EN
Graco logo
Official user manual

Graco H50

52 pages·3.7 MB·Paint Sprayer·PDF·ENDEFRITNLJA
Graco H50
Table of Contents 55 sections Systems · Models · Supplied Manuals · Related Manuals · … ShowHide
Page 1 of the Graco H50 user manual — EN
Page 1 · click to enlarge
Page 1

Operation

Graco H50 — Operation diagram (page 1)
Fig. 1 · Operation

EN

Hydraulic, Heated, Plural Component Proportioner For spraying polyurethane foam and polyurea coatings. For professional use only. Not approved for use in European explosive atmosphere locations.

Graco H50 — EN diagram (page 1)
Fig. 2

See page 3 for model information, including maximum working pressure and approvals.

Model H-40 Shown · T9830a

Page 3 of the Graco H50 user manual — Systems
Page 3 · click to enlarge
Page 3

Systems

PartMaximum Fluid Working Pressure psi (MPa, bar)Proportioner (see page 3)Heated HoseGunMix Chamber Kit 50 ft (15 m)10 ft (3 m)ModelPart ★AP34002000 (13.8, 138)★253400246678246050Fusion Air Purge246101AR5252 AP34012000 (13.8, 138)253401246678246050Fusion Air Purge246101AR5252 AP34022000 (13.8, 138)253402246678246050Fusion Air Purge246101AR5252 ★AP34033500 (24.1, 241)★253403246679246055Fusion Air Purge246101AR4242 AP34043500 (24.1, 241)253404246679246055Fusion Air Purge246101AR4242 AP34053500 (24.1, 241)253405246679246055Fusion Air Purge246101AR4242 AP34072000 (13.8, 138)253407246678246050Fusion Air Purge246101AR5252 AP34082000 (13.8, 138)253408246678246050Fusion Air Purge246101AR5252 ★AP37251700 (11.7, 117)★253725246678246050Fusion Air Purge246101AR5252 AP37262000 (13.8, 138)253726246678246050Fusion Air Purge246101AR5252 AP37272000 (13.8, 138)253727246678246050Fusion Air Purge246101AR5252 AP54002000 (13.8, 138)255400246678246050Fusion Air Purge246101AR5252 AP54012000 (13.8, 138)255401246678246050Fusion Air Purge246101AR5252 AP54022000 (13.8, 138)255402246678246050Fusion Air Purge246101AR5252 AP54033500 (24.1, 241)255403246679246055Fusion Air Purge246100AR2929 AP54043500 (24.1, 241)255404246679246055Fusion Air Purge246100AR2929 AP54053500 (24.1, 241)255405246679246055Fusion Air Purge246100AR2929 AP54062000 (13.8, 138)255406246678246050Fusion Air Purge246101AR5252 AP54072000 (13.8, 138)255407246678246050Fusion Air Purge246101AR5252 AP54082000 (13.8, 138)255408246678246050Fusion Air Purge246101AR5252 AP65052000 (13.8, 138)256505246678246050Fusion Air Purge246101AR5252 AP65062000 (13.8, 138)256506246678246050Fusion Air Purge246101AR5252 CS54002000 (13.8, 138)255400246678246050Fusion CSCS02RD CS54012000 (13.8, 138)255401246678246050Fusion CSCS02RD CS54022000 (13.8, 138)255402246678246050Fusion CSCS02RD CS54062000 (13.8, 138)255406246678246050Fusion CSCS02RD CS54072000 (13.8, 138)255407246678246050Fusion CSCS02RD CS54082000 (13.8, 138)255408246678246050Fusion CSCS02RD

★CE approval does not apply.

Systems

Page 4 of the Graco H50 user manual — Systems Continued
Page 4 · click to enlarge
Page 4

Systems Continued

PartMaximum Fluid Working Pressure psi (MPa, bar)Proportioner (see page 3)Heated HoseGun 50 ft (15 m)10 ft (3 m)ModelPart ★P234002000 (13.8, 138)★253400246678246050Probler P2GCP2R2 P234012000 (13.8, 138)253401246678246050Probler P2GCP2R2 P234022000 (13.8, 138)253402246678246050Probler P2GCP2R2 ★P234033500 (24.1, 241)★253403246679246055Probler P2GCP2R1 P234043500 (24.1, 241)253404246679246055Probler P2GCP2R1 P234053500 (24.1, 241)253405246679246055Probler P2GCP2R1 P234072000 (13.8, 138)253407246678246050Probler P2GCP2R2 P234082000 (13.8, 138)253408246678246050Probler P2GCP2R2 ★P237251700 (11.7, 117)★253725246678246050Probler P2GCP2R2 P237262000 (13.8, 138)253726246678246050Probler P2GCP2R2 P237272000 (13.8, 138)253727246678246050Probler P2GCP2R2 P254002000 (13.8, 138)255400246678246050Probler P2GCP2R2 P254012000 (13.8, 138)255401246678246050Probler P2GCP2R2 P254022000 (13.8, 138)255402246678246050Probler P2GCP2R2 P254033500 (24.1, 241)255403246679246055Probler P2GCP2R0 P254043500 (24.1, 241)255404246679246055Probler P2GCP2R0 P254053500 (24.1, 241)255405246679246055Probler P2GCP2R0 P254062000 (13.8, 138)255406246678246050Probler P2GCP2R2 P254072000 (13.8, 138)255407246678246050Probler P2GCP2R2 P254082000 (13.8, 138)255408246678246050Probler P2GCP2R2 P265052000 (13.8, 138)256505246678246050Probler P2GCP2R2 P265062000 (13.8, 138)256506246678246050Probler P2GCP2R2

★CE approval does not apply.

Systems

Page 5 of the Graco H50 user manual — H-50 SERIES
Page 5 · click to enlarge
Page 5

Models

H-25 SERIES

Part, SeriesFull Load Peak Amps* Per PhaseVoltage (phase)System Watts†Primary Heater WattsMax Flow Rate◆ lb/min (kg/min)Approximate Output per Cycle (A+B) gal. (liter)Hydraulic Pressure RatioMaximum Fluid Working Pressure psi (MPa, bar) 255400, F69230V (1)15,9608,00022 (10)0.063 (0.24)1.91:12000 (13.8, 138) 255401, F46230V (3)15,9608,00022 (10)0.063 (0.24)1.91:12000 (13.8, 138) 255402, F35400V (3)15,9608,00022 (10)0.063 (0.24)1.91:12000 (13.8, 138) 255406, F100230V (1)23,26015,30022 (10)0.063 (0.24)1.91:12000 (13.8, 138) 255407, F59230V (3)23,26015,30022 (10)0.063 (0.24)1.91:12000 (13.8, 138) 255408, F35400V (3)23,26015,30022 (10)0.063 (0.24)1.91:12000 (13.8, 138)

H-40 SERIES

Part, SeriesFull Load Peak Amps* Per PhaseVoltage (phase)System Watts†Primary Heater WattsMax Flow Rate◆ lb/min (kg/min)Approximate Output per Cycle (A+B) gal. (liter)Hydraulic Pressure RatioMaximum Fluid Working Pressure psi (MPa, bar) ★253400, E100230V (1)23,10012,00045 (20)0.063 (0.24)1.91:12000 (13.8, 138) 253401, E71230V (3)26,60015,30045 (20)0.063 (0.24)1.91:12000 (13.8, 138) 253402, E41400V (3)26,60015,30045 (20)0.063 (0.24)1.91:12000 (13.8, 138) 253407, E95230V (3)31,70020,40045 (20)0.063 (0.24)1.91:12000 (13.8, 138) 253408, E52400V (3)31,70020,40045 (20)0.063 (0.24)1.91:12000 (13.8, 138)

H-50 SERIES

Part, SeriesFull Load Peak Amps* Per PhaseVoltage (phase)System Watts†Primary Heater WattsMax Flow Rate◆ lb/min (kg/min)Approximate Output per Cycle (A+B) gal. (liter)Hydraulic Pressure RatioMaximum Fluid Working Pressure psi (MPa, bar) ★253725, E100230V (1)23,10012,00052 (24)0.073 (0.28)1.64:11700 (11.7, 117) 253726, E71230V (3)26,60015,30052 (24)0.073 (0.28)1.64:12000 (13.8, 138) 253727, E41400V (3)26,60015,30052 (24)0.073 (0.28)1.64:12000 (13.8, 138) 256505, E95230V (3)31,70020,40052 (24)0.073 (0.28)1.64:12000 (13.8, 138) 256506, E52400V (3)31,70020,40052 (24)0.073 (0.28)1.64:12000 (13.8, 138)

Models

Page 6 of the Graco H50 user manual — Approvals:
Page 6 · click to enlarge
Page 6

H-XP2 SERIES

Part, SerieFull Load Peak Amps* s Per PhaseVoltage (phase)System Watts†Primary Heater WattsMax Flow Rate◆ gpm (lpm)Approximate Output per Cycle (A+B) gal. (liter)Hydraulic Pressure RatioMaximum Fluid Working Pressure psi (MPa, bar) 255403,F 100230V (1)23,26015,3001.5 (5.7)0.042 (0.16)2.79:13500 (24.1, 241) 255404,F 59230V (3)23,26015,3001.5 (5.7)0.042 (0.16)2.79:13500 (24.1, 241) 255405,F 35400V (3)23,26015,3001.5 (5.7)0.042 (0.16)2.79:13500 (24.1, 241)
Graco H50 — H-XP2 SERIES diagram (page 6)
Fig. 3

H-XP3 SERIES

Part, SerieFull Load Peak Amps* s Per PhaseVoltage (phase)System Watts†Primary Heater WattsMax Flow Rate◆ gpm (lpm)Approximate Output per Cycle (A+B) gal. (liter)Hydraulic Pressure RatioMaximum Fluid Working Pressure psi (MPa, bar) ★253403,E 100230V (1)23,10012,0002.8 (10.6)0.042 (0.16)2.79:13500 (24.1, 241) 253404,E 95230V (3)31,70020,4002.8 (10.6)0.042 (0.16)2.79:13500 (24.1, 241) 253405,E 52400V (3)31,70020,4002.8 (10.6)0.042 (0.16)2.79:13500 (24.1, 241)
Graco H50 — H-XP3 SERIES diagram (page 6)
Fig. 4

* Full load amps with all devices operating at maximum capabilities. Fuse requirements at vari- ous flow rates and mix chamber sizes may be less.

† Total system watts, based on maximum hose length for each unit:

  • Parts 255400 through 255408, 310 ft (94.6 m) maximum heated hose length, including whip hose.
  • Parts 253400 through 253408, 253725 through 253727, 256505, and 256506, 410 ft (125 m) maximum heated hose length, including whip hose.

◆ Maximum flow rate given for 60 Hz operation. For 50 Hz operation, maximum flow rate is 5/6 of

60 Hz maximum flow.

★CE approval does not apply.

Approvals:

Graco H50 — Approvals: diagram (page 6)
Fig. 5 · Approvals:

Models

Page 7 of the Graco H50 user manual — Supplied Manuals
Page 7 · click to enlarge
Page 7

Supplied Manuals

The following manuals are shipped with the Reactor™ Proportioner. Refer to these manu- als for detailed equipment information.

Order Part 15M334 for a compact disk of Reactor manuals translated in several lan- guages.

Manuals are also available at www.graco.com

Reactor Hydraulic Proportioner PartDescription 312063Reactor Hydraulic Proportioner, Repair-Parts Manual (English) Reactor Electrical Diagrams PartDescription 312064Reactor Hydraulic Proportioner, Electrical Diagrams (English) Proportioning Pump PartDescription 312068Proportioning Pump Repair-Parts Manual (English)

Supplied Manuals

Page 8 of the Graco H50 user manual — Related Manuals
Page 8 · click to enlarge
Page 8

Related Manuals

The following manuals are for accessories used with the Reactor™.

Circulation Kit PartDescription 309818Instruction-Parts Manual (English) Circulation Valve Kit PartDescription 312070Instruction-Parts Manual (English) Data Reporting Kit PartDescription 309867Instruction-Parts Manual (English) Rupture Disk Assembly Kit PartDescription 309969Instruction-Parts Manual (English) Proportioning Pump Repair Kits PartDescription 312071Seal Kits Instruction-Parts Manual (English)

Order Part 15M334 for a compact disk of Reactor manuals translated in several lan- guages.

Feed Pump Kits PartDescription 309815Instruction-Parts Manual (English) Air Supply Kit PartDescription 309827Instruction-Parts Manual (English) for Feed Pump Air Supply Kit Circulation and Return Tube Kits PartDescription 309852Instruction-Parts Manual (English) Heated Hose PartDescription 309572Instruction-Parts Manual (English)

Related Manuals

Page 9 of the Graco H50 user manual — Warnings
Page 9 · click to enlarge
Page 9

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equip- ment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

WARNING ELECTRIC SHOCK HAZARD This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock. • Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment. • Connect only to grounded power source. • All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations. TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDSs to know the specific hazards of the fluids you are using. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. • Always wear chemically impermeable gloves when spraying, dispensing, or cleaning equipment. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: • Protective eyewear • Clothing and respirator as recommended by the fluid and solvent manufacturer • Gloves • Hearing protection
Page 10 of the Graco H50 user manual — Warnings
Page 10 · click to enlarge
Page 10
WARNING SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Engage trigger lock when not spraying. • Do not point gun at anyone or at any part of the body. • Do not put your hand over the spray tip. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing equipment. • Tighten all fluid connections before operating the equipment. • Check hoses and couplings daily. Replace worn or damaged parts immediately. FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. • Ground all equipment in the work area. See Grounding instructions. • Use only grounded hoses. • Hold gun firmly to side of grounded pail when triggering into pail. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. • Keep a working fire extinguisher in the work area. THERMAL EXPANSION HAZARD Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure due to the thermal expansion. Over-pressurization can result in equipment rupture and serious injury. • Open a valve to relieve the fluid expansion during heating. • Replace hoses proactively at regular intervals based on your operating conditions.
Page 11 of the Graco H50 user manual — Warnings
Page 11 · click to enlarge
Page 11
WARNING PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage. • Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents. • Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for compatibility. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • This equipment is for professional use only. • Do not leave the work are while the equipment is energized or under pressure. Turn off all equipment and follow the Pressure Relief Procedure in this manual when the equipment is not in use. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply. BURN HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely.
Page 12 of the Graco H50 user manual — Material Self-ignition
Page 12 · click to enlarge
Page 12

Important Two-Component Material Information

Isocyanate Conditions

Keep Components A and B Separate

Spraying or dispensing materials containing isocyanates creates potentially harmful mists, vapors, and atomized particulates.

Cross-contamination can result in cured material in fluid lines which could cause seri- ous injury or damage equipment. To prevent cross-contamination of the equipment’s wet- ted parts, never interchange component A (isocyanate) and component B (resin) parts.

Read material manufacturer’s warnings and material MSDS to know specific hazards and precautions related to isocyanates.

Prevent inhalation of isocyanate mists, vapors, and atomized particulates by pro- viding sufficient ventilation in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for every- one in the work area.

Moisture Sensitivity of Isocyanates

Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce perfor- mance and the life of all wetted parts.

To prevent contact with isocyanates, appro- priate personal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area.

The amount of film formation and rate of crystallization varies depending on the blend of ISO, the humidity, and the tem- perature.

Material Self-ignition

To prevent exposing ISO to moisture:

Some materials may become self-igniting if applied too thickly. Read material manufac- turer’s warnings and material MSDS.

  • Always use a sealed container with a desiccant dryer in the vent, or a nitrogen atmosphere. Never store ISO in an open container.
  • Keep the ISO lube pump reservoir (if installed) filled with Graco Throat Seal Liquid (TSL), Part 206995. The lubricant creates a barrier between the ISO and the atmosphere.
Page 13 of the Graco H50 user manual — Foam Resins with 245 fa Blowing Agents
Page 13 · click to enlarge
Page 13
  • Use moisture-proof hoses specifically designed for ISO, such as those supplied with your system.
  • Never use reclaimed solvents, which may contain moisture. Always keep solvent containers closed when not in use.
  • Never use solvent on one side if it has been contaminated from the other side.
  • Always lubricate threaded parts with ISO pump oil or grease when reassembling.

Changing Materials

  • When changing materials, flush the equipment multiple times to ensure it is thoroughly clean.
  • Always clean the fluid inlet strainers after flushing.
  • Check with your material manufacturer for chemical compatibility.
  • Most materials use ISO on the A side, but some use ISO on the B side.

Foam Resins with 245 fa Blowing Agents

  • Epoxies often have amines on the B (hardener) side. Polyureas often have amines on the B (resin) side.

Some foam blowing agents will froth at tem- peratures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system.

Page 14 of the Graco H50 user manual — F IG . 1: Typical Installation, with circulation
Page 14 · click to enlarge
Page 14

Typical Installation, with circulation

Typical Installation, with circulation

Key for F IG . 1

A Reactor Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Fusion Spray Gun F Gun Air Supply Hose

G Feed Pump Air Supply Lines J Fluid Supply Lines K Feed Pumps L Agitator M Desiccant Dryer P Gun Fluid Manifold (part of gun) R Circulation Lines

Graco H50 — Key for F IG . 1 diagram (page 14)
Fig. 6 · Key for F IG . 1

* Shown exposed for clarity. Wrap with tape during operation.

F IG . 1: Typical Installation, with circulation

Page 15 of the Graco H50 user manual — B
Page 15 · click to enlarge
Page 15

Typical Installation, without circulation

Typical Installation, without circulation

Key for F IG . 2

A Reactor Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Fusion Spray Gun F Gun Air Supply Hose G Feed Pump Air Supply Lines

H Waste Containers J Fluid Supply Lines K Feed Pumps L Agitator M Desiccant Dryer N Bleed Lines P Gun Fluid Manifold (part of gun)

B Side Supply Detail

A Side Supply Detail

Graco H50 — B Side Supply Detail diagram (page 15)
Fig. 7 · B Side Supply Detail
Graco H50 — B Side Supply Detail diagram (page 15)
Fig. 8 · B Side Supply Detail

K M

K

Graco H50 — K M diagram (page 15)
Fig. 9

G

L G

J

A

J

F

N H

D

E

P

C*

* Shown exposed for clarity. Wrap with tape during operation.

B

F IG . 2: Typical Installation, without circulation

Page 16 of the Graco H50 user manual — Key for F IG . 3
Page 16 · click to enlarge
Page 16

Component Identification

Key for F IG . 3

BA Component A Pressure Relief Outlet BB Component B Pressure Relief Outlet EC Heated Hose Electrical Connector EM Electric Motor, Fan, and Belt Drive (behind shroud) FA Component A Fluid Manifold Inlet (on left side of manifold

block) FB Component B Fluid Manifold Inlet FH Fluid Heater (behind shroud) FM Reactor Fluid Manifold FP Feed Inlet Pressure Gauge FS Feed Inlet Strainer FT Feed Inlet Temperature Gauge FV Fluid Inlet Valve (B side shown) GA Component A Outlet Pressure Gauge GB Component B Outlet Pressure Gauge HA Component A Hose Connection HB Component B Hose Connection HC Hydraulic Pressure Control HP Hydraulic Pressure Gauge LR ISO Lube Pump Reservoir MC Motor Control Display MP Main Power Switch OP Overpressure Rupture Disk Assembly (on rear of A and B

pumps) PA Component A Pump PB Component B Pump RS Red Stop Button SA Component A PRESSURE RELIEF/SPRAY Valve SB Component B PRESSURE RELIEF/SPRAY Valve SC Fluid Temperature Sensor Cable SN Serial Number Plate (one inside cabinet, one on right side

of cabinet) SR Electrical Cord Strain Relief TA Component A Pressure Transducer (behind gauge GA) TB Component B Pressure Transducer (behind gauge GB) TC Temperature Control Display TD Oil Cooler

Component Identification

Page 17 of the Graco H50 user manual — BA
Page 17 · click to enlarge
Page 17
Graco H50 — Component Identification diagram (page 17)
Fig. 10 · Component Identification

FH

PA

OP

FT

FP

PB

FV

Detail of Reactor Fluid Manifold

(shroud removed for clarity)

SA

TA

GA GB

Graco H50 — FH diagram (page 17)
Fig. 11

Detail of Serial No. Plate (inside cabinet)

FA

Graco H50 — Detail of Serial No. Plate (inside cabinet) diagram (page 17)
Fig. 12 · Detail of Serial No. Plate (inside cabinet)

BA

FB

HB

SN

F IG . 3: Component Identification (H40 15.3 kW Model Shown)

Component Identification

Page 18 of the Graco H50 user manual — F IG . 4. Temperature Controls and Indicators
Page 18 · click to enlarge
Page 18

Temperature Controls and Indicators

Temperature Controls and Indicators

Graco H50 — Temperature Controls and Indicators diagram (page 18)
Fig. 13 · Temperature Controls and Indicators
Graco H50 — Temperature Controls and Indicators diagram (page 18)
Fig. 14 · Temperature Controls and Indicators

Zone A Arrow Keys

Heater A On/Off Key

Zone B Arrow Keys

Heater B On/Off Key

Hose Zone Arrow Keys

Hose Heater On/Off Key

F IG . 4. Temperature Controls and Indicators

Main Power Switch

Red Stop Button

Located on right side of unit, page 17. Turns

Located between temperature control panel and motor control panel, page 17. Press

Reactor power ON and OFF .

to shut off motor and heater zones

Does not turn heater zones or pumps on.

only. Use main power switch to shut off all power to unit.

Show 6 more labels / short text on this page
Heater Power Indicators · Heater Displays · Actual Temperature · Temperature Scale Keys · Key · Target Temperature Key
Page 19 of the Graco H50 user manual — ° F ° C
Page 19 · click to enlarge
Page 19

Temperature Controls and Indicators

Actual Temperature Key/LED

Heater Zone On/Off Keys/LEDs

Press to display actual temperature.

Press to turn heater zones on and off.

Also clears heater zone diagnostic codes, see page 42.

Press and hold to display electrical cur-

rent.

LEDs flash when heater zones are on. The duration of each flash shows the extent that the heater is turned on.

Target Temperature Key/LED

Press to display target temperature.

Temperature Arrow Keys

Press and hold to display heater control

Press , then press or to

circuit board temperature.

adjust temperature settings in 1 degree incre- ments.

Temperature Scale Keys/LEDs

Temperature Displays

Show actual temperature or target tempera- ture of heater zones, depending on selected mode. Defaults to actual at startup. Range is 32-190°F (0-88°C) for A and B, 32-180°F (0-82°C) for hose.

Press or to change temperature

° F ° C

scale.

Page 20 of the Graco H50 user manual — CB5
Page 20 · click to enlarge
Page 20

Temperature Controls and Indicators

Circuit Breakers

* Depending on model.

Graco H50 — Circuit Breakers diagram (page 20)
Fig. 15 · Circuit Breakers

Located inside Reactor cabinet.

Ref. Size Component

CB1

CB1 50 A Hose/Transformer Secondary

CB2

CB2 40 A Transformer Primary

CB3 25, 40, or 50 A* Heater A

CB5

For wiring and cabling, see repair manual 312063.

CB4 25, 40, or 50 A* Heater B

CB5 20 or 30 A* Motor/Pumps

ti9884a CB3 CB4

Page 21 of the Graco H50 user manual — Pressure Key/LED
Page 21 · click to enlarge
Page 21

Motor Controls and Indicators

Motor Controls and Indicators

Graco H50 — Motor Controls and Indicators diagram (page 21)
Fig. 16 · Motor Controls and Indicators
Graco H50 — Motor Controls and Indicators diagram (page 21)
Fig. 17 · Motor Controls and Indicators

F IG . 5. Motor Controls and Indicators

Motor ON/OFF Key/LED

PSI/BAR Keys/LEDs

Press to turn motor ON and OFF. Also

Press or to change pressure scale.

PSI BAR

clears some motor control diagnostic codes, see page 43.

Pressure Key/LED

PARK Key/LED

Press to display fluid pressure.

Press at end of day to cycle component

A pump to home position, submerging dis- placement rod. Trigger gun until pump stops. Once parked, motor will automatically shut off.

If pressures are imbalanced, display shows higher of two pressures.

Show 5 more labels / short text on this page
Pressure/Cycle Display · Arrow Keys · Motor ON/OFF Key · PARK Key · Pressure Key
Page 22 of the Graco H50 user manual — Motor Control Arrow Keys
Page 22 · click to enlarge
Page 22

Cycle Count Key/LED

Spray Adjustments

Press to display cycle count.

Flow rate, atomization, and amount of over- spray are affected by four variables.

  • Fluid pressure setting. Too little pressure results in an uneven pattern, coarse droplet size, low flow, and poor mixing. Too much pressure results in excessive overspray, high flow rates, difficult control, and excessive wear.

To clear counter, press and hold

for 3 sec.

Hydraulic Pressure Control Knob

  • Fluid temperature. Similar effects to fluid pressure setting. The A and B temperatures can be offset to help balance the fluid pressure.

Use to adjust hydraulic pressure available to the hydraulic drive system. Turn knob (HC) clockwise to increase pressure and counter- clockwise to decrease pressure. Use hydraulic pressure gauge (HP, page 17) to view hydrau- lic pressure.

  • Mix chamber size. Choice of mix chamber is based on desired flow rate and fluid viscosity.
  • Clean-off air adjustment. Too little clean-off air results in droplets building up on the front of the nozzle, and no pattern containment to control overspray. Too much clean-off air results in air-assisted atomization and excessive overspray.

+ -

Component A and B outlet pressures will be higher than the hydraulic set pressure, depending on the model (see Pressure Ratio data; Systems, page 3). Component A and B pressure may be viewed on the pressure gauges (GA, GB), or the higher of the two pressures may be displayed on the motor control panel (MC). See FIG. 3, page 17.

Motor Control Arrow Keys

Use or to:

  • Adjust pressure imbalance settings, page 33.
  • Adjust standby settings, page 37.

Spray Adjustments · ti7731a ti7732a

Page 23 of the Graco H50 user manual — 1. Locate Reactor
Page 23 · click to enlarge
Page 23

Setup

2. General equipment guidelines

  • Determine the correct size generator. Using the correct size generator and proper air compressor will enable the proportioner to run at a nearly constant RPM. Failure to do so will cause voltage fluctuations that can damage electrical equipment. Ensure the generator matches the voltage and phase of the proportioner.

1. Locate Reactor

Use the following procedure to determine the correct size generator.

a. Locate Reactor on a level surface. See

Dimensions, page 48, for clearance and mounting hole dimensions.

a. List system components that use peak

load requirements in watts.

b. Do not expose Reactor to rain.

b. Add the wattage required by the system

components.

c. Perform the following equation:

Total watts x 1.25 = kVA (kilo- volt-amperes)

d. Select a generator size that is equal to

c. Use the casters to move Reactor to a

or greater than the determined kVA.

fixed location, or bolt to shipping pallet and move with forklift.

  • Use proportioner power cords that meet or exceed the requirements listed in Table 2. Failure to do so will cause voltage fluctuations that can damage electrical equipment.

d. To mount on a truck bed or trailer,

remove casters and bolt directly to truck or trailer bed. See page 48.

  • Use an air compressor with constant speed head unloading devices. Direct online air compressors that start and stop during a job will cause voltage fluctuations that can damage electrical equipment.

Setup

Page 24 of the Graco H50 user manual — Table 1 : Electrical Requirements
Page 24 · click to enlarge
Page 24
  • Maintain and inspect the generator, air compressor, and other equipment per the manufacturer recommendations to avoid an unexpected shutdown. Unexpected equipment shutdown will cause voltage fluctuations that can damage electrical equipment.

Table 1 : Electrical Requirements

(kW/Full Load Amps)

Full Load Peak Amps*

253407 H-40 230V (3) 95 31,700 253408 H-40 400V (3) 52 31,700 255400 H-25 230V (1) 69 15,960 255401 H-25 230V (3) 46 15,960 255402 H-25 400V (3) 35 15,960 255403 HXP2 230V (1) 100 23,260 255404 HXP2 230V (3) 59 23,260 255405 HXP2 400V (3) 35 23,260 255406 H-25 230V (1) 100 23,260 255407 H-25 230V (3) 59 23,260 255408 H-25 400V (3) 35 23,260 253725 H-50 230V (1) 100 23,100 253726 H-50 230V (3) 71 26,600 253727 H-50 400V (3) 41 26,600 256505 H-50 230V (3) 95 31,700 256506 H-50 400V (3) 52 31,700

  • Use a wall power supply with enough current to meet system requirements. Failure to do so will cause voltage fluctuations that can damage electrical equipment.
3. Electrical requirements See Table 1.

Installing this equipment requires access to parts which may cause electric shock or other serious injury if work is not performed properly. Have a qualified electrician connect power and ground to main power switch ter- minals, see page 25. Be sure your installa- tion complies with all National, State and Local safety and fire codes.

* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.

** Total system watts, based on maximum hose length for each unit:

Table 1 : Electrical Requirements

(kW/Full Load Amps)

  • Parts 255400 through 255408, 310 ft (94.6 m) maximum heated hose length, including whip hose.

Full Load Peak Amps*

  • Parts 253400 through 253408, 410 ft (125 m) maximum heated hose length, including whip hose.

253400 H-40 230V (1) 100 23,100 253401 H-40 230V (3) 71 26,600 253402 H-40 400V (3) 41 26,600 253403 H-XP3 230V (1) 100 23,100 253404 H-XP3 230V (3) 95 31,700 253405 H-XP3 400V (3) 52 31,700

Show 7 more labels / short text on this page
Setup · Voltage (phase) · System Watts** · Part Model · Voltage (phase) · System Watts** · Part Model
Page 25 of the Graco H50 user manual — GND
Page 25 · click to enlarge
Page 25

4. Connect electrical cord

Power cord is not supplied. See Table 2.

Table 2Power Cord Requirements a. 230V, 1 phase: Using 5/32 or 4 mm hex

Cord Specification AWG (mm2)

allen wrench, connect two power leads to L1 and L2. Connect green to ground (GND).

253400 H-40 4 (21.2), 2 wire + ground 253401 H-40 4 (21.2), 3 wire + ground 253402 H-40 8 (8.4), 4 wire + ground 253403 H-XP3 4 (21.2), 2 wire + ground 253404 H-XP3 4 (21.2), 3 wire + ground 253405 H-XP3 6 (13.3), 4 wire + ground 253407 H-40 4 (21.2), 3 wire + ground 253408 H-40 6 (13.3), 4 wire + ground 255400 H-25 4 (21.2), 2 wire + ground 255401 H-25 8 (8.4), 3 wire + ground 255402 H-25 8 (8.4), 4 wire + ground 255403 H-XP2 4 (21.2), 2 wire + ground 255404 H-XP2 6 (13.3), 3 wire + ground 255405 H-XP2 8 (8.4), 4 wire + ground 255406 H-25 4 (21.2), 2 wire + ground 255407 H-25 6 (13.3), 3 wire + ground 255408 H-25 8 (8.4), 4 wire + ground 253725 H-50 4 (21.2), 2 wire + ground 253726 H-50 4 (21.2), 3 wire + ground 253727 H-50 8 (8.4), 4 wire + ground 256505 H-50 4 (21.2), 3 wire + ground 256506 H-50 6 (13.3), 4 wire + ground

Graco H50 — 4. Connect electrical cord diagram (page 25)
Fig. 18 · 4. Connect electrical cord

GND

b. 230V, 3 phaseUsing 5/32 or 4 mm hex

allen wrench, connect three power leads to L1, L2, and L3. Connect green to ground (GND).

Graco H50 — GND diagram (page 25)
Fig. 19

GND

Show 4 more labels / short text on this page
Setup · Part Model · ti2515b · ti3248b
Page 26 of the Graco H50 user manual — FP
Page 26 · click to enlarge
Page 26
c. 400V, 3 phaseUsing 5/32 or 4 mm hex

c. Install agitator (L) in component B drum,

allen wrench, connect three power leads to L1, L2, and L3. Connect neutral to N. Connect green to ground (GND).

if necessary.

d. Ensure A and B inlet valves (FV) are

Graco H50 — Setup diagram (page 26)
Fig. 20 · Setup

closed.

Graco H50 — Setup diagram (page 26)
Fig. 21 · Setup

GND

N

FV

Supply hoses from feed pumps should be 3/4 in. (19 mm) ID.

Some 3-phase models utilize a 3-phase motor. The motor must rotate counter- clockwise when viewed from shaft end. To reverse rotation, disconnect power and reverse power leads L1 and L2.

5. Connect feed pumps

a. Install feed pumps (K) in component A

and B supply drums. See FIG. 1 and FIG. 2, pages 14 and 15.

A minimum feed pressure of 50 psi (0.35 MPa, 3.5 bar) is required at both feed inlet pressure gauges (FP). Maxi- mum feed pressure is 250 psi (1.75 MPa, 17.5 bar). Maintain A and B feed pressures within 10% of each other.

Graco H50 — 5. Connect feed pumps diagram (page 26)
Fig. 22 · 5. Connect feed pumps

FP

b. Seal component A drum and use desic-

cant dryer (M) in vent.

Setup

Page 27 of the Graco H50 user manual — 7. Install Fluid Temperature Sensor (FTS)
Page 27 · click to enlarge
Page 27

6. Connect pressure relief lines

Graco H50 — 6. Connect pressure relief lines diagram (page 27)
Fig. 23 · 6. Connect pressure relief lines

SB SA

Do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as overpres-

R

BB R

sure relief valves when set to SPRAY . Lines must be open so valves can automati- cally relieve pressure when machine is oper- ating.

b. AlternatelySecure supplied bleed

If circulating fluid back to the supply drums, use high pressure hose rated to withstand the maximum working pressure of this equipment.

tubes (N) in grounded, sealed waste containers (H). See FIG. 2, page 15.

7. Install Fluid Temperature Sensor (FTS)

a. RecommendedConnect high pressure

The Fluid Temperature Sensor (FTS) is sup- plied. Install FTS between main hose and whip hose. See Heated Hose manual 309572 for instructions.

hose (R) to relief fittings (BA, BB) of both PRESSURE RELIEF/SPRAY valves, Route hose back to component A and B drums. See FIG. 1, page 14.

Setup · ti9880a BA

Page 28 of the Graco H50 user manual — 11.Pressure check hose
Page 28 · click to enlarge
Page 28

8. Connect heated hose

d. Connect cables (Y). Connect electrical

connectors (V). Be sure cables have slack when hose bends. Wrap cable and electrical connections with electri- cal tape.

See Heated Hose manual 309572 for detailed instructions on connecting heated hoses.

Graco H50 — 8. Connect heated hose diagram (page 28)
Fig. 24 · 8. Connect heated hose

The fluid temperature sensor (C) and whip hose (D) must be used with heated hose, see page 27. Hose length, including whip hose, must be 60 ft (18.3 m) minimum.

Y

a. Turn main power OFF .

b. Assemble heated hose sections, FTS,

9. Close gun fluid manifold valves A and B

and whip hose.

Graco H50 — 9. Close gun fluid manifold valves A and B diagram (page 28)
Fig. 25 · 9. Close gun fluid manifold valves A and B

c. Connect A and B hoses to A and B out-

lets on Reactor fluid manifold (FM). Hoses are color coded: red for compo- nent A (ISO), blue for component B (RES). Fittings are sized to prevent con- nection errors.

Graco H50 — 9. Close gun fluid manifold valves A and B diagram (page 28)
Fig. 26 · 9. Close gun fluid manifold valves A and B

10.Connect whip hose to gun fluid manifold

Do not connect manifold to gun.

Graco H50 — 10.Connect whip hose to gun fluid manifold diagram (page 28)
Fig. 27 · 10.Connect whip hose to gun fluid manifold

11.Pressure check hose

Manifold hose adapters (N, P) allow use of 1/4 in. and 3/8 in. ID fluid hoses. To use 1/2 in. (13 mm) ID fluid hoses, remove adapters from fluid manifold and install as needed to connect whip hose.

See hose manual. Pressure check for leaks. If no leaks, wrap hose and electrical connections to protect from damage.

Setup

Page 29 of the Graco H50 user manual — 13.Check hydraulic fluid level
Page 29 · click to enlarge
Page 29

12.Ground system

14.Lubrication system setup

Component A (ISO) Pump: Fill ISO lube reservoir (LR) with Graco Throat Seal Liq- uid (TSL), Part 206995 (supplied).

a. Lift the lubricant reservoir (LR) out of

a. Reactoris grounded through power

the bracket (RB) and remove the con- tainer from the cap.

cord. See page 25.

Graco H50 — 12.Ground system diagram (page 29)
Fig. 28 · 12.Ground system
b. Spray gunconnect whip hose ground

RT ST

wire to FTS, page 27. Do not discon- nect wire or spray without whip hose.

RB

c. Fluid supply containersfollow your

LR

local code.

d. Object being sprayedfollow your local

code.

e. Solvent pails used when flushing: follow

b. Fill with fresh lubricant. Thread the res-

your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place pail on a nonconductive surface, such as paper or cardboard, which interrupts ground- ing continuity

ervoir onto the cap assembly and place it in the bracket (RB).

c. Push the larger diameter supply tube

(ST) approximately 1/3 of the way into the reservoir.

f. To maintain grounding continuity when flushing or relieving pressure, hold a metal part of spray gun firmly to the side of a grounded metal pail, then trigger gun.

d. Push the smaller diameter return tube

(RT) into the reservoir until it reaches the bottom.

13.Check hydraulic fluid level

Hydraulic reservoir is filled at the factory. Check fluid level before operating the first time, and weekly thereafter. See Mainte- nance, page 44.

e. The lubrication system is ready for

operation. No priming is required.

Setup

Page 30 of the Graco H50 user manual — 7. Load fluid with feed pumps
Page 30 · click to enlarge
Page 30

Startup

a. Check that all Setup steps are com-

plete.

b. Check that inlet screens are clean

before daily startup, page 45.

c. Check level and condition of ISO lube

daily, page 44.

d. Turn on component B agitator, if used.

e. Turn both PRESSURE RELIEF/SPRAY

valves (SA, SB) to SPRAY .

Do not operate Reactor without all covers and shrouds in place.

Graco H50 — Startup diagram (page 30)
Fig. 29 · Startup

SA SB

1. Check generator fuel level. Running out of fuel will cause voltage fluctuations that can damage electrical equipment.
2. Ensure the main breaker on the generator is in the off position.

f. Start feed pumps.

3. Start the generator. Allow it to reach full operating temperature.

g. Open fluid inlet valves (FV). Check for

4. Close the bleed valve on the air compressor.

leaks.

Graco H50 — SA SB diagram (page 30)
Fig. 30
5. Switch on the air compressor starter and air dryer, if included.

FV

6. Turn on power to the Reactor.

7. Load fluid with feed pumps

The Reactor is tested with oil at the fac- tory. Flush out the oil with a compatible solvent before spraying. See page 47.

Startup

Page 31 of the Graco H50 user manual — B
Page 31 · click to enlarge
Page 31
Graco H50 — Startup diagram (page 31)
Fig. 31 · Startup
Graco H50 — Startup diagram (page 31)
Fig. 32 · Startup

This equipment is used with heated fluid, which can cause equipment surfaces to become very hot. To avoid severe burns:

Do not mix components A and B during startup. Always provide two grounded waste containers to keep component A and compo- nent B fluids separate.

  • Do not touch hot fluid or equipment.
  • Allow equipment to cool completely before touching it.
  • Wear gloves if fluid temperature exceeds 110°F (43°C).

h. Use feed pumps to load system. Hold

gun fluid manifold over two grounded waste containers. Open fluid valves A and B until clean, air-free fluid comes from valves. Close valves.

Graco H50 — Startup diagram (page 31)
Fig. 33 · Startup

b. Press or to change tem-

° F ° C

perature scale.

c. Press to display target tempera-

tures.

8. Set temperatures

Graco H50 — 8. Set temperatures diagram (page 31)
Fig. 34 · 8. Set temperatures

d. To set heat zone target tempera-

A

ture, press or until display

shows desired temperature. Repeat for

B

and zones.

For zone only, if FTS is discon-

nected at startup, display will show hose current (0A). See step j, page 32.

Temperature Controls and Indicators, see page 18

Startup

Page 32 of the Graco H50 user manual — A B
Page 32 · click to enlarge
Page 32

j. Manual current control mode only:

e. Press to display actual tempera-

Graco H50 — Startup diagram (page 32)
Fig. 35 · Startup

tures.

Graco H50 — Startup diagram (page 32)
Fig. 36 · Startup

When in manual current control mode, moni- tor hose temperature with thermometer. Install per instructions below. Thermometer reading must not exceed 160°F (71°C). Never leave machine unattended when in manual current control mode.

Do not turn on hose heat without fluid in hoses.

f. Turn on heat zone by pressing

If FTS is disconnected or display shows diagnostic code E04, turn main power

. Preheat hose (15-60 min). Indi-

cator will flash very slowly when fluid reaches target temperature. Display shows actual fluid temperature in hose near FTS.

switch OFF then ON to

clear diagnostic code and enter manual

current control mode. display will

show current to hose. Current is not lim- ited by target temperature.

Graco H50 — Startup diagram (page 32)
Fig. 37 · Startup

Thermal expansion can cause overpressur- ization, resulting in equipment rupture and serious injury, including fluid injection. Do not pressurize system when preheating hose.

Press or to adjust current

setting.

To prevent overheating, install hose thermometer close to gun end, within operator view. Insert thermometer through foam cover of A component hose so stem is next to inner tube. Thermometer reading will be about 20°F less than actual fluid temperature.

A B

g. Turn on and heat zones by

pressing for each zone.

If thermometer reading exceeds 160°F

(71°C), reduce current with key.

h. Hold to view electrical currents for

each zone.

i. Hold to view heater control circuit

board temperature.

Startup

Page 33 of the Graco H50 user manual — + -
Page 33 · click to enlarge
Page 33

9. Set pressure

Check the pressure of each proportion- ing pump using the component A and B gauges. The pressures should be approximately equal and must remain fixed.

Graco H50 — 9. Set pressure diagram (page 33)
Fig. 38 · 9. Set pressure

d. To display cycle count, press .

To clear counter, press and hold

for 3 sec.

e. Press or to change pres-

PSI BAR

Motor Controls and Indicators, see page 21

sure scale.

10.Change pressure imbalance setting (optional)

a. Press to display the pressure

reading.

The pressure imbalance function (status code 24, page 43) detects conditions that can cause off-ratio spray, such as loss of feed pres- sure/supply, pump seal failure, clogged fluid inlet filter, or a fluid leak.

b. Press motor . Motor and pumps

start. Display shows system pressure.

Motor must rotate counterclockwise when viewed from shaft end. See Con- nect electrical cord, page 25.

Code 24 (pressure imbalance) is set to an alarm as the default. To change to a warning, see Reactor Repair-Parts manual 312063.

c. Adjust hydraulic pressure control until

The pressure imbalance default is factory-set at 500 psi (3.5 MPa, 35 bar). For tighter ratio error detection, select a lower value. For looser detection or to avoid nuisance alarms, select a higher value.

display shows desired fluid pressure.

+ -

a. Turn main power switch OFF .

If display pressure is greater than desired pressure, reduce the hydraulic pressure and trigger gun to reduce pressure.

Startup · ti7731a ti7732a

Page 34 of the Graco H50 user manual — PSI BAR PSI BAR
Page 34 · click to enlarge
Page 34

b. Press and hold or , then turn

PSI BAR

main power switch ON . Display

will read dP500 for psi or dP_35 for bar.

c. Press or to select desired

pressure differential (100-999 in incre- ments of 100 psi, or 7-70 in increments of 7 bar). See TABLE 3.

Table 3Available Pressure Imbalance Settings

PSI BAR PSI BAR

100 7 600 42 200 14 700 49 300 21 800 56 400 28 900 63 *500 *35 999 69

* Factory default setting.

d. Turn main power switch OFF to

save changes.

Startup

Page 35 of the Graco H50 user manual — GA GB
Page 35 · click to enlarge
Page 35

Spraying

4. Set PRESSURE RELIEF/SPRAY valves

(SA, SB) to SPRAY .

SA

SB

1. Engage gun piston safety lock.
Graco H50 — SA diagram (page 35)
Fig. 39
5. Check that heat zones are on and temperatures are on target, page 31.
2. Close gun fluid manifold valves A and B.
6. Press motor to start motor and
Graco H50 — SA diagram (page 35)
Fig. 40

pumps.

7. Check fluid pressure display and adjust as necessary.
8. Check fluid pressure gauges (GA, GB) to ensure proper pressure balance. If imbalanced, reduce pressure of higher component by slightly turning PRESSURE RELIEF/SPRAY valve for that component toward PRESSURE RELIEF/CIRCULA-
3. Attach gun fluid manifold. Connect gun air line. Open air line valve.
Graco H50 — SA diagram (page 35)
Fig. 41

TION , until gauges show balanced pressures.

GA GB

In this example, B side pressure is higher, so use the B side valve to balance pressures.

Graco H50 — GA GB diagram (page 35)
Fig. 42

Spraying

Page 36 of the Graco H50 user manual — Spraying
Page 36 · click to enlarge
Page 36
9. Open gun fluid manifold valves A and B. 10.Disengage gun piston safety lock.
Graco H50 — Spraying diagram (page 36)
Fig. 43 · Spraying
Graco H50 — Spraying diagram (page 36)
Fig. 44 · Spraying

11.Test spray onto cardboard. Adjust pressure and temperature to get desired results.

12.Equipment is ready to spray.

On impingement guns, never open fluid manifold valves or trigger gun if pres- sures are imbalanced.

If you stop spraying for a period of time, the unit will enter standby (if enabled). See page 37.

Spraying

Page 37 of the Graco H50 user manual — A B
Page 37 · click to enlarge
Page 37

Standby

To activate or disable standby, adjust DIP switch #3 on the motor control board. See Reactor Repair-Parts manual 312063.

If you stop spraying for a period of time, the unit will enter standby by shutting down the electric motor and hydraulic pump, to reduce equipment wear and minimize heat buildup. The ON/OFF LED and the pressure/cycle dis- play on the motor control panel will flash when in standby.

The idle time before entering standby is user-settable as follows:

1. Turn main power switch OFF .
2. Press and hold , then turn main power

A B

The , , and heat zones

switch ON .

will not be shut off in standby.

To restart, spray off target for 2 sec. The sys- tem will sense the pressure drop and the motor will ramp up to full speed in a few seconds.

3. Press or to select desired timer

setting (5-20, in 5 minute increments). This sets the length of inactive time before the unit will enter standby.

This feature is disabled from the factory.

4. Turn main power switch OFF to

save changes.

Standby

Page 38 of the Graco H50 user manual — A B
Page 38 · click to enlarge
Page 38

Shutdown

9. Close both fluid supply valves (FV).
Graco H50 — Shutdown diagram (page 38)
Fig. 45 · Shutdown

10.Shut down feed pumps as required.

1. Shut off , , and heat

A B

zones.

2. Park pumps.

a. Press .

b. Trigger gun until pump A stops in the

retracted position and the pressure of both pumps bleeds down.

3. Turn main power OFF .
4. Relieve pressure, page 39.
5. Turn off the air compressor and air dryer, if included.
6. Open air compressor bleed valve to relieve pressure and remove water from tank.
7. Turn off the main breaker on the generator.
8. Allow generator dwell time, per manufacturer recommendations, prior to shutdown.

Shutdown · ti9883a FV

Page 39 of the Graco H50 user manual — SA
Page 39 · click to enlarge
Page 39

Pressure Relief Procedure

5. Turn PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE RELIEF/CIRCU-

LATION . Route fluid to waste contain- ers or supply tanks. Ensure gauges drop to 0.

1. Relieve pressure in gun and perform gun shutdown procedure. See gun manual.
Graco H50 — Pressure Relief Procedure diagram (page 39)
Fig. 46 · Pressure Relief Procedure
2. Engage gun piston safety lock.

SA

SB

3. Close gun fluid manifold valves A and B.
6. Disconnect gun air line and remove gun fluid manifold.
Graco H50 — SA diagram (page 39)
Fig. 47
Graco H50 — SA diagram (page 39)
Fig. 48
4. Shut off feed pumps and agitator, if used.

Pressure Relief Procedure

Page 40 of the Graco H50 user manual — A B
Page 40 · click to enlarge
Page 40

Fluid Circulation

Circulation Through Reactor

3. Set PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE RELIEF/CIRCU-

LATION .

Graco H50 — Fluid Circulation diagram (page 40)
Fig. 49 · Fluid Circulation

Do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits.

SA

SB

To circulate through gun manifold and preheat hose, see page 41.

1. Follow Startup procedures, page 30.
4. Turn main power ON .
5. Set temperature targets, see page 31. Turn

A B

on and heat zones by pressing

Do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as overpres-

. Do not turn on heat zone

unless hoses are already loaded with fluid.

sure relief valves when set to SPRAY . Lines must be open so valves can automati- cally relieve pressure when machine is oper- ating.

6. Press to display actual temperatures.
7. Before starting motor, reduce hydraulic pressure to the minimum required to circu-
2. See Typical Installation, with circulation , page 14. Route circulation lines back to respective component A or B supply drum. Use hoses rated at the maximum working pressure of this equipment. See Technical Data , page 49.

late fluid until and tempera-

A B

tures reach targets.

8. Press motor to start motor and

pumps. Circulate fluid at lowest possible pressure until temperatures reach targets.

9. Turn on heat zone by pressing .

Fluid Circulation

Page 41 of the Graco H50 user manual — P
Page 41 · click to enlarge
Page 41

10.Set PRESSURE RELIEF/SPRAY valves

3. Follow Startup procedures, page 30.

(SA, SB) to SPRAY .

Graco H50 — Circulation Through Gun Manifold diagram (page 41)
Fig. 50 · Circulation Through Gun Manifold
4. Turn main power ON .

SA

5. Set temperature targets, see page 31. Turn

SB

A B

on , , and heat zones by

pressing .

Circulation Through Gun Manifold

6. Press to display actual temperatures.
7. Before starting motor, reduce hydraulic pressure to the minimum required to circu-

A B

late fluid until and tempera-

tures reach targets.

Do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits.

Circulating fluid through the gun manifold allows rapid preheating of hose.

1. Install gun fluid manifold (P) on Part 246362 accessory circulation kit (CK). Connect high pressure circulation lines (R) to circulation manifold.
8. Press motor to start motor and

pumps. Circulate fluid at lowest possible pressure until temperatures reach targets.

Graco H50 — A B diagram (page 41)
Fig. 51

P

R CK

2. Route circulation lines back to respective component A or B supply drum. Use hoses rated at the maximum working pressure of this equipment. See Typical Installation, without circulation , page 15.

Fluid Circulation

Page 42 of the Graco H50 user manual — Temperature Control Diagnostic Codes
Page 42 · click to enlarge
Page 42

Diagnostic Codes

Temperature Control Diagnostic Codes

Temperature control diagnostic codes appear on temperature display.

Code Code Name Alarm Zone

01 High fluid temperature Individual

These alarms turn off heat. E99 clears auto- matically when communication is regained. Codes E03 through E06 can be cleared by

02 High current Individual

03 No current Individual

04 FTS not connected Individual

05 Board over-temperature Individual

pressing . For other codes, turn main

06 Loss of zone communication Individual

30 Momentary loss of communica- tion

power OFF then ON to clear.

99 Loss of display communication All

See repair manual for corrective action.

For hose zone only, if FTS is discon- nected at startup, display will show hose current 0A.

Diagnostic Codes · All

Page 43 of the Graco H50 user manual — Alarms
Page 43 · click to enlarge
Page 43

Motor Control Diagnostic Codes

Motor control diagnostic codes E21 through E27 appear on pressure display.

Warnings

Reactor will continue to run. Press to

There are two types of motor control codes: alarms and warnings. Alarms take priority over warnings.

clear. A warning will not recur for a predeter- mined amount of time (varies for different warnings), or until main power is turned OFF

See repair manual for corrective action.

then ON .

Alarms

Alarms turn off the motor and heat zones. Turn

Code Name Alarm or

No.

main power OFF then ON to

21 No transducer (component A) Alarm

clear.

22 No transducer (component B) Alarm

23 High pressure Alarm

24 Pressure imbalance Selectable; see repair manual

Alarms can also be cleared, except for

code 23, by pressing .

27 High motor temperature Alarm

30 Momentary loss of communi- cation

Code 24 (pressure imbalance) is set to an alarm default of 500 psi (3.5 MPa, 35 bar). To change to a warning, see Reac- tor Repair-Parts manual 312063. To change the default pressure imbalance setting, see page 33.

31 Pumpline switch failure/high cycle rate

99 Loss of communication Alarm

Show 4 more labels / short text on this page
Diagnostic Codes · Code · Alarm · Alarm
Page 44 of the Graco H50 user manual — DS
Page 44 · click to enlarge
Page 44

Maintenance

  • Change break-in oil in a new unit after first 250 hours of operation or within 3 months, whichever comes first. See Table 4 for recommended frequency of oil changes
  • Inspect hydraulic and fluid lines for leaks daily.

Table 4: Frequency of Oil Changes

  • Clean up all hydraulic leaks; identify and repair cause of leak.

Ambient Temperature

Recommended Frequency

  • Inspect fluid inlet strainer screens daily, see below.

0 to 90°F (-17 to 32°C)

1000 hours or 12 months, whichever comes first

  • Grease circulation valves weekly with Fusion grease (117773).

90°F and above (32°C and above)

500 hours or 6 months, whichever comes first

  • Keep component A from exposure to moisture in atmosphere, to prevent crystallization.
  • Clean gun mix chamber ports regularly. See gun manual.
  • Inspect ISO lubricant level and condition daily, see page 46. Refill or replace as needed.
  • Clean gun check valve screens regularly. See gun manual.
  • Check hydraulic fluid level weekly. Check hydraulic fluid level on dipstick (DS). Fluid level must be between indent marks (IM) on dipstick. Refill as required with approved hydraulic fluid; see Technical Data on page 49 and the Approved Anti-Wear (AW) Hydraulic Oils table in the Reactor Repair-Parts manual 312063. If fluid is dark in color, change fluid and filter.
  • Use compressed air to prevent dust buildup on control boards, fan, motor (under shield), and hydraulic oil coolers.
  • Keep vent holes on bottom of electrical cabinet open.
Graco H50 — Ambient Temperature diagram (page 44)
Fig. 52 · Ambient Temperature
Graco H50 — Ambient Temperature diagram (page 44)
Fig. 53 · Ambient Temperature

DS

S

IM

Maintenance

Page 45 of the Graco H50 user manual — F IG . 6. Fluid Inlet Strainer
Page 45 · click to enlarge
Page 45

Fluid Inlet Strainer Screen

5. Open the fluid inlet valve, ensure that there are no leaks, and wipe the equipment clean. Proceed with operation.
Graco H50 — Fluid Inlet Strainer Screen diagram (page 45)
Fig. 54 · Fluid Inlet Strainer Screen

The inlet strainers filter out particles that can plug the pump inlet check valves. Inspect the screens daily as part of the startup routine, and clean as required.

Use clean chemicals and follow proper stor- age, transfer, and operating procedures, to minimize contamination of the A-side screen.

F IG . 6. Fluid Inlet Strainer

* See Reactor Repair-Parts manual 312063 for fluid filter screen replacements.

Clean the A-side screen only during daily startup. This minimizes moisture contamination by immediately flushing out any isocyanate residue at the start of dispensing operations.

1. Close the fluid inlet valve at the pump inlet and shut off the appropriate feed pump. This prevents material from being pumped while cleaning the screen.
2. Place a container under the strainer manifold (59d) to catch fluid. Remove the strainer plug (59j).
3. Remove the screen (59g) from the strainer manifold. Thoroughly flush the screen with compatible solvent and shake it dry. Inspect the screen. If more than 25% of the mesh is blocked, replace the screen. Inspect the gasket (59h) and replace as required.
4. Ensure the pipe plug (59k) is screwed into the strainer plug (59j). Install the strainer plug with the screen (59g) and gasket (59h) in place and tighten. Do not overtighten. Let the gasket make the seal.
Show 6 more labels / short text on this page
Maintenance · 59d · 59g* · 59h · 59j · 59k
Page 46 of the Graco H50 user manual — F IG . 7. Pump Lubrication System
Page 46 · click to enlarge
Page 46

Pump Lubrication System

Check the condition of the ISO pump lubricant daily. Change the lubricant if it becomes a gel, its color darkens, or it becomes diluted with isocyanate.

Gel formation is due to moisture absorption by the pump lubricant. The interval between changes depends on the environment in which the equipment is operating. The pump lubrica- tion system minimizes exposure to moisture, but some contamination is still possible.

8. The lubrication system is ready for operation. No priming is required.
Graco H50 — Pump Lubrication System diagram (page 46)
Fig. 55 · Pump Lubrication System

ST

RT

Lubricant discoloration is due to continual seepage of small amounts of isocyanate past the pump packings during operation. If the packings are operating properly, lubricant replacement due to discoloration should not be necessary more often than every 3 or 4 weeks.

RB

LR

To change pump lubricant:

1. Relieve pressure, page 39.
Graco H50 — RB diagram (page 46)
Fig. 56
2. Lift the lubricant reservoir (LR) out of the bracket (RB) and remove the container from the cap. Holding the cap over a suitable container, remove the check valve and allow the lubricant to drain. Reattach the check valve to the inlet hose. See F IG . 7.

ST

RT

3. Drain the reservoir and flush it with clean lubricant.

LR

4. When the reservoir is flushed clean, fill with fresh lubricant.

F IG . 7. Pump Lubrication System

5. Thread the reservoir onto the cap assembly and place it in the bracket.
6. Push the larger diameter supply tube (ST) approximately 1/3 of the way into the reservoir.
7. Push the smaller diameter return tube (RT) into the reservoir until it reaches the bottom.

Maintenance

Page 47 of the Graco H50 user manual — N
Page 47 · click to enlarge
Page 47

Flushing

  • To flush feed hoses, pumps, and heaters separately from heated hoses, set PRESSURE RELIEF/SPRAY valves (SA, SB) to

PRESSURE RELIEF/CIRCULATION . Flush through bleed lines (N).

Flush equipment only in a well-ventilated area. Do not spray flammable fluids. Do not turn on heaters while flushing with flammable solvents.

SA

Graco H50 — SA diagram (page 47)
Fig. 57

SB

N

  • Flush out old fluid with new fluid, or flush out old fluid with a compatible solvent before introducing new fluid.

N

  • Use the lowest possible pressure when flushing.
  • To flush entire system, circulate through gun fluid manifold (with manifold removed from gun).
  • All fluid components are compatible with common solvents. Use only moisture-free solvents.
  • To prevent moisture from reacting with isocyanate, always leave the system dry or filled with a moisture-free plasticizer or oil. Do not use water. See page 12.

Flushing

Page 48 of the Graco H50 user manual — Top View
Page 48 · click to enlarge
Page 48

Dimensions

Dimension in. (mm)

Dimension in. (mm) A (height) 55.0 (1397) B (width) 39.6 (1006) C (depth) 18.5 (470) D (front mounting holes) 29.34 (745) E (rear mounting holes) 33.6 (853)

F (side mounting holes) 16.25 (413) G (mounting post inner diameter)0.44 (11) H (front mounting post height) 2.0 (51) J (rear mounting post height) 3.6 (92)

Graco H50 — Dimension in. (mm) diagram (page 48)
Fig. 58 · Dimension in. (mm)

Top View

Side View

Graco H50 — Top View diagram (page 48)
Fig. 59 · Top View

Detail of mounting post height, to

correctly size mounting bolts

Graco H50 — Top View diagram (page 48)
Fig. 60 · Top View

Dimensions · ti7742a ti7743a

Page 49 of the Graco H50 user manual — Technical Data
Page 49 · click to enlarge
Page 49

Technical Data

Category Data Maximum Fluid Working Pressure Models H-25 and H-40: 2000 psi (13.8 MPa, 138 bar) Model H-50 1 phase: 1700 psi (11.7 MPa, 11.7 bar) Model H-50 3 phase: 2000 psi (13.8 MPa, 138 bar) Models H-XP2 and H-XP3: 3500 psi (24.1 MPa, 241 bar) Fluid:Oil Pressure Ratio Models H-25 and H-40: 1.91:1 Model H-50: 1.64:1 Models H-XP2 and H-XP3: 2.79:1 Fluid Inlets Component A (ISO): 1/2 npt(f), 250 psi (1.75 MPa, 17.5 bar) maximum Component B (RES): 3/4 npt(f), 250 psi (1.75 MPa, 17.5 bar) maximum Fluid Outlets Component A (ISO): #8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter Component B (RES): #10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter Fluid Circulation Ports 1/4 npsm(m), with plastic tubing, 250 psi (1.75 MPa, 17.5 bar) maximum Maximum Fluid Temperature 190°F (88°C) Maximum Output (10 weight oil at ambient temperature)

Model H-25: 22 lb/min (10 kg/min) (60 Hz) Model H-XP2: 1.5 gpm (5.7 liter/min) (60 Hz) Model H-50: 52 lb/min (24 kg/min) (60 Hz) Model H-40: 45 lb/min (20 kg/min) (60 Hz) Model H-XP3: 2.8 gpm (10.6 liter/min) (60 Hz) Output per Cycle (A and B) Models H-25 and H-40: 0.063 gal. (0.23 liter) Model H-50: 0.073 gal. (0.28 liter) Models H-XP2 and H-XP3: 0.042 gal. (0.16 liter) Line Voltage Requirement 230V 1 phase and 230V 3 phase units: 195-264 Vac, 50/60 Hz 400V 3 phase units: 338-457 Vac, 50/60 Hz Amperage Requirement See Systems, page 3. Heater Power (A and B heaters total, no hose)

See Systems, page 3.

Hydraulic reservoir capacity 3.5 gal. (13.6 liters) Recommended hydraulic fluid Citgo A/W Hydraulic Oil, ISO Grade 46 Sound power, per ISO 9614-2 90.2 dB(A) Sound pressure, 1 m from equipment 82.6 dB(A)

Weight Units with 8.0 kW Heaters: 535 lb (243 kg)

Units with 12.0 kW Heaters597 lb (271 kg)

Units with 15.3 kW Heaters (H-25/H-XP2 models):562 lb (255 kg)

Units with 15.3 kW Heaters (H-40/H-XP3/H-50 models): 597 lb (271 kg)

Units with 20.4 kW Heaters: 597 lb (271 kg) Wetted Parts Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome, fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically resistant o-rings

All other brand names or marks are used for identification purposes and are trademarks of their respective owners.

Technical Data

Page 50 of the Graco H50 user manual — K
Page 50 · click to enlarge
Page 50

Performance Charts

Foam Performance Chart

2000 (13.8, 138)

KEY A = H-25 at 50 Hz B = H-25 at 60 Hz C = H-40 at 50 Hz D = H-40 at 60 Hz E = H-50 at 50 Hz ❄F = H-50 at 60 Hz

Pressure in psi (MPa, bar) Pressure in psi (MPa, bar)

1500 (10.3, 103)

A

B

1000 (6.9, 69)

E

D

500 (3.4, 34)

F

45 (20.5)

55 (25.0)

5 (2.3)

25 (11.4) 15 (6.8)

35 (15.9)

Flow Rate in lb/min (kg/min)

❄ Pressure flow curve for model 253725 (H-50 230V 1 phase) not shown. Maximum pressure limited to 1700 psi (11.7 MPa, 11.7 bar)

Coatings Performance Chart

3500 (24.1, 241)

KEY G = H-XP2 at 50 Hz H= H-XP2 at 60 Hz J = H-XP3 at 50 Hz K = H-XP3 at 60 Hz

3000 (20.7, 207)

2500 (17.2, 172)

G

2000 (13.8, 138)

H

1500 (10.3, 103)

J

1000 (6.9, 69)

K

500 (3.4, 34)

0 0.5 1.0 1.5 2.0 2.5 3.0 (1.9) (3.8) (5.7) (7.6) (9.5) (11.4)

Flow Rate in gal/min (liter/min)

Performance Charts

Page 51 of the Graco H50 user manual — M
Page 51 · click to enlarge
Page 51

Heater Performance Chart

140 (78) 130 (72) 120 (67) 110 (61) 100 (56)

KEY J = 8 kW K = 12 kW L = 15.3 kW M = 20.4 kW

Delta T in degrees F (degrees C)

M

K

J

0 0.5 (1.9)

2.0 (7.6) 1.0 (3.8)

2.5 (9.5) 1.5 (5.7)

4.0 (15.1) 3.0 (11.4)

3.5 (13.2)

4.5 (17.0)

Flow Rate in gpm (lpm)

★Heater performance data is based on testing with 10 wt.

hydraulic oil and 230V across heater power wires.

Show 10 more labels / short text on this page
Performance Charts · 90 (50) · 80 (44) · 70 (39) · 60 (33) · 50 (28) · 40 (22) · 30 (17) · 20 (11) · 10 (6)
Page 52 of the Graco H50 user manual — Graco Information
Page 52 · click to enlarge
Page 52

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents

Original Instructions. This manual contains English. MM 312062

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea
  • GRACO INC. AND SUBSIDIARIES
  • P.O. BOX 1441
  • MINNEAPOLIS MN 55440-1441
  • USA Copyright 2007, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com Revision W, September 2014

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Graco H50

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco H50

Be the first to ask — other owners or our team will answer.

Original document

Graco H50 manual PDF

52 pages·3.7 MB·Paint Sprayer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…