HP S to r e V irtual S tor age Multi- Site C onf i gur ati o n Guide Abstract This gui de contains detailed instru ctions f or designing and implementing the Multi- Site SAN f eatures o f the LeftHand OS . The Multi-Site S AN featur es enable y ou to sy nchr onousl y and automaticall y mirror dat a between geogr aphic sites .
© Cop yr ight 2009 , 20 1 3 He wlett-P ack ard Dev elopment Co mpany , L.P . Conf idential com puter softwar e. V alid license f rom HP r equired f or posse ssion , use or copy ing.
C onte nts 1 Designing a Multi- Site S AN.........................................................................5 Designing the ne t w ork f or the Multi-Site S AN...............................................................................5 Best pr acti ces fo r implementing the Multi-Sit e SAN ne t w ork.
T o add ca pacity............................................................................................................28 R emov ing stor age s ys tems fr om a Multi-Sit e clus ter.................................................................
1 Desi gning a Multi- Site S AN The HP S tor e V irtual Multi-Site S AN featur es ena ble you to s y nchr onou sly mirr or data be t w een sites auto matically . Y ou cr eate a Multi- Site S AN by conf igur ing equal number s of stor age s ys tems into sites in the s oftwar e.
• Lo w round-trip latenc y —In orde r to not impact disk I/O t o the applicatio n server , the round-tr ip latenc y bet w een the sites mu st be no mor e than 2 ms. • Redundant links —Ha ve multiple ph y sical connecti ons (media) betw een the sites f or redundanc y .
Sample r ecomme nded networ k conf igur ati ons for Multi- Site S ANs This s ection pr o v ides illus trati ons of common netw ork conf igur ations f or the topologi es desc ribed in T able 1 (page 6) .
Figur e 3 T riangular network with Failo ver Manager 1 . Dual r edundant GigE links Figur e 4 Hub and spoke networ k core with redundant links out t o eac h site 1 .
Figur e 5 Combination full-mesh core with tr iangular links to all sites 1 . F ull mesh core ne t w ork Using m ultiple subnets IMPORT ANT: Be st pr actice is to u se a single subnet in mo st cases . Y ou can use multiple su bnets with a Multi- Site S AN.
Figur e 6 M ulti- Site SAN mapping to subnets, VI P s, and application ser vers 1 . Dual r edundant GigE links Co nnecting vo lumes to multiple subnets in a Multi- Site S AN using the Mi cr os oft iS .
Figur e 7 Entering VIP s in a Multi-Site S AN configuration 2. On the T argets t ab, s elect the v olume to log on to . 3. C lick L og On . 4. Selec t the Enable multi-path check bo x if using MP IO . Figur e 8 Logging on to v olume 5 . [Optional] If y ou w ant this volume t o be av ailable after r ebooting, s elect the Automaticall y restor e.
Figur e 9 T arget portal value remains Def ault 8. After s etting the values , cli ck OK to c lose the Ad vanced Se ttings dialog . 9 . Clic k OK again to finish logging on . 1 0. If y ou want t o set the MPIO load balanc ing poli cy , see the HP St ore Virtual Stor age DSM f or MPIO Deplo y ment Guide .
In addition t o setting up the Multi-Site c lust ers fo r data repli cation , it is important to se t up the S AN managers f or quor um corr ectl y to ensur e that in the ev ent of a f ailure the s y stem can be pr oper ly r ecov er ed. Maint aining quorum can be e ither an aut omated pr ocess or manuall y r ecov er ed by an Adminis trato r .
Figur e 1 1 T wo ph ysical sites, logical thir d site: c luster spans two sites, Failo ver Manager in logical third site 1 . V olumes ar e conf igured w ith Netwo rk RAID- 1 0 Figur e 1 2 Thr ee phy sical sites: c luster spans three sites 1 .
Figur e 1 3 T wo ph ysical sites: cluster spans t wo sites, one site is the primary site 1 . V olumes ar e conf igured w ith Netwo rk RAID- 1 0 Bes t pr acti ces f or conf igur ing qu orum and manager.
T able 3 Common Multi-Site S AN configurations with r ecommended manag ers Number of managers and number Needed to maintain quorum Manager configuration Multi-Site S AN configuration • Manager count.
T able 4 Data protection lev els and the suppor ted number of sites Number of sites supported Data protection lev el T wo Netwo rk RAID- 1 0 Thr ee NO TE: T w o sites ar e supported, bu t not consider ed a best pr actice conf igur ation .
T able 5 Failur e conditions and resolutions Resolution steps Failur e condition None . The pr imar y site w ill continue to oper ate . Secondary site off line None . The pr imar y site w ill continue to oper ate . Networ k link between sites f ails Primary site o ffline 1 .
T able 6 Alternati ve Multi-Site S AN configurations (continued) Details Description Alternate configur ation be Multi-Site if it is to co ntain stor age sy stems fr om differ ent subne ts.
2 Imple menting a Multi- Site S AN After y ou ha ve de signed the Multi-Site S AN co nfigur atio n, y ou ar e read y to implemen t it. Bef or e y ou begin Install Multi- Site S AN featur e k ey s on the st orage s y stems y ou ar e going to u se . R egister y our stor age s ys tems.
Figur e 1 4 Using the manag ement group w izar d to create a Multi-Site SAN NO TE: Y ou must ha ve at leas t one stor age s ys tem for eac h site in the A vaila ble S yst ems pool bef or e starting.
Cr eating sites When c r eating a new site , y ou fir st cr eate the sit e and then assign s tor age sy stems t o that site: 1 . Clic k N e w to open the New Sit e windo w . 2. Ent er a name for the site and an opti onal desc ripti on. 3. [Opti onal] Mak e the site pr imar y , if appr opri ate .
Figur e 1 6 Vie wing the Sites Details tab windo w C on ve r ting an e x isting S AN to a Multi-Site S AN P lan the conv ersi on accor ding to the cr iter ia des cr ibed in “Prepar ing to con vert an e x isting S AN to a Multi-Sit e SAN” (page 20) .
1 0. Assign o ne or mor e VIP s as planned for y our site la yo ut, and the n clic k Next . The Cr eate V olume w indow opens w ith the Skip V olume Creati on box c heck ed . If yo u want to c reate a ne w v olume for y our Multi-Sit e clus ter , clear the bo x and fill in the v olume info rmation .
Best pr acti ce Install the F ailo ve r Manager on a serve r in a separat e phy sical locati on fr om the S AN sites , and then add it as a separ ate site in the manage ment gr oup . Doing so w ill pr ev ent los s of quor um in a site failur e , r egardle ss of w hich single site f ails.
V ie w ing sites in the CM C T o v ie w sites in the CM C, select the Sites node in the nav igati on w indow . The Site s node is displa yed in e very management gr oup . T ypi cally , how ev er , the Sites Details tab sh ow s the stor age s ys tems as unas signed.
• Sites • Sites (Gr ouped) Designating a pr imary site Use the Pr imary designati on when y ou ar e using the Multi- Site clu ster to maint ain a primary site and a second sit e as a back up site . Designat e the site as Pr imar y whe n you c r eate the site , or y ou can edit an e xis ting site to mak e it primary .
1 . Select the Sites node in the na vi gation w indo w . 2. Se lect the site y ou wan t to delete in the Details ta b, r ight-cli ck , and then selec t Delete Site . NO TE: If onl y one site will be le ft in the clust er , the war ning sho wn in “Deleting a site that contains a s torage s y stem cau ses this w arning ” (page 28) is display ed .
R emo v ing sto r age s ys tems f r om a Multi-Sit e clu ster R emov ing stor age s ys tems fr om a Multi-Sit e clus ter affec ts the capacity of the c luste r and the Multi-Site co nfigur ati on. • Ensur e that the capac it y r emaining after y ou r emov e the stor age s ys tem(s) is suffi c ient f or the data on the v olumes .
3 Suppo r t and other r es our ce s C ontac ting HP F or w orld wi de techni cal support info rmation , see the HP suppo r t w ebsite: http://www .hp .
initiate a f ast and acc ur ate re soluti on, bas ed on yo ur produc t’s serv ice le vel . Notif ications ma y be sent t o your a uthor iz ed HP Channel P ar tner f or on -site se r v ice , if confi gured and a vaila ble in your country .
4 Doc umen tati on f eedbac k HP is committed to pr o vi ding documen tation that meets y our needs . T o help u s impr ov e the doc umentatio n, send an y er ro rs, sugge stions , or comments to Doc umentati on F eedback ( docsfeedback@hp.
Glos sary The f ollo w ing glossary pr ov ides de finiti ons of ter ms used in the L eftHand OS so ft war e and the HP Sto re Virtual St orage . acting primary volume The r emote v olume , when it as sumes the r ole of the primary v olume in a failo ver sce nario .
DSM De vi ce Spec ifi c Module. DSM f or MPIO The HP S tor e V ir tual DSM f or Mic r osoft MP IO vendor -spec ifi c DSM that inte rfaces w ith the Mic ro soft MPIO f rame w ork. failback After f ailov er , the proce ss by w hic h you r est ore the pr imary volume and turn the ac ting primary back in to a remo te volume .
MIB Management infor mation bas e. A data base of managed obj ects accessed b y netwo rk management pr otocols. A n SNMP MIB is a set of par ameter s that an SNMP management s tation can query or set in the S NMP agent of a netw ork de vi ce (for e xam ple, a r outer ).
RAI D rebuild r ate The r ate at w hich the RAID conf igurati on r ebuilds if a disk is replaced . RAI D status C ondition o f R AID on the stor age s yst em: • Normal - RAID is s ync hroni z ed and running . No acti on is req uired . • Rebuild - A ne w disk has been ins erted in a dri ve ba y and RAID is curr entl y rebuilding .
site A user -desi gnated location in w hic h stor age sy stems ar e installed . Multi-Site S AN conf igur ations hav e multiple sites w ith sto rage s ys tems in each site , and eac h site has its ow n subnet . A site can be a logical conf igur ation , such as a su bnet within the same data cent er , depar tment , or applicati on.
volume si ze T he siz e of the virtual de vi ce communicated to the ope rating s ys tem and the applicati ons. VSS Pr ov ider HP Sto re Virtual VS S Pro v ider is the har dw are pr ov ider that su pports the V olume Shado w Cop y Serv ice on the HP Stor e Virtual Stor age .
Inde x S y mbols 2 -site conf igur ations pr imar y site designati on in, 1 7 A adding additional ca pacity to e xisting sit es, 2 8 site , 2 7 stor age s yst ems to Multi-Site c luster , 28 alter nat.
fo r sites, 2 6 MPIO and m ultiple subnets, 1 2 Multi-Site c luste r cr eating , 2 1 r emov ing stor age s yst ems fr om, 2 9 w iz ar d, 2 3 Multi-Site S AN alter nativ e confi gurati ons, 1 8 common .
An important point after buying a device HP (Hewlett-Packard) AX696-96243 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought HP (Hewlett-Packard) AX696-96243 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data HP (Hewlett-Packard) AX696-96243 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, HP (Hewlett-Packard) AX696-96243 you will learn all the available features of the product, as well as information on its operation. The information that you get HP (Hewlett-Packard) AX696-96243 will certainly help you make a decision on the purchase.
If you already are a holder of HP (Hewlett-Packard) AX696-96243, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime HP (Hewlett-Packard) AX696-96243.
However, one of the most important roles played by the user manual is to help in solving problems with HP (Hewlett-Packard) AX696-96243. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device HP (Hewlett-Packard) AX696-96243 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center