AIR OPERATED, SINGLE COMPONENT DISPENSE VALVE 1K Ultra–Lite

308876L

For dispensing a wide variety of single component sealants and adhesives.

4000 psi (28 MPa, 276 bar) Maximum Fluid Working Pressure 120 psi (0.84 MPa, 8.4 bar) Maximum Air Inlet Pressure

See page 2 for Table of Contents

Part No. 965766 Stainless Steel Wetted Parts, Machine Mount Valve

Part No. 965767 Aluminum Wetted Parts, Hand–held Valve with internal air switch

Part No. 965768 Aluminum Wetted Parts, Hand–held Valve with electric switch for remote operation

Part No. 965786 Aluminum Wetted Parts, Automatic Machine Mount Valve

Part No. 243482 Stainless Steel Wetted Parts, Precision Swirl Orbiter Mounted with Nozzle Accessory

8370A

Part No. 243666 Stainless Steel Wetted Parts, PrecisionFlo Control Valve Machine Mount Valve

Model 965768 shown

Page 2 of the Graco 965768 user manual — SKIN INJECTION HAZARD
Page 2 · click to enlarge
Page 2

Table of Contents

Symbols

Warnings 2 Features 5 Installation 6 Operation/Maintenance 8 Troubleshooting 10 Service 11 Parts 16 Accessories 25 Technical Data 27 Dimensions 28 Graco Standard Warranty 30 Graco Information 30

Warning Symbol

WARNING

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

Caution Symbol

CAUTION

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.

WARNING

SKIN INJECTION HAZARD

Spray from the valve, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.

Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgi- cal treatment.

Do not point the valve at anyone or at any part of the body.

Do not stop or deflect leaks with your hand, body, glove or rag.

Be sure the valve trigger safety operates before dispensing.

Lock the valve trigger safety when you stop dispensing.

If the nozzle clogs while dispensing, fully release the trigger immediately.

Follow the Pressure Relief Procedure on page 8 whenever you: are instructed to relieve pres- sure; stop dispensing; clean, check, or service the equipment; and install or clean the nozzle.

Tighten all fluid connections before operating the equipment.

Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately. Permanently coupled hoses cannot be repaired; replace the entire hose.

Use only Graco approved hoses. Do not remove any spring guard that is used to help protect the hose from rupture caused by kinks or bends near the couplings.

Page 3 of the Graco 965768 user manual — INSTRUCTIONS
Page 3 · click to enlarge
Page 3

WARNING

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

INSTRUCTIONS

This equipment is for professional use only.

Read all instruction manuals, tags, and labels before operating the equipment.

Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor.

Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not exceed the maximum working pressure stated on the equipment or in the Technical Data for your equipment. Do not exceed the maximum working pressure of the lowest rated component in your system.

Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

Do not use hoses to pull equipment.

Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 180F (82C) or below –40F (–40C).

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

Never use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in this equipment. Such use could result in a serious chemical reaction, with the possibility of explosion, which could cause death, serious injury, and/or substan- tial property damage.

Page 4 of the Graco 965768 user manual — TOXIC FLUID HAZARD
Page 4 · click to enlarge
Page 4

WARNING

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

Ground the equipment and the object being sprayed. Refer to Grounding on page 6.

If there is any static sparking or you feel an electric shock while using this equipment, stop dis- pensing immediately. Do not use the equipment until you identify and correct the problem.

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being dispensed.

Keep the dispense area free of debris, including solvent, rags, and gasoline.

Extinguish all open flames or pilot lights in the dispense area.

Do not smoke in the dispense area.

Do not turn on or off any light switch in the dispense area while operating or if fumes are present.

Do not operate a gasoline engine in the dispense area.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

Page 5 of the Graco 965768 user manual — Features
Page 5 · click to enlarge
Page 5

Features

Adjustable forward travel to reduce material surge when valve opens Severe-Duty needle and seat for longer operating life Lubricated packings for longer seal life Lightweight construction reduces operator/machinery fatigue

Compact size for small X–Y tables, working areas, and robots Handle kit provides easy conversion from automatic to manual usage Stainless steel housing to handle most materials

4 Control Configurations 1. 1/8 npt(f) ported manifold block 2. Direct solenoid mount with speed control 3. Handle kit with 4-way air valve 4. Handle kit with electric switch

Graco 965768 — Features diagram (page 5)
Fig. 1 · Features

Travel adjustment (Model 965766, 965767, 965768, and 965786 only)

Accessory flow control fittings to adjust open/close speed.

Shaft is free to align

Hard chrome/stainless steel shaft

Urethane u-cup secondary seals

Self centering plastic bearing

Hardened stainless steel needles

Aluminum or stainless wetted housings

Reversible carbide seat for severe duty

Snuff back restrictor ring (13) is removable for high flow applications.

Fig. 1 8374A

Show 4 more labels / short text on this page
Replaceable nylon bearings · Divorced air section · Proven primary seals ·
Page 6 of the Graco 965768 user manual — SKIN INJECTION HAZARD
Page 6 · click to enlarge
Page 6

Installation

NOTES:

Fluid supply container: ground according to your local code.

Reference numbers and letters in parentheses in the text refer to the callouts in the figures and drawings.

Flammable liquids in the spray area: must be in approved, grounded containers. Do not store more than the quantity needed for one shift.

Accessories are available from your Graco representative. If you supply your own accessories, be sure they are adequately sized and pressure-rated to meet the system’s requirements.

All solvent pails used when flushing: ground according to local code. Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.

Grounding

WARNING

To maintain grounding continuity when flushing or relieving pressure, hold a metal part of the valve firmly to the side of a grounded metal pail, then trigger the valve.

FIRE AND EXPLOSION HAZARD To reduce the risk of fire, explosion, and serious injury, proper electrical ground- ing of every part of your system is es- sential. Read the warning section Fire and Explosion Hazard on page 4, and follow the grounding instructions below.

How to Use the Valve Trigger Safety

WARNING

The following grounding instructions are minimum requirements for a basic dispensing system. Your system may include other equipment or objects which must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Your system must be connected to a true-earth ground.

SKIN INJECTION HAZARD

To prevent accidental triggering of the gun and reduce the risk of a serious inju- ry, including fluid injection or splashing in the eyes or on the skin, lock the gun trigger safety when you stop dispensing.

1. If you are using one of the hand-held versions of the valve, lock the valve trigger safety by turning the latch to a right angle with the gun body. See Fig. 2.

Pump: ground the pump by connecting ground wire and clamp as described in your separate pump instruction manual.

Air compressors and hydraulic power supplies: ground the equipment according to the manufacturer’s recommendations.

2. To unlock the valve trigger safety, push the latch out and turn it parallel with the gun body.

Fluid hoses: use only grounded fluid hoses with a maximum of 500 feet (150 m) combined hose length to ensure grounding continuity. Check the electrical resistance of your fluid hoses at least once a week. If your hose does not have a tag on it which specifies the maximum electrical resistance, contact the hose supplier or manufacturer for the maximum electrical resistance limits, replace the hose immediately.

Dispensing valve: ground the valve by connecting it to a properly grounded fluid hose and pump.

Locked Unlocked · ·

Page 7 of the Graco 965768 user manual — 8370A
Page 7 · click to enlarge
Page 7

Installation

Connections

Install a remote 4-way air control valve to operate the valve. Connect an open air signal air line to the 1/8 npt(f) OPEN port. Connect a close air signal air line to the 1/8 npt(f) CLOSE port.

The fluid inlet is 1/4 npt(f).

The fluid outlet is 1/4 npt(f) or 3/4–16 unf(m).

Air inlets are 1/8 npt(f).

Air Switch Hand Held Valve

See Accessories, page 25, to order air control valves and tubing.

This valve has a single air inlet and an internal 4-way spool valve, which directly operates the air piston. Connect the air line to the 1/8 npt(f) air inlet.

Electric Switch Hand Held Valve

Install a remote 4-way air control valve to operate the valve. Connect an OPEN air signal air line to the 1/8 npt(f) port on the side of the valve. Connect a CLOSE air signal air line to the 1/8 npt(f) port on the opposite side of the valve. Wire the normally open valve switch to the system control.

Solder to terminals in cable connectors as shown in Detail A.

Normally open, momentary contact switch.

Ground connection.

Electric Switch Hand Held Valve shown

8370A

Machine Mount Valve · Detail A ·

Page 8 of the Graco 965768 user manual — Machine Mount Valve
Page 8 · click to enlarge
Page 8

Operation

Electric Switch Hand Held Valve

WARNING

Be sure the air supply lines are connected correctly to the OPEN and CLOSE valve air ports.

COMPONENT RUPTURE HAZARD To reduce the risk of over-pressurization, which can cause component rupture and serious injury, never exceed 3000 psi (21 MPa, 207 bar) fluid pressure, or 120 psi (0.84 MPa, 8.4 bar) air pressure to the valve.

To open or close the valve and maintain the open or closed status, a minimum of 40 psi (280 kPa, 2.8 bar) air pressure must be supplied and maintained at the OPEN or CLOSE port.

Pressure Relief Procedure

The trigger only activates the electrical switch in the handle, which turns the remote solenoid on and off.

WARNING

Trigger the gun to turn the solenoid on. Release the trigger to turn the solenoid off.

SKIN INJECTION HAZARD

The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

Machine Mount Valve

Be sure the air supply lines are connected correctly to the OPEN and CLOSE valve air ports.

To open or close the valve and maintain the open or closed status, a minimum of 40 psi (280 kPa, 2.8 bar) air pressure must be supplied and maintained at the OPEN or CLOSE port.

are instructed to relieve the pressure stop dispensing check or service any of the system equipment install or clean the nozzle

To open the valve:

1. Apply air pressure to the OPEN air port on the valve, and remove air pressure from the CLOSE air port on the valve.
1. Shut off the air to the dispense valve, if applicable.
2. Maintain air pressure on the OPEN air port to keep the valve open.
2. Shut off the air to the supply pumps.
3. Close the bleed-type master air valve (required in your system).

To close the valve:

1. Apply air pressure to the CLOSE air port on the valve, and remove air pressure from the OPEN air port on the valve.
4. Hold a metal part of the valve firmly to the side of a grounded metal pail, and trigger the dispense valve to relieve pressure.
2. Maintain air pressure to the CLOSE air port to keep the valve closed.
5. Open the fluid drain valve (required in your system), having a grounded metal container ready to catch the drainage.
6. Leave the fluid drain valve open until you are ready to dispense again.

If you suspect that the dispense needle or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the needle retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the needle or hose.

Page 9 of the Graco 965768 user manual — Preventative Maintenance
Page 9 · click to enlarge
Page 9

Operation

Air Switch Hand Held Valve

The valve is at full stroke when the hex nut (44) is at the end of the adjustment shaft (42).

The valve operation is such that there are only two valve conditions: either fully open or fully closed.

Adjusting the nut (44) on the shaft (42) towards the valve, or clockwise, will reduce the stroke length.

The valve is opened and closed by the internal air control valve. Trigger the gun to open the valve. Release the trigger to close the valve.

Adjusting the nut away from the valve, or counterclockwise, will lengthen the stroke.

Shaft Stroke Adjustment (Models 965766, 965767, 965768, and 965786 only)

3. Tighten the hex nut (44) to the adjustment nut (43) to set the adjustment.

Adjust the shaft stroke to balance the valve between “snuff-back” and “push-out”.

A long stroke will give maximum snuff-back but it may cause push-out when the valve opens.

Shortening the stroke of the shaft will minimize the material pushed out when the valve opens and will also increase the material back pressure through the valve.

To adjust the shaft stroke:

1. Loosen the hex nut (44) from the adjustment nut (43).
2. Adjust the nut (44) along the adjustment shaft (42) to the desired position.

Fig. 4

Maintenance

Preventative Maintenance

To grease the valve:

1. Remove the grease fitting from one side of the gun.

There is a grease filled secondary seal/bearing area on the valve shaft. Every 10,000 cycles, or twice each month, new grease should be flushed across this area. Each valve has two flush grease fittings. A small grease gun is provided with each valve.

2. Pump grease (Part No. 115982) across the valve until clear grease comes out of the other side.
3. Reinstall the grease fitting.

Shorten Lengthen ·

Page 10 of the Graco 965768 user manual — SKIN INJECTION HAZARD
Page 10 · click to enlarge
Page 10

Troubleshooting

1. Relieve the pressure.

WARNING

2. Check all possible causes to the problem before disassembling the pump.

SKIN INJECTION HAZARD

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

PROBLEMCAUSESOLUTION Valve does not openInsufficient air pressureTurn on or turn up air pressure. Air not exhausted from behind air cylinder pistonUse four-way, relieving-type air valve operator. Shaft adjustment too far closedAdjust the shaft stroke as instructed on page 9. Valve does not close (leaks)Insufficient air pressureTurn on or turn up air pressure. Air not exhausted from behind air cylinder pistonUse four-way, relieving-type air valve operator. Blockage between needle and seatRemove and clean needle and seat. Bad or missing gasket between seat and housingReplace gasket (38). Needle worn outReplace needle and seat. Higher than normal back-pressureNosepiece plugging upRemove and clean.

Page 11 of the Graco 965768 user manual — Disassembly
Page 11 · click to enlarge
Page 11

Service

12. Remove the pin (7), o-ring (9), and piston o-ring (6).

WARNING

SKIN INJECTION HAZARD

13. Use a 1/4 in. pin punch to knock out the bearings (5) and o-rings (4).

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

Air Switch Handle (if equipped)

1. Remove the trigger (56).

Disassembly

2. Loosen the set screw above the trigger safety. Pull off the handle (55).
1. Relieve all air and fluid pressure .
3. Remove the four retaining screws (60). Pull the housing (50) and gasket (30) away from the air cylinder (1).
2. Disconnect the valve from the system.
3. Remove the four nosepiece screws (15), and pull the nosepiece (40) away from the valve. Remove the snuff-back ring (41). See Fig. 5, page 14.
1. Unscrew the stem guide (58).
4. Use an 1/8 in. pin punch in the needle hole (A) to unscrew the needle (27). If the shaft (3) spins, insert a dowel pin in the shaft hole (B) to hold it steady, then unscrew the needle (27).
2. Remove the trigger pin (59), o-ring (57), spool (49), spacers (51, 52), o-rings (46, 48) and spring (47).
5. Remove the seat (25), gasket (38), and o-ring (39).
3. Remove the bushing (53) from the housing (50) with the screw (54).
4. Remove the screws (60) and lock-washers (61) from the air cylinder (1).
6. Remove the two fluid housing screws (23) and remove the fluid housing (26). Remove the primary fluid seal (22) from the fluid housing (26).

Electric Switch Handle (if equipped)

7. Pull the bearing/lube housing (19) from the air cylinder (1). Remove the bearing (21), bearing o-ring (16), and secondary fluid seal (20). Remove the grease fittings (18).
1. Disconnect the power from the gun.
2. The switch, housing, and cable are not repairable. Replace these parts as a complete assembly.
3. Remove the trigger (56).
8. Remove the C-clip (12) from the back of the air cylinder (1). Push the shaft (3) into the air cylinder to dislodge the air cylinder cap (11). Remove the cap o-ring.
4. Loosen the setscrew above the trigger safety. Pull off the handle (55).
9. Remove the internal C-clip (12). Push the shaft (3) to dislodge the piston (10) assembly from the air cylinder (1).
5. Remove the four manifold retaining screws (60). Pull the housing (50) and gasket (30) away from the air cylinder (1).
10. Remove the adjustment nut (44) from the shaft (3).
6. Remove the bushing (53) from the housing (50) with the screw (54).
11. Remove the adjustment shaft (42) from the shaft (3).
7. Remove the screws (60) and lock-washers (61) from the air cylinder (1).

Air Valve ·

Page 12 of the Graco 965768 user manual — Reassembly
Page 12 · click to enlarge
Page 12

Service

Reassembly

1. Lubricate the bearing (21), o-ring (16) and cup seal (20). Put the o-ring (16) on the bearing. Carefully insert the seal (20) into the bearing recess, with the lips of the o-ring facing into the bearing. Be careful not to damage the seal lips.
1. Lubricate the shaft o-rings (4) and the bearings (5) with grease supplied in the repair kit. Insert o-rings into the air cylinder (1) and air cap (11) cavities. See Fig. 5.
2. Push the bearing (21) seal end first into the housing (19). Be sure that the grease hole in the side of the bearing lines up with the grease ports in the housing (19).
2. Press the bearings (5) flush into the air cylinder housing and air cap, trapping the o-rings (4).
3. Lubricate and reassemble the piston assembly; piston (10), o-ring (9), dowel pin (7), adjustment shaft (42), o-ring (6), and shaft (3). Use Loctite Primer N7649 and Loctite TL242, 243, or equivalent (“blue” Loctite) when assembling the adjustment shaft (42). Tighten the shaft to 15–20 in–lb (1.7–2.2 N m). The shaft (3) should hang with some play to be self-aligning in the bearing.
3. Holding the bearing (21) in place, push the bearing assembly over the shaft (3).
4. Lubricate the main fluid seal (22) and its cavity in the housing (26). Carefully press the seal, lip-first, into the housing.
5. Push the housing (26) and seal (22) over the shaft (3) and up against the bearing housing.
4. Lubricate the air cylinder (1) ID with the grease supplied. Push the piston (10) assembly into the air cylinder.
6. Apply anti–seize lubricant (Loctite 56765 or equivalent) to the fluid housing screws (23) and loosely install the screws to retain the housings. Do not tighten the screws yet.
5. Orient the air inlet manifold (2) (if used) as shown. Match the gasket openings to the air ports.
7. Insert the gasket (38) and seat (25). These items are reversible and can be installed in either direction.
8. Use Loctite Primer N7649 and Loctite TL242, 243, or equivalent (“blue” Loctite) when assembling the needle (27) and tighten to 15–20 in–lb (1.7–2.2 N m).
9. Apply air pressure to the CLOSE port, or to the pneumatic trigger valve if installed. This will align the shaft, seal, and bearing. Tighten the fluid housing screws (23) oppositely and evenly to 40–45 in-lbs (4.5–5 N m).
10. Install the nosepiece (40) with the PTFE o-ring (39), screw (15), and snuff-back ring (41), if used. The snuff-back ring has an internal bevel on one end which faces into the nosepiece. Tighten the nosepiece screws to 15–20 in-lbs (1.7–2.2 N m).

Fluid Section · Air Cylinder Section ·

Page 13 of the Graco 965768 user manual — Service
Page 13 · click to enlarge
Page 13

Service

Air Valve (if equipped)

8. Orient the gasket (30) to the holes on the air cylinder (1). Screw the air valve assembly to the cylinder with the screws (60) and lock-washers (61). TIghten the screws evenly to 15–20 in-lbs (1.7–2.2 N m).
1. Insert the spring (51) into the housing (50).
2. Lubricate and install an o-ring (46) into the housing.
3. Install a spacer (52), internal bevel first, into the housing.
9. Screw the bushing (53) to the housing (50) with the screw (54). Tighten the screw to 140–150 in-lbs (15.8–16.9 N m).
4. Lubricate and install two o-rings (46) and the spacer (51).
10. Attach the handle (55) with the setscrew.
11. Attach the trigger (56) with the grease fittings (18).
5. Lubricate and install a spacer (52) with the internal bevel out, and o-ring (46).
12. Test that the trigger safety works properly.
6. Lubricate and install o-rings (48) on the spool (49). Insert the spool with the nub facing out.
1. The switch, housing, and cable are not repairable. Replace these parts as a complete assembly.
7. Lubricate the pin (59) and insert it into the guide (58). Screw the guide with o-ring (57) into the housing. Tighten it to 60–70 in-lbs (6.8–7.9 N m).
2. The switch, housing, and cable assembly are not user serviceable and must be replaced as an assembly.

Electric Switch ·

Page 14 of the Graco 965768 user manual — Service
Page 14 · click to enlarge
Page 14

Service

Graco 965768 — Service diagram (page 14)
Fig. 2 · Service

6 5 3 4 28, 29 20 21 22 39

2 9 10 16

Graco 965768 — Service diagram (page 14)
Fig. 3 · Service

Tighten to 15–20 in-lb (1.7–2.2 Nm). The shaft should hang with some play to be self-aligning in the bearing.

Screw the bushing (53) to the housing (50) with screw (54). Tighten to 140–150 in-lbs (15.8–16.9 Nm).

Apply Loctite Primer N7649 and Loctite TL242, 243, or equivalent (“blue” Loctite).

Tighten oppositely and evenly to 40–45 in-lbs (4.5–5 Nm).

26 19 18 ·

Page 15 of the Graco 965768 user manual — Notes
Page 15 · click to enlarge
Page 15

Notes

Page 16 of the Graco 965768 user manual — 8371A
Page 16 · click to enlarge
Page 16

Parts

Graco 965768 — Parts diagram (page 16)
Fig. 4 · Parts

8371A

28, 29 ·

Page 17 of the Graco 965768 user manual — Parts
Page 17 · click to enlarge
Page 17

Parts

Model 965766 Machine Mount Valve Stainless steel wetted parts

Model 243482 Orbiter Mounted Valve Stainless steel wetted parts

Model 965786 Automatic Machine Mount Valve Aluminum wetted parts

Model 243666 PrecisionFlo Control Valve Stainless steel wetted parts

Ref. No.

Part No. Description Qty.

Ref. No.

Part No. Description Qty.

1 626702 HOUSING, air cylinder 1 2 626069 MANIFOLD, air control 1 3 626068 SHAFT, air cylinder 1 4* 156454 O-RING, 010 buna-n 2 5* 551181 BEARING, air cylinder 2 6* 154662 O-RING, 222 buna-n 2 7* 552164 DOWEL PIN 1 9* 157628 O-RING, 006 buna-n 1 10 626703 PISTON, air cylinder 1 11 626704 CAP, air cylinder CAP, air cylinder; Models 965766 and 965786 only

30* 626057 GASKET, air cylinder 1 31 104459 SCREW, 10–32 x 1.75 4 35* 551186 GREASE, 3 oz. tube (not shown)

36 115982 GUN, grease (not shown) 1 37 551187 COUPLER, flush grease (not shown)

38*† 171860 GASKET, seat 1 39*† 104319 O-RING, 014 PTFE 1 40 626732 NOSEPIECE, stainless steel; Models 965766 and 243666 only

196018 CAP, air cylinder; Models 243482 and 243666 only 1

626707 NOSEPIECE; aluminum; Model 965786 only

12 552163 CLIP, internal 1.75 2 15 104371 SCREW, 10–32 x 0.375 4 16*† 103610 O-RING, 014 fluoroelastomer

195957 NOSEPIECE; stainless steel; Model 243482 only

41* 626060 RING, snuff-back 1 42 626708 SHAFT, adjustment Models 965766 and 965786 only 1

18 551188 FLUSH GREASE FITTING 2 19 626705 LUBE HOUSING 1 20*† 551191 U-CUP, urethane/EPR 1 21* 626064 BEARING, lube 1 22*† 551190 U-CUP, Polymite/EPR 1 23 103926 SCREW, 1/4–20 x 2.25 2 25* 185467 SEAT, C2 carbide 1 26 626731 HOUSING, fluid; stainless steel; Model 965766 and 243282 only

43 626709 NUT, adjustment Models 965766 and 965786 only 1

44 100166 NUT, full hex, 10–32 Mod- els 965766 and 965786 only

45 102920 NUT, jam, 10–32 Models 243482 and 2436666 only 1

* Included in Rebuild Kit 570268.

† Included in Section Seal Kit 570267.

626706 HOUSING, fluid; aluminum; Model 965786 only

27* 626062 NEEDLE, hardened stain- less steel

Replacement Instruction and Warning Labels are

available at not cost.

28 188377 LABEL, skin injection haz- ard

Use Loctite Primer N7649 and Loctite TL242, 243, or equivalent (“blue” Loctite) when assembling this part.

29 188378 LABEL, read instruction manual

Use anti–seize lubricant (Loctite 56765 or

equivalent) when assembling 965766 and 965786. Use Loctite TL242, 243, or equivalent (“blue” Loctite) when assembling 243482 and 243666.

Page 18 of the Graco 965768 user manual — 8372A
Page 18 · click to enlarge
Page 18

Parts

Graco 965768 — Parts diagram (page 18)
Fig. 5 · Parts
Graco 965768 — Parts diagram (page 18)
Fig. 6 · Parts

8372A

(965767 only) · 46 48 49 ·

Page 19 of the Graco 965768 user manual — Disassembly
Page 19 · click to enlarge
Page 19

Service

6. Remove the two fluid housing screws (23) and remove the fluid housing (26). Remove the primary fluid seal (22) from the fluid housing (26).

WARNING

SKIN INJECTION HAZARD

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

7. Pull the bearing/lube housing (19) from the air cylinder (1). Remove the bearing (21), bearing o-ring (16), and secondary fluid seal (20). Remove the grease fittings (18).

Disassembly

8. Remove the C-clip (12) from the back of the air cylinder (1). Push the shaft (3) into the air cylinder to dislodge the air cylinder cap (11). Remove the cap o-ring.
1. Relieve all air and fluid pressure .
2. Disconnect the valve from the system.
9. Remove the internal C-clip (12). Push the shaft (3) to dislodge the piston (10) assembly from the air cylinder (1).
3. Remove the four nosepiece screws (15), and pull the nosepiece (40) away from the valve. Remove the snuff-back ring (41). See Fig. 5, page 14.
10. Remove the pin (7), o-ring (9), and piston o-ring (6).
4. Use an 1/8 in. pin punch in the needle hole (A) to unscrew the needle (27). If the shaft (3) spins, insert a dowel pin in the shaft hole (B) to hold it steady, then unscrew the needle (27).
11. Use a 1/4 in. pin punch to knock out the bearings (5) and o-rings (4).
5. Remove the seat (25), gasket (38), and o-ring (39).

Page 20 of the Graco 965768 user manual — Reassembly
Page 20 · click to enlarge
Page 20

Service

Reassembly

1. Lubricate the bearing (21), o-ring (16) and cup seal (20). Put the o-ring (16) on the bearing. Carefully insert the seal (20) into the bearing recess, with the lips of the o-ring facing into the bearing. Be careful not to damage the seal lips.
1. Lubricate the shaft o-rings (4) and the bearings (5) with grease supplied in the repair kit. Insert o-rings into the air cylinder (1) and air cap (11) cavities. See Fig. 5.
2. Push the bearing (21) seal end first into the housing (19). Be sure that the grease hole in the side of the bearing lines up with the grease ports in the housing (19).
2. Press the bearings (5) flush into the air cylinder housing and air cap, trapping the o-rings (4).
3. Lubricate and reassemble the piston assembly; piston (10), o-ring (9), dowel pin (7), o-ring (6), and shaft (3). Tighten the jam nut (45) to 15–20 in-lb (1.7–2.2 N m). The shaft (3) should hang with some play to be self-aligning in the bearing.
3. Holding the bearing (21) in place, push the bearing assembly over the shaft (3).
4. Lubricate the main fluid seal (22) and its cavity in the housing (26). Carefully press the seal, lip-first, into the housing.
4. Lubricate the air cylinder (1) ID with the grease supplied. Push the piston (10) assembly into the air cylinder.
5. Push the housing (26) and seal (22) over the shaft (3) and up against the bearing housing.
5. Orient the air inlet manifold (2) (if used) as shown. Match the gasket openings to the air ports.
6. Apply Loctite Primer N7649 and Loctite TL242, 243, or equivalent (“blue” Loctite) to the fluid housing screws (23) and loosely install the screws to retain the housings. Do not tighten the screws yet.
7. Insert the gasket (38) and seat (25). These items are reversible and can be installed in either direction.
8. Apply Loctite Primer N7649 and Loctite TL242, 243, or equivalent (“blue” Loctite) to needle (27) and tighten to 15–20 in–lb (1.7–2.2 N m).
9. Apply air pressure to the CLOSE port, or to the pneumatic trigger valve if installed. This will align the shaft, seal, and bearing. Tighten the fluid housing screws (23) oppositely and evenly to 40–45 in-lbs (4.5–5 N m).
10. Install the nosepiece (40) with the PTFE o-ring (39), screw (15), and snuff-back ring (41), if used. The snuff-back ring has an internal bevel on one end which faces into the nosepiece. Tighten the nosepiece screws to 15–20 in-lbs (1.7–2.2 N m).

Fluid Section · Air Cylinder Section ·

Page 21 of the Graco 965768 user manual — Parts
Page 21 · click to enlarge
Page 21

Parts

Graco 965768 — Parts diagram (page 21)
Fig. 7 · Parts

6 5 3 4 28, 29 20 21 22 39 23 40 15

Tighten oppositely and evenly to 40–45 in-lbs (4.5–5 Nm).

Tighten to 15–20 in lbs (17–22 Nm)

Apply Loctite Primer N7649 and Loctite TL242, 243, or equivalent (“blue” Loctite).

Page 22 of the Graco 965768 user manual — 8371A
Page 22 · click to enlarge
Page 22

Parts

Graco 965768 — Parts diagram (page 22)
Fig. 8 · Parts

8371A

28, 29 ·

Page 23 of the Graco 965768 user manual — Parts
Page 23 · click to enlarge
Page 23

Parts

Model 965767 Hand Held Valve with Pneumatic Trigger Aluminum wetted parts See page 16 for illustration of items 1–44. See page 18 for illustration of items 46–62.

Ref. No.

Part No. Description Qty.

Ref. No.

Part No. Description Qty.

1 626702 HOUSING, air cylinder 1 3 626068 SHAFT, air cylinder 1 4* 156454 O-RING, 010 buna-n 2 5* 551181 BEARING, air cylinder 2 6* 154662 O-RING, 222 buna-n 2 7* 552164 DOWEL PIN 1 9* 157628 O-RING, 006 buna-n 1 10 626703 PISTON, air cylinder 1 11 626704 CAP, air cylinder 1 12 552163 CLIP, internal 1.75 2 16*† 103610 O-RING, 014 fluoroelastomer

40 626707 NOSEPIECE, aluminum 1 41* 626060 RING, snuff-back 1 42 626708 SHAFT, adjustment 1 43 626709 NUT, adjustment 1 44 100166 NUT, full hex, 10–32 1 46 106559 O-RING, No. 905 fluoroelastomer

47 106561 SPRING 1 48 106560 O-RING, 007 fluoroelastomer

49 178651 SPOOL, 4-way 1 50 626056 HOUSING, air valve 1 51 178652 SPACER, u-shape 1 52 178653 SPACER, air valve 2 53 626055 BUSHING, handle 1 54 551204 SCREW, 3/8–16 x 3/4 1 55 626075 HANDLE 1 56 626083 TRIGGER 1 57 106551 O-RING, 0.5 x 0.6 fluoroelastomer

18 551188 FLUSH GREASE FITTING 2 19 626705 LUBE HOUSING 1 20*† 551191 U-CUP, urethane/EPR 1 21* 626064 BEARING, lube 1 22*† 551190 U-CUP, Polymite/EPR 1 23 103926 SCREW, 1/4–20 x 2.25 2 25* 185467 SEAT, C2 carbide 1 26 626706 HOUSING, fluid; aluminum 1 27* 626062 NEEDLE, hardened stain- less steel

58 178654 GUIDE, stem 1 59 626053 PIN, trigger 1 60 119156 SCREW, 10–32 x 0.8125 4 61 100020 WASHER, lock, #10 2 62 104765 PLUG, pipe, headless, 1/8 npt (not shown) 1

28 188377 LABEL, skin injection haz- ard

29 188378 LABEL, read instruction manual

30* 626057 GASKET, air cylinder 1 31 104459 SCREW, 10–32 x 1.75 4 35* 115982 GREASE, 3 oz. tube (not shown)

* Included in Rebuild Kit 570268.

† Included in Section Seal Kit 570267.

36 551189 GUN, grease (not shown) 1 37 551187 COUPLER, flush grease (not shown)

Replacement Instruction and Warning Labels are

available at no cost.

38*† 171860 GASKET, seat 1 39*† 104319 O-RING, 014 PTFE 1

Loctite Primer N7649 and Loctite TL242, 243, or equivalent (“blue” Loctite) should be used when installing this part.

Anti–seize lubricant (Loctite 56765 or equivalent)

should be used when installing this part.

Page 24 of the Graco 965768 user manual — Parts
Page 24 · click to enlarge
Page 24

Parts

Model 965768 Hand Held Valve with Electric Switch Aluminum wetted parts See page 16 for illustration of items 1–44. See page 18 for illustration of items 53–63.

Ref. No.

Part No. Description Qty.

Ref. No.

Part No. Description Qty.

1 626702 HOUSING, air cylinder 1 3 626068 SHAFT, air cylinder 1 4* 156454 O-RING, 010 buna-n 2 5* 551181 BEARING, air cylinder 2 6* 154662 O-RING, 222 buna-n 2 7* 552164 DOWEL PIN 1 9* 157628 O-RING, 006 buna-n 1 10 626703 PISTON, air cylinder 1 11 626704 CAP, air cylinder 1 12 552163 CLIP, internal 1.75 2 15 104371 SCREW, 10–32 x 0.375 4 16*† 103610 O-RING, 014 fluoroelastomer

36 551189 GUN, grease (not shown) 1 37 551187 COUPLER, flush grease (not shown)

38*† 171860 GASKET, seat 1 39*† 104319 O-RING, 014 PTFE 1 40 626707 NOSEPIECE, aluminum 1 41* 626060 RING, snuff-back 1 42 626708 SHAFT, adjustment 1 43 626709 NUT, adjustment 1 44 100166 NUT, full hex, 10–32 1 53 626055 BUSHING, handle 1 54 551204 SCREW, 3/8–16 x 3/4 1 55 626075 HANDLE 1 56 626083 TRIGGER 1 60 119156 SCREW, 10–32 x 0.8125 4 61 100020 WASHER, lock, #10 2 63 949706 SWITCH ASSEMBLY 1

18 551188 FLUSH GREASE FITTING 2 19 626705 LUBE HOUSING 1 20*† 551191 U-CUP, urethane/EPR 1 21* 626064 BEARING, lube 1 22*† 551190 U-CUP, Polymite/EPR 1 23 103926 SCREW, 1/4–20 x 2.25 2 25* 185467 SEAT, C2 carbide 1 26 626706 HOUSING, fluid; aluminum 1 27* 626062 NEEDLE, hardened stain- less steel

* Included in Rebuild Kit 570268.

† Included in Section Seal Kit 570267.

Replacement Instruction and Warning Labels are

available at not cost.

28 188377 LABEL, skin injection haz- ard

Loctite Primer N7649 and Loctite TL242, 243, or equivalent (“blue” Loctite) should be used when installing this part.

29 188378 LABEL, read instruction manual

30* 626057 GASKET, air cylinder 1 31 104459 SCREW, 10–32 x 1.75 4 35* 115982 GREASE, 3 oz. tube (not shown)

Anti–seize lubricant (Loctite 56765 or equivalent)

should be used when installing this part.

Page 25 of the Graco 965768 user manual — Optional Main Fluid Needle Packings (22)
Page 25 · click to enlarge
Page 25

Accessories

Plastic Tube Fittings to Connect Air Signals

Tube OD 1/8 NPT (M) Straight 1/8 NPT (M) 90º Swivel Tube Tee

1/8 in. 5/32 in. 1/4 in.

598329 104172 513826 598140 597151

Tube OD 1/4 NPT (M) Straight 1/4 NPT (M) 90º Swivel

5/32 in. 1/4 in. 598252 104165 598327 C19391

Plastic Tubing for Air Signal Lines

4-Way Solenoids and Solenoid Accessories

Part No. Description

513063 1/8 in. O.D. Nylon 514607 5/32 in. O.D. Nylon C12509 1/4 in. O.D. Nylon

To direct mount solenoid to 1K Ultra–Lite Valve.

551316 120 Volt ac Solenoid

Air Signal Accessories

For use with 626144 Manifold.

551201 Air Cylinder Speed Control 90 Fitting

551317 24 Volt dc Solenoid

1/8 npt(f) inlet, 1/8 npt(m) outlet

For use with 626144 Manifold.

Mount on CLOSE port to control opening speed for soft start. Mount on OPEN port to control closing speed for less snuff–back.

551347 120 Volt ac Solenoid

Remote mount, 1/8 npt (f) ports

104661 Quick Exhaust Valve

551348 24 Volt dc Solenoid

1/8 npt(f) inlet and outlet, 1/4 npt(f) exhaust

Remote mount, 1/8 npt(f) ports

Used to speed up opening or closing action of the 1K Ultra–Lite Valve

551349 120 Volt ac Din Plug

With screw terminals for above solenoids

104632 Pump Pilot Valve

1/2 npt (f) line ports, 1/8 npt(f) pilot port

551350 24 Volt dc Din Plug

With screw terminals for above solenoids

3–way air piloted air valve to turn air powered proportioning pump on with hand gun signal.

Optional Main Fluid Needle Packings (22)

Part No. Description

551192 Urethane U–Cup with EPDM o–ring spreader 551193 Reinforced PTFE U–Cup with 302 stainless steel spreader

551203 514435 111167 · 626144 Manifold ·

Page 26 of the Graco 965768 user manual — 8462A
Page 26 · click to enlarge
Page 26

Accessories

Fluid Nozzles

168683 Nozzle Bushing

Zinc-plated steel nozzles, 1/8 npt*

Zinc-plated steel, 1/8 npt

Kits

Part No. Orifice Length

607665 0.125 in. (3.17 mm) 2 in. (51 mm)

161505 0.09 in. (2.28 mm) 2 in. (51 mm)

Pneumatic 4–way valve with housing, handle, and trigger and other parts necessary to convert 965766 or 965786 to a hand held valve.

164799 0.055 in. (1.39 mm) 2-1/8 in. (54 mm)

* Requires a 1/8 npt(f) bushing. Order 168683 Nozzle Bushing.

Electric switch style handle kit to convert 965766 or 965786 to a hand held valve.

Nozzles for use with 188253 flange nut.

With Polymite main packing (standard)

8462A

With Polymite main packing (standard)

Part No. Orifice Length

C00005 0.187 in. (4.75 mm) 1.656 in. (42 mm)

C00007 0.093 in. (2.36 mm) 2 in. (51 mm)

With PTFE main packing (optional)

C00008 0.250 in. (2.28 mm) 2 in. (51 mm)

C00009 0.172 in. (4.37 mm) 2 in. (51 mm)

With PTFE main packing (optional)

C00010 0.062 in.(1.57 mm) 2 in. (51 mm)

C00011 0.375 in. (9.53 mm) 2 in. (51 mm)

C00012 0.156 in. (3.96 mm) 2 in. (51 mm)

C00013 0.046 in. (1.17 mm) 2 in. (51 mm)

C00014 0.031 in. (0.79 mm) 2 in. (51 mm)

C00015 0.156 in. (3.96 mm) 1.812 in. (46 mm)

512135 Plastic Fluid Nozzle

1/4 npt, 0.062 in. (1.57 mm) orifice, 2-1/2 in. (63.5 mm) long

Show 7 more labels / short text on this page
949631 Conversion Kit · 949632 Conversion Kit · 570267 Seal Kit · 570268 Rebuild Kit · 570299 Seal Kit · 570300 Rebuild Kit ·
Page 27 of the Graco 965768 user manual — Technical Data
Page 27 · click to enlarge
Page 27

Technical Data

Maximum Fluid Pressure 4000 psi (28 MPa, 276 bar)

Maximum Cylinder Air Pressure 120 psi (0.84 MPa, 8.4 bar)

Air inlets (open and close ports) 1/8 npt(f)

Fluid Inlet 1/4 npt(f)

Fluid Outlet 1/4 npt(f) and 3/4–16 unf(m)

Fluid Viscosity Range 20 cps to 1 million cps

Snuffer Action Fluid Section Isolation chamber with zerk fittings

Divorced Air Cylinder Piston cylinder, EP o-rings

Aluminum Valve Stainless Steel Valve Handle Kit

1.43 lb (0.65 kg) 2.07 lb (0.94 kg) 0.77 lb (0.35 kg)

Aluminum Valve aluminum, 303 stainless steel, 17–4 PH stainless steel, C2 car- bide, hard chrome, ethylene propylene, Parker Polymite, PTFE

Stainless Steel Valve 303 stainless steel, 17–4 PH stainless steel, C2 carbide, hard chrome, ethylene propylene, Parker Polymite, PTFE

Shaft Snuffer Needle Seat Shaft Seal, standard Shaft Seal, optional

Hard chrome over 303 stainless steel Hardened 440–C stainless steel Reversible, solid C2 carbide inserts High density Parker Polymite PTFE

Loctite is a registered trademark of the Loctite Corporation.

Show 5 more labels / short text on this page
Category Data · Weight · Wetted Parts · Severe-duty Components ·
Page 28 of the Graco 965768 user manual — Dimensions
Page 28 · click to enlarge
Page 28

Dimensions

Graco 965768 — Dimensions diagram (page 28)
Fig. 9 · Dimensions

Page 29 of the Graco 965768 user manual — Notes
Page 29 · click to enlarge
Page 29

Notes

Page 30 of the Graco 965768 user manual — Graco Information
Page 30 · click to enlarge
Page 30

Graco Standard Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com

TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers

to identify the distributor closest to you:

1–800–328–0211 Toll Free 612–623–6921 612–378–3505 Fax

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents Original instructions. This manual contains English. MM 308876

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES P.O. BOX 1441 MINNEAPOLIS MN 55440–1441 USA Copyright 1998, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com Revised 12 June 2012

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Valve does not openInsufficient air pressureTurn on or turn up air pressure. p.10
Valve does not openAir not exhausted from behind air cylin- der pistonUse four-way, relieving-type air valve operator. p.10
Valve does not openShaft adjustment too far closedAdjust the shaft stroke as instructed on page 9. p.10
Valve does not close (leaks)Insufficient air pressureTurn on or turn up air pressure. p.10
Valve does not close (leaks)Air not exhausted from behind air cylin- der pistonUse four-way, relieving-type air valve operator. p.10
Valve does not close (leaks)Blockage between needle and seatRemove and clean needle and seat. p.10
Valve does not close (leaks)Bad or missing gasket between seat and housingReplace gasket (38). p.10
Valve does not close (leaks)Needle worn outReplace needle and seat. p.10
Higher than normal back-pressureNosepiece plugging upRemove and clean. p.10

Ask about the Graco 965768

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 965768

Be the first to ask — other owners or our team will answer.

Original document

Graco 965768 manual PDF

30 pages·287 KB·Glue Gun·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…