Model 3733

Read this material before using this product.
Failure to do so can result in serious injury. Save this manual.
Copyright© 2002, 2009 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein.
For technical questions or replacement parts, please call 1-800-444-3353. Revised Manual 09l

Keep this manual for the safety warn ings and precautions, assembly, operat ing, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference.
Warnings
Important SAFETY
In this manual, on the labeling, and all other information provided with this product:
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
Work area safety 1.
Keep work area clean and well lit. a.
Cluttered or dark areas invite acci dents.
Do not operate power tools in b.
explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes.
Keep children and bystanders c.
away while operating a power tool. Distractions can cause you to lose control.
Electrical safety 2.
Power tool plugs must match the a.
outlet. Never modify the plug in any way. Do not use any adapter

plugs with grounded power tools. Unmodified plugs and matching out lets will reduce risk of electric shock.
tion. Safety equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries.
Avoid body contact with grounded b.
surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is grounded.
Keep guards in place and in good c.
working order.
Prevent unintentional starting. d.
Do not expose power tools to rain c.
Ensure the switch is in the off-po sition before connecting to power source and/or battery pack, pick ing up or carrying the tool. Carry ing power tools with your finger on the switch or energizing power tools that have the switch on invites acci dents.
or wet conditions. Water entering a power tool will increase the risk of electric shock.
Do not abuse the cord. Never use d.
the cord for carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock.
Remove any adjusting key or e.
wrench before turning the power tool on. A wrench or a key left at tached to a rotating part of the power tool may result in personal injury.
When operating a power tool out e.
doors, use an extension cord suit able for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
Do not overreach. Keep proper f.
footing and balance at all times. This enables better control of the power tool in unexpected situations.
If operating a power tool in a damp f.
location is unavoidable, use a Ground Fault Circuit Interrupter (GFCI) protected supply. Use of a GFCI reduces the risk of electric shock.
Dress properly. Do not wear loose g.
clothing or jewelry. Keep your hair, clothing and gloves away from moving parts. Loose clothes, jewelry or long hair can be caught in moving parts.
Personal safety 3.
If devices are provided for the con h.
Stay alert, watch what you are do a.
nection of dust extraction and col lection facilities, ensure these are connected and properly used. Use of these devices can reduce dust- related hazards.
ing and use common sense when operating a power tool. Do not use a power tool while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating power tools may result in serious personal injury.
Power tool use and care 4.
Do not force the power tool. Use a.
the correct power tool for your ap plication. The correct power tool will
Use safety equipment. Always b.
wear ANSI-approved eye protec

do the job better and safer at the rate for which it was designed.
ent from those intended could result in a hazardous situation.
Do not use the power tool if the b.
Service 5.
switch does not turn it on and off. Any power tool that cannot be con trolled with the switch is dangerous and must be repaired.
Have your power tool serviced by a.
a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.
Disconnect the plug from the c.
power source and/or the battery pack from the power tool before making any adjustments, chang ing accessories, or storing power tools. Such preventive safety mea sures reduce the risk of starting the power tool accidentally.
This tool vibrates during use. Re peated or long-term exposure to vibration may cause temporary or permanent physical injury, particularly to the hands, arms and shoulders. To reduce the risk of vibration-related injury:
Store idle power tools out of the d.
reach of children and do not allow persons unfamiliar with the power tool or these instructions to oper ate the power tool. Power tools are dangerous in the hands of untrained users.
Anyone using vibrating tools regu 1. larly or for an extended period should first be examined by a doctor and then have regular medical check- ups to ensure medical problems are not being caused or worsened from use. Pregnant women or people who have impaired blood circulation to the hand, past hand injuries, ner vous system disorders, diabetes, or Raynaud’s Disease should not use this tool. If you feel any medical or physical symptoms related to vibra tion (such as tingling, numbness, and white or blue fingers), seek medical advice as soon as possible.
Maintain power tools. Check for e.
misalignment or binding of moving parts, breakage of parts and any other condition that may affect the power tool’s operation. If dam aged, have the power tool repaired before use. Many accidents are caused by poorly maintained power tools.
Keep cutting tools sharp and f.
clean. Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control.
Do not smoke during use. Nico 2. tine reduces the blood supply to the hands and fingers, increasing the risk of vibration-related injury.
Use the power tool, accessories g.
and tool bits etc. in accordance with these instructions, taking into account the working conditions and the work to be performed. Use of the power tool for operations differ
Wear suitable gloves to reduce the 3. vibration effects on the user.

Use tools with the lowest vibration 4. when there is a choice between dif ferent processes.
touch the Saw Blade or any other part of the Saw, in all angles and depths of cut.
Include vibration-free periods each 5. day of work.
Do not handle the Power Switch (4) 6. with wet hands.
Grip tool as lightly as possible (while 6. still keeping safe control of it). Let the tool do the work.
Make sure the Tile Saw is located 7. on a flat, level, sturdy surface ca pable of supporting the weight of the Saw and work pieces.
To reduce vibration, maintain the tool 7. as explained in this manual. If any abnormal vibration occurs, stop use immediately.
Always use Diamond Saw Blades 8. (67113 4” Continuous Rim Dia mond Blade not included, sold separately) with a 4” diameter, 5/8” round arbor hole, and rated at 4480 RPM or greater.
Maintain labels and nameplates on 1. the Tile Saw. These carry important information. If unreadable or miss ing, contact Harbor Freight Tools for a replacement.
Use the Tile Saw only for cutting 9. dry or wet ceramic tile, quarry tile, marble, terra-cotta, and slate with a maximum thickness 1-1/16”.
Use the right product for the right 2. job. There are certain applications for which this product was designed. Do not use small equipment, tools, or attachments to do the work of larger industrial equipment, tools, or attach ments. Do not use this product for a purpose for which it was not intended.
Do not use the Tile Saw for cutting 10. metals or for cutting curves. This may cause the Saw Blade to break and/or reduce its service life.
Make sure the Saw Blade is wet at 11. all times when cutting.
To reduce the risk of electrocution, 12. keep all connections dry and off the ground. Do not touch plug with wet hands. Ground Fault Circuit In terrupter (GFCI) protection should be provided on the circuit(s) or outlet(s) to be used for the tile saw (GFCI is not included in this machinery). Re ceptacles are available having built-in GFCI protection and may be used for this measure of safety.
This product must continuously 3. run with cold water. Dry running will cause serious damage to the Pump seals.
Check Blade Guard for proper for 5. ward/backward movement before each use. Do not operate the Tile Saw if the Blade Guard does not move freely. Make sure the Blade Guard moves freely and does not

Never leave the Tile Saw unattend 18. ed when it is plugged into an elec trical outlet. Turn off the Tile Saw, and unplug it from its electrical outlet.

CORD
TILE SAW
Always keep the water level at the 19. recommended level. Fill the tray in the Body (19) until it is about 3/4 completely submerged, but do not overfill.
OUTLET
DRIP LOOP
Avoid splashing water on the 20. Motor (32), Power Switch, Power Cord/Plug, or any other electrical component. Make sure to stand on a dry, insulated surface such as a rubber mat while using the Tile Saw.
13. Always arrange a “drip loop” in the Power Cord (11) connecting the Tile Saw to a 120 volt, grounded, electrical outlet. A drip loop is that part of the Power Cord below the level of the outlet, or the connector if an extension cord is used, to pre vent water traveling along the Power Cord and coming in contact with the outlet. If the Power Plug or electrical outlet does get wet, do not unplug the Power Cord. Disconnect the fuse or circuit breaker that supplies power to the tool. Then, unplug and examine for presence of water in the outlet. See Figure 1, above.
To avoid accidental injury, always 21. wear heavy duty work gloves when changing the Saw Blade. Before using the Tile Saw, make sure the Saw Blade is properly and securely mounted on the Saw Spindle. Make sure the Saw Blade is balanced, and is not cracked or bent.
The Saw Blade will become hot 22. while cutting. Allow the Saw Blade to completely cool before handling.
Allow the Saw Blade to spin up to 23. full speed before feeding a work piece into it. When turning off the Tile Saw, allow the Saw Blade to spin down and stop on its own. Do not press against the Saw Blade to stop it.
Use cold water only. 14. Never use hot water. Using hot water can damage the Pump seals.
Never run the Tile Saw without a 15. water supply. Running the unit with out a water supply will cause irrepa rable damage to the Pump.
Do not force the Saw Blade into 24. the work piece when cutting. Apply moderate pressure, allowing the Saw Blade to cut without being forced.
Make sure the water supply used 16. for the Tile Saw is not dirty, sandy, and does not contain any corro sive chemical products.
Turn off the Tile Saw and allow the 25. Saw Blade to stop on its own if the Saw Blade is to be backed out of an uncompleted cut.
Make sure to change the water 17. when necessary while in use and rinse out the Tub after every use.

Never attempt to remove material 26. stuck in the moving parts of the Tile Saw while it is plugged in and running.
Failure to do so may result in the tile binding against the Saw Blade.
Make sure the Table and surround 35. ing area are clear with the excep tion of the tile to be cut.
When cutting a large work piece 27. make sure its entire length is prop erly supported. If necessary, use a roller stand (not included) with larger work pieces.
Always turn off the Tile Saw and 36. unplug it from its electrical outlet before changing accessories or performing any inspection, mainte nance, or cleaning procedures.
Never lean on the Tile Saw. 28. Seri ous injury could result if the Tile Saw is tipped or if the rotating Saw Blade is accidently contacted.
WARNING! 37. Some dust created by power sanding, sawing, grind ing, drilling, and other construction activities, contain chemicals known (to the State of California) to cause cancer, birth defects or other repro ductive harm. Some examples of these chemicals are: lead from lead- based paints, crystalline silica from bricks and cement and other masonry products, arsenic and chromium from chemically treated lumber. Your risk from these exposures varies, depend ing on how often you do this type of work. To reduce your exposure to these chemicals: work in well venti lated areas, and work with approved safety equipment such as those dust masks that are specially designed to filter out microscopic particles. (California Health & Safety Code § 25249.5, et seq.)
Industrial applications must follow 29. OSHA requirements.
For your safety: In extreme work 30. ing conditions, sensors in the Tile Saw will automatically switch off the Motor to prevent overheating. In this event, turn the Power Switch to its “OFF” position. Wait five min utes or until the Motor has cooled. Making sure your hands are dry, de press the Circuit Breaker. Then, turn the Power Switch to its “ON” position to resume cutting.
Never attempt to cut more than 31. one tile at a time.
Never attempt to cut freehand. 32. Make sure the tile to be cut is pressed firmly against the Rip Fence (7).
Never cut pieces too small to be 33. held securely against the Cutting Guide without leaving enough space for the hand to be a safe distance from the Saw Blade.
Make sure the tile to be cut off has 34. sufficient room to move sideways.

situations that may occur. It must be understood by the operator that common sense and caution are fac tors which cannot be built into this product, but must be supplied by the operator.
OFF first. If the blade stalls, turn the power switch to the OFF position im mediately to prevent damage to the motor.
Do not use accessories which 6. are not specifically designed and recommended by the tool manu facturer. Just because the accessory can be attached to your power tool, it does not assure safe operation.
Safety Warnings
This power tool is intended to 1. function as a cut-off tool. Read all safety warnings, instructions, illus trations and specifications pro vided with this power tool. Failure to follow all instructions listed below may result in electric shock, fire and/ or serious injury.
The rated speed of the accessory 7. must be at least equal to the maxi mum speed marked on the power tool. Accessories running faster than their RATED SPEED can break and fly apart.
The outside diameter and the 8. thickness of your accessory must be within the capacity rating of your power tool. Incorrectly sized accessories cannot be adequately guarded or controlled.
DO NOT EXPOSE TO RAIN OR USE 2. IN DAMP LOCATIONS.
Specific Cautions: 3.
Wear ANSI-Approved eye protection. a.
Use splash hood for every operation b.
Wear personal protective equip 9. ment. Depending on application, use face shield, safety goggles or safety glasses. As appropriate, wear dust mask, hearing protec tors, gloves and workshop apron capable of stopping small abra sive or workpiece fragments. The eye protection must be capable of stopping flying debris generated by various operations such as safely goggles or glasses. The dust mask or respirator must be capable of filtrating particles generated by your opera tion. Prolonged exposure to high in tensity noise may cause hearing loss.
for which it can be used.
Disconnect saw before servicing, c.
when changing cutting wheel and cleaning.
Use only with smooth-edge cut d.
ting wheels, free of openings and grooves.
Replace damaged cutting wheel e.
before operating.
Operations such as grinding, 4. sanding, wire brushing, polishing are not recommended to be per formed with this power tool. Opera tions for which the power tool was not designed may create a hazard and cause personal injury.
Keep bystanders a safe distance 10. away from work area. Anyone entering the work area must wear personal protective equipment.
Do not attempt to free a stalled 5. blade without turning the Tile Saw

Fragments of workpiece or of a broken accessory may fly away and cause injury beyond immediate area of operation.
Position the cord clear of the spin 11. ning blade. If you lose control, the cord may be cut or snagged and your hand or arm may be pulled into the spinning accessory. Avoid uninten tional starting. Prepare to begin work before turning on the tool.
Do not leave the tool unattended 12. when it is plugged into an electri cal outlet. Turn off the tool, and un plug it from its electrical outlet before leaving.
This product is not a toy. 13. Keep it out of reach of children.
The warnings, precautions, and 17. instructions discussed in this in struction manual cannot cover all possible conditions and situations that may occur. It must be under stood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
instructions.
Some dust created by power sand 15. ing, sawing, grinding, drilling, and other construction activities, contains chemicals known [to the State of California] to cause can cer, birth defects or other repro ductive harm. Some examples of

low resistance path to carry electricity away from the user, reducing the risk of electric shock. (See 3-Prong Plug and Outlet.)
To prevent electric shock and death from incorrect grounding wire connection: Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.
The grounding prong in the plug 3. is connected through the green wire inside the cord to the ground ing system in the tool. The green wire in the cord must be the only wire connected to the tool’s grounding system and must never be attached to an electrically “live” terminal. (See 3-Prong Plug and Outlet.)
The tool must be plugged into 4. an appropriate outlet, properly installed and grounded in accor dance with all codes and ordinanc es. The plug and outlet should look like those in the preceding illustration. (See 3-Prong Plug and Outlet.)
Grounded Tools: Tools with Three
with Two Prong Plugs
Prong Plugs
Tools marked with “Grounding 2. Required” have a three wire cord and three prong grounding plug. The plug must be connected to a properly grounded outlet. If the tool should electrically malfunction or break down, grounding provides a

Double insulated tools may be used 2. in either of the 120 volt outlets shown in the preceding illustration. (See Outlets for 2-Prong Plug.)
extension cord or have it repaired by a qualified electrician before using it.
Protect the extension cords from 7. sharp objects, excessive heat, and damp or wet areas.

Grounded 1. tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.
As the distance from the supply outlet 2. increases, you must use a heavier gauge extension cord. Using exten sion cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and pos sible tool damage. (See Table A.) The smaller the gauge number of the wire, the greater the capacity of the cord. For ex ample, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Table A.)
When using more than one exten 3. sion cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See Table A.)

If you are using one extension cord 4. for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Table A.)
If you are using an extension cord 5. outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.
Make sure the extension cord is prop 6. erly wired and in good electrical con dition. Always replace a damaged

and is easy to clean. Its efficient design returns water directly to the reservoir and is accurate enough for most ceramic tile, quarry tile, marble, terra cotta, and slate jobs.
To Install The 4” Diamond Tile Saw
Blade:
When unpacking, check to make sure that the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible.
Remove the Screw (16) that holds 2. the Table (1) in place and left the Table until the three catches at its midsection clear the Table’s under side. Then remove table complete lyh. (See Figure 2, next page.)
putting into use
Remove the Nut (37) attached to the 3. Motor (32) arbor. Then remove the Outer Flange (36). See Figure 3, next page.)
Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product.
To prevent serious injury from accidental operation: Turn the Power Switch of the tool to its “OFF” position and unplug the tool from its electrical outlet before assembling or making any adjustments to the tool.
Attach Outer Flange and secure Nut 5. over arbor. Turn Nut clockwise until tight. Do not overtighten. (See Fig ure 3.)
Disconnect Guard Stand (24) from 6. Guard Assembly. Slide Stand’s unthreaded end through slot under
water supply that keeps its Tile Saw Blade cool, reduces dust and debris,

Angle Gauge (21) Body (19)
4” Blade (Not Included)


Arrow Points To FRONT of Tile Saw
Remove Screw (16) to Remove Table (1)
4” Blade (Not Included)

Table (adjacent to Blade slot) and tighten.
correct tool will do the job better and safer at rate for which it is designed.
Reinstall the Table and secure it in 7. place with the Screw (16).
Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product.
To prevent serious injury from accidental operation: Turn the Power Switch of the tool to its “OFF” position and unplug the tool from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.
Designate a work area that is clean 1. and well lit. The work area must not allow access by children or pets to prevent injury and distraction.

Route the power cord along a safe 2. route to reach the work area with out creating a tripping hazard or exposing the power cord to pos sible damage. The power cord must reach the work area with enough extra length to allow free movement while working.
Reinstall Table and secure it in place 4. with the Screw (16).
Adjust the Rip Fence (7) to the width 5. of cut desired. To do so, lift up on each Lever (9) located at each end of the Rip Fence. Slide the Rip Fence to the right or left until the desired width of cut is obtained. Then, lock the Rip Fence in place by pressing down on each Lever. CAUTION! Keep fingers clear of Levers.
Secure loose work pieces using 3. clamps (not included) to prevent movement while working.
Plug the Power Cord (11) into a 6. grounded, 120 Volt electrical outlet.
To Make Straight Cuts:
Turn the Power Switch (4) to its “ON” 7. position, and allow the Blade to spin up to full speed.
Remove the Screw. Then remove 1. the Table from the Tile Saw unit.
Fill the Body (19) with water. Be sure 2. to use cold, clean water.
Once the proper water level is ac 9. quired, plug the Power Cord into its electrical outlet and turn the Power Switch to its “ON” position.
Fill With Water As Indicated By Arrow
Place the workpiece to be cut against 10. the Rip Fence (7), and then slowly feed the workpiece into the spinning Blade.

When finished making the cut, turn 11. the Power Switch (4) to its “OFF” position and unplug the Power Cord (11) from its electrical outlet.
To Make Beveled Cuts:
Remove the Screw. Then, remove 1. the Table from the Tile Saw unit.

Fill the Body with water. 2. CAUTION: Make sure the water level is high enough to cover the lower edge of the Blade but not above the maxi mum water level as indicated by the arrow.
position and unplug the Power Cord from its electrical outlet.
To Make Mitered Cuts:
To make a mitered cut, place the An 1. gle Gauge (21) against the Rip Fence (7). Then position the workpiece against the Angle Gauge, and slowly feed the workpiece into the Blade.
When finished making the angled cut, 2. turn the Power Switch to its “OFF” position and unplug the Power Cord from its electrical outlet

Servicing
Procedures not specifically explained in this manual must be performed only by a qualified technician.
To prevent serious injury from accidental operation: Turn the Power Switch of the tool to its “OFF” position and unplug the tool from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.

To prevent serious injury from tool failure: Do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use.
Place the workpiece to be cut against 4. the Rip Fence (7), and slowly feed the workpiece into the Blade.
When finished making the beveled 5. cut, turn the Power Switch to its OFF”

section of this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury.
Lubrication
BEFORE EACH USE, 1. inspect the general condition of the tool. Check for loose screws, misalignment or binding of moving parts, cracked or broken parts, damaged electrical wiring, loose or worn out blade, and any other condition that may affect its safe operation.
To clean: 6. Wipe with a damp cloth, vacuum or use compressed air. Do not use solvents.
After Use, 2. clean external surfaces of the tool with clean cloth. Drain wa ter from the water tray and wash out any residue from the recessed pump sump area.
When storing: 7. Store Tile Saw in a safe, clean, dry, location out of reach of children.
Tool service must be performed 3. only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury.
When servicing a tool, use only 4. identical replacement parts. Fol low instructions in the “Inspec tion, Maintenance, And Cleaning”
Problem Possible Causes Likely Solutions
Tool will not start No power at outlet. 1. Cord not connected. 2. Check power at outlet. 1. Check that cord is plugged in. 2.
Blade spins slowly Arbor shaft binding 1. Motor brushes worn 2. Check shaft for free spinning 1. Replace brushes 2. Excessive vibration Bent or off-balance blade 1. Bent Arbor Shaft 2. Replace blade with new one 1. Check shaft for run-out 2. Running hot; excess smoke
Water flow problem. 1. Not enough water 2. Running with hot/warm water 3.
Check connection 1. Add proper amount of water 2. Always run with cold water 3.
Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.


3 Handle Base 2 23 Motor Holder (Top) 1
5 Wire 4 25 Screw (M4 x 7 x 16 mm) 2
6 Screw (M3 x 15) 4 26 Motor Holder (Bottom) 1
11 Power Cord 30 Screw (M4 x 16) 2
12 Screw (M4 x 16) 1 31 Ruler 1
16 Screw (M4 x 20) 1 35 Inner Flange 1
17 Wrench (6 x 13 mm) 6 36 Outer Flange 1
18 Washer 1 37 Nut (M8 x 1.25) 1
19 Body 4 38 Screw (M4 x 16) 4
20 Plastic Stand 4 39 Bolt (M6 x 20) 1
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.


Record Product’s Serial Number Here:
replacement parts.

Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this prod uct is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. This warranty is express ly in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness.
To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the com plaint must accompany the merchandise. If our inspection verifies the defect, we will ei ther repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return re paired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Tool will not start | 1. No power at outlet. 2. Cord not connected. | 1. Check power at outlet. 2. Check that cord is plugged in. | p.17 |
| Blade spins slowly | 1. Arbor shaft binding 2. Motor brushes worn | 1. Check shaft for free spinning 2. Replace brushes | p.17 |
| Excessive vibration | 1. Bent or off-balance blade 2. Bent Arbor Shaft | 1. Replace blade with new one 2. Check shaft for run-out | p.17 |
| Running hot; excess smoke | 1. Water flow problem. 2. Not enough water 3. Running with hot/warm water | 1. Check connection 2. Add proper amount of water 3. Always run with cold water | p.17 |
| Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service. | p.17 |