Hydraulic, Heated, Plural Component Proportioner For spraying polyurethane foam and polyurea coatings. For professional use only. Not approved for use in European explosive atmosphere locations.

See page 3 for model information, including maximum working pressure and approvals.
Model H-40 Shown · T9830a


★CE approval does not apply.
Systems

★CE approval does not apply.
Systems

Models



* Full load amps with all devices operating at maximum capabilities. Fuse requirements at vari- ous flow rates and mix chamber sizes may be less.
† Total system watts, based on maximum hose length for each unit:
◆ Maximum flow rate given for 60 Hz operation. For 50 Hz operation, maximum flow rate is 5/6 of
60 Hz maximum flow.
★CE approval does not apply.

Models

The following manuals are shipped with the Reactor™ Proportioner. Refer to these manu- als for detailed equipment information.
Order Part 15M334 for a compact disk of Reactor manuals translated in several lan- guages.
Manuals are also available at www.graco.com
Supplied Manuals

The following manuals are for accessories used with the Reactor™.
Order Part 15M334 for a compact disk of Reactor manuals translated in several lan- guages.
Related Manuals

The following warnings are for the setup, use, grounding, maintenance, and repair of this equip- ment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.



Isocyanate Conditions
Keep Components A and B Separate
Spraying or dispensing materials containing isocyanates creates potentially harmful mists, vapors, and atomized particulates.
Cross-contamination can result in cured material in fluid lines which could cause seri- ous injury or damage equipment. To prevent cross-contamination of the equipment’s wet- ted parts, never interchange component A (isocyanate) and component B (resin) parts.
Read material manufacturer’s warnings and material MSDS to know specific hazards and precautions related to isocyanates.
Prevent inhalation of isocyanate mists, vapors, and atomized particulates by pro- viding sufficient ventilation in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for every- one in the work area.
Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce perfor- mance and the life of all wetted parts.
To prevent contact with isocyanates, appro- priate personal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area.
The amount of film formation and rate of crystallization varies depending on the blend of ISO, the humidity, and the tem- perature.
To prevent exposing ISO to moisture:
Some materials may become self-igniting if applied too thickly. Read material manufac- turer’s warnings and material MSDS.

Some foam blowing agents will froth at tem- peratures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system.

Typical Installation, with circulation
A Reactor Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Fusion Spray Gun F Gun Air Supply Hose
G Feed Pump Air Supply Lines J Fluid Supply Lines K Feed Pumps L Agitator M Desiccant Dryer P Gun Fluid Manifold (part of gun) R Circulation Lines

* Shown exposed for clarity. Wrap with tape during operation.

Typical Installation, without circulation
A Reactor Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Fusion Spray Gun F Gun Air Supply Hose G Feed Pump Air Supply Lines
H Waste Containers J Fluid Supply Lines K Feed Pumps L Agitator M Desiccant Dryer N Bleed Lines P Gun Fluid Manifold (part of gun)
A Side Supply Detail


K

L G
J
A
J
F
N H
D
E
P
C*
* Shown exposed for clarity. Wrap with tape during operation.
F IG . 2: Typical Installation, without circulation

BA Component A Pressure Relief Outlet BB Component B Pressure Relief Outlet EC Heated Hose Electrical Connector EM Electric Motor, Fan, and Belt Drive (behind shroud) FA Component A Fluid Manifold Inlet (on left side of manifold
block) FB Component B Fluid Manifold Inlet FH Fluid Heater (behind shroud) FM Reactor Fluid Manifold FP Feed Inlet Pressure Gauge FS Feed Inlet Strainer FT Feed Inlet Temperature Gauge FV Fluid Inlet Valve (B side shown) GA Component A Outlet Pressure Gauge GB Component B Outlet Pressure Gauge HA Component A Hose Connection HB Component B Hose Connection HC Hydraulic Pressure Control HP Hydraulic Pressure Gauge LR ISO Lube Pump Reservoir MC Motor Control Display MP Main Power Switch OP Overpressure Rupture Disk Assembly (on rear of A and B
pumps) PA Component A Pump PB Component B Pump RS Red Stop Button SA Component A PRESSURE RELIEF/SPRAY Valve SB Component B PRESSURE RELIEF/SPRAY Valve SC Fluid Temperature Sensor Cable SN Serial Number Plate (one inside cabinet, one on right side
of cabinet) SR Electrical Cord Strain Relief TA Component A Pressure Transducer (behind gauge GA) TB Component B Pressure Transducer (behind gauge GB) TC Temperature Control Display TD Oil Cooler
Component Identification


PA
OP
FT
FP
PB
FV
Detail of Reactor Fluid Manifold
(shroud removed for clarity)
SA
TA
GA GB

FA

FB
HB
SN
F IG . 3: Component Identification (H40 15.3 kW Model Shown)
Component Identification

Temperature Controls and Indicators


Zone A Arrow Keys
Heater A On/Off Key
Zone B Arrow Keys
Heater B On/Off Key
Hose Zone Arrow Keys
Hose Heater On/Off Key
Main Power Switch
Red Stop Button
Located on right side of unit, page 17. Turns
Located between temperature control panel and motor control panel, page 17. Press
Reactor power ON and OFF .
to shut off motor and heater zones
Does not turn heater zones or pumps on.
only. Use main power switch to shut off all power to unit.

Temperature Controls and Indicators
Heater Zone On/Off Keys/LEDs
Press to display actual temperature.
Press to turn heater zones on and off.
Also clears heater zone diagnostic codes, see page 42.
Press and hold to display electrical cur-
rent.
LEDs flash when heater zones are on. The duration of each flash shows the extent that the heater is turned on.
Press to display target temperature.
Press and hold to display heater control
Press , then press or to
circuit board temperature.
adjust temperature settings in 1 degree incre- ments.
Temperature Displays
Show actual temperature or target tempera- ture of heater zones, depending on selected mode. Defaults to actual at startup. Range is 32-190°F (0-88°C) for A and B, 32-180°F (0-82°C) for hose.
Press or to change temperature
scale.

Temperature Controls and Indicators
* Depending on model.

Located inside Reactor cabinet.
Ref. Size Component
CB1 50 A Hose/Transformer Secondary
CB2 40 A Transformer Primary
CB3 25, 40, or 50 A* Heater A
For wiring and cabling, see repair manual 312063.
CB4 25, 40, or 50 A* Heater B
CB5 20 or 30 A* Motor/Pumps
ti9884a CB3 CB4

Motor Controls and Indicators


Motor ON/OFF Key/LED
PSI/BAR Keys/LEDs
Press to turn motor ON and OFF. Also
Press or to change pressure scale.
clears some motor control diagnostic codes, see page 43.
PARK Key/LED
Press to display fluid pressure.
Press at end of day to cycle component
A pump to home position, submerging dis- placement rod. Trigger gun until pump stops. Once parked, motor will automatically shut off.
If pressures are imbalanced, display shows higher of two pressures.

Spray Adjustments
Press to display cycle count.
Flow rate, atomization, and amount of over- spray are affected by four variables.
To clear counter, press and hold
for 3 sec.
Use to adjust hydraulic pressure available to the hydraulic drive system. Turn knob (HC) clockwise to increase pressure and counter- clockwise to decrease pressure. Use hydraulic pressure gauge (HP, page 17) to view hydrau- lic pressure.
Component A and B outlet pressures will be higher than the hydraulic set pressure, depending on the model (see Pressure Ratio data; Systems, page 3). Component A and B pressure may be viewed on the pressure gauges (GA, GB), or the higher of the two pressures may be displayed on the motor control panel (MC). See FIG. 3, page 17.
Use or to:
Spray Adjustments · ti7731a ti7732a

Use the following procedure to determine the correct size generator.
a. Locate Reactor on a level surface. See
Dimensions, page 48, for clearance and mounting hole dimensions.
a. List system components that use peak
load requirements in watts.
b. Do not expose Reactor to rain.
b. Add the wattage required by the system
components.
c. Perform the following equation:
Total watts x 1.25 = kVA (kilo- volt-amperes)
d. Select a generator size that is equal to
c. Use the casters to move Reactor to a
or greater than the determined kVA.
fixed location, or bolt to shipping pallet and move with forklift.
d. To mount on a truck bed or trailer,
remove casters and bolt directly to truck or trailer bed. See page 48.
Setup

(kW/Full Load Amps)
Full Load Peak Amps*
253407 H-40 230V (3) 95 31,700 253408 H-40 400V (3) 52 31,700 255400 H-25 230V (1) 69 15,960 255401 H-25 230V (3) 46 15,960 255402 H-25 400V (3) 35 15,960 255403 HXP2 230V (1) 100 23,260 255404 HXP2 230V (3) 59 23,260 255405 HXP2 400V (3) 35 23,260 255406 H-25 230V (1) 100 23,260 255407 H-25 230V (3) 59 23,260 255408 H-25 400V (3) 35 23,260 253725 H-50 230V (1) 100 23,100 253726 H-50 230V (3) 71 26,600 253727 H-50 400V (3) 41 26,600 256505 H-50 230V (3) 95 31,700 256506 H-50 400V (3) 52 31,700
Installing this equipment requires access to parts which may cause electric shock or other serious injury if work is not performed properly. Have a qualified electrician connect power and ground to main power switch ter- minals, see page 25. Be sure your installa- tion complies with all National, State and Local safety and fire codes.
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.
** Total system watts, based on maximum hose length for each unit:
(kW/Full Load Amps)
Full Load Peak Amps*
253400 H-40 230V (1) 100 23,100 253401 H-40 230V (3) 71 26,600 253402 H-40 400V (3) 41 26,600 253403 H-XP3 230V (1) 100 23,100 253404 H-XP3 230V (3) 95 31,700 253405 H-XP3 400V (3) 52 31,700

Power cord is not supplied. See Table 2.
Cord Specification AWG (mm2)
allen wrench, connect two power leads to L1 and L2. Connect green to ground (GND).
253400 H-40 4 (21.2), 2 wire + ground 253401 H-40 4 (21.2), 3 wire + ground 253402 H-40 8 (8.4), 4 wire + ground 253403 H-XP3 4 (21.2), 2 wire + ground 253404 H-XP3 4 (21.2), 3 wire + ground 253405 H-XP3 6 (13.3), 4 wire + ground 253407 H-40 4 (21.2), 3 wire + ground 253408 H-40 6 (13.3), 4 wire + ground 255400 H-25 4 (21.2), 2 wire + ground 255401 H-25 8 (8.4), 3 wire + ground 255402 H-25 8 (8.4), 4 wire + ground 255403 H-XP2 4 (21.2), 2 wire + ground 255404 H-XP2 6 (13.3), 3 wire + ground 255405 H-XP2 8 (8.4), 4 wire + ground 255406 H-25 4 (21.2), 2 wire + ground 255407 H-25 6 (13.3), 3 wire + ground 255408 H-25 8 (8.4), 4 wire + ground 253725 H-50 4 (21.2), 2 wire + ground 253726 H-50 4 (21.2), 3 wire + ground 253727 H-50 8 (8.4), 4 wire + ground 256505 H-50 4 (21.2), 3 wire + ground 256506 H-50 6 (13.3), 4 wire + ground

allen wrench, connect three power leads to L1, L2, and L3. Connect green to ground (GND).


c. Install agitator (L) in component B drum,
allen wrench, connect three power leads to L1, L2, and L3. Connect neutral to N. Connect green to ground (GND).
if necessary.
d. Ensure A and B inlet valves (FV) are

closed.

N
FV
Supply hoses from feed pumps should be 3/4 in. (19 mm) ID.
Some 3-phase models utilize a 3-phase motor. The motor must rotate counter- clockwise when viewed from shaft end. To reverse rotation, disconnect power and reverse power leads L1 and L2.
a. Install feed pumps (K) in component A
and B supply drums. See FIG. 1 and FIG. 2, pages 14 and 15.
A minimum feed pressure of 50 psi (0.35 MPa, 3.5 bar) is required at both feed inlet pressure gauges (FP). Maxi- mum feed pressure is 250 psi (1.75 MPa, 17.5 bar). Maintain A and B feed pressures within 10% of each other.

b. Seal component A drum and use desic-
cant dryer (M) in vent.
Setup


Do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as overpres-
BB R
sure relief valves when set to SPRAY . Lines must be open so valves can automati- cally relieve pressure when machine is oper- ating.
If circulating fluid back to the supply drums, use high pressure hose rated to withstand the maximum working pressure of this equipment.
tubes (N) in grounded, sealed waste containers (H). See FIG. 2, page 15.
The Fluid Temperature Sensor (FTS) is sup- plied. Install FTS between main hose and whip hose. See Heated Hose manual 309572 for instructions.
hose (R) to relief fittings (BA, BB) of both PRESSURE RELIEF/SPRAY valves, Route hose back to component A and B drums. See FIG. 1, page 14.
Setup · ti9880a BA

d. Connect cables (Y). Connect electrical
connectors (V). Be sure cables have slack when hose bends. Wrap cable and electrical connections with electri- cal tape.
See Heated Hose manual 309572 for detailed instructions on connecting heated hoses.

The fluid temperature sensor (C) and whip hose (D) must be used with heated hose, see page 27. Hose length, including whip hose, must be 60 ft (18.3 m) minimum.
a. Turn main power OFF .
b. Assemble heated hose sections, FTS,
and whip hose.

c. Connect A and B hoses to A and B out-
lets on Reactor fluid manifold (FM). Hoses are color coded: red for compo- nent A (ISO), blue for component B (RES). Fittings are sized to prevent con- nection errors.

Do not connect manifold to gun.

Manifold hose adapters (N, P) allow use of 1/4 in. and 3/8 in. ID fluid hoses. To use 1/2 in. (13 mm) ID fluid hoses, remove adapters from fluid manifold and install as needed to connect whip hose.
See hose manual. Pressure check for leaks. If no leaks, wrap hose and electrical connections to protect from damage.
Setup

14.Lubrication system setup
Component A (ISO) Pump: Fill ISO lube reservoir (LR) with Graco Throat Seal Liq- uid (TSL), Part 206995 (supplied).
a. Lift the lubricant reservoir (LR) out of
the bracket (RB) and remove the con- tainer from the cap.
cord. See page 25.

wire to FTS, page 27. Do not discon- nect wire or spray without whip hose.
local code.
code.
e. Solvent pails used when flushing: follow
b. Fill with fresh lubricant. Thread the res-
your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place pail on a nonconductive surface, such as paper or cardboard, which interrupts ground- ing continuity
ervoir onto the cap assembly and place it in the bracket (RB).
c. Push the larger diameter supply tube
(ST) approximately 1/3 of the way into the reservoir.
f. To maintain grounding continuity when flushing or relieving pressure, hold a metal part of spray gun firmly to the side of a grounded metal pail, then trigger gun.
d. Push the smaller diameter return tube
(RT) into the reservoir until it reaches the bottom.
Hydraulic reservoir is filled at the factory. Check fluid level before operating the first time, and weekly thereafter. See Mainte- nance, page 44.
e. The lubrication system is ready for
operation. No priming is required.
Setup

a. Check that all Setup steps are com-
plete.
b. Check that inlet screens are clean
before daily startup, page 45.
c. Check level and condition of ISO lube
daily, page 44.
d. Turn on component B agitator, if used.
e. Turn both PRESSURE RELIEF/SPRAY
valves (SA, SB) to SPRAY .
Do not operate Reactor without all covers and shrouds in place.

f. Start feed pumps.
g. Open fluid inlet valves (FV). Check for
leaks.

The Reactor is tested with oil at the fac- tory. Flush out the oil with a compatible solvent before spraying. See page 47.
Startup



This equipment is used with heated fluid, which can cause equipment surfaces to become very hot. To avoid severe burns:
Do not mix components A and B during startup. Always provide two grounded waste containers to keep component A and compo- nent B fluids separate.
h. Use feed pumps to load system. Hold
gun fluid manifold over two grounded waste containers. Open fluid valves A and B until clean, air-free fluid comes from valves. Close valves.

b. Press or to change tem-
perature scale.
c. Press to display target tempera-
tures.

d. To set heat zone target tempera-
ture, press or until display
shows desired temperature. Repeat for
and zones.
For zone only, if FTS is discon-
nected at startup, display will show hose current (0A). See step j, page 32.
Temperature Controls and Indicators, see page 18
Startup

j. Manual current control mode only:
e. Press to display actual tempera-

tures.

When in manual current control mode, moni- tor hose temperature with thermometer. Install per instructions below. Thermometer reading must not exceed 160°F (71°C). Never leave machine unattended when in manual current control mode.
Do not turn on hose heat without fluid in hoses.
f. Turn on heat zone by pressing
If FTS is disconnected or display shows diagnostic code E04, turn main power
. Preheat hose (15-60 min). Indi-
cator will flash very slowly when fluid reaches target temperature. Display shows actual fluid temperature in hose near FTS.
switch OFF then ON to
clear diagnostic code and enter manual
current control mode. display will
show current to hose. Current is not lim- ited by target temperature.

Thermal expansion can cause overpressur- ization, resulting in equipment rupture and serious injury, including fluid injection. Do not pressurize system when preheating hose.
Press or to adjust current
setting.
To prevent overheating, install hose thermometer close to gun end, within operator view. Insert thermometer through foam cover of A component hose so stem is next to inner tube. Thermometer reading will be about 20°F less than actual fluid temperature.
g. Turn on and heat zones by
pressing for each zone.
If thermometer reading exceeds 160°F
(71°C), reduce current with key.
h. Hold to view electrical currents for
each zone.
i. Hold to view heater control circuit
board temperature.
Startup

Check the pressure of each proportion- ing pump using the component A and B gauges. The pressures should be approximately equal and must remain fixed.

d. To display cycle count, press .
To clear counter, press and hold
for 3 sec.
e. Press or to change pres-
Motor Controls and Indicators, see page 21
sure scale.
a. Press to display the pressure
reading.
The pressure imbalance function (status code 24, page 43) detects conditions that can cause off-ratio spray, such as loss of feed pres- sure/supply, pump seal failure, clogged fluid inlet filter, or a fluid leak.
b. Press motor . Motor and pumps
start. Display shows system pressure.
Motor must rotate counterclockwise when viewed from shaft end. See Con- nect electrical cord, page 25.
Code 24 (pressure imbalance) is set to an alarm as the default. To change to a warning, see Reactor Repair-Parts manual 312063.
c. Adjust hydraulic pressure control until
The pressure imbalance default is factory-set at 500 psi (3.5 MPa, 35 bar). For tighter ratio error detection, select a lower value. For looser detection or to avoid nuisance alarms, select a higher value.
display shows desired fluid pressure.
a. Turn main power switch OFF .
If display pressure is greater than desired pressure, reduce the hydraulic pressure and trigger gun to reduce pressure.
Startup · ti7731a ti7732a

b. Press and hold or , then turn
main power switch ON . Display
will read dP500 for psi or dP_35 for bar.
c. Press or to select desired
pressure differential (100-999 in incre- ments of 100 psi, or 7-70 in increments of 7 bar). See TABLE 3.
100 7 600 42 200 14 700 49 300 21 800 56 400 28 900 63 *500 *35 999 69
* Factory default setting.
d. Turn main power switch OFF to
save changes.
Startup

(SA, SB) to SPRAY .
SB


pumps.

TION , until gauges show balanced pressures.
In this example, B side pressure is higher, so use the B side valve to balance pressures.

Spraying



11.Test spray onto cardboard. Adjust pressure and temperature to get desired results.
12.Equipment is ready to spray.
On impingement guns, never open fluid manifold valves or trigger gun if pres- sures are imbalanced.
If you stop spraying for a period of time, the unit will enter standby (if enabled). See page 37.
Spraying

To activate or disable standby, adjust DIP switch #3 on the motor control board. See Reactor Repair-Parts manual 312063.
If you stop spraying for a period of time, the unit will enter standby by shutting down the electric motor and hydraulic pump, to reduce equipment wear and minimize heat buildup. The ON/OFF LED and the pressure/cycle dis- play on the motor control panel will flash when in standby.
The idle time before entering standby is user-settable as follows:
The , , and heat zones
switch ON .
will not be shut off in standby.
To restart, spray off target for 2 sec. The sys- tem will sense the pressure drop and the motor will ramp up to full speed in a few seconds.
setting (5-20, in 5 minute increments). This sets the length of inactive time before the unit will enter standby.
This feature is disabled from the factory.
save changes.
Standby


10.Shut down feed pumps as required.
zones.
a. Press .
b. Trigger gun until pump A stops in the
retracted position and the pressure of both pumps bleeds down.
Shutdown · ti9883a FV

LATION . Route fluid to waste contain- ers or supply tanks. Ensure gauges drop to 0.

SB


Pressure Relief Procedure

Circulation Through Reactor
LATION .

Do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits.
SB
To circulate through gun manifold and preheat hose, see page 41.
on and heat zones by pressing
Do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as overpres-
. Do not turn on heat zone
unless hoses are already loaded with fluid.
sure relief valves when set to SPRAY . Lines must be open so valves can automati- cally relieve pressure when machine is oper- ating.
late fluid until and tempera-
tures reach targets.
pumps. Circulate fluid at lowest possible pressure until temperatures reach targets.
Fluid Circulation

10.Set PRESSURE RELIEF/SPRAY valves
(SA, SB) to SPRAY .

A B
on , , and heat zones by
pressing .
late fluid until and tempera-
tures reach targets.
Do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits.
Circulating fluid through the gun manifold allows rapid preheating of hose.
pumps. Circulate fluid at lowest possible pressure until temperatures reach targets.

R CK
Fluid Circulation

Temperature control diagnostic codes appear on temperature display.
Code Code Name Alarm Zone
01 High fluid temperature Individual
These alarms turn off heat. E99 clears auto- matically when communication is regained. Codes E03 through E06 can be cleared by
02 High current Individual
03 No current Individual
04 FTS not connected Individual
05 Board over-temperature Individual
pressing . For other codes, turn main
06 Loss of zone communication Individual
30 Momentary loss of communica- tion
power OFF then ON to clear.
99 Loss of display communication All
See repair manual for corrective action.
For hose zone only, if FTS is discon- nected at startup, display will show hose current 0A.
Diagnostic Codes · All

Motor control diagnostic codes E21 through E27 appear on pressure display.
Reactor will continue to run. Press to
There are two types of motor control codes: alarms and warnings. Alarms take priority over warnings.
clear. A warning will not recur for a predeter- mined amount of time (varies for different warnings), or until main power is turned OFF
See repair manual for corrective action.
then ON .
Alarms turn off the motor and heat zones. Turn
Code Name Alarm or
No.
main power OFF then ON to
21 No transducer (component A) Alarm
clear.
22 No transducer (component B) Alarm
23 High pressure Alarm
24 Pressure imbalance Selectable; see repair manual
Alarms can also be cleared, except for
code 23, by pressing .
27 High motor temperature Alarm
30 Momentary loss of communi- cation
Code 24 (pressure imbalance) is set to an alarm default of 500 psi (3.5 MPa, 35 bar). To change to a warning, see Reac- tor Repair-Parts manual 312063. To change the default pressure imbalance setting, see page 33.
31 Pumpline switch failure/high cycle rate
99 Loss of communication Alarm

Recommended Frequency
0 to 90°F (-17 to 32°C)
1000 hours or 12 months, whichever comes first
90°F and above (32°C and above)
500 hours or 6 months, whichever comes first


S
IM
Maintenance


The inlet strainers filter out particles that can plug the pump inlet check valves. Inspect the screens daily as part of the startup routine, and clean as required.
Use clean chemicals and follow proper stor- age, transfer, and operating procedures, to minimize contamination of the A-side screen.
* See Reactor Repair-Parts manual 312063 for fluid filter screen replacements.
Clean the A-side screen only during daily startup. This minimizes moisture contamination by immediately flushing out any isocyanate residue at the start of dispensing operations.

Check the condition of the ISO pump lubricant daily. Change the lubricant if it becomes a gel, its color darkens, or it becomes diluted with isocyanate.
Gel formation is due to moisture absorption by the pump lubricant. The interval between changes depends on the environment in which the equipment is operating. The pump lubrica- tion system minimizes exposure to moisture, but some contamination is still possible.

RT
Lubricant discoloration is due to continual seepage of small amounts of isocyanate past the pump packings during operation. If the packings are operating properly, lubricant replacement due to discoloration should not be necessary more often than every 3 or 4 weeks.
LR
To change pump lubricant:

RT
Maintenance

PRESSURE RELIEF/CIRCULATION . Flush through bleed lines (N).
Flush equipment only in a well-ventilated area. Do not spray flammable fluids. Do not turn on heaters while flushing with flammable solvents.

N
Flushing

Dimension in. (mm) A (height) 55.0 (1397) B (width) 39.6 (1006) C (depth) 18.5 (470) D (front mounting holes) 29.34 (745) E (rear mounting holes) 33.6 (853)
F (side mounting holes) 16.25 (413) G (mounting post inner diameter)0.44 (11) H (front mounting post height) 2.0 (51) J (rear mounting post height) 3.6 (92)

Side View

Detail of mounting post height, to
correctly size mounting bolts

Dimensions · ti7742a ti7743a

Category Data Maximum Fluid Working Pressure Models H-25 and H-40: 2000 psi (13.8 MPa, 138 bar) Model H-50 1 phase: 1700 psi (11.7 MPa, 11.7 bar) Model H-50 3 phase: 2000 psi (13.8 MPa, 138 bar) Models H-XP2 and H-XP3: 3500 psi (24.1 MPa, 241 bar) Fluid:Oil Pressure Ratio Models H-25 and H-40: 1.91:1 Model H-50: 1.64:1 Models H-XP2 and H-XP3: 2.79:1 Fluid Inlets Component A (ISO): 1/2 npt(f), 250 psi (1.75 MPa, 17.5 bar) maximum Component B (RES): 3/4 npt(f), 250 psi (1.75 MPa, 17.5 bar) maximum Fluid Outlets Component A (ISO): #8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter Component B (RES): #10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter Fluid Circulation Ports 1/4 npsm(m), with plastic tubing, 250 psi (1.75 MPa, 17.5 bar) maximum Maximum Fluid Temperature 190°F (88°C) Maximum Output (10 weight oil at ambient temperature)
Model H-25: 22 lb/min (10 kg/min) (60 Hz) Model H-XP2: 1.5 gpm (5.7 liter/min) (60 Hz) Model H-50: 52 lb/min (24 kg/min) (60 Hz) Model H-40: 45 lb/min (20 kg/min) (60 Hz) Model H-XP3: 2.8 gpm (10.6 liter/min) (60 Hz) Output per Cycle (A and B) Models H-25 and H-40: 0.063 gal. (0.23 liter) Model H-50: 0.073 gal. (0.28 liter) Models H-XP2 and H-XP3: 0.042 gal. (0.16 liter) Line Voltage Requirement 230V 1 phase and 230V 3 phase units: 195-264 Vac, 50/60 Hz 400V 3 phase units: 338-457 Vac, 50/60 Hz Amperage Requirement See Systems, page 3. Heater Power (A and B heaters total, no hose)
See Systems, page 3.
Hydraulic reservoir capacity 3.5 gal. (13.6 liters) Recommended hydraulic fluid Citgo A/W Hydraulic Oil, ISO Grade 46 Sound power, per ISO 9614-2 90.2 dB(A) Sound pressure, 1 m from equipment 82.6 dB(A)
Weight Units with 8.0 kW Heaters: 535 lb (243 kg)
Units with 15.3 kW Heaters (H-25/H-XP2 models):562 lb (255 kg)
Units with 15.3 kW Heaters (H-40/H-XP3/H-50 models): 597 lb (271 kg)
Units with 20.4 kW Heaters: 597 lb (271 kg) Wetted Parts Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome, fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically resistant o-rings
All other brand names or marks are used for identification purposes and are trademarks of their respective owners.
Technical Data

2000 (13.8, 138)
KEY A = H-25 at 50 Hz B = H-25 at 60 Hz C = H-40 at 50 Hz D = H-40 at 60 Hz E = H-50 at 50 Hz ❄F = H-50 at 60 Hz
Pressure in psi (MPa, bar) Pressure in psi (MPa, bar)
1500 (10.3, 103)
B
1000 (6.9, 69)
D
500 (3.4, 34)
45 (20.5)
55 (25.0)
5 (2.3)
25 (11.4) 15 (6.8)
35 (15.9)
Flow Rate in lb/min (kg/min)
❄ Pressure flow curve for model 253725 (H-50 230V 1 phase) not shown. Maximum pressure limited to 1700 psi (11.7 MPa, 11.7 bar)
3500 (24.1, 241)
KEY G = H-XP2 at 50 Hz H= H-XP2 at 60 Hz J = H-XP3 at 50 Hz K = H-XP3 at 60 Hz
3000 (20.7, 207)
2500 (17.2, 172)
2000 (13.8, 138)
1500 (10.3, 103)
1000 (6.9, 69)
500 (3.4, 34)
0 0.5 1.0 1.5 2.0 2.5 3.0 (1.9) (3.8) (5.7) (7.6) (9.5) (11.4)
Flow Rate in gal/min (liter/min)
Performance Charts

140 (78) 130 (72) 120 (67) 110 (61) 100 (56)
KEY J = 8 kW K = 12 kW L = 15.3 kW M = 20.4 kW
Delta T in degrees F (degrees C)
K
J
0 0.5 (1.9)
2.0 (7.6) 1.0 (3.8)
2.5 (9.5) 1.5 (5.7)
4.0 (15.1) 3.0 (11.4)
3.5 (13.2)
4.5 (17.0)
Flow Rate in gpm (lpm)
★Heater performance data is based on testing with 10 wt.
hydraulic oil and 230V across heater power wires.

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
Original Instructions. This manual contains English. MM 312062
www.graco.com Revision W, September 2014