeration REFRIGERANT TYPE The standard r efrigerant will be R-22 unless otherwise specified on the customer order . Check the serial plate on the case for information.
IGSSB-SCSS / SCSS-SL-0108 8 T-STAT LOCATION T -Stats are located within the electrical race wa y . Condensing Unit Installation Requirements For pr oper operation of the Condensing Unit pr ovide an opening with adequate exhause and intak e as follo ws: Up to 1 1/2 hp: minimum of 2 v ents totalling 150 sq.
Rev. 0108 9 Electrical WIRING COLOR CODE GREEN GROUND PURPLE ANTI-SWEA T ORANGE LIGHTS YELLOW RECEPT ACLE RED / BLACK T -STA T /SOLENOID 230V BLACK / WHITE T -S TAT / SOLENOID 115V B RO W N FAN MO TORS CASE MUST BE GROUNDED NOTE: Refer to label affixed to case to determine the actual configuration as checked in the “TYPE INSTALLED” boxes.
IGSSB-SCSS / SCSS-SL-0108 10 EKC 201 CONTROLLERS EKC 201 Fig. 1 t room = 0 → +55 ° C t system = – 60 → +50 ° C 12 V a.c./230 V a.c. 2.5 V A IP 54 Identification (See figs 1 and 2). 1. Light emitting diode = refrigeration = defrost = fan running 2.
Rev. 0108 11 Controller application setting parameters P ara- Controller Min. Max. F actory Actual Setting and read-off parameters meter application no. value value setting setting codes 12 34 1 ) The compressor relay closes when the room temperature exceeds the setting value and diff erential.
IGSSB-SCSS / SCSS-SL-0108 12 User Information STOCKING In order to maximize pr oduct life , maintain a constant and pr oper pr oduct temperature fr om the time the product is receiv ed thr ough storage, preparation and displa y .
Rev. 0108 13 2. Scrub thor oughly , cleaning all surfaces, with soap and hot water . 3. Rinse with hot water , but do not flood. 4. Apply the sanitizing solution according to Hussmann’ s directions. 5. Rinse thoroughl y . 6. Dr y completely bef or e resuming operation.
IGSSB-SCSS / SCSS-SL-0108 14 Maintenance ELECTRICAL PRECAUTIONS BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component This includes (but not limited to) Fans, Heaters, Thermostats, and Lights.
Rev. 0108 15 Electrical Schematics Date: Project Title: Drawing N o.: Drawn By : Assembly: Drawin g Title: Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue Chino , CA.
IGSSB-SCSS / SCSS-SL-0108 16 Date: Project Title: Drawing N o.: Drawn By : Ass embly : Dra wing Title : Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue Chino , CA. 91710 (909)- 590-491 0 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Loc ation: Boris Kasr el BJK Sheet of H:Wir ingSc hematicsIn-Wor k.
Rev. 0108 17 Date: Project Title: Drawing N o.: Drawn By : Ass embly : Dra wing Title : Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue Chino , CA. 91710 (909)- 590-491 0 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Loc ation: Boris Kasr el BJK Sheet of H:Wir ingSc hematicsIn-Wor k.
IGSSB-SCSS / SCSS-SL-0108 18 Date: Project Title: Drawing N o.: Drawn By : Ass embly : Dra wing Title : Date: Hussmann Corp oratio n, Int'l. 137 70 Ramona Avenue Chino , CA. 91710 (909)- 590-491 0 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Loc ation: Boris Kasr el BJK Sheet of H:Wir ingSc hematicsIn-Wor k.
Rev. 0108 19 APPENDIX A. – TEMPERATURE GUIDELINES REFRIGERATED The refrigerators should be operated according to Hussmann ’ s published engineering specifications for en- tering air temperatures for specific equipment applica- tions.
IGSSB-SCSS / SCSS-SL-0108 20 this evaluation, product temperature above the FDA Food Code 1993 temperature for potentially hazardous food will be the first indication that an evaluation should be performed. It is expected that all refrigerators will keep food at the FDA Food Code 1993 temperature for potentially hazardous food.
Rev. 0108 21 ments with detergent and water will keep the equip- ment presentable and prevent grime buildup. 1.2 Load levels as defined by Hussmann must be ob- served. 1.3 The best preservation is achieved by following these rules: a) Buy quality products.
IGSSB-SCSS / SCSS-SL-0108 22.
Rev. 0108 23 Limited W arranty This warranty is made to the original user at the original installation site and is not transf erable . Hussmann mer chandisers are war ranted to be fr ee fr om defect i.
IGSSB-SCSS / SCSS-SL-0108 24 The MODEL NAME and SERIAL NUMBER is required in or der to pr ovide y ou with the corr ect parts and information for your particular unit. They can be f ound on a small metal plate on the unit. Please note them below for futur e r eference.
An important point after buying a device hussman SCSS-SL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought hussman SCSS-SL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data hussman SCSS-SL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, hussman SCSS-SL you will learn all the available features of the product, as well as information on its operation. The information that you get hussman SCSS-SL will certainly help you make a decision on the purchase.
If you already are a holder of hussman SCSS-SL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime hussman SCSS-SL.
However, one of the most important roles played by the user manual is to help in solving problems with hussman SCSS-SL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device hussman SCSS-SL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center