Page 4 of the Grindmaster HC-2 user manual — HC-2 Hot Chocolate Dispenser Specifications
Page 4 · click to enlarge
Page 4

Introduction

We are pleased you have chosen Crathco’s Whipped Hot Chocolate Dispenser for your hot chocolate service. You have chosen the finest engineered, most functionally sound and easy to operate piece of equipment available. The HC-2 is a manual push and hold dispense machine, producing 1 ounce of chocolate per second into any cup size. It will accommodate bag-in-boxes, cans or hoppers of chocolate syrup.

Inside the carton you should find:

1. HC-2 Whipped Hot Chocolate Machine 2) Plastic chocolate hopper (optional) 3) Drip tray 4) Operation and Instruction Manual

The HC-2 Whipped Hot Chocolate Dispenser is supplied complete with a 6 foot, 120V A.C. 3 wire cord and NEMA 5-20 plug. Plugging the unit into a NEMA 5-20R outlet (20 AMP receptacle) is the only electrical service required. Plumbing service requires a high temperature food grade water supply line. The water supply line is connected to a 1/4” male flare fitting in the rear of the unit. Installation should comply with the National Plumbing Code.

HC-2 Hot Chocolate Dispenser Specifications

Model HC-2 Finished Product SizeVariable due to manual push and hold button Dispenser Rate1 ounce per second Drink Strength RatioVariable between 4:1 and 6:1 - factory set at 5:1 Hot Chocolate Dispenser Temperature180 degrees F + 5 degrees F Production Capacity 120 degrees F water in 50 degrees F water in(230) 5 oz. cups/hour (115) 5 oz. cups/hour Power Requirement1800 watts, 15 Amps Electrical Service Plumbing Service120 Volt a.c., 20 Amp. NEMA 5-20 outlet 0.75 GPM minimum, 30-75 PSI water supply line to 1/4” male flare fitting Water Compartment2 3/4 gallons Initial Fill TimeApproximately 5 minutes Dispenser Spout Clearance6” Overall Height27” Body Width10 1/2” Body Depth17 1/2” Product Compartment10” H x 9” W x 10” D
Page 5 of the Grindmaster HC-2 user manual — How to Dispense a Cup of Hot Chocolate
Page 5 · click to enlarge
Page 5

Installation and Start-Up Procedures

Remove all packing material around the chocolate dispenser.

Place the hot chocolate dispenser upright on a leveled table at location intended for operation.

Place the drip tray on the front of the dispenser; using the 2 locating tabs on the sides of the tray.

Water Inlet Connection:

An experienced plumber or equipment installer should connect the dispenser to a properly sized water line. Water supply should be 0.75 GPM minimum, 30-75 PSI.

Installation should comply with the National Plumbing Code.

The water supply line connects to the male flare found on the rear of the unit, using a 1/4” female flare nut.

Copper or brass tubing or stainless steel braided teflon lined or similar high temperature food grade hose should be used for the water line. Include extra length of water supply line to allow room to move the unit for cleaning.

Hot or cold water hookup can be used. Hot water will increase the production of the dispenser.

Be sure to flush the supply line before making the connection to dispenser.

A shut-off valve and union should be in the supply line near the dispenser.

Start-Up Procedures:

Plug the hot chocolate dispenser into a 120V 20 AMP, NEMA 15-20 outlet. A 6 foot, 3 wire cord with NEMA 5-20 plug is required.

Fill the hot chocolate dispenser with water. With power and water supplies to the dispenser turned “On”, the dispenser will automatically fill with water. The water tank holds 2 3/4 gallons. It takes approximately 5 minutes to initially fill the water tank because of the auto refill system employed with this dispenser. When the water tank is full of water, filling will stop and the water level will be maintained at this point.

The water in the tank will automatically heat up to dispensing temperature. A 30-40 minute initial heat-up time is required when the dispenser is connected to 50 degree F water. If a hot water hookup is used, heat-up time will be shorter.

How to Dispense a Cup of Hot Chocolate

Make sure the dispenser is filled with water and up to temperature.

Load a hot chocolate bag-in-box or fill hopper with chocolate syrup.

Page 6 of the Grindmaster HC-2 user manual — FIGURE E
Page 6 · click to enlarge
Page 6
Grindmaster HC-2 — How to Dispense a Cup of Hot Chocolate (cont.) diagram (page 6)
Fig. 1 · How to Dispense a Cup of Hot Chocolate (cont.)

How to Dispense a Cup of Hot Chocolate (cont.)

1 Bag-in-Box Loading Instructions

a.

Lift the tab located on top of the box.

b.

Pull out the tube assembly with the retainer ring.

FIGURE A

Secure the retainer ring on the leading edge of the cutout. (Refer to Figure A)

d.

Insert the product box on the product shelf with the top side down and with the hose assembly toward the front.

e.

Remove the stopper cap from the box tube assembly. (Refer to Figure B)

FIGURE B

f.

Connect the box tube assembly over the pump inlet tube.

g.

Remove the pinch clamp from the box tube assembly. (Refer to Figure C)

h.

You are now ready to draw product.

Push and hold the dispense switch.

FIGURE C

PUSH BUTTON SYRUP SWITCH

PUSH BUTTON WATER SWITCH

The dispenser is now ready for operation.

Adjustments

DISPENSE SWITCH

PRESS & HOLD TO DISPENSE CHOCOLATE

Mix Ratio Adjustment:

FIGURE D

The drink strength is adjustable from 4 parts water to 1 part chocolate to 6 parts water to 1 part chocolate. The dispenser is factory set at 5 parts water to 1 part chocolate.

MORE WATER WEAKER CHOCOLATE

LESS WATER STRONGER CHOCOLATE

SLOT

Remove the hole plug.

Insert a screwdriver in the slot and turn clockwise for less water/stronger chocolate or counter clockwise for more water/weaker chocolate. (Refer to Figure E)

FIGURE E

Front Elevation

Page 7 of the Grindmaster HC-2 user manual — THERMOSTAT LABEL
Page 7 · click to enlarge
Page 7

Thermostat Adjustment:

!

Grindmaster HC-2 — ! diagram (page 7)
Fig. 2

Access to temperature adjustment is from the top.

CALIBRATION SET SCREW CW=LOWER TEMPERATURE CCW=HIGHER TEMPERATURE

To remove the top cover, remove the 2 screws and lift the cover off. Water temperature is factory set at 180 degrees F + 5 degrees F.

SLEEVE (FULL CW=ON)

Insert a screwdriver in the slot and turn clockwise to obtain a lower temperature and counterclockwise for a higher temperature (Refer to Figure F).

THERMOSTAT LABEL

THERMOSTAT BRACKET

TOP VIEW TOP COVER REMOVED

Cleaning

FIGURE F

Daily Cleaning Mixing Chamber:

The stainless steel cabinet is kept clean with a damp cloth or a stainless steel cleaner.

Push the whipper rinse switch to flush until the water leaving the dispense spout is clear.

Weekly Cleaning Mixer(Refer to Figure G)

Disconnect the hoses to the mixer.

Lift off the cover.

Lift off the funnel cover.

Turn the whipping chamber clockwise and pull it off.

Pull off the whipping blade. Leave the backing washer on the metal shaft.

Wash all parts in mild soap. Rinse well and reassemble.

Show 10 more labels / short text on this page
Product Switch Cover · Water Switch · Mixing Chamber · Syrup Inlet Tube · Pump · Water · Inlet Tube · inlet Tube · Whipping Chamber · Dispenser Switch
Page 8 of the Grindmaster HC-2 user manual — Cleaning (cont.)
Page 8 · click to enlarge
Page 8

Cleaning (cont.)

Weekly Cleaning Syrup System:

Close the clamp on the product box tube and disconnect from the pump inlet.

Connect the cleaning tube to the pump inlet and drop the open end of the tube into a basin of hot, soapy water.

Push the pump rinse switch until clear water leaves the spout.

Repeat steps 3 with hot, clean water until there is no trace of soap.

Remove the cleaning tube and reconnect the pump inlet to the box tube. Open the clamp on the box tube.

Page 9 of the Grindmaster HC-2 user manual — Troubleshooting Guide
Page 9 · click to enlarge
Page 9

Troubleshooting Guide

The following procedures must be performed by a qualified service technician.

Problem/Possible Cause Service Check Remedy Consistent filling of water tank • Leaking fill solenoid valve • Electrode lined up or faulty • Faulty white common connection to ground • Liquid level control faulty• Removing power to machine does not stop tank fill • Jumper from C to high on probe side of board shuts fill off • Jumper from COM on probe side of board to ground stops fill • Jumper from High to COM on probe side of liquid level does not shut fill Off• Clean-replace fill valve • Clean electrode rods. Check rods & wiring; replace if necessary • Tighten, clean, replace COM connection to ground • Replace liquid level control Water not heating up • Thermostat Off • Thermostat faulty • Power relay faulty • Heating element faulty• Visual • Thermostat contacts do not close with sleeve clockwise and inner screw counter clockwise • No voltage to heating element - 120V. across coil of relay does not pull in • 120V across heating element but no heat-element reads open with ohmeter• Turn thermostat sleeve clockwise • Replace thermostat • Replace power relay • Replace heating element Nothing dispensed - water or chocolate - No whipper action • Dispense switch faulty• Switch reads open with ohmeter when switch is pushed• Replace switch No water dispensed or whipper action - Only chocolate is dispensed • Water switch faulty• Switch reads open with ohmeter when switch is in On position• Replace switch No water dispensed - Whipper works and chocolate is dispensed • Tank refill problem • Kinked silicone tubing • Dispense valve faulty• Check auto refill system • Check tubing run to mixer assembly • 120V across input terminals on valveno actuation• Clean-replace components • Reroute tubing-unkink • Replace coil or entire valve No whipper action - only water and chocolate are dispensed • Whipper motor faulty• 120V across motor leads but motor does not run• Replace whipper motor No chocolate dispensed - Whipper works and some water is dispensed • No syrup to pump • Kinked pump tubing • Syrup pump faulty• Check syrup container • Check tubing runs • 120V across pump motor leads, pump does not run; check for jammed rollers• Replenish syrup supply • Unkink, reroute, replace • Replace syrup pump-Unjam rollers Constant dispense - chocolate, water and whipper action • Dispense switch faulty• Switch reads closed with ohmeter with switch in the Off position• Replace switch Constant water dispense or drip • Dispense valve faulty• Dispense or drip continues with power Off• Clean, rebuild; replace dispense valve
Page 10 of the Grindmaster HC-2 user manual — Troubleshooting Guide (cont.)
Page 10 · click to enlarge
Page 10

Troubleshooting Guide (cont.)

Problem/Possible Cause Service Check Remedy

Chocolate is dispensed or constantly dripping •

Syrup pump rollers not engaging silicone tubing Pump tubing faulty

Check for syrup pump rollers in “storage’ position or weak springs Check for holes in tubing or loose connections to break vacuum

Rotate pump to engage rollers or replace pump Replace pump tubing-check connections

If you still need help, call our Technical Service Department at (800) 568-5715 (USA or Canada) or 1-502-425-4776, Monday through Friday, 8 am - 6 pm EST, or an authorized service center in your area. Please have the model and serial numbers ready so that accurate information can be given.

Prior authorization must be obtained from Grindmaster Corporation’s Technical Services Department for all warranty claims.

Show 5 more labels / short text on this page
• · • · • · • · •
Page 11 of the Grindmaster HC-2 user manual — UTILITIES
Page 11 · click to enlarge
Page 11

Rough-In Drawings

Grindmaster HC-2 — Rough-In Drawings diagram (page 11)
Fig. 3 · Rough-In Drawings

1 3/16” 7 13/16” 17 1/2”

10 1/2”

3 3/4”

17 11/16” Drink Strength Adjustment (Behind Hole Plug) Syrup Connection

Water Inlet 1/4” SAE Male Flare Fitting

6 FT. 120 Vac Cord With NEMA

Product/Rinse Push Button Switches

Water Tank Drain Plug

REAR SIDE FRONT

Door removed for clarity

UTILITIES

Water Connection 1.) Hot or Cold Supply 2.) .75 GPM Minimum Flow At Unit 30 to 70 PSIG

Electric 1.) 120 AC, 20 Amp Service Required 2.) 1800 Watt Tank Heater, 15 Amp Total Load, Approx.

Show 7 more labels / short text on this page
14” · Product Shelf · 27” · 5-20 Plug · 6” · 5” 5” · Drawing # A090-757
Page 12 of the Grindmaster HC-2 user manual — FRONT CONTROL PANEL
Page 12 · click to enlarge
Page 12

Exploded View Whipper Assembly

Grindmaster HC-2 — Exploded View Whipper Assembly diagram (page 12)
Fig. 4 · Exploded View Whipper Assembly

FRONT CONTROL PANEL

ITEM NUMBERPART NUMBERQTYDESCRIPTION 1A533-0231Whipper Motor 26010512#8-32 Acorn Nut 3A539-1152#6-32 x 1/4” Truss Head Screw 4A548-0661Washer, Slinger 5A548-0631Base, Self-Locating Whipper 6A551-0581Bearing, 1/4 ID x 5/16 OD x 3/16 7A544-0341Seal, 0.250 x 0.616 x 3/16 8A544-0331O-Ring, 0.250 x 0.070 9A548-0651Blade, 4 Blade Whipper w/Stop 10A548-0671Whipper Cover 11A548-0781Whipper Funnel 12A548-0621Chamber, GM Whipper 13A548-0641Restrictor, Angle Outlet 146030082#6 Spring Lock Washer

Drawing # A720-036 Rev. B

Page 13 of the Grindmaster HC-2 user manual — A548-111
Page 13 · click to enlarge
Page 13

Exploded View Pump

Grindmaster HC-2 — Exploded View Pump diagram (page 13)
Fig. 5 · Exploded View Pump

A548-111

A548-112

A314-553 (MFG BY A.M.W.)

CLEAR TYGON TUBING P/N: A585-250 (SUPPLIED WITH PUMP)

Drawing # A0903-028 Rev. Rel

Page 14 of the Grindmaster HC-2 user manual — Wiring Diagram 120V With Portion Control (Option 5)
Page 14 · click to enlarge
Page 14

Wiring Diagram 120V With Portion Control (Option 5)

Grindmaster HC-2 — Wiring Diagram 120V With Portion Control (Option 5) diagram (page 14)
Fig. 6 · Wiring Diagram 120V With Portion Control (Option 5)

Black · Red White Black · Drawing # 091-329

Page 15 of the Grindmaster HC-2 user manual — DESCRIPTION
Page 15 · click to enlarge
Page 15

HC-2 Parts List

PART NO.

DESCRIPTION

515067 549-006 712-046 712-018 515027 535-058 537-025 537-009 537-033 537-022 720-024 550-089 537-109 531-009 537-016 537-030 515001 531-029 533-040 548-111 548-112 533-023 548-066 548-063 551-058 544-034 544-033 548-065 548-067 548-078 548-062 548-064 720-036 585-250 585-048 585-049 585-045 585-039 585-047 511005

515074 Power Cord Liquid Level Control Thermostat Electrode Assembly Power Relay 25/30 Amp 115V Coil Heater Water Fill Valve Fill Valve Repair Kit Coil for Fill Valve 0.5GPM Flow Disc for Fill Valve Heater Tank Fill Tube-Outlet from Fill Valve Wiring Harness Dispense Valve Dispense Relay Manual Repair Kit for GS56 Dispenser Valve Adjustable Gate for Dispenser Valve Product -- Rinse Button Dispense Switch Hot Chocolate Pump Hose Barb Plastic 0.250” x 0.250” Fitting Hose Barb Plastic 0.250” x 0.312” Fitting Whipper Motor Slinger Washer Self-Locating Whipper Base 1/4” ID 5/16” OD x 3/16” Bearing 0.250” x 0.616” x 0.188” Seal 0.250” x 0.070” O-Ring 4 Blade Whipper W/Stop Whipper Cover Whipper Funnel GM Whipper Chamber Angle Outlet Restrictor Whipper Assembly Clear Tygon Tubing (12-1/2”) Syrup Dispense Tubing (15”) Water Outlet Tube (3-1/2”) Water Dispense Tube (6”) Overflow Tube (1/2” OD x 24”) Cleaning Tube (1/2” OD x 12”) 1-1/8” cp. Hole Plug for Dispense Valve

Optional530-021 531-033

K2K-30-661 Portion control Timer NCC HC Red Stop Switch Button

Page 16 of the Grindmaster HC-2 user manual — HC-2 Parts List
Page 16 · click to enlarge
Page 16
Page 16 of the Grindmaster HC-2 user manual — HC-2 Parts List
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Consistent filling of water tank • Leaking fill solenoid valve • Electrode lined up or faulty • Faulty white common connection to ground • Liquid level control faulty p.9
Water not heating up • Thermostat Off • Thermostat faulty • Power relay faulty • Heating element faulty p.9
Nothing dispensed - water or chocolate - No whipper action • Dispense switch faulty p.9
No water dispensed or whipper action - Only chocolate is dispensed • Water switch faulty p.9
No water dispensed - Whipper works and chocolate is dispensed • Tank refill problem • Kinked silicone tubing • Dispense valve faulty p.9
No whipper action - only water and chocolate are dispensed • Whipper motor faulty p.9
No chocolate dispensed - Whipper works and some water is dispensed • No syrup to pump • Kinked pump tubing • Syrup pump faulty p.9
Constant dispense - chocolate, water and whipper action • Dispense switch faulty p.9
Constant water dispense or drip • Dispense valve faulty p.9
Chocolate is dispensed or constantly dripping • Syrup pump rollers not engaging silicone tubing • Pump tubing faulty p.10

Ask about the Grindmaster HC-2

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Grindmaster HC-2

Be the first to ask — other owners or our team will answer.

Original document

Grindmaster HC-2 manual PDF

16 pages·133 KB·Hot Beverage Maker·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…