Husky ® 1050 Air-Operated Diaphragm Pump
1-inch pump with modular air valve for fluid transfer applications. For professional use only.
See page 4 for model information, including approvals.
125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure 125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure



To Find Your Nearest Distributor
Please call your distributor.
Please call your distributor.
a. Use the 20-digit number from the ID plate on the pump. If you only have the Graco 6-digit part number, use the selector tool to find the corresponding 20-digit number.
b. Use the Configuration Number Matrix on the next page to understand which parts are described by each digit.
c. Use the Repair/Parts Manual. Refer to the main Parts illustration and to the Parts/Kits Quick Reference. Follow the page references on these two pages for further ordering information, as needed.

Check the identification plate (ID) for the 20-digit Configuration Number of your pump. Use the following matrix to define the components of your pump.
CONFIGURATION NO. PART NO. SERIAL NO.
SERIES DATE CODE MAX WPR PSI-bar MADE IN
Configuration Number Matrix · Pump Configuration Number

★ All 1050A (Aluminum) and 1050C (Conductive Polypropylene) pumps are certified:
‡ 1050S (Stainless Steel) and 1050H (Hastelloy) pumps with aluminum or conductive polypropylene centers are certified:
✖ DataTrak and Pulse Count are certified:
II 2 GD c IIC T4
II 2 GD c IIC T4
Ex ia IIA T3 Ga ITS13ATEX27862X
9902471 Class I, Div. 1,
The following warnings are for the setup, use, grounding, maintenance, and repair of this equip- ment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. When these symbols appear in the body of this manual, refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.
ATEX Certifications · Group D T3A

THERMAL EXPANSION HAZARD Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure due to the thermal expansion. Over-pressurization can result in equipment rupture and serious injury.

PLASTIC PARTS CLEANING SOLVENT HAZARD Use only compatible water-based solvents to clean plastic structural or pressure-con- taining parts. Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage. See Technical Data in this and all other equipment instruction manuals. Read fluid and solvent manufacturer’s warnings.
The Typical Installation shown in FIG. 4 is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.
Before using the pump for the first time, check and retorque all external fasteners. Follow Torque Instructions, page 17.

wire to a true earth ground. A ground wire and clamp, Part 238909, is available from Graco.
Polypropylene and PVDF: Only aluminum, conductive polypropylene, hastelloy, and stainless steel pumps have a ground screw. Standard polypropylene and PVDF pumps are not conductive. Never use a non-conduc- tive polypropylene or PVDF pump with non-conductive flammable fluids. Follow your local fire codes. When pumping conductive flammable fluids, always ground the entire fluid system as described.

Air and fluid hoses: Use only grounded hoses with a maximum of 500 ft (150 m) com- bined hose length to ensure grounding conti- nuity.

Air compressor: Follow manufacturer’s recommendations.
The equipment must be grounded to reduce the risk of static sparking. Static sparking can cause fumes to ignite or explode. Grounding provides an escape wire for the electric current.
Fluid supply container: Follow local code.
Solvent pails used when flushing: Follow local code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts ground- ing continuity.
Pump: See FIG. 1. Loosen the grounding screw (GS). Insert one end of a 12 ga. minimum ground wire (R) behind the grounding screw and tighten the screw securely. Connect the clamp end of the ground

Check your system electrical continuity after the initial installation, and then set up a regular schedule for checking continuity to be sure proper grounding is maintained.

See FIG. 4, page 12.


Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing.
Pulse Count models are intended for use with customer-supplied fluid management or inven- tory tracking systems. Attach an M12, 5-pin female cable to connect the reed switch to your data monitoring system. See Manual 406824.
ti16894a

The air exhaust port is 3/4 npt(f). Do not restrict the air exhaust port. Excessive exhaust restriction can cause erratic pump operation.
Key: A Air supply line B Bleed-type master air valve C Air filter/regulator assembly D Air inlet E Master air valve (for accessories) T Muffler U Grounded air exhaust hose V Container for remote air exhaust

F IG . 3. Vent exhaust air
ti14219b

Fluid Outlet Line
See FIG. 4, page 12.
See FIG. 4, page12.


F IG . 4. Typical floor-mount installation (polypropylene, 1050P, pump shown)
Key for F IG . 4:
N Fluid outlet (Aluminum, not pictured, four ports; Plastic, FIG. 4, center or end flanges available; Hastelloy and stainless steel, not pictured, one port) R Ground wire (required for aluminum, conductive polypropylene, hastelloy, and stainless steel pumps; see page 8 for installation instructions)
A Air supply line B Bleed-type master air valve (required for pump) C Air filter/regulator assembly D Air inlet E Master air valve (for accessories) G Grounded, flexible fluid supply line J Fluid drain valve (required) K Fluid shutoff valve L Grounded, flexible fluid outlet line M Fluid inlet (Aluminum, not pictured, four ports; Plastic, FIG. 4, center or end flanges available; Hastelloy and stainless steel, not pictured, one port)
ti14164b

Graco standard pipe flange kits are available in polypropylene (239005), stainless steel (239008), and PVDF (239009). These kits include:
The fluid inlet and outlet manifolds each have four 1 in. npt(f) or bspt threaded ports. Close off the unused ports, using the supplied plugs.
Be sure to lubricate the threads of the bolts and torque to 10-15 ft-lb (14-20 N•m). Follow the bolt tightening sequence and do not over-torque.
The fluid inlet and outlet manifolds each have a 1 in. raised face ANSI/DIN flange (FIG. 4, M, N) in either a center or end location. Connect 1 in. standard flanged plastic pipe to the pump. See FIG. 5.
The fluid inlet and outlet manifolds each have one 1 in. npt (f) or bspt threaded port.

Key: M 1 in. fluid inlet flange N 1 in. fluid outlet flange S 1 in. standard pipe flange T PTFE gasket U Flat washer V Nut W Lock washer X Bolt
1 Torque to 10-15 ft-lb (14-20 N•m). Do not over-torque.
FIG. 5. Flange connections (plastic pumps only, 1050P, 1050C, and 1050F models)

Some systems may require installation of a pressure relief valve at the pump outlet to pre- vent overpressurization and rupture of the pump or hose.
Overpressurization also can occur if the Husky pump is used to feed fluid to a piston pump, and the intake valve of the piston pump does not close, causing fluid to back up in the outlet line.
Thermal expansion of fluid in the outlet line can cause overpressurization. Thermal expansion can occur when using long fluid lines exposed to sunlight or ambient heat, or when pumping from a cool to a warm area (for example, from an underground tank).
FIG. 6 shows Fluid Pressure Relief Kit 238428 for aluminum pumps. Use Fluid Pressure Relief Kit 112119, not shown, for plastic pumps.
Apply thread sealant on threaded connec- tions and install kit between fluid inlet and outlet manifolds.

Connect fluid inlet line in one of the optional ports. 2
Connect fluid outlet line in one of the optional ports. 3
FIG. 6. Fluid pressure relief kit (Aluminum pumps only, 1050A models)
ti14214b

Pressure Relief Procedure
Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing.
The pump was tested in water. If water could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. See Flushing and Storage, page 16.
Before using the pump for the first time, check and retorque all external fasteners. Follow Torque Instructions, page 17. After the first day of operation, retorque the fasteners.
Operation

10.If you are flushing, run the pump long enough to thoroughly clean the pump and hoses.
Before each use, check all hoses for wear or damage and replace as necessary. Check to be sure all threaded connections are tight and leak-free. Check fasteners. Tighten or retorque as necessary. Although pump use varies, a general guideline is to retorque fasteners every two months. See Torque Instructions, page 17.
11.Close the dispensing valve, if used.
12.Close the bleed-type master air valve.
DataTrak Operation
See DataTrak manual 313840 for all DataTrak information and parts, including detailed oper- ation instructions.
At the end of the work shift and before you check, adjust, clean or repair the system, fol- low Pressure Relief Procedure, page 15.
Flush the pump often enough to prevent the fluid you are pumping from drying or freezing in the pump and damaging it. Use a compati- ble solvent.
Maintenance Schedule
Always flush the pump and relieve the pres- sure before storing it for any length of time.
Establish a preventive maintenance schedule, based on the pump’s service history. Sched- uled maintenance is especially important to prevent spills or leakage due to diaphragm failure.
The pump is lubricated at the factory. It is designed to require no further lubrication for the life of the pump. There is no need to add an inline lubricator under normal operating conditions.
Maintenance


If fluid cover or manifold fasteners have been loosened, it is important to torque them using the following procedure to improve sealing.
Start all fluid cover screws a few turns. Then turn down each screw just until head contacts cover. Then turn each screw by 1/2 turn or less working in a crisscross pattern to specified torque. Repeat for manifolds.

100 in-lb (11.3 N•m)
Retorque the air valve fasteners (V) in a criss- cross pattern to specified torque.
Maintenance · ti18448a · ti18449a

Aluminum ( 1050A )




A 12.7 in. (323 mm) B 14.4 in. (366 mm) C 15.9 in. (404 mm) D 10.9 in. (277 mm) E 1.8 in. (46 mm) F 7.3 in. (185 mm) G 14.7 in. (373 mm) H 6.2 in. (158 mm)
J 3.9 in. (99 mm) K 10.2 in. (258 mm) L 1/2 npt(f) air inlet M 1 in. npt(f) or 1 in. bspt fluid
inlet ports (4) N 1 in. npt(f) or 1 in. bspt fluid
outlet ports (4) P 3/4 npt(f) air exhaust port
Dimensions and Mounting

Polypropylene (1050P), Conductive Polypropylene (1050C) and PVDF (1050F)



J 3.9 in. (99 mm) K 10.2 in. (258 mm) L 1/2 npt(f) air inlet M 1 in. ANSI/DIN flange N 1 in. ANSI/DIN flange P 3/4 npt(f) air exhaust port
A 13.2 in. (335 mm) B 15.7 in. (399 mm) C 17.8 in. (452 mm) D 12.0 in. (305 mm) E 2.5 in. (63.5 mm) F 8.0 in. (203 mm) G Center Flange: 16.0 in. (406 mm)
Dimensions and Mounting · ti13845b ti13847b





A 11.8 in. (300 mm) B 12.9 in. (328 mm) C 13.7 in. (348 mm) D 9.5 in. (241 mm) E 1.1 in. (28 mm) G 13.9 in. (353 mm) H 6.2 in. (158 mm) J 4.0 in. (102 mm) K 10.2 in. (258 mm)
L 1/2 npt(f) air inlet M 1 in. npt(f) or 1 in. bspt fluid inlet
ports (4) N 1 in. npt(f) or 1 in. bspt fluid outlet
ports (4) P 3/4 npt(f) air exhaust port
Dimensions and Mounting

Test Conditions: Pump tested in water with inlet submerged.
28 56 84 112 140 168 196 224 252 280
(0.83. 8.3)
Fluid Pressure - psi (MPa, bar)
(0.7, 7.0)
(0.55, 5.5)
(0.41, 4.1)
A 125 psi (0.83 MPa, 8.3 bar) B 100 psi (0.7 MPa, 7.0 bar) C 70 psi (0.48 MPa, 4.8 bar) D 40 psi (0.28 MPa, 2.8 bar)
(0.28, 2.8)
(0.14, 1.4)
0 5 10 15 20 25 30 35 40 45 50 (19) (38) (57) (76) (95) (114) (133) (152) (170) (189)
Fluid Flow — gpm (lpm)
How to Read the Charts
28 56 84 112 140 168 196 224 252 280
Air Consumption - scfm (cubic meters/min.)
(2.24)
A
(1.68)
(1.12)
(0.56)
0 5 10 15 20 25 30 35 40 45 50 (19) (38) (57) (76) (95) (114) (133) (152) (170) (189) Fluid Flow — gpm (lpm)

Maximum fluid working pressure 125 psi (0.86 MPa, 8.6 bar) Air pressure operating range 20-125 psi (0.14-0.86 MPa, 1.4-8.6 bar) Fluid displacement per cycle 0.17 gal. (0.64 liters) Air consumption at 70 psi (0.48 MPa, 4.8 bar), 20 gpm (76 lpm) 25 scfm Maximum values with water as media under submerged inlet conditions at ambient temperature:
Maximum air consumption Maximum free-flow delivery Maximum pump speed Maximum suction lift (varies widely based on ball/seat selection and wear, operating speed, material properties, and other variables)
67 scfm 50 gpm (189 lpm) 280 cpm
16 ft (4.9 m) dry, 29 ft (8.8 m) wet Maximum size pumpable solids 1/8 in. (3.2 mm) Recommended cycle rate for continuous use 93 - 140 cpm Recommended cycle rate for circulation systems 20 cpm Sound Power*
78 dBa 90 dBa Sound Pressure**
at 70 psi (0.48 MPa, 4.8 bar) and 50 cpm at 100 psi (0.7 MPa, 7.0 bar) and full flow
84 dBa 96 dBa Fluid temperature range see page 23 Air inlet size 1/2 npt(f) Fluid inlet size
at 70 psi (0.48 MPa, 4.8 bar) and 50 cpm at 100 psi (0.7 MPa, 7.0 bar) and full flow
1 in. npt(f) or 1 in. bspt 1 in. raised face ANSI/DIN flange Fluid outlet size
Aluminum (1050A), Hastelloy (1050H) or Stainless Steel (1050S) Conductive Poly (1050C), Polypropylene (1050P), or PVDF (1050F) . . .
1 in. npt(f) or 1 in. bspt 1 in. raised face ANSI/DIN flange Weight
Aluminum (1050A), Hastelloy (1050H) or Stainless Steel (1050S) Conductive Poly (1050C), Polypropylene (1050P), or PVDF (1050F) . . .
Aluminum (1050A) Conductive Polypropylene (1050C) and Polypropylene (1050P) Hastelloy PVDF (1050F) Stainless Steel (1050S)
23 lb. (10.5 kg) 18 lb. (8.2 kg) 41 lb. (18.6 kg) 26 lb (11.8 kg)
36.3 lb. (16.5 kg) 37.3 lb. (16.9 kg) 41.4 lb. (18.8 kg) Wetted parts include material(s) chosen for seat, ball, and diaphragm options, plus the pump’s material of construction
with conductive polypropylene center with polypropylene center with aluminum center
1050A 1050H 1050C and 1050P 1050F 1050S
Aluminum Hastelloy Polypropylene PVDF Stainless Steel
Technical Data

aluminum, coated carbon steel hastelloy, stainless steel, polypropylene or aluminum (if used in center section) stainless steel, polypropylene stainless steel, polypropylene or alumi- num (if used in center section) Reference Information
Aluminum (1050A) Hastelloy (1050H)
Plastic (1050P, 1050C, and 1050F) Stainless Steel (1050S)
Maximum Storage Time (varies with conditions) Maximum Lifetime (varies with operating conditions and maintenance) . Power Efficiency Factor (varies based on pump configuration, operating parameters, and material)
2 years 10 years
1.61 gal. air consumed/1 gal. fluid pumped at 70 psi (1.61 liter air con- sumed/1 liter fluid pumped at 4.8 bar)
* Sound power measured per ISO-9614-2. ** Sound pressure was tested 3.28 ft (1 m) from equipment.
All trademarks mentioned in this manual are the property of their respective owners.
Conductive Polypropylene Pumps PVDF Pumps
Fahrenheit Celsius Fahrenheit Celsius Fahrenheit Celsius
Acetal (AC) 10° to 180°F -12° to 82°C 32° to 150°F 0° to 66°C 10° to 180°F -12° to 82°C Buna-N (BN) 10° to 180°F -12° to 82°C 32° to 150°F 0° to 66°C 10° to 180°F -12° to 82°C FKM Fluoroelastomer (FK)* -40° to 275°F -40° to 135°C 32° to 150°F 0° to 66°C 10° to 225°F -12° to 107°C
Geolast® (GE) -40° to 150°F -40° to 66°C 32° to 150°F 0° to 66°C 10° to 150°F -12° to 66°C
0° to 180°F -18° to 82°C 32° to 150°F 0° to 66°C 10° to 180°F -12° to 82°C
diaphragm (CO) or Poly- chloroprene check balls (CR or CW)
Polypropylene (PP) 32° to 150°F 0° to 66°C 32° to 150°F 0° to 66°C 32° to 150°F 0° to 66°C PTFE overmolded
40° to 180°F 4° to 82°C 40° to 150°F 4° to 66°C 40° to 180°F 4.0° to 82°C
diaphragm (PO)
PTFE check balls or two-piece PTFE/EPDM diaphragm (PT)
40° to 220°F 4° to 104°C 40° to 150°F 4° to 66°C 40° to 220°F 4° to 104°C
PVDF (PV) 10° to 225°F -12° to 107°C 32° to 150°F 0° to 66°C 10° to 225°F -12° to 107°C
Santoprene® (SP) -40° to 180°F -40° to 82°C 32° to 150°F 0° to 66°C 10° to 180°F -12° to 82°C
TPE (TP) -20° to 150°F -29° to 66°C 32° to 150°F 0° to 66°C 10° to 150°F -12° to 66°C
* The maximum temperature listed is based on the ATEX standard for T4 temperature classification. If you are operating in a non-explosive environment, FKM fluoroelastomer’s maximum fluid temperature in aluminum or stainless steel pumps is 320°F (160°C).

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of five years from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within six (6) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com For patent information, see www.graco.com/patents
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 312877
Copyright 2009, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Revision P, July 2014