HOBART HGF, HGD AND HGC SERIES GAS FRYERS
WITH OR WITHOUT FILTER-IN-A-DRAWER
MODELS
HGF35 ML-126994
HGF35F ML-135536
HGF45 ML-126995
HGF45F ML-135537
HGF65 ML-126996
HGF65F ML-135538
HGF85 ML-126997
HGF85F ML-135539
HGFD35 ML-126416
HGD35F ML-126953
HGFD45 ML-126417
HGD45F ML-126956
HGFD65 ML-126418
HGD65F ML-126959
HGFD85 ML-126419
HGD85F ML-126962
HGFC35 ML-126420
HGC35F ML-126954
HGFC45 ML-126421
HGC45F ML-126957
HGFC65 ML-126422
HGC65F ML-126960
HGFC85 ML-126423
HGC85F ML-126963
701 S. RIDGE AVENUE TROY, OHIO 45374-0001
FORM 35643 Rev. A (Apr. 2005)
937 332-3000

THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER.
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE.

Installation, Operation and Care of MODELS HGF, HGD and HGC SERIES GAS FRYERS
GENERAL
Hobart HGF, HGD and HGC Series Gas Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance of your fryer will result in many years of satisfactory performance.
It is suggested that you thoroughly read this entire manual and carefully follow all of the instructions provided.
The Mobile Filter, used for filter-ready fryers, is covered in a separate Instruction Manual. Fryers equipped with Filter-In-A-Drawer are covered in a separate Instruction Manual. Follow the instructions in the appropriate manual for filtering, draining and dumping shortening.
Hobart HGF, HGD and HGC Series Gas Fryers are available in various sizes, with an array of features and options for a range of commercial fryer applications. The overall tank widths on the 35 and 45 models are the same. The 65 models have a larger tank capacity than the 45 models. The 65 and 85 models are the same width. The 85 models are deeper and have a larger tank capacity than the 65 models.
The HGD models have digital controls and a solid state thermostat. The HGC Fryers have a microprocessor (computer) control and timer.

Before installing the fryer, verify that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel. Ensure the fryer is configured for the proper elevation.
This fryer was carefully inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment.
Immediately after unpacking the fryer, check for the following items:
Stand-A-Lone Fryer Only Filter-In-A-Drawer Fryer Only
In addition, check for possible shipping damage. If the fryer is damaged, save the packaging material and contact the carrier within 15 days of delivery.
Do not use the door or its handle to lift the fryer.
The equipment area must be kept free and clear of combustible substances. Minimum clearance from combustible construction is 6" (15 cm) from the sides and 6" (15 cm) from the back of the fryer. Minimum clearance from noncombustible construction is 0" from the sides and 0" from the back.
At least 16" (41 cm) clearance must be between the fryer and any open-top flame units. Adequate clearances for servicing and proper operation must be allowed. The fryer may be installed on combustible floors.
Install the fryer in an area with sufficient air supply for combustion of the gas at the fryer burners. Provide adequate clearance for air openings into the combustion chamber. Do not obstruct the flow of combustion and ventilation air. Do not permit fans to blow directly on the fryer. Avoid wall-type fans which create cross-currents within a room. Avoid open windows next to the sides or back.

Hobart fryers must be installed in accordance with:
In the United States of America:
In Canada:
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6.
When installed, the fryer must be restrained to prevent tipping to avoid the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances or installing the fryer in an alcove, or by separate means, such as adequate ties.
Fryers Mounted on Legs (Non-Batteried Fryers)
Fryers serviced from the rear must have a minimum clearance of 18" (46 cm) from the wall when mounted on legs.
Fryers Mounted on Casters
If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect this restraint prior to turning the gas supply on and returning the fryer to its installation position.

Separate instructions for installing casters to the fryer are included with the casters.

GAS CONNECTIONS
The gas inlet is located on the lower right rear of the fryer. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer.
The gas supply line must be at least the equivalent of 1/2" iron pipe for single units and 1 1/4" for batteries. If using the optional quick-disconnect flex hose: 3/4" iron pipe for single units and 1 1/4" iron pipe for batteries.
Make sure the pipes are clean and free of obstructions, dirt and piping compound. A battery requires one or two connections of appropriate size and type for the gas requirement.
After piping has been checked for leaks, fully purge gas pipes to remove air.
The gas pressure should be set at 4" W.C. (Water Column) (1 kPa) pressure for natural gas and 10" W.C. (2.46 kPa) pressure for propane gas. If incoming pressure exceeds 1/2 psig (3.45 kPa), an additional pressure regulator must be installed.
When test pressures exceed 1/2 psig (3.45 kPa), the fryer and its individual shutoff valve must be disconnected from the gas supply piping system.
When test pressures are 1/2 psig (3.45 kPa) or less, the fryer must be isolated from the gas supply piping system by closing its individual shutoff valve.

The fryer must be located under a hood with adequate connection to an exhaust duct. The hood must extend 6" (15 cm) beyond fryer sides.
Adequate ventilation must be provided and comply with Vapor Removal from Cooking Equipment, ANSI-NFPA Standard #96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Clearance above the fryer should be adequate for combustion by-products to be removed efficiently. An 18" (46 cm) minimum clearance should be maintained between the flue vent and the filters of the hood venting system. Never make flue connections directly to the fryer.
Do not obstruct the flow of the flue gases from the appliance. Proper air balance should be maintained in the room.
Fryers are equipped with a 120 V, 60 Hz, 1-phase cord and plug.
Do not connect fryer to electrical supply until after gas connections have been made.

Liquid shortening may be used in all HGF, HGD or HGC Series Fryers. Solid shortening can only be used in fryers equipped with a melt cycle. Melting solid shortening without using a melt cycle will damage the fry tank and scorch the shortening. See Melt Options in this manual under your particular model for more information. Make sure the gas valve is off when draining or filling.


HGF FRYER CONTROLS Thermostat Knob - Used to control frying temperature.
Gas Valve Knob - Used to ignite and operate the pilot.
LIGHTING INSTRUCTIONS FOR HGF FRYER WITH MANUAL PILOT IGNITION CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening.

If pilot does not remain lit, repeat Steps 2, 3, and 4.


Fig. 6 Fig. 7
TURNING THE FRYER ON To turn the fryer on, set the thermostat knob to the desired temperature. After the set temperature has been reached, the gas control shuts off gas flow to the burners. The pilot remains lit. The burners will cycle on and off, maintaining the set temperature.
TURNING THE FRYER OFF 1. Turn the thermostat OFF.
EXTENDED SHUTDOWN 1. Turn the mainl gas shutoff valve OFF.

Gas Valve Extension Arm - Used to ignite and operate the pilot.
LIGHTING INSTRUCTIONS FOR MANUAL PILOT IGNITION (HGFD & HGFC SERIES)

SHUTDOWN INSTRUCTIONS WITH MANUAL PILOT IGNITION (HGFD & HGFC SERIES)
EXTENDED SHUTDOWN FOR MANUAL PILOT IGNITION FRYER (HGFD & HGFC SERIES)


EXTENDED SHUTDOWN FOR ELECTRONIC IGNITION FRYER (HGFD & HGFC SERIES)

HGFD Series Fryers are equipped with digital controls and a solid state thermostat.

Control Guide

Temperature, time, energy source and other parameters must be set before operating. Once these parameters are set, the fryer can be operated at the touch of a button.
to enter the program mode and scroll through the parameters. If the Parameter Lock feature
is on, LoC is displayed in the window and program entry cannot be accessed. To access the program
mode while LoC is on, press
UP
within 6 seconds of pressing
. To turn the Parameter
Lock feature off, see Program Guide below.
Once in the program mode, the parameters are displayed in the order listed below. To exit the program
and save changes, press and hold
for approximately 2 seconds.

LED is lit above the left basket icon. The time value is displayed
LED is lit above the right basket icon. The time value is displayed
* = Default setting
Press · Programming Guide

Melt Options (HGD Series)
When using solid shortening in the fryer, the CY S (solid shortening) option must be used. Solid shortening must be gently warmed to a liquid state before heating to frying temperatures. Melting solid shortening without using this option will damage the fry tank and scorch the shortening.
The controller has three options for bring shortening up to temperature:
*CY L (Liquid shortening) - For slowly bringing liquid shortening up to temperature.
CY S (Solid shortening) - For slowly melting solid shortening.
CY O (No melt) - For immediately bringing liquid shortening up to fry temperature.
Upon startup, if the CY L or CY S melt option is selected and the shortening temperature is below 135°F (57°C), CY is displayed in the window and the fryer cycles to bring the shortening up to temperature. If the shortening temperature is over 135°F (57°C), HEAT is displayed in the window and the fryer quickly heats up to set temperature.
The temperature is displayed in the window when the fryer has reached the set temperature. After the first initial startup, the fryer always defaults to the last entered melt option.
* = Default setting
USING THE FRYER (After Startup)
Models Without Basket Lift Option
to start the right timer.
Press to silence the right timer beeper.
Models With Basket Lift Option
Press to lower the left basket. Press
to lower the right basket. The timer(s) begin
counting down.

When the timer times out, a beeper sounds and the basket(s) automatically raise. Press
to silence the left timer beeper. Press
to silence the right timer beeper.
Press to lower the right basket. The timer begins counting down. When the timer times
out, a beeper sounds and the basket automatically raises. Press to silence the right timer
beeper.

HGFC Series Fryers have a microprocessor (computer) thermostat and timer.


For turning on or off the filter pump when supplied with built in filtering system.
Initiates program cooking cycles for units with or without basketlifts.
Control Guide

Temperature, time and other parameters must be set before operating. Follow the Program Guide to configure the fryer to your particular operation.
to enter into the program mode, then follow the steps under each parameter to enter the
desired information. To exit the parameter and save changes, press
. To exit the program
again.
Press DEGREES F or C F or C
Press to select Fahrenheit or Celsius. DEGREES F or C F or C
Press when complete. PROGRAM
Press SET PASS NEW PASS
Press to select NO PASS. NO PASS NEW PASS
Press when complete. PROGRAM
Press SET PASS NEW PASS
Press to select PASS REQ. PASS REQ NEW PASS
Press and enter numeric code. CODE XXXX NEW PASS
Press when complete. PROGRAM
Press SELECT OPTIONS OPTIONS
Press VOLUME # BEEPER
Press to select volume. 1, 2 or 3 BEEPER
Press when complete. PROGRAM

Programming Guide (cont.)
Press ENGLISH (Factory Default) LANGUAGE
Press to select a language. ENGLISH/ESPANOL FRANCAIS/DEUTSCH HOLLAND
Press when complete. PROGRAM
Press to select melt options. NO MELT/LIQUID/SOLID
Press when complete. PROGRAM
Press when complete. PROGRAM
Press SELECT OPTIONS OPTIONS
Press FILTER PROG 0000
Press to scroll through options. FILTER ACT 0000
Press when complete. PROGRAM
Press DISPOSE PROG 00
Press to scroll through options. DISPOSE ACT00
Press when complete. PROGRAM
Press Enter 11-99 min. of idle time IDLE SET BACK PROG 00
Press when complete. PROGRAM PROG 00
*Recovery - During a cold start, the controller measures the time the fryer takes to heat from 200°F to 250°F (93°C to 121°C) and compares it with factory default values.

When using solid shortening in the fryer, the SOLID melt option must be used. Solid shortening must be gently warmed to a liquid state before heating to frying temperatures. Melting solid shortening without using this option will damage the fry tank and scorch the shortening.
The controller has three options for bring shortening up to temperature. Upon startup, the fryer will display the selected melt option in the window when heating:
HEATING NO MELT - For immediately bringing shortening up to fry temperature.
MELT L LIQUID - For slowly bringing liquid shortening up to temperature.
MELT S SOLID - For slowly melting solid shortening.
If the LIQUID or SOLID melt option is selected and the shortening temperature is below 135°F (57°C), MELT L or MELT S is displayed in the window and the fryer cycles to bring the shortening up to temperature. If the shortening temperature is over 135°F (57°C), HEATING is displayed in the window and the fryer quickly heats up to set temperature.
The temperature is displayed in the window when the fryer has reached the set temperature. After the first initial startup, the fryer always defaults to the last entered melt option.
The Filter parameter can be programed to alert the operator to filter the shortening by counting the number of cook counts. When the actual cook count is the same as the programmed cook count, FILTER flashes in the window. It also can be programmed to time the filtering process.
starts the filter timer after the shortening is drained. (Drain valve open).
The controller can also be programmed to alert the operator to dispose of the shortening by counting the number of times the shortening is filtered. When the filter count is the same as the programmed filter count, DISPOSE is displayed in the window.
Melt Options · Filter · Dispose

See Daily Filtering section in this manual for more information.
to enter program mode. PROGRAM is displayed in the window.
to enter temperature mode. 000°F and TEMP are displayed in the window.
to enter desired fry temperature. The fry temperature is displayed in the
window.
to exit the temperature mode. Press again to exit program mode completely.
There are ten timers with advanced timing features on the HGC fryer for setting fry times on multiple products.
:
and enter the program mode. PROGRAM is displayed in the window.
are lit and SELECT PRODUCT is displayed in the window.
. The LED's on timers
. The time is displayed in the window. After
entering the time, press
; SELECT PRODUCT is displayed in the window and the LED's on
are lit.
to exit the program completely.

:
and enter the program mode. PROGRAM is displayed in the window.
. The LED's on timers
are lit and SELECT PRODUCT is displayed
in the window.
. The time is displayed in the window. After
entering the time, press
; SELECT PRODUCT is displayed in the window and the LED's on
are lit.
to exit the program completely.
Each timer has additional timing functions that can be programmed to fit your particular operation.

Setting Advanced Time Features
and enter the program mode.
. The LEDs are
lit on the timers available for programming, and SELECT PRODUCT is displayed in the window.
A. Duty Time:
; DT# 00:00 is displayed in the window.
. The time is displayed in the window.
to choose another timer.
B. Hold Time:
; HD# 00:00 is displayed in the window.
to choose another timer.
C. Compensated or Straight Time:
; COMP or STRAIGHT is displayed in the window.
to select COMP or STRAIGHT.
to exit program mode completely.
to choose another timer or press

Time Programming Quick Chart

to enter the program mode
Exit Program Enter Time
Select COMP or STRAIGHT

USING THE FRYER (After Startup)
Models Without Basket Lift Option
programmed for products. Once the product is selected, select
button to start timing
of the product on the left or right side of the fryer.
Models With One Basket Lift Option
are programmed for products.
Once the product is selected, the timing will start and the single basket lift will lower the product into the shortening.
Models With Two Basket Lift Option
programmed for products. Once the product is selected, select
button to start timing
of the product on the left or right side of the fryer.

Fry Basket Guidelines

Sizes Total Lbs. of Product Total Lbs. of Product Total Lbs. of Product (1 Basket) (2 Baskets) (3 Baskets)
35 1 1/2 (0.7 kg) 3 (1.4 kg) N/A
45 2 1/2 (1.1 kg) 5 (2.3 kg) N/A
65 3 (1.4 kg) 6 (2.7 kg) 9 (4.1 kg)
85 3 1/2 (1.6 kg) 7 (3.2 kg) 10 1/2 (4.8 kg)
Filtering Guidelines (All Models)

Filter-Ready Fryers (For Use With Mobile Filter Only)
Recommended Basket Capacities

Battery Interplumbing (Available Only on Filter-In-A-Drawer Models)
A battery of fryers equipped with optional interplumbing connects the fry tanks to a common drain. Each tank has an individual drain valve. Only one tank can be filtered at a time. Instructions for the Filter-In- A-Drawer are covered in a separate manual. Follow the instructions.
Filtering Procedures (Non-Filter-Ready Fryers)
DRAIN INTERLOCK (HGD and HGC Series)
Prevents the burners from operating when the drain valve is open.
SHORTENING LIFE (All Models)
Shortening life can be extended by following these guidelines:


Fryers should be kept on a regular preventive maintenance schedule. Contact your local Hobart Service office for details.
Motors used on basket lifts are permanently lubricated.
When the fryer is cool, inspect annually. Check the flue and clear any obstructions.
To obtain service and parts information concerning this model, contact your local Hobart Service office.
When calling for service, the following information must be available: model number, serial number, manufacture date (MD) and voltage.

POSSIBLE CAUSES / SOLUTIONS
No power when switch is turned on.
Tripped breaker; fuse blown / Verify fryer is plugged in and outlet has power. Check power cord connection at the power supply box.
Problem with power switch / Call service.
Fryer will not heat.
Gas supply not on or partially on / Verify gas supply valve is full on / Check hose connection (if applicable).
Verify power is on.
Gas valve in fryer not on / Verify gas valve is on in fryer / Verify pilot comes on.
Problem with high limit / Call service.
Problem with electrical system / Turn off gas supply and call service.
Combination valve is stuck in open position / Turn off gas supply and call service.
Fryer continues to heat.
Problem with electrical system / Call service.
Fryer heats, but will not reach desired temperature.
Gas supply pressure inadequate / Call service.
Fryer stops heating during operation.
Tripped breaker, fuse blown / Verify fryer is plugged in and check circuit breakers and fuse(s).
Check gas supply. Verify pilot is on.
Shortening is too hot, high limit switch is open / Call service.

ALARMS AND ERROR MESSAGES (HGD and HGC Series)
Pilot Out - If the pilot is out, the control displays the following message: (Electronic ignition only)
HGD Series - FIrE OUt
HGC Series - PILOT OUT
If no action is taken after 90 seconds, an alarm sounds continuously, the heat demand is disabled and any running cooking cycles are cancelled. The control displays the following message:
HGD Series - Ign LoC
HGC Series - IGNITION LOCKOUT
The fryer must be turned off, then back on before the pilot can be relit and normal fryer functions resumed. See pages 10 and/or 11 for lighting instructions pertaining to your particular model.
Open Probe - If an open probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:
HGD Series - Prob
HGC Series - OPEN PROBE
The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. If the problem persists, call service.
Shorted Probe - If a shorted probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:
HGD Series - Hi
HGC Series - SHORTED PROBE
The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. If the problem persists, call service.
Hi Temperature - If the temperature is greater than or equal to 415°F (212°C), the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:
HGD Series - Hi
HGC Series - SHORTED PROBE
The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. Normal fryer operations resumes when temperature drops below 415°F (212°C). If the problem persists, call service.

– 32 – FORM 35643 Rev. A (Apr. 2005) PRINTED IN U.S.A.
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No power when switch is turned on. | Tripped breaker; fuse blown / Verify fryer is plugged in and outlet has power. Check power cord connection at the power supply box. Problem with power switch / Call service. | p.30 | |
| Fryer will not heat. | Gas supply not on or partially on / Verify gas supply valve is full on / Check hose connection (if applicable). Verify power is on. Gas valve in fryer not on / Verify gas valve is on in fryer / Verify pilot comes on. Problem with high limit / Call service. Problem with electrical system / Turn off gas supply and call service. | p.30 | |
| Fryer continues to heat. | Combination valve is stuck in open position / Turn off gas supply and call service. Problem with electrical system / Call service. | p.30 | |
| Fryer heats, but will not reach desired temperature. | Gas supply pressure inadequate / Call service. | p.30 | |
| Fryer stops heating during operation. | Tripped breaker, fuse blown / Verify fryer is plugged in and check circuit breakers and fuse(s). Check gas supply. Verify pilot is on. Shortening is too hot, high limit switch is open / Call service. | p.30 |