LD Series Oil and Grease Pump 3A1334F

EN

For dispensing non-corrosive and non-abrasive lubricants, oil, grease, and automatic transmission fluids in stationary or mobile installations. Use with compressed air only. For professional use only. Not for use with windshield washer fluid.

List of models, including Maximum Fluid Pressure:

Graco 3A1334F — EN diagram (page 1)
Fig. 1
  • Oil Pump Models: page 2
  • Grease Pump Models: page 3

Related Translated Manuals

Manual NumberLanguage 3A1339Spanish 3A1345French 3A1350German 3A1360Russian 3A1365Chinese 3A1370Japanese 3A1375Korean
Page 2 of the Graco 3A1334F user manual — Oil Pump Models
Page 2 · click to enlarge
Page 2

Oil Pump Models

All oil models include a 2” npt(m) bung adapter.

PNDescriptionMax air pressureMax Fluid PressureAir inletFluid InletFluid Outlet 3:1 PUMPSpsiMpabarpsiMpabar 24G576Universal1501.0310.37505.1751.71/4"-18 NPT1"-11.5 NPT1/2"-14 NPT 24G577Universal1501.0310.37505.1751.71/4"-19 BSPP1-11 BSPP1/2"-14 BSPP 24G578Universal1501.0310.37505.1751.71/4"-19 BSPT1-11 BSPT1/2”-14 BSPT 24G579*Multilength1501.0310.37505.1751.71/4"-18 NPT1"-11.5 NPT1/2"-14 NPT 24G580*Multilength1501.0310.37505.1751.71/4"-19 BSPP1-11 BSPP1/2"-14 BSPP 24G581*Multilength1501.0310.37505.1751.71/4"-19 BSPT1-11 BSPT1/2”-14 BSPT 24G582*200L (55gal) drum1501.0310.37505.1751.71/4"-18 NPT1"-11.5 NPT1/2"-14 NPT 24G583*200L (55gal) drum1501.0310.37505.1751.71/4"-19 BSPP1-11 BSPP1/2"-14 BSPP 24G584*200L (55gal) drum1501.0310.37505.1751.71/4"-19 BSPT1-11 BSPT1/2”-14 BSPT 24G585*1040 liter (275gal) tote1501.0310.37505.1751.71/4"-18 NPT1"-11.5 NPT1/2"-14 NPT 24G586*1040 liter (275gal) tote1501.0310.37505.1751.71/4"-19 BSPP1-11 BSPP1/2"-14 BSPP 24G587*1040 liter (275gal) tote1501.0310.37505.1751.71/4"-19 BSPT1-11 BSPT1/2”-14 BSPT 5:1 PUMPSpsiMpabarpsiMpabarAir inletFluid InletFluid Outlet 24G588Universal1501.0310.37505.1751.71/4"-18 NPT1"-11.5 NPT1/2"-14 NPT 24G589Universal1501.0310.37505.1751.71/4"-19 BSPP1-11 BSPP1/2"-14 BSPP 24G590Universal1501.0310.37505.1751.71/4"-19 BSPT1-11 BSPT1/2”-14 BSPT 24G591*5:1 Multilength1501.0310.37505.1751.71/4"-18 NPT1"-11.5 NPT1/2"-14 NPT 24G592*5:1 Multilength1501.0310.37505.1751.71/4"-19 BSPP1-11 BSPP1/2"-14 BSPP 24G593*5:1 Multilength1501.0310.37505.1751.71/4"-19 BSPT1-11 BSPT1/2”-14 BSPT 24G594*200L (55gal) drum1501.0310.37505.1751.71/4"-18 NPT1"-11.5 NPT1/2"-14 NPT 24G595*200L (55gal) drum1501.0310.37505.1751.71/4"-19 BSPP1-11 BSPP1/2"-14 BSPP 24G596*200L (55gal) drum1501.0310.37505.1751.71/4"-19 BSPT1-11 BSPT1/2”-14 BSPT 24G597*1040 liter (275gal) tote1501.0310.37505.1751.71/4"-18 NPT1"-11.5 NPT1/2"-14 NPT 24G598*1040 liter (275gal) tote1501.0310.37505.1751.71/4"-19 BSPP1-11 BSPP1/2"-14 BSPP 24G599*1040 liter (275gal) tote1501.0310.37505.1751.71/4"-19 BSPT1-11 BSPT1/2”-14 BSPT

Oil Pump Models

Page 3 of the Graco 3A1334F user manual — Grease Pump Models
Page 3 · click to enlarge
Page 3

Grease Pump Models

PNDescriptionMax air pressureMax Fluid PressureAir inletFluid InletFluid Outlet 50:1 PUMPSpsiMpabarpsiMpabar 24G60016kg (35lb)1501.0310.3750051.75171/4"-18 NptPriming piston1/4"-18 Npt 24G60116kg (35lb)1501.0310.3750051.75171/4"-19 BSPPPriming piston1/4"-19 BSPP 24G60216kg (35lb)1501.0310.3750051.75171/4"-19 BSPTPriming piston1/4"-19 BSPT 24G60355kg (120lb)1501.0310.3750051.75171/4"-18 NptPriming piston1/4"-18 Npt 24G60455kg (120lb)1501.0310.3750051.75171/4"-19 BSPPPriming piston1/4"-19 BSPP 24G60555kg (120lb)1501.0310.3750051.75171/4"-19 BSPTPriming piston1/4"-19 BSPT 24G606180kg (400lb)1501.0310.3750051.75171/4"-18 NptPriming piston1/4"-18 Npt 24G607180kg (400lb)1501.0310.3750051.75171/4"-19 BSPPPriming piston1/4"-19 BSPP 24G608180kg (400lb)1501.0310.3750051.75171/4"-19 BSPTPriming piston1/4"-19 BSPT

Grease Pump Models

Page 4 of the Graco 3A1334F user manual — WARNING
Page 4 · click to enlarge
Page 4

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

SKIN INJECTION HAZARD High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

  • Do not point dispense valve at anyone or at any part of the body.
  • Do not put your hand over the end of the dispense nozzle.
  • Do not stop or deflect leaks with your hand, body, glove, or rag.
  • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.
  • Tighten all fluid connections before operating the equipment.
  • Check hoses and couplings daily. Replace worn or damaged parts immediately.

FIRE AND EXPLOSION HAZARD When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be aware that flammable fumes can ignite or explode. To help prevent fire and explosion:

  • Use equipment only in well ventilated area.
  • Eliminate all ignition sources, such as cigarettes and portable electric lamps.
  • Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.
  • Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
  • Ground all equipment in the work area.
  • Use only grounded hoses.
  • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.
  • Keep a working fire extinguisher in the work area.
Page 5 of the Graco 3A1334F user manual — WARNING
Page 5 · click to enlarge
Page 5

WARNING

EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury.

  • Do not operate the unit when fatigued or under the influence of drugs or alcohol.
  • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.
  • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer.
  • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.
  • Do not alter or modify equipment.
  • Use equipment only for its intended purpose. Call your distributor for information.
  • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
  • Do not kink or over bend hoses or use hoses to pull equipment.
  • Keep children and animals away from work area.
  • Comply with all applicable safety regulations.

PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.

  • Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents.
  • Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for compatibility.

PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This equipment includes but is not limited to:

  • Protective eyewear, and hearing protection.
  • Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.
Page 6 of the Graco 3A1334F user manual — Y
Page 6 · click to enlarge
Page 6

Installation

Grounding

  • Air and fluid hoses: Use only electrically conductive hoses.
  • Air compressor: Follow manufacturer’s recommendations.
  • Dispensing valve: Ground through connection to a properly grounded fluid hose and pump.

To reduce the risk of static sparking, ground the pump and all other components used or located in the dispensing area. Check your local electrical code for detailed instructions for your area and type of equipment.

  • Object being dispensed to: Follow your local code.
  • Solvent pails used when flushing: Follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity.

Ground all equipment:

  • Pump: Use a ground wire and clamp as shown in F IG . 1.
  • To maintain grounding continuity when flushing or relieving pressure, hold a metal part of the dispensing valve firmly to the side of a grounded metal pail, then trigger the dispense valve.

a. Remove the ground screw (Z) and insert through the eye of the ring terminal at end of ground wire (Y).

b. Fasten the ground screw back onto the pump and tighten securely.

Graco 3A1334F — Grounding diagram (page 6)
Fig. 2 · Grounding

Y

Z

Installation · ti16123

Page 7 of the Graco 3A1334F user manual — Stationary Mountings
Page 7 · click to enlarge
Page 7

Typical Installation

The typical installation shown in FIG. 2 is only an installation guide. It is not an actual system design. Contact your Graco Distributor for assistance in designing a system to suit your needs.

Stationary Mountings

Graco 3A1334F — Stationary Mountings diagram (page 7)
Fig. 3 · Stationary Mountings

Recommended air line configuration to reduce moisture in pump

Key (FIG. 2)

  • A Fluid outlet line (flexible connection required) B Pump C Ground wire D Pump runaway valve E Air lubricator F Bleed-type master air valve (required)
  • NPT - Part No. 110223
  • BSP - Part No. 125272 G Air regulator (self-relieving regulator required)
  • NPT - Part No. 24H420
  • BSP - Part No. 24H419 H Air filter J Main air line K Bung adapter - Part No. 24F918 L Fluid inlet line (flexible connection required) M Air inlet line (flexible connection required) N Wall mount bracket - Part No. 24F910

Installation

Page 8 of the Graco 3A1334F user manual — A
Page 8 · click to enlarge
Page 8

Installation Guidelines

Reference letters found in the following instructions, refer to Typical Installation diagram provided on page 7.

1. Install bung adapter (K) into bung mount/bracket/or drum cover.
2. Install pump (B) into bung adapter (K).
  • A ball valve must be installed upstream of the regulator (G).
  • The fluid outlet line (A), fluid inlet line (L) and air inlet line (M) must be flexible (such as a hose).
Graco 3A1334F — Installation Guidelines diagram (page 8)
Fig. 4 · Installation Guidelines

B

A

K

The maximum working pressure of each pump in your system may not be the same. To reduce the risk of over-pressurizing any part of your system, which may result in component rupture, fire or explosion and cause serious bodily injury, be sure you know the maximum working pressure rating of each pump and its connected components.

Installing Outlet Hose (FIG. 3)

1. Connect the swivel adapter (aa) to the pump fluid outlet. Tighten securely and torque as recommended below:
  • Never exceed the maximum working pressure of the lowest rated component connected to a particular pump.
  • For NPT models: 1 to 1-1/2 turns past hand tight.
  • For BSPT models: 1-1/2 to 2 turns past hand tight.
  • Be sure you know the maximum working pressure of each component.
  • Do not exceed the maximum pump cycle rate.
2. Connect the fluid hose (A) to the swivel adapter (aa).
  • Regulate air pressure to prevent over pressurization at fluid section of the pump.
3. Connect a suitable dispensing valve or extra hose to the 6-ft hose.
  • Regulate air pressure to the pump so that no fluid line component or accessory is over pressurized.

Plan the layout for easy operator access to the pump air controls, sufficient room to change drums and a secure platform.

Show 4 more labels / short text on this page
Installation · Pump Mounting · aa · Stationary Mounting Layout
Page 9 of the Graco 3A1334F user manual — Follow Plate - Grease Models Only
Page 9 · click to enlarge
Page 9

Air Line and Accessories

NOTICE

Do not hang the air accessories directly on the air inlet. Mount them on brackets. Always use a flexible hose between all connections. The air inlet is not strong enough to support accessories and may cause one or more to break.

  • Use thread sealant on all male threads except swivel connections.
  • Install a pump runaway valve (D) to shut off the air to the pump if the pump accelerates beyond the pre-adjusted setting. A pump that runs too fast can be seriously damaged.
  • Install the air regulator (G) to control pump speed and pressure.

For NPT models order Graco Part No. 24H420 or for BSP models order Graco Part No. 24H419.

  • Install a bleed-type master air valve (F) upstream from the pump air regulator (G) but within easy reach of the pump.

For NPT models order Graco Part No. 110223 or for BSP models order Graco Part No. 125272.

  • On the main air supply line from the compressor, install an air line filter (H) to remove harmful dirt and contaminants from the compressor air supply.

Follow Plate - Grease Models Only

For grease models only a follow plate is required for pumping fluid from the drum. See page 12 for follow plate installation instructions.

Installation

Page 10 of the Graco 3A1334F user manual — NOTE:
Page 10 · click to enlarge
Page 10

Operation

Graco 3A1334F — Operation diagram (page 10)
Fig. 5 · Operation
Graco 3A1334F — Operation diagram (page 10)
Fig. 6 · Operation

Thermal Induced Pressure Relief (Oil pumps only)

THERMAL EXPANSION HAZARD Fluids subjected to heat in confined spaces, including hoses, can create a rise in pressure due to the thermal expansion. Over-pressurization can result in equipment rupture and serious injury.

Graco 3A1334F — Thermal Induced Pressure Relief (Oil pumps only) diagram (page 10)
Fig. 7 · Thermal Induced Pressure Relief (Oil pumps only)

Oil pumps have a built-in, thermal induced, pressure relief as shown in FIG. 4. To ensure system pressure will automatically bleed excess thermal induced system pressure through the pump and back to the oil reservoir:

FIG. 4 a = Pump cylinder relief passage

  • Always use a relieving air pressure regulator to allow the pump/motor to run backwards. The regulator bleeds excess air pressure.

b = Inlet check relief passage

Thermal Relief Theory of Operation

  • There should not be any obstructions between air inlet of pump and regulator.

The pump operation is similar to most double acting reciprocating pumps. The pump only comes to a com- plete stop on the up stroke. The pump will stroke through on the down stroke due to the inlet check relief passage.

  • There should not be any obstructions between the downstream plumbing and pump outlet such as closed ball valves or check valves.

Excess pressure due to downstream thermal expansion causes the air motor/pump to run backwards (down- ward). Fluid pressure is relieved through the inlet check relief passage as the pump piston moves downward. Air pressure is simultaneously relieved through the air inlet passage. The pump piston moves downward exposing the pump cylinder relief passage at the bottom of the stroke. Additional excess pressure is then relieved through both the inlet check relief passage and the pump cylinder relief passage.

  • There should not be any obstructions between the pump inlet and fluid container such as closed ball valves or check valves.
  • Only use Graco designed suction tubes for in-drum or in-tank applications.
  • Only use Graco designed suction tubes with a built-in relief device for wall mount applications.

Pressure is relieved at the pump through the pump inlet relief passage. The pump will not change over on the bottom of the stroke as a result of relieving excess pres- sure due to the positioning of the pump cylinder groove with respect to the air motor pilot valve.

  • Always use an inlet screen to prevent debris from plugging relief passages from entering the pump.

- Do not operate the pump with out an inlet screen.

NOTE:

  • Periodically inspect the inlet screen for plugging. Graco recommends inspecting the inlet screen every time the container is changed out.
  • The air supply does not have to be turned off to enable thermal relief activation.
  • The Thermal Induced Pressure Relief design feature of the pump will cause the pump to dive on the downstroke when a dispensing valve is closed.

Operation · a · b

Page 11 of the Graco 3A1334F user manual — Priming the pump
Page 11 · click to enlarge
Page 11

Install only one pump per delivery system. Do not use the pumps in a parallel pump installation.

Start-up

Loss of pump prime can occur if all the following events occur in sequence:

Determining Output Pressure Using the Air Regulator

1. A thermal relief event occurs.

To determine the fluid output pressure using the air reg- ulator reading, multiply the ratio of the pump by the air pressure shown on the regulator.

2. The air supply valve is closed.
3. A dispense valve located at an elevation higher than the tank level, is open.

For example a 3:1 ratio oil pump:

To prevent loss of prime, ensure the air supply valve is turned on before attempting to dispense fluid.

3:1 ratio x 100 psi air = 300 psi fluid outlet

A 3:1 pump is capable of 5:1 on the downstroke and will develop 5:1 pressures under normal operation.

Pressure Relief Procedure

A grease pump has a ratio of 50:1. However it is capable of reaching a stall pressure equal to 60 times the air input pressure. To calculate the fluid output pressure using the air regulator reading, multiply the regulator gauge by 60.

The equipment stays pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, fluid from the valve, or splash- ing fluid, follow this procedure whenever you:

For example:

140 psi air x 60 = 8400 psi fluid output 0.97 MPa air x 60 = 58.2 MPa 99.7 bar x 60 = 582 bar

  • are instructed to relieve pressure
  • stop dispensing
  • check, clean, or service any system equipment
  • install or clean dispensing devices.

Regulate air to the pump so that no air line or fluid line component or accessory is over pressurized.

Priming the pump

1. Close the pump’s bleed-type master air valve.
1. Close the air regulators and bleed-type master air valves to all but one pump.
2. Close the pump air regulator and disconnect the air supply hose.
2. Open the master air valve from the compressor.
3. Open the dispensing valve and dispense fluid into a waste bucket/container until pressure is fully relieved.
3. For the pump that is connected, trigger the dispensing valve into a grounded metal waste container making firm, metal-to-metal contact between the container and the valve.

If you suspect that the dispensing valve is clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the dispensing valve coupler or hose end coupling to relieve pressure gradually, then loosen completely.

4. Slowly open the bleed-type master air valve and open the pump air regulator just until the pump is running. When the pump is primed and all air has been pushed out of the lines, release the trigger.
5. If you have more than one pump, repeat this process for each pump in your system.

Operation

Page 12 of the Graco 3A1334F user manual — NOTICE
Page 12 · click to enlarge
Page 12

Step 6 is for Oil Pumps Only:

Changing Grease Drum and Installing Follow Plate (grease models only)

6. The thermal relief feature of this oil pump can increase the amount of time needed to fully prime the pump when compared to pumps without a thermal relief feature. To minimize this effect, prime the pump before connecting it to an already primed distribution system.
1. Relieve pressure , page 10.

NOTICE

2. Remove drum cover by loosening thumb screws (a) (F IG . 5).

Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed, possibly damaging itself. If your pump acceler- ates quickly, or is running too fast, stop it immediately and check the fluid supply. If the supply container is empty and air has been pumped into the lines, prime the pump and lines with fluid, or flush it and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid system.

Graco 3A1334F — NOTICE diagram (page 12)
Fig. 8
7. Read and follow the instructions supplied with each component in your system.
3. Remove pump and cover from drum and place on a clean paper, cardboard, or clean shop rags. DO NOT PLACE ON SHOP FLOOR.
8. When shutting off the system and before checking or servicing, relieve pressure following pressure relief procedure, page 10.
4. If this is an existing installation, reach into drum and pull on follow plate ring (b) to remove follow plate (F IG . 6). Place follow plate on a clean paper, cardboard or clean shop rags. DO NOT PLACE ON SHOP FLOOR.

Remove drum and install new one.

Graco 3A1334F — NOTICE diagram (page 12)
Fig. 9

Operation · a · b

Page 13 of the Graco 3A1334F user manual — Pressure Relief Procedure
Page 13 · click to enlarge
Page 13
5. Examine follow plate to make sure rubber grommet (c) is in place in center of the plate (F IG . 7).
7. Insert pump drop tube through center of rubber grommet in follow plate (F IG . 9).
Graco 3A1334F — Pressure Relief Procedure diagram (page 13)
Fig. 10 · Pressure Relief Procedure
Graco 3A1334F — Pressure Relief Procedure diagram (page 13)
Fig. 11 · Pressure Relief Procedure
6. Set follow plate on top of fresh grease (F IG . 8). Remove air by pushing on the follow plate until the grease level is flush with the opening in the middle of the follow plate (d).
Graco 3A1334F — Pressure Relief Procedure diagram (page 13)
Fig. 12 · Pressure Relief Procedure
8. Tighten thumb screws (a) to secure cover to drum.
Graco 3A1334F — Pressure Relief Procedure diagram (page 13)
Fig. 13 · Pressure Relief Procedure
9. For the pump that is connected, trigger the dispensing valve into a grounded metal waste container making firm, metal-to-metal contact between the container and the valve.
10. Slowly open the bleed-type master air valve and open the pump air regulator just until the pump is running. When the pump is primed and all air has been pushed out of the lines, release the trigger.
Show 4 more labels / short text on this page
Operation · Se · d · a
Page 14 of the Graco 3A1334F user manual — Repair
Page 14 · click to enlarge
Page 14

Repair

Replacing Pilot Valves

Reference letters shown in the following instructions refer to Typical Installation diagram, page 7. Part num- bers refer to the Parts pages beginning on page 15.

1. Stop pump at the middle of its stroke.
2. Relieve pressure, page 11.
3. Disconnect the air line (M).
4. Use a 10 mm socket wrench to remove the old pilot valve (20).
5. Lubricate o-rings and install the new pilot valve (20). Torque to 95-105 in-lb (11-12 N.m).

Repair

Page 15 of the Graco 3A1334F user manual — 24 15M213 MUFFLER, 3/8 1
Page 15 · click to enlarge
Page 15

Parts

3:1 Oil Pump Models: 24G576 - 24G587: 5:1 Oil Pump Models: 24G588 - 24G599

Ref Part No Description Qty

Ref Part No Description Qty

2 116343 SCREW, ground 1

40 ▲ 16G243◆LABEL, safety, warning, multiple 1

3 SCREW 3

43 ✿ SCREW, M6 x 25 mm 8 50 24F918 ADAPTER, bung, LD pump 1

4 SCREW M6 x 22 mm 5

5 ✠ O-RING, air piston 1

51 16G121 ★ STRAINER 1

6 ✠ O-RING 1

16F878 TUBE, PVC, LD pump (models 24G579, 24G591) 1

7 ✠ O-RING 1

16F948 TUBE, PVC, LD pump (models 24G580, 24G592) 1

8 ✠ O-RING, 1

9 ✠ SEAL, u-cup 1

16F949 TUBE, PVC, LD pump (models 24G581, 24G593) 1

10 PIN, spring 1

16F886 TUBE, metal, LD pump (models 24G582, 24G594) 1

11 ★ BALL, steel 1

12 BALL, steel 1

16F950 TUBE, metal, LD pump (models 24G583, 24G595) 1

13 ✓ O-RING, (models 24G576 - 24G578) 1

16F951 TUBE, metal, LD pump (models 24G584, 24G596) 1

✓ O-RING (models 24G588 - 24G590) 1 14 ✓ O-RING 1

16F885 TUBE, metal, LD pump (models 24G585, 24G597) 1

15 ✓★ O-RING 1

16 SCREW 1

16F962 TUBE, metal, LD pump (models 243G586, 24G598) 1

17 ✠ O-RING 3

16F963 TUBE, metal, LD pump (models 24G587, 24G599) 1

18 BOLT M8 X 25 1

19 WASHER, M8 (not shown) 1

55 ✠ O-Ring (not shown) 1

20 ◆ ✖ VALVE, pilot 2

21 PISTON, air, plastic 1

▲Replacement Danger and Warning labels, tags, and

22 BEARING, delrin 1

cards are available at no cost.

23 15M182 ❖ †✿ ◆SEAL, air valve, manifold (not shown) 1

‡ Packaged separately with universal pump.

24 15M213 MUFFLER, 3/8 1

✠Included in kit 24H853 ✓Included in kits 24K293 - 3:1; 24H855 - 5:1 ★Included in kits 24H611 (npt), 24J430 (bspp) 24J431

112933 MUFFLER, quiet (optional) 1

25 ✠ GASKET, cover, small 2

26 COVER, bottom, machining 1

(bspt) ❖Included in kit 24H798

27 CYLINDER air, machined 1

28 ★ HOUSING, intake valve, machined 1

† Included in kit 24H851 ✿Included in kit 24H848 (npt), 24H849 (bspp), 24H850

29 FLANGE, oil, machined 1 30 ROD, displacement 1

(bspt) ◆Included in kit 24J757 (npt), 24J758 (bspp), 24J759

31 GUIDE, air 1

(bspt) ✖Included in kit 24H749

32 CYLINDER, fluid 1

33 PISTON, pump, 3:1, machining 1 34 HOLDER, ball 1

35 ★ SPRING, compression 1

36 SPRING, compression 1

37 HOUSING, manifold, machined 1

38 ✿ VALVE, air, small 1

39 ▲ 16F541 LABEL, identification, lD 3:1 1

Show 4 more labels / short text on this page
Parts · 52‡ · 53‡ · 54‡
Page 16 of the Graco 3A1334F user manual — Throat and Piston Seal Replacement Kit - 24H853 (F IG . 12)
Page 16 · click to enlarge
Page 16

Related Oil Pump Kits

Throat and Piston Seal Replacement Kit - 24H853 (F IG . 12)

Kit No. Description Qty

24H611 KIT, repair, intake valve, npt, includes 11, 15, 28, 35, 51 1

24J430 KIT, repair, intake valve, bspp, includes 11, 15, 28, 35, 51 1

24J431 KIT, repair, intake valve, bspt, includes 11, 15, 28, 35, 51 1

Ref. Description Qty. 5 O-RING, air piston 1 6 O-RING 1 7 O-RING 1 8 O-RING, wiper 1 9 SEAL, u-cup 1 17 O-RING 3 25 GASKET, cover, small 2 55 O-RING (not shown) 1

O-Ring Replacement Kit - 24K293 for 3:1 pumps; 24H855 for 5:1 pumps (FIG. 11)

Ref. Description Qty. 13 O-RING 1 14 O-RING 1 15 O-RING 1

Graco 3A1334F — Throat and Piston Seal Replacement Kit - 24H853 (F IG . 12) diagram (page 16)
Fig. 14 · Throat and Piston Seal Replacement Kit - 24H853 (F I…
Graco 3A1334F — Throat and Piston Seal Replacement Kit - 24H853 (F IG . 12) diagram (page 16)
Fig. 15 · Throat and Piston Seal Replacement Kit - 24H853 (F I…

Parts

Page 17 of the Graco 3A1334F user manual — Related Oil Pump Kits
Page 17 · click to enlarge
Page 17
Graco 3A1334F — Related Oil Pump Kits diagram (page 17)
Fig. 16 · Related Oil Pump Kits

52, 53 or 54, Page 15

Torque to 95-105 in lbs (10.7 - 11.9 N•m) 1

Torque to 20 - 25 ft lbs (27- 34 N•m) 2

Torque to 60 - 70 in lbs (6.8 - 7.9 N•m) 3

Torque to 25 - 35 in lbs (2.8 - 3.9 N•m) 4

Torque to 110 - 120 in lbs (12.4 - 13.6 N•m) 5

Torque to 80 - 90 in lbs (9.0 - 10.2 N•m) 6

Parts

Page 18 of the Graco 3A1334F user manual — 30 +@ GASKET 2
Page 18 · click to enlarge
Page 18

50:1 Grease Pump Models: 24G600 - 24G608

Ref Part No. Description Qty

Ref Part No. Description Qty

2 116343 SCREW, ground 1

34 ROD, priming 1

3 SCREW 3

35 PISTON, shovel, 50:1 1

4 SCREW, M6 X 22 mm 5

36 CYLINDER, spacer 1

37 + NUT, retainer 1

5 + O-RING, air piston 1

6 + O-RING (not shown) 1

38 WASHER, 30 OD 1

7 + O-RING 10

39 HOUSING, manifold, machined 1

8 +@ PIN, straight, slotted, 2.5x16 3

40 ✿◆ VALVE, air, small 1

9 SCREW 1

41 ▲1GH013 LABEL, identification, LD 50:1 1

10 @ O-RING 1

42 ▲16G243 LABEL, safety, warning, multiple 1

11 + SEAL, u-cup 1

43 ✿ SCREW, M6 x 25 mm 8

12 + O-RING 3

▲Replacement Danger and Warning labels, tags, and

13 WASHER,M8 1

cards are available at no cost.

14 COVER, bottom, machining 1

15 PISTON, air, plastic 1

16 15M182 ❖ † ✿◆SEAL, air valve, manifold 1

+ Included in kit 24H854 @ Included in kits 24H856

17 15M213 MUFFLER, 3/8 1

★Included in kits 24H611 (npt), 24J430 (bspp) 24J431

(bspt) ❖Included in kit 24H798

112933 MUFFLER, quiet (optional) 1

18 + GASKET, cover, small 2

† Included in kit 24H851 ✿Included in kit 24H848 (npt), 24H849 (bspp), 24H850

19 NUT, hex 2

(bspt) ◆Included in kit 24J757 (npt), 24J758 (bspp), 24J759

20 ◆ ✖ VALVE, pilot 2

21 CYLINDER, air, machined 1

(bspt) ✖Included in kit 24H749

22 FLANGE, bottom cover, grease, 1

23 ROD, piston, 50:1 1

24 @ SEAL, piston 1

25 ROD, displacement, 50:1 1

26 CYLINDER, HP 50:1 1

27 24J380 KIT, cylinder, shovel 1

28 @ SEAL, intake 1

29 RETAINER, seal, al 1

30 +@ GASKET 2

31 BEARING, throat 1

32 ROD, connection 1

33 GUIDE, air 1

Parts

Page 19 of the Graco 3A1334F user manual — Throat and Piston Seal Replacement Kit - 24H854 (F IG . 13)
Page 19 · click to enlarge
Page 19

Related Grease Pump Kits

Throat and Piston Seal Replacement Kit - 24H854 (F IG . 13)

O-Ring and Seal Replacement Kit - 24H856 (F IG . 14)

Instructions related to this kit are included in instruction manual 3A1495 (included with the kit).

Instructions related to this kit are included in instruction manual 3A1495 (included with the kit).

Ref. Description Qty. 5 O-RING, air piston 1 6 O-RING 1 7 O-RING 1 8 PIN, slotted, straight 3 11 SEAL, u-cup 1 12 O-RING 3 18 GASKET, cover, small 2 30 GASKET 1 37 NUT, retainer 1

Ref. Description Qty. 8 PIN, slotted, straight 3 10 O-RING 1 24 SEAL, piston 1 28 SEAL, intake 1 30 GASKET 2

Graco 3A1334F — Throat and Piston Seal Replacement Kit - 24H854 (F IG . 13) diagram (page 19)
Fig. 17 · Throat and Piston Seal Replacement Kit - 24H854 (F I…
Graco 3A1334F — Throat and Piston Seal Replacement Kit - 24H854 (F IG . 13) diagram (page 19)
Fig. 18 · Throat and Piston Seal Replacement Kit - 24H854 (F I…

Parts

Page 20 of the Graco 3A1334F user manual — Related Grease Pump Kits
Page 20 · click to enlarge
Page 20
Graco 3A1334F — Related Grease Pump Kits diagram (page 20)
Fig. 19 · Related Grease Pump Kits

Torque to 95-105 in lbs (10.7 - 11.9 N•m) 1

Torque to 60 - 70 in lbs (6.8 - 7.9 N•m) 3

Torque to 70 - 80 in lbs (7.9 - 9.0 N•m) 7

Torque to 45 - 55 ft lbs (61 - 75 N•m) 8

Torque to 30 - 40 in lbs (3.4 - 4.5 N•m) 9

Torque to 30 - 35 in lbs (3.4 - 4.0 N•m) 10

Parts

Page 21 of the Graco 3A1334F user manual — Air Valve Seal Kit - 24H851
Page 21 · click to enlarge
Page 21

Oil or Grease Pump Air Valve Repair and Replacement Kits

Air Valve Seal Kit - 24H851

Graco 3A1334F — Air Valve Seal Kit - 24H851 diagram (page 21)
Fig. 20 · Air Valve Seal Kit - 24H851

Instructions related to the following kits are included in instruction manual 3A1496 (included with the kit).

Air Valve Repair Kit - 24H798, Air Valve Seal Kit - 24H851 and Air Valve End Cap - 24H852.

381 1 Lips face down Lips face up 2

Parts

Page 22 of the Graco 3A1334F user manual — I F IG . 18
Page 22 · click to enlarge
Page 22

Air Valve Replacement Kit - 24H848 (npt), 24H849 (bspp), 24H850 (bspt) (FIG. 18) Pilot Valve Replacement Kit - 24H749

This kit only includes the pilot valves (20). If you also are repairing/replacing the air valve (38/40) and air valve seal (23/16) order the Air Motor Service Kit - 24J757 (npt), 24J758 (bspp) or 24J759 (bspt).

Graco 3A1334F — Oil or Grease Pump Air Valve Repair and Replacement Kits diagram (page 22)
Fig. 21 · Oil or Grease Pump Air Valve Repair and Replacement…

Ref. Description Qty. 20 VALVE, pilot 2

Air Motor Service Kit - 24J757 (npt), 24J758 (bspp), 24J759 (bspt) (FIG. 19)

I F IG . 18

Graco 3A1334F — I F IG . 18 diagram (page 22)
Fig. 22

Ref. Description Qty. Oil Grease

23 16 SEAL, air valve 1

38 40 VALVE, air, small 1

43 43 SCREW, M6 x 25 4

Ref. Description Qty. Oil Grease

20 20 VALVE, pilot 2

23 16 SEAL, air valve 1

40 40 VALVE, air, small 1

Show 5 more labels / short text on this page
Parts · 38/40 · 23/16 · 38/40 · 23/16
Page 23 of the Graco 3A1334F user manual — Oil Models
Page 23 · click to enlarge
Page 23

Troubleshooting

Oil Models

Crack a fitting at the outlet of the pump to allow a slow leak to purge any air in the pump. Repeat start up procedure, page 11.

Pump is not fully primed

Oil leakage Check connection and tighten.

The piston valve is not seating prop- erly or the piston o-ring is damaged Check and replace parts as needed.

Pump runs but no fluid output

Exhausted fluid supply Refill and reprime.

The pump inlet filter is blocked Clear the filter

The suction tube (hose) has an air leak

Check the connection and tighten as needed.

Service pilot valve.

Lower air pressure to prevent reoc- currence.

Replace air valve.

Damaged main air valve

Lower air pressure to prevent reoc- cur an ce.

Pump fails to operate or stops

Inadequate air supply pressure or restricted air lines. Increase air supply; clear.

Closed or clogged dispensing valve Open valve if closed. Clear clog if necessary.

Clogged fluid lines, hose valves, etc. Clear clogs.

Damaged air motor Service air motor.

Exhausted fluid supply Refill and reprime.

Replace valve gasket.

Erratic or accelerated operation

Lower air pressure to prevent reoc- currence.

Show 4 more labels / short text on this page
Troubleshooting · Problem Cause Solution · Damaged pilot valve · Damaged valve gasket
Page 24 of the Graco 3A1334F user manual — Troubleshooting
Page 24 · click to enlarge
Page 24

Replace gasket.

Intermittent air leakage coming from behind the air manifold. Pump con- tinues to function normally.

Lower air pressure to prevent reoc- currence.

Clear obstruction.

Thermal relief inlet check relief pas- sage in inlet housing is plugged

Replace inlet filter.

Worn or damaged piston o-ring or valve cup. Service air motor / valve

Replace valve gasket.

Lower air pressure to prevent reoc- currence.

Held open or worn intake valve Clear; service.

Held open or worn pump piston packings Clear; service.

The muffler is partially blocked Clear muffler.

The inlet filter is partially blocked Clear the filter.

Pump operates but output is low

Inadequate air supply pressure or restricted air lines

Increase air supply; clear restric- tions.

Partially closed or clogged pilot valves

Open valves. Clear clog as neces- sary.

Partially clogged fluid line, hose, valves, etc. Clear clog as necessary.

Oil leakage through air exhausts Throat seal is damaged Replace throat seal (u-cup).

Show 5 more labels / short text on this page
Troubleshooting · Problem Cause Solution · Gasket is leaking · Continuous air exhaust · Damaged valve gasket
Page 25 of the Graco 3A1334F user manual — Grease Models
Page 25 · click to enlarge
Page 25

Grease Models

Pump fails to operate Inadequate air supply pressure or restricted air lines

Increase air supply and/or clear restriction.

Closed or clogged pump valves Open and/or clean.

Clogged fluid line, hose, valve, or other accessory

Relieve pressure. Clear obstruction.

Damaged air motor Assess damage, and service air motor.

Exhausted fluid supply Refill and reprime or flush.

Continuous air exhaust Worn or damaged piston o-ring or valve cup

Assess wear or damage, and service air motor.

Erratic pump operation Exhausted fluid supply Refill and reprime or flush.

Worn pump seals Replace.

Damaged shovel tube Replace.

Damaged check seat Replace pump piston or shovel rod (or other damaged part).

Errataic or accelerated pump speed Exhausted fluid supply Refill and reprime of flush.

Fluid too heavy for pump priming Use inductor or follow plate.

Replace valve gasket.

Lower air pressure to prevent reoc- currence.

Worn piston seal Replace.

Damaged upper check seat Replace pump piston.

Worn fluid intake seal Replace.

Damaged lower check seat Replace shovel rod.

Inadequate air supply pressure or restricted air lines

Increase air supply and/or clear restriction.

Pump operates but output is low

Partially closed or clogged pump valves

Open and/or clean.

Air pockets in the grease inlet Eliminate the air pockets.

Partially clogged fluid line, hose, valve, or other accessory

Relieve pressure. Clear obstruction.

Worn seals Replace.

Grease leaking from muffler Worn throat seal Replace.

Troubleshooting · Damaged valve gasket

Page 26 of the Graco 3A1334F user manual — Technical Data
Page 26 · click to enlarge
Page 26

Technical Data

3:1 or 5:1 Oil Models

Maximum fluid working pressure 750 psi (51.7 bar, 5.17 MPa)

Fluid pressure ratio 3:1 or 5:1

Suction lift (feet of oil) 10

Air operation range 20 to 150 psi (1.37 to 10.3 bar; 0.137 to 1.03 MPa)

Recommended air pressure for optimum pump life

Air consumption (at 100 psi) See Performance Curves, page 29

Cycles per gallon/(liter) 3:1 - 29 cycles per gallon (7 cycles per liter); 5:1 - 37 cycles per gallon) (10 cycles per liter)

Maximum recommended pump speed 3:1 - 120 cycles per minute; 5:1 - 180 cycles per minutes

Recommended speed for optimum pump life

75 cycles per minute and lower 3:1 - 2.6 gallons per minute (9.8 liters per minute); 5:1 - 2 gallons per minute (7.6 liters per minute)

Wetted parts zinc plated carbon, steel, aluminum, nitrile, polyurethane, nickel plated aluminum

Sound pressure level†* 72.9 dB(a)

Sound power level‡* 82.0 dB(a)

Performance curve See charts page 28

Approximate weight 3:1 - 7 pounds (3.2 kg); 5:1 - 7.7 pounds (3.5 kg)

Dimensions See page 30

† Calculated at a distance of 1 meter from measurements taken per ISO 9614-2 @ 100 psi air pressure (6.89 bar, 0.68 MPa) and 20 cycles per minutes.

‡ Measured per ISO 9614-2 at 100 psi air pressure (6.89 bar, 0.68 MPa) and 20 cycles per minute.

* Muffler 112933 can be ordered separately for reduced sound levels.

Technical Data

Page 27 of the Graco 3A1334F user manual — Dimensions
Page 27 · click to enlarge
Page 27

Dimensions

Graco 3A1334F — Dimensions diagram (page 27)
Fig. 23 · Dimensions
Graco 3A1334F — Dimensions diagram (page 27)
Fig. 24 · Dimensions

*Multi down tube is angle cut to the desired length as required

3/8” (10 mm) minimum

Graco 3A1334F — Dimensions diagram (page 27)
Fig. 25 · Dimensions
Graco 3A1334F — Dimensions diagram (page 27)
Fig. 26 · Dimensions

a = 1/4 inch air inlet b = 1 inch fluid inlet c = 2 inch npt bung adapter d = ground screw

e = 1/2 inch fluid outlet - opposite of d

Show 6 more labels / short text on this page
Technical Data · Universal Pump Multi/Drum/Tote · a · d d · b · b
Page 28 of the Graco 3A1334F user manual —
Page 28 · click to enlarge
Page 28

Performance Curve

3:1 Oil Models

3:1 Performance Curve Tested with ISO 46 Hyd Oil

58 116 174 232

!"#

40 (1.1)

400 (27.6)

$ % &"#

30 (.8)

300 (20.7)

)

% ' &"#

20 (.6)

200 (13.8)

10 (.3)

100 (6.9)

0 1 (3.8)

2 (7.6)

3 (11.4)

4 (15.1)

5 (18.9)

6 (22.7)

7 (26.5)

8 (30.3)

9 (34.1)

5:1 Oil Models

5:1 Performance Curve Tested with ISO 46 Hyd Oil

!"#

$ % &"#

600 (41.4)

40 (1.1)

)

500 (34.5)

% ' &"#

400 (27.6)

30 (.8)

300 (20.7)

20 (.6)

200 (13.8)

10 (.3)

100 (6.9)

0 1 (3.84)

2 (7.6)

3 (11.4)

4 (15.1)

5 (18.9)

6 (26.5)

7 (26.5)

Show 17 more labels / short text on this page
Technical Data · · () * · · · "# · + ,#+# · · · () * · 74 148 222 · "# · · · + ,#+# · ·
Page 29 of the Graco 3A1334F user manual —
Page 29 · click to enlarge
Page 29

50:1 Grease Models

Maximum working pressure 7500 psi (517 bar, 51.7 MPa)

Fluid pressure ratio 50:1

Air operation range 20 to 150 psi (1.37 to 10.3 bar; 0.137 to 1.03 MPa)

Air consumption (at 100 psi) See Performance Curve, page 30

Pump cycles per pound (cycles per kg) 47 cycle per pound (103 cycle per kg)

Maximum recommended pump speed 120 cycles per minute

Recommended speed for optimum pump life 60 cycles per minute or lower flow rate; 1.3 pounds per minute

(0.6 kg per minute)

Wetted parts steel, brass, nitrile rubber, polyurethane, UHMWPE, acetal

Sound pressure level†* 72.9 dB(a)

Sound power level‡* 82.0 dB(a)

Performance curve See chart page 30

Approximate weight 35 pound drum - 11.2 pounds (5.1 kg); 120 pound drum - 15.0 pounds (6.8 kg); 400 pound drum - 170.0 pounds (7.7 kg)

Dimensions See illustration below

† Calculated at a distance of 1 meter from measurements taken per ISO 9614-2 @ 100 psi air pressure (6.89 bar, 0.68 MPa) and 20 cycles per minutes.

‡ Measured per ISO 9614-2 at 100 psi air pressure (6.89 bar, 0.68 MPa) and 20 cycles per minute.

* Muffler 112933 can be ordered separately for reduced sound levels.

Performance Curve

50:1 Performance Curve Tested with ISO 46 Hyd Oil

!"#

8000 (551.6)

$ % &"#

7000 (482.6)

50 (1.4)

% ' &"#

6000 (413.7)

40 (1.1)

)

5000 (344.7)

4000 (275.8)

30 (.8)

3000 (206.8)

20 (.6)

2000 (137.9)

10 (.3)

1000 (68.9)

0.00 0.50 (.23)

1.00 (.45)

1.50 (.68)

2.00 (.91)

2.50 (1.13)

3.00 (1.36)

3.50 (1.59)

4.00 (1.81)

"

Show 9 more labels / short text on this page
Technical Data · Grease Models · () * · 47 94 141 · · · "# · + ,#+# · -
Page 30 of the Graco 3A1334F user manual — Dimensions
Page 30 · click to enlarge
Page 30

Dimensions

a = 1/4 inch air inlet b = 1/4 inch fluid outlet c = 2 inch npt mounting configuration d = ground screw

Graco 3A1334F — Dimensions diagram (page 30)
Fig. 27 · Dimensions

14.5 in. 370 mm 28.1 in. 715 mm 36.0 in. 915 mm

Technical Data

Page 31 of the Graco 3A1334F user manual — Notes
Page 31 · click to enlarge
Page 31

Notes

Page 32 of the Graco 3A1334F user manual — GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Page 32 · click to enlarge
Page 32

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Original instructions. This manual contains English. MM 3A1334

For patent information, see www.graco.com/patents

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441

Copyright 2011, Graco Inc. is registered to ISO 9001

www.graco.com 4/2011, revised March 2012

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Pump runs but no fluid outputPump is not fully primedCrack a fitting at the outlet of the pump to allow a slow leak to purge any air in the pump. Repeat start up procedure, page 11. p.23
Pump runs but no fluid outputOil leakageCheck connection and tighten. p.23
Pump runs but no fluid outputThe piston valve is not seating prop- erly or the piston o-ring is damagedCheck and replace parts as needed. p.23
Pump runs but no fluid outputExhausted fluid supplyRefill and reprime. p.23
Pump runs but no fluid outputThe pump inlet filter is blockedClear the filter p.23
Pump runs but no fluid outputThe suction tube (hose) has an air leakCheck the connection and tighten as needed. p.23
Pump fails to operate or stopsDamaged pilot valveService pilot valve. p.23
Pump fails to operate or stopsLower air pressure to prevent reoc- currence. p.23
Pump fails to operate or stopsDamaged main air valveReplace air valve. p.23
Pump fails to operate or stopsLower air pressure to prevent reoc- cur an ce. p.23
Pump fails to operate or stopsInadequate air supply pressure or restricted air lines.Increase air supply; clear. p.23
Pump fails to operate or stopsClosed or clogged dispensing valveOpen valve if closed. Clear clog if necessary. p.23
Pump fails to operate or stopsClogged fluid lines, hose valves, etc.Clear clogs. p.23
Pump fails to operate or stopsDamaged air motorService air motor. p.23
Erratic or accelerated operationExhausted fluid supplyRefill and reprime. p.23
Erratic or accelerated operationDamaged valve gasketReplace valve gasket. p.23
Erratic or accelerated operationLower air pressure to prevent reoc- currence. p.23
Intermittent air leakage coming from behind the air manifold. Pump con- tinues to function normally.Gasket is leakingReplace gasket. p.24
Intermittent air leakage coming from behind the air manifold. Pump con- tinues to function normally.Lower air pressure to prevent reoc- currence. p.24
Intermittent air leakage coming from behind the air manifold. Pump con- tinues to function normally.Thermal relief inlet check relief pas- sage in inlet housing is pluggedClear obstruction. p.24
Intermittent air leakage coming from behind the air manifold. Pump con- tinues to function normally.Replace inlet filter. p.24
Continuous air exhaustWorn or damaged piston o-ring or valve cup.Service air motor / valve p.24
Continuous air exhaustDamaged valve gasketReplace valve gasket. p.24
Continuous air exhaustLower air pressure to prevent reoc- currence. p.24
Pump operates but output is lowHeld open or worn intake valveClear; service. p.24
Pump operates but output is lowHeld open or worn pump piston packingsClear; service. p.24
Pump operates but output is lowThe muffler is partially blockedClear muffler. p.24
Pump operates but output is lowThe inlet filter is partially blockedClear the filter. p.24
Pump operates but output is lowInadequate air supply pressure or restricted air linesIncrease air supply; clear restric- tions. p.24
Pump operates but output is lowPartially closed or clogged pilot valvesOpen valves. Clear clog as neces- sary. p.24
Pump operates but output is lowPartially clogged fluid line, hose, valves, etc.Clear clog as necessary. p.24
Oil leakage through air exhaustsThroat seal is damagedReplace throat seal (u-cup). p.24

Ask about the Graco 3A1334F

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 3A1334F

Be the first to ask — other owners or our team will answer.

Original document

Graco 3A1334F manual PDF

32 pages·1.9 MB·Water Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…