Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 1 Model(s): CNXT4236IT CNXT4842IT CNXT4236IH CNXT4842IH CNXT4236IL T CNXT4842IL T CNXT4236ILH CNXT4842ILH Direct V ent Gas Appliance Owner ’ s Manual Installation and Operation Installation and service of this appliance should be performed by quali fi ed personnel.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: ________________.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 4 = Contains updated information. 13 Finishing A. Mantel and W all Projections 59 B. Facing Material 59 14 Appliance Setup A. Remove Glass Assembly 60 B. Remove the Shipping Materials 60 C.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 5 B. W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands .
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 6 B. W arranty (continued) This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 7 C. BTU Speci fi cations MODELS: CNXT4236IT , CNXT4842IT , CNXT4236IH, CNXT4842IH, CNXT4236IL T , CNXT4842IL T , CNXT4236ILH, CNXT4842ILH LABORA TOR Y : Underwriters Laboratories, Inc.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every d.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 9 Decorative Doors (not shown) Section 2.E. Fixed Glass Assembly (not shown) Section 2.F . Grate (not shown) Section 3.B. Mantel Hearth (not required) Clear Space Section 2.D. Fan Kits Section 2.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 10 Clear space 3 ft (914 mm) in front of appliance D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 1 1 I. Lighting Instructions (IPI) • For normal use, activate/deactivate your fi replace with the wall switch or remote control. • The IPI system may be operated with two D-cell batteries.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly .
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 14 Burner Ignition and Operation Frequency: Annually By: Quali fi ed Service T echnician T ools needed : Protective gloves, vacuum cleaner , whisk broom, fl ashlight, voltmeter , indexed drill bit set, and a manometer .
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 15 Noncombustible roof flashing maintains minimum clearance around pipe (SECTION 10) Ceiling Firestop on floor of attic (SECTION 8) V e.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 16 B. Design and Installation Considerations Heatilator direct vent gas appliances are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 17 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 18 Combustible flooring may be installed next to the front of the appliance. C B A 1/2 in. (13 mm) 1/2 in. (13 mm) Drywall 0 in. 30 in. (762 mm) to ceiling D 0 in. to floor 0 in. to level of standoffs Combustible Object 36 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 19 Measured from top of hood (in inches) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 6 10-1/4 11 1 1-3/4 12-1/2 13-1/4 14 14-3/4 15-1/2 16-1/4 17 17-3/4 18-1/2 19-1/4 20 20-3/4 30 in. minimum to ceiling D.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 20 A. V ent T ermination Minimum Clearances Figure 6.1 Minimum Height From Roof T o Lowest Discharge Opening Horizontal overhang 12 X 20 in. (508 mm) Lowest Discharge Opening T ermination Cap Roof Pitch is X / 12 V ertical wall H (min.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 21 Dimension Descriptions A Clearance above the ground, a veranda, porch, deck or balcony - 12 in. (30 cm) minimum. * B Clearance to window or door that may be opened – 10,000 BTUs or less, 6 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 22 Horizontal V ertical 8-1/2 in. 8-1/2 in. 12 in. On 45° runs, 1 ft (.3 m) of diagonal is equal to 8-1/2 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 23 H 1 V 1 T o replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows can be replaced with two 45° elbows. General Rules: • SUBTRACT 3 ft. from the total H measurement for each 90° elbow installed horizontally .
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 24 4 ft min. (1.22 m) 25 ft max. (7.62 m) H 1 V 1 H 2 H 3 Installed Horizontally Installed V ertically H 2 Figure 7.5 T wo Elbows 1. T op V ent - Horizontal T ermination - (continued) Figure 7.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 25 Figure 7.6 1. T op V ent - Horizontal T ermination - (continued) Three Elbows H 1 V 1 V 2 H 2 Installed V ertically V 1 min. V 1 + V 2 max. H 1 +H 2 max. ft m ft m ft m DVP 1 0.30 24 7.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 26 2. T op V ent - V ertical T ermination No Elbow Figure 7.7 Figure 7.8 T wo Elbows Note: If installing a vertical vent/ termination off the top of the appli- ance, the vertical termination baf fl e should be used.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 27 Figure 7.9 2. T op V ent - V ertical T ermination - (continued) Three Elbows 12 ft (3.66 m) min. 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 28 3. Rear V ent - Horizontal T ermination Figure 7.10 Figure 7.1 1 No Elbow One 45° Elbow 18 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 29 3. Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.12 Figure 7.13 Three Elbows H 2 V 1 H 1 H 2 V 1 H 3 H 1 Installed Horizontally H 1 max. V 1 min. H 1 +H 2 max.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 30 4. Rear V ent - V ertical T ermination One Elbow Figure 7.14 T wo Elbows Figure 7.15 12 ft (3.66 m) min. 60 ft (18.29 m) max. 0 min. 6 ft (1.83 m) max. 12 ft (3.66 m) min. 60 ft (18.29 m) max.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 31 4. Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.16 12 ft (3.66 m) min. 60 ft (18.29 m) max. 0 min. 6 ft (1.83 m) max. Maximum horizontal run is 100% of vertical, but can- not exceed 26 ft (7.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 32 F . Installing V ertical T ermination Baf fl e • Remove the glass (refer to Section 14.H.) to access the fi rebox and 5 in. inner fl ue. • Fold the baf fl e (Figure 7.17) to an approximate 90° angle (see Figure 7.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 33 • Squeeze the open end of the bent baf fl e with one hand. Insert the baf fl e bent side up into the inner fl ue so that the bottom of the baf fl e is above the bead on the inside of the collar .
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 34 B* Framing should be constructed of 2 X 4 lumber or heavier . The center of the framing hole is 1 in. (25mm) above the center of the horizontal vent pipe. A* V ent framing hole. DO NO T P ACK WITH INSULA TION OR OTHER MA TERIAL.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 35 3 fasteners per side Ceiling firestop installed below ceiling. Ceiling firestop installed above ceiling. Install attic insula- tion shields before or after installation of vent system.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 36 Bend all tabs inward 90° to maintain clearance and prevent insulation from falling inside Insert 3 screws Bend 4 tabs inward 90° to maintain clearance D. Install Attic Insulation Shield W ARNING! Fire Risk.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 37 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installa- tion. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 38 • Remove four screws holding outer collar to appliance top. See Figure 9.5. Remove outer collar . Figure 9.5 Outer Collar , Remove Four Screws • Remove four screws holding inner collar to appliance top.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 39 Figure 9.1 1 Place Outer Collar on Rear of Appliance • Place outer collar on rear of appliance and replace four screws to hold collar in place. See Figure 9.1 1. Make sure insulation is attached to the collar base! Figure 9.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 40 Figure 9.16 Cover Plate-Replace Figure 9.17 Place Cover Plate on T op of Appliance • Locate heat shield cover plate removed in the fi rst step. Place the heat shield cover plate on top of heat shield.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 41 Nailing T abs (both sides) B. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 42 Lances 1 0 10 Installing V ent Pipe A. Assemble Pipe Sections (DVP Only) Attach Pipe to the Firebox Assembly Note: The end of the pipe sec tions with the lanc ed tabs will face towards the applianc e.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 43 B. Assemble V ent Sections (SLP Only) T o attach the fi rst vent component to the starting collars of the appliance • Attach an SLP-DVP24 adapter to the starting collar of the appliance.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 44 C. Assemble Slip Sections W ARNING! Risk of Fire or Asphyxiation! Overlap pipe sections at least 1 1/2 in. (38 mm). Secure slip sections with two screws which must not exceed 1/2 in. (13 mm) in length.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 45 E. Disassemble V ent Sections • Rotate either section (see Figure 10.1 1) so the seams on both pipe sections are aligned as shown in Figure 10.12. • Pull carefully to separate the pieces of pipe.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 46 G. Install Metal Roof Flashing Note: Skip to Section I if using the RF4 - 8. • See minimum vent heights for various pitched roofs (Figure 10.15) to determine the length of pipe to extend through the roof.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 47 H. Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installa- tion. Sheet metal edges are sharp. • Connect both halves of the storm collar with two screws (see Figure 10.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 48 I. Install RF4-8 The RF4-8 may be used in place of the roof fl ashing and storm collar (Sections 10.H. and 10.I.) Pipe must be supported within 12 in. (305 mm) of the roo fl ine using plumbers strapping or an SLP-FS when us- ing the RF4-8 Flashing.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 49 J. Installing V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar of the cap over the outer fl ue of the pipe section.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 50 Figure 10.26 V enting through the wall Note: When using terminati on caps with fac tor y-supplied heat shield att ached, no additional wall shield fi restop is required on the exter ior side of a combust ible wall.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 51 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 52 1 2 12 Elec tric al Informat ion A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 53 E. WSK-ML T Multifunction W all Switch The WSK-ML T multifunctional wall switch is designed to control fl ame height, blower speed and auxilary func- tions on your gas fi replace.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 54 Wiring the W all Switch • Install the provided control wire from the fi replace to the switch location. (Control wire for Heatilator products is supplied with the fi replace). NOTICE: Do not to stress the wire around tight or sharp corners.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 55 F . Install the Flame Solenoid Gas Control Va l v e V ariable Regulator Flame Control Solenoid W asher V ariable Regulator V ariable Regulator W asher Plunger Jam Nut Nut Screw Knob Solenoid Figure 12.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 56 H. Install the Remote Cover Plate The remote cover plate shipped in the bottom of the appliance MUST be placed over the control plate before operating the appliance. Not doing so may result in over- heating the controls on the plate.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 57 I. WSK-ML T Operating Instructions The ON/OFF rocker switch in the fi replace (located near the gas valve) must be in the “OFF” position for use with the WSK-ML T system.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 58 Child Proof Mode T o Enter Child Proof Mode: • Press the Up Arrow Button twice and Down Arrow Button once. The unit will send out three beeps and an indicator in the LCD panel will show that the child proof is on.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 59 1 in. (25 mm) min. to perpendicular wall A 3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall B Mantel Leg or Perpe.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 60 1 4 14 Applianc e Setup A. Remove Glass Assembly See Section 12.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 61 G. Log Assembly • Base logs have been permanently mounted on the grate assembly and should not be moved. Place the Rockwool • See Figures 14.1 and 14.4. • Place a small amount of 1/2 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 62 Latches (both bottom and top) Glass Assembly Closed J. Install Hood • Align back edge of hood with attachment clips and press fi rmly into place. Figure 14.8 Fixed Glass Assembly H.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 63 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 64 A. Intelli fi re Ignition System (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but continues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 65 1 6 16 Reference Materials B 38 in. (965 mm) 1-1/2 in. (38 mm) 26-1/2 in. (673 mm) 2-1/2 in. (64 mm) 6 in. (152 mm) 14-3/8 in. (365 mm) Electric Access 3-5/8 in. (92 mm) 6-3/8 in. (162mm) Gas Line Access 9-1/4 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 66 B. V ent Components Diagrams Figure 16.2 DVP V ent Components Effective Height/Length DVP Pipe (see chart) Pi p e inches mm DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 - 6 76 - 152 DVP12A 3 - 12 76 - 305 Effective Height/Length 10-1/2 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 67 B. V ent Components Diagrams ( continued ) Figure 16.3 DVP V ent Components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (698 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 68 B. V ent Components Diagrams ( continued ) Figure 16.4 DVP V ent Components DVP-TB1 Basement V ent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 10-1/2 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 69 B. V ent Components Diagrams ( continued ) Figure 16.5 DVP V ent Components DVP-TRAP1 DVP-TRAP2 DVP-HPC1 DVP-HPC2 DVP-TRAPK1 DVP-TRAPK2 DVP-TRAP Horizontal T ermination Cap 15-1/8 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 70 B. V ent Components Diagrams (continued) Figure 16.6 DVP V ent Components 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) DVP-HRC-SS 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 71 B. V ent Components Diagrams (continued) Figure 16.7 SLP Series V ent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 72 B. V ent Components Diagrams (continued) Figure 16.8 SLP Series V ent Components SL-2DVP Adapter SLK-SNKD Snorkel T ermination Cap S.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 73 Service Parts 09/08 Service Parts Diagram 36 in. Caliber NXT Series CNXT4236IT , CNXT4236IH Part number list on following page. Log Set Assembly 3 1 6 2 5 4 8 10 11 12 16 28 20 22 19 23 21 7 (V alve Assy .
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 74 Service Parts 09/08 Service Parts Diagram and List 36 in. Caliber NXT Series CNXT4236IT , CNXT4236IH Beginning Manufacturing Date: J.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 75 Service Parts 09/08 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 76 C. Service Parts (continued) Service Parts 06/08 Service Parts Diagram 42 in. Caliber NXT Series CNXT4842 SERIES Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active 8 3 12 4 2 20 7 6 19 1 5 22 (V alve Assy .
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 77 C. Service Parts (continued) Service Parts 06/08 Service Parts Diagram 42 in. Caliber NXT Series CNXT4842 SERIES Beginning Manufactu.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 78 C. Service Parts (continued) Service Parts 06/08 Service Parts List 42 in. Caliber NXT Series CNXT4842 SERIES Beginning Manufacturin.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 79 D. Optional Components Arts & Crafts Faux Front FFCAC Modernist Faux Front FFCM Jamestown Faux Front FFCJ WTBC36D 36 in. Weathered Brick Refractory Liner Kit WTBC42D 42 in. Weathered Brick Refractory Liner Kit CNXT4842 47 in.
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 1 1/08 80 E. Contact Information Please contact your Heatilator dealer with any questions or concerns.
An important point after buying a device Hearth and Home Technologies CNXT4842ILH (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hearth and Home Technologies CNXT4842ILH yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hearth and Home Technologies CNXT4842ILH - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hearth and Home Technologies CNXT4842ILH you will learn all the available features of the product, as well as information on its operation. The information that you get Hearth and Home Technologies CNXT4842ILH will certainly help you make a decision on the purchase.
If you already are a holder of Hearth and Home Technologies CNXT4842ILH, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hearth and Home Technologies CNXT4842ILH.
However, one of the most important roles played by the user manual is to help in solving problems with Hearth and Home Technologies CNXT4842ILH. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hearth and Home Technologies CNXT4842ILH along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center