For Your Own Safety Read Instruction Manual Before Operating This Equipment Indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
G6045/G6046/G6047 18 Gauge Brad Nailer -2 - 10. USE PROPER EXTENSION CORD for the tool. Make sure your extension cord is in good condition. Conductor size should be in accordance with the chart below. The amperage rating should be listed on the motor or tool nameplate.
G6045/G6046/G6047 18 Gauge Brad Nailer -3 - Operating this nailer can propel objects into the air, causing immedi- ate eye damage. To protect yourself, always wear American National Standards Institute (ANSI) approved safety glasses or goggles when oper- ating this equipment.
G6045/G6046/G6047 18 Gauge Brad Nailer -4 - INTRODUCTION Commentary Most importantly, we stand behind our tools. If you have any service questions or parts requests, please call or write us at the location listed below.
G6045/G6046/G6047 18 Gauge Brad Nailer -5 - Compressed Air System Safety Yoke Mechanism The safety yoke is a mechanical device that can fail. Never rely on the safety yoke mechanism as an excuse to point the nailer at yourself or any bystanders. Serious injury may occur.
G6045/G6046/G6047 18 Gauge Brad Nailer -6 - OPERATION Loading Nailer Operating Nailer To load your nailer: 1. Disconnect the air supply from the nailer! 2. Flip the magazine latch in the direc- tion shown in Figure 1 . If you have not read the safety instruc- tions in this manual, do not operate the nailer.
G6045/G6046/G6047 18 Gauge Brad Nailer -7 - Cleaning Nailer Oiling Nailer Special oil has been included with your new Grizzly nailer to help maintain its use- ful life. Place one drop of oil in the nailer air inlet (as shown in Figure 4 ) before every use.
Always disconnect air from nailer whenever clearing a jammed nail! G6045/G6046/G6047 18 Gauge Brad Nailer -8 - To clear a jammed nail from the discharge area on the Model G6046: 1. Disconnect the nailer from the air supply! Remove all brad nails from the magazine.
G6045/G6046/G6047 18 Gauge Brad Nailer -9 - Replacing Pistons/O-Rings If you use your nailer day in and day out, Grizzly offers repair pistons as cheap insurance against wasted down time and lost profits in the event that a piston or pis- ton shaft becomes worn out.
G6045/G6046/G6047 18 Gauge Brad Nailer -10 - G6045 PART BREAKDOWN 1 2 3 4 5 7 6 8 9 10 11 12 75 71 72 74 13 14A 18 19A 21 22 19 20 23 24 25 27 26 32 60 62 58 61 63 59 65 64 68 66 67 34 39 35 36 37 38 .
G6045/G6046/G6047 18 Gauge Brad Nailer -11 - 01 P6045001 CAP SCREW 02 P6045002 LOCK WASHER 03 P6045003 CAP 04 P6045004 SEAL 05 P6045005 SPRING 06 P6045006 O-RING 07 P6045007 CAP SEAL 08 P6045008 PISTO.
G6045/G6046/G6047 18 Gauge Brad Nailer -12 - G6046 PART BREAKDOWN 1 2 3 4 5 7 6 8 9 10 11 12 75 71 72 74 13 14A 18 19A 21 22 19 20 23 24 25 27 26 32 60 62 58 61 63 59 65 64 68 66 67 34 39 35 36 37 38 .
G6045/G6046/G6047 18 Gauge Brad Nailer -13 - 01 P6046001 CAP SCREW 02 P6046002 LOCK WASHER 03 P6046003 CAP 04 P6046004 SEAL 05 P6046005 SPRING 06 P6046006 O-RING 07 P6046007 CAP SEAL 08 P6046008 PISTO.
G6045/G6046/G6047 18 Gauge Brad Nailer -14 - G6047 PART BREAKDOWN 1 2 3 4 5 7 6 8 9 10 11 12 75 71 72 74 13 14A 18 19A 21 22 19 20 23 24 25 27 26 32 60 62 58 61 63 59 65 64 68 66 67 34 39 35 36 37 38 .
G6045/G6046/G6047 18 Gauge Brad Nailer -15 - 01 P6047001 CAP SCREW 02 P6047002 LOCK WASHER 03 P6047003 CAP 04 P6047004 SEAL 05 P6047005 SPRING 06 P6047006 O-RING 07 P6047007 CAP SEAL 08 P6047008 PISTO.
TROUBLESHOOTING Air leaking at trigger valve area. Air leaking between hous- ing and hose. Air leaking between hous- ing and cap assembly. Tool skips nails while dis- charging. Tool runs slowly or has a loss of power. Fasteners frequently jam the nailer.
G6045/G6046/G6047 18 Gauge Brad Nailer -17 - Grizzly Industrial, Inc. warrants every product it sells for a period of 1 year to the original purchaser from the date of purchase. This warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence, accidents, repairs or alterations or lack of main- tenance.
Name __________________________________________________________ Street __________________________________________________________ City ____________________ State ________ Zip _________ Phone Number __.
FOLD ALONG DOTTED LINE GRIZZLY INDUSTRIAL, INC. P.O. BOX 2069 BELLINGHAM, WA 98227-2069 TAPE ALONG EDGES--PLEASE DO NOT STAPLE Name________________________________ Street______________________________.
An important point after buying a device Grizzly G6045 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Grizzly G6045 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Grizzly G6045 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Grizzly G6045 you will learn all the available features of the product, as well as information on its operation. The information that you get Grizzly G6045 will certainly help you make a decision on the purchase.
If you already are a holder of Grizzly G6045, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Grizzly G6045.
However, one of the most important roles played by the user manual is to help in solving problems with Grizzly G6045. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Grizzly G6045 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center