Husky 750 and Husky 2000 Surge Suppressors
308703G
For control of pressure fluctuations and acceleration loss, preventing cavitation. For professional use only.
120 psi (0.8 MPa, 8 bar) Maximum Air Input Pressure 120 psi (0.8 MPa, 8 bar) Maximum Fluid Working Pressure
See the Model Numbers on page 12.
06887 06891 06888 06892 06894

Symbols
Symbols 2 Warnings 2 Installation 4 Operation 7 Troubleshooting 9 Service 10 Model Numbers 12 Parts Matrix 13 Parts Drawings 14 Dimensions 16 Technical Data 17 Graco Standard Warranty 18 Graco Information 18
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
This equipment is for professional use only.
Read all instruction manuals, tags, and labels before operating the equipment.
Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
Check equipment daily. Repair or replace worn or damaged parts immediately.
Do not exceed the maximum working pressure of the lowest rated component in your system. This equipment has a 120 psi (0.8 MPa, 8 bar) maximum working pressure and 120 psi (0.8 MPa, 8 bar) maximum incoming air pressure.
Solvent Compatibility:
– Use fluids and solvents which are compatible with the equipment wetted parts.
– Use only compatible solvents to clean all plastic parts. Many solvents can degrade plastic parts to the point where they could fail.
Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
Do not use hoses to pull equipment.
Do not lift pressurized equipment.
Comply with all applicable local, state, and national fire, electrical, and safety regulations.
Do not operate outside the minimum and maximum operating temperature of your surge suppressor unit. See Minimum and Maximum Operating Temperatures on page 7.

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
Know the specific hazards of the fluid you are using.
Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.
Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.
Pipe and dispose of the exhaust air safely, away from people, animals, and food handling areas. If the diaphragm fails, the fluid is exhausted along with the air.
Never use an acetal pump to pump acids. Take precautions to avoid acid or acid fumes from contacting the pump housing exterior. Stainless steel parts will be damaged by exposure to acid spills and fumes.
Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.
Charge the surge suppressor with compressed air or nitrogen only. Do not use oxygen. Such use could result in an explosion.
Never pump flammable fluids with polypropylene units.
Ground the equipment. Refer to Grounding on pages 4 and 5.
Never use a polypropylene pump or surge suppressor with non-conductive flammable fluids as specified by your local fire protection code. Refer to Grounding on pages 4 and 5 for additional information. Consult your fluid supplier to determine the conductivity or resistivity of your fluid.
If there is any static sparking or you feel an electric shock while using this equipment, stop pump- ing immediately. Do not use the equipment until you identify and correct the problem.
Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being pumped.
Pipe and dispose of the exhaust air safely, away from all sources of ignition.
Keep the work area free of debris, including solvent, rags, and gasoline.
Electrically disconnect all equipment in the work area.
Extinguish all open flames or pilot lights in the work area.
Do not smoke in the work area.
Do not turn on or off any light switch in the work area while operating or if fumes are present.
Do not operate a gasoline engine in the work area.

FIRE AND EXPLOSION HAZARD When pumping flammable fluids, the surge suppressor must be grounded. Before pumping, ground the system as explained below. Also read the section FIRE OR EXPLOSION HAZARD on page 3.
Polypropylene surge suppressors are not conductive. Attaching the ground wire to the grounding lug grounds only the clamp or flange (see Fig. 1). When pumping conductive flammable fluids, always ground the entire fluid system by making sure the fluid has an electrical path to a true-earth ground.
To reduce the risk of static sparking, ground the surge suppressor and all other equipment in the pumping area. Check your local electrical code for detailed grounding instructions for your area and type of equip- ment. Ground all of this equipment:
Surge suppressor: Attach a ground wire to the grounding lug (2) as shown in Fig. 1. Connect the clamp end of the ground wire to a true earth ground. To order a ground wire and clamp, order Part No. 222011.
Air compressor: Follow the manufacturer’s recommendations.
Solvent pails used when flushing: Follow your local code. Use only grounded metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.
Fluid supply container: Follow your local code.

Grounding a Surge Suppressor
A Husky pump B Husky surge suppressor H Fluid drain valve (required) S Dispense valve T Fluid drain line W Surge suppressor ground wire (required)
See page 4 for installation instructions. Y Air motor ground wire (required) Z Container ground wire (required)

Hose must be conductive.
Dispense valve nozzle must be in contact with the container.


The installations in Fig. 2 are guides for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.
Be sure the mounting surface can support the weight of the pump, surge suppressor, hoses, and accessories, and the stress caused during operation.
Mount the surge suppressor as close to the pump discharge as possible and upstream of equipment such as valves, meters, filters, and so on. The surge suppressor should be installed within 10 pipe diameters of the pump discharge.
If you use a flexible connector from the pump to the piping system, the surge suppressor should be mounted to the pump discharge manifold, and the flexible connector should be attached to the surge suppressor tee and system piping.
Because pressure is equal in all directions, the surge suppressor can be installed in any position, but the vertical position shown in Fig. 2 is recommended for better draining. Fluids with high specific gravity or high viscosity, settling of heavy material, and possible air entrapment further limit the mounting positions other than those shown in Fig. 2.
Connecting Manual Models
Connect the 1/4-in air supply hose to the 1/4 npt connection on the top of the surge suppressor.
Connect the 1/4-in air supply hose to the brass one-way check valve on the top of the surge sup- pressor.
The air pressure to the surge suppressor must be greater than or equal to the pump discharge and/or system pressure. For equal air pressure, you can use a tee in the pump’s air supply line to run an air line to the surge suppressor.
The air pressure to the surge suppressor must be greater than or equal to the pump discharge and/or system pressure. For equal air pressure, you can use a tee in the pump’s air supply line to run an air line to the surge suppressor.
For models with elastomer bladders, the tee must be located in the pump’s air supply line before any pump controller or instrumentation such as the filter, regulator, or pump control valve.
For models with PTFE bellows, the tee must be located in the pump’s air supply line after any pump controller or instrumentation such as the filter, regulator, or pump control valve.
The tee must be located in the pump’s air supply line before any pump controller or instrumentation such as the filter, regulator, or pump control valve.

Minimum and Maximum Operating Temperatures
PRESSURIZED EQUIPMENT HAZARD The equipment stays pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, accidental spray from the dispensing device, or splashing fluid, follow this procedure whenever you
Find the minimum and maximum operating tempera- tures for your surge suppressor unit in the list below. These temperature limits are stated at zero gauge pressure.
Are instructed to relieve pressure Stop pumping Check, clean, or service any system equipment Install or clean fluid nozzles
239095 10 to 180 F (–12 to 82 C) 239096 32 to 175 F (0 to 79 C) 239121 40 to 175 F (4 to 79 C) 239122 32 to 175 F (0 to 79 C) 239123 40 to 220 F (4 to 104 C) 239124 –10 to 350 F (–23 to 176 C)
For automatic surge suppressors, remove the air pressure gauge, and allow any residual air pressure to escape.
For manual surge suppressors, adjust the regulator to relieve the air pressure by dialing down the pressure.
239092 32 to 175 F (0 to 79 C) 239093 32 to 175 F (0 to 79 C) 239126 40 to 175 F (4 to 79 C) 239127 32 to 175 F (0 to 79 C) 239128 40 to 175 F (4 to 79 C)
TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
Read TOXIC FLUID HAZARD on page 3.
Manual Husky 750 239090 10 to 180 F (–12 to 82 C) 239091 32 to 175 F (0 to 79 C) 239129 40 to 175 F (4 to 79 C) 239130 32 to 175 F (0 to 79 C) 239131 40 to 220 F (4 to 104 C) 239132 –10 to 350 F (–23 to 176 C)
Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manu- als. Read the fluid and solvent manufacturer’s warnings.
FIRE AND EXPLOSION HAZARD Charge the surge suppressor with compressed air or nitrogen only. Do not use oxygen.
Never pump flammable fluids with polypropylene units.
239087 32 to 175 F (0 to 79 C) 239088 32 to 175 F (0 to 79 C) 239134 40 to 175 F (4 to 79 C) 239135 32 to 175 F (0 to 79 C) 239136 40 to 175 F (4 to 79 C)
Charging the surge suppressor with oxygen or pumping flammable fluids with polypropylene units could cause a fire or an explosion.

For optimum performance, surge suppressors should be charged to a pressure 2 to 10 psi (0.01 to 0.07 MPa, 0.1 to 0.7 bar) lower than system pressure.
CAUTION
Manual surge suppressors must be charged before you start pumping. Failure to do so could result in the internal air valve puncturing or rupturing the bladder.
Automatic surge suppressors must have the air supply connected before you start pumping. Failure to do so could result in the internal air valve puncturing or rupturing the bladder.
Before you start the pump, charge the surge suppres- sor with air line pressure.
The air pressure gauge (1) (See Parts Drawings on pages 14 and 15) on automatic surge suppressors remains at zero pressure even after the air line is connected, because the surge suppressor only allows air into the air chamber when it is required to dampen pulsation. After the air supply line is attached to the one-way check valve (8) and air is available, you can start the pump. No further adjustments are necessary.
Automatic Models · Manual Models ·

Relieve the pressure before checking or servicing the equipment.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.
Check all possible problems and causes before disas- sembling the pump.

Replacing Bladder or Bellows
Normal life for bladders can be from a few months to several years, depending upon the harshness of the application. Below are common reasons for failed bladders or bellows:
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.
Chemical attack: Check chemical compatibility charts. Consult your Graco distributor.
Cut bladder or bellows: Check for sharp objects that may have been introduced into the surge suppressor through pumped fluid.
Make sure that you properly orient the parts: Install rubber bladders with the concave side facing the top housing, as shown in the Parts Drawings on page 14.
Install PTFE bellows with the concave side facing the bottom housing, as shown in Model No. 239126 in the Parts Drawings on page 15. Install the PTFE encapsulated fluo- roelastomer o-rings on each side of the bel- lows.
Insufficient compressed air charge in surge sup- pressor during operation: See Charging and Startup on page 8.
Surge suppressor too small for the pump: An undersized surge suppressor will have premature bladder failure. Contact your Graco distributor for assistance in ensuring that you have the correct size surge suppressor.

Torque Table Find the proper torque specifications for your surge suppressor unit in the table below. These are the torques to which the clamp band, ring flange, or bolts in bolted units need to be tightened.

Polypropylene Wetted Bottom Housing and Non-Wetted Top Housing
239096 with Buna–N bladder 239121 with PTFE bellows 239122 with fluoroelastomer bladder
Stainless Steel Wetted Bottom Housing and Non-Wetted Top Housing
239095 with Buna–N bladder 239123 with PTFE bellows 239124 with fluoroelastomer bladder
Stainless Steel Wetted Bottom Housing, Polypropylene Non-Wetted Top Housing
239093 with Buna–N bladder 239126 with PTFE bellows 239127 with fluoroelastomer bladder
Polypropylene Wetted Bottom Housing and Non-Wetted Top Housing
239092 with Buna–N bladder 239128 with PTFE bellows
Polypropylene Wetted Bottom Housing and Non-Wetted Top Housing
239091 with Buna–N bladder 239129 with PTFE bellows 239130 with fluoroelastomer bladder
Stainless Steel Wetted Bottom Housing and Non-Wetted Top Housing
239090 with Buna–N bladder 239131 with PTFE bellows 239132 with fluoroelastomer bladder
Stainless Steel Wetted Bottom Housing, Polypropylene Non-Wetted Top Housing
239088 with Buna–N bladder 239134 with PTFE bellows 239135 with fluoroelastomer bladder
Polypropylene Wetted Bottom Housing and Non-Wetted Top Housing
239087 with Buna–N bladder 239136 with PTFE bellows

Replacement Parts for Husky 750 and Husky 2000 Surge Suppressors, Series A
Manual Husky 2000 is 1 for every model. The X’s indicate the parts that are included in each model.
2 3 9 0 9 5
2 3 9 0 9 6
2 3 9 1 2 1
2 3 9 1 2 2
2 3 9 1 2 3
2 3 9 1 2 4
2 3 9 0 9 2
2 3 9 0 9 3
2 3 9 1 2 6
2 3 9 1 2 7
2 3 9 1 2 8
2 3 9 0 9 0
2 3 9 0 9 1
2 3 9 1 2 9
2 3 9 1 3 0
2 3 9 1 3 1
2 3 9 1 3 2
2 3 9 0 8 7
2 3 9 0 8 8
2 3 9 1 3 4
2 3 9 1 3 5
2 3 9 1 3 6
Ref No. Part No. Description
1 100960 GAUGE, air press.;200 psi (1.4 MPa, 14 bar); 1/4 npt
X
2 104029 LUG, grounding X
3 104582 WASHER, tab X
4 110318 REGULATOR, air; 1/4 npt X
5 110319 GAUGE, air press., 200 psi (1.4 MPa, 14 bar); 1/8 npt
X
6 113872 CLAMP, band; SST X
7 113878 BELLOWS, PTFE with o-ring kit
8 113879 VALVE, check X
9 113880 CLAMP, band; SST X
10 113881 FLANGE, ring, with fasteners X
11 113882 VALVE ASSY, automatic for rubber bladders
13 113884 FLANGE, ring, with fasteners X X
14 113885 BLADDER, Buna–N X
15 113886 BELLOWS; PTFE with o-ring kit
16 113887 VALVE ASSY, automatic for rubber bladders
18 113889 BLADDER; fluoroelastomer X X
19 113890 BLADDER; fluoroelastomer X
20 113891 BLADDER, Buna–N X
21 113923 BOLT, WASHER, NUT SET X
22 186620 STICKER, grounding symbol X
24 290306 LABEL, identification X
25 290322 LABEL, warning X
26 290323 LABEL, product X
27 290324 LABEL, product X
28 290384 LABEL, caution X
Non-Replacement Parts for Husky 750 and Husky 2000 Surge Suppressors, Series A
A Top housing (See Model Numbers list on page 12 for housing material of each model) B Bottom housing (See Model Numbers list on page 12 for housing material of each model) C Close nipple, SST; 1/4”

(see Parts Matrix on page 13)
24, 25, 26, 28 hanging on regulator
24, 25, 26, 28 hanging on regulator
06890 06889 B B
Model 239091 Model 239090

(see Parts Matrix on page 13)
24, 25, 27, 28 hanging on regulator
A
24, 25, 27, 28 hanging on gauge
B
Model 239088 Model 239126

239088 shown Automatic Husky 2000
23.25 in. (591 mm)
22.50 in. (572 mm)
20.25 in. (514 mm)
20.25 in. (514 mm)
8.5 in. (216 mm)
8.5 in. (216 mm)
2 npt fluid inlet
2 npt fluid inlet
239091 shown Automatic Husky 750
12.5 in. (318 mm)
13.25 in. (337 mm)
10.0 in. (254 mm)
10.0 in. (254 mm)
6.0 in. (152 mm)
3/4 npt fluid inlet 3/4 npt fluid inlet 6.0 in. (152 mm)
239126 shown · 239096 shown ·

Maximum air input pressure 120 psi (0.8 MPa, 8 bar) Air line connection 1/4 npt Fluid Inlet size
Husky 2000 models 2 npt Husky 750 models 3/4 npt Wetted and non-wetted parts See the Model Numbers list on page 12 Weight
Models 239091, 239096, 239121, 239122, 239129, and 239130 9 lb (4.1 kg) Models 239090, 239095, 239123, 239124, 239131, and 239132 16 lb (7.3 kg) Models 239088, 239093, 239126, 239127, 239134, and 239135 36 lb (16.3 kg) Models 239087, 239092, 239128, and 239136 18 lb (8.2 kg)

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accor- dance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the distributor closest to you:
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 308703
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 1996, Graco Inc. is registered to ISO 9001
www.graco.com Revised 06/2010
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Surge suppressor does not hold pressure. | Manual or automatic models: –Leaking threaded connections –Loose flange bolts or clamp –Failed bladder or bellows –Blocked air line to unit | –Check all threads for leaks. –See Torque Table, page 11. –See Bladder Failure, page 10. –Use 1/4-in air line. | p.9 |
| Surge suppressor does not hold pressure. | Automatic models only: –One-way valve at air inlet is installed backwards. –Gauge shows no pressure, and pump is not running. | –Arrow should point toward surge suppressor. –Pressure does not register on gauge until pump is started. | p.9 |
| Surge suppressor does not hold pressure. | Manual models only: –Faulty regulator | –Check regulator. | p.9 |
| Dampening effect of surge suppressor is not sufficient. | Surge suppressor installed incorrect distance from pump | Surge suppressor should be installed within 10 pipe diameters of pump discharge. | p.9 |
| Dampening effect of surge suppressor is not sufficient. | Improper pressure charge | See Charging and Startup, page 8. Surge suppressor pressure should be 2 to 10 psi (0.01 to 0.07 MPa, 0.1 to 0.7 bar) lower than system pressure. | p.9 |
| Dampening effect of surge suppressor is not sufficient. | Surge suppressor does not hold pressure charge. | See surge suppressor does not hold pressure in PROBLEM column. | p.9 |
| Dampening effect of surge suppressor is not sufficient. | Failed bladder or bellows | See Bladder Failure, page 10. | p.9 |
| Dampening effect of surge suppressor is not sufficient. | Surge suppressor too small for pump | Install larger surge suppressor. | p.9 |
| Dampening effect of surge suppressor is not sufficient. | Automatic models only: Plugged automatic valve | Remove pressure from surge suppressor, and check automatic valve for proper operation as follows: 1. Leave air line attached to top half of surge suppressor. 2. Fill top of surge suppressor with enough water to cover automatic valve. There should be no bubbles. 3. Dump water out, and gently push automatic valve. Air should flow. 4. Replace automatic valve if it is defective. | p.9 |
| There is leaking around surge suppressor fluid inlet. | PTFE sealing tape or paste is needed on threads of fluid inlet. | Apply PTFE tape or paste to threads. Do not overtighten plastic models. Hand tightening is recommended. | p.9 |