Instruction/ maintenance manual of the product 307614 Graco
Go to page of 16
307614 Rev . R First choice when quality counts. INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE.
2 307614 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation/Operation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . System Requirements 5 . . . . . . . . . . . . . . . . . .
307614 3 TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. Know the specific hazards of the fluid you are using. Store hazardous fluid in an approved container .
4 307614 EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury . This equipment is for professional use only . Read all instruction manuals, tags, and labels before operating the equipment.
307614 5 Installation/Operation System Requirements W ARNING Keep the wallet-sized warning card provided with this gun with the operator at all times. The card contains important treatment information should an injection injury occur . Additional cards are available at no charge from Graco Inc.
6 307614 Installation/Operation How to Use the Gun 1. Connect a grounded fluid hose to the gun inlet. See Fig. 2 2. With no tip installed, start the pump. Flush the pump according to the instructions supplied with it. Prime the system with the fluid. 3.
307614 7 Installation/Operation How to Clean the Spray Tip and Clear a Spray Tip Obstruction W ARNING T o reduce the risk of fluid injection or splashing in the eyes or on the skin, do not hold a hand, body or rag in front of the spray tip when cleaning or checking a clogged tip.
8 307614 Installation/Operation How to Check the Gun Diffuser Operation Check the diffuser operation weekly . The gun diffuser/ seat (A) breaks up spray and reduces the risk of fluid injection when the tip is not installed. Perform the test below . If it fails, replace the entire Needle Kit, Part No.
307614 9 Installation/Operation How to Flush the Gun W ARNING T o reduce the risk of serious bodily injury , including splashing fluid in the eyes or on the skin, or static electric discharge when flushing: Be sure the entire system, including flushing pails, are properly grounded.
10 307614 Service Fig. 7 23 1 2 T orque to 26 – 32 ft- lb (35 – 43 N.m) A B C D 1 4 T orque to 80 – 90 in-lb (9 – 10 N.m) NOTE: The needle (C), diffuser/seat (A), gasket (B) and locknut (D) must be replaced together . They are included in Kit 218070.
307614 11 Notes.
12 307614 Parts Drawing 03013 41 40 3 2 12 5 4 6 13 14 15 16 20 19 18 21 22 23 26 32 37 1 31 33 1 Included with 1 Model 220955, Series D Includes items 1 and 4 to 41 Model 235990, Seri.
307614 13 Parts List Model 220955, Series D; Model 235990, Series C; Model 217593, Series E; Model 820165, Series D Ref. No. Part N o. Description Qty .
14 307614 Accessories FIL TERS 3000 psi (210 bar , 21 MPa) Maximum Working Pressure. Adequate filtering is important for a good surface finish and to minimize tip clogging. These filters provide secondary filtering. Elements are available in various mesh sizes.
T echnical Data Maximum Working Pressure 3600 psi . . . . . . . . . . . . . . (252 bar , 25.2 MPa) Fluid Orifice Size 0.125 in. (3.18 mm) . . . . . . . . . . . . . . . Wetted Parts Stainless steel, Polyethylene, . . . . . . . . . Polyurethane, Nylon, PTFE Weight 18 oz.
16 307614 Graco W arranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
An important point after buying a device Graco 307614 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco 307614 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco 307614 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco 307614 you will learn all the available features of the product, as well as information on its operation. The information that you get Graco 307614 will certainly help you make a decision on the purchase.
If you already are a holder of Graco 307614, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco 307614.
However, one of the most important roles played by the user manual is to help in solving problems with Graco 307614. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco 307614 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center