EN
Graco logo
Official user manual

Graco 253697

22 pages·553 KB·Water Pump·PDF·ENDEFRITNLJA
Graco 253697
Table of Contents 46 sections Instructions · 28:1/33:1 RATIO, WALL MOUNT Bulldog Pumps · 307932R · Table of Contents · … ShowHide
Page 1 of the Graco 253697 user manual — Instructions
Page 1 · click to enlarge
Page 1

Instructions

28:1/33:1 RATIO, WALL MOUNT Bulldog Pumps

307932R

Graco 253697 — Instructions diagram (page 1)
Fig. 1 · Instructions

For ambient temperature spray applications.

Part No. 245187, 33:1, Series B 3300 psi (22.8 MPa, 228 bar) Maximum Fluid Working Pressure 100 psi (700 kPa, 7 bar) Maximum Air Input Pressure

Part No. 253697, 28:1, Series A 2800 psi (19.3 MPa, 193 bar) Maximum Fluid Working Pressure 100 psi (700 kPa, 7 bar) Maximum Air Input Pressure

Part No. 245185, Series B (240 Volt Heater) Part No. 245186, Series B (480 Volt Heater) For heated spray applications.

3000 psi (20.7 MPa, 207 bar) Maximum Fluid Working Pressure 90 psi (600 kPa, 6 bar) Maximum Air Input Pressure

See page 2 for Table of Contents.

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 1998, Graco Inc. is registered to I.S. EN ISO 9001

Parts · Model 245187 Shown

Page 3 of the Graco 253697 user manual — MOVING PARTS HAZARD
Page 3 · click to enlarge
Page 3

SKIN INJECTION HAZARD

Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.

Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgi- cal treatment.

Do not point the gun at anyone or at any part of the body.

Do not put your hand or fingers over the spray tip.

Do not stop or deflect leaks with your hand, body, glove or rag.

Do not “blow back” fluid; this is not an air spray system.

Always have the tip guard and the trigger guard on the gun when spraying.

Check the gun diffuser operation weekly. Refer to the gun manual.

Be sure the gun trigger safety operates before spraying.

Lock the gun trigger safety when you stop spraying.

Follow the Pressure Relief Procedure on page 14 if the spray tip clogs and before cleaning, checking or servicing the equipment.

Tighten all fluid connections before operating the equipment.

Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose.

Use only Graco approved hoses. Do not remove the spring guard that is used to help protect the hose from rupture caused by kinks or bends near the couplings.

MOVING PARTS HAZARD

Moving parts, such as the air motor piston, can pinch or amputate your fingers.

Keep clear of all moving parts when starting or operating the pump.

Before servicing the equipment, follow the Pressure Relief Procedure on page 14 to prevent the equipment from starting unexpectedly.

3 307932

Page 4 of the Graco 253697 user manual — TOXIC FLUID HAZARD
Page 4 · click to enlarge
Page 4

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

Ground the equipment and the object being sprayed. Refer to Grounding on page 5.

If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately. Do not use the equipment until you identify and correct the problem.

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed.

Keep the spray area free of debris, including solvent, rags, and gasoline.

Electrically disconnect all equipment in the spray area.

Extinguish all open flames or pilot lights in the spray area.

Do not smoke in the spray area.

Do not turn on or off any light switch in the spray area while operating or if fumes are present.

Do not operate a gasoline engine in the spray area.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

4 307932

Page 5 of the Graco 253697 user manual — Grounding
Page 5 · click to enlarge
Page 5

General Information

W

Z

2. Air and fluid hoses: use only electrically conductive hoses.
3. Heaters, if used: refer to Viscon HP Heater manual, 309524.
4. Air compressor: follow manufacturer’s recommendations.

Grounding

5. Spray gun: ground through connection to a properly grounded fluid hose and pump.
6. Fluid supply container: follow your local code.

FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE OR EXPLOSION HAZ- ARD on page 4.

7. Object being sprayed: follow your local code.
8. Solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity.
1. Pump: use a ground wire and clamp (supplied). See Fig. 1. Loosen the grounding lug locknut (W) and washer (X). Insert one end of a 1.5 mm (12 ga) minimum ground wire (45) into the slot in lug (Z) and tighten the locknut securely. Connect the other end of the wire to a true earth ground.
9. To maintain grounding continuity when flushing or relieving pressure , hold a metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

5 307932

Page 6 of the Graco 253697 user manual — Supplied Components
Page 6 · click to enlarge
Page 6

Supplied Components

System Accessories

Refer to Fig. 2 for a typical installation of an airless system.

Air and Fluid Hoses

Be sure all air hoses (A) and fluid hoses (G) are prop- erly sized and pressure-rated for your system. Use only electrically conductive hoses.

A red-handled bleed-type master air valve (14) and a fluid drain valve (7) are supplied in your system. These accessories help reduce the risk of serious injury, including fluid injection and splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjusting or repairing the pump.

1. Connect one end of the fluid line (G) to the filter outlet swivel. Connect a fluid hose to each gun (H). Install a fluid shutoff valve (J) at each gun drop. Do not install the spray tip in the gun yet.

The red-handled bleed-type master air valve re- lieves air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpectedly. Locate the valve close to the pump.

2. Close the red-handled bleed valve (14) and air regulator (8). Connect the air hose (A) to the swivel inlet of the air manifold (15).

The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient.

The red-handled bleed-type master air valve (14) is required in your system to relieve air trapped between it and the air motor when the valve is closed (see the WARNING above). Be sure the bleed valve is easily accessible from the pump, and is located downstream from the air regulator.

1. Install an air line filter (B) in the main air line, to remove harmful dirt and moisture from the compressed air supply.

The air regulator (8) controls pump speed and outlet pressure by adjusting the air pressure to the pump. Locate the regulator close to the pump, but upstream from the red-handled bleed-type master air valve (14).

2. Install a second bleed valve (C) in the main air line, to isolate the accessories for servicing.
3. Install a drain valve (D) at the bottom of each air line drop, to drain off moisture.

The air manifold (15) has a swivel air inlet. It mounts to the cart, and provides ports for connect- ing lines to air-powered accessories.

The fluid filter (4) includes a 60 mesh (250 mi- cron) stainless steel element to filter particles from the fluid as it leaves the pump.

4. To provide automatic lubrication of the air motor, install an air line lubricator (E) downstream from the red-handled bleed-type master air valve (14).

The fluid drain valve (7) is required in your sys- tem to relieve fluid pressure in the hose and gun (see the WARNING above).

5. Install a pump runaway valve (F). The runaway valve will automatically shut off the air to the pump if the pump starts running too fast. A pump that runs too fast can be seriously damaged.

The suction hose (24) and tube (25) allow the pump to draw fluid from a 200 liter (55 gallon) drum.

Air Line Accessories · 6 307932

Page 7 of the Graco 253697 user manual — E
Page 7 · click to enlarge
Page 7

KEY

SUPPLIED COMPONENTS

ACCESSORIES YOU MUST SUPPLY

1 Pump 2 Pump Wall Bracket 4 Fluid Filter 7 Fluid Drain Valve (required) 8 Pump Air Regulator 14 Red Handled Bleed-Type Master Air Valve (required, for pump) 15 Air Manifold 24 Suction Hose 25 Suction Tube 45 Ground Wire (required; see page 5 for installation instructions)

A Electrically Conductive Air Hose B Air Line Filter C Bleed-Type Master Air Valve (for accessories) D Air Line Drain Valve E Air Line Lubricator F Pump Runaway Valve G Electrically Conductive Fluid Line H Airless Spray Gun J Fluid Shutoff Valve

E

G

A

J J H

H

F

D

G G

01763A

Model 245187 Shown · 7 307932

Page 8 of the Graco 253697 user manual — Models 245187 and 253697 (for Ambient Temperature Spray Applications)
Page 8 · click to enlarge
Page 8

Models 245187 and 253697 (for Ambient Temperature Spray Applications)

1. Mount the pump wall bracket (2) 5 ft (1.5 m) above the floor. Be sure the wall is strong enough to support the weight of the pump and accessories, fluid, hoses, and stress caused during pump operation. Refer to Mounting Hole Layout on page 20.
2. Connect the air and fluid hoses and the spray gun as explained on page 6.

Model 245187 Shown · 8 307932

Page 9 of the Graco 253697 user manual — Models 245185 and 245186 (for Heated Temperature Spray Applications)
Page 9 · click to enlarge
Page 9

Models 245185 and 245186 (for Heated Temperature Spray Applications)

4. Use M8 or 5/16 in. bolts of the appropriate length and lockwashers (not supplied) to fasten the heater brackets to the wall.
1. Be sure the wall is strong enough to support the weight of the pump and accessories, heaters, hoses, fluid, and stress caused during operation.
5. Bring the hose (31a) from the inlet elbow (32a) of the lower heater (44a) and connect it securely to the swivel (50) coming from the pump outlet. See Fig. 4.
2. Mount the pump wall bracket (2) 5 ft (1.5 m) above the floor. Refer to the Mounting Hole Layout on page 20.
6. Route the hose (31b) from the inlet elbow (32b) of the upper heater (44b), behind the lower heater (44a), and connect it securely to the swivel (34a) at the outlet of the lower heater.
3. Locate the holes for the heater wall brackets (26*) exactly as indicated on page 20. Use the heater wall brackets as templates to mark the wall.
7. Bring the fluid supply hose (31) from the swivel (34b) at the fluid filter (4) outlet and connect it to the main fluid supply line to the guns.
8. Bring the fluid return hose (37) from the three-way ball valve (40) and connect it to the main fluid return line.
9. Connect the air and fluid hoses and the spray gun as explained on page 6.

Connect supply hose (31) to the main fluid supply line to the guns.

Connect return hose (37) to the main fluid return line.

04419D Fig. 4

Show 5 more labels / short text on this page
34a · 32a · 44a · 31a · 9 307932
Page 10 of the Graco 253697 user manual — Accessories for a Heated System
Page 10 · click to enlarge
Page 10

Converting to a Heated System

Installing Dual Heater Mounting Kit 222311

To convert Model 245187 or 253697 to a heated circulating system, order the following parts. The heaters are available in three voltages. Specify which voltage you desire.

Before installing the heaters, dual heater mounting kit and circulating kit, follow the Pressure Relief Procedure on page 14. Disconnect all hoses from the pump.

Two Viscon HP Fluid Heaters – Model 245848 (120 V, single-phase, 19.2 amp) – Model 245863 (240 V, single-phase, 16.7 amp) – Model 245864 (480 V, single-phase, 8.30 amp)

Dual Heater Mounting Kit 222311

Circulating Kit 222312

Warning Label 290074

Apply pipe sealant (36*) to all male threads except at swivel connections.

The Viscon HP Heaters must be installed by a qualified electrician in compliance with all state and local codes and regulations, to reduce the risk of electric shock or other serious injury during installa- tion or operation.

1. Be sure the wall is strong enough to support the weight of the heaters, hoses, fluid, and stress caused during operation. Locate the holes for the heater wall brackets (26*) exactly as indicated on page 20. Note that one heater will be mounted above and slightly to the left of the other. Use the heater wall brackets as templates to mark the wall.

The power supply must match the heaters’ require- ments (see above). Refer to the Viscon HP Heater Manual, 309524, for further information.

Accessories for a Heated System

2. Attach a heater wall bracket to each heater’s mounting posts with the M8 x 1.25 screws and lockwashers supplied with the heater (44).

Viscon HP Heater Cord 110160

12 gauge, rated at 105 C.

3. Use M8 or 5/16 in. bolts of the appropriate length and lockwashers (not supplied) to fasten the heater brackets to the wall.

Do not use in hazardous areas containing flam- mable materials or fumes.

Airless Insulated Hose Kit 222263

25 ft. (7.6 m) nylon fluid hose for use with airless heated systems. Includes an in-line fluid filter, circulat- ing manifold, and 3 ft. (0.9 m) whip hose.

4. Remove the fluid filter (4) and attaching hardware (3, 9) from the pump fluid outlet. Keep the filter, but discard the attaching hardware. See Fig. 5.

10 307932

Page 11 of the Graco 253697 user manual — Converting to a Heated System
Page 11 · click to enlarge
Page 11
5. Screw the 3/4 npt street elbow (28*) into the pump’s fluid outlet. Assemble the nipple (27*), check valve (29*), coupling (30*), and swivel (50*) as shown in Fig. 6. The arrow on the check valve must point down, toward the coupling.
9. Screw the bushing (62) and a 3/8 npt nipple (33*) into the upper heater’s outlet. Screw the fluid filter (4) inlet onto this nipple. Unscrew the adapter (10) from the filter outlet. Screw the 1/4 x 3/8 npt nipple (35*) into the filter outlet, and screw the union (34*) onto the nipple. See Fig. 6.
6. Screw an elbow (32*) onto the lower heater’s inlet. Screw the coupler (63) onto the elbow. Attach the heater hose (31*) to the coupler. Connect the other end of the hose to the swivel (50*) coming from the pump outlet.
7. Screw an elbow (32*) onto the upper heater’s inlet. Screw the coupler (63) onto the elbow. Attach the second heater hose (31*) to the coupler. Run this hose to the left of and behind the lower heater. See Fig. 4.

COMPONENT RUPTURE HAZARD To reduce the risk of overpressurizing your system, which could cause compo- nent rupture and serious injury, never exceed 90 psi (6 bar, 600 kPa) incoming air pres- sure to the pump.

8. Install the bushing (62) and a 3/8 npt nipple (33*) in the lower heater’s outlet. Screw the rigid end of the union (34*) onto this nipple, and screw the swivel end of the union onto the free end of the second heater hose (31*).
10. Install the warning label (51) as shown in Fig. 6.

11 307932

Page 12 of the Graco 253697 user manual — Installing Circulating Kit 222312
Page 12 · click to enlarge
Page 12

Installing Circulating Kit 222312

4. Install the CIRC end of the three-way ball valve (40 ) in the bushing (49 ). Screw a bushing (39 ) onto the IN branch of the three-way valve. Connect the rigid end of the 45 union (38 ) to this bushing. Screw the swivel end of the union (38 ) onto the braided hose (37 ). Connect this hose to the main fluid return line. See Fig. 6.

Before installing the heaters, dual heater mounting kit and circulating kit, follow the Pressure Relief Procedure on page 14. Disconnect all hoses from the pump.

5. Screw another bushing (39 ) onto the DRAIN end of the three-way valve (40 ). Connect the nylon fluid hose (41 ) to this bushing, and connect the return tube (42 ) to the other end of the hose. Place the return tube in the fluid supply container.

Apply pipe sealant (36) to all male threads except at swivel connections.

1. Remove the suction tube (25), fittings (52 and 53), hose (24), and adapter (12). See Fig. 5. Keep these parts for use later.

COMPONENT RUPTURE HAZARD To reduce the risk of overpressurizing your system, which could cause compo- nent rupture and serious injury, never exceed 90 psi (6 bar, 600 kPa) incoming air pres- sure to the pump.

2. Screw nipple (54) and then the tee (48 ) into the elbow (11) at the pump fluid inlet. Screw the 1 x 3/4 npt bushing (55) and then the 3/4 npt x 1/4 npt bushing (49 ) into the branch of the tee. See Fig. 6.
6. Install the warning label (51) as shown in Fig. 6.
3. Reconnect the bushing (12), hose (24), fittings (52 and 53), and suction tube (25).
7. Connect the air and fluid hoses and the spray gun as explained on page 6.

12 307932

Page 13 of the Graco 253697 user manual — Installing Circulating Kit 222312
Page 13 · click to enlarge
Page 13
Graco 253697 — Installing Circulating Kit 222312 diagram (page 13)
Fig. 2 · Installing Circulating Kit 222312

Connect to the main fluid supply line to the guns.

35* · 13 307932

Page 14 of the Graco 253697 user manual — U
Page 14 · click to enlarge
Page 14

Operation/Maintenance

Pressure Relief Procedure

Packing Nut/Wet-Cup

Before starting, fill the packing nut (U) 1/3 full with Graco Throat Seal Liquid (TSL) or compatible solvent. See Fig. 7.

SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.

The packing nut is torqued at the factory and is ready for operation. If it becomes loose and there is leaking from the throat packings, relieve pressure, then tighten the nut as specified in your separate pump manual. Do this whenever necessary. Do not overtighten the packing nut.

are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray tips.

1. Lock the gun trigger safety.

Flush the Pump Before First Use

2. Shut off the air supply to the pump.
3. Close the bleed-type master air valve (required in your system).

Pumps are tested with lightweight oil which is left in to protect the pump parts. To prevent contamination of the fluid, flush the pump with a compatible solvent before using it.

4. Unlock the gun trigger safety.
5. Hold a metal part of the gun firmly to the side of a grounded metal pail, and trigger the gun to relieve pressure.
6. Lock the gun trigger safety.
7. Open the drain valve (required in your system), having a container ready to catch the drainage.
8. Leave the drain valve open until you are ready to spray again.

If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip or hose.

U

Model 254187 Shown · 14 307932

Page 15 of the Graco 253697 user manual — Heated Circulating Systems
Page 15 · click to enlarge
Page 15

Operation/Maintenance

Starting and Adjusting the Pump

9. Use the air regulator to control the pump speed and fluid pressure. Always use the lowest pressure necessary to achieve the desired results. Higher pressures waste fluid and cause premature wear of the pump packings and spray tip.
1. Be sure the air regulator and bleed-type master air valve are closed.
2. Open the bleed-type master air valve.

CAUTION

3. Hold a metal part of the spray gun firmly to the side of a grounded metal pail and trigger the gun.

Do not allow the pump to run dry. It will quickly accelerate to a high speed, causing damage. If your pump is running too fast, stop it immediately and check the fluid supply. If the container is empty and air has been pumped into the lines, refill the con- tainer and prime the pump and the lines, or flush and leave it filled with a compatible solvent. Eliminate all air from the fluid system.

4. Slowly open the air regulator until the pump starts.
5. Allow the pump to cycle slowly until all the air is pushed out of the fluid lines.
6. Release the gun trigger and lock the trigger safety; the pump will stall against the pressure.

Heated Circulating Systems

7. With the pump and lines primed, and with adequate air pressure and volume supplied, the pump will start and stop as the spray gun is triggered and released.

Operating instructions for a heated circulating system are provided in the Viscon HP Heater manual, 309524. Read and understand all warnings and in- structions in the heater manual before operating a heated system.

1. The three-way ball valve (40) selects either fluid circulation or draining. To circulate fluid back to the pump, turn the handle toward the CIRC end of the valve.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 14.

8. Relieve the pressure, then install the spray tip in the gun.
2. To drain the fluid, turn the handle toward the DRAIN end.

15 307932

Page 16 of the Graco 253697 user manual — Flushing
Page 16 · click to enlarge
Page 16

Operation/Maintenance

Shutdown and Care of the Pump

CAUTION

Never leave water or water-base fluid in the pump overnight. If you are pumping water-base fluid, flush with water first, then with a rust inhibitor such as mineral spirits. Relieve the pressure, but leave the rust inhibitor in the pump to protect the parts from corrosion.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 14.

For overnight shutdown, stop the pump at the bottom of its stroke to prevent fluid from drying on the ex- posed displacement rod and damaging the throat packings. Relieve the pressure.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 14.

Always flush the pump before the fluid dries on the displacement rod. See Flushing below.

Flushing

1. Relieve the pressure.
2. Remove the spray tip from the gun.

FIRE AND EXPLOSION HAZARD Before flushing, read the section FIRE OR EXPLOSION HAZARD on page 4. Be sure the entire system and flushing pails are properly grounded. Refer to Grounding on page 5.

3. Hold a metal part of the gun firmly to the side of a grounded metal pail.
4. Start the pump. Always use the lowest possible fluid pressure when flushing.
5. Trigger the gun.

Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts in your system. Check with your fluid manufacturer or supplier for recommended flushing fluids and flushing frequency. Always flush the pump before fluid dries on the dis- placement rod.

6. Flush the system until clear solvent flows from the gun.
7. Relieve the pressure.

16 307932

Page 17 of the Graco 253697 user manual — A A
Page 17 · click to enlarge
Page 17

Parts

Model 245187, 33:1, Series B

Model 253697, 28:1, Series A

Ref No. Part No. Description Qty

Ref No. Part No. Description Qty

1 245117 33:1 BULLDOG PUMP (245187 only) See 309340 for parts 1 245167 28:1 BULLDOG PUMP (253697 only) See 309340 for parts 1 2 206294 BRACKET, wall, pump 1 3 161800 NIPPLE, reducing; 3/4 npt x 3/8 npsm 1 4 218029 FLUID FILTER See 307273 for parts 1 5 100509 PLUG, pipe, sq hd; 1/4 npt 4 6 150286 ADAPTER; 3/8 npt (m x f) 1 7 210658 DRAIN VALVE; 3/8 npt(mbe) See 306861 for parts 1 8 206197 AIR REGULATOR See 308168 for parts 1 9 155665 UNION, adapter, straight; 3/8 npt(m) x 3/8 npsm(f) swivel 1 10 157705 ADAPTER, 1/4 npt(m) x 3/8 npsm(f) swivel 1 11 116401 ELBOW, street, 90; (f) 1 11–1/2 x 1–1/4 11–1/2(f); zinc-plated malleable iron 1 12 116402 ADAPTER; (f) 1 11–1/2 x 1–1/4 11–1/2(f); zinc–plated malleable iron 1 14 113269 BLEED VALVE, red-handled; 1/2 npt (m x f) 1 15 206205 MANIFOLD, air; 3/4 npsm(f) 1 16 100960 GAUGE, air 1 17 100840 ELBOW, street; 90; 1/4 npt (m x f) 1 18 100403 PLUG, pipe; 1/8 npt 1 19 214952 HOSE, air; 3/4 in. (19 mm) ID; 3/4 npt(m) x 1/2 npt(m); 16 in. (406 mm) long 1

20 100101 SCREW, cap, hex hd; 3/8–16 x 1 in. (25 mm) long 4 21 100133 WASHER, spring lock; 3/8 in. 4 22 100131 NUT, hex; 3/8–16 5 24 244516 HOSE, siphon; nylon; 1 in. npt; 6 ft (1.8 m) long 1 25 206266 SUCTION TUBE; 3/4 npt(f) 1 43 206994 THROAT SEAL LIQUID 8 oz (0.5 liters); not shown 1 45 237569 GROUND WIRE 1 47 100322 WASHER, lock; 3/8 in. 2 52 100474 COUPLING, pipe 1 53 158555 NIPPLE, reducing; 1 npt x 3/4 npt 1 54 158586 BUSHING, 1 x 3/4 1

A A

AIR REGULATOR DETAIL

4 See Detail at left.

17 307932

Page 18 of the Graco 253697 user manual — Parts
Page 18 · click to enlarge
Page 18

Parts

Model 245185, Series A (240 Volt Heater) Model 245186, Series A (480 Volt Heater)

Ref No. Part No. Description Qty

Ref No. Part No. Description Qty

1 245117 33:1 BULLDOG PUMP See 309340 for parts 1 2 206294 BRACKET, wall, pump 1 4 218029 FLUID FILTER See 307273 for parts 1 5 100509 PLUG, pipe, sq hd; 1/4 npt 4 6 150286 ADAPTER; 3/8 npt (m x f) 1 7 210658 DRAIN VALVE; 3/8 npt(mbe) See 306861 for parts 1 8 206197 AIR REGULATOR See 308168 for parts 1 11 116401 ELBOW, street, 90; (f) 1 11–1/2 x 1–1/4 11–1/2(f); zinc-plated malleable iron 1 12 116402 ADAPTER; (f) 1 11–1/2 x 1–1/4 11–1/2(f); zinc–plated malleable iron 1 14 113269 BLEED VALVE, red-handled; 1/2 npt (m x f) 1 15 206205 MANIFOLD, air; 3/4 npsm(f) 1 16 100960 GAUGE, air 1 17 100840 ELBOW, street; 90; 1/4 npt (m x f) 1 18 100403 PLUG, pipe; 1/8 npt 1 19 214952 HOSE, air; 3/4 in. (19 mm) ID; 3/4 npt(m) x 1/2 npt(m); 16 in. (406 mm) long 1 20 100101 SCREW, cap, hex hd; 3/8–16 x 1 in. (25 mm) long 4 21 100133 WASHER, spring lock; 3/8 in. 4 22 100131 NUT, hex; 3/8–16 5 24 244516 HOSE, siphon; nylon; 1 in. npt; 6 ft (1.8 m) long 1 25 206266 SUCTION TUBE; 3/4 npt(f) 1 26* 183982 BRACKET, wall, heater 2 27* 175013 NIPPLE; 3/4 npt 1 28* 166590 ELBOW, street, 3/4 npt(m x f) 1 29* 235132 CHECK VALVE; 3/4 npt(m) x 3/4 npt(f); includes items 29a–29e 1 29a 235133 . SEAT, valve 1 29b 111691 . O-RING; fluoroelastomer 1 29c 101190 . BALL 1 29d 181492 . GUIDE, ball 3 29e 187861 . HOUSING, valve 1 30* 158556 COUPLING, hex pipe; 1/2 npt(f) x 3/4 npt(f) 1 31* H55003 HOSE, fluid; nylon; 1/2 in. (12.7 mm) ID; 1/2 npt (fbe); 3 ft (0.9 m) long 3 32* 158683 ELBOW, 90; 1/2 npt (m x f) 2 33* 156849 NIPPLE; 3/8 npt 2

34* 159801 UNION, adapter, 90; 3/8 npt(f) x 1/2 npsm(f) swivel 2 35* 165198 NIPPLE, reducing; 1/4 npt(m) x 3/8 npt(m) 1 36* 110110 SEALANT, pipe; sst; 6 ml (not shown) 1 37 207296 HOSE, fluid; PTFE tube w/braid cover; 13/32 in. ID; cpld 3/8 npt (mbe); 31 in. (0.8 m) long 1 38 207411 UNION, adapter, 45; 3/8 npt(f) x 3/8 npsm(f) swivel 1 39 100176 BUSHING, hex; 1/4 npt(f) x 3/8 npt(m) 2 40 214711 BALL VALVE, three-way; 1/4 npt(m); See 306861 for parts 1 41 205169 HOSE, fluid; nylon; 3/8 in. ID; 3/8 npsm (fbe); 3 ft (0.9 m) long 1 42 167905 TUBE, return; 3/8 npt(m) 1 43 206994 THROAT SEAL LIQUID 8 oz (0.5 liters); not shown 1 44 245863 VISCON HP HEATER, 240 Volt; used on Model 245185 see manual 309524 2 245864 VISCON HP HEATER, 480 Volt; used on Model 245186 see manual 309524 2 45 237569 GROUNDING WIRE AND CLAMP 1 47 100322 WASHER, lock; 3/8 in. 2 48 500566 TEE; 1 in. female 1 49 100615 BUSHING; 3/4 npt(m) x 1/4 npt(f) 1 51 290074 LABEL, warning 1 52 100474 COUPLING, pipe 1 53 158555 NIPPLE, reducing; 1 npt x 3/4 npt 1 54 158585 FITTING, nipple 1 55 158586 BUSHING; 1 npt(m) x 3/4 npt(f) 1 62 502265 BUSHING, reducer, pipe 2 64* 158491 NIPPLE, 1/2 npt 3

* Included in Dual Heater Mounting Kit 222311. Required to convert Model 245187 or 253697 Sprayers to a heated unit. The heaters are not included in this kit and must be ordered separately, by desired voltage (see page 10).

Included in Circulating Kit 222312. Required to convert Model 245187 or 253697 Sprayers to a circulating unit.

Replacement Danger and Warning labels, tags and cards

are available at no cost.

18 307932

Page 19 of the Graco 253697 user manual — Parts
Page 19 · click to enlarge
Page 19

Parts

Model 245185, Series A (240 Volt Heater) Model 245186, Series A (480 Volt Heater)

Graco 253697 — Parts diagram (page 19)
Fig. 3 · Parts

Connect to the main fluid supply line to the guns.

35* · 19 307932

Page 20 of the Graco 253697 user manual — Mounting Hole Layout
Page 20 · click to enlarge
Page 20

Mounting Hole Layout

M8 or 5/16 in. diameter holes for heater wall brackets (or use brackets

as templates to mark wall).

12.375 in. (314 mm)

6 in. (152 mm)

15 in. (381 mm)

5 in. (127 mm)

7.375 in. (187 mm)

8.5 in. (216 mm)

6 in. (152 mm)

7/16 in. diameter holes for pump wall bracket (mount 5 ft [1.5 m] above floor; refer to 306783 for instructions).

20 307932

Page 21 of the Graco 253697 user manual — Technical Data
Page 21 · click to enlarge
Page 21

Technical Data

Maximum fluid working pressure Model 245187: 3300 psi (228 bar, 22.8 MPa) Models 245185, 245186: 3000 psi (207 bar, 20.7 MPa) Model 253697: 2800 psi (193 bar, 19.3 MPa)

Maximum air input pressure Models 245187, 253697: 100 psi (7 bar, 700 kPa) Model 245185, 245186: 90 psi (6 bar, 600 kPa)

Ratio Models 245185, 245186, 24518733:1 Model 253697: 28:1

Pump performance data See pump manual 309340

Air consumption data See pump manual 309340

Maximum operating temperature Models 245187, 253697 (ambient temperature applications): 180F (82C) Models 245185, 245186 (heated applications): 205F (93C)

Air inlet size 3/4 npsm(f)

Fluid outlet size (at fluid filter) 3/8 npsm(f)

Fluid inlet size 1–1/2 in. npt(f)

Weight Models 245187, 253697135 lb (61 kg) Models 245185, 245186: 210 lb (95 kg)

Wetted parts Pump: See pump manual 309340 Fluid Filter: See manual 307273 Heater: See manual 309524 Suction Hose and Tube: LDPE, Carbon Steel Fluid Fittings: Carbon Steel, Wrought Steel/Plated, Malleable Iron/Plated

Sound Pressure Levels (tested at 1 meter from motor)

Graco 253697 — Technical Data diagram (page 21)
Fig. 4 · Technical Data

Standard Bulldog 82.4 dB(A) 87.3 dB(A) 88.5 dB(A) 90.0 dB(A)

Sound Power Levels (tested in accordance with ISO 9614)

Graco 253697 — Technical Data diagram (page 21)
Fig. 5 · Technical Data

Standard Bulldog 91.6 dB(A) 95.9 dB(A) 97.4 dB(A) 98.1 dB(A)

Category Data · 21 307932

Page 22 of the Graco 253697 user manual — MM 307932
Page 22 · click to enlarge
Page 22

Graco Standard Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Graco Information

TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers

to identify the distributor closest to you:

1–800–328–0211 Toll Free 612–623–6921 612–378–3505 Fax

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

MM 307932

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea

www.graco.com 307932 12/1988, Revised 06/2006

22 307932

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Graco 253697

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 253697

Be the first to ask — other owners or our team will answer.

Original document

Graco 253697 manual PDF

22 pages·553 KB·Water Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…