Operation

Fine Finish Hand-Held Paint Sprayer

EN

- For portable spray applications of architectural paints and coatings only -

- Not approved for use in explosive atmosphere locations -

- Service only at Graco approved service centers -

- For professional use only -

Graco 262612 — EN diagram (page 1)
Fig. 1
All ModelsMaximum Working Pressure 1700 psi (117 bar, 11.7 MPa)
Graco 262612 — EN diagram (page 1)
Fig. 2
Model 16F887✓ 16H240✓ 16H241✓✓ 16H242✓✓ 16H243✓ 262612✓ 16H245✓ 16H829✓
Page 3 of the Graco 262612 user manual — Grounding Wire Repair
Page 3 · click to enlarge
Page 3

Warnings

The following warnings are for the setup, use, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these sym- bols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD (GROUNDING) Some oil-based and flammable materials generate static electricity when sprayed. Static electricity creates an explosion and fire risk. Your sprayer has a grounding cord that will conduct the static electricity to a grounded electrical outlet. The sprayer and all objects in spray area shall be properly grounded to protect against static discharge, sparks or shocks.

  • Connect the grounding cord when spraying flammable or static producing oil-based materials.
  • If there is static sparking or if you feel a shock, stop spraying immediately and connect the sprayer to a properly grounded electrical outlet with the ground wire provided.

GROUNDING INSTRUCTIONS

Move the sprayer away from the spray area to a non-hazardous location. Plug the ground wire into the sprayer.

Unwind the ground wire from the spool and plug it into a properly grounded electrical outlet.

If the ground wire is not long enough to reach a grounded electrical outlet, a 3-wire grounded extension cord may be used to reach a grounded outlet.

Grounding Wire Repair

If the grounding wire breaks at the spool end, perform the following steps:

If the grounding wire breaks at the grounding plug, perform the following steps:

1. Unwind wire from grounding spool and use a flat screwdriver to pry apart the grounding spool.
1. Pull rubber boot off of wire at grounding plug and slide boot over grounding wire.
Graco 262612 — Grounding Wire Repair diagram (page 3)
Fig. 3 · Grounding Wire Repair
2. Loosen screw on terminal and remove broken wire. Strip insulation from grounding wire, insert into terminal and tighten screw.
2. Loosen screw and remove broken wire. Insert stripped grounding wire and tighten screw.
3. Replace rubber boot onto grounding plug.
Page 4 of the Graco 262612 user manual — WARNING WARNING WARNING WARNING
Page 4 · click to enlarge
Page 4

WARNING

  • FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
  • Do not spray flammable or combustible liquids in a confined area.
  • Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.
  • Paint or solvent flowing through the sprayer is able to result in static electricity. Static electricity creates a risk of fire or explosion in the presence of paint or solvent fumes. The sprayer and all objects in spray area shall be properly grounded to protect against static discharge, sparks, or shocks.
  • Always connect the grounding cord provided when spraying flammable materials or static producing oil-based materials. See Grounding Instructions , page 3.
  • If there is static sparking or you feel a shock, stop operation immediately and connect sprayer to a properly grounded electrical outlet with the ground wire provided.
  • Do not spray flammable or combustible materials near open flame or sources of ignition such as cigarettes, external motors, and electrical equipment.
  • Do not operate light switches, engines, or similar spark producing products in the spray area.
  • Do not smoke in the spray area.
  • Keep spray area clean and free of paint or solvent containers, rags, and other flammable materials.
  • Know the contents of the paints and solvents being sprayed. Read all Material Safety Data Sheets (MSDS) and container labels provided with the paints and solvents. Follow the paint and solvents manufacturer’s safety instructions.
  • Fire extinguisher equipment shall be present and working.
  • SKIN INJECTION HAZARD High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection occurs, get immediate surgical treatment .
  • Do not aim the sprayer at, or spray any person or animal.
  • Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.
  • Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.
  • Always use the spray tip guard. Do not spray without spray tip guard in place.
  • Use caution when cleaning and changing spray tips. In the case where the spray tip clogs while spraying, follow the Pressure Relief Procedure for relieving the pressure before reversing or removing the spray tip to clean.
  • Do not leave the unit energized or under pressure while unattended. When the unit is not in use, follow the Pressure Relief Procedure and engage the trigger lock.
  • Check parts for signs of damage. Replace any damaged parts with genuine Graco parts.
  • This system is capable of producing 1700 psi. Use replacement parts or accessories that are rated a minimum of 1700 psi.
  • Do not carry the sprayer with a finger on the trigger.
  • Verify that all connections are secure before operating the unit.
  • Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls.
Page 5 of the Graco 262612 user manual — WARNING WARNING WARNING WARNING
Page 5 · click to enlarge
Page 5

WARNING

  • EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury.
  • Disconnect the battery before servicing.
  • Always wear appropriate gloves, eye protection, and a respirator or mask when painting.
  • Do not operate or spray near children. Keep children away from equipment at all times.
  • Do not overreach or stand on an unstable support. Keep effective footing and balance at all times.
  • Stay alert and watch what you are doing.
  • Do not operate the unit when fatigued or under the influence of drugs or alcohol.
  • Use only in dry locations. Do not expose to water or rain.
  • Use in well-lit areas.
  • Always replace cracked, broken or missing parts immediately with genuine Graco parts. See Parts List, page 19.
  • BATTERY HAZARD The battery may leak, explode, cause burns, or cause an explosion if mishandled. Contents of an open battery can cause severe irritation and/or chemical burns. If on skin, wash with soap and water. If in eyes, flush with water for at least 15 minutes and get immediate medical attention.
  • Replace battery only in a well-ventilated area and away from flammable or combustible materials, including paints and solvents.
  • When battery is not in use, keep it away from metal objects like keys, nails, screws or other metal objects that can short circuit the battery terminals.
  • When spraying flammable materials, use only Graco SlimLine battery 16G610. Do not use Graco premium battery 16D558 when spraying flammable material.
  • Do not throw into fire.
  • Charge only with Graco approved charger as listed in this manual.
  • Do not store at temperatures below 32° or above 113°F (0° to 45°C).
  • Do not use at temperatures below 40° or above 90° F (4° to 32°C).
  • Do not expose battery to water or rain.
  • Do not disassemble, crush, or penetrate the battery.
  • Do not use or charge a battery that is cracked or damaged.
  • Follow local ordinances and/or regulations for disposal.
  • CHARGER ELECTRIC SHOCK, FIRE AND EXPLOSION HAZARD Improper setup or usage can cause electric shock, fire, and explosion.
  • Charge only in a well-ventilated area and away from flammable or combustible materials, including paints and solvents.
  • Do not charge on a combustible or flammable surface.
  • Do not leave battery unattended while charging.
  • Immediately unplug charger and remove battery when charging is complete.
  • Charge only Graco approved batteries listed in this manual; other batteries may burst.
  • Use only in dry locations. Do not expose to water or rain.
  • Do not use a charger that is cracked or damaged.
  • If the supply cord is damaged, replace the charger or cord, depending on model.
  • Never force the battery into the charger.
  • When operating a charger outdoors, always provide a dry location and use an extension cord suitable for outdoor use.
  • Disconnect the charger from the outlet before cleaning.
  • Ensure that the outside surface of the battery is clean and dry before plugging into the charger.
  • Do not attempt to charge non-rechargeable batteries.
  • Do not disassemble the charger. Take charger to authorized service center when service or repair is required.
Page 6 of the Graco 262612 user manual — PERSONAL PROTECTIVE EQUIPMENT
Page 6 · click to enlarge
Page 6

WARNING

PRESSURIZED ALUMINUM PARTS HAZARD

  • Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.
  • Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents.
  • Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for compatibility.
  • TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
  • Read MSDS’s to know the specific hazards of the fluids you are using.
  • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

PERSONAL PROTECTIVE EQUIPMENT

  • You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This equipment includes but is not limited to:
  • Protective eyewear, and hearing protection.
  • Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.
Page 7 of the Graco 262612 user manual — Component Identification
Page 7 · click to enlarge
Page 7

Component Identification

Graco 262612 — Component Identification diagram (page 7)
Fig. 4 · Component Identification

A Fine Finish Tip/Guard Assembly *B Tip Filter (Reverse Threaded) C Flexible Suction Tube D Pressure Control Knob E Prime/Pressure Relief Valve F Grounding Plug G SlimLine Battery H Battery Release Button J Indicator Light K Trigger

L Trigger Lock M Static Wick N Hi/Lo Switch (Motor Speed) P Outlet Valve Access Plug Q Startup/Storage Kit R Lithium Ion Battery Charger S Cup Liner Replacement (10 Pack) T Cup Lid W Storage Case

*NOTE: Tip filter is reverse-threaded. Turn left (or counter-clockwise) to tighten, turn right (or clockwise) to loosen.

Component Identification

Page 8 of the Graco 262612 user manual — Sprayer Status Indicator
Page 8 · click to enlarge
Page 8

Charging the Battery

Graco 262612 — Charging the Battery diagram (page 8)
Fig. 5 · Charging the Battery
3. When battery becomes fully charged, immediately unplug the charger from the power supply and remove the battery from the charger.

Replace and charge battery only in a well-ventilated area and away from flammable or combustible materials, including paints and solvents.

Batteries are initially 50% charged to provide optimum bat- tery life and require charging before first use. It takes approximately 25 minutes to charge a dead battery to 80%, at which point it can be used. It will take approximately 40 minutes to fully charge a dead battery.

1. Place charger in a dry, well-ventilated area and away from flammable or combustible materials, including paints and solvents.
2. Plug charger into an electrical outlet and slide battery into charger as shown (light will turn on in 5 seconds).

Charger Status Indicator Lights

Graco 262612 — Charger Status Indicator Lights diagram (page 8)
Fig. 6 · Charger Status Indicator Lights
LabelAppearanceDescription Solid green lightIndicates a full charge. Battery can be used. Flashing green lightBattery is charging, indicates 80% charge. Battery can be used. Flashing red lightBattery is charging, indicates less than 80% charge. Do NOT use battery. Solid red lightBattery is too hot or too cold to charge. Remove battery and allow to cool or warm up before charging.

Sprayer Status Indicator

Graco 262612 — Sprayer Status Indicator diagram (page 8)
Fig. 7 · Sprayer Status Indicator
Light*AppearanceDescription No light i16707a Solid red Flashing redNormal operation. t Battery is low on power and needs to be charged, or battery is too cold and must warm up before spraying. Battery temperature is too high, or tip is clogged. See Troubleshooting, page 26.

*NOTE: The sprayer status indicator light is visible for 10 seconds after the trigger is released.

Charging the Battery

Page 9 of the Graco 262612 user manual — Trigger Unlocked
Page 9 · click to enlarge
Page 9

Common Procedures

Trigger Lock

Pressure Relief Procedure

Always engage the trigger lock when you stop spraying to prevent the sprayer from being triggered accidentally by hand, or if dropped or bumped.

Do not operate or spray near children. Do not aim the sprayer at, or spray any person or animal. Keep hands and other body parts away from the front of the sprayer. For example, do not try to stop the paint flow with any part of the body.

This sprayer builds up an internal pressure of 1,700 psi during use. Follow this Pressure Relief Procedure whenever you stop spraying and before cleaning, checking, servicing, or transporting equipment to prevent serious injury.

4. Engage trigger lock.

Trigger Locked

5. Put prime/pressure relief valve UP to release pressure.

Trigger Unlocked

(red ring is visible)

Prime/Pressure Relief Valve Position

Spray Tip Position

Graco 262612 — Trigger Unlocked diagram (page 9)
Fig. 8 · Trigger Unlocked
Graco 262612 — Trigger Unlocked diagram (page 9)
Fig. 9 · Trigger Unlocked

Always perform Pressure Relief Procedure before adjusting spray tip position.

DOWN position (Ready to spray) ti14999a

UP position (For priming and releasing

Common Procedures · pump pressure)

Page 10 of the Graco 262612 user manual — Adjusting Pressure
Page 10 · click to enlarge
Page 10

Adjusting Pressure

Graco 262612 — Adjusting Pressure diagram (page 10)
Fig. 10 · Adjusting Pressure
1. To reduce overspray, always spray at lowest pressure that results in an acceptable spray pattern.
2. Spray test pattern and adjust pressure to get desired coverage.
1. To extend battery life, try spraying with low motor speed to get an acceptable spray pattern.
3. With some materials, if pressure is set too low, no material may spray out. Turn pressure control up.
2. Shift to high speed if needed to achieve an acceptable spray pattern.

Common Procedures

Page 11 of the Graco 262612 user manual — Spraying Ceilings, Walls and Crown Molding
Page 11 · click to enlarge
Page 11

Setup

Spraying Floors and Base Boards

Graco 262612 — Spraying Floors and Base Boards diagram (page 11)
Fig. 11 · Spraying Floors and Base Boards

When spraying floors, rotate the suction tube collar to the back of the material cup.

Graco 262612 — Spraying Floors and Base Boards diagram (page 11)
Fig. 12 · Spraying Floors and Base Boards

Flammable fumes (such as solvent and paint fumes) in work area can ignite or explode.

Do not spray flammable or combustible liquids in a con- fined area.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.

Graco 262612 — Spraying Floors and Base Boards diagram (page 11)
Fig. 13 · Spraying Floors and Base Boards
Graco 262612 — Spraying Floors and Base Boards diagram (page 11)
Fig. 14 · Spraying Floors and Base Boards

Flexible Suction Tube

This sprayer comes with a suction tube that can be adjusted for multi-directional spraying.

Spraying Ceilings, Walls and Crown Molding

When spraying ceilings or walls, rotate the suction tube collar to the front of the material cup.

Graco 262612 — Spraying Ceilings, Walls and Crown Molding diagram (page 11)
Fig. 15 · Spraying Ceilings, Walls and Crown Molding

Setup

Page 12 of the Graco 262612 user manual — Sprayer Setup
Page 12 · click to enlarge
Page 12

Sprayer Setup

Graco 262612 — Sprayer Setup diagram (page 12)
Fig. 16 · Sprayer Setup

This sprayer arrives from the factory with a small amount of test material in the system. It is important that you flush this material from the sprayer before using it for the first time:

5. Engage trigger lock and put prime/pressure relief valve UP to release pressure.
1. Fill material cup with water or compatible solvent, thread onto sprayer and hand tighten.
6. Unscrew and remove material cup.
7. Disengage trigger lock, put prime/pressure relief valve DOWN, hold sprayer slightly above material cup, and pull trigger to discharge fluid from pump.
Graco 262612 — Sprayer Setup diagram (page 12)
Fig. 17 · Sprayer Setup
2. Put prime/pressure relief valve to UP position, then hold trigger in for 10 seconds.
3. Put prime/pressure relief valve DOWN to spray position.
8. Put prime/pressure relief valve UP and pull trigger to finish material flushing.
9. Discard material in cup.
4. Reverse spray tip to UNCLOG position and trigger sprayer into a waste area for 10 seconds.
Graco 262612 — Sprayer Setup diagram (page 12)
Fig. 18 · Sprayer Setup

Setup

Page 13 of the Graco 262612 user manual — Reversible Tip Selection Chart
Page 13 · click to enlarge
Page 13

Starting a New Job (or Refilling the Cup)

Starting a New Job (or Refilling the Cup)

4. Reverse spray tip to UNCLOG position and spray into waste area for five seconds.
Graco 262612 — Starting a New Job (or Refilling the Cup) diagram (page 13)
Fig. 19 · Starting a New Job (or Refilling the Cup)
Graco 262612 — Starting a New Job (or Refilling the Cup) diagram (page 13)
Fig. 20 · Starting a New Job (or Refilling the Cup)
  • Remove entire sprayer from hazardous location when refilling.
5. Put prime/pressure relief valve UP to release pressure. Then rotate tip back to spray position. NOTE: Failure to perform this operation could result in poor spray pattern.
1. Engage trigger lock and put prime/pressure relief valve UP to release pressure.
2. Install material cup liner, fill with material, and thread onto sprayer.

Reversible Tip Selection Chart

Graco 262612 — Reversible Tip Selection Chart diagram (page 13)
Fig. 21 · Reversible Tip Selection Chart
Graco 262612 — Reversible Tip Selection Chart diagram (page 13)
Fig. 22 · Reversible Tip Selection Chart
3. To prime pump, disengage trigger lock and trigger sprayer for 10 seconds. Then release trigger and put prime/relief valve DOWN to spray position.
Graco 262612 — Reversible Tip Selection Chart diagram (page 13)
Fig. 23 · Reversible Tip Selection Chart

Use with all fine finish materials including “hot” solvents.

Page 14 of the Graco 262612 user manual — Aiming Sprayer
Page 14 · click to enlarge
Page 14

Install Tip/Guard Assembly (if not installed)

Install Tip/Guard Assembly (if not installed)

Getting Started with Basic Techniques

Use a piece of scrap cardboard to practice these basic spraying techniques before you begin spraying the surface.

  • Hold sprayer 10 in. (25 cm) from surface and aim straight at surface. Tilting sprayer to direct spray angle causes an uneven finish.
Graco 262612 — Install Tip/Guard Assembly (if not installed) diagram (page 14)
Fig. 24 · Install Tip/Guard Assembly (if not installed)
Graco 262612 — Install Tip/Guard Assembly (if not installed) diagram (page 14)
Fig. 25 · Install Tip/Guard Assembly (if not installed)
1. Engage trigger lock and put prime/pressure relief valve UP to release pressure.
  • Flex wrist to keep sprayer pointed straight. Fanning sprayer to direct spray at angle causes uneven finish.
2. Install filter to Spray Tip/Guard Assembly. NOTE: Filter assembly is reverse-threaded. Turn left (or counter-clockwise) to install. Turn right (or clockwise) to remove.

even finish thin thick thin

Graco 262612 — Install Tip/Guard Assembly (if not installed) diagram (page 14)
Fig. 26 · Install Tip/Guard Assembly (if not installed)

Triggering Sprayer

Pull trigger after starting stroke. Release trigger before end of stroke. Sprayer must be moving when trigger is pulled and released.

3. Screw Tip/Guard Assembly onto sprayer. Tighten retaining nut until completely engaged with sprayer. Do not overtighten nut.
Graco 262612 — Triggering Sprayer diagram (page 14)
Fig. 27 · Triggering Sprayer
Graco 262612 — Triggering Sprayer diagram (page 14)
Fig. 28 · Triggering Sprayer

Start Moving Pull Trigger Release Trigger

Aiming Sprayer

Aim tip of sprayer at bottom edge of previous stroke, over- lapping each stroke by half.

Graco 262612 — Aiming Sprayer diagram (page 14)
Fig. 29 · Aiming Sprayer
Page 15 of the Graco 262612 user manual — Unclogging Spray Tip/Guard Assembly
Page 15 · click to enlarge
Page 15

Unclogging Spray Tip/Guard Assembly

Unclogging Spray Tip/Guard Assembly

5. Disengage trigger lock, put prime/pressure relief valve DOWN to spray position, and resume spraying.

Do not operate or spray near children. Do not aim the sprayer at, or spray any person or animal. Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.

6. If tip is still clogged, you may have to repeat steps 1 - 5 and rotate the tip from SPRAY to UNCLOG several times. Repeat step 1 to release pressure, remove and clean filter, or replace with new tip assembly.
1. To unclog tip obstruction, engage trigger lock and put prime/pressure relief valve UP to release pressure.
2. Reverse spray tip to UNCLOG position.
3. Aim sprayer at waste area, disengage trigger lock, and put prime/pressure relief valve DOWN to spray position. Pull trigger to clear clog.
7. When obstruction is cleared, engage trigger lock and rotate arrow-shaped handle back to SPRAY position.
4. Engage trigger lock. Put prime/pressure relief valve UP to release pressure and rotate spray tip back to SPRAY position.

ti14994a ti14999a ti16699a

Page 16 of the Graco 262612 user manual — Flushing Sprayer
Page 16 · click to enlarge
Page 16

Shutdown and Cleaning

3. Remove and clean sprayer intake tube and screen with water (or flushing fluid) and a brush every time you flush the sprayer. Reconnect intake tube.
Graco 262612 — Shutdown and Cleaning diagram (page 16)
Fig. 30 · Shutdown and Cleaning

Flushing Sprayer

4. Clean cup if not using a liner, and fill with water or appropriate flushing fluid.
Graco 262612 — Flushing Sprayer diagram (page 16)
Fig. 31 · Flushing Sprayer

Do not spray solvents through the spray tip. Clean the tip in a bucket of compatible solvent.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.

Graco 262612 — Flushing Sprayer diagram (page 16)
Fig. 32 · Flushing Sprayer
5. Reconnect material cup and shake sprayer to move clean water around and clean all areas inside of cup.
Graco 262612 — Flushing Sprayer diagram (page 16)
Fig. 33 · Flushing Sprayer
1. Engage trigger lock and pull prime/pressure relief valve UP to release pressure.
2. Remove material cup and return excess material to proper container. If used, properly dispose the cup liner.
6. Disconnect trigger lock and trigger sprayer for approximately 15 seconds. Engage trigger lock.
7. Discard contaminated fluid and refill with appropriate flushing fluid.

Shutdown and Cleaning

Page 17 of the Graco 262612 user manual — Shutdown and Cleaning
Page 17 · click to enlarge
Page 17
8. Disengage trigger lock, reverse tip to UNCLOG position, and pull trigger for 5 seconds to prime sprayer.
11. Engage trigger lock and put prime/pressure relief valve UP to release pressure.
12. Remove material cup and discard used fluid.
9. Put prime/pressure relief valve DOWN to spray position. Trigger sprayer into waste area until no paint appears in water or flushing fluid.
13. Use a stiff wire such as a paper clip to make sure vent hole is open.
10. If sprayer is not completely clean, repeat steps 4-9.
14. Remove Spray Tip/Guard Assembly and clean with water or flushing fluid. A soft brush can be used to loosen and remove dried material if needed. To avoid serious injury or damage to equipment, do not expose the sprayer electronics to flushing solvents. Keep sprayer at least 10 in. above the rim of the container when flushing.

ti15529a ti16727a NOTICE The tip is permanently attached to the guard. Removing the tip from the guard will result in damage to the tip assembly.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area. When flushing with solvents, always ground the sprayer and waste container.

Do not store tip/guard assembly or suction tube in sol- vent other than mineral spirits. Damage to parts may occur.

Shutdown and Cleaning · ti14991

Page 18 of the Graco 262612 user manual — Storage
Page 18 · click to enlarge
Page 18

Cleaning Sprayer Exterior

1. Dilute 4 oz. bottle of Pump Armor Concentrate with an additional 4 oz. of water in material cup.
  • Wipe paint off outside of sprayer using a soft cloth moistened with water or flushing fluid. Do NOT submerge the sprayer.
Graco 262612 — Cleaning Sprayer Exterior diagram (page 18)
Fig. 34 · Cleaning Sprayer Exterior
2. Thread cup into sprayer, put prime/pressure relief valve to UP position and squeeze sprayer trigger for approximately 10 seconds.
Graco 262612 — Cleaning Sprayer Exterior diagram (page 18)
Fig. 35 · Cleaning Sprayer Exterior
3. Reverse spray tip to UNCLOG position, put prime/pressure relief valve DOWN to spray position, and aim sprayer into waste area. Pull trigger for 1-2 seconds.

This sprayer is equipped with a static wick that reduces the build-up of static charge to reduce the risk of fire and explosion. KEEP THIS SURFACE CLEAN OF OVER- SPRAY.

4. Properly dispose of used Pump Armor mixture from material cup and rinse cup with water.

Fine Finish Tip Wear

  • Fine Finish Tip/Guard assembly may require replacement depending on abrasiveness of paint.
  • Do not spray with worn tip. See Troubleshooting , page 26.

Storage

5. Recharge battery to full charge before storage. See Charging the Battery , page 8.
6. Store sprayer indoors in a cool, dry place. Store in an upright position only . Never store sprayer with material in the cup.
Graco 262612 — Storage diagram (page 18)
Fig. 36 · Storage
Graco 262612 — Storage diagram (page 18)
Fig. 37 · Storage

Storage · 4 oz

Page 19 of the Graco 262612 user manual — Replacement Parts and Kits
Page 19 · click to enlarge
Page 19

Replacement Parts and Kits

Replacement Parts and Kits

Graco 262612 — Replacement Parts and Kits diagram (page 19)
Fig. 38 · Replacement Parts and Kits
Page 20 of the Graco 262612 user manual — Number: Description
Page 20 · click to enlarge
Page 20

Replacement Parts and Kits

Parts List

If you have this model sprayer (model number is the same as the part number,

Order Part

Ref.

Number: Description

which is below the handle)

Models 16F887, 16H829 24J421 Bare Sprayer (no tip, battery, suction tube, or material cup) Model 16H240 24J435 Bare Sprayer (no tip, battery, suction tube, or material cup) Models 16H243, 262612 24J555 Bare Sprayer (no tip, battery, suction tube, or material cup) Models 16H241, 16H242 24J581 Bare Sprayer (no tip, battery, suction tube, or material cup) 1 All Models 243103 Pump Armor (32oz) 2 Non-Euro Models 16F887, 16H240, 16H242 16M816 Startup/Storage Kit Euro Models 16H241, 16H829, 16H243, 262612, 16H245 16P358 Startup/Storage Kit

3 All Models 24J422 Storage Case 4 100-120V Models 16F887, 16H240, 16H242 16D559 Lithium Ion Battery Charger 230V Models 16H241, 16H829, 16H243, 262612, 16H245 16G615 Lithium Ion Battery Charger

5 All Models FNS208 208 Fine Finish Spray Tips/Guard Assembly All Models FNS308 308 Fine Finish Spray Tips/Guard Assembly All Models FNS210 210 Fine Finish Spray Tips/Guard Assembly All Models FNS310 310 Fine Finish Spray Tips/Guard Assembly All Models FNS410 410 Fine Finish Spray Tips/Guard Assembly All Models FNS312 312 Fine Finish Spray Tips/Guard Assembly All Models FNS412 412 Fine Finish Spray Tips/Guard Assembly 6 All Models 24E376 Tip Filter Kit, 1-pack, 60 mesh All Models 24F039 Tip Filter Kit, 3-pack, 60 mesh All Models 24F640 Tip Filter Kit, 1-pack, 100 mesh All Models 24F641 Tip Filter Kit, 1-pack, 60 mesh 7 All Models 16H933 Packing, O-Ring (included in 8) 8 All Models 24J433 Kit, repair, needle assembly (includes 7 and wrench) 9 All Models 115478 Screw (included in 30) 10 All Models 16U235 Complete Pump Assembly (includes 11-17, 24-28, 44, 62, 63, 65, 66, 68-70) All Models 16U237 Pump Housing only (includes 26, 27, 44, 62, 63, 65, 66, 68-70) 11 All Models 24J424 Inlet Valve Repair Kit (includes 11, 12, 13) (included in 16) 12 All Models 24J424 Inlet Valve Repair Kit (includes 11, 12, 13) (included in 16) 13 All Models 24J424 Inlet Valve Repair Kit (includes 11, 12, 13) (included in 16) 14 All Models 124582 O-Ring (included in 16) 15 All Models 119790 O-Ring (included in 16) 16 All Models 16H641 Pump Valve Repair Kit (includes 11-17, 24 and wrench) 17 All Models 16H934 O-Ring (included in 16, 21) 20 All Models 16J731 Seal, Reservoir (included in 23, 51) 21 All Models 24J423 Tube, suction with strainer inlet (includes 17) 23 All Models 16H618 Material Cup with cover and seal (includes 51) 24 All Models 16H641 Pump Valve Repair Kit (includes 11-17, 24 and wrench) 25 All Models 16H119 Kit, repair, prime / pressure relief valve (includes 43-45) 26 All Models 16U235 Complete Pump Assembly (includes 11-17, 24-28, 44, 62, 63, 65, 66, 68-70) All Models 16U237 Pump Housing only (includes 26, 27, 44, 62, 63, 65, 66, 68-70) 27 All Models 16U235 Complete Pump Assembly (includes 11-17, 24-28, 44, 62, 63, 65, 66, 68-70) All Models 16U237 Pump Housing only (includes 26, 27, 44, 62, 63, 65, 66, 68-70) 28 All Models 16U236 Kit, reciprocator (includes 38 (qty 10), 44, 62, 63, 65, 66, 68-70) 29 All Models 16G740 Screw (included in 30) 30 All Models 16U239 Kit, repair, drive housing (includes 9, 29, 38 (qty 10), 44, 62, 63, 65-70) 31 All Models 16U234 Kit, repair, motor, control board (includes 29, 34, 38 (qty 10) 44, 62, 63, 65-70) Table continues on the following page.

Page 21 of the Graco 262612 user manual — Number: Description
Page 21 · click to enlarge
Page 21

Replacement Parts and Kits

If you have this model sprayer (model number is the same as the part number,

Order Part

Ref.

Number: Description

which is below the handle)

32 Models 16F887, 16H241, 16H242, 16H829 16U240 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Model 16H240 16U241 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Models 16H243, 16H245, 262612 16U242 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) 33 All Models 16U238 Kit, repair, switch (included in 31) 34 Models 16F887, 16H241, 16H242, 16H829 16U240 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Model 16H240 16U241 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Models 16H243, 16H245, 262612 16U242 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) 35 Models 16F887, 16H241, 16H242, 16H829, 16H240 16E859 Label, Made in USA

Models 16H243, 16H245, 262612 16F636 Label, Made in USA 36 All Models 16C936 Plug, Service Hole 37 Models 16F887, 16H241, 16H242, 16H829 16U240 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Model 16H240 16U241 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Models 16H243, 16H245, 262612 16U242 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) 38 All Models 119236 Screw 39 Models 16F887, 16H241, 16H242, 16H829 16U240 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Model 16H240 16U241 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Models 16H243, 16H245, 262612 16U242 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) 40 Models 16F887, 16H829 16G644 Label, brand Model 16H240 16G645 Label, brand Model 16H241, 16H242 16H831 Label, brand Model 16H243, 262612 16H816 Label, brand 41 All Models 16G643 Label 42 All Models 16H256 Reel, Ground 43 All Models 16H119 Kit, repair, prime / pressure relief valve (includes 43-45) 44 All Models 16H842 Pin 45 All Models 16H119 Kit, repair, prime / pressure relief valve (includes 43-45) 46 All Models 16G610 Battery 51 All Models 24D425 Kit, lid 53 All Models 16D562 Cup Liner Replacement (10 pack) 56 Models 16F887, 16H241, 16H242, 16H829 16U240 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Model 16H240 16U241 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Models 16H243, 16H245, 262612 16U242 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) 57▲ Models 16F887, 16H240 *24J425 Warning Labels Kit ENG/FRE/SPA Models 16H829 *24J518 Warning Labels Kit SPA/POR/ITA Model 16H829 Models 16H241, 16H242 *24J554 Warning Labels Kit ASIA/ANZ Models 16H241, 16H242 * Contains all warning labels for the models listed Models 16H243, 262612 24J521 Multi-Language Warning Labels Kit, Body Models 16H243, 262612 24J519 Multi-Language Warning Labels Kit, Ground Spool Models 16H243, 262612 24J520 Multi-Language Warning Labels Kit, Charger Models 16H243, 262612 24J522 Multi-Language Warning Labels Kit, Battery 59▲ All Models Warning Label (included in 24J425) 60 All Models 16G646 Control Label

Page 22 of the Graco 262612 user manual — Number: Description
Page 22 · click to enlarge
Page 22

Replacement Parts and Kits

If you have this model sprayer (model number is the same as the part number,

Order Part

Ref.

Number: Description

which is below the handle)

61 Model 16H241 only 124783 Plug Adapter 62-70 Models 16F887, 16H241, 16H242, 16H829 16U240 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Model 16H240 16U241 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) Models 16H243, 16H245, 262612 16U242 Enclosure replacement kit (includes 20, 34-37, 38 (qty 10), 39, 44, 56, 62-66, 68-70) 73▲ All Models Warning Label (included in 24J425) 74 All Models 16H137 O-Ring (included in 5)

▲ Replacement Danger and Warning Labels, Tags and Cards are available at no cost.

Page 23 of the Graco 262612 user manual — Alternate Priming Method
Page 23 · click to enlarge
Page 23

Alternate Priming Method

5. Leaving the sprayer upside-down, disengage trigger lock and quickly trigger sprayer until material comes out of drain port.
Graco 262612 — Alternate Priming Method diagram (page 23)
Fig. 39 · Alternate Priming Method

Move sprayer to a non-hazardous area before servicing.

If sprayer fails to prime, the inlet valve may be stuck due to paint residue. Perform the steps below.

Graco 262612 — Alternate Priming Method diagram (page 23)
Fig. 40 · Alternate Priming Method
6. Install strainer on suction tube and thread material cup back onto sprayer.
1. Engage trigger lock and pull prime/pressure relief valve UP to release pressure.
2. Remove material cup and suction tube.
Graco 262612 — Alternate Priming Method diagram (page 23)
Fig. 41 · Alternate Priming Method
7. Trigger gun for 10 seconds then release trigger and put prime/pressure relief valve DOWN to spray position.
Graco 262612 — Alternate Priming Method diagram (page 23)
Fig. 42 · Alternate Priming Method
8. Reverse spray tip to UNCLOG position and spray into waste area for five seconds to ensure sprayer has primed.
3. Use a pencil or thin rod to lightly push on inlet valve to make sure it moves up and down freely.
9. Pull prime/pressure relief valve up to release pressure, reverse spray tip to SPRAY position and put prime/pressure relief valve DOWN to spray position. Sprayer is now ready to spray. Perform Starting New Job procedure, page 13.
4. If inlet valve does not move freely, perform Inlet Valve Removal , page 24. If inlet valve moves freely, install suction tube without strainer, turn sprayer upside-down, and slowly pour flushing material into suction tube until full.

Alternate Priming Method

Page 24 of the Graco 262612 user manual — Installation
Page 24 · click to enlarge
Page 24

Inlet Valve Removal/Service

Installation

Graco 262612 — Installation diagram (page 24)
Fig. 43 · Installation
1. Place inlet valve (b) with spring (a) on top of inlet fitting (d). Push inlet fitting up into pump cavity.
Graco 262612 — Installation diagram (page 24)
Fig. 44 · Installation
1. Engage trigger lock and pull prime/pressure relief valve UP to release pressure.
2. Hold inlet in place and turn sprayer upside-down. Remove inlet fitting and visually check to see that inlet valve has seated correctly.
3. Hold sprayer upside-down and use wrench or socket to loosen and remove inlet fitting, inlet valve, and spring.
3. Replace inlet fitting and use wrench or socket to tighten to 10 ft-lb.
4. Use a pencil or thin rod to lightly push on inlet valve to make sure it moves up and down freely. Perform Starting New Job procedure, page 13.
Graco 262612 — Installation diagram (page 24)
Fig. 45 · Installation
4. Clean as much excess material from inlet cavity as possible. Make sure you also clean spring (a), inlet valve (b), o-ring (c), and top of inlet fitting (d).
Graco 262612 — Installation diagram (page 24)
Fig. 46 · Installation
5. Use a thin wire to check that the outlet valve moves freely. If valve does not move freely, perform Outlet Valve Repair , page 25.

Inlet Valve Removal/Service

Page 25 of the Graco 262612 user manual — Removal
Page 25 · click to enlarge
Page 25

Outlet Valve Repair

4. Use tool (supplied) to loosen and remove outlet valve fitting. Make sure old o-ring, seat, outlet valve, and spring are out of pump outlet cavity.
Graco 262612 — Outlet Valve Repair diagram (page 25)
Fig. 47 · Outlet Valve Repair

Move sprayer to a non-hazardous area before servicing.

Removal

Graco 262612 — Removal diagram (page 25)
Fig. 48 · Removal
1. Engage trigger lock and pull prime/pressure relief valve UP to release pressure.
1. Screw outlet valve fitting into threads. Use tool (supplied) and tighten to 8 ft-lb.
Graco 262612 — Removal diagram (page 25)
Fig. 49 · Removal
3. Remove pump outlet cap.
Graco 262612 — Removal diagram (page 25)
Fig. 50 · Removal

Outlet cap prevents the discharge of static electricity. Always replace outlet cap after installing outlet valve.

Outlet Valve Repair

Page 26 of the Graco 262612 user manual — Problem Cause Solution
Page 26 · click to enlarge
Page 26

Troubleshooting

Check everything in this Troubleshooting Table before you bring the sprayer to an authorized service center.

Problem Cause Solution

Sprayer makes no sound when trigger is pulled

Trigger is locked. Disengage trigger lock. See page 9.

Status Indicator Light is solid RED when triggering, indicating that the battery charge is low, or the battery is too cold.

Replace with charged battery and place old battery in charger, or allow battery to warm up.

Status Indicator Light is flashing RED when triggering, indicating that the bat- tery is too hot to operate.

Allow battery to cool.

Status Indicator Light does not light when sprayer is triggered. Battery is not installed or is damaged.

Install battery or replace.

Sprayer makes sound but no material is sprayed when trigger is pulled

Sprayer is not primed. Prime the pump. See Starting a new Job (or Refilling the Cup), page 13. If sprayer fails to prime, follow Alternate Priming Method (page 23).

Prime/relief valve is in UP position. Put valve DOWN to spray position.

Suction Tube is missing or improperly installed.

Make sure Suction Tube is properly installed.

Suction Tube screen or vent hole is clogged.

See Shutdown and Cleaning, page 16.

Suction Tube o-rings are damaged or missing.

Replace Suction Tube o-rings.

Pressure control is too low or Hi/Lo switch is in Lo range.

Turn pressure control up or shift Hi/Lo switch to Hi range.

Sprayer has been tilted too far and suc- tion tube has lost contact with material.

Make sure cup is filled with material. Rotate suction tube, page 11. Do not tilt the cup too far. Prime the pump. See Starting a new Job (or Refilling the Cup), page 13.

No or low material in cup. Refill cup with material and prime the pump.

Inlet valve is stuck from material residue left in sprayer.

Use a pencil or thin rod to lightly push on inlet valve to make sure it moves up and down freely. See Inlet Valve Removal/Service, page 24.

Pump is clogged, frozen, or has debris inside.

See Outlet Valve Repair, page 25 and Inlet Valve Removal/Service, page 24.

Material is leaking from hole in front of sprayer.

Sprayer has reached maximum life. Replace sprayer.

Troubleshooting

Page 27 of the Graco 262612 user manual — Spray Pattern Diagnostics
Page 27 · click to enlarge
Page 27

Problem Cause Solution

Sprayer sprays with poor results Tip is partially clogged See Unclogging Tip/Guard Assembly, page 15.

Incorrect tip for application of material.

See Reversible Tip Selection Chart, page 13.

Suction Tube screen is partially clogged. Clean or replace Suction Tube. See page 16.

Material being sprayed is aerated because it was shaken.

Do NOT shake material. Stir the material or check the manufacturer’s recommen- dation for the material being sprayed.

Pressure control is too low or Hi/Lo switch is in Lo range

Turn up pressure control or shift Hi/Lo switch to hi range.

Material being sprayed is too cold to spray.

Warm material.

Inlet or outlet valves are worn. See Outlet Valve Repair, page 25 and Inlet Valve Removal/Service, page 24.

Paint leaks from sprayer trigger area. Sprayer has reached its maximum life. Replace sprayer.

Battery is discharged but charger still dis- plays green light when battery is inserted.

Damaged battery. Replace battery.

Battery does not last long. Battery life varies with material, tip size, pressure, and speed setting.

See Charging the Battery, page 8.

Spray Pattern Diagnostics

Problem Cause Solution

Spray pattern is pulsating: Operator is moving too fast while spraying. Slow speed of movement.

Hi/Lo switch is in Lo range. Shift Hi/Lo switch to Hi range.

Incorrect tip for application of material.

See Reversible Tip Selection Chart, page 13.

Material not compatible with sprayer. Switch material.

Inlet or outlet valves are worn. See Outlet Valve Repair, page 25 and Inlet Valve Removal/Service, page 24. ti15526a

Troubleshooting

Page 28 of the Graco 262612 user manual — Problem Cause Solution
Page 28 · click to enlarge
Page 28

Problem Cause Solution

Spray pattern has dripping: Sprayer is moving too slow for material. Move sprayer faster while spraying.

Sprayer is too close to target surface. Move sprayer away from surface 10 in. (25 cm)

Holding trigger while changing spray direction.

Release trigger when changing directions.

Incorrect tip for application of material.

See Reversible Tip Selection Chart, page 13.

Pressure control is too high or Hi/Lo Switch is in Hi range.

Turn down pressure control or shift Hi/Lo Switch to Lo range.

Incorrect tip for application of material. See Reversible Tip Selection Chart, page 13.

Incorrect tip for application of material. See Reversible Tip Selection Chart, page 13.

Spray pattern “spits” at the end or beginning:

Excess material has accumulated on Spray Tip/Guard Assembly.

See Shutdown and Cleaning, page 16.

See Install Tip/Guard Assembly, page 14.

Seat is worn. Replace Spray tip. Tip continues to drip or ooze material after trigger is released:

Sprayer is worn out. Replace sprayer.

See Install Tip/Guard Assembly, page 14.

Seat is worn. Replace Spray tip.

Needle valve is damaged or worn out. Replace needle valve.

Troubleshooting

Page 29 of the Graco 262612 user manual — Battery:
Page 29 · click to enlarge
Page 29

Technical Data

Sprayer:

Adjustable Pressure Range 500 to 1500 psi (34 to 103 bar, 0.34 to 10.3 MPa)

Maximum working pressure 1700 psi (117 bar, 11.7 MPa)

Weight 5.0 lb (2.25 kg)

Dimensions:

Length 13.75 in. (34.9 cm)

Width 5.5 in. (14.0 cm)

Height 9.7 in. (24.6 cm)

Storage temperature range ◆❖ 32° to 113°F (0° to 45°C)

Operating temperature range ✔ 40° to 90° F (4° to 32°C)

Storage Humidity Range 0% to 95% relative humidity, non-condensing

Sound Pressure Level 79.5 dBa† (for sound power level, add 11 dBa)

Vibration Level Acceleration Less than 8.2 feet/s2 2.5 m/s2††

Charger:

Charging Time 25 minutes to 80%, 40 minutes to 100%

Power Source 120 VAC

Battery:

Voltage 18 VDC, Lithium Ion

Capacity 1.2 Ah, 21.6 Wh

◆Pump damage will occur if fluid freezes in pump. ❖Damage to plastic parts may result if impact occurs in low temperature conditions. ✔Changes in paint viscosity at very low or very high temperatures can affect sprayer performance. † per ISO 3744 measured at 3.1 feet (1m) †† per ISO 5349, no load condition

Technical Data

Page 30 of the Graco 262612 user manual — EXAMPLE
Page 30 · click to enlarge
Page 30

Preferred Material Settings Log

Preferred Material Settings Log

Graco 262612 — Preferred Material Settings Log diagram (page 30)
Fig. 51 · Preferred Material Settings Log

EXAMPLE

Page 31 of the Graco 262612 user manual — Notes
Page 31 · click to enlarge
Page 31

Notes

Page 32 of the Graco 262612 user manual — Graco Information
Page 32 · click to enlarge
Page 32

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6926 or Toll Free: 1-800-690-2894 Fax: 612-623-6893 Toll Free Fax: 1-800-334-6955

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents Original instructions. This manual contains English. MM 3A1698

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea
  • GRACO INC. AND SUBSIDIARIES
  • P.O. BOX 1441
  • MINNEAPOLIS MN 55440-1441
  • USA

Copyright 2010, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com Revised January 2013

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Sprayer makes no sound when trigger is pulledTrigger is locked.Disengage trigger lock. See page 9. p.26
Sprayer makes no sound when trigger is pulledStatus Indicator Light is solid RED when triggering, indicating that the battery charge is low, or the battery is too cold.Replace with charged battery and place old battery in charger, or allow battery to warm up. p.26
Sprayer makes no sound when trigger is pulledStatus Indicator Light is flashing RED when triggering, indicating that the bat- tery is too hot to operate.Allow battery to cool. p.26
Sprayer makes no sound when trigger is pulledStatus Indicator Light does not light when sprayer is triggered. Battery is not installed or is damaged.Install battery or replace. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledSprayer is not primed.Prime the pump. See Starting a new Job (or Refilling the Cup), page 13. If sprayer fails to prime, follow Alternate Priming Method (page 23). p.26
Sprayer makes sound but no material is sprayed when trigger is pulledPrime/relief valve is in UP position.Put valve DOWN to spray position. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledSuction Tube is missing or improperly installed.Make sure Suction Tube is properly installed. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledSuction Tube screen or vent hole is clogged.See Shutdown and Cleaning, page 16. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledSuction Tube o-rings are damaged or missing.Replace Suction Tube o-rings. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledTip is not in SPRAY position.Turn tip to SPRAY position. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledTip is clogged.See Unclogging Tip/Guard Assembly, page 15. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledTip filter is clogged.Remove and clean tip filter. See Unclog- ging Tip/Guard Assembly, page 15. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledPressure control is too low or Hi/Lo switch is in Lo range.Turn pressure control up or shift Hi/Lo switch to Hi range. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledSprayer has been tilted too far and suc- tion tube has lost contact with material.Make sure cup is filled with material. Rotate suction tube, page 11. Do not tilt the cup too far. Prime the pump. See Starting a new Job (or Refilling the Cup), page 13. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledNo or low material in cup.Refill cup with material and prime the pump. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledInlet valve is stuck from material residue left in sprayer.Use a pencil or thin rod to lightly push on inlet valve to make sure it moves up and down freely. See Inlet Valve Removal/Service, page 24. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledPump is clogged, frozen, or has debris inside.See Outlet Valve Repair, page 25 and Inlet Valve Removal/Service, page 24. p.26
Sprayer makes sound but no material is sprayed when trigger is pulledMaterial is leaking from hole in front of sprayer.Sprayer has reached maximum life. Replace sprayer. p.26
Sprayer sprays with poor resultsTip is partially cloggedSee Unclogging Tip/Guard Assembly, page 15. p.27
Sprayer sprays with poor resultsTip is not in correct positionRotate tip to SPRAY position. p.27
Sprayer sprays with poor resultsIncorrect tip for application of material.See Reversible Tip Selection Chart, page 13. p.27
Sprayer sprays with poor resultsTip filter is partially clogged or damaged.Clean or replace filter. See page 15. p.27
Sprayer sprays with poor resultsSuction Tube screen is partially clogged.Clean or replace Suction Tube. See page 16. p.27
Sprayer sprays with poor resultsTip is worn or damagedReplace tip. See Install Tip/Guard Assembly, page 14. p.27
Sprayer sprays with poor resultsMaterial being sprayed is aerated because it was shaken.Do NOT shake material. Stir the material or check the manufacturer’s recommen- dation for the material being sprayed. p.27
Sprayer sprays with poor resultsPressure control is too low or Hi/Lo switch is in Lo rangeTurn up pressure control or shift Hi/Lo switch to hi range. p.27
Sprayer sprays with poor resultsMaterial being sprayed is too cold to spray.Warm material. p.27
Sprayer sprays with poor resultsInlet or outlet valves are worn.See Outlet Valve Repair, page 25 and Inlet Valve Removal/Service, page 24. p.27
Paint leaks from sprayer trigger area.Sprayer has reached its maximum life.Replace sprayer. p.27
Battery is discharged but charger still dis- plays green light when battery is inserted.Damaged battery.Replace battery. p.27
Battery does not last long.Battery life varies with material, tip size, pressure, and speed setting.See Charging the Battery, page 8. p.27
Spray pattern is pulsating:Operator is moving too fast while spraying.Slow speed of movement. p.27
Spray pattern is pulsating: p.27
Spray pattern is pulsating:Hi/Lo switch is in Lo range.Shift Hi/Lo switch to Hi range. p.27
Spray pattern is pulsating:Tip or tip filter is clogged.Unclog tip or clean tip filter, page 15. p.27
Spray pattern has tails:Pressure control is too low.Turn up pressure control. p.27
Spray pattern has tails:Incorrect tip for application of material.See Reversible Tip Selection Chart, page 13. p.27
Spray pattern has tails: p.27
Spray pattern has tails:Material not compatible with sprayer.Switch material. p.27
Spray pattern has tails:Inlet or outlet valves are worn.See Outlet Valve Repair, page 25 and Inlet Valve Removal/Service, page 24. p.27
ti15526a p.27
Spray pattern has dripping:Sprayer is moving too slow for material. Sprayer is too close to target surface. Holding trigger while changing spray direction. Incorrect tip for application of material. Pressure control is too high or Hi/Lo Switch is in Hi range. Tip is worn or damaged.Move sprayer faster while spraying. p.28
Spray pattern has dripping:Move sprayer away from surface 10 in. (25 cm) p.28
Spray pattern has dripping: p.28
Spray pattern has dripping:Release trigger when changing directions. p.28
Spray pattern has dripping:See Reversible Tip Selection Chart, page 13. p.28
Spray pattern has dripping:Turn down pressure control or shift Hi/Lo Switch to Lo range. p.28
Spray pattern has dripping:Replace tip. See Install Tip/Guard Assembly, page 14. p.28
Spray pattern is too narrow:Sprayer is too close to target surface.Move sprayer away from surface 10 in. (25 cm) p.28
Spray pattern is too narrow:Incorrect tip for application of material. Tip is worn or damaged.See Reversible Tip Selection Chart, page 13. p.28
ti15523a ti15523a p.28
ti15523a ti15523aReplace tip. See Install Tip/Guard Assembly, page 14. p.28
Spray pattern is too wide:Sprayer is too far away from target surface. Incorrect tip for application of material.Move sprayer closer to surface. p.28
Spray pattern is too wide:See Reversible Tip Selection Chart, page 13. p.28
Spray pattern is too wide: p.28
tti1i155552277aa p.28
Spray pattern “spits” at the end or beginning:Excess material has accumulated on Spray Tip/Guard Assembly. Tip filter is partially clogged or damaged. Tip/Guard Assembly not threaded com- pletely onto sprayer. Seat is worn.See Shutdown and Cleaning, page 16. p.28
Spray pattern “spits” at the end or beginning: p.28
Spray pattern “spits” at the end or beginning:Clean or replace filter. See page 15. p.28
ttii1155552255aa p.28
ttii1155552255aaSee Install Tip/Guard Assembly, page 14. p.28
ttii1155552255aaReplace Spray tip. p.28
Tip continues to drip or ooze material after trigger is released: ti15ti512585a28aSprayer is worn out. Tip filter is partially clogged or damaged. Tip/Guard Assembly not threaded com- pletely onto sprayer. Seat is worn.Replace sprayer. p.28
Tip continues to drip or ooze material after trigger is released: ti15ti512585a28aClean or replace filter. See page 15. p.28
Tip continues to drip or ooze material after trigger is released: ti15ti512585a28aSee Install Tip/Guard Assembly, page 14. p.28
Tip continues to drip or ooze material after trigger is released: ti15ti512585a28aReplace Spray tip. p.28
Tip continues to drip or ooze material after trigger is released: ti15ti512585a28aNeedle valve is damaged or worn out.Replace needle valve. p.28

Ask about the Graco 262612

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 262612

Be the first to ask — other owners or our team will answer.

Original document

Graco 262612 manual PDF

32 pages·6.8 MB·Paint Sprayer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…