INSTRUCTIONS-P AR TS LIST 308–534 Rev A This manual contains IMPORT ANT W ARNINGS and INSTRUCTIONS READ AND RET AIN FOR REFERENCE HYDRA-CLEAN 735, 740, 1035, 1040 Pressure W ashers Model 800–9.
W ARNING HIGH PRESSURE SPRA Y CAN CAUSE SERIOUS INJUR Y . FOR PROFESSIONAL USE ONL Y . OBSER VE ALL W ARNINGS. Read and understand all instruction manuals before operating equipment. FLUID INJECTION HAZARD General Safety This pressure washer generates very high fluid pressure.
3 GROUNDING INSTRUCTIONS This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This equipment is equipped with a cord having an equipment–grounding conductor and a grounding plug.
4 HOSE SAFETY High pressure fluid in the hoses can be very dangerous. If the hose develops a leak, split or rupture due to any kind of wear , damage or misuse, the high pressure spray emitted from it can cause a fluid injection injury or other serious bodily injury or property damage.
5 INST ALLA TION Figure 1 PUMP DIP - STICK HIGH PRESSURE HOSE CONNECTION 2 x 1/2” NPT(f) W A TER CONNECTION 2 x 1” NPT(f) PUMP OIL LEVEL INDICA TOR WINDOW W ater supply tank, gun & wand assem - bly , hose assembly and motor starter are not included.
6 6ą308-534 ST ARTUP Use this procedure whenever starting the pressure washer to help insure that the unit is ready to operate and starting is done safely . 1. Check the oil level. Pump: Add SAE 20 or 30 weight non–detergent oil as necessary . 2. T urn on the water supply .
7 308-534ą7 T rigger Safety Latch W ARNING T o reduce the risk of serious bodily injury , including fluid injection, splashing in the eyes or on the skin, AL WA YS engage the trigger safety latch whenever spraying stops, even for a moment.
8 SHUTDOWN, FLUSHING AND STORAGE W ARNING PRESSURE RELIEF PROCEDURE T o reduce the risk of serious bodily injury , including fluid injection and splashing in the eyes, or o.
9 308-534ą9 TROUBLESHOOTING CHART W ARNING To reduce the risk of serious bodily injury , including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, always follow the Pressure Relief Procedure W arning before proceeding.
10 10ą308-534 PUMP SER VICE W ARNING T o reduce the risk of serious bodily injury , including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, always follow the Pressure Relief Procedure W arning before proceeding. NOTE: The following metric wrenches are needed: M10, M13 and M30.
11 308-534ą11 Servicing the V–Packings NOTE: There are two types of packing kits: one is packings only , the other includes the packings, rings and retainers. 1. Remove the manifold as outlined in the Pumping Section. 2. Carefully pull the packing retainer from the manifold.
12 12ą308-534 P ARTS DRA WING 800–906 Hydra–Clean 735 Pressure W asher 800–907 Hydra–Clean 1035 Pressure W asher 2 5 4 3 23 12 11 15 14 13 33 37 36 35 34 31 9 10 32 9 29 16 17 21 22 2.
13 308-534ą13 P ARTS LIST 800–906 Hydra–Clean 735 Pressure W asher 800–907 Hydra–Clean 1035 Pressure W asher REF P ART NO. NO. DESCRIPTION QTY 1 800–643 CHASSIS 1 2 803–788 BEL T GUARD 1 3 801–940 SCREW , Cap, hex hd.
14 14ą308-534 P ARTS DRA WING 800–908 Hydra–Clean 740 Pressure W asher 800–909 Hydra–Clean 1040 Pressure W asher 2 5 4 3 23 12 11 15 14 13 33 37 36 35 34 31 9 10 32 9 29 16 17 21 22 2.
15 308-534ą15 P ARTS LIST 800–908 Hydra–Clean 740 Pressure W asher 800–909 Hydra–Clean 1040 Pressure W asher REF P ART NO. NO. DESCRIPTION QTY 1 800–643 CHASSIS 1 2 803–788 BEL T GUARD 1 3 801–940 SCREW , Cap, hex hd.
16 P ARTS DRA WING 803–815 Pump Assembly , 35 GPM 803–816 Pump Assembly , 40 GPM 22 25 21 20 30 29 34 31 33 61 38 32 41 43 54 55 56 57 58 62 56 57 45 47 51 52 8 9 10.
17 P ARTS LIST 803–815 Pump Assembly , 35 GPM 803–816 Pump Assembly , 40 GPM REF P ART NO. NO. DESCRIPTION QTY 1 803–659 SCREW , Cap, socket hd.
18 18ą308-534 ACCESSORIES (Must be purchased separately) DOWNSTREAM C HEMICAL INJECT O R K IT 800–117 BRAS S U P T O 5 . 5 G PM (21 LPM) 800–42 5 B RAS S 5 .6 T O 1 0. 8 G PM (21 T O 4 1 L PM ) 800–64 9 S TA I N L E S S S TEE L U P T O 5 . 5 G PM (21 LPM) For injecting harsh cleaning chemicals downstream from the p ump.
19 TECHNICAL DA T A Model 800–909 Model 800–908 Model 800–907 Model 800–906 Motor (T otally Enclosed Fan Cooled) Electrical Service W ater Pump Maximum Working P.
20 THE GRACO W ARRANTY W ARRANTY AND DISCLAIMERS Graco warrants all equipment manufactured by it and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
An important point after buying a device Graco Hydra-Clean 1035 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco Hydra-Clean 1035 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco Hydra-Clean 1035 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco Hydra-Clean 1035 you will learn all the available features of the product, as well as information on its operation. The information that you get Graco Hydra-Clean 1035 will certainly help you make a decision on the purchase.
If you already are a holder of Graco Hydra-Clean 1035, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco Hydra-Clean 1035.
However, one of the most important roles played by the user manual is to help in solving problems with Graco Hydra-Clean 1035. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco Hydra-Clean 1035 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center