Instruction/ maintenance manual of the product 309489E Graco
Go to page of 20
Instructions–Parts List 309489E ENG Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. President 10:1 Ratio Air Spray System For transfer or supply of compatible fluids. With Evenflo r Automatic Pressure Control Model 954088, Series A 180 psi (12 bar , 1.
2 309489 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . . . . . . . . . .
3 309489 W ARNING SKIN INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
4 309489 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury . Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
5 309489 Installation General Information NOTE: Reference numbers and letters in parentheses refer to callouts in the Figs. and parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor . Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below .
6 309489 Installation NOTE: Reference numbers and letters in parentheses in the text refer to callouts in the figure illustrations and the parts drawing. The T ypical installation shown on page 7 is only a guide to electing and installing required and optional accessories.
7 309489 Installation T ypical Installation ti3003c KEY A B C D E H J K L M 38 52 1/2” Minimum A L C 38 E D J B H K 52 M Evenflo R Air Regulator Bleed-T ype Master A ir V alve Pump Runaway V alve Ai.
8 309489 Operation Pressure Relief Procedure With the Evenflo control, its bypass valve, and the pump Relax-A-V alve properly set, fluid pressure is relieved from the pump and hose each time you re- lease the gun trigger . Always engage the gun trigger safety when you stop spraying.
9 309489 Operation Use the air regulator (A) to control fluid pressure and pump speed. Always use the lowest pressure neces- sary to get the desired results. Higher pressures cause premature pump wear and spray tip wear , and usually do not improve the spray pattern.
10 309489 Maintenance Lubrication If your system includes an automatic air line lubricator , adjust the lubricator as instructed in the separate instruction manual. For manual lubrication, each day , remove the air inlet hose and place 12 to 15 drops of high quality , light motor oil in the inlet.
11 309489 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Relieve the pressure before you check or service any system equipment. NOTE: Check all possible problems and solutions before disassembling the pump.
12 309489 Service Displacement Pump Repair Before you start: 1. A packing repair kit, part no. 946761 is available. This kit includes two glands and eight packings for the motor as well as o-rings, packings, and wash- ers for the displacement pump. For the best re- sults use all the parts in the kit.
13 309489 Fig. 4 Fig. 5 06703 15 4 2 8 19 3/16” Piston Ball T ravel T orque to 100–150 ft-lb (136–204 N m) 1 43 30 31 32 34 35 33 50 2 3* 45 1 44 4 6 *8 7 *8 39 9 28 37 5 10* 12 14 15 16 17 .
14 309489 Parts 43 30 31 32 34 35 33 50 2 3* 45 1 44 4 6 *8 7 *8 39 9 28 37 5 10* 12 14 15 16 17 20 18* 19 22* 18* 20 21 *1 1 13 25 *23 26 27 24 52 53 46 48 47 51 42 29 36 49 38 17489a.
15 309489 Parts Model 954088, Series A Includes items 1–53 Ref. No. Part N o. Description Qty . 1 100016 W ASHER, lock 2 2 621201 STUD, clamp 1 3* 510636 PIN, spring, str 1 4 620850 ROD, connecting .
16 309489 T echnical Data Fluid pressure ratio 10:1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air pressure operating range 40–180 psi (3–12 bar) .
17 309489 Dimensions 1” (25.4 mm) 1–1/4” (31.8 mm) 14–1/2” (368.3 mm) 6–3/4” (171.4 mm) 3/8 npt 1 1/16” (17.5 mm) OD 45 45 6–1/2” (165.
18 309489 Dimensions 17488a 53–3/4” (1365.3 mm) 2–1/4” (47.2 mm) 39–1/4” (997 mm) 4” (101.6 mm) Model 954088, Series A Weight: 40 lb (18 Kg) 3/8 npsm Height of 55 gallon drum 34–3/4 (8.
19 309489 Notes.
20 309489 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
An important point after buying a device Graco 309489E (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco 309489E yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco 309489E - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco 309489E you will learn all the available features of the product, as well as information on its operation. The information that you get Graco 309489E will certainly help you make a decision on the purchase.
If you already are a holder of Graco 309489E, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco 309489E.
However, one of the most important roles played by the user manual is to help in solving problems with Graco 309489E. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco 309489E along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center