PR70 and PR70v Integrated Heat
For controlling material temperature in heated tanks and hoses.

Assembly LC0252 Shown ti12577a

Supplied Manuals
Supplied Manuals 2 Warnings 3 Component Identification 4 Grounding 5 Installation 5
Assemblies with a Standard Display Module include manual 312393. Assemblies with an Advanced Display Module include manuals 312759 and 312760.
Connect Electrical Cord 5 Install Low Power Temperature Control Modules 6 Connect 3-wire Module Power 6 Adjust Rotary Switch 7 Setup 8
Cable Connections 8 Operation 10 Maintenance 10
Install Upgrade Token 10 Clean 10 Troubleshooting 11
Circuit Breaker 11 Diagnostic Information 11 Simplified Wiring Schematic 11 Wiring Schematic 12 Parts 14
Circuit Breakers 17 Technical Data 19
Dimensions 19 Graco Ohio Standard Warranty 20 Graco Ohio Information 20
Supplied Manuals

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.


AD
AC
AK
AB
AA
AG
AH
AJ
Key: AA Zone 1 AB Zone 2 AC Zone 3 AD Zone 4 AE Electrical Disconnect Switch AF Fan
AG Integrated Heat Power Inlet AH Integrated Heat Power Outlet
to Machine AJ CAN Connection Output to Machine AK Heat Control Box
Component Identification · Assembly LC0253 Shown

appropriate gauge wire for the machine amperage. See the following table.

This product must be grounded. In the event of an elec- trical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric cur- rent. This product is equipped with a chord having a grounding wire. A 3-blade grounding plug must be installed or the machine may be hard wired. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

The equipment must be grounded. Grounding reduces the risk of static and electric shock by provid- ing an escape wire for the electrical current due to static build up or in the event of a short circuit. Improper installation of the grounding plug is able to result in a risk of electric shock. The wire with insula- tion having an outer surface that is green with or with- out yellow stripes is the grounding wire.
Improper installation of the grounding plug is able to result in a risk of electric shock. The wire with insulation having an outer surface that is green with or without yel- low stripes is the grounding wire. Do not modify the plug provided; if it does not fit the outlet, have the proper out- let installed by a qualified electrician. Only connect the product to an outlet having the same configuration as the plug. Do not use an adapter with this product.
Connect Electrical Cord
Machine may be hard-wired or installed using a plug.

Improper wiring may cause electric shock or other serious injury if work is not performed properly. Have a qualified electrician perform any electrical work. Be sure your installation complies with all National, State and Local safety and fire codes.
Grounding · Install Plug

The low power temperature control modules are installed in the Heat Control box at the factory. If a low power temperature control module must be replaced, perform the following procedure.

Connecting the power must be performed by a quali- fied electrician. The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.

Remove Old Low Power Temperate Control Module
Install New Low Power Temperate Control Module

There is one breaker for each heated hose or heated tank. The lower number breakers are used for the heated tanks if installed. See FIG. 3. For example, if there are two heated tanks installed and two heated hoses, breakers #1 and #2 are used for the heated tanks and breakers #3 and #4 are used for the heated hoses. If there is one heated tank and one heated hose, then breaker #1 is used for the heated tank and breaker #2 is used for the heated hose. Each breaker has a dif- ferent rating so it is important that the correct breaker is used.
Set the rotary switch (S) to the specific selection accord- ing to the settings listed in the following table.
Low Power Temperature Control Module

The 3-wire module power is connected in the Heat Con- trol box at the factory. The power cord (118) for each low power temperature control module has a connector on one end and three power leads on the other. The three power leads must be connected to the appropriate breaker (114) and ground terminal (116).
F IG . 4
The modules must always be set to the zone num- ber shown on the label above the module.
The rotary switch setting must only be adjusted on new low power temperature control modules after installation.
The rotary switch setting indicates which zone number the low power temperature control module will control in the system. The low power temperature control module uses a 16-position rotary switch.
Installation · Rotary Switch Location

Cable Connections


1 Overtemperature Switch Connection 2 RTD Temperature Sensor Connection 3 Output Power Connection
4 DC Output Connection 5 Input Power Connection 6 CAN Connections 7 Base
The overtemperature switch connection (1), RTD tem- perature sensor connection (2), and output power connection (3) connect to the respective components of a temperature control option. The display module must be updated to specify which zone number is used with which temperature control option. See the PR70 and PR70v Operation manual referenced at the beginning of this manual for more information.
Setup · ti12356a ti12357a


The low power temperate control modules must be con- nected together using the female-female CAN cables (130) as shown in FIG. 6. Then they must be con- nected to the display module using the female-male CAN cable (113).
Setup

See the PR70 and PR70v Operation manual referenced at the beginning of this manual for operating instruc- tions.
Keep heat sink fins clean at all times. Wipe the fins clean with a dry cloth or clean them using compressed air.

Do not use conductive cleaning solvents on the low power temperature control modules.

There is no preferred orientation of token.

T
Operation · Heat Sink Fins

Circuit Breaker
If the circuit breaker is tripped, manually flip the breaker back to the “on” position. Find and correct the problem before continuing operation.

208-240V 50/60 Hz 1 phase
Circuit Breaker #4 Circuit Breaker #3
Low Power Temp Cont
Low Power Temp Cont
Low Power Temp Cont
Low Power Temp Cont


Troubleshooting


Troubleshooting


102 109 112 111
Heated hose and heated tank circuit breakers shown for reference only. See Circuit Breakers on page 17 for part numbers. 1
Parts

LC0253 Control Box, Heat, 4 Load,
LC0250 Control Box, Heat,
LC0251 Control Box, Heat,
LC0252 Control Box, Heat,
240V Qty 101 GUARD, fan, 80 mm x 80 mm 121560 1
102 SCREW, panhead machined 105676 10
103 NUT, lock, hex 105334 4 104 FAN, brushless, 80 x 80 x 25, 24 VDC 121556 1
105 CONNECTOR, straight, M8, 3-PIN, solder 121590 1
106 SWITCH, disconnect, 3-pole, 40A 121568 1
107 SHAFT, disconnect, elec- tric 121149 1
108 HANDLE, disconnect, electric 121148 1
109 FILTER, screen, fan, 80 mm x 80 mm 121559 1
110 SCREW 120916 2 111 FOOT, BUMPER 123698 4 112 SCREW 120885 4 113 CABLE, CAN, male / female, 0.4 m 121226 1
114 CONNECTOR, thru, M12, male / female 121612 1
115 BLOCK, end stop, termi- nal, tan, 35 mm RA 123384 2
116 BLOCK, terminal, spg, 4P, ground, 600V/20A 123686 (Qty 3)
123686 (Qty 4) 117 CORD, power, v-lock, C14/C13, 10A
121599 (Qty 5) 118 CORD, power, v-lock, 15P/C13, 10A 121598 (Qty 1)
121598 (Qty 4) 119 SCREW, socket head cap, 10-32 x 0.62, stain- less steel
120 PANEL, back, enclosure, 12 in. 121584 121584 1
PANEL, back, enclosure, 20 in. 121585 121585 1
121 ENCLOSURE, 12 x 12 x 6, 2 load 121563 121563 1
ENCLOSURE, 20 x 12 x 6, 4 load 121565 121565 1
122 GRIP, cord, 0.51 - 0.71, 3/4 121603 121603 1
GRIP, cord, 0.35 - 0.63, 3/4 121171 121171 1
123 SCREW, pan head machined, M5 - 0.8 x 12 mm
121725 2
124 MODULE, low power, Graco Control Architec- ture
125 MODULE, Graco Control Architecture, base

LC0253 Control Box, Heat, 4 Load,
LC0250 Control Box, Heat,
LC0251 Control Box, Heat,
LC0252 Control Box, Heat,
126 † COVER, heat box 15U672 15U672 1 127 NUT, hex 110911 110911 2 128 WASHER, plain #10 120907 120907 2 129 CORD, 10/3, 40A, SOOW, CU, 600V 065054 065054 12
CORD, 8/3, 30A, SOOW, CU, 600V 121158 121158 12
130 CABLE, CAN, 90 female / 90 female 121597 (Qty 1)
121597 (Qty 3) 131 RAIL, DIN 514014 (Qty 0.6)
514014 (Qty 0.83) 132 GASKET, enclosure, heat, Graco Control Architecture
514014 (Qty 0.83)
514014 (Qty 0.83)
133 CONNECTOR, bus bar, 2 phase, 4 poles 15U740 1
CONNECTOR, bus bar, 2 phase, 6 poles 15U741 1
CONNECTOR, bus bar, 2 phase, 8 poles 15U742 1
CONNECTOR, bus bar, 2 phase, 10 poles 15U743 1
134 TERMINAL 121648 2 135 CAP 121649 2 136 CONNECTOR, power, panel mount 121558 1
137 LABEL, zone1 15V283 1 138 LABEL, zone2 15V284 15V284 15V284 1 139 LABEL, zone3 15V285 15V285 1 140 LABEL, zone4 15V286 1 141 CIRCUIT, breaker, 2-pole, 10A, C type 121634 1
142† ENCLOSURE, Graco Control Architecture, door
277674 (Qty 4) 143 CABLE, CAN, M12 x M12, 5P, female / female, straight x right angle
121685 1
144 TERMINAL, ring, #8 AWG, 1/4 in. stud 123421 1
145 CIRCUIT, breaker, 63A, GFI 123687 1
146 BRACKET, disconnect, 40A 16C235 1
197† LABEL, electric shock XXXXX 1 198 PLATE, legend, serial number 293564 1
199† PLUG, retainer 123699 1
† Part not shown.
Replacement Danger and Warning labels, tags, and cards are available at no cost.

Heated Tank Assembly Circuit Breakers
See the PR70 and PR70v Repair - Parts manual refer- enced at the beginning of this manual to find the heated hose and heated tank assembly numbers for your sys- tem.
Tank Assembly Circuit Breaker LC0237
Heated Hose Circuit Breakers
Hose Package Circuit Breaker LC0881 121630 LC0882 121631 LC0883 121632 LC0884 121630 LC0885 121631 LC0886 121632 LC0887 121630 LC0888 121631 LC0889 121632 LC0890 121632 LC0891 121633 LC0190 121630 LC0191 121631 LC0192 121632 LC0193 121630 LC0194 121631 LC0195 121632 LC0196 121630 LC0197 121631 LC0198 121632 LC0199 121632 LC0200 121633 LC0201 121630 LC0202 121631 LC0203 121632 LC0204 121630 LC0205 121631 LC0206 121632 LC0207 121630 LC0208 121631 LC0209 121632 LC0210 121632 LC0211 121633
Parts · Installed Heated · Installed Heated

Parts

Electrical Power 208-240V 50/60 Hz, 1 phase for heat - 10 kW max.
(Qty 4) 2500W outputs Weight 30 lb (13.6 kg) - 1 and 2 Zone Models
50 lb (22.7 kg) - 3 and 4 Zone Models


1 and 2 Zone Assemblies
3 and 4 Zone Assemblies
in. (mm) A (height) 12 (305) 20 (508) B (width) 12 (305) 12 (305) C (depth) 6 (152) 6 (152)
in. (mm)
Technical Data · Assembly LC0253 Shown · Ref

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Toll Free: 1-800-746-1334 or Fax: 330-966-3006
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 312761
GRACO OHIO INC. 8400 PORT JACKSON AVE NW, NORTH CANTON, OH 44720
Copyright 2008, Graco Ohio Inc. is registered to I.S. EN ISO 9001
Rev 9/2009