Reactor 2 E-30 and E-XP2
Proportioning System 333024F EN
Electric, Heated, Plural Component Proportioning System. For spraying polyurethane foam and polyurea coatings. For professional use only. Not approved for use in explosive atmospheres or hazardous locations.

PROVEN QUALITY. LEADING TECHNOLOGY.


The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.



Equipment surfaces and fluid that is heated can become very hot during operation. To avoid severe burns:

Isocyanates (ISO) are catalysts used in two component materials.
Spraying or dispensing fluids that contain isocyanates creates potentially harmful mists, vapors, and atomized particulates.


Moisture Sensitivity of Isocyanates
Exposure to moisture (such as humidity) will cause ISO to partially cure, forming small, hard, abrasive crystals that become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity.
Some materials may become self-igniting if applied too thick. Read material manufacturer’s warnings and SDS.
Partially cured ISO will reduce performance and the life of all wetted parts.
Cross-contamination can result in cured material in fluid lines which could cause serious injury or damage to equipment. To prevent cross-contamination:
Changing the material types used in your equipment requires special attention to avoid equipment damage and downtime.
Some foam blowing agents will froth at temperatures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system.

All elite systems include fluid inlet pressure and temperature sensors, Graco InSite™, and Xtreme-Wrap 50 ft (15 m) head hose. For part numbers, see Accessories, page 11
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.
Packages include gun, heated hose, and whip hose. Elite packages also include Graco InSite and fluid inlet sensors.
Low line input voltage will reduce power available and heaters will not perform at full capacity.
Total system watts used by system, based on maximum heated hose length for each unit.
★ See Approvals, page 11.
Models

All elite systems include fluid inlet pressure and temperature sensors, Graco InSite™, and Xtreme-Wrap 50 ft (15 m) head hose. For part numbers, see Accessories, page 11
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.
Packages include gun, heated hose, and whip hose. Elite packages also include Graco InSite and fluid inlet sensors.
Low line input voltage will reduce power available and heaters will not perform at full capacity.
Total system watts used by system, based on maximum heated hose length for each unit.
★ See Approvals, page 11.
Models

Accessories
Intertek approvals apply to proportioners without hoses.
Proportioner Approvals:
Conforms to ANSI/UL Std. 499 Certified to CAN/CSA Std. C22.2 No. 88
Approvals · 9902471

The following manuals are shipped with the Reactor 2. Refer to these manuals for detailed equipment information.
Manuals are also available at www.graco.com
The following manuals are for accessories used with the Reactor.
Manuals are available at www.graco.com
Supplied Manuals


There are three types of errors that can occur. Errors are indicated on the display as well as by the light tower (optional).
A parameter critical to the process has reached a level requiring the system to stop. The alarm needs to be addressed immediately.
to return to the previously displayed screen.
A parameter critical to the process has reached a level requiring attention, but not sufficient enough to stop the system at this time.

A parameter that is not immediately critical to the process. The advisory needs attention to prevent more serious issues in the future.
See Error Codes, page 13 for causes and solutions to each error code.
To troubleshoot the error:
When an error occurs be sure to determine the code before resetting it. If you forget which error code occurred, see the Errors screen to view the last 200 errors, with date, time, and description.

Error Location Type Description Cause Solution
Loose/broken connection.
Check for loose wire terminations at MCM motor connector.
Bad Motor. Disconnect motor output connector from MCM. Confirm less than 8 ohms resistance between each pair of motor power leads (M1 to M2, M1 to M3, M2 to M3). If any readings greater than 8 ohms, check motor wiring for damage and/or loose terminations.
Check wiring for touching wires. A4DA Heater A
Short circuit in heater wiring.
Bad Heater. Confirm resistance of heater. Heater resistance should be 18–21 Ω for each heater element, 9–12 Ω combined for 10 kW systems, and 6-8 Ω for 15 kW systems. If out of tolerance, replace heater element.
Check wiring for touching wires. A4DB Heater B
Short circuit in heater wiring.
Bad Heater. Confirm resistance of heater. Heater resistance should be 9-12 Ω for 10 kW systems and 6-8 Ω for 15 kW systems. If out of tolerance, replace heater.
High Current Hose Short circuit in hose wiring.
Check continuity of transformer windings. Normal readings are about 0.2Ω on both primary and secondary. If reading is 0Ω replace transformer.
Check for shorts between the primary winding and the support frame or enclosure.

Error Location Type Description Cause Solution
Short circuit of motor wiring.
Check wiring to the motor to ensure no bare wires are touching and that no wires are shorted to ground.
Motor will not rotate.
Remove pump gear housings from motor and check that motor shaft rotates freely in direction indicated on motor housing.
Damaged gear train.
Check pump gear trains for damage and repair or replace as necessary.
Chemical pump is stuck.
Repair or replace chemical pump.
Shorted TCM If error cannot be cleared or regenerates consistently, replace module.
Shorted TCM If error cannot be cleared or regenerates consistently, replace module.
Shorted TCM If error cannot be cleared or regenerates consistently, replace module.

Error Location Type Description Cause Solution
Tripped circuit breaker.
Visually check circuit breaker for a tripped condition.
Loose/broken connection.
Check heater wiring for loose wires.
Tripped circuit breaker.
Visually check circuit breaker for a tripped condition.
Loose/broken connection.
Check heater wiring for loose wires.
Tripped circuit breaker.
Visually check circuit breaker for a tripped condition.
Loose/broken connection.
Check heater wiring for loose wires.
Module does not have software.
Insert a system token into the ADM module and cycle the power. Wait until the upload is complete before removing the token.
Dial set to wrong position.
Ensure the MCM dial is set to the correct position: 2 for E-30, 3 for E-XP2
No 24 VDC supply to module.
Green light on each module should be lit. If green light is not lit, check to make sure each CAN cable connection is tight. Verify the power supply is outputting 24 VDC. If not, check power supply wiring. If wiring is okay, replace the power supply.
Loose or broken CAN cable.
Check the CAN cables running between GCA modules and tighten of needed. If the problem still persists move each cable around the connector and watch the flashing yellow light on the GCA modules. If the yellow light stops flashing, replace the CAN cable.

Error Location Type Description Cause Solution
Module does not have software.
Insert a system token into the ADM module and cycle the power. Wait until the upload is complete before removing the token.
No 24 VDC supply to module.
Green light on each module should be lit. If green light is not lit, check to make sure each CAN cable connection is tight. Verify the power supply is outputting 24 VDC. If not, check power supply wiring. If wiring is okay, replace the power supply.
Loose or broken CAN cable.
Check the CAN cables running between GCA modules and tighten of needed. If the problem still persists move each cable around the connector and watch the flashing yellow light on the GCA modules. If the yellow light stops flashing, replace the CAN cable.
Pump Runaway Flow rate is too large.
Mix chamber too large for system selected. Use mix chamber rated for system.
Ensure the system has chemical and the feed pumps are operating correctly.
No material in pumps. Verify pumps are supplying chemical. If necessary, replace or refill drums.
Inlet ball valves are closed. Open ball valves.
Check wiring between cycle switch and MCM. DE0X MCM
Faulty or missing cycle switch.
Missing or out of place cycle switch magnet.
Check presence and position of cycle switch magnet on output crank arm.
TCM Communication Error · Cycle Switch Error

Error Location Type Description Cause Solution
Manual Hose Mode Enabled
Manual hose mode has been enabled in System Setup screen.
Install a functioning fluid temperature sensor (FTS) on the hose. Manual hose mode will automatically turn off.
USB Busy USB drive has been inserted to the ADM.
Do not remove USB drive until download/upload is complete.
USB disabled USB download/uploads are disabled.
Enable USB download/up- loads on the Advanced Setup screen before insert- ing a USB drive.
Mix chamber is too large for set pressure.
Reference the pressure flow curves and select a tip size that is the correct size for the set pressure.
Low Frequency A Line frequency is below 45 Hz
Ensure line frequency of incoming power is between 45 and 65 Hz.
Low Frequency B Line frequency is below 45 Hz
Ensure line frequency of incoming power is between 45 and 65 Hz.
Low Frequency Hose Line frequency is below 45 Hz
Ensure line frequency of incoming power is between 45 and 65 Hz.
High Frequency A Line frequency is above 65 Hz
Ensure line frequency of incoming power is between 45 and 65 Hz.
High Frequency B Line frequency is above 65 Hz
Ensure line frequency of incoming power is between 45 and 65 Hz.
Line frequency is above 65 Hz
Ensure line frequency of incoming power is between 45 and 65 Hz.
Motor will not rotate.
Remove pump gear housings from motor and check that motor shaft rotates freely in direction indicated on motor housing.
Damaged gear train.
Check motor/pump gear trains for damage and repair or replace as necessary.
Chemical pump is stuck.
Repair or replace chemical pump.

Error Location Type Description Cause Solution
Low Chemical Level A
Low material level. Refill material and update drum level on ADM Maintenance screen.
Alarm can be disabled on the System Setup screen.
Low Chemical Level B
Low material level. Refill material and update drum level on ADM Maintenance screen.
Alarm can be disabled on the System Setup screen.
Maintenance Due - USB
USB logs have reached a level where data loss will occur if logs are not downloaded.
Insert a USB drive into the ADM and download all logs.
Pressure Imbalance A High
Pressure difference between A and B material is greater than the defined value.
Ensure material flow is equally restricted on both material lines.
Pressure imbalance is defined too low.
Ensure that the pressure imbalance value, on the System Setup screen, is at an acceptable maximum pressure to prevent unnecessary alarms and abort dispenses.
Out of material. Fill tanks with material
Fluid leaking from heater inlet rupture disk.
Check if heater and PRESSURE RELIEF/SPRAY valve are plugged. Clear. Replace rupture disk. Do not replace with a pipe plug.
Feed system defective.
Check feed pump and hoses for blockage. Check that feed pumps have correct air pressure.

Error Location Type Description Cause Solution
Pressure Imbalance B High
Pressure difference between A and B material is greater than the defined value.
Ensure material flow is equally restricted on both material lines.
Pressure imbalance is defined too low.
Ensure that the pressure imbalance value, on the System Setup screen, is at an acceptable maximum pressure to prevent unnecessary alarms and abort dispenses.
Out of material. Fill tanks with material
Fluid leaking from heater inlet rupture disk.
Check if heater and PRESSURE RELIEF/SPRAY valve are plugged. Clear. Replace rupture disk. Do not replace with a pipe plug.
Feed system defective.
Check feed pump and hoses for blockage. Check that feed pumps have correct air pressure.
Ensure that inlet pressure to the pump is sufficient. P1FA MCM
Low Inlet Pressure A
Inlet pressure lower than defined value.
Value defined too high.
Ensure that the low pressure alarm level defined on the System Setup screen is acceptable.
Ensure that inlet pressure to the pump is sufficient. P1FB MCM
Low Inlet Pressure B
Inlet pressure lower than defined value.
Value defined too high.
Ensure that the low pressure alarm level defined on the System Setup screen is acceptable.
Ensure that inlet pressure to the pump is sufficient. P2FA MCM
Low Inlet Pressure A
Inlet pressure lower than defined value.
Value defined too high.
Ensure that the low pressure alarm level defined on the System Setup screen is acceptable.

Error Location Type Description Cause Solution
Ensure that inlet pressure to the pump is sufficient. P2FB MCM
Low Inlet Pressure B
Inlet pressure lower than defined value.
Value defined too high.
Ensure that the low pressure alarm level defined on the System Setup screen is acceptable.
System pressurized before allowing heat to reach setpoint.
Pressure in the hose and pumps will increase as the system heats up. Turn on heat and allow all zones to reach the temperature setpoint before turning on the pumps.
Bad pressure transducer.
Verify the ADM pressure reading and the analog gauges at the manifold.
E-XP2 system configured as E-30.
Alarm level is lower for E-30 than for E-XP2. Ensure dial on MCM is set to position "3" for E-XP2.
System pressurized before allowing heat to reach setpoint.
Pressure in the hose and pumps will increase as the system heats up. Turn on heat and allow all zones to reach the temperature setpoint before turning on the pumps.
Bad pressure transducer.
Verify the ADM pressure reading and the analog guages at the manifold.
E-XP2 system configured as E-30.
Alarm level is lower for E-30 than for E-XP2. Ensure dial on MCM is set to position "3" for E-XP2.
High Pressure A · High Pressure B

Error Location Type Description Cause Solution
Pressure Sensor Error A
Loose/bad connection.
Check to ensure the pressure transducer is properly installed and all wires are properly connected.
Bad sensor. Check if the error follows the transducer. Disconnect transducer cables from the MCM (connectors 6 and 7). Reverse A and B connections and check if the errors follows. If the error follows the transducer, replace the pressure transducer.
Pressure Sensor Error B
Loose/bad connection.
Check to ensure the pressure transducer is properly installed and all wires are properly connected.
Bad sensor. Check if the error follows the transducer. Disconnect transducer cables from the MCM (connectors 6 and 7). Reverse A and B connections and check if the errors follows. If the error follows the transducer, replace the pressure transducer.
Pressure Sensor Error Inlet A
Inlet sensors not installed.
If inlet sensors are not installed, inlet sensors should be disabled on the System Setup screen.
Loose/bad connection.
Check to ensure inlet sensor is properly installed and all wires are properly connected.
Bad sensor. Check if the error follows the inlet sensor. Disconnect inlet sensor cables from the MCM (connectors 8 and 9). Reverse A and B connections and check if the errors follows. If the error follows the sensor, replace the inlet sensor.

Error Location Type Description Cause Solution
Pressure Sensor Error Inlet B
Inlet sensors not installed.
If inlet sensors are not installed, inlet sensors should be disabled on the System Setup screen.
Loose/bad connection.
Check to ensure inlet sensor is properly installed and all wires are properly connected.
Bad sensor. Check if the error follows the inlet sensor. Disconnect inlet sensor cables from the MCM (connectors 8 and 9). Reverse A and B connections and check if the errors follows. If the error follows the sensor, replace the inlet sensor.
Pressure Imbalance A High
Pressure difference between A and B material is greater than the defined value.
Ensure material flow is equally restricted on both material lines.
Pressure imbalance is defined too low.
Ensure that the pressure imbalance value, on the System Setup screen, is at an acceptable maximum pressure to prevent unnecessary alarms and abort dispenses.
Out of material. Fill tanks with material
Fluid leaking from heater inlet rupture disk.
Check if heater and PRESSURE RELIEF/SPRAY valve are plugged. Clear. Replace rupture disk. Do not replace with a pipe plug.
Feed system defective.
Check feed pump and hoses for blockage. Check that feed pumps have correct air pressure.

Error Location Type Description Cause Solution
Pressure Imbalance B High
Pressure difference between A and B material is greater than the defined value.
Ensure material flow is equally restricted on both material lines.
Pressure imbalance is defined too low.
Ensure that the pressure imbalance value, on the System Setup screen, is at an acceptable maximum pressure to prevent unnecessary alarms and abort dispenses.
Out of material. Fill tanks with material
Fluid leaking from heater inlet rupture disk.
Check if heater and PRESSURE RELIEF/SPRAY valve are plugged. Clear. Replace rupture disk. Do not replace with a pipe plug.
Feed system defective.
Check feed pump and hoses for blockage. Check that feed pumps have correct air pressure.
Flow is too high at current setpoint.
Use a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint.
Bad RTD or bad RTD placement against heater.
Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.
Bad heater rod or loose heater wire.
Confirm resistance of heater. Heater resistance should be 9-12 Ω for 10 kW systems and 6-8 Ω for 15 kW systems. If out of tolerance, check for loose heater rod wire(s). Reconnect wires or replace heater rod if necessary.
T2DA Heater A · Low Temperature A

Error Location Type Description Cause Solution
Flow is too high at current setpoint.
Use a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint.
Bad RTD or bad RTD placement against heater.
Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.
Bad heater rod or loose heater wire.
Confirm resistance of heater. Heater resistance should be 9-12 Ω for 10 kW systems and 6-8 Ω for 15 kW systems. If out of tolerance, check for loose heater rod wire(s). Reconnect wires or replace heater rod if necessary.
Flow is too high at current setpoint.
Use a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint.
Cold chemical in unheated portion of system passed hose FTS at startup.
Recirculate heated chemical back to drum in cold conditions before startup.
Low Temperature Inlet A
Inlet fluid temperature is below the defined level.
Recirculate fluid through heaters until inlet fluid temperature is above defined error level.
Increase the low temperature deviation level on the System Setup screen.
Low Temperature Inlet B
Inlet fluid temperature is below the defined level.
Recirculate fluid through heaters until inlet fluid temperature is above defined error level.
Increase the low temperature deviation level on the System Setup screen.

Error Location Type Description Cause Solution
Hose Cutback Hose current has been reduced because hose has been drawing current for an extended period.
Hose setpoint higher than A and B setpoints. Decrease hose setpoint.
Hose FTS is in a colder environment than the rest of the hose. Expose FTS to the same environment as the rest of the hose.
High ambient temperature.
Ensure ambient temperature is below 120°F(48°C) before using the system.
Enclosure fan not operating.
Ensure fan in electrical enclosure is spinning. If it is not, check fan wiring or replace fan.
Module fan not operating.
If a TCM fan error (WMI0) has occurred, fan inside the module is not working properly. Check TCM fan for debris and clear with forced air if necessary.
Motor is operating outside of the pressure flow curve.
The system is running at a lower setpoint to preserve motor life. Run the system at a lower duty cycle or with a smaller mix chamber.
Motor temperature is too high.
Ensure ambient temperature is below 120°F(48°C).
Verify that all fans are working.
Motor control temperature is too high.
Ensure ambient temperature is below 120°F(48°C).
Verify that all fans are working.
High ambient temperature.
Ensure ambient temperature is below 120°F(48°C) before using the system.
Enclosure fan not operating.
Ensure fan in electrical enclosure is spinning. If it is not, check fan wiring or replace fan.

Error Location Type Description Cause Solution
High ambient temperature.
Ensure ambient temperature is below 120°F(48°C) before using the system.
Enclosure fan not operating.
Ensure fan in electrical enclosure is spinning. If it is not, check fan wiring or replace fan.
Module fan not operating.
If a TCM fan error (WMI0) has occurred, fan inside the module is not working properly. Check TCM fan for debris and clear with forced air if necessary.
Bad RTD or bad RTD placement against heater.
Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.
Flow too high for temperature setpoint, causing temperature overshoots when gun is de-triggered.
Use a smaller mix chamber that is rated for the unit in use.
Bad RTD or bad RTD placement against heater.
Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.
Flow too high for temperature setpoint, causing temperature overshoots when gun is de-triggered.
Use a smaller mix chamber that is rated for the unit in use.

Error Location Type Description Cause Solution
Hose portion exposed to an excessive heat source, like hot sun or coiled hose, can pass fluid more than 27°F (15°C) over hose temperature setting to the FTS.
Shade exposed hose from hot sun or expose FTS to same environment when at rest. Uncoil entire hose before heating to avoid self-heating.
Setting the A or B setpoint much higher than hose setpoint can cause fluid more than 27°F (15°C) over hose temperature setting to reach the FTS.
Increase hose setpoint so it is closer to A and B setpoints.
High Temperature Switch A
Overtemperature switch sensed a fluid temperature above 230°F (110°C).
Heater was delivered too much power, causing the overtemperature switch to open. RTD is not reading properly. After the heater cools down, replace RTD. Switch closes and the error can be cleared when the heater temperature falls below 190°F (87°C).
Disconnected or loose overtemperature switch cable/connection.
If heater is not actually over temperature, check all wiring and connections between the TCM and the overtemperature switches.
Overtemperature switch failed in the open position.
Replace overtemperature switch.
T4DH Hose · High Temperature Hose · T4EA Heater A

Error Location Type Description Cause Solution
High Temperature Switch B
Overtemperature switch sensed a fluid temperature above 230°F (110°C).
Heater was delivered too much power, causing the overtemperature switch to open. RTD is not reading properly. After the heater cools down, replace RTD. Switch closes and the error can be cleared when the heater temperature falls below 190°F (87°C).
Disconnected or loose overtemperature switch cable/connection.
If heater is not actually over temperature, check all wiring and connections between the TCM and the overtemperature switches.
Overtemperature switch failed in the open position.
Replace overtemperature switch.
Cooling fan is not operating properly.
Check to see that the motor fan is moving. Measure voltage to fan. There should be 24 VDC. If no voltage is measured, check fan wiring. If the fan has voltage but is not moving, replace fan. If necessary use an air hose to blow out around the fan housings and remove any built-up debris.
Disconnected or loose motor temperature cable.
Verify wiring between the motor temperature sensor and the MCM.
High ambient temperature.
Ensure ambient temperature is below 120°F(48°C) before using the system.
Bad electric motor. Replace electric motor.
Check all wiring and connection to RTD. T6DA Heater A
Disconnected or loose RTD cable or connection.
Bad RTD. Switch the RTD with another and see if the error message follows the RTD. Replace RTD if the error follows the RTD.
T4EB Heater B · High Temperature Motor · Sensor Error A

Error Location Type Description Cause Solution
Check all wiring and connection to RTD. T6DB Heater B
Disconnected or loose RTD cable or connection.
Bad RTD. Switch the RTD with another and see if the error message follows the RTD. Replace RTD if the error follows the RTD.
Sensor Error Hose Disconnected or shorted RTD cable in hose or bad FTS.
Expose each hose RTD connection to check and retighten any loose con- nector. Measure hose RTD cable and FTS continuity. See Repair Heated Hose, page 64. Order RTD Test kit 24N365 for measure- ment.
Disconnect hose RTD and use manual hose mode to finish job until repair can be completed.
Shorted RTD cable in hose or FTS.
Expose each hose RTD connection to check for exposed and shorted RTD wires. Measure hose RTD cable and FTS continuity. See Repair Heated Hose, page 64. Order RTD Test kit 24N365 for measure- ment.
Disconnect hose RTD and use manual hose mode to finish job until repair can be completed.
Shorted A or B Heater RTD
If the error still occurs with the hose FTS unplugged, one of the heater RTDs is bad. Unplug the A or B RTD from the TCM. If unplugging an RTD fixes the T6DT error, replace the RTD.
Sensor Error B · T6DH Hose · Sensor Error TCM

Error Location Type Description Cause Solution
No Temperature Rise A
Bad RTD or bad RTD placement against heater.
Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.
Bad heater rod or loose heater wire.
Confirm resistance of heater. Heater resistance should be 9-12 Ω for 10 kW systems and 6-8 Ω for 15 kW systems. If out of tolerance, check for loose heater rod wire(s). Reconnect wires or replace heater rod if necessary.
Started spraying before heater reached operating temperature.
Wait until operating temperature has been reached before spraying or recirculating.
No Temperature Rise B
Bad RTD or bad RTD placement against heater.
Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.
Bad heater rod or loose heater wire.
Confirm resistance of heater. Heater resistance should be 9-12 Ω for 10 kW systems and 6-8 Ω for 15 kW systems. If out of tolerance, check for loose heater rod wire(s). Reconnect wires or replace heater rod if necessary.
Started spraying before heater reached operating temperature.
Wait until operating temperature has been reached before spraying or recirculating.
No Temperature Rise Hose
Started spraying before heater reached operating temperature.
Wait until operating temperature has been reached before spraying or recirculating.
Loose/bad connection or tripped circuit breaker.
Check wiring for loose connection or tripped circuit breaker.
Low incoming line voltage.
Measure voltage at circuit breaker and ensure voltage is greater than 195 VAC.

Error Location Type Description Cause Solution
Low Voltage CAN Bad 24 VDC power supply.
Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply.
Low Voltage CAN Bad 24 VDC power supply.
Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply.
Loose connection or tripped circuit breaker.
Check wiring for loose connection or tripped circuit breaker.
Low incoming line voltage.
Measure voltage at circuit breaker and ensure voltage is greater than 195 VAC.
Loose connection or tripped circuit breaker.
Check wiring for loose connection or tripped circuit breaker.
Low incoming line voltage.
Measure voltage at circuit breaker and ensure voltage is greater than 195 VAC.
Loose connection or tripped circuit breaker.
Check wiring for loose connection or tripped circuit breaker.
Low incoming line voltage.
Measure voltage at circuit breaker and ensure voltage is greater than 195 VAC.
High Voltage CAN Bad 24 VDC power supply.
Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply.
High Voltage A Incoming line voltage is too high.
Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.
Low Voltage A · Low Voltage B · Low Voltage Hose

Error Location Type Description Cause Solution
High Voltage B Incoming line voltage is too high.
Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.
High Voltage Hose Incoming line voltage is too high.
Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.
High Voltage MCM Incoming line voltage is too high.
Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.
High Voltage CAN Bad 24 VDC power supply.
Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply.
High Voltage A Incoming line voltage is too high.
Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.
High Voltage B Incoming line voltage is too high.
Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.
High Voltage Hose Incoming line voltage is too high.
Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.

Error Location Type Description Cause Solution
Incorrect software version.
Insert a system token into the ADM module and cycle the power. Wait until the upload is complete before removing the token.
MCM does not have line voltage.
If V1CM also exists, see troubleshooting for V1CM. The software version cannot be read if the MCM does not have line voltage.
TCM Fan Error Fan inside TCM is not operating properly.
Check for debris in the TCM fan and clear with forced air if necessary.
A valid configuration file can't be found for the USB.
Inset a system token into the ADM and cycle power. Wait until the lights on the USB port stop flashing before removing token.
USB Download Error Log download failed.
Backup and reformat the USB drive. Retry download.
USB Upload Error Custom language file failed to upload.
Perform normal USB download and use the new disptext.txt file to upload the custom language.
Software Version Error · Configuration Error USB

Before performing any troubleshooting procedures:
Reactor ADM does not turn on.
No power. Turn main power switch ON.
Failed 24 V power supply. Replace power supply.
Failed surge protector. Replace surge protector.
Electric motor does not operate.
Loose connections. Check MCM connection 13.
Tripped circuit breaker (CB02). Reset breaker, see Repair Circuit Breaker Module, page 55. Check 240VAC at output of breaker.
Shorted windings. Replace motor, see Repair Electric Motor, page 54.
Electric motor runs erratically. Failed motor bearing. Replace motor, see Repair Electric Motor, page 54.
Problem Cause Solution

Cooling fans not working.
Loose wire. Check. See Electrical Schematics, page 91.
Fan blade obstructed. Remove obstruction.
Defective fan. Replace. See Replace Motor Fan, page 57.
Pump output low.
Obstructed fluid hose or gun; fluid hose ID too small.
Open, clear; use hose with larger ID.
Worn piston valve or intake valve in displacement pump.
See pump manual.
Pressure setpoint too high. Reduce setpoint and output will increase.
Fluid leak in pump packing nut area.
Worn throat seals. Replace. See pump manual.
No pressure on one side. Fluid leaking from heater inlet rupture disk (372).
Check if heater and PRESSURE RELIEF/SPRAY valve (SA or SB) are plugged. Clear. Replace rupture disk (372) with a new one; do not replace with a pipe plug.
Problem Cause Solution

Before performing any troubleshooting procedures:
Hose heats but heats slower than usual or it does not reach temperature.
Ambient temperature is too cold. Relocate hoses to a warmer area or recirculate heated fluid through the hose.
FTS failed or not installed correctly. Check FTS, see Check RTD Cables and FTS, page 65.
Low supply voltage. Verify line voltage. Low line voltage significantly reduces power available to the hose heat system, affecting longer hose lengths.
Hose does not maintain temperature while spraying.
A and B setpoints too low. Increase A and B setpoints. Hose is designed to maintain temperature, not to increase it.
Ambient temperature is too cold. Increase A and B setpoints to increase fluid temperature and keep it steady.
Flow too high. Use smaller mix chamber. Decrease pressure.
Hose was not fully preheated. Wait for hose to heat to correct temperature before spraying.
Low supply voltage. Verify line voltage. Low line voltage significantly reduces power available to the hose heat system, affecting longer hose lengths.
Problem Cause Solution

Hose temperature exceeds setpoint.
A and/or B heaters are overheating material.
Check primary heaters for either a RTD problem or a failed element attached to RTD, see Electrical Schematics, page 91.
Faulty FTS connections. Verify that all FTS connections are snug and that pins of connectors are clean. Unplug and re-plug RTD wires, cleaning off any debris.
Ambient temperature is too high. Cover hoses or move to a location with a lower ambient temperature.
Missing or damaged insulation around FTS, causing the hose heat to be ON constantly.
Make sure the hose bundle has adequate insulation evenly covering the entire length and connection joints.
Problem Cause Solution

Erratic hose temperature.
Faulty FTS connections. Verify that all FTS connections are snug and that pins of connectors are clean. Unplug and re-plug FTS wires along length of hose, cleaning off any debris.
FTS not installed correctly. FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, see Repair Fluid Temperature Sensor (FTS), page 66.
Missing or damaged insulation around FTS, causing the hose heat to be ON constantly.
Make sure the hose bundle has adequate insulation evenly covering the entire length and connection joints.
Hose does not heat.
FTS failed. Check FTS, see Repair Fluid Temperature Sensor (FTS), page 66.
FTS not installed correctly. FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, see Repair Fluid Temperature Sensor (FTS), page 66.
Loose hose electrical connections. Check connections. Repair as necessary.
Circuit breakers tripped. Reset breakers (CB01 ), see Repair Circuit Breaker Module, page 55.
Hose zone not turned on. Turn on hose heat zone.
A and B temperature setpoints too low.
Check. Increase if necessary.
Problem Cause Solution

Hoses near Reactor are warm, but hoses downstream are cold.
Shorted connection or failed hose heating element.
With power off, check the hose resistance with and without the whip hose attached. With the whip hose attached, the reading should be less than 3 ohm. With- out the whip hose attached, the reading should be OL (open loop). See Check Hose Heat Power Connectors, page 64.
Low hose heat.
A and B temperature setpoints too low.
Increase A and B setpoints. Hose designed to maintain temperature, not increase temperature.
Hose temperature setpoint too low.
Check. Increase if necessary to maintain heat.
Flow too high. Use smaller mix chamber. Decrease pressure.
Low current; FTS not installed. Install FTS, see operation manual.
Hose heat zone not turned on long enough to reach setpoint.
Allow hose to heat up, or preheat fluid.
Loose hose electrical connections. Check connections. Repair as necessary.
Ambient temperature is to low Relocate hoses to a warmer area or increase A and B setpoints.
Problem Cause Solution

Before performing any troubleshooting procedures:
Try the recommended solutions in the order given for each problem, to avoid unnecessary repairs. Also, determine that all circuit breakers, switches, and controls are properly set and wiring is correct before assuming there is a problem.
Primary Heater(s) does not heat.
Heat turned off. Turn on heat zones.
Temperature control alarm. Check ADM for error codes.
Signal failure from RTD. Signal failure from RTD.
Control of primary heat is abnormal; high temperature overshoots (T4DA, T4DB) occurs intermittently.
Dirty RTD connections. Examine RTD cables connected to TCMs. Confirm RTDs are not plugged into opposite heat zone. Unplug and re-plug RTD connectors. Unplug and re-plug RTD connectors. Ensure RTD tip contacts the heater element.
RTD not contacting heater element.
Loosen ferrule nut, push in RTD so tip contacts heater element. Holding RTD tip against heater element, tighten ferrule nut 1/4 turn past tight.
Failed heater element. See Replace Heater Element, page 60.
Signal failure from RTD. See (T6DA, T6DB), Error Codes.
Problems · Problem Cause Solution

Problem Cause Solution Turn Reactor ON. Ensure unit is properly installed.
No module status LEDs are illuminated.
No power to cellular module.
Verify 24V at output of the power supply.
Make sure the M8, 4–pin to M12, 8–pin cable is installed between cellular module and power supply. Still identifying location. Wait a few minutes for the unit to identify the location. Move system to a location with a clear view of the sky.
Has not identified GPS location (green module status LED flashing). Unable to identify location. In a location where GPS lock cannot occur. Buildings and warehouses often prevent GPS locks.
Use extension cable 16X521 and move cellular module to a location with a clear view of the sky. Still establishing cellular connection.
Has not established cellular connection (orange module status LED flashing). Unable to establish cellular connection.
Wait a few minutes for the unit to establish the connection. Move system to a location with cellular service to establish cellular connection.
Use extension cable 16X521 and move cellular module to a location with a clear view of the sky. Cannot view data for my unit(s) on website.
Activate unit. See Registering and Activating the Graco InSite section. Temperature data not displayed on website.
Graco InSite unit has not been activated.
See System troubleshooting section. Hose zone temperature data not displayed on website.
Reactor temperature measurement is not working.
The RTD or thermocouple is not correctly installed on the hose or is broken.
See RTD or Thermocouple repair section.
Pressure data not displayed on website.
Reactor pressure measurement is not working.
See System troubleshooting section.

Follow the Pressure Relief Procedure whenever you see this symbol.
. Ensure gauges drop to 0.
This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing equipment.

The Fusion AP gun is shown.


Pressure Relief Procedure

to park the Component A Pump. The park operation is complete when green dot goes out. Verify the park operation is complete before moving to next step.

Shutdown system to avoid electric shock. All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing equipment.
to deactivate the system.

Proper system setup, startup, and shutdown procedures are critical to electrical equipment reliability. The following procedures ensure steady voltage. Failure to follow these procedures will cause voltage fluctuations that can damage electrical equipment and void the warranty.

to stop the pumps.

To prevent electric shock do not remove any shrouds or open the electrical enclosure door.

Shutdown


Shutdown · Fusion Probler

To flush feed hoses, pumps, and heaters separately from heated hoses, set PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE
. Flush through bleed lines (N).
To avoid fire and explosion:
To flush entire system, circulate through gun fluid manifold (with manifold removed from gun).
To prevent moisture from reacting with isocyanate, always leave the system filled with a moisture-free plasticizer or oil. Do not use water. Never leave the system dry. See Important Isocyanate Information.
Flushing


Repairing this equipment requires access to parts that may cause electric shock or other serious injury if work is not performed properly. Be sure to shut off all power to equipment before repairing.

Proper system setup, startup, and shutdown procedures are critical to electrical equipment reliability. The following procedures ensure steady voltage. Failure to follow these procedures will cause voltage fluctuations that can damage electrical equipment and void the warranty.

The inlet strainers filter out particles that can plug the pump inlet check valves. Inspect the screens daily as part of the startup routine, and clean as required.
Isocyanate can crystallize from moisture contamination or from freezing. If the chemicals used are clean and proper storage, transfer, and operating procedures are followed, there should be minimal contamination of the A-side screen.
Clean the A-side screen only during daily startup. This minimizes moisture contamination by immediately flushing out any isocyanate residue at the start of dispensing operations.
Repair


Check the condition of the ISO pump lubricant daily. Change the lubricant if it becomes a gel, its color darkens, or it becomes diluted with isocyanate.
Gel formation is due to moisture absorption by the pump lubricant. The interval between changes depends on the environment in which the equipment is operating. The pump lubrication system minimizes exposure to moisture, but some contamination is still possible.
Lubricant discoloration is due to continual seepage of small amounts of isocyanate past the pump packings during operation. If the packings are operating properly, lubricant replacement due to discoloration should not be necessary more often than every 3 or 4 weeks.
To change pump lubricant:
Pump Lubrication System Figure 2
Repair


Pump rod and connecting rod move during operation. Moving parts can cause serious injury such as pinching or amputation. Keep hands and fingers away from connecting rod during operation.


Use drop cloth or rags to protect Reactor and surrounding areas from spills.
Steps 9–11 apply to pump A. To disconnect pump B, go to steps 12 and 13.

3 Pump top threads must be nearly flush with bearing face (N).
Steps 1–5 apply to pump B. To reconnect pump A, proceed to step 6.
3 Pump top threads must be nearly flush with bearing face (N).
Steps 12 and 13 apply to pump B.
Steps 6–12 apply to pump A only.
Repair


Do not let tubes kink or buckle.
to stop the pumps.
to park the pumps in the down position.
to deactivate the system.
Repair · Removal


Do not drop gear cluster (104) when removing drive housing (102). Gear cluster may stay engaged in motor front end bell or drive housing.

The A side drive housing includes cycle counter switch (121). If replacing this housing, remove screws (122) and switch. Reinstall screws and switch on new drive housing.

Examine bearing housing (103) and connecting rod (105). If these parts need replacing, first remove the pump (106), see Remove Pump, page 49.
Repair

If bearing housing (103), connecting rod (105), or pump (106) were removed, reassemble rod in housing and install pump, see Install Pump, page 50 .
Drive housing crankshaft must be in line with crankshaft at other end of motor.

Repair · Installation


Be careful not to drop or damage the motor. The motor is heavy and may require two people to lift.

Repair · Removal · Installation

new circuit breaker. Insert wires and tighten down all screws.

Figure 8 Circuit Breakers
a. Refer to Electrical Schematics, page 91, and circuit breaker table.

b. Follow Shutdown instructions. See Shutdown, page 44.
c. Refer to circuit breaker identification table and electrical diagrams in Reactor repair manual.
d. Loosen two screws connecting wires and bus bar to circuit breaker that will be replaced. Disconnect wires.
e. Pull locking tab out 1/4 in. (6mm) and pull circuit breaker away from the din rail. Install
Repair

For Elite models only.


Figure 9 Fluid Inlet Sensor
a. Open wire bundle and remove sensor cable.
b. Cut any wire ties and disconnect from MCM. See Electrical Schematics, page 91.
To prevent damage to cable, route and secure cable in wire bundle with wire ties.
Repair



Shutdown system to avoid electric shock. To avoid burns, do not perform maintenance on the fan until the system has reached ambient temperature.
Ensure fan (32) blows onto motor.
Replace Electrical Enclosure Fan
Repair · Replace Motor Fan


Repair


Repair · Replace Transformer Fan


to stop the pumps.
to park the pumps in the down position. The park operation is complete when green dot goes out. Verify the park operation is complete before moving to next step.
a. A Side: Disconnect A side heater wires, transformer, and transformer fan wires from lower din rail (33).
b. B Side: Disconnect B side heater wires and remove lower din rail (33) from B side heater (5).
to deactivate the system.

To prevent a short circuit or lowering the transformer life, do not splash fluid on transformer. Cover transformer with a plastic sheet or piece of cardboard.
Repair · Replace Heater Element

burnt, ash-like material adhered to element, or sheath shows pitting marks.
The heater outputs its rated wattage at 240 VAC. Low line voltage will reduce power available and the heater will not perform at full capacity.

Repair · Line Voltage

110009, install new switch in same location on housing (201), and secure with screws (213). Reconnect cables.

a. If the resistance is not approximately 0 ohms, the overtemperature switch needs to be replaced. Go to step 5.
b. If the resistance is approximately 0 ohms, inspect cable (46) to ensure it is not cut or open. Reconnect the overtemperature switch (209) and cable (46). Disconnect cable from TCM. Test from pin 1 to 3 and 1 to 4. If resistance is not approximately 0, and switches are 0. Replace cable in place of original cable.
Repair · Repair Overtemperature Switch

a. Apply PTFE tape and thread sealant to male pipe threads and tighten RTD housing (H) into adapter (206).
b. Push in RTD (212) so tip contacts heater element (208).
c. Holding RTD (212) against heater element, tighten ferrule nut (N) 3/4 turn past finger-tight.

Repair · Replace RTD

Refer to the heated hose manual 309572 for hose replacement parts.

Check Hose Heat Power Connectors
Whip hose must be connected.

Repair

Check RTD Cables and FTS

Do not touch outer ring with test probe.

Heated Hose Figure 17
To assist in taking readings, order RTD Test Kit 24N365. Kit includes two cables: one cable with a compatible female M8 connector and another cable with a male M8 connector. Both cables have stripped wire at the other end for easy test probe access.

3 to 1 / brown to blue approximately 1090 ohms
3 to 4 / blue to black approximately 1090 ohms
1 to 4 / brown to black 0.2 - 0.4 ohms
Repair

The Fluid Temperature Sensor (FTS) is supplied with the system. Install FTS between main hose and whip hose. See Heated Hose manual 309572 for instructions.

a. Disconnect air hoses (C,L) and electrical connectors (D).
b. Disconnect FTS from whip hose (W) and fluid hoses (A, B).
c. Remove ground wire (K) from ground screw on underside of FTS.
d. Remove FTS probe (H) from component A (ISO) side of hose.
Repair · Installation · Test/Removal

indicator on the circuit breaker GREEN. Use an ohmmeter to test for continuity between two transformer wires in terminal blocks TB17 and TB18; there should be continuity.
See Electrical Schematics, page 91.
a. See Shutdown, page 44.
c. Close the circuit breaker CB01.
b. Shut off CB05.
c. Use an ohmmeter to test for continuity between terminals 2 and 4 of CB05. If there is no continuity, check transformer.
a. See Shutdown, page 44.
b. Remove lower shroud.
d. Apply incoming power to system.
c. Locate the two smaller (10 AWG) wires, labeled 1 and 2, coming out of transformer. Trace these wires back to terminal blocks TB15 and TB16.
e. To verify voltage on the secondary leads of the transformer, measure between the terminals terminals 3 and 4 on TB17 and TB18. Verify voltage is approximately 90 VAC for 240 VAC input.
d. Use an ohmmeter to test for continuity between two wires; there should be continuity.
f. See the Diagnostic Run Screen on the ADM. The Diagnostic Run Screen displays the incoming (90 Vac) to the TCM “Hose Voltage”. The diagnostic screen will show if the circuit breaker has been tripped for the incoming power to the TCM.
See Electrical Schematics, page 91.
a. Disconnect 7 pin green connector from TCM.

b. Use an ohmmeter to test for continuity between terminals 6 and 7 on the TCM 7 pin green connector. There should be continuity. If there is no continuity, check transformer.
c. Reconnect 7 pin green connector to TCM
a. Remove lower shroud.
b. Locate the two larger (6 AWG) wires, labeled 3 and 4, coming out of transformer. Trace these wires back to TB17 and TB18. Open circuit breaker CB01 to turn the color
Repair · Transformer Primary Check · Transformer Secondary Check


Repair · Replace Transformer


Wire on both the circuit breaker and power supply are interchangeable.

Replace Temperature Control Module (TCM)


Figure 25 Replace TCM
Figure 24 Replace MCM

Repair kit GCA modules are shipped pre-programmed and software loading is not necessary. If software version upgrade is necessary, follow the procedure in the manual provided.
Repair


Parts


1 Apply anaerobic polyacrylate pipe sealant to all non-swiveling pipe threads.
2 Apply grease to tube fitting threads. Torque to 43 ft-lbs (58 N•m).
3 Safety and warning labels are from label sheet (68).
Parts


4 16X531 BRACKET, tsl, bottle 1
24U843 HEATER, 10kw, 2 zone, RTD; see Fluid Heater, page 80
24U842 HEATER, 7.5kw, 1 zone, RTD; see Fluid Heater, page 80
6 24U704 MANIFOLD, fluid; see Fluid Manifold, page 82
8 24R684 COVER, transformer 1
9+ 261821 CONNECTOR, wire, 6awg 1
10 24U841 COVER, heater 1
11 16W765 COVER, motor 1
12 16W764 COVER, heater, rear 1
24U837 TUBE, b-side, inlet 13
24U839 TUBE, b-side, outlet 14
17 15K742 TRANSFORMER, 4090va, 230/90 1
18 15B456 GASKET, manifold 1
19 125643 FITTING, elbow, 3/8 npt x #8 jic
20 119865 SCREW, mch, hex serrated; 3/8 in. x 1/4–20
Parts

Quantity Ref Part Description
272010 272011 272012 272110 272111 272112
21 118444 SCREW, mch, slot hex wash hd; 1/2 in. x #10–24
12
22 117683 SCREW, mch, phil pan hd; 1.5 in. x #6–32
8
23 113796 SCREW, flanged, hex hd; 3/4 in. x 1/4–20 11 13 13 11 13 13
24 112731 NUT, hex, flanged 6
25 111800 SCREW, cap, hex hd; 7/32 in. x 5/16–18 4
26 111218 CAP, tube, square 2
27 110996 NUT, hex, flange head 8
28 104859 SCREW, tapping pnhd; 5/16 in. x #10–16 2
29 103181 WASHER, lock ext 4
30 100020 WASHER, lock 2
31 115836 GUARD, finger 1
32 24U847 FAN, cooling, 120mm, 24vdc 2
33 24R685 ENCLOSURE, lower, dinrail; includes 33a-33d
1
33a 24U849 KIT, module, din rail, heater; see Heater and Transformer Terminal Block Module, page 87
1
33b 16W667 INSULATOR, FOAM 1
33c - - - COVER, bottom, dinrail 1
33d 113505 NUT, keps, hex hd 1
34 151395 WASHER, flat 4
35 120685 GROMMET 2
36 114269 GROMMET, rubber 1
37 125625 TIE, cable, fir tree 5 6 6 5 6 6
38 127277 BOLT, carriage, 1/2-13 x 3.5 l 4
39 127278 NUT, keps, hex 4
40 127282 GROMMET, rubber 4
41 16X095 CONNECTOR, power, male, 4 pin
1
42★ 125871 TIE, cable, 7.5 in. 25
43★ 24K207 KIT, fts, rtd, single hose 1
Parts


45★ 106569 TAPE, electrical 1
47 104765 PLUG, pipe headless 2 1
48 16V268 COVER, top, dinrail 1
49 15Y118 LABEL, made in the USA 1
24V150 PROPORTIONER, module, E-30; see Proportioner Module, page 78
24V151 PROPORTIONER, module, E-XP2; see Proportioner Module, page 78
24U321 KIT, asm, pair, elite, reactor; see Fluid Inlet Kits, page 89
24U320 KIT, assembly, pair, std, reactor; see Fluid Inlet Kits, page 89
53 24T050 CABLE, m8 4p f to m12 8p m 1.5m 1 1 1
54 16W130 CABLE, m12 5p, fem - male, 2.0m
55 24U845 TUBE, pressure relief 2
56 191892 FITTING, elbow, street, 90 deg; 1/8 npt 2
57 116746 FITTING, barbed, plated; 1/8–27 npt x 1/4 in. hose I.D.
Parts


60 15G349 COVER, drive, plastic 2
61 16W766 COVER, control, box 1
62 16W596 LATCH, door 2
64★ 206995 FLUID, tsl, 1 qt. 1
65★ 206994 FLUID, tsl 8 oz bottle 1
67★ 114225 TRIM, edge protection; 1.6 ft (0.48 m) 1
68 16X250 LABEL, identification 1
70 127296 SCREW, mchn, pnh, w/ext tooth wash; M4 x 0.7
71 16X129 SCREW, mach, phillips, tooth wash; 5/16 x 8–32
79+★ 261843 FLUID, oxide inhibitor 1
81 16V806 BRACKET, wall, mount 2
83★ 24K409 BAR, 55 gal chem. measure; A side
84★ 24K411 BAR, 55 gal chem. measure. B side
85 127276 BOLT, carriage, 1/2-13 x 2.5 l 2
88 24U854 MODULE, ADM 1
Parts


90 16W213 LABEL, branding, reactor 2
91 115942 NUT, hex, flange head 4
94 127377 TIE, cable, 6 in. 1 1 1
99* 17C258 ENCLOSURE, cover 1
100*▲ 189930 LABEL, caution 1
101*▲ 172953 LABEL, ground 1
102* 17D955 BRACKET, mounting 1
103* 113161 SCREW, flange, hex hd 2
▲Replacement Warning labels, signs, tags, and
See Electrical Schematics, page 91. + Part applies to Series A only.
cards are available at no cost.
★Not shown.
* Part applies to Series B only.
Parts included in Graco Insite Kit 24T280.
Parts


2 Lubricate threads with ISO oil or grease. Assemble pump cylinders flush to one full thread under-flush of housing surface.
3 Apply grease to all gear teeth proportionally, motor pinion and drive housing.
5 Crankshaft must be in line with crankshaft at other end of motor.
Parts


101 24U050 MOTOR, brushless, double ended, 2 HP 1 1
112 15C753 SCREW, machine, hex wash hd; 1.25 in. x 5/16–18 10 10
113 114666 SCREW, cap, socket head; 2.25 x 3/8–16 8 8
122 127301 SCREW, hexhead, thread cut, 4-40 x 0.375 2 2
▲Replacement Warning labels, signs, tags, and
Gear Repair Kit includes washers (107) and (108).
cards are available at no cost.
★See pump repair manual 309577 for repair kits.
Drive Housing Repair Kit includes housing (1), screws (5), and washer (1) to replace one end.
Spring (110) included in Connecting Rod Kit 241279.
Parts

24U843 — 10kW, 2–zone 24U842 — 7.5 kW, 1–zone

5 Apply pipe sealant and PTFE tape to all non-swiveling threads and threads without o-rings.
6 Apply lithium grease lubricant to o-rings before assembling in block (1).
7 Remove tape from probe tip and Orientate sensor as shown. Insert probe until it bottoms on heating element. Tighten ferrule on sensor probe one turn past finger tight or 16 ft-lbs (21.6 N•m).
Parts

Ref Part Description 24U843 24U842 15J090 HEATER, machined, 1 zone 1 201
15K825 HEATER, machined, dual zone 1
203 15H305 FITTING, plug, hollow, hex, 1-3/16 sae 4 5
204 121309 FITTING, adapter, sae-orb x jic 4 2
205 15H304 FITTING, plug 9/16 sae 2 3
206 15H306 ADAPTER, 9/16 x 1/8 2 1
207 120336 O-RING, packing 2 1
208 16A110 HEATER, immersion, 2550W, 230V 4 3
209 15B137 SWITCH, over temperature 1 1
210 15B135 MIXER, immersion heater 4 3
211* - - - FITTING, compression 2 1
213 124131 SCREW, machine, pnhd; 5/16 in. x #6–32 2 2
214 15M178 HOUSING, rupture disc 2 1
* Included in 24L973 Heater RTD Repair Kit.
Parts

24U844

4 Apply PTFE tape and thread sealant to gauge threads.
1 Torque to 355–395 in.-lbs (40–44.6 N●m)
2 Apply sealant (113500) to threads.
5 Apply grease on valve.
3 Valve must be closed with handle position as shown on drawing.
** Apply PTFE tape or thread sealant to tapered threads.
Parts

Ref Part Description Qty
Ref Part Description Qty
401 255228 MANIFOLD, fluid 1
413 100840 FITTING, elbow, street 2
402★ 247824 KIT, valve, cartridge, drain 2
402a★158674 O-RING, BUNA-N 1
415▲ 189285 LABEL, caution 1
402b★247779 SEAL, seat, valve 1
416 150829 SPRING, compression 2
403 102814 GAUGE, press, fluid 2
419 117557 NIPPLE, #10 JIC x 1/2 NPT
▲ Replacement Warning labels, signs, tags, and cards are available at no cost.
405 15M669 SENSOR, pressure, fluid outlet
★ Included in the following complete valve kits: ISO Valve Kit (left/red) handle 255149. Resin Valve Kit (right/blue handle) 255150. Valve Set Kit (both handles and grease gun) 255148.
406 247788 HANDLE, red 1
407 247789 HANDLE, blue 1
408 112309 NUT, hex, jam 2
411 117556 NIPPLE, #8 JIC x 1/2 NPT 1
412 121312 FITTING, elbow, 3/4 SAE x 1/2 JIC
Parts


Parts

Ref Part Description Qty 451 24U087 ENCLOSURE 1 453 24U855 MODULE, TCM 1 454 24U848 FAN, cooling, 80 mm, 24VDC 1 455 24R736 SWITCH, disconnect, door mounted 1 457 117666 TERMINAL, ground 1 458 120859 NUT, strain relief, M40 thread 1 459 120858 BUSHING, strain relief, M40 thread 1 460 123967 KNOB, operator disconnect 1 461 115942 NUT, hex, flange head 5 462 103181 WASHER, lock external 2 463 124131 SCREW, machine, pan head; 5/16 in. x #6–32 2 464 194337 WIRE, grounding, door 1 466 113505 NUT, keps, hex head 6
Ref Part Description Qty 468 111218 CAP, tube, square 2 469 114269 GROMMET, rubber 1 470 127282 GROMMET, rubber 2 471 127278 NUT, keps, hex 4 472 16W925 GASKET, enclosure, foam 2 473 16W926 GASKET, enclosure, foam 2 474 24R735 CABLE, CAN power, M12 female, pigtail 1 475 127068 CABLE, CAN, female/female 1.0 meter 2 476 24U850 MODULE, breaker 1 477 127290 CABLE, 4-pin, male/female, 1.3 meter, molded (hose RTD) 1 478▲ 16X050 LABEL, safety; enclosure 1 479▲ 16X049 LABEL, safety; multi 1
▲Replacement Warning labels, signs, tags, and
cards are available at no cost.
See Electrical Schematics, page 91.
Parts

24U850, System DIN Rail and Harness Module Kit
See Electrical Schematics, page 91.

1 Torque to 6–8 in.-lbs (0.7–1 N●m)
2 Torque to 28–33 in.-lbs (3–3.8 N●m)
3 Torque to 23–26 in.-lbs (2.6–3 N●m)
Parts

Ref Part Description Qty 501 16U529 HARNESS, breaker module 1 502 16V515 HARNESS, hose out 1 503 16U522 MODULE, din rail, term blk, power sup; see System Circuit Breaker Module, page 88 1
Ref Part Description Qty 504 16U526 MODULE, din rail, circuit breakers; see Power Supply and Terminal Block Module, page 88 1 505 16U530 MODULE, sys surge protector 1
24U849

Ref Part Description Qty 511 24T315 RAIL, DIN; 35 mm x 7.5 mm x 7 in.
Ref Part Description Qty 515 120570 BLOCK, terminal 6
516 24R758 BLOCK, terminal, UT-2.5, red
512 126811 BLOCK, clamp, end 2
513 126383 COVER, end 1
517 24R759 BLOCK, terminal, UT-2.5, black
514 126382 BLOCK, terminal 2
Parts


Ref Part Description Qty 521 514014 RAIL, DIN; 35 mm x 7.5 mm x 8.625 in. 1
Ref Part Description Qty 524 17A314 CIRCUIT, breaker, 2P, 20A, UL489 1
522 120838 TERMINAL, end stop 2
525 17A317 CIRCUIT, breaker, 2P, 40A, UL489 3
523 17A319 CIRCUIT, breaker, 1 pole, 50A, C Curve

Ref Part Description Qty 531 514014 RAIL, DIN; 35 mm x 7.5 mm x 8.625 in.
Ref Part Description Qty 534 24R723 BLOCK, terminal, quad M4, ABB
532 120838 TERMINAL, end stop 3
533 24R722 BLOCK, terminal PE, quad, ABB
536 24R724 BLOCK, terminal, UT35 6
Parts

24U320, Standard 24U321, Elite

1 Apply sealant to all tapered pipe threads. Apply sealant to female threads. Apply to at least the first four threads and approximately 1/4 turn wide.
2 Apply thermal paste to the stem of dial before assembling into housing.
Parts

Quantity Ref Part Description
601 160327 FITTING, union adapter, 90° 2 2
602 118459 FITTING, union, swivel, 3/4 in. 2 2
603 247503 MANIFOLD, strainer, inlet 2 2
604 24U852 THERMOMETER, dial 2 2
605 24U853 GAUGE, press, fluid 2 2
606★ - - - FILTER, replacement 2 2
607★ C20203 PACKING, o-ring, 1.17, fluoroelastomer 2 2
608 16V879 CAP, filter 2 2
609 555808 PLUG, 1/4mp w/ hex hd 2 2
610 15D757 HOUSING, thermometer, viscon hp 2 2
613 109077 VALVE, ball 3/4 npt 1 2
614 C20487 FITTING, nipple, hex 2
614 624545 FITTING, tee 3/4m run x 1/4f branc 2
615 24U851 TRANSDUCER, pressure, temperature (includes foam) 2
* Optional 80 mesh filter 255082 (2 pack)
★Included in 24V020 Inlet Filter and Seal Kit, 20
mesh (2 pack).
Included in 247503 Manifold Repair Kit.
Parts


Electrical Schematics



Electrical Schematics


2 Heated hose wire termination enclosure (series B only).
Electrical Schematics

Reactor 2 Repair Spare Parts Reference
Ref Part Description Part of Assembly
106, 115 15C852 E-30 Pump Repair Kit Pump
106, 115 15C851 E-XP2 Pump Repair Kit Pump
106, 115 246963 E-XP2 Wet Cup Repair Kit Pump
106, 115 246964 E-30 Wet Cup Repair Kit Pump
606, 607 24V020 Y-Strainer Filter and Gasket Kit (pack of two each)
402 247824 Drain Valve Cartridge Fluid Manifold
403 102814 Fluid Pressure Gauge Fluid Manifold
405 15M669 Pressure Sensor Fluid Manifold
211, 212 24L973 RTD Repair Kit Heater
-- 24K207 Hose FTS Hose
-- 24N450 RTD Cable (50 ft. replacement) Hose
-- 24N365 RTD Cable Test Kit (To assist measureing RTDs and RTD cable resistances)
Y-Strainer · Hose

Use these charts to help identify the proportioner that will work most efficiently with each mix chamber. Flow rates are based on a material viscosity of 60 cps.
AR5252
AR6060
PRESSURE
AR7070
E-30
500 (34) 0 5 (2.3)
40 (18.1) 10 (4.5)
15 (6.8)
20 (9.1)
25 (11.3)
30 (13.6)
35 (15.9)

Table 1 Fusion Air Purge, Round Pattern
E-XP2
PRESSURE
AR2929
AR4242
0 0.5 (1.9)
1.5 (5.7) 1.0 (3.8)
2.0 (7.6)
FLOW gal./min (l/min)
Table 2 Fusion Air Purge, Flat Pattern
3500 (241, 24.1)
3000 (207, 20.7)
2500 (174, 17.4)
AF2020 (FTXX24 TIP)
PRESSURE
2000 (138, 13.8)
E-XP2
1500 (103, 10.3)
1000 (69, 6.9)
500 (35, 3.5)
0 0.5 (1.9)
1.5 (5.7) 1.0 (3.8)
2.0 (7.6)
FLOW gal./min (l/min)

Table 3 Fusion Mechanical Purge, Round Pattern
3500 (241, 24.1)
3000 (207, 20.7)
XR2323 (RTM040)
2500 (174, 17.4)
PRESSURE
2000 (138, 13.8)
1500 (103, 10.3)
1000 (69, 6.9)
500 (35, 3.5)
0 0.5 (1.9)
1.5 (5.7) 1 (3.8)
2.0 (7.6)
FLOW gal./min (l/min)
Table 4 Fusion Mechanical Purge, Flat Pattern
3500 (241, 24.1)
XF2323 (FTM424)
3000 (207, 20.7)
2500 (174, 17.4)
XF2929 (FTM424)
MF1818 (FTM424)
2000 (138, 13.8)
E-XP2
XF1818 (FTM424)
MF5757 (FTM638)
MF3535 (FTM638)
1500 (103, 10.3)
XF3535 (FTM638)
1000 (69, 6.9)
500 (35, 3.5)
0 0.4 (1.5)
0.8 (3.0) 0.2 (0.7)
0.6 (2.3)
1.8 (6.8) 1 (3.8)
1.4 (5.3) 1.2 (4.5)
1.6 (6.0)
2.0 (7.6)
FLOW gal./min (l/min)
Performance Charts · psi (bar) · psi (bar)


E-30 190°F 88°C E-XP2 190°F 88°C Maximum Flow Rate
E-30 150°F 66°C E-XP2 150°F 66°C Maximum Inlet Fluid Pressure
Output per Cycle ISO and RES E-30 0.0272 gal. 0.1034 liter
Operating Ambient Temperature Range Temperature 20° to 120°F -7° to 49°C Line Voltage Requirement
Nominal 200–240 VAC, 1 Phase, 50/60 Hz 195–265 VAC
Nominal 200–240 VAC, 3 phase, DELTA, 50/60 Hz 195–265 VAC
Nominal 350–415 VAC, 3 phase, WYE, 50/60 Hz 340–455 VAC
Heater Power (at 230 VAC rated voltage) E-30 10 kW 10,200 Watts
Technical Specifications

Sound Pressure Sound Pressure measured per ISO-9614–2. E-30 Measured from 3.1 ft (1 m), at 1000 psi (7 MPa, 70 bar), 3 gpm (11.4 lpm)
87.3 dBA
E-XP2 Measured from 3.1 ft (1 m), at 3000 psi (21 MPa, 207 bar), 1 gpm (3.8 lpm)
79.6 dBA
Sound Power E-30 Measured from 3.1 ft (1 m), at 1000 psi (7 MPa, 70 bar), 3 gpm (11.4 lpm)
93.7 dBA
E-XP2 Measured from 3.1 ft (1 m), at 3000 psi (21 MPa, 207 bar), 1 gpm (3.8 lpm)
86.6 dBA
Component A ISO) and Component B (RES)
3/4 NPT(f) with 3/4 NPSM(f) union
Component A (ISO) #8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter
Component B (RES) #10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter
Size 1/4 NPSM(m) Maximum Pressure 250 psi 1.75 MPa, 17.5 bar
Width 26.3 in. 668 mm
Height 63 in. 1600 mm
Depth 15 in. 381 mm
E-30, 10 kW 315 lb 143 kg
E-30, 15 kW 350 lb 159 kg
E-30, 10 kW Elite 320 lb 145 kg
E-30, 15 kW Elite 355 lb 161 kg
E-XP2 345 lb 156 kg
E-XP Elite 350 lb 159 kg
Material Aluminum, stainless steel, zinc plated carbon steel, brass, carbide, chrome, chemically resistant o-rings, PTFE, ultra-high


Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
Graco Part Number Description Warranty Period
24U050 24U051 Electric Motor 36 Months or 3 Million Cycles
24U831 Motor Control Module 36 Months or 3 Million Cycles
24U832 Motor Control Module 36 Months or 3 Million Cycles
24U855 Heater Control Module 36 Months or 3 Million Cycles
24U854 Advanced Display Module 36 Months or 3 Million Cycles
All other Reactor 2 parts 12 Months
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty hereunder must be brought within the latter of two (2) years of the date of sale, or one (1) year the warranty period expires.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

For the latest information about Graco products, visit www.graco.com
To place an order, contact your Graco Distributor or call to identify the nearest distributor.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
Original Instructions. This manual contains English. MM 333024
Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Revision F, July 2015
Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| DE0X | Cycle Switch Error | Check wiring between cycle switch and MCM. | p.17 |
| F9DX | High Pressure/Flow Cutback | Reference the pressure flow curves and select a tip size that is the correct size for the set pressure. | p.18 |
| H2MA | Low Frequency A | Ensure line frequency of incoming power is between 45 and 65 Hz. | p.18 |
| H2MB | Low Frequency B | Ensure line frequency of incoming power is between 45 and 65 Hz. | p.18 |
| H2MH | Low Frequency Hose | Ensure line frequency of incoming power is between 45 and 65 Hz. | p.18 |
| H3MA | High Frequency A | Ensure line frequency of incoming power is between 45 and 65 Hz. | p.18 |
| H3MB | High Frequency B | Ensure line frequency of incoming power is between 45 and 65 Hz. | p.18 |
| H3MH | High Frequency Hose | Ensure line frequency of incoming power is between 45 and 65 Hz. | p.18 |
| K8NM | Locked Rotor Motor | Remove pump gear housings from motor and check that motor shaft rotates freely in direction indicated on motor housing. | p.18 |
| L1AX | Low Chemical Level A | Refill material and update drum level on ADM Maintenance screen. Alarm can be disabled on the System Setup screen. | p.19 |
| L1BX | Low Chemical Level B | Refill material and update drum level on ADM Maintenance screen. Alarm can be disabled on the System Setup screen. | p.19 |
| P0AX | Pressure Imbalance A High | Ensure material flow is equally restricted on both material lines. | p.19 |
| P0BX | Pressure Imbalance B High | Ensure material flow is equally restricted on both material lines. | p.20 |
| P1FA | Low Inlet Pressure A | Ensure that inlet pressure to the pump is sufficient. | p.20 |
| P1FB | Low Inlet Pressure B | Ensure that inlet pressure to the pump is sufficient. | p.20 |
| P2FA | Low Inlet Pressure A | Ensure that inlet pressure to the pump is sufficient. | p.20 |
| P2FB | Low Inlet Pressure B | Ensure that inlet pressure to the pump is sufficient. | p.21 |
| P4AX | High Pressure A | Pressure in the hose and pumps will increase as the system heats up. Turn on heat and allow all zones to reach the temperature setpoint before turning on the pumps. | p.21 |
| P4BX | High Pressure B | Pressure in the hose and pumps will increase as the system heats up. Turn on heat and allow all zones to reach the temperature setpoint before turning on the pumps. | p.21 |
| P6AX | Pressure Sensor Error A | Check to ensure the pressure transducer is properly installed and all wires are properly connected. | p.22 |
| P6BX | Pressure Sensor Error B | Check to ensure the pressure transducer is properly installed and all wires are properly connected. | p.22 |
| P6FA | Pressure Sensor Error Inlet A | If inlet sensors are not installed, inlet sensors should be disabled on the System Setup screen. | p.22 |
| P6FB | Pressure Sensor Error Inlet B | If inlet sensors are not installed, inlet sensors should be disabled on the System Setup screen. | p.23 |
| P7AX | Pressure Imbalance A High | Ensure material flow is equally restricted on both material lines. | p.23 |
| P7BX | Pressure Imbalance B High | Ensure material flow is equally restricted on both material lines. | p.24 |
| T2DA | Low Temperature A | Use a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint. | p.24 |
| T2DB | Low Temperature B | Use a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint. | p.25 |
| T2DH | Low Temperature Hose | Use a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint. | p.25 |
| T2FA | Low Temperature Inlet A | Recirculate fluid through heaters until inlet fluid temperature is above defined error level. | p.25 |
| T2FB | Low Temperature Inlet B | Recirculate fluid through heaters until inlet fluid temperature is above defined error level. | p.25 |
| T3CH | Hose Cutback | Hose setpoint higher than A and B setpoints. Decrease hose setpoint. | p.26 |
| T3CT | TCM Cutback | Ensure ambient temperature is below 120°F(48°C) before using the system. | p.26 |
| T3NM | Motor Temperature Cutback | The system is running at a lower setpoint to preserve motor life. Run the system at a lower duty cycle or with a smaller mix chamber. | p.26 |
| T3CM | MCM Temperature Cutback | Ensure ambient temperature is below 120°F(48°C). Verify that all fans are working. | p.26 |
| T4CM | High Temperature MCM | Ensure ambient temperature is below 120°F(48°C) before using the system. | p.26 |
| T4CT | High Temperature TCM | Ensure ambient temperature is below 120°F(48°C) before using the system. | p.27 |
| T4DA | High Temperature A | Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD. | p.27 |
| T4DB | High Temperature B | Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD. | p.27 |
| T4DH | High Temperature Hose | Shade exposed hose from hot sun or expose FTS to same environment when at rest. Uncoil entire hose before heating to avoid self-heating. | p.28 |
| T4EA | High Temperature Switch A | Heater was delivered too much power, causing the overtemperature switch to open. RTD is not reading properly. After the heater cools down, replace RTD. Switch closes and the error can be cleared when the heater temperature falls below 190°F (87°C). | p.28 |
| T4EB | High Temperature Switch B | Heater was delivered too much power, causing the overtemperature switch to open. RTD is not reading properly. After the heater cools down, replace RTD. Switch closes and the error can be cleared when the heater temperature falls below 190°F (87°C). | p.29 |
| T4NM | High Temperature Motor | Check to see that the motor fan is moving. Measure voltage to fan. There should be 24 VDC. If no voltage is measured, check fan wiring. If the fan has voltage but is not moving, replace fan. If necessary use an air hose to blow out around the fan housings and remove any built-up debris. | p.29 |
| T6DA | Sensor Error A | Check all wiring and connection to RTD. | p.29 |
| T6DB | Sensor Error B | Check all wiring and connection to RTD. | p.30 |
| T6DH | Sensor Error Hose | Expose each hose RTD connection to check and retighten any loose con- nector. Measure hose RTD cable and FTS continuity. See Repair Heated Hose, page 64. Order RTD Test kit 24N365 for measure- ment. Disconnect hose RTD and use manual hose mode to finish job until repair can be completed. | p.30 |
| T6DT | Sensor Error TCM | Expose each hose RTD connection to check for exposed and shorted RTD wires. Measure hose RTD cable and FTS continuity. See Repair Heated Hose, page 64. Order RTD Test kit 24N365 for measure- ment. Disconnect hose RTD and use manual hose mode to finish job until repair can be completed. | p.30 |
| T8DA | No Temperature Rise A | Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD. | p.31 |
| T8DB | No Temperature Rise B | Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD. | p.31 |
| T8DH | No Temperature Rise Hose | Wait until operating temperature has been reached before spraying or recirculating. | p.31 |
| V1CM | Low Voltage MCM | Check wiring for loose connection or tripped circuit breaker. | p.31 |
| V1IT | Low Voltage CAN | Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply. | p.32 |
| V2IT | Low Voltage CAN | Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply. | p.32 |
| V2MA | Low Voltage A | Check wiring for loose connection or tripped circuit breaker. | p.32 |
| V2MB | Low Voltage B | Check wiring for loose connection or tripped circuit breaker. | p.32 |
| V2MH | Low Voltage Hose | Check wiring for loose connection or tripped circuit breaker. | p.32 |
| V3IT | High Voltage CAN | Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply. | p.32 |
| V3MA | High Voltage A | Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. | p.32 |
| V3MB | High Voltage B | Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. | p.33 |
| V3MH | High Voltage Hose | Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. | p.33 |
| V4CM | High Voltage MCM | Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. | p.33 |
| V4IT | High Voltage CAN | Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply. | p.33 |
| V4MA | High Voltage A | Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. | p.33 |
| V4MB | High Voltage B | Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. | p.33 |
| V4MH | High Voltage Hose | Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. | p.33 |
| WBC0 | Software Version Error | Insert a system token into the ADM module and cycle the power. Wait until the upload is complete before removing the token. | p.34 |
| WMI0 | TCM Fan Error | Check for debris in the TCM fan and clear with forced air if necessary. | p.34 |
| TB18 | Verify voltage is approximately 90 | p.67 |
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Reactor ADM does not turn on. | No power. | Turn main power switch ON. | p.35 |
| Reactor ADM does not turn on. | Failed 24 V power supply. | Replace power supply. | p.35 |
| Reactor ADM does not turn on. | Failed surge protector. | Replace surge protector. | p.35 |
| Electric motor does not operate. | Loose connections. | Check MCM connection 13. | p.35 |
| Electric motor does not operate. | Tripped circuit breaker (CB02). | Reset breaker, see Repair Circuit Breaker Module, page 55. Check 240VAC at output of breaker. | p.35 |
| Electric motor does not operate. | Shorted windings. | Replace motor, see Repair Electric Motor, page 54. | p.35 |
| Electric motor runs erratically. | Failed motor bearing. | Replace motor, see Repair Electric Motor, page 54. | p.35 |
| Cooling fans not working. | Loose wire. | Check. See Electrical Schematics, page 91. | p.36 |
| Cooling fans not working. | Fan blade obstructed. | Remove obstruction. | p.36 |
| Cooling fans not working. | Defective fan. | Replace. See Replace Motor Fan, page 57. | p.36 |
| Pump output low. | Obstructed fluid hose or gun; fluid hose ID too small. | Open, clear; use hose with larger ID. | p.36 |
| Pump output low. | Worn piston valve or intake valve in displacement pump. | See pump manual. | p.36 |
| Pump output low. | Pressure setpoint too high. | Reduce setpoint and output will increase. | p.36 |
| Fluid leak in pump packing nut area. | Worn throat seals. | Replace. See pump manual. | p.36 |
| No pressure on one side. | Fluid leaking from heater inlet rupture disk (372). | Check if heater and PRESSURE RELIEF/SPRAY valve (SA or SB) are plugged. Clear. Replace rupture disk (372) with a new one; do not replace with a pipe plug. | p.36 |
| Hose heats but heats slower than usual or it does not reach temperature. | Ambient temperature is too cold. | Relocate hoses to a warmer area or recirculate heated fluid through the hose. | p.37 |
| Hose heats but heats slower than usual or it does not reach temperature. | FTS failed or not installed correctly. | Check FTS, see Check RTD Cables and FTS, page 65. | p.37 |
| Hose heats but heats slower than usual or it does not reach temperature. | Low supply voltage. | Verify line voltage. Low line voltage significantly reduces power available to the hose heat system, affecting longer hose lengths. | p.37 |
| Hose does not maintain temperature while spraying. | A and B setpoints too low. | Increase A and B setpoints. Hose is designed to maintain temperature, not to increase it. | p.37 |
| Hose does not maintain temperature while spraying. | Ambient temperature is too cold. | Increase A and B setpoints to increase fluid temperature and keep it steady. | p.37 |
| Hose does not maintain temperature while spraying. | Flow too high. | Use smaller mix chamber. Decrease pressure. | p.37 |
| Hose does not maintain temperature while spraying. | Hose was not fully preheated. | Wait for hose to heat to correct temperature before spraying. | p.37 |
| Hose does not maintain temperature while spraying. | Low supply voltage. | Verify line voltage. Low line voltage significantly reduces power available to the hose heat system, affecting longer hose lengths. | p.37 |
| Hose temperature exceeds setpoint. | A and/or B heaters are overheating material. | Check primary heaters for either a RTD problem or a failed element attached to RTD, see Electrical Schematics, page 91. | p.38 |
| Hose temperature exceeds setpoint. | Faulty FTS connections. | Verify that all FTS connections are snug and that pins of connectors are clean. Unplug and re-plug RTD wires, cleaning off any debris. | p.38 |
| Hose temperature exceeds setpoint. | Ambient temperature is too high. | Cover hoses or move to a location with a lower ambient temperature. | p.38 |
| Hose temperature exceeds setpoint. | Missing or damaged insulation around FTS, causing the hose heat to be ON constantly. | Make sure the hose bundle has adequate insulation evenly covering the entire length and connection joints. | p.38 |
| Erratic hose temperature. | Faulty FTS connections. | Verify that all FTS connections are snug and that pins of connectors are clean. Unplug and re-plug FTS wires along length of hose, cleaning off any debris. | p.39 |
| Erratic hose temperature. | FTS not installed correctly. | FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, see Repair Fluid Temperature Sensor (FTS), page 66. | p.39 |
| Erratic hose temperature. | Missing or damaged insulation around FTS, causing the hose heat to be ON constantly. | Make sure the hose bundle has adequate insulation evenly covering the entire length and connection joints. | p.39 |
| Hose does not heat. | FTS failed. | Check FTS, see Repair Fluid Temperature Sensor (FTS), page 66. | p.39 |
| Hose does not heat. | FTS not installed correctly. | FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, see Repair Fluid Temperature Sensor (FTS), page 66. | p.39 |
| Hose does not heat. | Loose hose electrical connections. | Check connections. Repair as necessary. | p.39 |
| Hose does not heat. | Circuit breakers tripped. | Reset breakers (CB01 ), see Repair Circuit Breaker Module, page 55. | p.39 |
| Hose does not heat. | Hose zone not turned on. | Turn on hose heat zone. | p.39 |
| Hose does not heat. | A and B temperature setpoints too low. | Check. Increase if necessary. | p.39 |
| Hoses near Reactor are warm, but hoses downstream are cold. | Shorted connection or failed hose heating element. | With power off, check the hose resistance with and without the whip hose attached. With the whip hose attached, the reading should be less than 3 ohm. With- out the whip hose attached, the reading should be OL (open loop). See Check Hose Heat Power Connectors, page 64. | p.40 |
| Low hose heat. | A and B temperature setpoints too low. | Increase A and B setpoints. Hose designed to maintain temperature, not increase temperature. | p.40 |
| Low hose heat. | Hose temperature setpoint too low. | Check. Increase if necessary to maintain heat. | p.40 |
| Low hose heat. | Flow too high. | Use smaller mix chamber. Decrease pressure. | p.40 |
| Low hose heat. | Low current; FTS not installed. | Install FTS, see operation manual. | p.40 |
| Low hose heat. | Hose heat zone not turned on long enough to reach setpoint. | Allow hose to heat up, or preheat fluid. | p.40 |
| Low hose heat. | Loose hose electrical connections. | Check connections. Repair as necessary. | p.40 |
| Low hose heat. | Ambient temperature is to low | Relocate hoses to a warmer area or increase A and B setpoints. | p.40 |
| Primary Heater(s) does not heat. | Heat turned off. | Turn on heat zones. | p.41 |
| Primary Heater(s) does not heat. | Temperature control alarm. | Check ADM for error codes. | p.41 |
| Primary Heater(s) does not heat. | Signal failure from RTD. | p.41 | |
| Control of primary heat is abnormal; high temperature overshoots (T4DA, T4DB) occurs intermittently. | Dirty RTD connections. | Examine RTD cables connected to TCMs. Confirm RTDs are not plugged into opposite heat zone. Unplug and re-plug RTD connectors. Unplug and re-plug RTD connectors. Ensure RTD tip contacts the heater element. | p.41 |
| Control of primary heat is abnormal; high temperature overshoots (T4DA, T4DB) occurs intermittently. | RTD not contacting heater element. | Loosen ferrule nut, push in RTD so tip contacts heater element. Holding RTD tip against heater element, tighten ferrule nut 1/4 turn past tight. | p.41 |
| Control of primary heat is abnormal; high temperature overshoots (T4DA, T4DB) occurs intermittently. | Failed heater element. | See Replace Heater Element, page 60. | p.41 |
| Control of primary heat is abnormal; high temperature overshoots (T4DA, T4DB) occurs intermittently. | Signal failure from RTD. | See (T6DA, T6DB), Error Codes. | p.41 |
| No module status LEDs are illuminated. | No power to cellular module. | Turn Reactor ON. | p.42 |
| No module status LEDs are illuminated. | Ensure unit is properly installed. | p.42 | |
| No module status LEDs are illuminated. | Verify 24V at output of the power supply. | p.42 | |
| No module status LEDs are illuminated. | Make sure the M8, 4–pin to M12, 8–pin cable is installed between cellular module and power supply. | p.42 | |
| Has not identified GPS location (green module status LED flashing). | Still identifying location. | Wait a few minutes for the unit to identify the location. | p.42 |
| Has not identified GPS location (green module status LED flashing). | Unable to identify location. In a location where GPS lock cannot occur. Buildings and warehouses often prevent GPS locks. | Move system to a location with a clear view of the sky. | p.42 |
| Has not identified GPS location (green module status LED flashing). | Use extension cable 16X521 and move cellular module to a location with a clear view of the sky. | p.42 | |
| Has not established cellular connection (orange module status LED flashing). | Still establishing cellular connection. | Wait a few minutes for the unit to establish the connection. | p.42 |
| Has not established cellular connection (orange module status LED flashing). | Unable to establish cellular connection. | Move system to a location with cellular service to establish cellular connection. | p.42 |
| Has not established cellular connection (orange module status LED flashing). | Use extension cable 16X521 and move cellular module to a location with a clear view of the sky. | p.42 | |
| Cannot view data for my unit(s) on website. | Graco InSite unit has not been activated. | Activate unit. See Registering and Activating the Graco InSite section. | p.42 |
| Temperature data not displayed on website. | Reactor temperature measurement is not working. | See System troubleshooting section. | p.42 |
| Hose zone temperature data not displayed on website. | The RTD or thermocouple is not correctly installed on the hose or is broken. | See RTD or Thermocouple repair section. | p.42 |
| Pressure data not displayed on website. | Reactor pressure measurement is not working. | See System troubleshooting section. | p.42 |