tocp.1Contentsp.2Warningsp.3Important Isocyanate Informationp.7Isocyanate Conditionsp.7Material Self-Ignitionp.8Keep Components A and B Separatep.8Changing Materialsp.8Moisture Sensitivity of Isocyanatesp.8Foam Resins with 245 fa Blowing Agentsp.8Modelsp.9Reactor 2 E-30 and E-30 Elitep.9Reactor 2 E-XP2 and E-XP2 Elitep.10Approvalsp.11Accessoriesp.11Supplied Manualsp.12Related Manualsp.12Component Manuals in English:p.12Troubleshootingp.13Troubleshoot Errorsp.13Error Codesp.13Systemp.35Hose Heat Systemp.37Primary Heaterp.41Graco InSitep.42Pressure Relief Procedurep.43Shutdownp.44Flushingp.46Repairp.47Before Beginning Repairp.47Flush Inlet Strainer Screenp.47Change Pump Lubricantp.48Remove Pumpp.49Install Pumpp.50Repair Drive Housingp.51Removalp.51Installationp.53Repair Electric Motorp.54Removalp.54Installationp.54Repair Circuit Breaker Modulep.55Figure 8 Circuit Breakersp.55Replace Fluid Inlet Sensorp.56Replace Pressure Transducersp.56Replace Fansp.57Replace Motor Fanp.57Replace Electrical Enclosure Fanp.57Replace Transformer Fanp.59Repair Primary Heaterp.60Replace Heater Elementp.60Repair Overtemperature Switchp.62Replace RTDp.63Repair Heated Hosep.64Check Hose Heat Power Connectorsp.64Check RTD Cables and FTSp.65Repair Fluid Temperature Sensor (FTS)p.66Installationp.66Test/Removalp.66Transformer Primary Checkp.67Transformer Secondary Checkp.67Replace Transformerp.68Replace Power Supplyp.69Replace Surge Protectorp.69Replace Advanced Display Module (ADM)p.69Replace Motor Control Module (MCM)p.70Software Update Procedurep.70Replace Temperature Control Module (TCM)p.70Partsp.71Proportionersp.71Proportioner Modulep.7824V150, Module for E-3024V151, Module for E-XP2p.78Fluid Heaterp.8024U843 — 10kW, 2–zone24U842 — 7.5 kW, 1–zonep.80Fluid Manifoldp.8224U844p.8224U844, Fluid Manifoldp.83Electrical Enclosurep.84Electrical Enclosurep.85System DIN Rail and Harness Module Kitp.8624U850, System DIN Rail and Harness Module Kitp.86Heater and Transformer Terminal Block Modulep.8724U849p.87System Circuit Breaker Modulep.8816U526p.88Power Supply and Terminal Block Modulep.8816U522p.88Fluid Inlet Kitsp.8924U320, Standard24U321, Elitep.89Electrical Schematicsp.91Reactor 2 Repair Spare Parts Referencep.94Recommended Common Spare Partsp.94Performance Chartsp.95Proportioners For Foamp.95Proportioners For Coatingsp.96Technical Specificationsp.98Notesp.100Graco Extended Warranty for Reactor® 2 Componentsp.101Graco Informationp.102tablesp.1Table 1 Fusion Air Purge, Round Patternp.96Table 2 Fusion Air Purge, Flat Patternp.96Table 3 Fusion Mechanical Purge, Round Patternp.97Table 4 Fusion Mechanical Purge, Flat Patternp.97
Page 1 of the Graco 333024F user manual — WLE
Page 1 · click to enlarge
Page 1

Repair-Parts

Reactor 2 E-30 and E-XP2

Proportioning System 333024F EN

Electric, Heated, Plural Component Proportioning System. For spraying polyurethane foam and polyurea coatings. For professional use only. Not approved for use in explosive atmospheres or hazardous locations.

Graco 333024F — Repair-Parts diagram (page 1)
Fig. 1 · Repair-Parts

WLE

PROVEN QUALITY. LEADING TECHNOLOGY.

Page 2 of the Graco 333024F user manual — Table of Contents
Page 2 · Contents
Contents

Contents

tocp.1Contentsp.2Warningsp.3Important Isocyanate Informationp.7Isocyanate Conditionsp.7Material Self-Ignitionp.8Keep Components A and B Separatep.8Changing Materialsp.8Moisture Sensitivity of Isocyanatesp.8Foam Resins with 245 fa Blowing Agentsp.8Modelsp.9Reactor 2 E-30 and E-30 Elitep.9Reactor 2 E-XP2 and E-XP2 Elitep.10Approvalsp.11Accessoriesp.11Supplied Manualsp.12Related Manualsp.12Component Manuals in English:p.12Troubleshootingp.13Troubleshoot Errorsp.13Error Codesp.13Systemp.35Hose Heat Systemp.37Primary Heaterp.41Graco InSitep.42Pressure Relief Procedurep.43Shutdownp.44Flushingp.46Repairp.47Before Beginning Repairp.47Flush Inlet Strainer Screenp.47Change Pump Lubricantp.48Remove Pumpp.49Install Pumpp.50Repair Drive Housingp.51Removalp.51Installationp.53Repair Electric Motorp.54Removalp.54Installationp.54Repair Circuit Breaker Modulep.55Figure 8 Circuit Breakersp.55Replace Fluid Inlet Sensorp.56Replace Pressure Transducersp.56Replace Fansp.57Replace Motor Fanp.57Replace Electrical Enclosure Fanp.57Replace Transformer Fanp.59Repair Primary Heaterp.60Replace Heater Elementp.60Repair Overtemperature Switchp.62Replace RTDp.63Repair Heated Hosep.64Check Hose Heat Power Connectorsp.64Check RTD Cables and FTSp.65Repair Fluid Temperature Sensor (FTS)p.66Installationp.66Test/Removalp.66Transformer Primary Checkp.67Transformer Secondary Checkp.67Replace Transformerp.68Replace Power Supplyp.69Replace Surge Protectorp.69Replace Advanced Display Module (ADM)p.69Replace Motor Control Module (MCM)p.70Software Update Procedurep.70Replace Temperature Control Module (TCM)p.70Partsp.71Proportionersp.71Proportioner Modulep.7824V150, Module for E-3024V151, Module for E-XP2p.78Fluid Heaterp.8024U843 — 10kW, 2–zone24U842 — 7.5 kW, 1–zonep.80Fluid Manifoldp.8224U844p.8224U844, Fluid Manifoldp.83Electrical Enclosurep.84Electrical Enclosurep.85System DIN Rail and Harness Module Kitp.8624U850, System DIN Rail and Harness Module Kitp.86Heater and Transformer Terminal Block Modulep.8724U849p.87System Circuit Breaker Modulep.8816U526p.88Power Supply and Terminal Block Modulep.8816U522p.88Fluid Inlet Kitsp.8924U320, Standard24U321, Elitep.89Electrical Schematicsp.91Reactor 2 Repair Spare Parts Referencep.94Recommended Common Spare Partsp.94Performance Chartsp.95Proportioners For Foamp.95Proportioners For Coatingsp.96Technical Specificationsp.98Notesp.100Graco Extended Warranty for Reactor® 2 Componentsp.101Graco Informationp.102tablesp.1Table 1 Fusion Air Purge, Round Patternp.96Table 2 Fusion Air Purge, Flat Patternp.96Table 3 Fusion Mechanical Purge, Round Patternp.97Table 4 Fusion Mechanical Purge, Flat Patternp.97
Page 3 of the Graco 333024F user manual — Warnings
Page 3 · click to enlarge
Page 3

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING ELECTRIC SHOCK HAZARD This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock. • Turn off and disconnect power at main switch before disconnecting any cables and before servicing or installing equipment. • Connect only to grounded power source. • All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations. • Do not expose to rain. Store indoors. TOXIC FLUID OR FUMES Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled or swallowed. • Read Safety Data Sheet (SDS) for handling instructions and to know the specific hazards of the fluids you are using, including the effects of long-term exposure. • When spraying, servicing equipment, or when in the work area, always keep work area well ventilated and always wear appropriate personal protective equipment. See Personal Protective Equipment warnings in this manual. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. PERSONAL PROTECTIVE EQUIPMENT Always wear appropriate personal protective equipment and cover all skin when spraying, servicing equipment, or when in the work area. Protective equipment helps prevent serious injury, including long-term exposure; inhalation of toxic fumes, mists or vapors; allergic reaction; burns; eye injury and hearing loss. This protective equipment includes but is not limited to: • A properly fitting respirator, which may include a supplied-air respirator, chemically impermeable gloves, protective clothing and foot coverings as recommended by the fluid manufacturer and local regulatory authority. • Protective eyewear and hearing protection.
Page 4 of the Graco 333024F user manual — Warnings
Page 4 · click to enlarge
Page 4
WARNING SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Do not spray without tip guard and trigger guard installed. • Engage trigger lock when not spraying. • Do not point gun at anyone or at any part of the body. • Do not put your hand over the spray tip. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing equipment. • Tighten all fluid connections before operating the equipment. • Check hoses and couplings daily. Replace worn or damaged parts immediately. FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. • Ground all equipment in the work area. See Grounding instructions. • Use only grounded hoses. • Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they are antistatic or conductive. • Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until you identify and correct the problem. • Keep a working fire extinguisher in the work area. THERMAL EXPANSION HAZARD Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure due to the thermal expansion. Over-pressurization can result in equipment rupture and serious injury. • Open a valve to relieve the fluid expansion during heating. • Replace hoses proactively at regular intervals based on your operating conditions.
Page 5 of the Graco 333024F user manual — Warnings
Page 5 · click to enlarge
Page 5
WARNING PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage. • Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents. • Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for compatibility. PLASTIC PARTS CLEANING SOLVENT HAZARD Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage. • Use only compatible water-based solvents to clean plastic structural or pressure-containing parts. • See Technical Data in this and all other equipment instruction manuals. Read fluid and solvent manufacturer’s MSDSs and recommendations. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer. • Do not leave the work area while equipment is energized or under pressure. • Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards. • Make sure all equipment is rated and approved for the environment in which you are using it. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. MOVING PARTS HAZARD Moving parts can pinch, cut or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure and disconnect all power sources.
Page 6 of the Graco 333024F user manual — BURN HAZARD
Page 6 · click to enlarge
Page 6

WARNING

BURN HAZARD

Equipment surfaces and fluid that is heated can become very hot during operation. To avoid severe burns:

  • Do not touch hot fluid or equipment.
Page 7 of the Graco 333024F user manual — Isocyanate Conditions
Page 7 · click to enlarge
Page 7

Important Isocyanate Information

Isocyanates (ISO) are catalysts used in two component materials.

Isocyanate Conditions

Spraying or dispensing fluids that contain isocyanates creates potentially harmful mists, vapors, and atomized particulates.

  • Read and understand the fluid manufacturer’s warnings and Safety Data Sheet (SDS) to know specific hazards and precautions related to isocyanates.
  • Use of isocyanates involves potentially hazardous procedures. Do not spray with this equipment unless you are trained, qualified, and have read and understood the information in this manual and in the fluid manufacturer’s application instructions and SDS.
  • Use of incorrectly maintained or mis-adjusted equipment may result in improperly cured material, which could cause off gassing and offensive odors. Equipment must be carefully maintained and adjusted according to instructions in the manual.
  • To prevent inhalation of isocyanate mists, vapors and atomized particulates, everyone in the work area must wear appropriate respiratory protection. Always wear a properly fitting respirator, which may include a supplied-air respirator. Ventilate the work area according to instructions in the fluid manufacturer’s SDS.
  • Avoid all skin contact with isocyanates. Everyone in the work area must wear chemically impermeable gloves, protective clothing and foot coverings as recommended by the fluid manufacturer and local regulatory authority. Follow all fluid manufacturer recommendations, including those regarding handling of contaminated clothing. After spraying, wash hands and face before eating or drinking.
  • Hazard from exposure to isocyanates continues after spraying. Anyone without appropriate personal protective equipment must stay out of the work area during application and after application for the time period specified by the fluid manufacturer. Generally this time period is at least 24 hours.
  • Warn others who may enter work area of hazard from exposure to isocyanates. Follow the recommendations of the fluid manufacturer and local regulatory authority. Posting a placard such as the following outside the work area is recommended:
Graco 333024F — Isocyanate Conditions diagram (page 7)
Fig. 2 · Isocyanate Conditions
Page 8 of the Graco 333024F user manual — Foam Resins with 245 fa Blowing Agents
Page 8 · click to enlarge
Page 8

Material Self-Ignition

Moisture Sensitivity of Isocyanates

Exposure to moisture (such as humidity) will cause ISO to partially cure, forming small, hard, abrasive crystals that become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity.

Some materials may become self-igniting if applied too thick. Read material manufacturer’s warnings and SDS.

NOTICE

Partially cured ISO will reduce performance and the life of all wetted parts.

Keep Components A and B Separate

  • Always use a sealed container with a desiccant dryer in the vent, or a nitrogen atmosphere. Never store ISO in an open container.
  • Keep the ISO pump wet cup or reservoir (if installed) filled with appropriate lubricant. The lubricant creates a barrier between the ISO and the atmosphere.

Cross-contamination can result in cured material in fluid lines which could cause serious injury or damage to equipment. To prevent cross-contamination:

  • Use only moisture-proof hoses compatible with ISO.
  • Never interchange component A and component B wetted parts.
  • Never use reclaimed solvents, which may contain moisture. Always keep solvent containers closed when not in use.
  • Never use solvent on one side if it has been contaminated from the other side.

Changing Materials

  • Always lubricate threaded parts with an appropriate lubricant when reassembling.

NOTICE

Changing the material types used in your equipment requires special attention to avoid equipment damage and downtime.

Foam Resins with 245 fa Blowing Agents

  • When changing materials, flush the equipment multiple times to ensure it is thoroughly clean.
  • Always clean the fluid inlet strainers after flushing.

Some foam blowing agents will froth at temperatures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system.

  • Check with your material manufacturer for chemical compatibility.
  • When changing between epoxies and urethanes or polyureas, disassemble and clean all fluid components and change hoses. Epoxies often have amines on the B (hardener) side. Polyureas often have amines on the B (resin) side.
Page 9 of the Graco 333024F user manual — Reactor 2 E-30 and E-30 Elite
Page 9 · click to enlarge
Page 9

Models

Reactor 2 E-30 and E-30 Elite

All elite systems include fluid inlet pressure and temperature sensors, Graco InSite™, and Xtreme-Wrap 50 ft (15 m) head hose. For part numbers, see Accessories, page 11

ModelE-30 ModelE-30 Elite Model 10 kW15 kW10 kW15kW Proportioner ★272010272011272110272111 Maximum Fluid Working Pressure psi (MPa, bar)2000 (14, 140)2000 (14, 140)2000 (14, 140)2000 (14, 140) Approximate Output per Cycle (A+B) gal. (liter)0.0272 (0.1034)0.0272 (0.1034)0.0272 (0.1034)0.0272 (0.1034) Max Flow Rate lb/min (kg/min)30 (13.5)30 (13.5)30 (13.5)30 (13.5) Total System Load † (Watts)17,90023,00017,90023,000 Configurable Voltage Phase230 1Ø230 3Ø∆400 3ØY230 1Ø230 3Ø∆400 3ØY230 1Ø230 3Ø∆400 3ØY230 1Ø230 3Ø∆400 3ØY Full Load Peak Current*78503410062357850341006235
Fusion AP Package (Gun Part No.)AP2010 (246102)AH2010 (246102)AP2011 (246102)AH2011 (246102)AP2110 (246102)AH2110 (246102)AP2111 (246102)AH2111 (246102) Fusion CS Package (Gun Part No.)CS2010 (CS02RD)CH2010 (CS02RD)CS2011 (CS02RD)CH2011 (CS02RD)CS2110 (CS02RD)CH2110 (CS02RD)CS2111 (CS02RD)CH2111 (CS02RD) Probler P2 Package (Gun Part No.)P22010 (GCP2R2)PH2010 (GCP2R2)P22011 (GCP2R2)PH2011 (GCP2R2)P22110 (GCP2R2)PH2110 (GCP2R2)P22111 (GCP2R2)PH2111 (GCP2R2) Heated Hose 50 ft (15 m) 24K240 (scuff guard) 24Y240 (Xtreme-Wrap)24K24024K24024K24024K24024Y24024Y24024Y24024Y240 Qty: 1Qty: 5Qty: 1Qty: 5Qty: 1Qty: 5Qty: 1Qty: 5 Heated Whip Hose 10 ft (3 m) ™246050246050246050246050 Graco Insite✓✓ Fluid Inlet Sensors (2)✓✓

* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.

Packages include gun, heated hose, and whip hose. Elite packages also include Graco InSite and fluid inlet sensors.

Low line input voltage will reduce power available and heaters will not perform at full capacity.

Total system watts used by system, based on maximum heated hose length for each unit.

  • E–30 and E–XP2 series: 310 ft (94.5 m) maximum heated hose length, including whip hose.
Voltage Configurations Key ØPhase ∆DELTA YWYE

★ See Approvals, page 11.

Models

Page 10 of the Graco 333024F user manual — Reactor 2 E-XP2 and E-XP2 Elite
Page 10 · click to enlarge
Page 10

Reactor 2 E-XP2 and E-XP2 Elite

All elite systems include fluid inlet pressure and temperature sensors, Graco InSite™, and Xtreme-Wrap 50 ft (15 m) head hose. For part numbers, see Accessories, page 11

ModelE–XP2 ModelE–XP2 Elite Model 15 kW15 kW Proportioner ★272012272112 Maximum Fluid Working Pressure psi (MPa, bar)3500 (24.1, 241)3500 (24.1, 241) Approximate Output per Cycle (A+B) gal. (liter)0.0203 (0.0771)0.0203 (0.0771) Max Flow Rate gpm/min (l/min)2 (7.6)2 (7.6) Total System Load † (Watts)23,00023,000 Configurable Voltage Phase230 1Ø230 3Ø∆400 3ØY230 1Ø230 3Ø∆400 3ØY Full Load Peak Current (amps)*10062351006235 Fusion AP Package (Gun Part No.)AP2012 (246100)AP2112 (246100) Probler P2 Package (Gun Part No.)P22012 (GCP2R0)P22112 (GCP2R0) Heated Hose 50 ft (15 m)24K241 (scuff guard)24Y241 (Xtreme-Wrap) Heated Whip Hose 10 ft (3 m) ™246055246055 Graco InSite✓ Fluid Inlet Sensors (2)✓

* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix chamber sizes may be less.

Packages include gun, heated hose, and whip hose. Elite packages also include Graco InSite and fluid inlet sensors.

Low line input voltage will reduce power available and heaters will not perform at full capacity.

Total system watts used by system, based on maximum heated hose length for each unit.

  • E–30 and E–XP2 series: 310 ft (94.5 m) maximum heated hose length, including whip hose.
Voltage Configurations Key ØPhase ∆DELTA YWYE

★ See Approvals, page 11.

Models

Page 11 of the Graco 333024F user manual — Approvals
Page 11 · click to enlarge
Page 11

Approvals

Accessories

Kit NumberDescription 24U315Air Manifold Kit (4 outlets) 24U314Wheel and Handle Kit 24T280Graco InSite Kit 16X521Graco InSite Extension cable 24.6 ft (7.5 m) 24N44950 ft (15 m) CAN cable (for remote display module) 24K207Fluid Temperature Sensor (FTS) with RTD 24U174Remote Display Module Kit 24K337Light Tower Kit 15V551ADM Protective Covers (10 pack) 15M483Remote Display Module Protective Covers (10 pack) 24M174Drum Level Sticks 121006150 ft (45 m) CAN cable (for remote display module) 24N365RTD Test Cables (to aide resistance measurements)

Intertek approvals apply to proportioners without hoses.

Proportioner Approvals:

Conforms to ANSI/UL Std. 499 Certified to CAN/CSA Std. C22.2 No. 88

Approvals · 9902471

Page 12 of the Graco 333024F user manual — Component Manuals in English:
Page 12 · click to enlarge
Page 12

Supplied Manuals

The following manuals are shipped with the Reactor 2. Refer to these manuals for detailed equipment information.

Manuals are also available at www.graco.com

ManualDescription 333023Reactor 2 E-30 and E-XP2 Operation 333091Reactor 2 E-30 and E-XP2 Startup Quick Guide 333092Reactor 2 E-30 and E-XP2 Shutdown Quick Guide

The following manuals are for accessories used with the Reactor.

Component Manuals in English:

Manuals are available at www.graco.com

System Manuals 333023Reactor 2 E-30 and E-XP2 Operation Displacement Pump Manual 309577Electric Reactor Displacement Pump, Repair-Parts Feed System Manuals 309572Heated Hose, Instructions-Parts 309852Circulation and Return Tube Kit, Instructions-Parts 309815Feed Pump Kits, Instructions-Parts 309827Feed Pump Air Supply Kit, Instructions-Parts Spray Gun Manuals 309550Fusion ™ AP Gun 312666Fusion ™ CS Gun 313213Probler® P2 Gun Accessory Manuals 3A1905Feed Pump Shutdown Kit, Instructions-Parts 3A1906Light Tower Kit, Instructions-Parts 3A1907Remote Display Module Kit, Instructions-Parts 332735Air Manifold Kit, Instructions-Parts 332736Handle and Wheel Kit, Instructions-Parts 333276Graco InSite ™Kit, Instructions-Parts

Supplied Manuals

Page 13 of the Graco 333024F user manual — Error Codes
Page 13 · click to enlarge
Page 13
1. Press the soft key for help with the active error.
Graco 333024F — Troubleshooting diagram (page 13)
Fig. 3 · Troubleshooting

Troubleshoot Errors

There are three types of errors that can occur. Errors are indicated on the display as well as by the light tower (optional).

A parameter critical to the process has reached a level requiring the system to stop. The alarm needs to be addressed immediately.

to return to the previously displayed screen.

2. The QR code screen will be displayed. Scan the QR code with your smartphone to be sent directly to online troubleshooting for the active error code. Otherwise, manually navigate to http://help.graco.com and search for the active error.

A parameter critical to the process has reached a level requiring attention, but not sufficient enough to stop the system at this time.

Graco 333024F — Troubleshoot Errors diagram (page 13)
Fig. 4 · Troubleshoot Errors

A parameter that is not immediately critical to the process. The advisory needs attention to prevent more serious issues in the future.

See Error Codes, page 13 for causes and solutions to each error code.

To troubleshoot the error:

3. If no internet connection is available, see Error Codes, page 13 for causes and solutions for each error code.

Error Codes

When an error occurs be sure to determine the code before resetting it. If you forget which error code occurred, see the Errors screen to view the last 200 errors, with date, time, and description.

Show 6 more labels / short text on this page
Error Description · Alarms · Press · or · Deviations · Advisories
Page 14 of the Graco 333024F user manual — A1NM MCM
Page 14 · click to enlarge
Page 14

Error Location Type Description Cause Solution

A1NM MCM

Loose/broken connection.

Check for loose wire terminations at MCM motor connector.

Bad Motor. Disconnect motor output connector from MCM. Confirm less than 8 ohms resistance between each pair of motor power leads (M1 to M2, M1 to M3, M2 to M3). If any readings greater than 8 ohms, check motor wiring for damage and/or loose terminations.

Check wiring for touching wires. A4DA Heater A

Short circuit in heater wiring.

Bad Heater. Confirm resistance of heater. Heater resistance should be 18–21 Ω for each heater element, 9–12 Ω combined for 10 kW systems, and 6-8 Ω for 15 kW systems. If out of tolerance, replace heater element.

Check wiring for touching wires. A4DB Heater B

Short circuit in heater wiring.

Bad Heater. Confirm resistance of heater. Heater resistance should be 9-12 Ω for 10 kW systems and 6-8 Ω for 15 kW systems. If out of tolerance, replace heater.

High Current Hose Short circuit in hose wiring.

Check continuity of transformer windings. Normal readings are about 0.2Ω on both primary and secondary. If reading is 0Ω replace transformer.

Check for shorts between the primary winding and the support frame or enclosure.

Show 4 more labels / short text on this page
Low Motor Current · High Current A · High Current B · A4DH Hose
Page 15 of the Graco 333024F user manual — A4NM MCM
Page 15 · click to enlarge
Page 15

Error Location Type Description Cause Solution

A4NM MCM

Short circuit of motor wiring.

Check wiring to the motor to ensure no bare wires are touching and that no wires are shorted to ground.

Motor will not rotate.

Remove pump gear housings from motor and check that motor shaft rotates freely in direction indicated on motor housing.

Damaged gear train.

Check pump gear trains for damage and repair or replace as necessary.

Chemical pump is stuck.

Repair or replace chemical pump.

Shorted TCM If error cannot be cleared or regenerates consistently, replace module.

Shorted TCM If error cannot be cleared or regenerates consistently, replace module.

Shorted TCM If error cannot be cleared or regenerates consistently, replace module.

Show 7 more labels / short text on this page
High Motor Current · A7DA Heater A · Unexpected Current A · A7DB Heater B · Unexpected Current B · A7DH Hose · Unexpected Current Hose
Page 16 of the Graco 333024F user manual — CACM MCM
Page 16 · click to enlarge
Page 16

Error Location Type Description Cause Solution

Tripped circuit breaker.

Visually check circuit breaker for a tripped condition.

Loose/broken connection.

Check heater wiring for loose wires.

Tripped circuit breaker.

Visually check circuit breaker for a tripped condition.

Loose/broken connection.

Check heater wiring for loose wires.

Tripped circuit breaker.

Visually check circuit breaker for a tripped condition.

Loose/broken connection.

Check heater wiring for loose wires.

CACM MCM

Module does not have software.

Insert a system token into the ADM module and cycle the power. Wait until the upload is complete before removing the token.

Dial set to wrong position.

Ensure the MCM dial is set to the correct position: 2 for E-30, 3 for E-XP2

No 24 VDC supply to module.

Green light on each module should be lit. If green light is not lit, check to make sure each CAN cable connection is tight. Verify the power supply is outputting 24 VDC. If not, check power supply wiring. If wiring is okay, replace the power supply.

Loose or broken CAN cable.

Check the CAN cables running between GCA modules and tighten of needed. If the problem still persists move each cable around the connector and watch the flashing yellow light on the GCA modules. If the yellow light stops flashing, replace the CAN cable.

Show 7 more labels / short text on this page
A8DA Heater A · No Current A · A8DB Heater B · No Current B · A8DH Hose · No Current Hose · MCM Communica- tion Error
Page 17 of the Graco 333024F user manual — DADX MCM
Page 17 · click to enlarge
Page 17

Error Location Type Description Cause Solution

CACT TCM

Module does not have software.

Insert a system token into the ADM module and cycle the power. Wait until the upload is complete before removing the token.

No 24 VDC supply to module.

Green light on each module should be lit. If green light is not lit, check to make sure each CAN cable connection is tight. Verify the power supply is outputting 24 VDC. If not, check power supply wiring. If wiring is okay, replace the power supply.

Loose or broken CAN cable.

Check the CAN cables running between GCA modules and tighten of needed. If the problem still persists move each cable around the connector and watch the flashing yellow light on the GCA modules. If the yellow light stops flashing, replace the CAN cable.

DADX MCM

Pump Runaway Flow rate is too large.

Mix chamber too large for system selected. Use mix chamber rated for system.

Ensure the system has chemical and the feed pumps are operating correctly.

No material in pumps. Verify pumps are supplying chemical. If necessary, replace or refill drums.

Inlet ball valves are closed. Open ball valves.

Check wiring between cycle switch and MCM. DE0X MCM

Faulty or missing cycle switch.

Missing or out of place cycle switch magnet.

Check presence and position of cycle switch magnet on output crank arm.

TCM Communication Error · Cycle Switch Error

Page 18 of the Graco 333024F user manual — K8NM MCM
Page 18 · click to enlarge
Page 18

Error Location Type Description Cause Solution

EVCH ADM

Manual Hose Mode Enabled

Manual hose mode has been enabled in System Setup screen.

Install a functioning fluid temperature sensor (FTS) on the hose. Manual hose mode will automatically turn off.

EAUX ADM

USB Busy USB drive has been inserted to the ADM.

Do not remove USB drive until download/upload is complete.

EVUX ADM

USB disabled USB download/uploads are disabled.

Enable USB download/up- loads on the Advanced Setup screen before insert- ing a USB drive.

F9DX MCM

Mix chamber is too large for set pressure.

Reference the pressure flow curves and select a tip size that is the correct size for the set pressure.

Low Frequency A Line frequency is below 45 Hz

Ensure line frequency of incoming power is between 45 and 65 Hz.

Low Frequency B Line frequency is below 45 Hz

Ensure line frequency of incoming power is between 45 and 65 Hz.

Low Frequency Hose Line frequency is below 45 Hz

Ensure line frequency of incoming power is between 45 and 65 Hz.

High Frequency A Line frequency is above 65 Hz

Ensure line frequency of incoming power is between 45 and 65 Hz.

High Frequency B Line frequency is above 65 Hz

Ensure line frequency of incoming power is between 45 and 65 Hz.

Line frequency is above 65 Hz

Ensure line frequency of incoming power is between 45 and 65 Hz.

K8NM MCM

Motor will not rotate.

Remove pump gear housings from motor and check that motor shaft rotates freely in direction indicated on motor housing.

Damaged gear train.

Check motor/pump gear trains for damage and repair or replace as necessary.

Chemical pump is stuck.

Repair or replace chemical pump.

Show 9 more labels / short text on this page
High Pressure/Flow Cutback · H2MA Heater A · H2MB Heater B · H2MH Hose · H3MA Heater A · H3MB Heater B · H3MH Hose · High Frequency Hose · Locked Rotor Motor
Page 19 of the Graco 333024F user manual — P0AX MCM
Page 19 · click to enlarge
Page 19

Error Location Type Description Cause Solution

L1AX ADM

Low Chemical Level A

Low material level. Refill material and update drum level on ADM Maintenance screen.

Alarm can be disabled on the System Setup screen.

L1BX ADM

Low Chemical Level B

Low material level. Refill material and update drum level on ADM Maintenance screen.

Alarm can be disabled on the System Setup screen.

MMUX USB

Maintenance Due - USB

USB logs have reached a level where data loss will occur if logs are not downloaded.

Insert a USB drive into the ADM and download all logs.

P0AX MCM

Pressure Imbalance A High

Pressure difference between A and B material is greater than the defined value.

Ensure material flow is equally restricted on both material lines.

Pressure imbalance is defined too low.

Ensure that the pressure imbalance value, on the System Setup screen, is at an acceptable maximum pressure to prevent unnecessary alarms and abort dispenses.

Out of material. Fill tanks with material

Fluid leaking from heater inlet rupture disk.

Check if heater and PRESSURE RELIEF/SPRAY valve are plugged. Clear. Replace rupture disk. Do not replace with a pipe plug.

Feed system defective.

Check feed pump and hoses for blockage. Check that feed pumps have correct air pressure.

Page 20 of the Graco 333024F user manual — P0BX MCM
Page 20 · click to enlarge
Page 20

Error Location Type Description Cause Solution

P0BX MCM

Pressure Imbalance B High

Pressure difference between A and B material is greater than the defined value.

Ensure material flow is equally restricted on both material lines.

Pressure imbalance is defined too low.

Ensure that the pressure imbalance value, on the System Setup screen, is at an acceptable maximum pressure to prevent unnecessary alarms and abort dispenses.

Out of material. Fill tanks with material

Fluid leaking from heater inlet rupture disk.

Check if heater and PRESSURE RELIEF/SPRAY valve are plugged. Clear. Replace rupture disk. Do not replace with a pipe plug.

Feed system defective.

Check feed pump and hoses for blockage. Check that feed pumps have correct air pressure.

Ensure that inlet pressure to the pump is sufficient. P1FA MCM

Low Inlet Pressure A

Inlet pressure lower than defined value.

Value defined too high.

Ensure that the low pressure alarm level defined on the System Setup screen is acceptable.

Ensure that inlet pressure to the pump is sufficient. P1FB MCM

Low Inlet Pressure B

Inlet pressure lower than defined value.

Value defined too high.

Ensure that the low pressure alarm level defined on the System Setup screen is acceptable.

Ensure that inlet pressure to the pump is sufficient. P2FA MCM

Low Inlet Pressure A

Inlet pressure lower than defined value.

Value defined too high.

Ensure that the low pressure alarm level defined on the System Setup screen is acceptable.

Page 21 of the Graco 333024F user manual — P4BX MCM
Page 21 · click to enlarge
Page 21

Error Location Type Description Cause Solution

Ensure that inlet pressure to the pump is sufficient. P2FB MCM

Low Inlet Pressure B

Inlet pressure lower than defined value.

Value defined too high.

Ensure that the low pressure alarm level defined on the System Setup screen is acceptable.

P4AX MCM

System pressurized before allowing heat to reach setpoint.

Pressure in the hose and pumps will increase as the system heats up. Turn on heat and allow all zones to reach the temperature setpoint before turning on the pumps.

Bad pressure transducer.

Verify the ADM pressure reading and the analog gauges at the manifold.

E-XP2 system configured as E-30.

Alarm level is lower for E-30 than for E-XP2. Ensure dial on MCM is set to position "3" for E-XP2.

P4BX MCM

System pressurized before allowing heat to reach setpoint.

Pressure in the hose and pumps will increase as the system heats up. Turn on heat and allow all zones to reach the temperature setpoint before turning on the pumps.

Bad pressure transducer.

Verify the ADM pressure reading and the analog guages at the manifold.

E-XP2 system configured as E-30.

Alarm level is lower for E-30 than for E-XP2. Ensure dial on MCM is set to position "3" for E-XP2.

High Pressure A · High Pressure B

Page 22 of the Graco 333024F user manual — P6FA MCM
Page 22 · click to enlarge
Page 22

Error Location Type Description Cause Solution

P6AX MCM

Pressure Sensor Error A

Loose/bad connection.

Check to ensure the pressure transducer is properly installed and all wires are properly connected.

Bad sensor. Check if the error follows the transducer. Disconnect transducer cables from the MCM (connectors 6 and 7). Reverse A and B connections and check if the errors follows. If the error follows the transducer, replace the pressure transducer.

P6BX MCM

Pressure Sensor Error B

Loose/bad connection.

Check to ensure the pressure transducer is properly installed and all wires are properly connected.

Bad sensor. Check if the error follows the transducer. Disconnect transducer cables from the MCM (connectors 6 and 7). Reverse A and B connections and check if the errors follows. If the error follows the transducer, replace the pressure transducer.

P6FA MCM

Pressure Sensor Error Inlet A

Inlet sensors not installed.

If inlet sensors are not installed, inlet sensors should be disabled on the System Setup screen.

Loose/bad connection.

Check to ensure inlet sensor is properly installed and all wires are properly connected.

Bad sensor. Check if the error follows the inlet sensor. Disconnect inlet sensor cables from the MCM (connectors 8 and 9). Reverse A and B connections and check if the errors follows. If the error follows the sensor, replace the inlet sensor.

Page 23 of the Graco 333024F user manual — P7AX MCM
Page 23 · click to enlarge
Page 23

Error Location Type Description Cause Solution

P6FB MCM

Pressure Sensor Error Inlet B

Inlet sensors not installed.

If inlet sensors are not installed, inlet sensors should be disabled on the System Setup screen.

Loose/bad connection.

Check to ensure inlet sensor is properly installed and all wires are properly connected.

Bad sensor. Check if the error follows the inlet sensor. Disconnect inlet sensor cables from the MCM (connectors 8 and 9). Reverse A and B connections and check if the errors follows. If the error follows the sensor, replace the inlet sensor.

P7AX MCM

Pressure Imbalance A High

Pressure difference between A and B material is greater than the defined value.

Ensure material flow is equally restricted on both material lines.

Pressure imbalance is defined too low.

Ensure that the pressure imbalance value, on the System Setup screen, is at an acceptable maximum pressure to prevent unnecessary alarms and abort dispenses.

Out of material. Fill tanks with material

Fluid leaking from heater inlet rupture disk.

Check if heater and PRESSURE RELIEF/SPRAY valve are plugged. Clear. Replace rupture disk. Do not replace with a pipe plug.

Feed system defective.

Check feed pump and hoses for blockage. Check that feed pumps have correct air pressure.

Page 24 of the Graco 333024F user manual — P7BX MCM
Page 24 · click to enlarge
Page 24

Error Location Type Description Cause Solution

P7BX MCM

Pressure Imbalance B High

Pressure difference between A and B material is greater than the defined value.

Ensure material flow is equally restricted on both material lines.

Pressure imbalance is defined too low.

Ensure that the pressure imbalance value, on the System Setup screen, is at an acceptable maximum pressure to prevent unnecessary alarms and abort dispenses.

Out of material. Fill tanks with material

Fluid leaking from heater inlet rupture disk.

Check if heater and PRESSURE RELIEF/SPRAY valve are plugged. Clear. Replace rupture disk. Do not replace with a pipe plug.

Feed system defective.

Check feed pump and hoses for blockage. Check that feed pumps have correct air pressure.

Flow is too high at current setpoint.

Use a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint.

Bad RTD or bad RTD placement against heater.

Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.

Bad heater rod or loose heater wire.

Confirm resistance of heater. Heater resistance should be 9-12 Ω for 10 kW systems and 6-8 Ω for 15 kW systems. If out of tolerance, check for loose heater rod wire(s). Reconnect wires or replace heater rod if necessary.

T2DA Heater A · Low Temperature A

Page 25 of the Graco 333024F user manual — T2FB MCM
Page 25 · click to enlarge
Page 25

Error Location Type Description Cause Solution

Flow is too high at current setpoint.

Use a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint.

Bad RTD or bad RTD placement against heater.

Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.

Bad heater rod or loose heater wire.

Confirm resistance of heater. Heater resistance should be 9-12 Ω for 10 kW systems and 6-8 Ω for 15 kW systems. If out of tolerance, check for loose heater rod wire(s). Reconnect wires or replace heater rod if necessary.

Flow is too high at current setpoint.

Use a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint.

Cold chemical in unheated portion of system passed hose FTS at startup.

Recirculate heated chemical back to drum in cold conditions before startup.

T2FA MCM

Low Temperature Inlet A

Inlet fluid temperature is below the defined level.

Recirculate fluid through heaters until inlet fluid temperature is above defined error level.

Increase the low temperature deviation level on the System Setup screen.

T2FB MCM

Low Temperature Inlet B

Inlet fluid temperature is below the defined level.

Recirculate fluid through heaters until inlet fluid temperature is above defined error level.

Increase the low temperature deviation level on the System Setup screen.

Show 4 more labels / short text on this page
T2DB Heater B · Low Temperature B · T2DH Hose · Low Temperature Hose
Page 26 of the Graco 333024F user manual — T4CM MCM
Page 26 · click to enlarge
Page 26

Error Location Type Description Cause Solution

Hose Cutback Hose current has been reduced because hose has been drawing current for an extended period.

Hose setpoint higher than A and B setpoints. Decrease hose setpoint.

Hose FTS is in a colder environment than the rest of the hose. Expose FTS to the same environment as the rest of the hose.

T3CT TCM

High ambient temperature.

Ensure ambient temperature is below 120°F(48°C) before using the system.

Enclosure fan not operating.

Ensure fan in electrical enclosure is spinning. If it is not, check fan wiring or replace fan.

Module fan not operating.

If a TCM fan error (WMI0) has occurred, fan inside the module is not working properly. Check TCM fan for debris and clear with forced air if necessary.

T3NM MCM

Motor is operating outside of the pressure flow curve.

The system is running at a lower setpoint to preserve motor life. Run the system at a lower duty cycle or with a smaller mix chamber.

Motor temperature is too high.

Ensure ambient temperature is below 120°F(48°C).

Verify that all fans are working.

T3CM MCM

Motor control temperature is too high.

Ensure ambient temperature is below 120°F(48°C).

Verify that all fans are working.

T4CM MCM

High ambient temperature.

Ensure ambient temperature is below 120°F(48°C) before using the system.

Enclosure fan not operating.

Ensure fan in electrical enclosure is spinning. If it is not, check fan wiring or replace fan.

Show 5 more labels / short text on this page
T3CH Hose · TCM Cutback · Motor Temperature Cutback · MCM Temperature Cutback · High Temperature MCM
Page 27 of the Graco 333024F user manual — T4CT TCM
Page 27 · click to enlarge
Page 27

Error Location Type Description Cause Solution

T4CT TCM

High ambient temperature.

Ensure ambient temperature is below 120°F(48°C) before using the system.

Enclosure fan not operating.

Ensure fan in electrical enclosure is spinning. If it is not, check fan wiring or replace fan.

Module fan not operating.

If a TCM fan error (WMI0) has occurred, fan inside the module is not working properly. Check TCM fan for debris and clear with forced air if necessary.

Bad RTD or bad RTD placement against heater.

Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.

Flow too high for temperature setpoint, causing temperature overshoots when gun is de-triggered.

Use a smaller mix chamber that is rated for the unit in use.

Bad RTD or bad RTD placement against heater.

Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.

Flow too high for temperature setpoint, causing temperature overshoots when gun is de-triggered.

Use a smaller mix chamber that is rated for the unit in use.

Show 5 more labels / short text on this page
High Temperature TCM · T4DA Heater A · High Temperature A · T4DB Heater B · High Temperature B
Page 28 of the Graco 333024F user manual — Troubleshooting
Page 28 · click to enlarge
Page 28

Error Location Type Description Cause Solution

Hose portion exposed to an excessive heat source, like hot sun or coiled hose, can pass fluid more than 27°F (15°C) over hose temperature setting to the FTS.

Shade exposed hose from hot sun or expose FTS to same environment when at rest. Uncoil entire hose before heating to avoid self-heating.

Setting the A or B setpoint much higher than hose setpoint can cause fluid more than 27°F (15°C) over hose temperature setting to reach the FTS.

Increase hose setpoint so it is closer to A and B setpoints.

High Temperature Switch A

Overtemperature switch sensed a fluid temperature above 230°F (110°C).

Heater was delivered too much power, causing the overtemperature switch to open. RTD is not reading properly. After the heater cools down, replace RTD. Switch closes and the error can be cleared when the heater temperature falls below 190°F (87°C).

Disconnected or loose overtemperature switch cable/connection.

If heater is not actually over temperature, check all wiring and connections between the TCM and the overtemperature switches.

Overtemperature switch failed in the open position.

Replace overtemperature switch.

T4DH Hose · High Temperature Hose · T4EA Heater A

Page 29 of the Graco 333024F user manual — T4NM MCM
Page 29 · click to enlarge
Page 29

Error Location Type Description Cause Solution

High Temperature Switch B

Overtemperature switch sensed a fluid temperature above 230°F (110°C).

Heater was delivered too much power, causing the overtemperature switch to open. RTD is not reading properly. After the heater cools down, replace RTD. Switch closes and the error can be cleared when the heater temperature falls below 190°F (87°C).

Disconnected or loose overtemperature switch cable/connection.

If heater is not actually over temperature, check all wiring and connections between the TCM and the overtemperature switches.

Overtemperature switch failed in the open position.

Replace overtemperature switch.

T4NM MCM

Cooling fan is not operating properly.

Check to see that the motor fan is moving. Measure voltage to fan. There should be 24 VDC. If no voltage is measured, check fan wiring. If the fan has voltage but is not moving, replace fan. If necessary use an air hose to blow out around the fan housings and remove any built-up debris.

Disconnected or loose motor temperature cable.

Verify wiring between the motor temperature sensor and the MCM.

High ambient temperature.

Ensure ambient temperature is below 120°F(48°C) before using the system.

Bad electric motor. Replace electric motor.

Check all wiring and connection to RTD. T6DA Heater A

Disconnected or loose RTD cable or connection.

Bad RTD. Switch the RTD with another and see if the error message follows the RTD. Replace RTD if the error follows the RTD.

T4EB Heater B · High Temperature Motor · Sensor Error A

Page 30 of the Graco 333024F user manual — T6DT TCM
Page 30 · click to enlarge
Page 30

Error Location Type Description Cause Solution

Check all wiring and connection to RTD. T6DB Heater B

Disconnected or loose RTD cable or connection.

Bad RTD. Switch the RTD with another and see if the error message follows the RTD. Replace RTD if the error follows the RTD.

Sensor Error Hose Disconnected or shorted RTD cable in hose or bad FTS.

Expose each hose RTD connection to check and retighten any loose con- nector. Measure hose RTD cable and FTS continuity. See Repair Heated Hose, page 64. Order RTD Test kit 24N365 for measure- ment.

Disconnect hose RTD and use manual hose mode to finish job until repair can be completed.

T6DT TCM

Shorted RTD cable in hose or FTS.

Expose each hose RTD connection to check for exposed and shorted RTD wires. Measure hose RTD cable and FTS continuity. See Repair Heated Hose, page 64. Order RTD Test kit 24N365 for measure- ment.

Disconnect hose RTD and use manual hose mode to finish job until repair can be completed.

Shorted A or B Heater RTD

If the error still occurs with the hose FTS unplugged, one of the heater RTDs is bad. Unplug the A or B RTD from the TCM. If unplugging an RTD fixes the T6DT error, replace the RTD.

Sensor Error B · T6DH Hose · Sensor Error TCM

Page 31 of the Graco 333024F user manual — V1CM MCM
Page 31 · click to enlarge
Page 31

Error Location Type Description Cause Solution

No Temperature Rise A

Bad RTD or bad RTD placement against heater.

Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.

Bad heater rod or loose heater wire.

Confirm resistance of heater. Heater resistance should be 9-12 Ω for 10 kW systems and 6-8 Ω for 15 kW systems. If out of tolerance, check for loose heater rod wire(s). Reconnect wires or replace heater rod if necessary.

Started spraying before heater reached operating temperature.

Wait until operating temperature has been reached before spraying or recirculating.

No Temperature Rise B

Bad RTD or bad RTD placement against heater.

Swap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD.

Bad heater rod or loose heater wire.

Confirm resistance of heater. Heater resistance should be 9-12 Ω for 10 kW systems and 6-8 Ω for 15 kW systems. If out of tolerance, check for loose heater rod wire(s). Reconnect wires or replace heater rod if necessary.

Started spraying before heater reached operating temperature.

Wait until operating temperature has been reached before spraying or recirculating.

No Temperature Rise Hose

Started spraying before heater reached operating temperature.

Wait until operating temperature has been reached before spraying or recirculating.

V1CM MCM

Loose/bad connection or tripped circuit breaker.

Check wiring for loose connection or tripped circuit breaker.

Low incoming line voltage.

Measure voltage at circuit breaker and ensure voltage is greater than 195 VAC.

Show 4 more labels / short text on this page
T8DA Heater A · T8DB Heater B · T8DH Hose · Low Voltage MCM
Page 32 of the Graco 333024F user manual — V3MA TCM
Page 32 · click to enlarge
Page 32

Error Location Type Description Cause Solution

V1IT TCM

Low Voltage CAN Bad 24 VDC power supply.

Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply.

V2IT TCM

Low Voltage CAN Bad 24 VDC power supply.

Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply.

V2MA TCM

Loose connection or tripped circuit breaker.

Check wiring for loose connection or tripped circuit breaker.

Low incoming line voltage.

Measure voltage at circuit breaker and ensure voltage is greater than 195 VAC.

V2MB TCM

Loose connection or tripped circuit breaker.

Check wiring for loose connection or tripped circuit breaker.

Low incoming line voltage.

Measure voltage at circuit breaker and ensure voltage is greater than 195 VAC.

V2MH TCM

Loose connection or tripped circuit breaker.

Check wiring for loose connection or tripped circuit breaker.

Low incoming line voltage.

Measure voltage at circuit breaker and ensure voltage is greater than 195 VAC.

V3IT TCM

High Voltage CAN Bad 24 VDC power supply.

Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply.

V3MA TCM

High Voltage A Incoming line voltage is too high.

Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.

Low Voltage A · Low Voltage B · Low Voltage Hose

Page 33 of the Graco 333024F user manual — V4MH TCM
Page 33 · click to enlarge
Page 33

Error Location Type Description Cause Solution

V3MB TCM

High Voltage B Incoming line voltage is too high.

Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.

V3MH TCM

High Voltage Hose Incoming line voltage is too high.

Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.

V4CM MCM

High Voltage MCM Incoming line voltage is too high.

Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.

V4IT TCM

High Voltage CAN Bad 24 VDC power supply.

Check voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply.

V4MA TCM

High Voltage A Incoming line voltage is too high.

Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.

V4MB TCM

High Voltage B Incoming line voltage is too high.

Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.

V4MH TCM

High Voltage Hose Incoming line voltage is too high.

Ensure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC.

Page 34 of the Graco 333024F user manual — WXUU ADM
Page 34 · click to enlarge
Page 34

Error Location Type Description Cause Solution

WBC0 MCM

Incorrect software version.

Insert a system token into the ADM module and cycle the power. Wait until the upload is complete before removing the token.

MCM does not have line voltage.

If V1CM also exists, see troubleshooting for V1CM. The software version cannot be read if the MCM does not have line voltage.

WMI0 TCM

TCM Fan Error Fan inside TCM is not operating properly.

Check for debris in the TCM fan and clear with forced air if necessary.

WSUX USB

A valid configuration file can't be found for the USB.

Inset a system token into the ADM and cycle power. Wait until the lights on the USB port stop flashing before removing token.

WXUD ADM

USB Download Error Log download failed.

Backup and reformat the USB drive. Retry download.

WXUU ADM

USB Upload Error Custom language file failed to upload.

Perform normal USB download and use the new disptext.txt file to upload the custom language.

Software Version Error · Configuration Error USB

Page 35 of the Graco 333024F user manual — System
Page 35 · click to enlarge
Page 35

System

Before performing any troubleshooting procedures:

1. Relieve Pressure. See Pressure Relief Procedure, page 43 .
2. Turn main power switch OFF.
3. Allow equipment to cool.

Reactor ADM does not turn on.

No power. Turn main power switch ON.

Failed 24 V power supply. Replace power supply.

Failed surge protector. Replace surge protector.

Electric motor does not operate.

Loose connections. Check MCM connection 13.

Tripped circuit breaker (CB02). Reset breaker, see Repair Circuit Breaker Module, page 55. Check 240VAC at output of breaker.

Shorted windings. Replace motor, see Repair Electric Motor, page 54.

Electric motor runs erratically. Failed motor bearing. Replace motor, see Repair Electric Motor, page 54.

Problem Cause Solution

Page 36 of the Graco 333024F user manual — System
Page 36 · click to enlarge
Page 36

Cooling fans not working.

Loose wire. Check. See Electrical Schematics, page 91.

Fan blade obstructed. Remove obstruction.

Defective fan. Replace. See Replace Motor Fan, page 57.

Pump output low.

Obstructed fluid hose or gun; fluid hose ID too small.

Open, clear; use hose with larger ID.

Worn piston valve or intake valve in displacement pump.

See pump manual.

Pressure setpoint too high. Reduce setpoint and output will increase.

Fluid leak in pump packing nut area.

Worn throat seals. Replace. See pump manual.

No pressure on one side. Fluid leaking from heater inlet rupture disk (372).

Check if heater and PRESSURE RELIEF/SPRAY valve (SA or SB) are plugged. Clear. Replace rupture disk (372) with a new one; do not replace with a pipe plug.

Problem Cause Solution

Page 37 of the Graco 333024F user manual — Hose Heat System
Page 37 · click to enlarge
Page 37

Hose Heat System

Before performing any troubleshooting procedures:

1. Relieve Pressure. See Pressure Relief Procedure, page 43 .
2. Turn main power switch OFF.
3. Allow equipment to cool.

Hose heats but heats slower than usual or it does not reach temperature.

Ambient temperature is too cold. Relocate hoses to a warmer area or recirculate heated fluid through the hose.

FTS failed or not installed correctly. Check FTS, see Check RTD Cables and FTS, page 65.

Low supply voltage. Verify line voltage. Low line voltage significantly reduces power available to the hose heat system, affecting longer hose lengths.

Hose does not maintain temperature while spraying.

A and B setpoints too low. Increase A and B setpoints. Hose is designed to maintain temperature, not to increase it.

Ambient temperature is too cold. Increase A and B setpoints to increase fluid temperature and keep it steady.

Flow too high. Use smaller mix chamber. Decrease pressure.

Hose was not fully preheated. Wait for hose to heat to correct temperature before spraying.

Low supply voltage. Verify line voltage. Low line voltage significantly reduces power available to the hose heat system, affecting longer hose lengths.

Problem Cause Solution

Page 38 of the Graco 333024F user manual — Hose Heat System
Page 38 · click to enlarge
Page 38

Hose temperature exceeds setpoint.

A and/or B heaters are overheating material.

Check primary heaters for either a RTD problem or a failed element attached to RTD, see Electrical Schematics, page 91.

Faulty FTS connections. Verify that all FTS connections are snug and that pins of connectors are clean. Unplug and re-plug RTD wires, cleaning off any debris.

Ambient temperature is too high. Cover hoses or move to a location with a lower ambient temperature.

Missing or damaged insulation around FTS, causing the hose heat to be ON constantly.

Make sure the hose bundle has adequate insulation evenly covering the entire length and connection joints.

Problem Cause Solution

Page 39 of the Graco 333024F user manual — Hose Heat System
Page 39 · click to enlarge
Page 39

Erratic hose temperature.

Faulty FTS connections. Verify that all FTS connections are snug and that pins of connectors are clean. Unplug and re-plug FTS wires along length of hose, cleaning off any debris.

FTS not installed correctly. FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, see Repair Fluid Temperature Sensor (FTS), page 66.

Missing or damaged insulation around FTS, causing the hose heat to be ON constantly.

Make sure the hose bundle has adequate insulation evenly covering the entire length and connection joints.

Hose does not heat.

FTS failed. Check FTS, see Repair Fluid Temperature Sensor (FTS), page 66.

FTS not installed correctly. FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, see Repair Fluid Temperature Sensor (FTS), page 66.

Loose hose electrical connections. Check connections. Repair as necessary.

Circuit breakers tripped. Reset breakers (CB01 ), see Repair Circuit Breaker Module, page 55.

Hose zone not turned on. Turn on hose heat zone.

A and B temperature setpoints too low.

Check. Increase if necessary.

Problem Cause Solution

Page 40 of the Graco 333024F user manual — Hose Heat System
Page 40 · click to enlarge
Page 40

Hoses near Reactor are warm, but hoses downstream are cold.

Shorted connection or failed hose heating element.

With power off, check the hose resistance with and without the whip hose attached. With the whip hose attached, the reading should be less than 3 ohm. With- out the whip hose attached, the reading should be OL (open loop). See Check Hose Heat Power Connectors, page 64.

Low hose heat.

A and B temperature setpoints too low.

Increase A and B setpoints. Hose designed to maintain temperature, not increase temperature.

Hose temperature setpoint too low.

Check. Increase if necessary to maintain heat.

Flow too high. Use smaller mix chamber. Decrease pressure.

Low current; FTS not installed. Install FTS, see operation manual.

Hose heat zone not turned on long enough to reach setpoint.

Allow hose to heat up, or preheat fluid.

Loose hose electrical connections. Check connections. Repair as necessary.

Ambient temperature is to low Relocate hoses to a warmer area or increase A and B setpoints.

Problem Cause Solution

Page 41 of the Graco 333024F user manual — Primary Heater
Page 41 · click to enlarge
Page 41

Primary Heater

Before performing any troubleshooting procedures:

1. Relieve Pressure. See Pressure Relief Procedure, page 43 .
2. Turn main power switch OFF.
3. Allow equipment to cool.

Try the recommended solutions in the order given for each problem, to avoid unnecessary repairs. Also, determine that all circuit breakers, switches, and controls are properly set and wiring is correct before assuming there is a problem.

Primary Heater(s) does not heat.

Heat turned off. Turn on heat zones.

Temperature control alarm. Check ADM for error codes.

Signal failure from RTD. Signal failure from RTD.

Control of primary heat is abnormal; high temperature overshoots (T4DA, T4DB) occurs intermittently.

Dirty RTD connections. Examine RTD cables connected to TCMs. Confirm RTDs are not plugged into opposite heat zone. Unplug and re-plug RTD connectors. Unplug and re-plug RTD connectors. Ensure RTD tip contacts the heater element.

RTD not contacting heater element.

Loosen ferrule nut, push in RTD so tip contacts heater element. Holding RTD tip against heater element, tighten ferrule nut 1/4 turn past tight.

Failed heater element. See Replace Heater Element, page 60.

Signal failure from RTD. See (T6DA, T6DB), Error Codes.

Problems · Problem Cause Solution

Page 42 of the Graco 333024F user manual — Graco InSite
Page 42 · click to enlarge
Page 42

Graco InSite

Problem Cause Solution Turn Reactor ON. Ensure unit is properly installed.

No module status LEDs are illuminated.

No power to cellular module.

Verify 24V at output of the power supply.

Make sure the M8, 4–pin to M12, 8–pin cable is installed between cellular module and power supply. Still identifying location. Wait a few minutes for the unit to identify the location. Move system to a location with a clear view of the sky.

Has not identified GPS location (green module status LED flashing). Unable to identify location. In a location where GPS lock cannot occur. Buildings and warehouses often prevent GPS locks.

Use extension cable 16X521 and move cellular module to a location with a clear view of the sky. Still establishing cellular connection.

Has not established cellular connection (orange module status LED flashing). Unable to establish cellular connection.

Wait a few minutes for the unit to establish the connection. Move system to a location with cellular service to establish cellular connection.

Use extension cable 16X521 and move cellular module to a location with a clear view of the sky. Cannot view data for my unit(s) on website.

Activate unit. See Registering and Activating the Graco InSite section. Temperature data not displayed on website.

Graco InSite unit has not been activated.

See System troubleshooting section. Hose zone temperature data not displayed on website.

Reactor temperature measurement is not working.

The RTD or thermocouple is not correctly installed on the hose or is broken.

See RTD or Thermocouple repair section.

Pressure data not displayed on website.

Reactor pressure measurement is not working.

See System troubleshooting section.

Page 43 of the Graco 333024F user manual — Pressure Relief Procedure
Page 43 · click to enlarge
Page 43

Pressure Relief Procedure

4. Route fluid to waste containers or supply tanks. Turn PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE RELIEF/CIRCULATION

Follow the Pressure Relief Procedure whenever you see this symbol.

. Ensure gauges drop to 0.

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing equipment.

5. Engage gun piston safety lock.
Graco 333024F — Pressure Relief Procedure diagram (page 43)
Fig. 5 · Pressure Relief Procedure

The Fusion AP gun is shown.

1. Relieve pressure in gun and perform gun shutdown procedure. See gun manual.
6. Disconnect gun air line and remove gun fluid manifold.
2. Close gun fluid inlet valves A and B.
Graco 333024F — Pressure Relief Procedure diagram (page 43)
Fig. 6 · Pressure Relief Procedure
Graco 333024F — Pressure Relief Procedure diagram (page 43)
Fig. 7 · Pressure Relief Procedure
3. Shut off feed pumps and agitator, if used.

Pressure Relief Procedure

Page 44 of the Graco 333024F user manual — NOTICE
Page 44 · click to enlarge
Page 44

Shutdown

4. Press

to park the Component A Pump. The park operation is complete when green dot goes out. Verify the park operation is complete before moving to next step.

Graco 333024F — Shutdown diagram (page 44)
Fig. 8 · Shutdown

Shutdown system to avoid electric shock. All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing equipment.

5. Press

to deactivate the system.

Graco 333024F — Shutdown diagram (page 44)
Fig. 9 · Shutdown

NOTICE

Proper system setup, startup, and shutdown procedures are critical to electrical equipment reliability. The following procedures ensure steady voltage. Failure to follow these procedures will cause voltage fluctuations that can damage electrical equipment and void the warranty.

6. Turn off the air compressor, air dryer, and breathing air.
Graco 333024F — NOTICE diagram (page 44)
Fig. 10
1. Press

to stop the pumps.

7. Turn main power switch OFF.
2. Turn off all heat zones.
Graco 333024F — NOTICE diagram (page 44)
Fig. 11
3. Relieve pressure. See Pressure Relief Procedure, page 43 .

To prevent electric shock do not remove any shrouds or open the electrical enclosure door.

Graco 333024F — NOTICE diagram (page 44)
Fig. 12

Shutdown

Page 45 of the Graco 333024F user manual — Shutdown
Page 45 · click to enlarge
Page 45
Graco 333024F — Shutdown diagram (page 45)
Fig. 13 · Shutdown
8. Close all fluid supply valves. 9. Engage gun piston safety lock then close fluid inlet valves A and B.

Shutdown · Fusion Probler

Page 46 of the Graco 333024F user manual — RELIEF/CIRCULATION
Page 46 · click to enlarge
Page 46

Flushing

To flush feed hoses, pumps, and heaters separately from heated hoses, set PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE

RELIEF/CIRCULATION

. Flush through bleed lines (N).

To avoid fire and explosion:

  • Flush equipment only in a well-ventilated area.
  • Do not turn on heaters until fluid lines are clear of solvent.
  • Flush out old fluid with new fluid, or flush out old fluid with a compatible solvent before introducing new fluid.

To flush entire system, circulate through gun fluid manifold (with manifold removed from gun).

  • Use the lowest possible pressure when flushing.
  • All wetted parts are compatible with common solvents. Use only moisture-free solvents.

To prevent moisture from reacting with isocyanate, always leave the system filled with a moisture-free plasticizer or oil. Do not use water. Never leave the system dry. See Important Isocyanate Information.

Flushing

Page 47 of the Graco 333024F user manual — Flush Inlet Strainer Screen
Page 47 · click to enlarge
Page 47

Repair

1. Close the fluid inlet valve on the y-strainer inlet and shut off the appropriate feed pump. This prevents material from being pumped while cleaning the screen.
Graco 333024F — Repair diagram (page 47)
Fig. 14 · Repair
2. Place a container under the strainer base to catch drain off when removing the strainer plug (C).

Repairing this equipment requires access to parts that may cause electric shock or other serious injury if work is not performed properly. Be sure to shut off all power to equipment before repairing.

3. Remove the screen (A) from the strainer manifold. Thoroughly flush the screen with compatible solvent and shake it dry. Inspect the screen. No more than 25% of the mesh should be restricted. If more than 25% of the mesh is blocked, replace the screen. Inspect the o—ring (B) and replace as required.

Before Beginning Repair

Graco 333024F — Before Beginning Repair diagram (page 47)
Fig. 15 · Before Beginning Repair
4. Ensure the pipe plug (D) is screwed into the strainer plug (C). Install the strainer plug with the screen (A) and o—ring (B) in place and tighten. Do not overtighten. Let the gasket make the seal.

Proper system setup, startup, and shutdown procedures are critical to electrical equipment reliability. The following procedures ensure steady voltage. Failure to follow these procedures will cause voltage fluctuations that can damage electrical equipment and void the warranty.

5. Open the fluid inlet valve, ensure that there are no leaks, and wipe the equipment clean. Proceed with operation.
Graco 333024F — Before Beginning Repair diagram (page 47)
Fig. 16 · Before Beginning Repair
1. Flush if necessary. See Flushing, page 46 .
2. See Shutdown, page 44 .

Flush Inlet Strainer Screen

The inlet strainers filter out particles that can plug the pump inlet check valves. Inspect the screens daily as part of the startup routine, and clean as required.

Isocyanate can crystallize from moisture contamination or from freezing. If the chemicals used are clean and proper storage, transfer, and operating procedures are followed, there should be minimal contamination of the A-side screen.

Clean the A-side screen only during daily startup. This minimizes moisture contamination by immediately flushing out any isocyanate residue at the start of dispensing operations.

Repair

Page 48 of the Graco 333024F user manual — Change Pump Lubricant
Page 48 · click to enlarge
Page 48
Graco 333024F — Change Pump Lubricant diagram (page 48)
Fig. 17 · Change Pump Lubricant

Change Pump Lubricant

4. When the reservoir is flushed clean, fill with fresh lubricant.

Check the condition of the ISO pump lubricant daily. Change the lubricant if it becomes a gel, its color darkens, or it becomes diluted with isocyanate.

5. Thread the reservoir onto the cap assembly and place it in the bracket.
6. The lubrication system is ready for operation. No priming is required.

Gel formation is due to moisture absorption by the pump lubricant. The interval between changes depends on the environment in which the equipment is operating. The pump lubrication system minimizes exposure to moisture, but some contamination is still possible.

Lubricant discoloration is due to continual seepage of small amounts of isocyanate past the pump packings during operation. If the packings are operating properly, lubricant replacement due to discoloration should not be necessary more often than every 3 or 4 weeks.

To change pump lubricant:

1. Follow Pressure Relief Procedure, page 43 .
2. Lift the lubricant reservoir (R) out of the bracket and remove the container from the cap. Holding the cap over a suitable container, remove the check valve and allow the lubricant to drain. Reattach the check valve to the inlet hose.

Pump Lubrication System Figure 2

3. Drain the reservoir and flush it with clean lubricant.

Repair

Page 49 of the Graco 333024F user manual — Remove Pump
Page 49 · click to enlarge
Page 49
Graco 333024F — Remove Pump diagram (page 49)
Fig. 18 · Remove Pump

Pump rod and connecting rod move during operation. Moving parts can cause serious injury such as pinching or amputation. Keep hands and fingers away from connecting rod during operation.

8. Route fluid to waste containers or supply tanks. Turn PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE RELIEF/CIRCULATION
7. Shut off both feed pumps. Close all fluid supply valves.
Page 50 of the Graco 333024F user manual — Install Pump
Page 50 · click to enlarge
Page 50
Graco 333024F — Install Pump diagram (page 50)
Fig. 19 · Install Pump

Use drop cloth or rags to protect Reactor and surrounding areas from spills.

Steps 9–11 apply to pump A. To disconnect pump B, go to steps 12 and 13.

9. Disconnect fittings at fluid inlet (C) and outlet (D). Also disconnect steel outlet tube from heater inlet.
Graco 333024F — Install Pump diagram (page 50)
Fig. 20 · Install Pump
10. Disconnect tubes (T). Remove both tube fittings (U) from wet-cup.
11. Loosen locknut (G) by hitting firmly with a non-sparking hammer. Unscrew pump far enough to expose rod retaining pin. Push retaining wire clip up. Push pin out. Continue unscrewing pump.

3 Pump top threads must be nearly flush with bearing face (N).

Install Pump

Steps 1–5 apply to pump B. To reconnect pump A, proceed to step 6.

1. Ensure locknut (G) is screwed on pump with flat side up. Screw pump into bearing housing (M) until pin holes align. Push pin (F) in. Pull retaining wire clip (E) down. See Fig. 4 for view and assembly notes.
2. Continue screwing pump into housing until fluid outlet (D) is aligned with steel tube and top threads are +/- 1/16 in. (2 mm) of bearing face (N).
3. Tighten locknut (G) by hitting firmly with a non-sparking hammer.

3 Pump top threads must be nearly flush with bearing face (N).

4. Reconnect fluid inlet (C) and outlet (D).
5. Go to step 13.

Steps 12 and 13 apply to pump B.

12. Disconnect fluid inlet (C) and outlet (D). Also disconnect steel outlet tube from heater inlet.

Steps 6–12 apply to pump A only.

13. Push retaining wire clip (E) up. Push pin (F) out. Loosen locknut (G) by hitting firmly with a non-sparking hammer. Unscrew pump.
6. Ensure star-shaped locknut (G) is screwed on pump with flat side up. Carefully twist and extend displacement rod 2 in. (51 mm) above wet-cup.

Repair

Page 51 of the Graco 333024F user manual — Repair Drive Housing
Page 51 · click to enlarge
Page 51
Graco 333024F — Repair Drive Housing diagram (page 51)
Fig. 21 · Repair Drive Housing
11. Apply thin film of TSL to barbed fittings. Using two hands, support tubes (T) while pushing straight onto barbed fittings. Secure each tube with a wire tie between two barbs.

Do not let tubes kink or buckle.

12. Reconnect fluid inlet (C).
13. Purge air and prime the system. See Reactor operation manual.

Repair Drive Housing

1. Press

to stop the pumps.

2. Turn off heat zones.
7. Start threading pump into bearing housing (M). When pin holes align, insert pin. Pull retaining wire clip down.
3. Flush pump.
4. Press

to park the pumps in the down position.

8. Continue threading pump into bearing housing (M) until top threads are +/- 1/16 in. (2 mm) of bearing face (N). Ensure that barbed fittings at wet-cup flush ports are accessible.
5. Press

to deactivate the system.

6. Turn main power switch off.
9. Connect component A outlet tube loosely at pump and at heater. Line up tube, then tighten fittings securely.
10. Tighten star-shaped locknut (G) by hitting firmly with a non-sparking hammer.

Repair · Removal

Page 52 of the Graco 333024F user manual — Repair Drive Housing
Page 52 · click to enlarge
Page 52
Graco 333024F — Repair Drive Housing diagram (page 52)
Fig. 22 · Repair Drive Housing
7. Perform Pressure Relief Procedure, page 43 .
8. Remove the system frame from the floor and L-brackets.

Do not drop gear cluster (104) when removing drive housing (102). Gear cluster may stay engaged in motor front end bell or drive housing.

Graco 333024F — Repair Drive Housing diagram (page 52)
Fig. 23 · Repair Drive Housing
14. Remove screws (112, 119) and washers (114) and pull drive housing (102) off motor (101).

The A side drive housing includes cycle counter switch (121). If replacing this housing, remove screws (122) and switch. Reinstall screws and switch on new drive housing.

Graco 333024F — Repair Drive Housing diagram (page 52)
Fig. 24 · Repair Drive Housing
9. Remove two bolts and nuts and fold the electrical enclosure backward.
10. Remove screws (21) and motor shroud (11). Rest the motor shroud behind the motor without straining the fan power cable.

Examine bearing housing (103) and connecting rod (105). If these parts need replacing, first remove the pump (106), see Remove Pump, page 49.

11. Remove cover (60) and screws (21).
12. Remove cycle counter (121) from housing by removing screw (122).
13. Disconnect pump inlet and outlet lines. Remove screws (113), washers (115), and bearing housing (103).

Repair

Page 53 of the Graco 333024F user manual — Installation
Page 53 · click to enlarge
Page 53
4. Push drive housing (102) onto motor (101). Install screws (112) and washers (114).
1. Apply heavy duty extreme pressure grease liberally to washers (107, 108, 118), all gears, and inside drive housing (102).

If bearing housing (103), connecting rod (105), or pump (106) were removed, reassemble rod in housing and install pump, see Install Pump, page 50 .

2. Install one bronze washer (108) in drive housing, then install steel washers (107, 118) as shown.
3. Install second bronze washer (108) on gear cluster (104) and insert gear cluster in drive housing.
5. Route cycle counter switch cable (121) around the motor fan and reattach to housing (102) with screws (122).
6. Install bearing housing (103), screws (113), and washers (114). Pumps must be in phase (both at same position in stroke).

Drive housing crankshaft must be in line with crankshaft at other end of motor.

7. Install cover (60) and screws (21).
8. Install motor shield (11) and screws (21).
Graco 333024F — Installation diagram (page 53)
Fig. 25 · Installation

Repair · Installation

Page 54 of the Graco 333024F user manual — NOTICE
Page 54 · click to enlarge
Page 54

Repair Electric Motor

Graco 333024F — Repair Electric Motor diagram (page 54)
Fig. 26 · Repair Electric Motor

NOTICE

Be careful not to drop or damage the motor. The motor is heavy and may require two people to lift.

1. Remove the system frame from the floor and L-brackets.
Graco 333024F — NOTICE diagram (page 54)
Fig. 27
1. Place motor on unit. Thread motor cables into conduit as before. See Electrical Schematics, page 91 .
2. Fasten motor with screws (25) until screws are fully threaded in frame. Do not tighten screws until drive housing and pumps are connected to the motor.
2. Remove drive housing and pump assemblies. See Repair Drive Housing, page 51 .
3. Disconnect electric motor (101) power cable from port #15 on the MCM. Remove connector by loosening four terminal screws.
3. Install drive housing and pump assemblies, see Installation, page 53 .
4. Route motor (101) power cord from motor through conduit and connect to port #15 on MCM. Route over temperature cable up from motor and connect to port #2 on MCM. Insert cables in conduit and use tie wraps to secure the conduit together.
4. Remove motor shroud (11). Rest the motor shroud assembly behind the motor without straining the fan power cable.
5. Disconnect over temperature cable from port #2 on MCM. Cut tie wraps around harness to remove cable.
5. Connect motor shroud assembly to motor (101).
6. Remove four screws (25) holding motor (101) to bracket. Lift motor off unit.
6. Install drive housing covers and motor cover.
7. Return to service.

Repair · Removal · Installation

Page 55 of the Graco 333024F user manual — Repair Circuit Breaker Module
Page 55 · click to enlarge
Page 55

Repair Circuit Breaker Module

new circuit breaker. Insert wires and tighten down all screws.

Graco 333024F — Repair Circuit Breaker Module diagram (page 55)
Fig. 28 · Repair Circuit Breaker Module
1. See Before Beginning Repair, page 47 .
2. Using an ohmmeter, check for continuity across circuit breaker (top to bottom). If no continuity, trip breaker, reset, and retest. If still no continuity, replace breaker as follows:

Figure 8 Circuit Breakers

a. Refer to Electrical Schematics, page 91, and circuit breaker table.

Graco 333024F — Repair Circuit Breaker Module diagram (page 55)
Fig. 29 · Repair Circuit Breaker Module

b. Follow Shutdown instructions. See Shutdown, page 44.

c. Refer to circuit breaker identification table and electrical diagrams in Reactor repair manual.

d. Loosen two screws connecting wires and bus bar to circuit breaker that will be replaced. Disconnect wires.

e. Pull locking tab out 1/4 in. (6mm) and pull circuit breaker away from the din rail. Install

Repair

Page 56 of the Graco 333024F user manual — NOTICE
Page 56 · click to enlarge
Page 56

Replace Fluid Inlet Sensor

5. Replace sensor (602).

Replace Pressure Transducers

For Elite models only.

1. Perform Shutdown, page 44 .
1. Perform Shutdown, page 44 .
2. Perform Pressure Relief Procedure, page 43 .
2. Perform Pressure Relief Procedure, page 43 .
3. Disconnect transducer cables (405) from #6 and #7 connectors on the MCM.
3. Disconnect inlet sensor cable from the fluid inlet assembly. Inspect cable for damage and replace if necessary. See Electrical Schematics, page 91 .
4. Remove wire ties constraining transducer cable and remove cable from cabinet.
Graco 333024F — Replace Pressure Transducers diagram (page 56)
Fig. 30 · Replace Pressure Transducers
5. Install o-ring (416) on new transducer (405).
6. Install transducer in manifold. Mark end of cable with tape (red=transducer A, blue=transducer B).
7. Route new cable into cabinet and thread into bundle as before. Attach cable ties to bundle as before.
8. Connect A side pressure transducer cable to MCM port #6. Connect B side pressure transducer cable to MCM port #7.
Graco 333024F — Replace Pressure Transducers diagram (page 56)
Fig. 31 · Replace Pressure Transducers

Figure 9 Fluid Inlet Sensor

4. To replace sensor cable:

a. Open wire bundle and remove sensor cable.

b. Cut any wire ties and disconnect from MCM. See Electrical Schematics, page 91.

NOTICE

To prevent damage to cable, route and secure cable in wire bundle with wire ties.

Repair

Page 57 of the Graco 333024F user manual — Replace Fans
Page 57 · click to enlarge
Page 57

Replace Fans

Graco 333024F — Replace Fans diagram (page 57)
Fig. 32 · Replace Fans
Graco 333024F — Replace Fans diagram (page 57)
Fig. 33 · Replace Fans

Shutdown system to avoid electric shock. To avoid burns, do not perform maintenance on the fan until the system has reached ambient temperature.

1. Perform Shutdown, page 44 .
2. Open cabinet door and disconnect fan cables from terminal blocks. See Electrical Schematics, page 91 .
3. Remove four screws (21) from motor cover (11). If necessary, fold frame (1) to remove motor cover (10). See Repair Drive Housing, page 51 , steps 1–10.
4. Cut tie wraps to remove cable.
5. Remove nuts (39), screws (22), washers (34) and fan (32). Install new fan in reverse order.

Ensure fan (32) blows onto motor.

Replace Electrical Enclosure Fan

1. Perform
2. Open electrical enclosure door (401). Loosen four nuts (421) and remove fan (404).
3. Install new fan (404) in reverse order of disassembly so that the fan blows out of the electrical enclosure.

Repair · Replace Motor Fan

Page 58 of the Graco 333024F user manual — Replace Fans
Page 58 · click to enlarge
Page 58
Graco 333024F — Replace Fans diagram (page 58)
Fig. 34 · Replace Fans

Repair

Page 59 of the Graco 333024F user manual — Replace Transformer Fan
Page 59 · click to enlarge
Page 59
4. Disconnect fan and transformer connections from terminal blocks. Connections are on left side labeled: V+, V-, 1, 2, 3, and 4.
Graco 333024F — Replace Transformer Fan diagram (page 59)
Fig. 35 · Replace Transformer Fan
5. Remove four nuts (27) holding metal transformer cover (8) to frame. Carefully remove cover while sliding wires through hole in cover.
6. Remove four screws (23), washers (29), and fan (32).
3. Remove bolt (20) on top of the heater junction box (48).

Repair · Replace Transformer Fan

Page 60 of the Graco 333024F user manual — Repair Primary Heater
Page 60 · click to enlarge
Page 60

Repair Primary Heater

8. Wait for heater to cool.
9. Remove four bolts (23) and shroud (10).
Graco 333024F — Repair Primary Heater diagram (page 60)
Fig. 36 · Repair Primary Heater
1. Press

to stop the pumps.

2. Turn off heat zones.
3. Flush pump.
4. Press

to park the pumps in the down position. The park operation is complete when green dot goes out. Verify the park operation is complete before moving to next step.

10. Remove screw (20) and lower din rail cover (48).
11. Disconnect heater wires:

a. A Side: Disconnect A side heater wires, transformer, and transformer fan wires from lower din rail (33).

b. B Side: Disconnect B side heater wires and remove lower din rail (33) from B side heater (5).

12. Test heater wires with ohmmeter.
5. Press

to deactivate the system.

Graco 333024F — Repair Primary Heater diagram (page 60)
Fig. 37 · Repair Primary Heater
6. Turn main power switch off.
7. Relieve pressure. See Pressure Relief Procedure, page 43 .

To prevent a short circuit or lowering the transformer life, do not splash fluid on transformer. Cover transformer with a plastic sheet or piece of cardboard.

Repair · Replace Heater Element

Page 61 of the Graco 333024F user manual — Repair Primary Heater
Page 61 · click to enlarge
Page 61
13. Remove nuts (27) and transformer cover (8). Cover transformer with plastic sheet or cardboard.

burnt, ash-like material adhered to element, or sheath shows pitting marks.

20. Install new heater element (208), holding mixer (210) so it does not block RTD port.
14. Disconnect overtemperature switches (209) from cable.
21. Secure heater to frame with bolts (23).
15. Loosen ferrule nut (N). Remove RTD (212) from heater housing. Do not remove adapter (206) unless necessary. If adapter must be removed, ensure that mixer (210) is out of the way when replacing adapter.
22. Reinstall RTD (212), Repair Primary Heater, page 60 .
23. Reconnect cable to overtemperature switches (209).
16. Disconnect inlet and outlet fluid tubes from heater.
24. Reconnect wires to lower din rail. If necessary, install lower din rail (33).
17. Remove two bolts (23) and lift heater over transformer.
25. Install lower din rail cover (48).
18. Place heater block (201) in a vise. Use a wrench to remove heater element (208).

The heater outputs its rated wattage at 240 VAC. Low line voltage will reduce power available and the heater will not perform at full capacity.

19. Inspect element. It should be relatively smooth and shiny. Replace element if there is a crusted,
Graco 333024F — Repair Primary Heater diagram (page 61)
Fig. 38 · Repair Primary Heater

Repair · Line Voltage

Page 62 of the Graco 333024F user manual — Repair Overtemperature Switch
Page 62 · click to enlarge
Page 62

110009, install new switch in same location on housing (201), and secure with screws (213). Reconnect cables.

Graco 333024F — Repair Overtemperature Switch diagram (page 62)
Fig. 39 · Repair Overtemperature Switch
1. Perform Shutdown, page 44 .
2. Wait for heaters to cool.
3. Remove heater cover (10).
4. Disconnect overtemperature switches (209) from cable (46). Test across spade terminals with ohmmeter.

a. If the resistance is not approximately 0 ohms, the overtemperature switch needs to be replaced. Go to step 5.

b. If the resistance is approximately 0 ohms, inspect cable (46) to ensure it is not cut or open. Reconnect the overtemperature switch (209) and cable (46). Disconnect cable from TCM. Test from pin 1 to 3 and 1 to 4. If resistance is not approximately 0, and switches are 0. Replace cable in place of original cable.

5. If switch fails test, remove screws. Discard failed switch. Apply a thin layer of thermal compound

Repair · Repair Overtemperature Switch

Page 63 of the Graco 333024F user manual — Replace RTD
Page 63 · click to enlarge
Page 63

a. Apply PTFE tape and thread sealant to male pipe threads and tighten RTD housing (H) into adapter (206).

1. Perform Shutdown, page 44 .
2. Wait for heater to cool.

b. Push in RTD (212) so tip contacts heater element (208).

3. Remove heater cover (10).

c. Holding RTD (212) against heater element, tighten ferrule nut (N) 3/4 turn past finger-tight.

4. Cut cable ties around the woven wrap with the RTD cable (212).
5. Disconnect RTD cable(212) from TCM (453).
9. Route wires (S) as before through woven wrap and reconnect RTD cable (212) to the TCM.
6. Loosen ferrule nut (N). Remove RTD (212) from heater housing (201), then remove RTD housing (H). Do not remove the adapter (206) unless necessary. If adapter must be removed, ensure that mixer (210) is out of the way when replacing the adapter.
10. Replace heater shroud (10).
11. Follow startup instructions in the operation manual. Turn on A and B heat simultaneously to test. Temperatures should rise at same rate. If one is low, loosen ferrule nut (N) and tighten RTD housing (H) to ensure RTD tip contacts element (212) when ferrule nut (N) is retightened.
7. Remove RTD cable (212) from woven wrap.
8. Replace RTD (212).
Graco 333024F — Replace RTD diagram (page 63)
Fig. 40 · Replace RTD

Repair · Replace RTD

Page 64 of the Graco 333024F user manual — Repair Heated Hose
Page 64 · click to enlarge
Page 64

Repair Heated Hose

3. For Series A only: Disconnect hose connector (D) at Reactor.

Refer to the heated hose manual 309572 for hose replacement parts.

Graco 333024F — Repair Heated Hose diagram (page 64)
Fig. 41 · Repair Heated Hose

Check Hose Heat Power Connectors

1. Perform Shutdown, page 44 .

Whip hose must be connected.

2. Disconnect power harness (PM) from hose termination box terminal block (TB).
Graco 333024F — Repair Heated Hose diagram (page 64)
Fig. 42 · Repair Heated Hose
4. Using an ohmmeter, check between the connectors (D). There should be continuity.
5. If hose fails test, retest at each length of hose, including whip hose, until failure is isolated.

Repair

Page 65 of the Graco 333024F user manual — Check RTD Cables and FTS
Page 65 · click to enlarge
Page 65

Check RTD Cables and FTS

Graco 333024F — Check RTD Cables and FTS diagram (page 65)
Fig. 43 · Check RTD Cables and FTS
1. Perform Shutdown, page 44 .
2. Disconnect RTD cable (C) at Reactor.
3. Test with an ohmmeter between pins of cable connector C.

Do not touch outer ring with test probe.

Graco 333024F — Check RTD Cables and FTS diagram (page 65)
Fig. 44 · Check RTD Cables and FTS

Heated Hose Figure 17

To assist in taking readings, order RTD Test Kit 24N365. Kit includes two cables: one cable with a compatible female M8 connector and another cable with a male M8 connector. Both cables have stripped wire at the other end for easy test probe access.

4. Retest at each length of hose, including whip hose, until failure is located.
5. If the FTS is not reading properly at the end of the hose, connect FTS directly to RTD cable (C) at the manifold.
Graco 333024F — Check RTD Cables and FTS diagram (page 65)
Fig. 45 · Check RTD Cables and FTS

3 to 1 / brown to blue approximately 1090 ohms

6. If the FTS reads properly at the manifold but not at the end of the hose, check cable (C) connections. Verify they are tight.

3 to 4 / blue to black approximately 1090 ohms

1 to 4 / brown to black 0.2 - 0.4 ohms

Repair

Page 66 of the Graco 333024F user manual — Repair Fluid Temperature Sensor (FTS)
Page 66 · click to enlarge
Page 66

Repair Fluid Temperature Sensor (FTS)

The Fluid Temperature Sensor (FTS) is supplied with the system. Install FTS between main hose and whip hose. See Heated Hose manual 309572 for instructions.

Graco 333024F — Repair Fluid Temperature Sensor (FTS) diagram (page 66)
Fig. 46 · Repair Fluid Temperature Sensor (FTS)

a. Disconnect air hoses (C,L) and electrical connectors (D).

b. Disconnect FTS from whip hose (W) and fluid hoses (A, B).

1. Perform Shutdown, page 44 .
2. Remove tape and protective covering from FTS. Disconnect hose cable (F).

c. Remove ground wire (K) from ground screw on underside of FTS.

3. If FTS is not reading properly at the end of the hose, see Check RTD Cables and FTS, page 65 .

d. Remove FTS probe (H) from component A (ISO) side of hose.

4. If FTS fails, replace FTS.

Repair · Installation · Test/Removal

Page 67 of the Graco 333024F user manual — Transformer Primary Check
Page 67 · click to enlarge
Page 67

indicator on the circuit breaker GREEN. Use an ohmmeter to test for continuity between two transformer wires in terminal blocks TB17 and TB18; there should be continuity.

See Electrical Schematics, page 91.

1. Check wires and transformer:

a. See Shutdown, page 44.

c. Close the circuit breaker CB01.

b. Shut off CB05.

c. Use an ohmmeter to test for continuity between terminals 2 and 4 of CB05. If there is no continuity, check transformer.

2. Check transformer:

a. See Shutdown, page 44.

b. Remove lower shroud.

d. Apply incoming power to system.

c. Locate the two smaller (10 AWG) wires, labeled 1 and 2, coming out of transformer. Trace these wires back to terminal blocks TB15 and TB16.

e. To verify voltage on the secondary leads of the transformer, measure between the terminals terminals 3 and 4 on TB17 and TB18. Verify voltage is approximately 90 VAC for 240 VAC input.

d. Use an ohmmeter to test for continuity between two wires; there should be continuity.

f. See the Diagnostic Run Screen on the ADM. The Diagnostic Run Screen displays the incoming (90 Vac) to the TCM “Hose Voltage”. The diagnostic screen will show if the circuit breaker has been tripped for the incoming power to the TCM.

See Electrical Schematics, page 91.

1. Check wires and transformer:

a. Disconnect 7 pin green connector from TCM.

Graco 333024F — Transformer Primary Check diagram (page 67)
Fig. 47 · Transformer Primary Check

b. Use an ohmmeter to test for continuity between terminals 6 and 7 on the TCM 7 pin green connector. There should be continuity. If there is no continuity, check transformer.

c. Reconnect 7 pin green connector to TCM

2. Check transformer:

a. Remove lower shroud.

b. Locate the two larger (6 AWG) wires, labeled 3 and 4, coming out of transformer. Trace these wires back to TB17 and TB18. Open circuit breaker CB01 to turn the color

Repair · Transformer Primary Check · Transformer Secondary Check

Page 68 of the Graco 333024F user manual — Replace Transformer
Page 68 · click to enlarge
Page 68
1. Perform Shutdown, page 44 .
2. Remove four bolts (23) and shroud (10).
3. Remove lower dinrail cover (48).
4. Disconnect fan and transformer connections from terminal blocks. Connections are on left side labeled: V+, V-, 1, 2, 3, and 4.
5. Remove four nuts (27) holding metal transformer cover (8) to frame. Carefully remove cover while sliding wires through hole in cover.
Graco 333024F — Replace Transformer diagram (page 68)
Fig. 48 · Replace Transformer

Repair · Replace Transformer

Page 69 of the Graco 333024F user manual — Replace Power Supply
Page 69 · click to enlarge
Page 69
Graco 333024F — Replace Power Supply diagram (page 69)
Fig. 49 · Replace Power Supply
2. Disconnect input and output cables from both sides of the power supply. See Electrical Schematics, page 91 .
3. Insert a flat head screw driver in the mounting tab on the bottom of the power supply to remove from the din rail.
4. Install new power supply (535) in reverse order.
1. Loosen four screws (70) on inside of electrical enclosure door (61). Lift up and pull out to remove ADM (88).
3. Inspect ADM (88) for damage. Replace if necessary.
1. Loosen connections on terminals 1 and 3 on CB02.
2. Loosen connections on input to power supply (535) on N and L connections.
3. Remove two screws (413) and surge protector (505) from enclosure.
4. Install new surge protector (505) in reverse order.

Wire on both the circuit breaker and power supply are interchangeable.

Page 70 of the Graco 333024F user manual — Software Update Procedure
Page 70 · click to enlarge
Page 70

Replace Motor Control Module (MCM)

Replace Temperature Control Module (TCM)

1. Perform Shutdown, page 44 .
1. Perform Shutdown, page 44 .
2. Disconnect connectors from MCM (63). Disconnect two power cables. See Electrical Schematics, page 91 .
2. Open electrical enclosure door (61).
3. Disconnect all connectors from the TCM (453).
3. Remove nuts (91) and MCM (63).
4. Remove four nuts (461) and TCM (453).
4. Set rotary switch. 2= E–30 and 3= E-XP2.
5. Install new TCM module (453). Reassemble parts in reverse order.
5. Replace MCM in enclosure.
6. Connect cables to MCM. See Electrical Schematics, page 91 .
Graco 333024F — Replace Motor Control Module (MCM) diagram (page 70)
Fig. 50 · Replace Motor Control Module (MCM)
Graco 333024F — Replace Motor Control Module (MCM) diagram (page 70)
Fig. 51 · Replace Motor Control Module (MCM)

Figure 25 Replace TCM

Figure 24 Replace MCM

Software Update Procedure

Graco 333024F — Software Update Procedure diagram (page 70)
Fig. 52 · Software Update Procedure

Repair kit GCA modules are shipped pre-programmed and software loading is not necessary. If software version upgrade is necessary, follow the procedure in the manual provided.

Repair

Page 71 of the Graco 333024F user manual — Proportioners
Page 71 · click to enlarge
Page 71

Parts

Proportioners

Graco 333024F — Proportioners diagram (page 71)
Fig. 53 · Proportioners

Parts

Page 72 of the Graco 333024F user manual — Parts
Page 72 · click to enlarge
Page 72
Graco 333024F — Parts diagram (page 72)
Fig. 54 · Parts

1 Apply anaerobic polyacrylate pipe sealant to all non-swiveling pipe threads.

2 Apply grease to tube fitting threads. Torque to 43 ft-lbs (58 N•m).

3 Safety and warning labels are from label sheet (68).

Parts

Page 73 of the Graco 333024F user manual — Parts
Page 73 · click to enlarge
Page 73
Graco 333024F — Parts diagram (page 73)
Fig. 55 · Parts
1. - - FRAME 1
2. - - ENCLOSURE, electrical; see Electrical Enclosure, page 84

4 16X531 BRACKET, tsl, bottle 1

24U843 HEATER, 10kw, 2 zone, RTD; see Fluid Heater, page 80

24U842 HEATER, 7.5kw, 1 zone, RTD; see Fluid Heater, page 80

6 24U704 MANIFOLD, fluid; see Fluid Manifold, page 82

8 24R684 COVER, transformer 1

9+ 261821 CONNECTOR, wire, 6awg 1

10 24U841 COVER, heater 1

11 16W765 COVER, motor 1

12 16W764 COVER, heater, rear 1

24U837 TUBE, b-side, inlet 13

24U839 TUBE, b-side, outlet 14

17 15K742 TRANSFORMER, 4090va, 230/90 1

18 15B456 GASKET, manifold 1

19 125643 FITTING, elbow, 3/8 npt x #8 jic

20 119865 SCREW, mch, hex serrated; 3/8 in. x 1/4–20

Parts

Page 74 of the Graco 333024F user manual — Parts
Page 74 · click to enlarge
Page 74

Quantity Ref Part Description

272010 272011 272012 272110 272111 272112

21 118444 SCREW, mch, slot hex wash hd; 1/2 in. x #10–24

12

22 117683 SCREW, mch, phil pan hd; 1.5 in. x #6–32

8

23 113796 SCREW, flanged, hex hd; 3/4 in. x 1/4–20 11 13 13 11 13 13

24 112731 NUT, hex, flanged 6

25 111800 SCREW, cap, hex hd; 7/32 in. x 5/16–18 4

26 111218 CAP, tube, square 2

27 110996 NUT, hex, flange head 8

28 104859 SCREW, tapping pnhd; 5/16 in. x #10–16 2

29 103181 WASHER, lock ext 4

30 100020 WASHER, lock 2

31 115836 GUARD, finger 1

32 24U847 FAN, cooling, 120mm, 24vdc 2

33 24R685 ENCLOSURE, lower, dinrail; includes 33a-33d

1

33a 24U849 KIT, module, din rail, heater; see Heater and Transformer Terminal Block Module, page 87

1

33b 16W667 INSULATOR, FOAM 1

33c - - - COVER, bottom, dinrail 1

33d 113505 NUT, keps, hex hd 1

34 151395 WASHER, flat 4

35 120685 GROMMET 2

36 114269 GROMMET, rubber 1

37 125625 TIE, cable, fir tree 5 6 6 5 6 6

38 127277 BOLT, carriage, 1/2-13 x 3.5 l 4

39 127278 NUT, keps, hex 4

40 127282 GROMMET, rubber 4

41 16X095 CONNECTOR, power, male, 4 pin

1

42★ 125871 TIE, cable, 7.5 in. 25

43★ 24K207 KIT, fts, rtd, single hose 1

Parts

Page 75 of the Graco 333024F user manual — Parts
Page 75 · click to enlarge
Page 75
Graco 333024F — Parts diagram (page 75)
Fig. 56 · Parts

45★ 106569 TAPE, electrical 1

47 104765 PLUG, pipe headless 2 1

48 16V268 COVER, top, dinrail 1

49 15Y118 LABEL, made in the USA 1

24V150 PROPORTIONER, module, E-30; see Proportioner Module, page 78

24V151 PROPORTIONER, module, E-XP2; see Proportioner Module, page 78

24U321 KIT, asm, pair, elite, reactor; see Fluid Inlet Kits, page 89

24U320 KIT, assembly, pair, std, reactor; see Fluid Inlet Kits, page 89

53 24T050 CABLE, m8 4p f to m12 8p m 1.5m 1 1 1

54 16W130 CABLE, m12 5p, fem - male, 2.0m

55 24U845 TUBE, pressure relief 2

56 191892 FITTING, elbow, street, 90 deg; 1/8 npt 2

57 116746 FITTING, barbed, plated; 1/8–27 npt x 1/4 in. hose I.D.

Parts

Page 76 of the Graco 333024F user manual — Parts
Page 76 · click to enlarge
Page 76
Graco 333024F — Parts diagram (page 76)
Fig. 57 · Parts

60 15G349 COVER, drive, plastic 2

61 16W766 COVER, control, box 1

62 16W596 LATCH, door 2

64★ 206995 FLUID, tsl, 1 qt. 1

65★ 206994 FLUID, tsl 8 oz bottle 1

67★ 114225 TRIM, edge protection; 1.6 ft (0.48 m) 1

68 16X250 LABEL, identification 1

70 127296 SCREW, mchn, pnh, w/ext tooth wash; M4 x 0.7

71 16X129 SCREW, mach, phillips, tooth wash; 5/16 x 8–32

79+★ 261843 FLUID, oxide inhibitor 1

81 16V806 BRACKET, wall, mount 2

83★ 24K409 BAR, 55 gal chem. measure; A side

84★ 24K411 BAR, 55 gal chem. measure. B side

85 127276 BOLT, carriage, 1/2-13 x 2.5 l 2

88 24U854 MODULE, ADM 1

Parts

Page 77 of the Graco 333024F user manual — Parts
Page 77 · click to enlarge
Page 77
Graco 333024F — Parts diagram (page 77)
Fig. 58 · Parts

90 16W213 LABEL, branding, reactor 2

91 115942 NUT, hex, flange head 4

94 127377 TIE, cable, 6 in. 1 1 1

99* 17C258 ENCLOSURE, cover 1

100*▲ 189930 LABEL, caution 1

101*▲ 172953 LABEL, ground 1

102* 17D955 BRACKET, mounting 1

103* 113161 SCREW, flange, hex hd 2

▲Replacement Warning labels, signs, tags, and

See Electrical Schematics, page 91. + Part applies to Series A only.

cards are available at no cost.

★Not shown.

* Part applies to Series B only.

Parts included in Graco Insite Kit 24T280.

Parts

Page 78 of the Graco 333024F user manual — Proportioner Module 24V150, Module for E-30 24V151, Module for E-XP2
Page 78 · click to enlarge
Page 78

Proportioner Module 24V150, Module for E-30 24V151, Module for E-XP2

Graco 333024F — Proportioner Module 24V150, Module for E-30 24V151, Module for E-XP2 diagram (page 78)
Fig. 59 · Proportioner Module 24V150, Module for E-30 24V151,…

2 Lubricate threads with ISO oil or grease. Assemble pump cylinders flush to one full thread under-flush of housing surface.

3 Apply grease to all gear teeth proportionally, motor pinion and drive housing.

5 Crankshaft must be in line with crankshaft at other end of motor.

Parts

Page 79 of the Graco 333024F user manual — Proportioner Module
Page 79 · click to enlarge
Page 79
Graco 333024F — Proportioner Module diagram (page 79)
Fig. 60 · Proportioner Module

101 24U050 MOTOR, brushless, double ended, 2 HP 1 1

102. - - HOUSING, drive, Mark VII 2 2

112 15C753 SCREW, machine, hex wash hd; 1.25 in. x 5/16–18 10 10

113 114666 SCREW, cap, socket head; 2.25 x 3/8–16 8 8

122 127301 SCREW, hexhead, thread cut, 4-40 x 0.375 2 2

▲Replacement Warning labels, signs, tags, and

Gear Repair Kit includes washers (107) and (108).

cards are available at no cost.

★See pump repair manual 309577 for repair kits.

Drive Housing Repair Kit includes housing (1), screws (5), and washer (1) to replace one end.

Spring (110) included in Connecting Rod Kit 241279.

Parts

Page 80 of the Graco 333024F user manual — Fluid Heater
Page 80 · click to enlarge
Page 80

Fluid Heater

24U843 — 10kW, 2–zone 24U842 — 7.5 kW, 1–zone

Graco 333024F — Fluid Heater diagram (page 80)
Fig. 61 · Fluid Heater

5 Apply pipe sealant and PTFE tape to all non-swiveling threads and threads without o-rings.

6 Apply lithium grease lubricant to o-rings before assembling in block (1).

7 Remove tape from probe tip and Orientate sensor as shown. Insert probe until it bottoms on heating element. Tighten ferrule on sensor probe one turn past finger tight or 16 ft-lbs (21.6 N•m).

Parts

Page 81 of the Graco 333024F user manual — 212* - - - SENSOR, RTD 2 1
Page 81 · click to enlarge
Page 81

Ref Part Description 24U843 24U842 15J090 HEATER, machined, 1 zone 1 201

15K825 HEATER, machined, dual zone 1

202 124132 O-RING 4 3

203 15H305 FITTING, plug, hollow, hex, 1-3/16 sae 4 5

204 121309 FITTING, adapter, sae-orb x jic 4 2

205 15H304 FITTING, plug 9/16 sae 2 3

206 15H306 ADAPTER, 9/16 x 1/8 2 1

207 120336 O-RING, packing 2 1

208 16A110 HEATER, immersion, 2550W, 230V 4 3

209 15B137 SWITCH, over temperature 1 1

210 15B135 MIXER, immersion heater 4 3

211* - - - FITTING, compression 2 1

212* - - - SENSOR, RTD 2 1

213 124131 SCREW, machine, pnhd; 5/16 in. x #6–32 2 2

214 15M178 HOUSING, rupture disc 2 1

* Included in 24L973 Heater RTD Repair Kit.

Parts

Page 82 of the Graco 333024F user manual — Fluid Manifold
Page 82 · click to enlarge
Page 82

Fluid Manifold

24U844

Graco 333024F — Fluid Manifold diagram (page 82)
Fig. 62 · Fluid Manifold

4 Apply PTFE tape and thread sealant to gauge threads.

1 Torque to 355–395 in.-lbs (40–44.6 N●m)

2 Apply sealant (113500) to threads.

5 Apply grease on valve.

3 Valve must be closed with handle position as shown on drawing.

** Apply PTFE tape or thread sealant to tapered threads.

Parts

Page 83 of the Graco 333024F user manual — 404 162453 FITTING, 1/4 NPSM X 1/4 NPT
Page 83 · click to enlarge
Page 83

24U844, Fluid Manifold

Ref Part Description Qty

Ref Part Description Qty

401 255228 MANIFOLD, fluid 1

413 100840 FITTING, elbow, street 2

402★ 247824 KIT, valve, cartridge, drain 2

414 111457 O-RING, PTFE 2

402a★158674 O-RING, BUNA-N 1

415▲ 189285 LABEL, caution 1

402b★247779 SEAL, seat, valve 1

416 150829 SPRING, compression 2

403 102814 GAUGE, press, fluid 2

419 117557 NIPPLE, #10 JIC x 1/2 NPT

404 162453 FITTING, 1/4 NPSM X 1/4 NPT

▲ Replacement Warning labels, signs, tags, and cards are available at no cost.

405 15M669 SENSOR, pressure, fluid outlet

★ Included in the following complete valve kits: ISO Valve Kit (left/red) handle 255149. Resin Valve Kit (right/blue handle) 255150. Valve Set Kit (both handles and grease gun) 255148.

406 247788 HANDLE, red 1

407 247789 HANDLE, blue 1

408 112309 NUT, hex, jam 2

411 117556 NIPPLE, #8 JIC x 1/2 NPT 1

412 121312 FITTING, elbow, 3/4 SAE x 1/2 JIC

Parts

Page 84 of the Graco 333024F user manual — Electrical Enclosure
Page 84 · click to enlarge
Page 84

Electrical Enclosure

Graco 333024F — Electrical Enclosure diagram (page 84)
Fig. 63 · Electrical Enclosure

Parts

Page 85 of the Graco 333024F user manual — Electrical Enclosure
Page 85 · click to enlarge
Page 85

Electrical Enclosure

Ref Part Description Qty 451 24U087 ENCLOSURE 1 453 24U855 MODULE, TCM 1 454 24U848 FAN, cooling, 80 mm, 24VDC 1 455 24R736 SWITCH, disconnect, door mounted 1 457 117666 TERMINAL, ground 1 458 120859 NUT, strain relief, M40 thread 1 459 120858 BUSHING, strain relief, M40 thread 1 460 123967 KNOB, operator disconnect 1 461 115942 NUT, hex, flange head 5 462 103181 WASHER, lock external 2 463 124131 SCREW, machine, pan head; 5/16 in. x #6–32 2 464 194337 WIRE, grounding, door 1 466 113505 NUT, keps, hex head 6

Ref Part Description Qty 468 111218 CAP, tube, square 2 469 114269 GROMMET, rubber 1 470 127282 GROMMET, rubber 2 471 127278 NUT, keps, hex 4 472 16W925 GASKET, enclosure, foam 2 473 16W926 GASKET, enclosure, foam 2 474 24R735 CABLE, CAN power, M12 female, pigtail 1 475 127068 CABLE, CAN, female/female 1.0 meter 2 476 24U850 MODULE, breaker 1 477 127290 CABLE, 4-pin, male/female, 1.3 meter, molded (hose RTD) 1 478▲ 16X050 LABEL, safety; enclosure 1 479▲ 16X049 LABEL, safety; multi 1

▲Replacement Warning labels, signs, tags, and

cards are available at no cost.

See Electrical Schematics, page 91.

Parts

Page 86 of the Graco 333024F user manual — System DIN Rail and Harness Module Kit
Page 86 · click to enlarge
Page 86

System DIN Rail and Harness Module Kit

24U850, System DIN Rail and Harness Module Kit

See Electrical Schematics, page 91.

Graco 333024F — System DIN Rail and Harness Module Kit diagram (page 86)
Fig. 64 · System DIN Rail and Harness Module Kit

1 Torque to 6–8 in.-lbs (0.7–1 N●m)

2 Torque to 28–33 in.-lbs (3–3.8 N●m)

3 Torque to 23–26 in.-lbs (2.6–3 N●m)

Parts

Page 87 of the Graco 333024F user manual — Heater and Transformer Terminal Block Module
Page 87 · click to enlarge
Page 87

Ref Part Description Qty 501 16U529 HARNESS, breaker module 1 502 16V515 HARNESS, hose out 1 503 16U522 MODULE, din rail, term blk, power sup; see System Circuit Breaker Module, page 88 1

Ref Part Description Qty 504 16U526 MODULE, din rail, circuit breakers; see Power Supply and Terminal Block Module, page 88 1 505 16U530 MODULE, sys surge protector 1

Heater and Transformer Terminal Block Module

24U849

Graco 333024F — Heater and Transformer Terminal Block Module diagram (page 87)
Fig. 65 · Heater and Transformer Terminal Block Module

Ref Part Description Qty 511 24T315 RAIL, DIN; 35 mm x 7.5 mm x 7 in.

Ref Part Description Qty 515 120570 BLOCK, terminal 6

516 24R758 BLOCK, terminal, UT-2.5, red

512 126811 BLOCK, clamp, end 2

513 126383 COVER, end 1

517 24R759 BLOCK, terminal, UT-2.5, black

514 126382 BLOCK, terminal 2

Parts

Page 88 of the Graco 333024F user manual — 535 126453 POWER SUPPLY, 24V 1
Page 88 · click to enlarge
Page 88

System Circuit Breaker Module 16U526

Graco 333024F — System Circuit Breaker Module 16U526 diagram (page 88)
Fig. 66 · System Circuit Breaker Module 16U526

Ref Part Description Qty 521 514014 RAIL, DIN; 35 mm x 7.5 mm x 8.625 in. 1

Ref Part Description Qty 524 17A314 CIRCUIT, breaker, 2P, 20A, UL489 1

522 120838 TERMINAL, end stop 2

525 17A317 CIRCUIT, breaker, 2P, 40A, UL489 3

523 17A319 CIRCUIT, breaker, 1 pole, 50A, C Curve

Power Supply and Terminal Block Module 16U522

Graco 333024F — Power Supply and Terminal Block Module 16U522 diagram (page 88)
Fig. 67 · Power Supply and Terminal Block Module 16U522

Ref Part Description Qty 531 514014 RAIL, DIN; 35 mm x 7.5 mm x 8.625 in.

Ref Part Description Qty 534 24R723 BLOCK, terminal, quad M4, ABB

532 120838 TERMINAL, end stop 3

535 126453 POWER SUPPLY, 24V 1

533 24R722 BLOCK, terminal PE, quad, ABB

536 24R724 BLOCK, terminal, UT35 6

Parts

Page 89 of the Graco 333024F user manual — Fluid Inlet Kits
Page 89 · click to enlarge
Page 89

Fluid Inlet Kits

24U320, Standard 24U321, Elite

Graco 333024F — Fluid Inlet Kits diagram (page 89)
Fig. 68 · Fluid Inlet Kits

1 Apply sealant to all tapered pipe threads. Apply sealant to female threads. Apply to at least the first four threads and approximately 1/4 turn wide.

2 Apply thermal paste to the stem of dial before assembling into housing.

Parts

Page 90 of the Graco 333024F user manual — 24U320 24U321
Page 90 · click to enlarge
Page 90

Quantity Ref Part Description

24U320 24U321

601 160327 FITTING, union adapter, 90° 2 2

602 118459 FITTING, union, swivel, 3/4 in. 2 2

603 247503 MANIFOLD, strainer, inlet 2 2

604 24U852 THERMOMETER, dial 2 2

605 24U853 GAUGE, press, fluid 2 2

606★ - - - FILTER, replacement 2 2

607★ C20203 PACKING, o-ring, 1.17, fluoroelastomer 2 2

608 16V879 CAP, filter 2 2

609 555808 PLUG, 1/4mp w/ hex hd 2 2

610 15D757 HOUSING, thermometer, viscon hp 2 2

613 109077 VALVE, ball 3/4 npt 1 2

614 C20487 FITTING, nipple, hex 2

614 624545 FITTING, tee 3/4m run x 1/4f branc 2

615 24U851 TRANSDUCER, pressure, temperature (includes foam) 2

* Optional 80 mesh filter 255082 (2 pack)

★Included in 24V020 Inlet Filter and Seal Kit, 20

mesh (2 pack).

Included in 247503 Manifold Repair Kit.

Parts

Page 91 of the Graco 333024F user manual — Electrical Schematics
Page 91 · click to enlarge
Page 91

Electrical Schematics

Graco 333024F — Electrical Schematics diagram (page 91)
Fig. 69 · Electrical Schematics

Electrical Schematics

Page 92 of the Graco 333024F user manual — Electrical Schematics
Page 92 · click to enlarge
Page 92
Graco 333024F — Electrical Schematics diagram (page 92)
Fig. 70 · Electrical Schematics
Graco 333024F — Electrical Schematics diagram (page 92)
Fig. 71 · Electrical Schematics

Electrical Schematics

Page 93 of the Graco 333024F user manual — Electrical Schematics
Page 93 · click to enlarge
Page 93
Graco 333024F — Electrical Schematics diagram (page 93)
Fig. 72 · Electrical Schematics

2 Heated hose wire termination enclosure (series B only).

Electrical Schematics

Page 94 of the Graco 333024F user manual — Recommended Common Spare Parts
Page 94 · click to enlarge
Page 94

Reactor 2 Repair Spare Parts Reference

Reactor 2 Repair Spare Parts Reference

Recommended Common Spare Parts

Ref Part Description Part of Assembly

106, 115 15C852 E-30 Pump Repair Kit Pump

106, 115 15C851 E-XP2 Pump Repair Kit Pump

106, 115 246963 E-XP2 Wet Cup Repair Kit Pump

106, 115 246964 E-30 Wet Cup Repair Kit Pump

606, 607 24V020 Y-Strainer Filter and Gasket Kit (pack of two each)

402 247824 Drain Valve Cartridge Fluid Manifold

403 102814 Fluid Pressure Gauge Fluid Manifold

405 15M669 Pressure Sensor Fluid Manifold

211, 212 24L973 RTD Repair Kit Heater

-- 24K207 Hose FTS Hose

-- 24N450 RTD Cable (50 ft. replacement) Hose

-- 24N365 RTD Cable Test Kit (To assist measureing RTDs and RTD cable resistances)

Y-Strainer · Hose

Page 95 of the Graco 333024F user manual — AR4242
Page 95 · click to enlarge
Page 95

Performance Charts

Use these charts to help identify the proportioner that will work most efficiently with each mix chamber. Flow rates are based on a material viscosity of 60 cps.

Proportioners For Foam

AR4242

AR5252

AR6060

PRESSURE

AR7070

E-30

500 (34) 0 5 (2.3)

40 (18.1) 10 (4.5)

15 (6.8)

20 (9.1)

25 (11.3)

30 (13.6)

35 (15.9)

Show 10 more labels / short text on this page
Performance Charts · 2000 (138) · (01) · 1500 (103) · (02) · (03) · psi (bar) · 1000 (69) · (04) · FLOW lbs/min (kg/min)
Page 96 of the Graco 333024F user manual — AF5252 (FTXX48 TIP)
Page 96 · click to enlarge
Page 96

Proportioners For Coatings

Table 1 Fusion Air Purge, Round Pattern

AR2020

E-XP2

PRESSURE

AR2929

AR4242

0 0.5 (1.9)

1.5 (5.7) 1.0 (3.8)

2.0 (7.6)

FLOW gal./min (l/min)

Table 2 Fusion Air Purge, Flat Pattern

3500 (241, 24.1)

3000 (207, 20.7)

2500 (174, 17.4)

AF2929 (FTXX38 TIP)

AF2020 (FTXX24 TIP)

PRESSURE

2000 (138, 13.8)

AF4242 (FTXX38 TIP)

E-XP2

1500 (103, 10.3)

AF5252 (FTXX48 TIP)

1000 (69, 6.9)

500 (35, 3.5)

0 0.5 (1.9)

1.5 (5.7) 1.0 (3.8)

2.0 (7.6)

FLOW gal./min (l/min)

Show 13 more labels / short text on this page
Performance Charts · 3500 (241) · 3000 (207) · 2500 (172) · (000) · 2000 (138) · psi (bar) · (00) · 1500 (103) · (01) · 1000 (69) · 500 (34) · psi (bar)
Page 97 of the Graco 333024F user manual — XF5757 (FTM638)
Page 97 · click to enlarge
Page 97

Table 3 Fusion Mechanical Purge, Round Pattern

3500 (241, 24.1)

3000 (207, 20.7)

E-XP2

XR2323 (RTM040)

2500 (174, 17.4)

XR2929 (RTM040)

PRESSURE

2000 (138, 13.8)

MR3535 (RTM040)

1500 (103, 10.3)

MR4747 (RTM055) XR3535 (RTM055) XR4747 (RTM055)

1000 (69, 6.9)

500 (35, 3.5)

0 0.5 (1.9)

1.5 (5.7) 1 (3.8)

2.0 (7.6)

FLOW gal./min (l/min)

Table 4 Fusion Mechanical Purge, Flat Pattern

3500 (241, 24.1)

XF1313 (FTM424)

XF2323 (FTM424)

3000 (207, 20.7)

MF2929 (FTM424)

2500 (174, 17.4)

MF4747 (FTM638)

XF2929 (FTM424)

MF1818 (FTM424)

2000 (138, 13.8)

PRESSURE

E-XP2

XF1818 (FTM424)

MF5757 (FTM638)

MF3535 (FTM638)

1500 (103, 10.3)

XF5757 (FTM638)

XF3535 (FTM638)

1000 (69, 6.9)

500 (35, 3.5)

0 0.4 (1.5)

0.8 (3.0) 0.2 (0.7)

0.6 (2.3)

1.8 (6.8) 1 (3.8)

1.4 (5.3) 1.2 (4.5)

1.6 (6.0)

2.0 (7.6)

FLOW gal./min (l/min)

Performance Charts · psi (bar) · psi (bar)

Page 98 of the Graco 333024F user manual — Technical Specifications
Page 98 · click to enlarge
Page 98

Technical Specifications

Graco 333024F — Technical Specifications diagram (page 98)
Fig. 73 · Technical Specifications

E-30 190°F 88°C E-XP2 190°F 88°C Maximum Flow Rate

E-30 150°F 66°C E-XP2 150°F 66°C Maximum Inlet Fluid Pressure

Output per Cycle ISO and RES E-30 0.0272 gal. 0.1034 liter

Operating Ambient Temperature Range Temperature 20° to 120°F -7° to 49°C Line Voltage Requirement

Nominal 200–240 VAC, 1 Phase, 50/60 Hz 195–265 VAC

Nominal 200–240 VAC, 3 phase, DELTA, 50/60 Hz 195–265 VAC

Nominal 350–415 VAC, 3 phase, WYE, 50/60 Hz 340–455 VAC

Heater Power (at 230 VAC rated voltage) E-30 10 kW 10,200 Watts

Technical Specifications

Page 99 of the Graco 333024F user manual — Technical Specifications
Page 99 · click to enlarge
Page 99

Sound Pressure Sound Pressure measured per ISO-9614–2. E-30 Measured from 3.1 ft (1 m), at 1000 psi (7 MPa, 70 bar), 3 gpm (11.4 lpm)

87.3 dBA

E-XP2 Measured from 3.1 ft (1 m), at 3000 psi (21 MPa, 207 bar), 1 gpm (3.8 lpm)

79.6 dBA

Sound Power E-30 Measured from 3.1 ft (1 m), at 1000 psi (7 MPa, 70 bar), 3 gpm (11.4 lpm)

93.7 dBA

E-XP2 Measured from 3.1 ft (1 m), at 3000 psi (21 MPa, 207 bar), 1 gpm (3.8 lpm)

86.6 dBA

Component A ISO) and Component B (RES)

3/4 NPT(f) with 3/4 NPSM(f) union

Component A (ISO) #8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter

Component B (RES) #10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter

Size 1/4 NPSM(m) Maximum Pressure 250 psi 1.75 MPa, 17.5 bar

Width 26.3 in. 668 mm

Height 63 in. 1600 mm

Depth 15 in. 381 mm

E-30, 10 kW 315 lb 143 kg

E-30, 15 kW 350 lb 159 kg

E-30, 10 kW Elite 320 lb 145 kg

E-30, 15 kW Elite 355 lb 161 kg

E-XP2 345 lb 156 kg

E-XP Elite 350 lb 159 kg

Material Aluminum, stainless steel, zinc plated carbon steel, brass, carbide, chrome, chemically resistant o-rings, PTFE, ultra-high

Show 8 more labels / short text on this page
Technical Specifications · Fluid Inlets · Fluid Outlets · Fluid Circulation Ports · Dimensions · Weight · Wetted Parts · molecular weight polyethylene
Page 100 of the Graco 333024F user manual — Notes
Page 100 · click to enlarge
Page 100

Notes

Page 101 of the Graco 333024F user manual — FOR GRACO CANADA CUSTOMERS
Page 101 · click to enlarge
Page 101

Graco Extended Warranty for Reactor ® 2 Components

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

Graco Part Number Description Warranty Period

24U050 24U051 Electric Motor 36 Months or 3 Million Cycles

24U831 Motor Control Module 36 Months or 3 Million Cycles

24U832 Motor Control Module 36 Months or 3 Million Cycles

24U855 Heater Control Module 36 Months or 3 Million Cycles

24U854 Advanced Display Module 36 Months or 3 Million Cycles

All other Reactor 2 parts 12 Months

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty hereunder must be brought within the latter of two (2) years of the date of sale, or one (1) year the warranty period expires.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Page 102 of the Graco 333024F user manual — Graco Information
Page 102 · click to enlarge
Page 102

Graco Information

For the latest information about Graco products, visit www.graco.com

To place an order, contact your Graco Distributor or call to identify the nearest distributor.

Phone612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents

Original Instructions. This manual contains English. MM 333024

Graco HeadquartersMinneapolis
International OfficesBelgium, China, Japan, Korea
  • GRACO INC. AND SUBSIDIARIES
  • P.O. BOX 1441
  • MINNEAPOLIS MN 55440-1441
  • USA

Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Revision F, July 2015

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
DE0XCycle Switch ErrorCheck wiring between cycle switch and MCM. p.17
F9DXHigh Pressure/Flow CutbackReference the pressure flow curves and select a tip size that is the correct size for the set pressure. p.18
H2MALow Frequency AEnsure line frequency of incoming power is between 45 and 65 Hz. p.18
H2MBLow Frequency BEnsure line frequency of incoming power is between 45 and 65 Hz. p.18
H2MHLow Frequency HoseEnsure line frequency of incoming power is between 45 and 65 Hz. p.18
H3MAHigh Frequency AEnsure line frequency of incoming power is between 45 and 65 Hz. p.18
H3MBHigh Frequency BEnsure line frequency of incoming power is between 45 and 65 Hz. p.18
H3MHHigh Frequency HoseEnsure line frequency of incoming power is between 45 and 65 Hz. p.18
K8NMLocked Rotor MotorRemove pump gear housings from motor and check that motor shaft rotates freely in direction indicated on motor housing. p.18
L1AXLow Chemical Level ARefill material and update drum level on ADM Maintenance screen. Alarm can be disabled on the System Setup screen. p.19
L1BXLow Chemical Level BRefill material and update drum level on ADM Maintenance screen. Alarm can be disabled on the System Setup screen. p.19
P0AXPressure Imbalance A HighEnsure material flow is equally restricted on both material lines. p.19
P0BXPressure Imbalance B HighEnsure material flow is equally restricted on both material lines. p.20
P1FALow Inlet Pressure AEnsure that inlet pressure to the pump is sufficient. p.20
P1FBLow Inlet Pressure BEnsure that inlet pressure to the pump is sufficient. p.20
P2FALow Inlet Pressure AEnsure that inlet pressure to the pump is sufficient. p.20
P2FBLow Inlet Pressure BEnsure that inlet pressure to the pump is sufficient. p.21
P4AXHigh Pressure APressure in the hose and pumps will increase as the system heats up. Turn on heat and allow all zones to reach the temperature setpoint before turning on the pumps. p.21
P4BXHigh Pressure BPressure in the hose and pumps will increase as the system heats up. Turn on heat and allow all zones to reach the temperature setpoint before turning on the pumps. p.21
P6AXPressure Sensor Error ACheck to ensure the pressure transducer is properly installed and all wires are properly connected. p.22
P6BXPressure Sensor Error BCheck to ensure the pressure transducer is properly installed and all wires are properly connected. p.22
P6FAPressure Sensor Error Inlet AIf inlet sensors are not installed, inlet sensors should be disabled on the System Setup screen. p.22
P6FBPressure Sensor Error Inlet BIf inlet sensors are not installed, inlet sensors should be disabled on the System Setup screen. p.23
P7AXPressure Imbalance A HighEnsure material flow is equally restricted on both material lines. p.23
P7BXPressure Imbalance B HighEnsure material flow is equally restricted on both material lines. p.24
T2DALow Temperature AUse a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint. p.24
T2DBLow Temperature BUse a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint. p.25
T2DHLow Temperature HoseUse a smaller mix chamber that is rated for the unit in use. If recirculating, decrease flow or decrease temperature setpoint. p.25
T2FALow Temperature Inlet ARecirculate fluid through heaters until inlet fluid temperature is above defined error level. p.25
T2FBLow Temperature Inlet BRecirculate fluid through heaters until inlet fluid temperature is above defined error level. p.25
T3CHHose CutbackHose setpoint higher than A and B setpoints. Decrease hose setpoint. p.26
T3CTTCM CutbackEnsure ambient temperature is below 120°F(48°C) before using the system. p.26
T3NMMotor Temperature CutbackThe system is running at a lower setpoint to preserve motor life. Run the system at a lower duty cycle or with a smaller mix chamber. p.26
T3CMMCM Temperature CutbackEnsure ambient temperature is below 120°F(48°C). Verify that all fans are working. p.26
T4CMHigh Temperature MCMEnsure ambient temperature is below 120°F(48°C) before using the system. p.26
T4CTHigh Temperature TCMEnsure ambient temperature is below 120°F(48°C) before using the system. p.27
T4DAHigh Temperature ASwap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD. p.27
T4DBHigh Temperature BSwap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD. p.27
T4DHHigh Temperature HoseShade exposed hose from hot sun or expose FTS to same environment when at rest. Uncoil entire hose before heating to avoid self-heating. p.28
T4EAHigh Temperature Switch AHeater was delivered too much power, causing the overtemperature switch to open. RTD is not reading properly. After the heater cools down, replace RTD. Switch closes and the error can be cleared when the heater temperature falls below 190°F (87°C). p.28
T4EBHigh Temperature Switch BHeater was delivered too much power, causing the overtemperature switch to open. RTD is not reading properly. After the heater cools down, replace RTD. Switch closes and the error can be cleared when the heater temperature falls below 190°F (87°C). p.29
T4NMHigh Temperature MotorCheck to see that the motor fan is moving. Measure voltage to fan. There should be 24 VDC. If no voltage is measured, check fan wiring. If the fan has voltage but is not moving, replace fan. If necessary use an air hose to blow out around the fan housings and remove any built-up debris. p.29
T6DASensor Error ACheck all wiring and connection to RTD. p.29
T6DBSensor Error BCheck all wiring and connection to RTD. p.30
T6DHSensor Error HoseExpose each hose RTD connection to check and retighten any loose con- nector. Measure hose RTD cable and FTS continuity. See Repair Heated Hose, page 64. Order RTD Test kit 24N365 for measure- ment. Disconnect hose RTD and use manual hose mode to finish job until repair can be completed. p.30
T6DTSensor Error TCMExpose each hose RTD connection to check for exposed and shorted RTD wires. Measure hose RTD cable and FTS continuity. See Repair Heated Hose, page 64. Order RTD Test kit 24N365 for measure- ment. Disconnect hose RTD and use manual hose mode to finish job until repair can be completed. p.30
T8DANo Temperature Rise ASwap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD. p.31
T8DBNo Temperature Rise BSwap A and B heater output cables and RTD cables and see if issue follows. If so, replace RTD. p.31
T8DHNo Temperature Rise HoseWait until operating temperature has been reached before spraying or recirculating. p.31
V1CMLow Voltage MCMCheck wiring for loose connection or tripped circuit breaker. p.31
V1ITLow Voltage CANCheck voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply. p.32
V2ITLow Voltage CANCheck voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply. p.32
V2MALow Voltage ACheck wiring for loose connection or tripped circuit breaker. p.32
V2MBLow Voltage BCheck wiring for loose connection or tripped circuit breaker. p.32
V2MHLow Voltage HoseCheck wiring for loose connection or tripped circuit breaker. p.32
V3ITHigh Voltage CANCheck voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply. p.32
V3MAHigh Voltage AEnsure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. p.32
V3MBHigh Voltage BEnsure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. p.33
V3MHHigh Voltage HoseEnsure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. p.33
V4CMHigh Voltage MCMEnsure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. p.33
V4ITHigh Voltage CANCheck voltage of power supply. Voltage should be 23-25 VDC. If out of tolerance, replace power supply. p.33
V4MAHigh Voltage AEnsure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. p.33
V4MBHigh Voltage BEnsure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. p.33
V4MHHigh Voltage HoseEnsure incoming system power is wired properly. Verify voltage at each circuit breaker is between 195 and 264 VAC. p.33
WBC0Software Version ErrorInsert a system token into the ADM module and cycle the power. Wait until the upload is complete before removing the token. p.34
WMI0TCM Fan ErrorCheck for debris in the TCM fan and clear with forced air if necessary. p.34
TB18Verify voltage is approximately 90 p.67
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Reactor ADM does not turn on.No power.Turn main power switch ON. p.35
Reactor ADM does not turn on.Failed 24 V power supply.Replace power supply. p.35
Reactor ADM does not turn on.Failed surge protector.Replace surge protector. p.35
Electric motor does not operate.Loose connections.Check MCM connection 13. p.35
Electric motor does not operate.Tripped circuit breaker (CB02).Reset breaker, see Repair Circuit Breaker Module, page 55. Check 240VAC at output of breaker. p.35
Electric motor does not operate.Shorted windings.Replace motor, see Repair Electric Motor, page 54. p.35
Electric motor runs erratically.Failed motor bearing.Replace motor, see Repair Electric Motor, page 54. p.35
Cooling fans not working.Loose wire.Check. See Electrical Schematics, page 91. p.36
Cooling fans not working.Fan blade obstructed.Remove obstruction. p.36
Cooling fans not working.Defective fan.Replace. See Replace Motor Fan, page 57. p.36
Pump output low.Obstructed fluid hose or gun; fluid hose ID too small.Open, clear; use hose with larger ID. p.36
Pump output low.Worn piston valve or intake valve in displacement pump.See pump manual. p.36
Pump output low.Pressure setpoint too high.Reduce setpoint and output will increase. p.36
Fluid leak in pump packing nut area.Worn throat seals.Replace. See pump manual. p.36
No pressure on one side.Fluid leaking from heater inlet rupture disk (372).Check if heater and PRESSURE RELIEF/SPRAY valve (SA or SB) are plugged. Clear. Replace rupture disk (372) with a new one; do not replace with a pipe plug. p.36
Hose heats but heats slower than usual or it does not reach temperature.Ambient temperature is too cold.Relocate hoses to a warmer area or recirculate heated fluid through the hose. p.37
Hose heats but heats slower than usual or it does not reach temperature.FTS failed or not installed correctly.Check FTS, see Check RTD Cables and FTS, page 65. p.37
Hose heats but heats slower than usual or it does not reach temperature.Low supply voltage.Verify line voltage. Low line voltage significantly reduces power available to the hose heat system, affecting longer hose lengths. p.37
Hose does not maintain temperature while spraying.A and B setpoints too low.Increase A and B setpoints. Hose is designed to maintain temperature, not to increase it. p.37
Hose does not maintain temperature while spraying.Ambient temperature is too cold.Increase A and B setpoints to increase fluid temperature and keep it steady. p.37
Hose does not maintain temperature while spraying.Flow too high.Use smaller mix chamber. Decrease pressure. p.37
Hose does not maintain temperature while spraying.Hose was not fully preheated.Wait for hose to heat to correct temperature before spraying. p.37
Hose does not maintain temperature while spraying.Low supply voltage.Verify line voltage. Low line voltage significantly reduces power available to the hose heat system, affecting longer hose lengths. p.37
Hose temperature exceeds setpoint.A and/or B heaters are overheating material.Check primary heaters for either a RTD problem or a failed element attached to RTD, see Electrical Schematics, page 91. p.38
Hose temperature exceeds setpoint.Faulty FTS connections.Verify that all FTS connections are snug and that pins of connectors are clean. Unplug and re-plug RTD wires, cleaning off any debris. p.38
Hose temperature exceeds setpoint.Ambient temperature is too high.Cover hoses or move to a location with a lower ambient temperature. p.38
Hose temperature exceeds setpoint.Missing or damaged insulation around FTS, causing the hose heat to be ON constantly.Make sure the hose bundle has adequate insulation evenly covering the entire length and connection joints. p.38
Erratic hose temperature.Faulty FTS connections.Verify that all FTS connections are snug and that pins of connectors are clean. Unplug and re-plug FTS wires along length of hose, cleaning off any debris. p.39
Erratic hose temperature.FTS not installed correctly.FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, see Repair Fluid Temperature Sensor (FTS), page 66. p.39
Erratic hose temperature.Missing or damaged insulation around FTS, causing the hose heat to be ON constantly.Make sure the hose bundle has adequate insulation evenly covering the entire length and connection joints. p.39
Hose does not heat.FTS failed.Check FTS, see Repair Fluid Temperature Sensor (FTS), page 66. p.39
Hose does not heat.FTS not installed correctly.FTS should be installed close to end of hose in same environment as gun. Verify FTS installation, see Repair Fluid Temperature Sensor (FTS), page 66. p.39
Hose does not heat.Loose hose electrical connections.Check connections. Repair as necessary. p.39
Hose does not heat.Circuit breakers tripped.Reset breakers (CB01 ), see Repair Circuit Breaker Module, page 55. p.39
Hose does not heat.Hose zone not turned on.Turn on hose heat zone. p.39
Hose does not heat.A and B temperature setpoints too low.Check. Increase if necessary. p.39
Hoses near Reactor are warm, but hoses downstream are cold.Shorted connection or failed hose heating element.With power off, check the hose resistance with and without the whip hose attached. With the whip hose attached, the reading should be less than 3 ohm. With- out the whip hose attached, the reading should be OL (open loop). See Check Hose Heat Power Connectors, page 64. p.40
Low hose heat.A and B temperature setpoints too low.Increase A and B setpoints. Hose designed to maintain temperature, not increase temperature. p.40
Low hose heat.Hose temperature setpoint too low.Check. Increase if necessary to maintain heat. p.40
Low hose heat.Flow too high.Use smaller mix chamber. Decrease pressure. p.40
Low hose heat.Low current; FTS not installed.Install FTS, see operation manual. p.40
Low hose heat.Hose heat zone not turned on long enough to reach setpoint.Allow hose to heat up, or preheat fluid. p.40
Low hose heat.Loose hose electrical connections.Check connections. Repair as necessary. p.40
Low hose heat.Ambient temperature is to lowRelocate hoses to a warmer area or increase A and B setpoints. p.40
Primary Heater(s) does not heat.Heat turned off.Turn on heat zones. p.41
Primary Heater(s) does not heat.Temperature control alarm.Check ADM for error codes. p.41
Primary Heater(s) does not heat.Signal failure from RTD. p.41
Control of primary heat is abnormal; high temperature overshoots (T4DA, T4DB) occurs intermittently.Dirty RTD connections.Examine RTD cables connected to TCMs. Confirm RTDs are not plugged into opposite heat zone. Unplug and re-plug RTD connectors. Unplug and re-plug RTD connectors. Ensure RTD tip contacts the heater element. p.41
Control of primary heat is abnormal; high temperature overshoots (T4DA, T4DB) occurs intermittently.RTD not contacting heater element.Loosen ferrule nut, push in RTD so tip contacts heater element. Holding RTD tip against heater element, tighten ferrule nut 1/4 turn past tight. p.41
Control of primary heat is abnormal; high temperature overshoots (T4DA, T4DB) occurs intermittently.Failed heater element.See Replace Heater Element, page 60. p.41
Control of primary heat is abnormal; high temperature overshoots (T4DA, T4DB) occurs intermittently.Signal failure from RTD.See (T6DA, T6DB), Error Codes. p.41
No module status LEDs are illuminated.No power to cellular module.Turn Reactor ON. p.42
No module status LEDs are illuminated.Ensure unit is properly installed. p.42
No module status LEDs are illuminated.Verify 24V at output of the power supply. p.42
No module status LEDs are illuminated.Make sure the M8, 4–pin to M12, 8–pin cable is installed between cellular module and power supply. p.42
Has not identified GPS location (green module status LED flashing).Still identifying location.Wait a few minutes for the unit to identify the location. p.42
Has not identified GPS location (green module status LED flashing).Unable to identify location. In a location where GPS lock cannot occur. Buildings and warehouses often prevent GPS locks.Move system to a location with a clear view of the sky. p.42
Has not identified GPS location (green module status LED flashing).Use extension cable 16X521 and move cellular module to a location with a clear view of the sky. p.42
Has not established cellular connection (orange module status LED flashing).Still establishing cellular connection.Wait a few minutes for the unit to establish the connection. p.42
Has not established cellular connection (orange module status LED flashing).Unable to establish cellular connection.Move system to a location with cellular service to establish cellular connection. p.42
Has not established cellular connection (orange module status LED flashing).Use extension cable 16X521 and move cellular module to a location with a clear view of the sky. p.42
Cannot view data for my unit(s) on website.Graco InSite unit has not been activated.Activate unit. See Registering and Activating the Graco InSite section. p.42
Temperature data not displayed on website.Reactor temperature measurement is not working.See System troubleshooting section. p.42
Hose zone temperature data not displayed on website.The RTD or thermocouple is not correctly installed on the hose or is broken.See RTD or Thermocouple repair section. p.42
Pressure data not displayed on website.Reactor pressure measurement is not working.See System troubleshooting section. p.42

Ask about the Graco 333024F

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 333024F

Be the first to ask — other owners or our team will answer.

Original document

Graco 333024F manual PDF

102 pages·13.2 MB·DVD Player·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…