0681 1 Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001 Hydra–Clean r 4043, 16 HP Engine Hydra–Clean r 4043 Pressure W asher P/N 800707, Series B 4000 psi (27.
308532 2 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Component Identification and Function 4 . . . . . . . . . . . . Setup 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
308532 3 W ARNING HAZARDOUS FLUIDS Improper handling of hazardous fluids can cause serious injury , even death, due to splashing in eyes, ingestion or bodily contamination. D Know specific hazards of fluid being used. D Store hazardous fluids in approved containers.
308532 4 Component Identification and Function 06812 0681 1 T ypical Installation – Pressure W asher Fig. 1 F M E G K A B D C H J L A Engine 16 horsepower , operates pump assembly B Pump Assembly Pressurizes fluid to be sprayed through spray gun C Filter Screens out debris and other material between supply connection and pump.
308532 5 Setup Check for Shipping Damage Check the unit for any damage that may have occurred in shipping. Notify the carrier immediately if there is any damage. Set Up Charge the battery . Be sure the battery connections are correct and secure. Connect the fuel line to the engine using the quick coupler provided.
308532 6 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD System pressure must be manually relieved to prevent system from starting or spraying accidentally . Fluid under high pressure can be injected through skin and cause serious injury .
308532 7 Operation CAUTION Pressure washer is equipped with a thermal relief valve. If pressure washer is operated without spraying for an extended period (approximately 10 minutes) the valve will expel hot water . Do not operate pressure washer with inlet water screen removed.
308532 8 Operation Installing and Changing Spray T ips W ARNING T o reduce risk of serious bodily injury , including fluid injection or splashing in eyes or onto skin, use extreme caution when changing spray tips. always follow procedure below . 1. Follow the Pressure Relief Procedure .
308532 9 Shutdown, Flushing, and Storage CAUTION Do not expose pressure washer to freezing tem- peratures or allow water to freeze in pressure washer components. If water freezes in the pres- sure washer , thaw it in a warm room before you try to start it.
308532 10 T roubleshooting W ARNING T o reduce risk of serious injury , including fluid injection and splashing in eyes, or on skin, always follow Pres- sure Relief Procedure on page 6 before proceeding. Problem Cause Solution Engine will not start or is hard to start No gasoline in fuel tank or carburetor .
308532 11 Pump Service Servicing the V alves 1. Remove the hex valve plug. 2. Examine the o–ring under the plug for cuts or distortion and replace if worn. Lubricate new o–ring before installing. 3. Grasp valve retainer by tab at the top with pliers and remove from valve chamber .
308532 12 Pump Service Servicing the Seals and V–Packings Disassembly: 1. Remove the manifold as described. 2. With crankcase side of manifold facing up, unscrew the seal case from the manifold using a special key wrench. 3. Remove o–ring from seal case.
308532 13 Notes.
308532 14 Pressure W asher – Parts + – – 06810 + 43 42 41 44a, 44h 45 63 47 24 2 5 12 2 25 17 13 14 16 5 31 40 33 34 35 36 29 2 28 21a 19 18 51 30 46 1 2 48 50 49 4 6 7 62 37b 52 61 9 58 57 56 5.
308532 15 Pressure W asher – Parts Model 800707, Series B Ref. No. Part N o. Description Qty . 1 108868 CLAMP , wir e 1 2 100214 W ASHER, lock 5/16 4 3 803889 BEL T , drive 2 4 803943 SHEA VE, engin.
308532 16 Pressure W asher – Parts 7544A 80 89 81 82 83 84 85 86 87 88 90 91 92 97 104 109* 11 0 111 11 4 43 Hydra–Clean 4043 Pressure W asher (Sheet 2 of 2) 2 120 *Note: Chemical Injector Repair .
308532 17 Notes.
308532 18 Pump Assembly – Parts 04608 1 2 3 9 4 12 13 14 15 17 16 18 19 20 21 22 23 24 25 26 27 28 29 31 30 32 33 22 a 35 12 39 40 14 41 15 4e 9a 42 53 51 52 54 34 c d 9a 9b a b c d e a b c e f g d .
308532 19 Pump Assembly – Parts Model 803508, Series A Ref. No. Part N o. Description Qty . Ref. No. Part No. Description Qty . 1 803504 MANIFOLD 1 2 801468 SCREW , cap, hex hd 8 3 801469 W ASHER, l.
308532 20 Accessories Downstream Chemical Injector Kit 804387 For injecting harsh cleaning chemicals downstream from the pump. 800649 is stainless steel construction. Upstream Chemical Injector Kit 800257 For injecting mild cleaning chemicals upstream into the pump.
308532 21 T echnical Data Model 800707 Engine (4 cycle, air–cooled) 16 HP Briggs & Stratton OHV Battery 12 V olt, 30 AMP 250 CCA Gasoline T ank Capacity 6 Gallon (23 Liter) W ater Pump Maximum Working Pressure 4000 psi (276 bar) W ater Pump Maximum Flow 4.
308532 22 Graco W arranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
An important point after buying a device Graco HYDRACLEANR 4043 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco HYDRACLEANR 4043 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco HYDRACLEANR 4043 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco HYDRACLEANR 4043 you will learn all the available features of the product, as well as information on its operation. The information that you get Graco HYDRACLEANR 4043 will certainly help you make a decision on the purchase.
If you already are a holder of Graco HYDRACLEANR 4043, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco HYDRACLEANR 4043.
However, one of the most important roles played by the user manual is to help in solving problems with Graco HYDRACLEANR 4043. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco HYDRACLEANR 4043 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center