Visit our website; http://MAGNUM.Graco.com
X5™, X7™, ProX7™ & ProX9™ Airless Sprayers 312667K EN
- For portable spray applications of architectural paints and coatings. For professional use only-
Models 262800, 262805, 261815, 261820 See page 3 for model and series information including dispense rate, recommended hose length, guns, and maximum working pressure.
X5 and X7 Models ONLY: Use water based or mineral-spirit type material only. Do not use materials having flash points lower than 70°F (21°C). This includes, but is not limited to, acetone, xylene, toluene, or naptha. For more information about your material request MSDS from distributor or retailer.

Related Manual


This equipment is not intended for use with flammable or combustible materials used in places such as cabinet shops or other “factory”, or fixed locations. If you intend to use this equipment in this type of application, you must comply with NFPA 33 and OSHA requirements for the use of flammable and combustible materials.





The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. Refer back to these warnings. Additional, product specific warnings may be found throughout the body of this manual where applicable.
GROUNDING This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

ti9164a


BURN HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns: • Do not touch hot fluid or equipment.


Component Identification



Component Identification

Grounding and Electric Requirements
Fluid supply container: follow local code.
Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface such as concrete. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity.
Sprayer must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for electrical current due to static build up or in the event of a short circuit.
Grounding the metal pail: connect a ground wire to the pail by clamping one end to pail and other end to ground such as a water pipe.
Maintaining grounding continuity when flushing or relieving pressure: hold metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

Motor has a thermal overload switch to shut itself down if overheated. If unit overheats, allow approximately 45 minutes for unit to cool. Once cool, switch will close and unit will restart.
Spray gun: ground through connection to a properly grounded fluid hose and pump.
To reduce risk of injury from motor starting unexpect- edly when it cools, always turn power switch OFF if motor shuts down.

Pressure Relief Procedure
See Operation manual 312001 for basic information on sprayer set-up, flushing, and storage.
Follow this Pressure Relief Procedure whenever you stop spraying and before cleaning, checking, servicing, or transporting equipment.

Always engage the trigger lock when you stop spraying to prevent the gun from being triggered accidentally by hand or if dropped or bumped.


Trigger Locked SG10 Trigger Unlocked SG10


Trigger Locked SG20, Trigger Unlocked SG20, SG2, SG3, SGPro SG2, SG3, SGPro
SG2, SG3 SG20, SGPro SG10
If you suspect the spray tip or hose is clogged or that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Clear hose or tip obstruction. Read Unclogging Spray Tip instructions in the Sprayer or Gun Operation manual. Pressure Control Knob Settings


To reduce risk of serious injury, including electric shock:
Flammable materials spilled on hot, bare, motor could cause fire or explosion. To reduce risk of burns, fire or explosion, do not operate sprayer with cover removed.
General Repair Information

Check everything in this Basic Troubleshooting table before you bring the sprayer to a Graco/MAGNUM authorized service center.
Power switch is on and sprayer is plugged in, but motor does not run, and pump does not cycle.
Pressure is set at zero pressure. Turn pressure control knob clockwise to increase pressure setting.
Electric outlet is not providing power. • Check that lighted plug on sprayer is lit (this indicates electric power at outlet).
Extension cord is damaged. Replace extension cord. Read Grounding and Electric Require- ments, page 10.
Sprayer electric cord is damaged. Check for broken insulation or wires. Replace electric cord if damaged.
Motor or control is damaged. Take sprayer to Graco/MAGNUM authorized service center.
Basic Troubleshooting · Problem Cause Solution

Pump does not prime. Prime/Spray Valve is in SPRAY posi- tion.
Turn Prime/Spray Valve to PRIME position (pointing down).
Inlet screen is clogged or suction tube is not immersed.
Clean debris off inlet screen and make sure suction tube is immersed in fluid.
Pump was not primed with flushing fluid.
Remove suction tube from paint. Prime pump with water or solvent-based flushing fluid, see Operation manual 312001.
Inlet valve check ball is stuck. Remove suction tube and place a pencil into the inlet section to dis- lodge the ball, allowing pump to prime properly. Or, Power Flush sprayer, see Operation manual 312001.
AutoPrime may need replacement. Turn power switch ON and listen for “tap” in pump. If you do not hear “tap”, AutoPrime is damaged. Take sprayer to Graco/MAGNUM authorized service center.
Inlet valve check ball or seat is dirty Remove inlet fitting. Clean or replace ball and seat.
Outlet valve check ball is stuck. ProX7 and ProX9: Insert screw driver in slot and remove Easy-Access door, page 8. Unscrew outlet valve with a 3/4 in. socket. Remove and clean assembly.
X5 and X7: Remove outlet fitting and clean outlet check ball.
Suction tube is leaking allowing air to enter.
Check suction tube for cracks and cuts. Make sure suction tube clamp is on hose. Replace suction tube if cracked or damaged.
Pump valves are worn. Check for worn valves, see page 14.
Paint is very thick or sticky. Thin material per manufacturer’s instructions.
Momentarily turn power switch OFF to allow pump to slow and stop. Repeat as necessary.
Basic Troubleshooting · Problem Cause Solution

Pump cycles but does not build up pressure.
Prime/Spray valve in PRIME position (pointing down).
Turn Prime/Spray valve to SPRAY position (pointing forward).
Pump is not primed. Prime pump, see Operation manual 312001.
Inlet screen is clogged or suction tube is not immersed.
Clean debris off inlet screen and make sure suction tube is immersed in fluid.
Suction tube is leaking, allowing air to enter.
Check suction tube for cracks and cuts. Make sure suction tube clamp is on hose. Replace suction tube if cracked or damaged.
Prime/Spray Valve is worn or obstructed with debris.
Take sprayer to Graco/MAGNUM authorized service center.
Pump check ball is stuck. Read Pump does not prime section in Troubleshooting, page 14.
Pump cycles, but paint only dribbles or spurts when spray gun is trig- gered.
Pressure is set too low. Slowly turn pressure control knob clockwise to increase pressure set- ting which will turn motor on to build pressure.
Spray tip is clogged. Unclog spray tip, see Operation man- ual 312001.
InstaClean fluid filter is clogged. (ProX7 and ProX9 Only)
Clean or replace InstaClean fluid fil- ter, see Operation manual 312001.
Spray gun fluid filter is clogged. Clean or replace gun fluid filter, see Operation manual 312001.
Spray tip is too large or worn. Replace tip.
Basic Troubleshooting · Problem Cause Solution

Pressure is set at maximum but cannot achieve a good spray pattern.
Spray tip is clogged. Unclog spray tip, see Operation manual 312001.
Reversible spray tip is in UNCLOG position.
Rotate arrow-shaped handle on spray tip so it points forward on gun.
Spray tip is too large for sprayer. Select smaller spray tip.
Spray tip is worn beyond capability of sprayer.
Replace spray tip.
Extension cord is too long or not heavy enough gauge.
Replace extension cord. See Grounding and Electrical Requirements, page 10.
Spray gun fluid filter is clogged. Clean or replace spray gun fluid filter, see Operation manual 312001.
InstaClean fluid filter is clogged. (ProX7 and ProX9 Only)
Clean or replace InstaClean fluid filter, see Operation manual 312001.
Inlet screen is clogged. Clean debris off inlet screen.
Pump valves are worn. Check for worn pump valves.
a. Prime sprayer with paint
b. Trigger gun momentarily. When trigger is released, pump should cycle momen- tarily and stop. If pump con- tinues to cycle, pump valves may be worn.
Material is too thick. Thin material.
Hose is too long (if extra section is added).
Remove extra section of hose.
Spray gun stopped spraying. Pump is not cycling.
Spray tip is clogged. Unclog spray tip, see Operation man- ual 312001.
When paint is sprayed, it runs down the wall or sags.
Coat is going on too thick. Move gun faster.
Choose a tip with smaller hole size.
Choose tip with wider fan.
Make sure gun is far enough from surface.
When paint is sprayed, coverage is inadequate.
Coat is going on too thin. Move gun slower.
Choose tip with larger hole size.
Choose tip with narrower fan.
Make sure gun is close enough to surface.
Basic Troubleshooting · Problem Cause Solution

Fan pattern varies dramatically while spraying.
Pressure control switch is worn and causing excessive pressure variation.
Take sprayer to Graco/MAGNUM authorized service center.
Sprayer does not turn on promptly when resuming spraying.
Cannot trigger spray gun. Spray gun trigger lock is locked. Rotate trigger safety lever to unlock trigger lock, page 11.
Paint is coming out of pressure control switch.
Pressure control switch is worn. Take sprayer to Graco/MAGNUM authorized service center.
Prime/Spray valve actuates automatically relieving pressure through prime tube.
System is over pressurizing. Take sprayer to Graco/MAGNUM authorized service center.
Paint leaks down outside of pump. Pump packings are worn. Take sprayer to Graco/MAGNUM authorized service center.
Motor is hot and runs intermittently. Motor automatically shuts off due to excessive heat. Damage can occur if cause is not corrected. See Thermal Overload, page 10.
Vent holes in enclosure are plugged or sprayer is covered.
Keep vent holes clear of obstructions and overspray and keep sprayer open to air.
Extension cord is too long or not a heavy enough gauge.
Replace extension cord. Read Grounding and Electrical Requirements, page 10.
Unregulated electrical generator being used has excessive voltage.
Use electrical generator with a proper voltage regulator. Sprayer requires 120VAC, 60 Hz, 1500-Watt generator.
Basic Troubleshooting · Problem Cause Solution

See Basic Troubleshooting first, page 13 for problems that are more easily remedied.
Specific Problem Cause Solution
Power switch is on and sprayer is plugged in; pump does not cycle.
See Basic Troubleshooting, page 13.
Basic mechanical problems. Paint is frozen or hardened in pump.
Unplug sprayer from electrical outlet.
If paint is frozen in sprayer:
Do NOT try to start sprayer until completely thawed or you may damage the motor, control board, and/or drivetrain.
a. Turn on sprayer.
b. Turn prime valve to PRIME position.
If paint hardened in sprayer:
ProX7 and ProX9: Replace pump packings. See List of Kits, page 28.
X5 and X7: Replace complete pump. See List of Kits, page 28.
Remove all residue from inlet and outlet valves.
Gears are damaged. Remove motor enclosure and rotate motor fan to check for bad gears. If gears bind or slip, remove pump cover and replace failed gears. See List of Kits, page 28.
ProX7 and ProX9: Yoke is broken because pump is locked up due to dried paint or worn packings.
Repair or replace using Gear/Yoke Kit. See List of Kits, page 28.
Replace pump packings on ProX7 and ProX9 sprayers. See List of Kits, page 28.
Advanced Troubleshooting

Specific Problem Cause Solution
Basic electrical problems. Motor overheated. Allow motor to cool for 45 minutes. Retry.
Electrical outlet is damaged. Reset building circuit breaker or replace fuse. Try another outlet.
Check electric supply with volt meter. Meter must read 85 to 130V AC. If voltage is too high, do not plug sprayer in until outlet is corrected.
Control board leads are improperly fastened, improperly mated, or corroded.
Replace any loose terminals. Make sure all leads and harnesses are firmly connected.
ProX7 and ProX9: Check pressure control harness connection on front side of drive housing.
Clean control board terminals. Securely reconnect leads.
Motor brushes are worn. Check length of BOTH brushes (brushes do not wear evenly on both sides of the motor). Brush length must be 0.25 in. (6.4mm). If brushes are worn replace motor using Motor Kit, page 28.
Motor armature commutator damaged.
Check for burn spots, gouges and extreme roughness. If damaged or if shorts are evident, replace motor using Motor Kit, page 28.
Fuse is blown. Find cause for blown fuse before replacing. Turn the motor fan to check for a locked gear or pump. Use a continuity meter to check for a short to ground caused by a pinched wire.
ProX7 and ProX9: Replace the fuse with correct fuse kit. See List of Kits, page 28.
X5 and X7: The fuse is not replaceable. Replace control board. See List of Kits, page 28.
Motor armature shorting. Check for shorts. See Motor Diagnostics, page 25. If shorts are evident, replace motor using Motor Kit, page 28.
Motor armature open circuit. Check motor leads for continuity. If open circuit, check brushes. Use Motor Kit to replace motor. See List of Kits, page 28.
Control board damaged.
See Control Board Diagnostics, page 27. Replace control board if damaged using Control Board Kit, page 28.
Advanced Troubleshooting

Specific Problem Cause Solution
Sprayer power cord damaged. Unplug sprayer power cord.
Disconnect black power cord wire at power switch.
Unplug in-line connection white cord wire.
Plug in power cord.
Test voltage between black and white wires of power cord. Meter must read 85 to 130V AC.
Replace power cord if no voltage.
Sprayer power switch damaged.
Motor thermal overload cutoff switch damaged.
Advanced Troubleshooting · Sprayer Wiring Problems

Specific Problem Cause Solution
Building circuit breaker opens as soon as sprayer is turned on.
Sprayer electrical wiring is pinched or insulation is damaged.
Repair or replace any damaged wiring or terminals. Securely reconnect wires.
Wires between pressure control switch and control board are pinched.
Motor armature is shorting. Check for shorts. See Motor Diagnostics, page 25. If shorts are evident, replace motor using Motor Kit, page 28.
Control board is damaged.
See Control Board Diagnostics, page 27. Replace control board if damaged using Control Board Kit, page 28.
Building circuit breaker opens as soon as sprayer is plugged into outlet and sprayer is NOT turned on.
Sprayer power cord damaged. Unplug sprayer power cord.
Disconnect black power cord wire at power switch.
Unplug in-line connection white cord wire.
Plug in power cord.
Test voltage between black and white wires of power cord. Meter must read 85 to 130V AC.
Replace power cord if no voltage.
Sprayer power switch damaged.
Also see Basic Electrical Problems, and Sprayer Wiring Problems, pages 19 - 20.
Advanced Troubleshooting

Specific Problem Cause Solution
Sprayer quits after running for 5 to 10 minutes Building circuit is overloaded. Remove other loads from building circuit or find another circuit that has less load. See Grounding and Electric Requirements, page 10.
Electrical outlet supplying wrong voltage.
Try another outlet. Check electric supply with volt meter. Meter must read 85 to 130V AC. If voltage is too high, do not use outlet until corrected.
Also see Basic Electrical Problems and Sprayer Wiring Problems, pages 19 - 20.
Motor is overheating.
After motor cools, operate sprayer and determine if motor stops when trigger on gun is released. If sprayer runs continuously, replace Pressure Control. See List of Kits, page 28.
Relieve pressure and remove motor enclosure. Turn motor fan by hand to check for binding gears or seized pump. See List of Kits, page 28.
Advanced Troubleshooting

Specific Problem Cause Solution
Pump cycles, but output is low or surging.
See Basic Troubleshooting, page 13.
Worn or obstructed inlet and outlet valves.
Check for worn pump valves as follows:
Prime sprayer with paint. Turn the Prime/Spray valve to SPRAY position. Turn pressure control fully clockwise.
Trigger spray gun briefly.
When spray gun trigger is released pump should cycle momentarily and stop.
If pump continues to cycle, pump valves may be worn or obstructed.
For replacement inlet and outlet valve kits, see List of Kits, page 28.
Prime/Spray valve is leaking out drain line when Prime/Spray valve is in SPRAY position.
Check Prime/Spray valve for debris trapped on seat and for worn parts. Torque to 130 - 180 in-lb (15.8 - 18.1 N•m). Replace if parts are worn using Prime/Spray Valve Kit, page 28.
Voltage from electrical outlet is too low. Low voltages reduce sprayer performance.
Check voltage of outlet. Meter must read 85 to 130V AC.
Extension cord is too long or not heavy enough gauge.
Replace extension cord.
See Grounding and Electrical Requirements, page 10.
Leads from motor or pressure switch to control board are damaged, loose, pinched, or overheated.
Be sure terminals are centered and firmly connected. Inspect for pinched wiring and wiring insulation and terminals for signs of overheating. Replace any loose terminals or damaged wiring. Securely reconnect terminals.
Motor brushes are worn. Check length of BOTH brushes (brushes do not wear evenly on both sides of the motor). Brush length must be 0.25 in. (6.4mm). If brushes are worn replace motor using Motor Kit, page 28.
Motor brush springs are broken. If springs are broken, replace motor using Motor Kit, page 28.
Motor brushes are binding in brush holders.
Clean brush holders. Remove carbon dust with small cleaning brush.
Motor stops before sprayer reaches correct pressure (stall pressure is too low).
Replace pressure control using Pressure Control Switch Kit, page 28.
Control board is damaged.
See Control Board Diagnostics, page 27. If damaged, replace control board using Control Board Kit, page 28.
Advanced Troubleshooting

Specific Problem Cause Solution
Motor runs and pump cycles, but pressure does not build up.
Intake valve or outlet valve is not seating properly.
Remove and clean inlet valves and outlet valves. Replace if necessary. See List of Kits, page 28.
Pump packings are worn or damaged.
Check for leaking around pump.
ProX7 and ProX9: Replace pump packings. See List of Kits, page 28.
X5 and X7: Replace complete pump. See List of Kits, page 28.
Specific Problem Cause Solution
Prime/Spray Valve actuates automatically, relieving pressure through drain tube.
Pressure control switch has pinched wires or switch is worn.
Replace pressure control switch using Pressure Control Switch Kit, page 28.
Water or paint entered pressure control switch or shorted control board.
Use Pressure Control Switch Kit, to replace switch. See List of Kits, page 28.
Control board failed. See Control Board Diagnostics, page 27. Replace damaged control board using Control Board Kit, page 28.
Advanced Troubleshooting

Motor Diagnostics (X5 and X7)
If Motor Diagnostics reveal a damaged motor or if motor brushes are shorter than 1/4 in. (6.4 mm) replace the motor using Motor Kit, page 28.
Check for electrical continuity in motor armature, windings and brush as follows:
If Motor Diagnostics reveal a damaged motor or if motor brushes are shorter than 1/4 in. (6.4 mm) or if the motor shaft cannot turn, replace the motor using Motor Kit, page 28.
Armature Short Circuit Spin Test
Quickly turn motor fan by hand. There should not be electrical shorts and fan should coast two or three revolutions before stopping. If fan does not spin freely, armature is shorted. Replace motor using Motor Kit, page 28.
Armature, Brushes and Motor Wiring Open Circuit Test (Continuity)
Setup · Setup

Pressure Control Switch Diagnostics
If pressure control switch diagnostics reveal a damaged pressure control, replace it with the correct Pressure Con- trol Switch Kit, see page 28. X5 and X7 sprayers have different pressure control kits because stall pressure is pre- set at the factory.
in connector. If either pressure control switch lead is shorted to ground, pressure control switch wires have been pinched to ground during assembly and pressure control switch needs to be replaced.
X5 and X7: Remove enclosure and disconnect pressure control switch connector from control board. Use finger to support control board when removing pressure control switch connector.

Control Board Diagnostics (ProX7 and ProX9)
Check for a damaged control board or pressure control switch as follows:
When repairing or cleaning the pump, never submerge pump in water or allow fluid to enter pressure control.
ProX7 and ProX9: Replace pump using Pump Repair kit. See List of Kits, page 28.
When pump packings wear, paint begins to leak down the outside of the pump. At the first sign of leakage, replace the pump or additional damage to the drive train could occur.

List of Kits (Series A)
Kit Number Models Kit Description
289107 X5, X7, ProX7, ProX9 AutoPrime
288706 X5, X7 Control Board
288705 ProX7 Control Board
288900 ProX9 Control Board
244035 X5, X7, ProX7, ProX9 Drain Tube Diffuser
289680 X5 Enclosure (includes labels and screws)
289681 X7 Enclosure (includes labels and screws)
288695 ProX7, ProX9 Enclosure (includes labels and screws)
287770 ProX7, ProX9 Fan Replacement
288747 ProX7, ProX9 Filter Kit (InstaClean™)
289682 X5, X7 Front Cover
288692 ProX7, ProX9 Front Cover
289209 X5, X7 Gear and Drive
289102 ProX7, ProX9 Gear/Yoke
247339 X5, X7 Hose 1/4 in. x 25 ft
247340 ProX7, ProX9 Hose 1/4 in. x 50 ft
243082 X5, X7, ProX7, ProX9 Inlet Strainer
256212 ProX7 and ProX9 Lacquer Conversion Kit
262012 X7 Leg, Left
262014 X7 Leg, Right
289915 X5, X7 Motor
289104 ProX7, ProX9 Motor
16E843 X5 (Series A), X7 (All Series) Power Cord (includes warning label)
244266 X5 Pressure Control Switch
244267 X7, ProX7, ProX9 Pressure Control Switch
235014 X5, X7, ProX7, ProX9 Prime/Spray Valve
288701 X5, X7 Pump Inlet Valve
288700 ProX7 Pump Inlet Valve
288699 ProX9 Pump Inlet Valve
289878 X5, X7 Pump Outlet Valve
243094 ProX7, ProX9 Pump Outlet Valve
288818 ProX7, ProX9 Pump Repair Kit
289650 X5, X7 Pump Replacement (Complete)
288703 ProX7 Pump Replacement (Complete)
288702 ProX9 Pump Replacement (Complete)
197607 X5 Suction Tube
15T122 X7 Suction Tube
15K617 ProX7, ProX9 Suction Tube
288709 ProX7, ProX9 Tool Box
119276 ProX7 Fuse · 119277 ProX9 Fuse

List of Kits (Series B, C, D)
Kit Number Models Kit Description
289107 X5, X7, ProX7, ProX9 AutoPrime
16E829 X5, X7 (Series B, C, D) Control Board
288705 ProX7, ProX9 Series B Control Board
288900 ProX9 Series A Control Board
244035 X5, X7, ProX7, ProX9 Drain Tube Diffuser
16E830 X5 Enclosure (includes labels and screws)
16E831 X7 Enclosure (includes labels and screws)
288695 ProX7, ProX9 Enclosure (includes labels and screws)
287770 ProX7, ProX9 Fan Replacement
288747 ProX7, ProX9 Filter Kit (InstaClean™)
16E833 X5, X7 Front Cover
288692 ProX7, ProX9 Front Cover
289102 ProX7, ProX9 Gear/Yoke
247339 X5, X7 Hose 1/4 in. x 25 ft
247340 ProX7, ProX9 Hose 1/4 in. x 50 ft
288716 X5, X7, ProX7, ProX9 Inlet Strainer
256212 ProX7 and ProX9 Lacquer Conversion Kit
24K633 X5 (Series A, B, C, D) Leg, Left
262012 X7 Leg, Left
24K632 X5 (Series A, B, C, D) Leg, Right
262014 X7 Leg, Right
289104 ProX7, ProX9 Motor
16E843 X7 Power Cord (includes warning label)
244266 X5 Pressure Control Switch
244267 X7, ProX7, ProX9 Pressure Control Switch
235014 X5, X7, ProX7, ProX9 Prime/Spray Valve
16E844 X5, X7 Pump Inlet Valve
288700 ProX7, ProX9 Series B Pump Inlet Valve
288699 ProX9 Pump Inlet Valve
16E845 X5, X7 Pump Outlet Valve
243094 ProX7, ProX9 Pump Outlet Valve
288818 ProX7, ProX9 Pump Repair Kit
16F047 X5, X7 Pump Replacement
288703 ProX7, ProX9 Series B Pump Replacement (Complete)
288702 ProX9 Pump Replacement (Complete)
243011 X5 Series C, X7, Series C Spray Gun SG2
243012 ProX9 Series B Spray Gun SG3
197607 X5 Suction Tube
15T122 X7 (Series A) Suction Tube
16E847 X7 (Series B, C) Suction Tube
15K617 ProX7, ProX9 Suction Tube
16H348 ProX9 Series B Suction Tube
24J019 ProX9 (Series B) Suction Tube Assembly
288709 ProX7, ProX9 Series A Tool Box
16E842 X5 (Series B, C, D) Power Cord (includes warning label)
16F392 X5, X7 Motor (Johnson)
16E838 X5, X7 Motor (Cinderson)
16E778 X5, X7 Gear and Drive (for Johnson motor)
16E835 X5, X7 Gear and Drive (for Cinderson motor)
119276 ProX7 Fuse · 119277 ProX9 Fuse

Ref Part Description Qty 1 289682 KIT, housing cover (includes 1a, 1b) 1 1a 120724 SCREW 4 1b 15R605 LABEL, Magnum X5, front 1 7 244266 KIT, pressure control, (includes 7a, 7b) 1 7a 15A464 LABEL, control 1 7b 15K530 LABEL, control 1 14 289650 KIT, pump, (includes 14a, 14b) 1 14a 289209 KIT, gear 1 14b 115477 SCREW, mach, torx, pan hd 4 16 289915 KIT, motor 1 17 289878 KIT, outlet valve, X5 and X7 1 22 235014 KIT, drain valve 1 23 224807 BASE, valve 1 24 187625 HANDLE, valve, drain 1 25 111600 PIN, grooved 1 26 196574 FITTING, drain 1 29 288701 KIT, pump, inlet valve (includes 29a, 29b)
Ref Part Description Qty
41 289680 KIT, enclosure, X5 (includes 1a, 41a, 41b)
41a▲15E072 LABEL, identification 1 41b 115477 SCREW, mach, torx, pan hd 4 43 260212 SCREW, hex washer hd, thd form 2 44 15R543 BRACKET, motor 1 47 24K633 KIT, left leg, X5 (includes 3 screws, 47a)
47a 125116 SCREW, hex washer hd, thd form 4 51 24K632 KIT, right leg, X5 (includes 3 screws, 47a, 47b)
66 15K744 FOAM, pump drain 1 67 16E843 KIT, power cord, X5/X7 (includes 67a, 67b)
67a 115498 SCREW, grounding 1 67b▲15T069 LABEL, Magnum, warning 1 68 15R979 WIRE, jumper 1 70 121092 CLIP, spring 1 71 198547 TAG, hang, instructional 1 72 15K551 GUIDE, Magnum quick guide, English 1 72a 15K552 GUIDE, Magnum quick guide, Spanish (not shown)
29a 105445 BALL, intake 1 29b 115719 O-RING 1 30 289107 KIT, solenoid 1 31 15R549 COVER, solenoid 1 32 288706 KIT, control board (includes 32a) 1 32a 115492 SCREW, mach, slot hex wash hd 1 33 288716 KIT, strainer 1 34 244035 DEFLECTOR, barbed 1 35 115489 CLAMP, drain tube 2 36 195084 TUBE, drain 1 37 197607 TUBE, suction 1 38 116295 CLAMP, tube 1 39 195400 CLIP, spring 2 40 118899 SWITCH, rocker, spdt 1
84 247339 HOSE, cpld, 14 in. x 25 ft 1 85 243011 GUN, spray, SG2, Magnum 1 86 121423 RETAINER, wire 1 91 115648 VALVE, shutoff (not shown) 1 92 244168 FLUID, pump armor, 8 oz (not shown) 1 93 179960 CARD, medical wallet (not shown) 1
▲ Replacement Warning labels, tags and cards are available at no cost.





Ref Part Description Qty 1 16E833 KIT, housing cover (includes 1a, 1b) 1 1a 120724 SCREW 4 1b 15R605 LABEL, Magnum X5, front 1 7 244266 KIT, pressure control (includes 7a, 7b) 1 7a 15A464 LABEL, control 1 7b 15K530 LABEL, control 1 14 16F047 KIT, pump (includes 17, 29, 43) 1 15 16E835 DRIVE (for Cinderson motor) 1 16E778 DRIVE (for Johnson motor) 1 16 16E838 KIT, motor (Cinderson) 1 16F392 KIT, motor (Johnson) 1 17 16E845 KIT, outlet valve, X5 and X7 1 18 24E510 COVER, gear 1 22 235014 KIT, drain valve 1 23 24E578 BASE, valve 1 24 187625 HANDLE, valve, drain 1 25 111600 PIN, grooved 1 29 16E844 KIT, pump, inlet valve (includes 29a, 29b, 29c)
Ref Part Description Qty
40 118899 SWITCH, rocker, spdt 1 41 16E830 KIT, enclosure, X5 (includes 1a, 41a, 41b)
41a▲15E072 LABEL, warning 1 41b 115477 SCREW, mach, torx, pan hd 4 43 112689 SCREW, button, thd form 4 44 16D682 BRACKET, motor 1 47 24K633 KIT, left leg, X5 (includes 2 screws, 47a, 47b)
47a 260212 SCREW, hex washer hd, thd form 4 47b 102040 NUT, lock, hex 4 51 24K632 KIT, right leg, X5 (includes 3 screws, 47a, 47b)
67 16E842 KIT, power cord, X5 (includes 67a, 67b) 1 67a 115498 SCREW, grounding 1 67b▲15T069 LABEL, Magnum, warning 1 68 16E212 WIRE, jumper 1 70 121092 CLIP, spring 1 71 198547 TAG, hang, instructional 1 72 15K551 GUIDE, Magnum quick guide, English 1 72a 15K552 GUIDE, Magnum quick guide, Spanish (not shown)
29a 124249 BALL, intake 1 29b 103338 O-RING 1 29c 123849 SPRING, inlet 1 30 289107 KIT, solenoid 1 31 15Y296 COVER, solenoid 1 32 16E829 KIT, control board (includes 32a) 1 32a 115477 SCREW, mach, torx 1 33 288716 KIT, strainer 1 34 244035 DEFLECTOR, barbed 1 35 115489 CLAMP, drain tube 2 36 195084 TUBE, drain 1 37 197607 TUBE, suction 1 38 116295 CLAMP, tube 1 39 195400 CLIP, spring 2
84 247339 HOSE, cpld, 14 in. x 25 ft 1 85 243011 GUN, spray, SG2, Magnum 1 86 121423 RETAINTER, wire 1 91 115648 VALVE, shutoff (not shown) 1 92 244168 FLUID, pump armor, 8 oz (not shown) 1 93 179960 CARD, medical wallet (not shown) 1
▲ Replacement Warning labels, tags and cards are available at no cost.




41b

Ref Part Description Qty 1 289682 KIT, housing cover, includes 1a, 1b 1 1a 120724 SCREW 4 1b 15R606 LABEL, Magnum X7, front 1 7 244267 KIT, pressure control, includes 7a, 7b 1 7a 15A464 LABEL, control 1 7b 15K530 LABEL, control 1 14 289650 KIT, pump, includes 14a, 14b 1 14a 289209 KIT, gear 1 14b 115477 SCREW, mach, torx pan hd 4 16 289915 KIT, motor 1 17 289878 KIT, outlet, valve 1 22 235014 KIT, drain valve 1 23 224807 BASE, valve 1 24 187625 HANDLE, valve, drain 1 25 111600 PIN, grooved 1 26 196574 FITTING, drain 1 29 288701 KIT, pump, inlet valve, includes 29a, 29b 1
Ref Part Description Qty
41d 120093 SCREW, self drilling 1 43 260212 SCREW, hex washer hd, thd form 2 44 15R587 SHELF, motor 1 47 262012 KIT, left leg, X7, includes 2 screws 47a 1 47a 260212 SCREW, hex washer hd, thd form 4 51 262014 KIT, right leg, X7, includes 2 screws 47a 1
52 120788 SCREW, carriage 2 53 15R602 AXLE, cart 1 54 115095 WHEEL, 9 in. 2 55 112612 CAP, hub 2 56 15R569 HANDLE, cart 1 57 16H350 RACK, hose 1 58 120689 NUT, hex, acorn, 5/16 - 18 nickel 2 60 115480 KNOB, t-handle 2 62 15R566 HANGER, pail 1 66 15K744 FOAM, pump drain 1 67 16E843 KIT, power cord, X5/X7, includes 67a, 67b 1
29a 105445 BALL, intake 1 29b 115719 O-RING 1 30 289107 KIT, solenoid 1 31 15R549 COVER, solenoid 1 32 288706 KIT, control board, includes 32a 1 32a 115492 SCREW, mach, slot hex wash hd 3 33 288716 KIT, strainer 1 34 244035 DEFLECTOR, barbed 1 35 115489 CLAMP, drain tube 2 36 195108 TUBE, drain 1 37 15T122 TUBE, suction 1 38 116295 CLAMP, tube 1 39 195400 CLIP, spring 1 40 118899 SWITCH, rocker, spdt 1 41 289681 KIT, enclosure, X7, includes 1a, 41a, 41b, 41c, 41d 1
67a 115498 SCREW, grounding 1 67b▲15T069 LABEL, Magnum, warning 1 68 15R979 WIRE, jumper 1 70 121092 CLIP, spring 1 71 198547 TAG, hang, instructional 1 72 15K551 GUIDE, Magnum quick guide, English 1 72a 15K552 GUIDE, Magnum quick guide, Spanish (not shown)
84 247339 HOSE, cpld, 1/4 in. x 25 ft 1 85 243011 GUN, spray, SG2, Magnum 1 86 121423 RETAINER, wire 1 91 115648 VALVE, shutoff (not shown) 1 92 244168 FLUID, pump armor, 8 oz (not shown) 1 93 179960 CARD, medical wallet (not shown) 1
41a▲15E072 LABEL, warning 1 41b 115477 SCREW, mach, torx pan hd 4 41c 121481 NUT, U-type, tinnerman 1
▲ Replacement Warning labels, tags and cards are available at no cost.





Ref Part Description Qty 1 16E833 KIT, housing cover (includes 1a, 1b) 1 1a 120724 SCREW 4 1b 15R606 LABEL, Magnum X7, front 1 7 244267 KIT, pressure control (includes 7a, 7b) 1 7a 15A464 LABEL, control 1 7b 15K530 LABEL, control 1 14 16F047 KIT, pump (includes 17, 29, 43) 1 15 16E835 KIT, drive (for Cinderson) 1 16E778 KIT, drive (for Johnson) 1 16 16E838 KIT, motor (Cinderson) 1 16F392 KIT, motor (Johnson) 1 17 16E845 KIT, outlet, valve 1 18 24E510 COVER, gear 1 22 235014 KIT, drain valve 1 23 24E578 BASE, valve 1 24 187625 HANDLE, valve, drain 1 25 111600 PIN, grooved 1 29 16E844 KIT, pump, inlet valve (includes 29a, 29b, 29c) 1
Ref Part Description Qty
41c 121481 NUT, U-type, tinnerman 1 41d 120093 SCREW, self drilling 1 43 112689 SCREW, button hd, thd form 4 44 16D683 FRAME, X7 and LTS17 1 47 262012 KIT, left leg, X7 (includes 2 screws 47a) 1 47a 260212 SCREW, hex washer hd, thd form 4 51 262014 KIT, right leg, X7 (includes 2 screws 47a)
52 120788 SCREW, carriage 2 53 15R602 AXLE, cart 1 54 115095 WHEEL, 9 in. 2 55 112612 CAP, hub 2 56 15R569 HANDLE, cart (Series B) 1 16H354 HANDLE, cart (Series C) 1 57 16H350 RACK, hose 1 58 120689 NUT, hex, acorn, 5/16 - 18 nickel 2 60 115480 KNOB, t-handle 2 62 16D907 HANGER, pail 1 67 16E843 KIT, power cord, X7 (includes 67a, 67b) 1 67a 115498 SCREW, grounding 1 67b▲15T069 LABEL, Magnum, warning 1 68 16E212 WIRE, jumper 1 70 121092 CLIP, spring 1 71 198547 TAG, hang, instructional 1 72 15K551 GUIDE, Magnum quick guide, English 1 72a 15K552 GUIDE, Magnum quick guide, Spanish (not shown)
29a 124249 BALL, intake 1 29b 103338 O-RING 1 29c 123849 SPRING, inlet 1 30 289107 KIT, solenoid 1 31 15Y296 COVER, solenoid 1 32 16E829 KIT, control board (includes 32a) 1 32a 115477 SCREW, mach, torx 3 33 288716 KIT, strainer 1 34 244035 DEFLECTOR, barbed 1 35 115489 CLAMP, drain tube 2 36 195108 TUBE, drain 1 37 15T122 TUBE, suction 1 38 116295 CLAMP, tube 1 39 195400 CLIP, spring 1 40 118899 SWITCH, rocker, spdt 1 41 16E831 KIT, enclosure, X7 (includes 1a, 41a, 41b, 41c, 41d) 1
84 247339 HOSE, cpld, 1/4 in. x 25 ft 1 85 243012 GUN, spray, SG3, Magnum 1 86 121423 RETAINER, wire 1 91 115648 VALVE, shutoff (not shown) 1 92 244168 FLUID, pump armor, 8 oz (not shown) 1 93 179960 CARD, medical wallet (not shown) 1
▲ Replacement Warning labels, tags and cards are available at no cost.
41a▲15E072 LABEL, warning 1 41b 115477 SCREW, mach, torx pan hd 4


1a


41a

Ref. Part Description Qty. 1 15J632 LEG, Series A 2 2 15J633 SUPPORT, frame, Series A 2 3 15J641 PULL ROD, Series A 1 4 15J675 SPACER, frame, Series A 4 5 15J678 BRACKET, Series A 2 6 15J691 AXLE PIN, Series A 2 7 15J695 TUBE CAP 2 8 15J699 TUBE CAP 4 9 247313 ACTUATOR, Series A 1 10 119547 NUT, hex, lock, nylon, 1/2-13 in. Series A 2 12 247314 COVER, side, Series A 1 15 15J941 PIN, Series A 4 16 16H350 HOSE RACK 1 17 15J950 CART HANDLE, Series A 1 16H353 CART HANDLE, Pro X7, ProX9 Series B 1 18 15J984 SPACER, linkage, Series A 2 19 15J985 BRACE, center, Series A 1 20 288458 BRACKET, frame, Series A 1 21 112612 HUB CAP 2 22 15J681 BAR, linkage, Series A 2 25 117630 SCREW, torx, 1/4-20 x .50 in. taptite, Series A
Ref. Part Description Qty.
288900 KIT, control, ProX9, Series A 1 62 244267 KIT, pressure control, includes 62a, 62b 1 62a 15K530 LABEL, control 1 62b 15A464 LABEL, control 1 63 288703 KIT, pump, (complete) ProX7, ProX9, Series B, includes 37, 39, 40, 51, 63a, 63b, 63c, 63d, 63e
288702 KIT, pump (complete) ProX9, Series A, includes 37, 39, 40, 51, 63a, 63b, 63c, 63d, 63e
63a 288747 KIT, filter 1 63b 288700 KIT, pump inlet module, ProX7, ProX9, Series B
288699 KIT, pump inlet module, ProX9, Series A 1 63c 288818 KIT, packing repair 1 63d 243094 KIT, pump outlet valve 1 63e 195947 ADAPTER, filter 1 63f 115719 PACKING, o-ring 1 63g 289820 KIT, pump housing 66 288709 KIT, tool box Series A 1 67 288692 KIT, housing cover, includes 67a, 67b, 67c 1
27 120688 SPRING, compression, Series A 2 28 120689 NUT, hex, acorn, 5/16-18 2 29 15K617 SUCTION TUBE (Series A), includes 35 1 16H348 SUCTION TUBE (ProX9 Series B), includes 35
67a 15J809 COVER, pump outlet 1 67b 115478 SCREW, mach, 1/4 x 20 x 1.375 in. taptite
67c 15K492 LABEL, front, ProX7 1 15K493 LABEL, front, ProX9 1 68 289104 KIT, motor, includes 68a 1 68a 287770 KIT, fan 1 75 101005 RING, retaining, ext. Series A 6 76 16A696 WHEEL,10 inch, ProX7, Series A 2 115094 WHEEL,10 inch, ProX9, Series A 2 115095 WHEEL, 9 inch, Pro X7, ProX9, Series B 81 260212 SCREW, hw hd, thd form 1/4-20 x .75 in. 10 SCREW, hw hd, thd form 1/4-20 x .75 in. ProX9, Series B
30 288716 KIT, Strainer 1 31 116295 TUBE CLAMP 1 32 195108 DRAIN TUBE 1 33 244035 DEFLECTOR 1 34 115489 DRAIN TUBE CLAMP 2 35 115099 WASHER 1 37 235014 KIT, drain valve 1 38 115648 SHUTOFF VALVE (not shown) 1 39 187625 DRAIN VALVE HANDLE 1 40 224807 BASE, valve 1 41 247340 HOSE, cpld,1/4 in. x 50 ft '1 42 289102 KIT, gear and yoke 1 43 244168 FLUID, pump armor, 8 oz (not shown) 1 44 118899 ROCKER SWITCH 1 45 288695 KIT, Motor Shield, includes 45a, 45b, 45c, 45d 1
82 120788 SCREW, carriage, 1/4-20 x 3 in. 2 83 115480 T-HANDLE KNOB 2 85 SERIAL LABEL 2 88 198547 HANG TAG, instructional (not shown) 1 92 179960 SIGN, warning (not shown) 1 93 15K551 QUICK GUIDE, English (not shown) 1 15K552 QUICK GUIDE, Spanish (not shown) 1 110 243012 GUN, spray, SG3, Magnum 1 116 121939 SCREW, plastite, Series A 6 SCREW, plastite, Series B 3 117 16F372 SHELF, motor, Pro X7, ProX9, Series B 1 118 262014 KIT, right leg, Pro X7, ProX9, Series B (includes 3 screws 81)
45a▲15K521 LABEL, warning skin injection 1 45b▲15K522 LABEL, warning fire explosion 1 45c▲15K520 LABEL, warning elec shock 1 45d 118444 SCREW, mach, hwhd 10-24 x .5 in. 2 46 15J802 SOLENOID COVER 1 47 15J803 SWITCH BRACKET 1 49 194507 DOWEL PIN, 5/16 2 50 196001 WASHER 2 51 111600 PIN, grooved 1 52 115498 SCREW, ground, 8-32 x .375 in. taptite 1 53 195400 SPRING CLIP 1 55 289107 KIT, solenoid 1 56 119275 WIRE CLIP 1 57 15J790 PAIL HOOK 1 58 15J952 POWER CORD, lighted 1 59 288705 KIT, control, ProX7, ProX9 Series B 1
119 262012 KIT, left leg, Pro X7, ProX9, Series B (includes 3 screws 81)
120 24J019 TUBE, suction assy, ProX9, series B (includes 29, 31, 32, 33, 34, 53)
▲Replacement Warning labels, tags, and cards are available
at no cost.




ti9504b



X5 and X7 Models 262800 and 262805 (Series A)
/./&& 37)4#(
0/7%2#/2$ '2%%.7)2%
#(!33)3 '2/5.$
02%3352% 37)4#( Thermal Switch 1
7)2).'$)!'2!-
1 When assembling motor to pump housing, make sure Thermal Switch is positioned on top as shown above.

X5 and X7 Models 262800 (Series B, C, D) and 262805 (Series D, C)
POWERCORD BLACK WIRE
POWERCORD WHITE WIRE
AUTO PRIME
POWERCORD GREEN WIRE
WHITE BOARD WIRE
CHASSIS GROUND
10A FUSE
PRESSURE SWITCH
WIRING DIAGRAM
Wiring Diagrams · Ref 67a · ti15763a

/./&& 37)4#(
'2.
#/.42/,"/!2$
#(!33)3'2/5.$

MAGNUM X5 (Series A - C)
M AGNUM X7
Working pressure range 0-2800 psi (0-19 MPa,
0-3000 psi (0-21 MPa,
0-3000 psi (0-21 MPa,
Electric motor 9.0A (open frame, universal)
9.0A (open frame, universal)
9.0A (open frame, universal)
Operating horsepower 1/2 1/2 5/8
Maximum delivery (with tip) 0.24 gpm (0.91 lpm) 0.27 gpm (1.02 lpm) 0.31 gpm (1.17 lpm)
Paint hose 1/4 in. x 25 ft (6.4 mm x 7.5 m)
1/4 in. x 25 ft (6.4 mm x 7.5 m)
1/4 in. x 25 ft (6.4 mm x 7.5 m)
Maximum tip hole size 0.015 in. (0.38 mm) 0.015 in. (0.38 mm) 0.017 in. (0.43 mm)
Weight, sprayer only 13.3 lb (6.0 kg) 13.3 lb (6.0 kg) 23.3 lb (10.6 kg)
Weight, sprayer, hose & gun 16.5 lb (7.5 kg) 16.5 lb (7.5 kg) 26.5 lb (12.0 kg)
Dimensions (Upright):
Length 14.5 in. (36.8 cm) 14.5 in. (36.8 cm) 19.3 in. (49.0 cm)
Width 12.4 in. (31.5 cm) 12.4 in. (31.5 cm) 15.3 in. (38.9 cm)
Height 17.9 in. (45.5 cm) 17.9 in. (45.5 cm) 37.0 in. (94.0 cm)
Dimensions (Folded):
Length N/A N/A 19.3 in. (49.0 cm)
Width N/A N/A 15.3 in. (38.9 cm)
Height N/A N/A 29.2 in. (74.2 cm)
Power cord 18 AWG, 3-wire, 6 ft (1.8 m)
Fluid inlet fitting 3/4 in. internal thread (standard garden hose thread)
Fluid outlet fitting 1/4 NPSM external thread
Inlet screen (on suction tube) 35 mesh (450 micron)
Wetted parts, pump & hose stainless steel, brass, leather, ultra-high molecular weight polyethylene
(UHMWPE), carbide, nylon, aluminum, PVC, polypropylene,
Wetted parts, gun aluminum, brass, carbide, nylon, plated steel, stainless steel,
Generator requirement 1500 Watt minimum
Electrical power requirement 120 Vac, 60 Hz, 15A, 1 phase
Storage temperature range ◆❖ -30° to 160°F (-35° to 71°C)
Operating temperature range ✔ 40° to 115°F (4° to 46°C)
◆When pump is stored with non-freezing fluid. Pump damage will occur if water or latex paint freezes in pump. ❖Damage to plastic parts may result if impact occurs in low temperature conditions. ✔Changes in paint viscosity at very low or very high temperatures can affect sprayer performance.

Working pressure range 0-3000 psi (0-21 MPa,
0-3000 psi (0-21 MPa,
0-3000 psi (0-21 MPa,
Electric motor 5.8A (open frame, permanent magnet DC)
9.4A (open frame, permanent magnet DC)
Operating horsepower 3/4 7/8
Maximum delivery (with tip) 0.34 gpm (1.29 lpm) 0.38 gpm (1.44 lpm) 0.38 gpm (1.44 lpm)
Paint hose 1/4 in. x 50 ft (6.4 mm x 15 m)
1/4 in. x 50 ft (6.4 mm x 15 m)
1/4 in. x 50 ft (6.4 mm x 15 m)
Maximum tip hole size 0.017 in. (0.43 mm) 0.019 in. (0.48 mm) 0.019 in. (0.48 mm)
Weight, sprayer only 43 lb (20 kg) 43 lb (20 kg) 33 lb (15 kg)
Weight, sprayer, hose & gun 46 lb (21 kg) 46 lb (21 kg) 36 lb (16 kg)
Dimensions (Upright):
Length 23.75 in. (60.32 cm) 23.75 in. (60.32 cm) 21.25 in. (54 cm)
Width 17.5 in. (44.45 cm) 19.25 in. (48.89 cm) 15.25 in. (38.7 cm)
Height 36.5 in. (92.71 cm) 36.5 in. (92.71 cm) 36.75 in. (93 cm)
Dimensions (Folded):
Length 23.25 in. (59.05 cm) 23.25 in. (59.05 cm) 21.25 in. (54 cm).
Width 17.5 in. (44.45 cm) 19.25 in. (48.89 cm) 15.25 in. (38.7 cm)
Height 22.00 in. (55.88 cm) 22.00 in. (55.88 cm) 30 in. (76 cm)
Power cord 16 AWG, 3-wire, 6 ft (1.8 m)
Fluid inlet fitting 3/4 in. internal thread (standard garden hose thread)
Fluid outlet fitting 1/4 NPSM external thread
Inlet screen (on suction tube) 35 mesh (450 micron)
Wetted parts, pump & hose stainless steel, brass, leather, ultra-high molecular weight polyethylene (UHMWPE), carbide, nylon, aluminum, PVC,
Wetted parts, gun aluminum, brass, carbide, nylon, plated steel, stainless steel,
Generator requirement 1500 Watt minimum
Electrical power requirement 120 Vac, 60 Hz, 15A, 1 phase
Storage temperature range ◆❖ -30° to 160°F (-35° to 71°C)
Operating temperature range ✔ 40° to 115°F (4° to 46°C)
◆When pump is stored with non-freezing fluid. Pump damage will occur if water or latex paint freezes in pump. ❖Damage to plastic parts may result if impact occurs in low temperature conditions. ✔Changes in paint viscosity at very low or very high temperatures can affect sprayer performance.


Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English.
Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
TO PLACE AN ORDER or to identify the nearest Graco/MAGNUM distributor, contact us at 1-888-541-9788
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
Original instructions. This manual contains English. MM 312667
Copyright 2008, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Revised September 2013
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Power switch is on and sprayer is plugged in, but motor does not run, and pump does not cycle. | Pressure is set at zero pressure. | Turn pressure control knob clockwise to increase pressure setting. | p.13 |
| Power switch is on and sprayer is plugged in, but motor does not run, and pump does not cycle. | Electric outlet is not providing power. | • Check that lighted plug on sprayer is lit (this indicates electric power at outlet). • Reset building circuit breaker or replace fuse. | p.13 |
| Power switch is on and sprayer is plugged in, but motor does not run, and pump does not cycle. | Extension cord is damaged. | Replace extension cord. Read Grounding and Electric Require- ments, page 10. | p.13 |
| Power switch is on and sprayer is plugged in, but motor does not run, and pump does not cycle. | Sprayer electric cord is damaged. | Check for broken insulation or wires. Replace electric cord if damaged. | p.13 |
| Power switch is on and sprayer is plugged in, but motor does not run, and pump does not cycle. | Motor or control is damaged. | Take sprayer to Graco/MAGNUM authorized service center. | p.13 |
| Pump does not prime. | Prime/Spray Valve is in SPRAY posi- tion. | Turn Prime/Spray Valve to PRIME position (pointing down). | p.14 |
| Pump does not prime. | Inlet screen is clogged or suction tube is not immersed. | Clean debris off inlet screen and make sure suction tube is immersed in fluid. | p.14 |
| Pump does not prime. | Pump was not primed with flushing fluid. | Remove suction tube from paint. Prime pump with water or solvent-based flushing fluid, see Operation manual 312001. | p.14 |
| Pump does not prime. | Inlet valve check ball is stuck. | Remove suction tube and place a pencil into the inlet section to dis- lodge the ball, allowing pump to prime properly. Or, Power Flush sprayer, see Operation manual 312001. | p.14 |
| Pump does not prime. | AutoPrime may need replacement. Turn power switch ON and listen for “tap” in pump. If you do not hear “tap”, AutoPrime is damaged. Take sprayer to Graco/MAGNUM authorized service center. | p.14 | |
| Pump does not prime. | Inlet valve check ball or seat is dirty | Remove inlet fitting. Clean or replace ball and seat. | p.14 |
| Pump does not prime. | Outlet valve check ball is stuck. | ProX7 and ProX9: Insert screw driver in slot and remove Easy-Access door, page 8. Unscrew outlet valve with a 3/4 in. socket. Remove and clean assembly. X5 and X7: Remove outlet fitting and clean outlet check ball. | p.14 |
| Pump does not prime. | Suction tube is leaking allowing air to enter. | Check suction tube for cracks and cuts. Make sure suction tube clamp is on hose. Replace suction tube if cracked or damaged. | p.14 |
| Pump does not prime. | Pump valves are worn. | Check for worn valves, see page 14. | p.14 |
| Pump does not prime. | Paint is very thick or sticky. | Thin material per manufacturer’s instructions. Momentarily turn power switch OFF to allow pump to slow and stop. Repeat as necessary. | p.14 |
| Pump cycles but does not build up pressure. | Prime/Spray valve in PRIME position (pointing down). | Turn Prime/Spray valve to SPRAY position (pointing forward). | p.15 |
| Pump cycles but does not build up pressure. | Pump is not primed. | Prime pump, see Operation manual 312001. | p.15 |
| Pump cycles but does not build up pressure. | Inlet screen is clogged or suction tube is not immersed. | Clean debris off inlet screen and make sure suction tube is immersed in fluid. | p.15 |
| Pump cycles but does not build up pressure. | Suction tube is leaking, allowing air to enter. | Check suction tube for cracks and cuts. Make sure suction tube clamp is on hose. Replace suction tube if cracked or damaged. | p.15 |
| Pump cycles but does not build up pressure. | Prime/Spray Valve is worn or obstructed with debris. | Take sprayer to Graco/MAGNUM authorized service center. | p.15 |
| Pump cycles but does not build up pressure. | Pump check ball is stuck. | Read Pump does not prime section in Troubleshooting, page 14. | p.15 |
| Pump cycles, but paint only dribbles or spurts when spray gun is trig- gered. | Pressure is set too low. | Slowly turn pressure control knob clockwise to increase pressure set- ting which will turn motor on to build pressure. | p.15 |
| Pump cycles, but paint only dribbles or spurts when spray gun is trig- gered. | Spray tip is clogged. | Unclog spray tip, see Operation man- ual 312001. | p.15 |
| Pump cycles, but paint only dribbles or spurts when spray gun is trig- gered. | InstaClean fluid filter is clogged. (ProX7 and ProX9 Only) | Clean or replace InstaClean fluid fil- ter, see Operation manual 312001. | p.15 |
| Pump cycles, but paint only dribbles or spurts when spray gun is trig- gered. | Spray gun fluid filter is clogged. | Clean or replace gun fluid filter, see Operation manual 312001. | p.15 |
| Pump cycles, but paint only dribbles or spurts when spray gun is trig- gered. | Spray tip is too large or worn. | Replace tip. | p.15 |
| Pressure is set at maximum but cannot achieve a good spray pattern. | Spray tip is clogged. | Unclog spray tip, see Operation manual 312001. | p.16 |
| Pressure is set at maximum but cannot achieve a good spray pattern. | Reversible spray tip is in UNCLOG position. | Rotate arrow-shaped handle on spray tip so it points forward on gun. | p.16 |
| Pressure is set at maximum but cannot achieve a good spray pattern. | Spray tip is too large for sprayer. | Select smaller spray tip. | p.16 |
| Pressure is set at maximum but cannot achieve a good spray pattern. | Spray tip is worn beyond capability of sprayer. | Replace spray tip. | p.16 |
| Pressure is set at maximum but cannot achieve a good spray pattern. | Extension cord is too long or not heavy enough gauge. | Replace extension cord. See Grounding and Electrical Requirements, page 10. | p.16 |
| Pressure is set at maximum but cannot achieve a good spray pattern. | Spray gun fluid filter is clogged. | Clean or replace spray gun fluid filter, see Operation manual 312001. | p.16 |
| Pressure is set at maximum but cannot achieve a good spray pattern. | InstaClean fluid filter is clogged. (ProX7 and ProX9 Only) | Clean or replace InstaClean fluid filter, see Operation manual 312001. | p.16 |
| Pressure is set at maximum but cannot achieve a good spray pattern. | Inlet screen is clogged. | Clean debris off inlet screen. | p.16 |
| Pressure is set at maximum but cannot achieve a good spray pattern. | Pump valves are worn. | Check for worn pump valves. a. Prime sprayer with paint b. Trigger gun momentarily. When trigger is released, pump should cycle momen- tarily and stop. If pump con- tinues to cycle, pump valves may be worn. | p.16 |
| Pressure is set at maximum but cannot achieve a good spray pattern. | Material is too thick. | Thin material. | p.16 |
| Pressure is set at maximum but cannot achieve a good spray pattern. | Hose is too long (if extra section is added). | Remove extra section of hose. | p.16 |
| Spray gun stopped spraying. Pump is not cycling. | Spray tip is clogged. | Unclog spray tip, see Operation man- ual 312001. | p.16 |
| When paint is sprayed, it runs down the wall or sags. | Coat is going on too thick. | Move gun faster. | p.16 |
| When paint is sprayed, it runs down the wall or sags. | Choose a tip with smaller hole size. | p.16 | |
| When paint is sprayed, it runs down the wall or sags. | Choose tip with wider fan. | p.16 | |
| When paint is sprayed, it runs down the wall or sags. | Make sure gun is far enough from surface. | p.16 | |
| When paint is sprayed, coverage is inadequate. | Coat is going on too thin. | Move gun slower. | p.16 |
| When paint is sprayed, coverage is inadequate. | Choose tip with larger hole size. | p.16 | |
| When paint is sprayed, coverage is inadequate. | Choose tip with narrower fan. | p.16 | |
| When paint is sprayed, coverage is inadequate. | Make sure gun is close enough to surface. | p.16 | |
| Fan pattern varies dramatically while spraying. OR Sprayer does not turn on promptly when resuming spraying. | Pressure control switch is worn and causing excessive pressure variation. | Take sprayer to Graco/MAGNUM authorized service center. | p.17 |
| Cannot trigger spray gun. | Spray gun trigger lock is locked. | Rotate trigger safety lever to unlock trigger lock, page 11. | p.17 |
| Paint is coming out of pressure control switch. | Pressure control switch is worn. | Take sprayer to Graco/MAGNUM authorized service center. | p.17 |
| Prime/Spray valve actuates automatically relieving pressure through prime tube. | System is over pressurizing. | Take sprayer to Graco/MAGNUM authorized service center. | p.17 |
| Paint leaks down outside of pump. | Pump packings are worn. | Take sprayer to Graco/MAGNUM authorized service center. | p.17 |
| Motor is hot and runs intermittently. Motor automatically shuts off due to excessive heat. Damage can occur if cause is not corrected. See Thermal Overload, page 10. | Vent holes in enclosure are plugged or sprayer is covered. | Keep vent holes clear of obstructions and overspray and keep sprayer open to air. | p.17 |
| Motor is hot and runs intermittently. Motor automatically shuts off due to excessive heat. Damage can occur if cause is not corrected. See Thermal Overload, page 10. | Extension cord is too long or not a heavy enough gauge. | Replace extension cord. Read Grounding and Electrical Requirements, page 10. | p.17 |
| Motor is hot and runs intermittently. Motor automatically shuts off due to excessive heat. Damage can occur if cause is not corrected. See Thermal Overload, page 10. | Unregulated electrical generator being used has excessive voltage. | Use electrical generator with a proper voltage regulator. Sprayer requires 120VAC, 60 Hz, 1500-Watt generator. | p.17 |
| Power switch is on and sprayer is plugged in; pump does not cycle. | See Basic Troubleshooting, page 13. | p.18 | |
| Basic mechanical problems. | Paint is frozen or hardened in pump. | Unplug sprayer from electrical outlet. If paint is frozen in sprayer: Do NOT try to start sprayer until completely thawed or you may damage the motor, control board, and/or drivetrain. 1. Turn power switch OFF. 2. Place sprayer in warm area for several hours. 3. Plug sprayer in. 4. Turn power switch ON and flush sprayer with water or mineral spirits. a. Turn on sprayer. b. Turn prime valve to PRIME position. If paint hardened in sprayer: ProX7 and ProX9: Replace pump packings. See List of Kits, page 28. X5 and X7: Replace complete pump. See List of Kits, page 28. Remove all residue from inlet and outlet valves. | p.18 |
| Basic mechanical problems. | Gears are damaged. | Remove motor enclosure and rotate motor fan to check for bad gears. If gears bind or slip, remove pump cover and replace failed gears. See List of Kits, page 28. | p.18 |
| Basic mechanical problems. | ProX7 and ProX9: Yoke is broken because pump is locked up due to dried paint or worn packings. | Repair or replace using Gear/Yoke Kit. See List of Kits, page 28. | p.18 |
| Basic mechanical problems. | Replace pump packings on ProX7 and ProX9 sprayers. See List of Kits, page 28. | p.18 | |
| Basic electrical problems. | Motor overheated. | Allow motor to cool for 45 minutes. Retry. | p.19 |
| Basic electrical problems. | Electrical outlet is damaged. | Reset building circuit breaker or replace fuse. Try another outlet. Check electric supply with volt meter. Meter must read 85 to 130V AC. If voltage is too high, do not plug sprayer in until outlet is corrected. | p.19 |
| Basic electrical problems. | Control board leads are improperly fastened, improperly mated, or corroded. | Replace any loose terminals. Make sure all leads and harnesses are firmly connected. ProX7 and ProX9: Check pressure control harness connection on front side of drive housing. Clean control board terminals. Securely reconnect leads. | p.19 |
| Basic electrical problems. | Motor brushes are worn. | Check length of BOTH brushes (brushes do not wear evenly on both sides of the motor). Brush length must be 0.25 in. (6.4mm). If brushes are worn replace motor using Motor Kit, page 28. | p.19 |
| Basic electrical problems. | Motor armature commutator damaged. | Check for burn spots, gouges and extreme roughness. If damaged or if shorts are evident, replace motor using Motor Kit, page 28. | p.19 |
| Basic electrical problems. | Fuse is blown. | Find cause for blown fuse before replacing. Turn the motor fan to check for a locked gear or pump. Use a continuity meter to check for a short to ground caused by a pinched wire. ProX7 and ProX9: Replace the fuse with correct fuse kit. See List of Kits, page 28. X5 and X7: The fuse is not replaceable. Replace control board. See List of Kits, page 28. | p.19 |
| Basic electrical problems. | Motor armature shorting. | Check for shorts. See Motor Diagnostics, page 25. If shorts are evident, replace motor using Motor Kit, page 28. | p.19 |
| Basic electrical problems. | Motor armature open circuit. | Check motor leads for continuity. If open circuit, check brushes. Use Motor Kit to replace motor. See List of Kits, page 28. | p.19 |
| Basic electrical problems. | Control board damaged. CAUTION: Do not perform control board diagnostics until you have determined the armature is good. A damaged armature can burn out a good control board. | See Control Board Diagnostics, page 27. Replace control board if damaged using Control Board Kit, page 28. | p.19 |
| Sprayer Wiring Problems NOTE: Remove enclosure mounting screws and pull enclosure away from drive housing. Take care not to pull on leads from electrical cord and power switch. | Sprayer power cord damaged. | Unplug sprayer power cord. Disconnect black power cord wire at power switch. Unplug in-line connection white cord wire. Plug in power cord. Test voltage between black and white wires of power cord. Meter must read 85 to 130V AC. Replace power cord if no voltage. | p.20 |
| Sprayer Wiring Problems NOTE: Remove enclosure mounting screws and pull enclosure away from drive housing. Take care not to pull on leads from electrical cord and power switch. | Sprayer power switch damaged. | 1. Unplug sprayer power cord. 2. Disconnect black control board wire at power switch. 3. Unplug in-line connection white cord wire. 4. Plug in power cord. 5. Turn power switch ON. 6. Test voltage between open terminal of power switch and white power cord wire. Meter must read 85 to 130V AC. 7. Replace power switch if no voltage. | p.20 |
| Sprayer Wiring Problems NOTE: Remove enclosure mounting screws and pull enclosure away from drive housing. Take care not to pull on leads from electrical cord and power switch. | Motor thermal overload cutoff switch damaged. WARNING: See Startup Hazard After Thermal Overload on page 10. | 1. Unplug sprayer power cord. 2. Remove motor harness from control card. 3. Check for continuity between yellow leads or motor harness (ProX7 and ProX9 only). 4. If thermal relief switch is open (no continuity) allow motor to cool. 5. If switch remains open after motor cools, replace motor using Motor Kit, page 28. 6. If thermal relief switch closes after motor cools, find correct cause of overheating. | p.20 |
| Building circuit breaker opens as soon as sprayer is turned on. NOTE: Remove enclosure mounting screws and pull enclosure away from drive housing. Take care not to pull on leads from electrical cord and power switch. | Sprayer electrical wiring is pinched or insulation is damaged. | Repair or replace any damaged wiring or terminals. Securely reconnect wires. | p.21 |
| Building circuit breaker opens as soon as sprayer is turned on. NOTE: Remove enclosure mounting screws and pull enclosure away from drive housing. Take care not to pull on leads from electrical cord and power switch. | Wires between pressure control switch and control board are pinched. | p.21 | |
| Building circuit breaker opens as soon as sprayer is turned on. NOTE: Remove enclosure mounting screws and pull enclosure away from drive housing. Take care not to pull on leads from electrical cord and power switch. | Motor armature is shorting. | Check for shorts. See Motor Diagnostics, page 25. If shorts are evident, replace motor using Motor Kit, page 28. | p.21 |
| Building circuit breaker opens as soon as sprayer is turned on. NOTE: Remove enclosure mounting screws and pull enclosure away from drive housing. Take care not to pull on leads from electrical cord and power switch. | Control board is damaged. CAUTION: Do not perform control board diagnostics until you have determined the armature is good. A bad motor armature can burn out a good motor control board. | See Control Board Diagnostics, page 27. Replace control board if damaged using Control Board Kit, page 28. | p.21 |
| Building circuit breaker opens as soon as sprayer is plugged into outlet and sprayer is NOT turned on. NOTE: Remove enclosure mounting screws and pull enclosure away from drive housing. Take care not to pull on leads from electrical cord and power switch. | Sprayer power cord damaged. | Unplug sprayer power cord. Disconnect black power cord wire at power switch. Unplug in-line connection white cord wire. Plug in power cord. Test voltage between black and white wires of power cord. Meter must read 85 to 130V AC. Replace power cord if no voltage. | p.21 |
| Building circuit breaker opens as soon as sprayer is plugged into outlet and sprayer is NOT turned on. NOTE: Remove enclosure mounting screws and pull enclosure away from drive housing. Take care not to pull on leads from electrical cord and power switch. | Sprayer power switch damaged. | 1. Unplug sprayer power cord. 2. Disconnect black control board wire at power switch. 3. Unplug in-line connection white cord wire. 4. Plug in power cord. 5. Turn power switch ON. 6. Test voltage between open terminal of power switch and white power cord wire. Meter must read 85 to 130V AC. 7. Replace power switch if no voltage. | p.21 |
| Building circuit breaker opens as soon as sprayer is plugged into outlet and sprayer is NOT turned on. NOTE: Remove enclosure mounting screws and pull enclosure away from drive housing. Take care not to pull on leads from electrical cord and power switch. | Also see Basic Electrical Problems, and Sprayer Wiring Problems, pages 19 - 20. | p.21 | |
| Sprayer quits after running for 5 to 10 minutes | Building circuit is overloaded. | Remove other loads from building circuit or find another circuit that has less load. See Grounding and Electric Requirements, page 10. | p.22 |
| Sprayer quits after running for 5 to 10 minutes | Electrical outlet supplying wrong voltage. | Try another outlet. Check electric supply with volt meter. Meter must read 85 to 130V AC. If voltage is too high, do not use outlet until corrected. | p.22 |
| Sprayer quits after running for 5 to 10 minutes | Also see Basic Electrical Problems and Sprayer Wiring Problems, pages 19 - 20. | p.22 | |
| Sprayer quits after running for 5 to 10 minutes | Motor is overheating. Warning: See Thermal Overload, page 10. | After motor cools, operate sprayer and determine if motor stops when trigger on gun is released. If sprayer runs continuously, replace Pressure Control. See List of Kits, page 28. Relieve pressure and remove motor enclosure. Turn motor fan by hand to check for binding gears or seized pump. See List of Kits, page 28. | p.22 |
| Pump cycles, but output is low or surging. | See Basic Troubleshooting, page 13. | p.23 | |
| Pump cycles, but output is low or surging. | Worn or obstructed inlet and outlet valves. | Check for worn pump valves as follows: Prime sprayer with paint. Turn the Prime/Spray valve to SPRAY position. Turn pressure control fully clockwise. Trigger spray gun briefly. When spray gun trigger is released pump should cycle momentarily and stop. If pump continues to cycle, pump valves may be worn or obstructed. For replacement inlet and outlet valve kits, see List of Kits, page 28. | p.23 |
| Pump cycles, but output is low or surging. | Prime/Spray valve is leaking out drain line when Prime/Spray valve is in SPRAY position. | Check Prime/Spray valve for debris trapped on seat and for worn parts. Torque to 130 - 180 in-lb (15.8 - 18.1 N•m). Replace if parts are worn using Prime/Spray Valve Kit, page 28. | p.23 |
| Pump cycles, but output is low or surging. | Voltage from electrical outlet is too low. Low voltages reduce sprayer performance. | Check voltage of outlet. Meter must read 85 to 130V AC. | p.23 |
| Pump cycles, but output is low or surging. | Extension cord is too long or not heavy enough gauge. | Replace extension cord. See Grounding and Electrical Requirements, page 10. | p.23 |
| Pump cycles, but output is low or surging. | Leads from motor or pressure switch to control board are damaged, loose, pinched, or overheated. | Be sure terminals are centered and firmly connected. Inspect for pinched wiring and wiring insulation and terminals for signs of overheating. Replace any loose terminals or damaged wiring. Securely reconnect terminals. | p.23 |
| Pump cycles, but output is low or surging. | Motor brushes are worn. | Check length of BOTH brushes (brushes do not wear evenly on both sides of the motor). Brush length must be 0.25 in. (6.4mm). If brushes are worn replace motor using Motor Kit, page 28. | p.23 |
| Pump cycles, but output is low or surging. | Motor brush springs are broken. | If springs are broken, replace motor using Motor Kit, page 28. | p.23 |
| Pump cycles, but output is low or surging. | Motor brushes are binding in brush holders. | Clean brush holders. Remove carbon dust with small cleaning brush. | p.23 |
| Pump cycles, but output is low or surging. | Motor stops before sprayer reaches correct pressure (stall pressure is too low). | Replace pressure control using Pressure Control Switch Kit, page 28. | p.23 |
| Pump cycles, but output is low or surging. | Control board is damaged. CAUTION: Do not perform control board diagnostics until you have determined the armature is good. A damaged armature can burn out a good control board. | See Control Board Diagnostics, page 27. If damaged, replace control board using Control Board Kit, page 28. | p.23 |
| Motor runs and pump cycles, but pressure does not build up. | Intake valve or outlet valve is not seating properly. | Remove and clean inlet valves and outlet valves. Replace if necessary. See List of Kits, page 28. | p.24 |
| Motor runs and pump cycles, but pressure does not build up. | Pump packings are worn or damaged. | Check for leaking around pump. ProX7 and ProX9: Replace pump packings. See List of Kits, page 28. X5 and X7: Replace complete pump. See List of Kits, page 28. | p.24 |
| Prime/Spray Valve actuates automatically, relieving pressure through drain tube. | Pressure control switch has pinched wires or switch is worn. | Replace pressure control switch using Pressure Control Switch Kit, page 28. | p.24 |
| Prime/Spray Valve actuates automatically, relieving pressure through drain tube. | Water or paint entered pressure control switch or shorted control board. | Use Pressure Control Switch Kit, to replace switch. See List of Kits, page 28. | p.24 |
| Prime/Spray Valve actuates automatically, relieving pressure through drain tube. | Control board failed. | See Control Board Diagnostics, page 27. Replace damaged control board using Control Board Kit, page 28. | p.24 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.