Supply Systems
For use with non-heated bulk supply of medium to high viscosity sealants and adhesive materials. For professional use only.
Not for use in European explosive atmosphere locations.
L20c 2 inch single post elevator 20 liter (5 gallon) size 100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure

S20 3 inch single post 20 liter (5 gallon) size 125 psi (0.9 MPa, 9 bar) Maximum Air Inlet Pressure
D60 3 inch dual post 60 liter (16 gallon) size, 30 liter (8 gallon), 20 liter (5 gallon) sizes 150 psi (1.0 MPa, 10bar) Maximum Air Inlet Pressure
D200 3 inch dual post 200 liter (55 gallon), 115 liter (30 gallon), 60 liter (16 gallon) size, 30 liter (8 gallon), 20 liter (5 gallon) sizes 150 psi (1.0 MPa, 10 bar) Maximum Air Inlet Pressure
D200S 6.5 inch dual post 55 gallon (200 liter), 30 gallon (115 liter) sizes 125 psi (0.9 MPa, 9 bar) Maximum Air Inlet Pressure
See page 6 for model information and approvals.
The Graco Control Architecture Electric Components are Listed in Intertek’s Directory of Listed Products.
ti10429a Model CM14BA


The following manuals are available at www.graco.com Component Manuals in English:
Related Manuals

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.


Check the identification plate (ID) for the 6-digit part number of the supply sys- tem. Use the following matrix to define the construction of the supply system, based on the six digits. For example, Part No. CM14BA represents a Check-Mate supply system (CM), a carbon steel Check-Mate 100 MaxLife® displacement pump with an NXT 2200 air motor with remote DataTrak (pump code 14), a 3 in. dual post ram with integrated air controls (B) and a 55-gallon, uncoated platen with a neoprene seal (A).

Systems with the GD as the first and second digits are Dura-Flo supply systems. Some configurations in the following matrix cannot be built. See the Product Selection guide for available systems.
To order replacement parts, see Parts section in manual 313527. The digits in the matrix on the next page do not correspond to the Ref. Nos. in the Parts drawings and lists.
All supply systems with DataTrak and 24 Vdc or 100-240 Vac power supplies are ETL approved.
#ERTIFIEDTO#!.#3!#3! #.O
#ONFORMSTO5,
Models · #-

S = Single post ram i = 2-Button Interlock F = Flat SW = Single wiper c = Cart mounted s = 6.5 inch D = D Style DW = Double wiper D = Dual post ram INT = Integrated air controls DR = Dual o-ring
* Other Available Models: 262868. This model is the same as CM-_ _-3-B models, such as CM-11-3-B, but uses Check-Mate Pump P40DCS (NXT2200/CM 100) instead of the other pumps listed on page 8.
Models





See manual 312376 or the ID plate on the pump to determine pump part number.
Models





NR = Not released
Models

D200 3 in. and D200s 6.5 in. Dual Post

H
Key: A Ram Assembly B Air Motor C Displacement Pump D Platen E Remote DataTrak (single ram systems) or Display Module (tandem systems) G Integrated Air Controls (see FIG. 3) H Air Motor Lift Ring J Platen Bleed Port K Power Supply Box M Blowoff Air Supply Line
N Platen Lift Rod P Pump Bleeder Valve R Enclosed Wet Cup S Fluid Line (not supplied) T Main Air Line (not supplied) U Air Line Drain Valve (not supplied) V Air Filter (not supplied) W Bleed Type Air Shutoff Valve (not supplied) X Air Motor Solenoid
Component Identification

Model CM9HLB Shown Model CM2MRY Shown

K
F IG . 2
Key: A Ram Assembly B Air Motor C Displacement Pump D Platen F Remote DataTrak (single ram systems) or Display Module (tandem systems) G Integrated Air Controls (see FIG. 3) H Lift Ring J Platen Bleed Port K Power Supply Box (under shrouding) P Pump Bleed Valve R Enclosed Wet Cup S Fluid Line (not supplied, see FIG. 1) T Air Line (not supplied, see FIG. 1) U Air Line Drain Valve (not supplied, see FIG. 1) V Air Filter (not supplied, see FIG. 1)
W Bleed Type Air Shutoff Valve (not supplied, see FIG. 1) X Air Motor Solenoid
Component Identification · Lift Location

Air Line Accessories
See FIG. 1.
D200, D200s, D60, and S20 Models
The integrated air controls include:
D60i, D200i, and D200si Models
Units that have 2-Button Interlock controls have the fol- lowing additional components:


BE
F IG . 4
BD
BG

BB
BA
CB
FIG. 3. Integrated Air Controls
Component Identification · Activation Buttons


CD
F IG . 6
Key: CA Elevator Cart CB Air Motor CC Displacement Pump CD Platen CE Enclosed Wet Cup (behind air controls) CF Elevator and Pump Air Controls J Platen Bleed Port P Pump Bleed Valve
Component Identification · CM7B1G Model Shown · r_257032_312376_1e


Be sure all air hoses (T) and fluid hoses (S) are properly sized and pressure-rated for your system. Use only electrically conductive hoses. Fluid hoses must have spring guards on both ends. Use of a short whip hose and a swivel between the main fluid hose and the gun/valve allows freer gun/valve movement.
Component Identification

General Information
Pump: use a ground wire and clamp. Loosen grounding lug locknut and washer. Insert one end of supplied ground wire into slot in lug and tighten locknut securely. Connect other end of wire to a true earth ground. See FIG. 8.
Reference numbers and letters in parentheses in the text refer to the callouts in the figures.
Accessories are available from Graco. Make certain all accessories are adequately sized and pressure-rated to meet the system’s requirements.

FIG. 1, FIG. 2, and FIG. 6 are only guides for selecting and installing system components and accessories. Contact your Graco distributor for assistance in design- ing a system to suit your particular needs.
Location
Air and fluid hoses: use only electrically conductive hoses with a maximum of 500 ft. (150 m) combined hose length to ensure grounding continuity. Check elec- trical resistance of hoses. If total resistance to ground exceeds 29 megohms, replace hose immediately.
Always lift supply system at proper lift locations (see FIG. 1, FIG. 2, and FIG. 6). Do not lift in any other way.
Air compressor: follow manufacturer’s recommenda- tions.
Attach a lifting sling at the proper lift spots. Lift off the pallet using a crane or a forklift.
Spray gun/dispense valve: ground through connection to a properly grounded fluid hose and pump.
Position the ram so the air controls are easily accessi- ble. Ensure that there is enough space overhead for the ram to raise fully. (See Dimensions, page 34.)
Fluid supply container: follow local code.
Using the holes in the ram base as a guide, drill holes for 1/2 in. (13 mm) anchors.
Object being sprayed: follow local code.
Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive sur- face, such as paper or cardboard, which interrupts grounding continuity.
Ensure that the ram base is level in all directions. If nec- essary, level the base using metal shims. Secure the base to the floor using 1/2 in. (13 mm) anchors that are long enough to prevent the ram from tipping.
To maintain grounding continuity when flushing or relieving pressure: hold metal part of the dispense valve firmly to the side of a grounded metal pail, then trigger the valve.
The equipment must be grounded. Grounding reduces the risk of static and electric shock by provid- ing an escape wire for the electrical current due to static build up or in the event of a short circuit.
Installation

Attach 24V Class 2 power supply to terminals on the 24V assembly: +24 Vdc to terminal 2 (+) and -24 Vdc to terminal 5 (-). Attach protective earthing (PE) conductor
to terminal marked .


5 (-) 2 (+)
Quick disconnects restrict flow for large air motors.
The system has an IEC-C14 power input connection located on the back of the power supply box. The user must supply an appropriate adapter. The 100-240 Vac supply must be capable of sourcing at least 1.2 Amps and have supply current protection rated in accordance with the supply wire gauge provided.
The 24 Vdc supply must be capable of supplying at least 1.2 Amps and have supply current protection rated at no more than 2.5 Amps.
Voltage Max. Current
Frequency Voltage Max. Current Phase
24 Vdc 1.2 Amps
50-60 Hz 100-240 Vac 1.2 Amps 1
Have a trained electrician install and inspect power con- nection per local code.
Have a trained electrician install and inspect power con- nection per local code. Plug power supply cord into the outlet on the back of the power supply box and into a properly grounded electrical outlet. Use a zip tie, if needed, to secure power cord in place.

Installation · PE ti10853a

For supply systems with remote DataTrak, an optional kit can be purchased to indicate either when the drum is low or when it is empty. Order kit 255469 for a D60 or D200 3 in. ram, 255689 for a D200s 6.5 in. ram, or 257634 for a S20 3 in. ram.
For D60 supply systems: Flip actuator bracket (ED) so that it points upwards instead of downwards to allow it to pass the sensor (EE).

Light Tower Accessory
EE
Order the 255467 Light Tower Accessory as a diagnos- tic indicator for D200s, D200, D60, and S20 supply sys- tems. See TABLE 3 for a description of light tower signals.
EB


Red on The system is shut down due to error conditions.
ED
Installation

Only D200s, D200, and D60 Supply systems are shipped with drum stops in place to help position the drum on the ram. For replacement parts, order Kit 255477. The kit includes 2 each of capscrews (FA), lock washers (not shown), and drum stops (FB).

F IG . 11
D200 and D200s Base D60 Base
55 gal (200 L) 30 gal (115 L)
60 gal (16 L)
8 gal (30 L)
16 gal (60 L)
8 gal (30 L)
5 gal (20 L)
5 gal (20 L)
Installation

Flush Before Using Equipment
The pump was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid contaminat- ing fluid with oil, flush the pump with a compatible sol- vent before use. See pump manual for flushing directions.
a. Close the air motor slider valve (BF) and the main air slider valve (BA).
b. Set the ram director valve (BC) to DOWN. The ram will slowly drop.
Moving parts can pinch or amputate fingers. When the pump is operating and when raising or lowering the ram, keep fingers and hands away from the pump intake, platen, and lip of the drum.
c. Jog the director valve up and down to bleed air from ram cylinders.
a. Close the air motor valve (DC) and the elevator director valve (DD). The ram will slowly drop.
If you suspect that the spray tip/nozzle or hose is com- pletely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip/nozzle or hose.
To avoid damage to the platen seals, do not use a drum that is dented or damaged.
Supply System Operation

being trapped under the platen, scoop fluid from the center of the pail to the sides, to make the surface concave.


a. For S20 and D60: Set the director valve (BC) to DOWN and continue to lower the ram until fluid appears at the platen bleed port (J) and close the platen bleed port. Set the director valve to neutral, reinstall the vent handle, and tighten securely.
L20c 2 in. Elevator, S20 3 in. Single Post, and D60 3 in. Single Post
a. For S20 and D60: Open the main air slider valve (BA) and set the ram air regulator (BB) to 40 psi (0.28 MPa, 2.8 bar). Set director valve handle (BC) to UP and let the ram rise to its full height. 2-Button Interlock: If the system has this feature, ram will stop as it nears the top. Press and hold both buttons to raise ram com- pletely. See FIG. 3 on page 12.
b. For L20c: Turn elevator director valve (DD) to DOWN and continue to lower the ram until fluid appears at the platen bleed port (J). Close the platen bleed port (J).
b. For L20c: Set elevator director valve (DD) to UP and let the ram rise to its full height.
Supply System Operation

a. For D200s, D200, S20, and D60: Set ram director valve (BC) to UP to raise the platen (D) and immediately press and hold the blowoff air button (BG) until the platen (D) is completely out of drum. Use minimum amount of air pressure necessary to push the platen out of the drum.
Be sure all components are adequately sized and pressure rated to meet the system’s requirements.
b. For L20c: Set elevator director valve (DD) to UP to raise the platen (D) and immediately press and hold the blowoff air button (DB) until the platen (D) is completely out of drum.
Excessive air pressure in the material drum could cause the drum to rupture, causing serious injury. The platen must be free to move out of the drum. Never use drum blowoff air with a damaged drum.
Increase air pressure to the ram if the pump does not prime properly with heavier fluids. Decrease air pressure if fluid is forced out around the top seal or platen.
a. For D200s, D200, S20, and D60: Push in the air motor slider valve (BF) to stop the pump.
b. For L20c: Turn air motor valve (DC) off to stop the pump.
Supply System Operation

Remove wet cup from displacement pump while attached to the ram to replace throat seals.

GC GA
Supply System Operation


The remote DataTrak display unit comes fully assem- bled. Use the following instructions and figure to con- nect remote DataTrak to the supply system.
The system requires either 100-240 Vac, 50/60 Hz input, or 24 Vdc to the power supply. Ensure that the main disconnect rocker switch is set to OFF (O). Con- nect power to the DataTrak unit as detailed in Connect Remote DataTrak Units to Power, page 16.
The CAN cable (HB) can connect to either of the two CAN style connectors on the remote DataTrak.

Supply System Operation

Remote DataTrak Controls and Indicators
Key for FIG. 16
SC Display Screen LE LED (diagnostic indicator when lit) FR Flow Rate Units, user settable to:
PF Prime/Flush Key RK Reset/Cancel Key (also used to scroll) CF Cycle/Flow Rate JT Job Total Counter, resettable MC Maintenance Counter MS Maintenance Counter Setpoint DV Drum Volume Remaining DS Drum Size DF Drum Fill Volume RT Runaway Protection (enable/disable) RS Runaway Cycle Rate PV Displacement Pump Volume
= cycles per minute
gpm [US] = gallons per minute, United States gpm [UK] = gallons per minute, United Kingdom oz/min [US] = ounces per minute United States oz/min [UK] = ounces per minute United Kingdom l/min = liters per minute cc/min = cubic centimeters per minute VU Volume Units

JT
MC

LE
VU
CF
FR
SC; See Details at right.

RS
DS
RK PF
DF
PV
FIG. 16. Remote DataTrak Controls and Indicators
/min, · Run Mode · Setup Mode

Run Mode
To prevent damage to soft key buttons, do not press the buttons with sharp objects such as pens, plastic cards, or fingernails.
See FIG. 16 and FIG. 19.
The Run Mode screen displays the resettable job total counter (JT), maintenance counter (MC), cycle/flow rate (CF), and the remaining volume in the drum (DV) in both numeric and icon versions.
All items are displayed using the defined volume units (VU).


for 3 seconds.
release . The system will enter Diagnostic Mode only if there are active warnings/alarms.

Remote DataTrak Operation

If a password has been assigned (not set to ‘0000’), the Password screen will appear (FIG. 21). Enter the pass- word to access the Setup screens.
See FIG. 20.


Use Setup screen 1 to set runaway cycle rate (RS), enable/disable runaway protection (RT), select pump volume per cycle (PV), select flow rate units (FR), enter drum size (DS), and enter drum fill volume (DF). See FIG. 22.
If a key is not pressed within one minute of entering a setup screen, the system will return to Run Mode (FIG. 19).
If you go past a field you want to edit, toggle through the remaining fields, exit the Setup mode, and reenter Setup. It is impossible to back up in the Setup screens.
See FIG. 16. Press and hold for 3 seconds.
Remote DataTrak Operation

Runaway Cycle Rate/Enable Runaway Protection
RT

Graco recommends setting runaway cycle rate (RS) to 60 or less. Choose a value that is just above the maxi- mum cycle rate of the application.
When runaway protection is enabled (RT), a ✓ will appear on the setup screen. See FIG. 22.
PV
Press to scroll through the available displace- ment pump volumes (PV) in cc per cycle. set the values to the pump size installed. Refer to manual 312375 or the marking on the displacement pump cylinder.
Use Setup screen 2 to set the maintenance counter set- point (MC), reset the maintenance counter, enable/dis- able diagnostic codes (EC), and choose whether the E7 drum icon (DL) will indicate when the drum is low or when the drum is completely empty.
Press to scroll through the available flow rate units. See Key on page 24. The selected units will be used to display flow rate and volume on the main Run screen and most of the setup values.

Initially, choose units that will allow easy definition of the setup values (e.g. drum volume in gallons). Then, return and select the flow rate unit to display on the Run screen. The defined setup values will convert automatically.
Use DS to enter the size of the container.
Use the Drum Fill Volume field (DF) to enter the exact volume of material in the drum. Contact sup- plier for exact volume. This value is used to deter- mine the remaining volume in the drum.
Drum Fill Volume field (DF), then press once more.
Use the maintenance counter setpoint (MS) to set the maintenance schedule based on the units dis-
played. Press and hold for 3 seconds when the entire MS field is highlighted to reset the MC value.

When E1, E2, and E4 diagnostic options are enabled, a ✓ will appear on the setup screen. See FIG. 23.
The screensaver turns off the backlight of the LCD after the specified time has elapsed. A setting of 0 minutes is not recommended because it turns off the screensaver, leaving the backlight on con- stantly.
Drum Low/Empty Diagnostic Code
The E7 drum icon can represent either a drum low or a drum empty.
Drum Low: A drum low setting will result in a warn- ing condition. The icon will show as an almost empty drum. The light tower and diagnostic LED will signal a warning. The pump will continue to cycle.
When in the contrast setting field press to adjust the contrast + (up) or - (down) respectively.
Drum Empty: A drum empty setting will result in an alarm condition. The icon will show as a completely empty drum. The light tower and diagnostic LED will signal an alarm. The pump will stop cycling.
contrast setting, then press once more. If you entered Setup Mode from Prime Mode, you will be returned to that screen.
Press while E7 is selected to toggle between these options.
drum setting, then press once more.
Setup screen 3 displays a non-resettable grand total counter (GT) at the top. Use Setup screen 3 to set the password (PW), assign a time limit for the screensaver (SS), and adjust the LCD contrast (CS).

Remote DataTrak Operation

a. Press and release to enter Diagnostic Mode from Run Mode (FIG. 19).
Remote DataTrak can diagnose several problems with the supply system. When the monitor detects a problem, the LED (B, FIG. 16) will flash and a diagnostic code will appear on the display. See Table 4, page 33.
b. Press and release to scroll to the Runaway Diagnostic screen, or return to the previous Run screen if no other Diagnostic screens are active.
If the accessory light tower kit is installed a light will illu- minate or flash on the tower. See TABLE 4.
c. Press and hold for 3 seconds while on the runaway Diagnostic screen to clear the diag- nostic code and scroll to the next available Diagnostic screen, or return to the previous Run screen if no other Diagnostic screens are active.
Diagnostic screens will become the active screen as soon as the diagnostic code condition is detected. See TABLE 4.
To acknowledge the diagnosis and return to the normal
operating screen, press once. To clear a diagnostic code, see the section specific to the code.
See FIG. 16. Press and release to access the Diag- nostic screens. The system will enter Diagnostic Mode only if active warnings/alarms are present.
To disable runaway monitoring, go to setup mode and set runaway value to 0 (zero) or toggle (RT) off. See FIG. 22.
See FIG. 25. If pump runaway occurs, the Runaway screen becomes active, stopping the pump.

Remote DataTrak Operation

Diving Down Diagnostic Code Screen
See FIG. 26. If the pump shows diving up symptoms and the E1 Diagnostic Code is enabled, the Diving Up screen becomes active.
See FIG. 27. If the pump shows diving down symptoms and the E2 Diagnostic Code is enabled, the Diving Down screen becomes active.


a. Press and release to enter Diagnostic Mode from Run Mode.
a. Press and release to enter Diagnostic Mode from Run Mode.
b. Press and release to scroll to the Diving Down Diagnostic screen, or return to the previ- ous Run screen if no other Diagnostic screens are active.
b. Press and release to scroll to the Diving Up Diagnostic screen, or return to the previous Run screen if no other Diagnostic screens are active.
c. Press and hold for 3 seconds while on the Diving Down Diagnostic Screen to clear the diagnostic code and scroll to the next available Diagnostic screen, or return to the previous Run screen if no other Diagnostic screens are active.
c. Press and hold for 3 seconds while on the Diving Up Diagnostic screen to clear the diag- nostic code and scroll to the next available Diagnostic screen, or return to the previous Run screen if no other Diagnostic screens are active.
Remote DataTrak Operation

Drum Low/Empty Diagnostic Code Screen
See FIG. 29 and FIG. 30. If the drum low/empty sensor trips, the Drum Low or Drum Empty screen becomes active, depending on which sensor setting is chosen, see page 28.
See FIG. 28. If the system detects a disconnected air motor solenoid and the E4 Diagnostic Code is enabled, the Disconnected Solenoid screen becomes active.



FIG. 30. Drum Low Diagnostic Code Screen
Remote DataTrak Operation

Maintenance Counter Expired Screen
See FIG. 31.
See FIG. 32.
If the system detects an air motor reed switch error, the Reed Switch Diagnostic screen becomes active.
If the system has counted down to 0 from the setpoint for number of cycles/gallons/liters, the Maintenance Counter Expired Screen becomes active.


FIG. 32. Maintenance Counter Expired Screen
FIG. 31. Reed Switch Diagnostic Code Screen
a. Press and release to enter Diagnostic Mode from Run Mode.
b. Press and release to scroll to the Reed Switch Diagnostic screen, or return to the previ- ous Run screen if no other Diagnostic screens are active.
c. Press and hold for 3 seconds while on the Reed Switch Diagnostic Screen to clear the diagnostic code and scroll to the next available Diagnostic screen, or return to the previous Run screen if no other Diagnostic screens are active.
Remote DataTrak Operation

No. Code Name Diagnosis Cause
Runaway Pump running faster than set runaway limit.
E1 Diving Up Leak during upstroke. Worn piston valve or packings.
E2 Diving Down Leak during downstroke. Worn intake valve or priming rod seal.
E7 Drum Empty Drum empty sensor has tripped.
Replace empty drum with full drum to clear.
E7 Drum Low Drum low sensor has tripped. Replace empty drum with full drum to clear.
E5 Reed Switch The air motor has seen multiple up strokes without a down stroke, or vice versa.
Damaged or disconnected reed switches.
Maintenance Counter has counted down to 0 from setpoint.
Number of cycles/gallons/liters specified by setpoint have passed since last reset.
*LED (B, page 24) will flash a code, pause, then repeat.


Dimensions



L20c 69 (1752.6) 44 (1117.6) 21 (533.4) 22 (558.8)
S20 (NXT) 84 (2133.6) 59 (1498.6) 16 (406.4) 19 (482.6) 11 (279.4) 17 (431.8)
S20 59.3 (1506) 35.8 (909) 16 (406.4) 19 (482.6) 11 (279.4) 17 (431.8)
S20c 90 (2286) 65 (1651) 26.0 (661) 22.1 (562)
D60 89 (2260.6) 59 (1498.6) 14 (355.6) 18 (457.2) 24 (609.6) 28 (711.2)
D200 102.3 (2599) 64.8 (1646) 21.0 (533) 25.0 (635) 38.0 (965) 42.0 (1067)
D200s 109 (2769) 68.2 (1732) 23.0 (584) 25.0 (635) 45.0 (1143) 48.0 (1219)
See the identification plate (ID) for the weight of your supply system.
Use the table below to identify the maximum weight for each available platen size.


Dimensions

(6) (5) (5) Reed Switch Com
REED SWITCH
(GND) UNUSED
DRUM LOW
LIGHT TOWER
(3) COM
(1) UNUSED
(5) UNUSED
(4) AMBER
(2) RED
(3) COM
(1) N/C
(2) N/C
ADAPTER CABLE
F M
F M
Amber (2) Common (14)
Air Solenoid (4) Common (16)
Top Motor Reed (6) Common (18)
Bottom Motor Reed (19)
Drain (21) N/C (8)
N/C (23) N/C (10)
N/C (11)
N/C (12) N/C (24)
N/C (13) N/C (25)
LOCAL CONTROL MONITOR,
SHLD (1)
-24Vdc (3) +24Vdc (2)
CAN_L (5)
REMOTE DATATRAK
-24Vdc (3) +24Vdc (2)
SHLD (1)
CAN_L (5)
+24VDC POWER
SUPPLY
-24Vdc +24Vdc SHLD L

Point of Operation Instructions
For use with non-heated bulk supply of medium to high viscosity sealants and adhesive materials. Not for use in hazardous locations.
Safety Practices: The instruction on this sheet are abbreviated and are provided only as a customer service. They are not meant to replace the Operation Manual. If you are unsure of the equipment’s safe and proper operation, request Graco Operation Manual 313526. It is important that you read and understand all instructions and hazards before operating this equipment.
SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treat- ment.
Moving parts can pinch or amputate fingers. When the pump is operating and when raising or lowering the ram, keep fingers and hands away from the pump intake, platen, and lip of the drum.
MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts.
SPLATTER HAZARD During blowoff of platen splatter may occur.
To avoid damage to the platen seals, do not use a drum that is dented or damaged.

D200S, D200, S20, and D60 Supply Systems Point of Operation Instructions
Change Drums
Keep hands and fingers away from the priming piston during operation and whenever the pump is charged with air. Follow Pressure Relief Procedure before checking, clearing, or cleaning the priming piston.
Excessive air pressure in the material drum could cause the drum to rupture, causing serious injury. The platen must be free to move out of the drum. Never use drum blowoff air with a damaged drum.
To reduce the risk of fluid injection, do not use your hand or fingers to cover the bleed hole on the under- side of the bleed valve body when priming the pump. Use the handle or a crescent wrench to open and close the bleed plug.
a. When a new drum is installed, press and hold
while in Prime Mode to reset the drum vol- ume remaining to the drum fill volume.
Always use lowest possible fluid pressure to bleed air out of pump.
b. To exit Prime Mode, press . The Prime sym- bol will disappear and the LED will stop flashing; the screen will return to Run Mode.

Point of Operation Instructions
For use with non-heated bulk supply of medium to high viscosity sealants and adhesive materials. Not for use in hazardous locations.
Safety Practices: The instruction on this sheet are abbreviated and are provided only as a customer service. They are not meant to replace the Operation Manual. If you are unsure of the equipment’s safe and proper operation, request Graco Operation Manual 313526. It is important that you read and understand all instructions and hazards before operating this equipment.
SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treat- ment.
Moving parts can pinch or amputate fingers. When the pump is operating and when raising or lowering the ram, keep fingers and hands away from the pump intake, platen, and lip of the drum.
MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts.
SPLATTER HAZARD During blowoff of platen splatter may occur.
To avoid damage to the platen seals, do not use a drum that is dented or damaged.

L20c Supply Systems Point of Operation Instructions
Change Drums
Keep hands and fingers away from the priming piston during operation and whenever the pump is charged with air. Follow Pressure Relief Procedure before checking, clearing, or cleaning the priming piston.
Excessive air pressure in the material drum could cause the drum to rupture, causing serious injury. The platen must be free to move out of the drum. Never use drum blowoff air with a damaged drum.
To reduce the risk of fluid injection, do not use your hand or fingers to cover the bleed hole on the under- side of the bleed valve body when priming the pump. Use the handle or a crescent wrench to open and close the bleed plug.
Always use lowest possible fluid pressure to bleed air out of pump.

Max air input pressure (supply system) / Air inlet size
L20c - 2 in. elevator, 5 gal. (20 L) 100 psi (0.7 MPa, 7 bar) / 1/2 npsm(f) S20 - 3 in. single post, 5 gal. (20 L) 125 psi (0.9 MPa, 9 bar) / 1/2 npt(f) D60 - 3 in. dual post, 16 gal. (60 L), 5 gal. (20 L), 30 gal. (115 L) 150 psi (1.0 MPa, 10 bar) / 3/4 npt(f) D200 - 3 in. dual post, 55 gal. (200 L), 30 gal. (115 L), 16 gal. (60 L), 8 gal. (30 L), 5 gal. (20 L) 150 psi (1.0 MPa, 10 bar) / 3/4 npt(f) D200s - 6.5 in. dual post, 55 gal. (200 L), 30 gal. (115 L) 125 psi (0.9 MPa, 9 bar) / 3/4 npt(f)
Max fluid, air working pressure. and weight (displacement pump)
For Check-Mate pump packages, see manual 312376. For Dura-Flo pump packages, see manuals 311826, 311828, 311833. Pump Wetted parts For Check-Mate displacement pumps, see manual 312375. For Dura-Flo displacement pumps, see manuals 311717, 311825, 311827. Platen Codes (see page 7) : Part number; Wetted parts
B : 257727, 5 gal. (20 L) J : 257732, 8 gal. (30 L) S : 257737, 16gal. (60 L)
Electroless nickel, polyurethane, nitrile, carbon steel, polyethylene, zinc plated carbon steel, buna, 316 sst, 17-4PH sst
C : 257728, 5 gal. (20 L) K: 257733, 8 gal. (30 L) T: 257740, 16gal. (60 L)
Electroless nickel, polyurethane, carbon steel, polyeth- ylene, nitrile, zinc plated carbon steel, buna, 316 sst 17-4PH sst
F : 257729, 5 gal. (20 L) L : 257734, 8 gal. (30 L) U : 257738, 16gal. (60 L)
Stainless steel, polyurethane, PTFE coated nitrile, poly- ethylene, nitrile, PTFE, 303 sst, 304 sst, 316 sst, 17-4PH sst
G : 257730, 5 gal. (20 L) M : 257735, 8 gal. (30 L) W : 257739, 16gal. (60 L)
Electroless nickel, aramind reinforced elastomer, rub- ber-based PSA, nitrile, polyethylene, zinc plated carbon steel, buna, 1018 carbon steel, 304 sst, 316 sst, 17-4PH sst
H : 257731, 5 gal. (20 L) R : 257736, 8 gal. (30 L) Y : 257741, 16gal. (60 L
Electroless nickel, aramind reinforced elastomer, rub- ber-based PSA, polyurethane, polyethylene, nitrile, zinc plated carbon steel, buna, 1018 carbon steel, 304 sst, 316 sst, 17-4PH sst
7 : 255661, 30 gal. (115 L) zinc plated carbon steel, EPDM, sst, fluoroelastomer 8 : 255662, 55 gal. (200 L) PTFE, EPDM, PTFE coated aluminum, zinc plated carbon steel, 316 sst 9 : 255663, 55 gal. (200 L) EPDM, aluminum, zinc plated carbon steel, 316 sst A : 255664, 55 gal. (200 L) PTFE, neoprene, aluminum, zinc plated carbon steel, 316 sst
Ambient operating temperature range (supply system) 32-120 °F (0- 49°C) Sound data See separate air motor manual. External power supply requirements (DatraTrak)
AC power units 100-240 Vac, 50/60 Hz, single phase, 1.2 amps max draw DC power units 24 Vdc, 1.2 amps max draw
Technical Data

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
Original instructions. This manual contains English. MM 313526
www.graco.com Revision V, March 2014