Instruction/ maintenance manual of the product Conquest Gas Stove Harman Stove Company
Go to page of 30
1 A B C R 1 SA FE T Y N OTICE PLEASE RE A D TH I S EN TI RE M AN U A L BEFORE Y O U I N S T ALL AN D U SE YO U R N EW RO OM H EA TER. F AI LU RE T O FOLLOW I N STRU C TIO N S MA Y R ESU L T IN PROPER TY DAM AG E, B ODI L Y I N JU R Y , OR EV EN DEA TH .
2 CAU T ION: Do no t op erate th e ap p l i an ce wi th g l ass r em oved, crack ed or bro k en. Rep l acemen t o f th e pa n el (s) s ho u l d be d one by a l i ce nse d o r qu a l i f i ed se rv i ce p e r son.
3 T ab le of Con te n ts Intro d u ct ion 4 Saf ety Precautio ns 4 Ope ra ti o n 5 Specifi cat io ns 7 C lea r ance s 8 Ins ta l lat ion 9 V en ting 1 0 C ha ng ing T o Natura l G as 14 Opt ion Ins t .
4 I n tro du ct i on T h e H ar m a n Conque st D i r e ct V en t G as S tov e i s a l i sted gas-f i re d di rect vent roo m fi repl ace tes ted b y Intertek T esti n g Serv i ce s/W ar no ck Her sey to ANSI Z 2 1.88-2 0 0 2 , C SA 2 .33- M02 a n d C A NL /C GA - 2.
5 OP E R A T ION Op e r a t i on H OW TO LI G H T TH E F IRE 1. S T OP! R ead th e saf ety i n form ati on o n the fr o nt co v er o f th i s m anu al . 2. If us i ng t he op ti o nal thermo st at, s et thermo stat to the l owest setti ng. 3. T urn o ff el ectri c p ower to th e op ti on al bl o wer .
6 OP E R A T ION 15 . Set th e Hi g h-Low Regul ator to des i r ed s etti ng: T u rn ful l y co un tercl o ckwi s e f o r Hi gh an d fu l l y cl ockwi s e f o r L o w .
7 SP E CIFI C A TI O NS RA T I NG S N A T UR AL PROP AN E Inp u t R at ing (Bt u /h r)(0-4 50 0 f t.)(0 -137 5 m ) 2 9 000 2 9 000 Min . In pu t Rati n g (Btu /hr)(0-450 0 f t.)(0 -137 5 m ) 1 4 900 1 4 100 Orifi ce s (DMS)(0-45 00 f t.)( 0-13 75 m ) 3 7 5 3 Man ifo l d Pres sure (i n w .
8 SP E CIFI C A TI O NS MI NIM UM C LEARANC ES F ROM C OMB UST IB LE C O NST RUC T IO N U ni t to corner wal l s 2 in. U ni t to si de wal l 8 in. U ni t to back wal l 3 in. U ni t to al co v e cei l ing 16 i n. Maxi m um al c o v e dep th 16 i n. El e ctri ca l Rati n g : 1 20 V olts, 6 0 Hz, > .
9 I N ST AL LA T I ON Onl y Fo r Qua li fied In stal lers Burn Only the Fuel for which the H ea ter is Equ i pped T h e Co nqu es t ca n b u r n ei th er n atur al g as o r pr o- pan e, bu t r equ i res a ch ange- o v er ki t for natu ral ga s. T h e l ab el o n the b u rner sy st em mo d ul e indica tes the fuel fo r whi ch i t i s equ i pp ed.
1 0 I N ST AL LA T I ON Onl y Fo r Qua li fied In stal lers 6-5 /8 x 4 8” x 5” Des cription n/ a 1208 6” Pi pe Length 908B 12 08B 6 ” Pi pe Length, Bl ack n/ a 1207 9” Pi pe Length 907B 12 0.
1 1 I N ST AL LA T I ON Onl y Fo r Qua li fied In stal lers Ma ximum o f f ou r 45 0 elbo ws a llo wed. Su b tract th r e e feet of to ta l ho rizon ta l pip e leng th for each of the 3r d an d 4 th 45 0 elbo ws used . Ma ximum o f t wo 9 0 0 e lb ows allo wed.
1 2 I N ST AL LA T I ON Onl y Fo r Qua li fied In stal lers Requirements fo r T erminat ing t he V enting W ARNING: V en ti ng ter m i nal s mu st n ot b e r e- cessed i nto a wal l o r s i di ng. In a ddition, t he follo wing mu s t b e obs erv ed: A.
1 3 I N ST AL LA T I ON Onl y Fo r Qua li fied In stal lers Na tura l Ga s or P ropa ne 0 F eet ( rea r V ent) Open 6 feet 1/ 4 to O pen 12 fee t 1/ 4 to O pen 24 feet C lo s ed to 1 /2 36 feet C lo s ed to 1 /2 Ra ng e O f Appro v ed D amper Set tings A v ent dam p er i s p rovi ded to al low fi ne tu ning of th e d r aft.
1 4 I N ST AL LA T I ON Onl y Fo r Qua li fied In stal lers Ch an g ing to N atu r a l G as Remove p ilo t tower with a 7 /1 6” wr ench. Repla ce LP orif ice with Natu ral Gas orif ice .
1 5 I N ST AL LA T I ON Onl y Fo r Qua li fied In stal lers Pla ce con ve rsion sticker ( p r ovid ed in K it) on th e valve. Th is is to p er man ent ly m a rk th e valve tha t it h as been con ver ted to Natu ral Ga s. Th is lab el is imp orta n t in the e vent tha t th e valve is eve r r emoved a nd mixe d in wit h o th er valves.
1 6 I N ST AL LA T I ON Onl y Fo r Qua li fied In stal lers Rear Log Fr ont L og Pla ce th e r e ar log beh in d th e fr on t lo g with the bra nch r e stin g o n th e fr on t lo g on th e r ig h t sid e as sho wn. Pla ce th e fr on t lo g a s sho wn between the an d ir on s a nd the ai r deflector .
1 7 I N ST AL LA T I ON Onl y Fo r Qua li fied In stal lers T ile K it Each ti l e ki t con tai ns six ti l es and fi fteen al l en - set screw s. If t he Co nq u est i s i nstal l ed as a to p vent, th en th e rou nd ti l e i s n o t us ed. If i t i s i ns tal l ed as a rear v ent, th en th e tr i m ri ng i s no t us ed.
1 8 I N ST AL LA TI ON (Optio ns) Onl y Fo r Qua li fied In stal lers C o nnecting the Opt iona l T hermos ta t I f the o pti o nal therm os tat i s used , i t m us t be plugg ed i nt o th e T H ter m i nal s l ocated on the valve. Wh en i n stal l i n g a m i l l i vol t con trol sys tem, us e on l y a s peci al l ow resi stance th ermo stat.
1 9 I N ST AL LA TI ON (Optio ns) Onl y Fo r Qua li fied In stal lers Op ti onal Blow e r T h e B l ower Ki t ( Part # 1-0 0 -0 9 10 2 ) i ncl u des a blower ass emb l y ready to bo l t to th e l eft si d e of th e sto ve and a bl o wer cham ber cover .
2 0 M A I NT E NAN CE Removing the G las s F ront Rem o v e the ai r gri ll b y pu l l i n g fo r ward. Li f t t he l atch sho wn ab ov e and ti l t th e g l ass d oo r ou t at t he to p and l i f t o ff th e ho o k s at t he b ot tom . Hand l e the gl as s wi th care.
2 1 M A I NT E NAN CE Ai r In Ai r Ou t T he flo w o f co mbus tio n a nd v entila tio n air mus t not b e obs tructed. C lea ning t he Burners T o c l ean t h e bu rn ers, you m us t remo v e th e g l ass do o r , l ogs, an d bu rner screen. W i th th ese parts remo ve d , i ns pect al l th e h ol es to m ake sure th ey are un o bs tructed .
2 2 M A I NT E NAN CE TH TH V al ve ON/OFF S wit ch Blo wer Sp eed Con tr ol T emperatu r e Sw i tch Po wer Cor d Op ti onal B lo w e r W ir ing Dia gram ( 12 0 V ol t ) Low V olt a ge W i ring Di a g ra m “Ca u ti on: Label al l wi r e s p r ior to di sc o n n e c ti on wh e n ser vi c i n g c o n tr o l s.
23 Ho mo log ue Pou r Le Can a da Do not r e m o v e or c o v er t h is la b el . N ot f or us e w it h s o l id f u el . N o t for us e w it h a ir f il t e rs Ne do it pa s e tr e u ti lis e a ve c u n comb usti b le s o lide. Al s o f o r us e in m o bil e ( m anu fact ured ) h om es aft er ho m e i s sit ed .
2 4 M A I NT E NAN CE 3 1 2 4 5 6 7 8 9 1 1 12 13 15 14 16 17 18 1 9 2 0 2 1 22 23 24 25 30 29 27 26 28 3 1 33 32 34 35 36 37 38 3 9 4 0 4 1 42 43 44 1) 1-8 9 -0 9 10 0 Bod y w e l d m en t 2) 1-1 0 -.
2 5 M A I NT E NAN CE Bu rner Pa rt s 1 3 2 4 6 5 7 8 9 10 1 1 14 15 16 13 12 17 1) 3- 4 0- 08 7 1 5 LP pi l ot 2) 2- 0 0- 73 1 2 2 Ig ni ter mo un t 3) 3- 4 0- 08 2 2 0 Ig ni ter (p i e zo ) 4) 3- 3 .
2 6 TR OUB LE S HOO TI N G Onl y Fo r Qua li fied In stal lers Lo ok thr o u gh h o l e in e n d o f l og to see i f a sp ar k j u mp s fr o m the i g n i tor e lec tr od e to th e p i l ot wh e n th e i gni tor b u tto n i s p u sh ed. Ch e ck i gni tor wi r e a n d c onn ec tion s fr o m p i ezo i gn i to r to igni to r c e r ami c a t pi lot.
2 7 TR OUB LE S HOO TI N G Onl y Fo r Qua li fied In stal lers G ood G ood Ch e ck M i l ivo l t outp u t o f th e r moc o u p l e . Sh o u l d b e 10 or m or e MV . C heck inlet p res s ure B a d Ad j u s t pi lot a d j u stm ent to ac hi ev e p r o p e r fl a m e .
2 8 TR OUB LE S HOO TI N G Onl y Fo r Qua li fied In stal lers M a in B urner wil l not l igh t (w it h valve in " o n " p os it io n) Is P ilot lit n o Lig ht p ilo t Y e s Ch e ck T h e r mopi l e vo l ta ge a t te r mi n al s mar ked T P o n va l ve .
2 9 TR OUB LE S HOO TI N G Onl y Fo r Qua li fied In stal lers A BL OW ER K IT , P A R T NUMBE R 1-0 0-0 91 0 2, MAN UF AC TUR ED BY H ARM AN ST O VE C O M P ANY , MA Y B E USE D W ITH T H I S C O NQU.
HA RM AN GO LD W AR RA NTY 6 YE AR TR ANS F ERA BL E LI M I T ED W AR RA NTY (Res idential) 1 YEAR LI MIT ED W AR RANT Y ( C o mmerc ial) 3 0 Ha rm a n G o ld W a r ran ty H arm a n Stove Com pan y w .
An important point after buying a device Harman Stove Company Conquest Gas Stove (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Harman Stove Company Conquest Gas Stove yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Harman Stove Company Conquest Gas Stove - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Harman Stove Company Conquest Gas Stove you will learn all the available features of the product, as well as information on its operation. The information that you get Harman Stove Company Conquest Gas Stove will certainly help you make a decision on the purchase.
If you already are a holder of Harman Stove Company Conquest Gas Stove, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Harman Stove Company Conquest Gas Stove.
However, one of the most important roles played by the user manual is to help in solving problems with Harman Stove Company Conquest Gas Stove. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Harman Stove Company Conquest Gas Stove along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center