306–993 Rev . D Supersedes Rev . B and PCN C First choice when quality counts. INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Hydra-Clean ) Pressure W ashers 42 bar , 4.
T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . .
W ARNING INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury , including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury .
4 306-993 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re - sult in a fire or explosion and serious injury . Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
5 306-993 Setup Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE OR EXPLOSION HAZARD on page 4. Although water generally provides a natural electrical ground, the following equipment must be grounded if the cleaning chemical are volatile.
Setup Connect Hoses and Mount Pump Connect hoses and pump as follows: NOTE: This pump is supplied with a bracket (D) which holds it to the side of a drum. If you want to install the pump on a wall, do not install the hanging bracket.
7 306-993 Setup D U B F M J R P KEY A Barbed Hose Stud B Suction Hose C Pump Intake housing D Bracket E Screw , Lockwasher , and Nut F Pump Runaway V alve G Air Line Lubricator H Pu.
8 306-993 Operation General Information The following instructions are for operation of the Monark 5:1 Ratio Hydra–Clean Pressure W ashers Model 205–985 and Model 207–860.
Operation W ARNING T o avoid serious injury , including fluid injection and splashing in the eyes or on the skin, never point the gun at yourself or anyone else. Before Using See Fig. 2. Prepare cleaning solution as instructed, observing all safety precautions.
10 306-993 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment always make sure to relieve the pressure .
11 306-993 Service General W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. See Parts illustration for referenced items. Shut of f the air supply to the pump and relieve the pressure .
12 306-993 Parts 0676 8 17 (MODEL 205–985) 11 4 13 2 18 15 21 19 14 16 20 3 5 12 6 Model 205–985 Monark Hydra-Clean and Model 207–860 Monark Hydra-Clean 1 7 8 8 9 10 (MODEL 207–860) 22 23.
13 306-993 Parts Model 207–860 Monark Hydra-Clean Ref No. Part No. Description Qty . 1 214–847 AIR LINE LUBRICA TOR 1 2* 206–300 FIL TER, fluid intake 1 3 224–343 5:1 Ratio Monark Pump See man.
14 306-993 Accessories Stainless Steel Spray Tips AIR SUPPL Y T O PUMP TIP NO. ORIFICE SIZE SPRA Y ANGLE 70 PSI (4.8 bar , 0.48 MPa) 100 psi (7 bar , 0.7 MPa) NO . SIZE ANGLE GPM CFM WP GPM CFM WP 164–435 .043 40 160–964 .043 25 164–434 .052 25 164–436 .
15 306-993 Dimensions 24.5” (622 mm) 1 1.75” (298 mm) T echnical Data Air pressure range 40 to 120 psi (2.8 to 8.4 bar , .28 to .84 MPa) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air volume requirements 8.
16 306-993 Graco Standard W arranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
An important point after buying a device Graco Inc. 207-860 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco Inc. 207-860 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco Inc. 207-860 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco Inc. 207-860 you will learn all the available features of the product, as well as information on its operation. The information that you get Graco Inc. 207-860 will certainly help you make a decision on the purchase.
If you already are a holder of Graco Inc. 207-860, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco Inc. 207-860.
However, one of the most important roles played by the user manual is to help in solving problems with Graco Inc. 207-860. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco Inc. 207-860 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center