Table of Contents 27 sections INSTRUCTIONS–P ARTS LIST 308–460 · Rev. A · 30:1 PRESIDENT STAINLESS STEEL, CART MOUNTED AA200hs Air-Assisted Airless Spray Package · See the Data Sheet, 305–664, for application information · … ShowHide
Page 1 of the Graco 237-421 user manual — IMPORTANT
Page 1 · click to enlarge
Page 1

INSTRUCTIONS–P ARTS LIST 308–460

Rev. A

Graco 237-421 — Rev. A diagram (page 1)
Fig. 1 · Rev. A

This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

30:1 PRESIDENT STAINLESS STEEL, CART MOUNTED AA200hs Air-Assisted Airless Spray Package

Graco 237-421 — 30:1 PRESIDENT STAINLESS STEEL, CART MOUNTED AA200hs Air-Assisted Airless Spray Package diagram (page 1)
Fig. 2 · 30:1 PRESIDENT STAINLESS STEEL, CART MOUNTED AA200hs…

See the Data Sheet, 305–664, for application information

3000 psi (210 bar) Maximum System Working Pressure 100 psi (6.9 bar) Maximum Air Inlet Pressure

Model 237–421, Series A Complete package includes pump, AA200hs air-assisted airless gun with 411 spray tip, portable cart, 25 ft. (7.6 m) air and fluid hoses, air and fluid controls, and fluid feed.

IMPORTANT

This manual provides basic safety, installation and operation information for the package. For your safety, also read the component manuals supplied with this package before operating it.

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 COPYRIGHT 1994, GRACO INC.

Page 3 of the Graco 237-421 user manual — TOXIC FLUID HAZARD
Page 3 · click to enlarge
Page 3

WARNING WARNING

SKIN INJECTION HAZARD

Spray from the gun, hose leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause can also cause serious injury.

If a skin injection occurs, get emergency medical care at once. Do not treat as a simple cut. Tell the doctor exactly what fluid was injected.

Give the doctor this information: Injection into the skin is a traumatic injury. Treat the injury surgi- cally as soon as possible. Do not delay treatment to research toxicity. Toxicity is a concern with some exotic coatings injected directly into the blood stream. Consultation with a plastic surgeon or reconstructive hand surgeon may be advisable.

Do not point the spray gun at anyone or any part of the body.

Do not put hand or fingers over the spray tip.

Do not stop or deflect fluid leaks with your hand, body, glove or rag.

Do not “blow back” fluid; this is not an air spray system.

Always have the tip guard and the trigger guard on the spray gun when spraying.

Check the gun diffuser operation weekly. Refer to the gun manual.

Be sure the gun trigger safety operates before spraying the gun.

Lock the gun trigger safety when you stop spraying.

Follow the Pressure relief procedure on page 8 if the spray tip clogs and before cleaning, checking or servicing the equipment.

Tighten all fluid connections before each use.

Check the hoses, tubes and couplings daily. Replace worn or damaged parts immediately. Per- manently coupled hoses cannot be repaired.

Handle and route hoses and tubes carefully. Keep hoses and tubes away from moving parts and hot surfaces. Do not use the hoses to pull equipment. Do not expose Graco hoses to tempera- tures above 180F (82C) or below –40F (–40C).

TOXIC FLUID HAZARD

Improper handling of hazardous fluids or inhaling toxic fumes can cause extremely serious injury, even death, due to splashing in the eyes, ingestion, or bodily contamination.

Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container. Dispose hazardous fluid according to all local, state and national guidelines.

Wear appropriate clothing, gloves, eyewear and respirator.

Page 4 of the Graco 237-421 user manual — WARNING WARNING
Page 4 · click to enlarge
Page 4
WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor air ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. Ground the equipment and the object being sprayed. See Ground the system on 6. If there is any static sparking while using the equipment, stop spraying immediately. Identify and correct the problem. Provide fresh air ventilation to avoid the buildup of flammable vapors from solvent or the fluid being sprayed. Do not smoke in the spray area. Extinguish all open flames or pilot lights in the spray area. Do not turn on or off any light switch in the spray area. Electrically disconnect all equipment in the spray area. Keep the spray area free of debris, including solvent, rags and gasoline. Do not operate a gasoline engine in the spray area. EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction or start unexpectedly and result in serious injury. This equipment is for professional use only. Read all instruction manuals, tags, and labels before operating the equipment. Use the equipment only for its intended purpose. If you are in doubt about this, call Graco Technical Assistance at 1–800–543–0339. Do not alter or modify this equipment. Use only genuine Graco parts and accessories. Check equipment daily. Repair or replace worn or damaged parts immediately. Do not exceed the 3000 psi (210 bar) maximum working pressure at 100 psi (6.9 bar) maximum incoming air pressure of the pump, or the maximum working pressure of any accessory used with it. Do not move or lift pressurized equipment. Use fluids or solvents which are compatible with equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings. Fluid hoses must have spring guards on both ends to protect it from rupture caused by kinks or bends at or close to the couplings. Comply with all applicable local, state and national fire, electrical and other safety regulations. Do not touch the heater during operation; it is very hot. MOVING PARTS HAZARD Moving parts, such as the air motor piston located behind the air motor plates, which can pinch or amputate fingers. Never operate the equipment with the air motor plates removed. Keep clear of any moving parts when starting or operating the equipment.

Page 5 of the Graco 237-421 user manual — A
Page 5 · click to enlarge
Page 5

Setup

3. Bring an air line from your compressed air supply to the pump location. Be sure the air is dry and filtered. Install a bleed–type master air valve (A) upstream from the pump. Another master air valve (14) is supplied with the package. When the bleed–type master air valve is closed and the pump air regulator (8a) is opened, the valve relieves all air pressure to the system.
Graco 237-421 — Setup diagram (page 5)
Fig. 3 · Setup

This equipment is compatible with most water based materials. See the wetted parts in the Tech- nical Data section and your fluid and solvent manufacturer’s compatibility information.

4. Have a grounded metal waste pail available to use when draining the fluid filter .

I. Prepare the operator.

All persons who operate the system should be trained in the safe, efficient operation of all system compo- nents as well as the proper handling of the chemical coating. At a minimum, all operators should thoroughly read the safety, installation and operation sections of this manual and the component manuals.

5. V entilate the spray booth.
Graco 237-421 — Setup diagram (page 5)
Fig. 4 · Setup

To prevent hazardous concentrations of toxic and/ or flammable vapors, spray only in a properly venti- lated spray booth. Never operate the spray gun unless ventilation fans are operating.

II. Prepare the site.

1. Use a minimum recommended 5 HP (3.7 kW) air compressor for ef ficient operation.

Check and follow all of the national, state and local codes regarding air exhaust velocity requirements.

2. Clear obstacles and debris that could hinder the operator’ s movement.

A

KEY

Graco 237-421 — A diagram (page 5)
Fig. 5

A Bleed-type master air valve Required for pump; order part no. 107–142, 1/4” npt(f) B Air filter. Order part no. 106–149, 1/2 npt(f) C Air supply line D Grounded 5 gallon metal pail E Air line moisture trap

1 30:1 President pump 3 Air-assisted airless spray gun 4 Spray tip 5 Fluid filter 6 Gun fluid hose 7 Gun air hose 8a Pump air regulator 8b Gun air regulator 14 Bleed–type air valve 30 Pump ground wire

Page 6 of the Graco 237-421 user manual — Setup
Page 6 · click to enlarge
Page 6

Setup

III. Unpack the system.

V. Ground the system.

1. In addition to the assembled components, the air and fluid hoses, gun and instruction manuals are packaged separately in the main shipping con - tainer . These are the manuals you should receive:

To reduce the risk of static sparking, ground the pump and all other equipment used or located in the spray area. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Ground all of this equipment. Also read FIRE OR EXPLOSION HAZARD on page 4.

308–106 30:1 ratio President pump 308–176 Air-assisted airless spray gun 307–273 Fluid filter 308–167 Air regulator 308–861 Ball valve 308–136 Cart

1. Pump : one end of the ground wire (30) is already connected to the air motor grounding lug. Connect the clamp end of the ground wire to a true earth ground.

IV. Connect the hoses and gun to the system. See Fig. 1.

2. Air and fluid hoses : use only grounded hoses with a maximum of 500 ft. (150 m) combined hose length to ensure grounding continuity .
1. Connect the blue fluid hose (6) between the fluid filter and the fluid inlet of the spray gun (3). These are 1/4–18 npsm(f) swivel fittings.
3. Air compressor : according to manufacturer ’ s recommendations.
2. Connect the red air hose (7) between the gun air regulator (8b) and the air inlet of the spray gun (3). These are 1/4–18 npsm(f) swivel fittings.
4. Spray gun: grounding is obtained through connection to properly grounded fluid hoses and pump.
3. V erify that all fittings throughout the system are tightened securely .
5. Fluid supply container: according to local code.
6. All solvent pails used when flushing , according to local code. Use only metal pails, which are con - ductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which inter - rupts the grounding continuity .

Page 7 of the Graco 237-421 user manual — System Component Information
Page 7 · click to enlarge
Page 7

System Component Information

I. How to use the air–assisted airless spray gun.

II. How to change the spray pattern direction.

1. Relieve the air and fluid pressure.

With an air-assisted airless spray gun, the spray tip shapes the fluid into a fan pattern. Air from the air cap further atomizes the fluid and completes the atomiza- tion of the paint tails into the pattern to produce a more uniform pattern.

2. Install a spray tip in the gun. Rotate the air cap (the spray tip rotates with it) to determine the direction of the spray pattern. See Fig. 3.

Vertical Spray Pattern Horizontal Spray Pattern

The spray gun has a built-in lead and lag operation. When triggered, the gun emits air before the fluid is discharged. When the trigger is released, the fluid stops before the air flow stops. This helps assure the spray is atomized and prevents fluid buildup on the air cap.

III. How to adjust the air regulators. See Fig. 4.

As you look at the system, the air regulator (8a) on the left regulates air to the gun and the air regulator (8b) on the right regulates air to the pump.

1. The fan pattern valve (E) can be used to reduce the pattern by about 25% of the total pattern width. As the valve is opened, the pattern will reduce slightly . The tip used designates the total width of the spray pattern.
1. Always open air regulators slowly to prevent surg - ing during startup.
2. T o open the regulator , which allows air to flow , turn the T–handle IN (clockwise). T urn the T–handle OUT (counterclockwise) to close off the air flow . Be sure the jam nut under the T–handle does not interfere with your adjustments. T ighten the jam nut to lock in the setting, if desired.
2. T o unlock the gun trigger safety, turn the safety so it is parallel with the trigger . T o lock the gun trigger safety , turn the safety to a right angle with the trig - ger . See Fig. 2.

UNLOCKED gun trigger safety

Graco 237-421 — System Component Information diagram (page 7)
Fig. 6 · System Component Information

LOCKED gun trigger safety

Graco 237-421 — System Component Information diagram (page 7)
Fig. 7 · System Component Information
Show 4 more labels / short text on this page
· · ·
Page 8 of the Graco 237-421 user manual — I. Pressure relief procedure
Page 8 · click to enlarge
Page 8

Operation

I. Pressure relief procedure

II. Flush the pump before the first use.

Graco 237-421 — I. Pressure relief procedure diagram (page 8)
Fig. 8 · I. Pressure relief procedure

Flush with a solvent compatible to your fluid. Consult the fluid manufacturer’s literature for recommenda- tions. See Flushing on page 10.

The system remains pressurized until pressure is manually relieved. To reduce the risk of serious injury, including skin injection from pressurized fluid or accidental spray from the gun, or injury due to splashing fluid in the eyes or on the skin, follow this procedure whenever you:

III. Prime the system. See Fig. 5.

1. Remove the air cap and spray tip from the gun.

are told to relieve pressure; stop spraying; check or service any system equipment; install, clean or change spray tips.

2. Close the filter drain valve (26).
3. Put the suction tube into the fluid supply container .
4. Make sure the air regulators (8a,8b) are closed.
1. Lock the gun trigger safety .
2. Close the bleed-type master air valves (A,14).
5. Open the master air valves (A,14).
3. Close the air regulators (8a,8b).
4. Unlock the gun trigger safety .
5. Hold a metal part of the gun firmly against a grounded metal waste pail. T rigger the gun to relieve pressure.
6. Slowly turn on the pump air regulator (8a) until the pump cycles slowly .
6. Lock the gun trigger safety .
7. Open the filter drain valve (26), having a container ready to catch the drainage. Close the drain valve.
7. Hold a metal part of the gun firmly against and aimed into the grounded metal waste pail. T rigger the gun while increasing pressure at the pump air regulator (8a) just enough to purge the air and storage solvent from the system. When new fluid comes from the gun, release the trigger . Lock the gun trigger safety .

If you suspect that the spray tip or hose is completely clogged or that pressure has not been fully relieved, very slow loosen the tip retaining nut or hose end cou- pling and relieve pressure gradually. Clean the tip or hose obstruction.

Graco 237-421 — I. Pressure relief procedure diagram (page 8)
Fig. 9 · I. Pressure relief procedure

A Bleed-type master air valve 3 Air-assisted airless spray gun 8a Pump air regulator 8b Gun air regulator 14 Bleed–type air valve 26 Filter drain valve

Page 9 of the Graco 237-421 user manual — CAUTION
Page 9 · click to enlarge
Page 9

Operation

IV. Set the fluid and air pressure. 1. Install the spray tip and air cap on the gun.

V. You are now ready for production spraying.

2. Adjust the pump air pressure regulator until the pressure shown on the fluid filter gauge is about 900 psi (63 bar) . This should require approximately 30 psi (2.1 bar) air pressure to the pump.

CAUTION

When using catalyzed fluids, observe the pot life as recommended by the fluid manufacturer. Always flush the system before the pot life has expired to prevent dried fluid which may be difficult to clean out and may damage the system.

3. T est spray a pass or stationary horizontal pattern. Hold the gun 10 to 12 in. (250 to 300 mm) from the paper . Stripes in the outer edges of the pass or spots at the ends of the stationary pattern are likely at this point.

VI. When to shut down the system.

Shut down the system at the end of the work shift and before checking, adjusting, cleaning or repairing the system. Always follow the Pressure relief procedure on page 8.

4. Partially trigger the gun so only air is emitted. Set the gun air regulator to 20 psi (1.4 bar).
5. Retest the spray pattern. T rigger the gun and adjust the gun’ s air control valve (C) to add air to the aircap and to eliminate stripes or spots. If there are no stripes or spots, you are ready to start spraying.
6. If there are stripes or spots in the spray pattern, raise the pump air pressure until you raise the fluid outlet pressure by about 100 psi (6.9 bar) and try again. Continue to raise the fluid pressure in 100 psi (6.9 bar) increments until the pattern is full and clean. Do not exceed 100 psi (6.9 bar) incoming air pressure or 3000 psi (210 bar) fluid working pressure.

This system has a maximum air working pressure of 100 psi (6.9 bar) which produces a maximum fluid working pressure of 3000 psi (210 bar). Higher pressure can cause the system to rupture or mal- function and result in serious injury.

Page 10 of the Graco 237-421 user manual — Flushing
Page 10 · click to enlarge
Page 10

Flushing

I. When to flush.

7. Slowly turn on the pump air regulator (8a) until the pump cycles slowly .

Before the first time use

When changing colors

8. Hold a metal part of the gun firmly against the grounded metal waste pail. T rigger the gun. Slowly increase the pump air regulator setting until the fluid flows freely . (Some air will spit from the gun until the fluid arrives.)

Before fluid can dry or settle out in a dormant sys- tem (observe the recommended fluid pot life on cat- alyzed fluids)

Before storing the system

9. Keeping the gun triggered, decrease the pump air regulator (8a) pressure as much as possible without stalling the pump, and pump out the solvent until air comes through the gun.

II. How to flush. See Fig. 6.

1. Relieve pressure. See page 8.
10. Repeat the procedure with clean solvent, if needed.
2. Remove the air cap and spray tip before flushing.
11. Release the trigger and lock the gun trigger safety .
3. Unscrew the fluid filter (5) bowl. Remove the screen. See manual 307–273. Reinstall the bowl without the screen.
12. Close the master air valves (A,14). Fully close the pump air regulator (8a).
13. Open the drain valve (26), having a container ready to catch the drainage.
4. Put the suction tube into a grounded metal pail with about 1/2 gallon (2 liters) of a compatible solvent.
14. Remove the suction hose from the solvent and place it in an empty container .
5. Make sure the air regulators (8a,8b) are closed.
15. Clean the filter screen, air cap and spray tip sepa - rately . Reinstall the filter screen.
16. Thoroughly clean the inside and outside of the suction tube .
6. Open the master air valves (A,14).
Graco 237-421 — Flushing diagram (page 10)
Fig. 10 · Flushing

A Bleed-type master air valve 3 Air-assisted airless spray gun 5 Fluid filter 8a Pump air regulator 8b Gun air regulator 14 Bleed–type air valve 26 Filter drain valve

Page 11 of the Graco 237-421 user manual — Notes
Page 11 · click to enlarge
Page 11

Notes

Page 12 of the Graco 237-421 user manual — Parts
Page 12 · click to enlarge
Page 12

Parts

Model 237–421, Series A Includes items 1 to 34

Ref No. Part No. Description Qty

Ref No. Part No. Description Qty

1 223–843 PRESIDENT PUMP See 308–106 for parts 1 2 224–044 CART, portable See 308–136 for parts 1 3 223–283 AIR ASSISTED AIRLESS SPRAY GUN See 308–176 for parts 1 4 182–411 SPRAY TIP, 0.011 orifice, 8–10” (203–254 mm) fan width 1 5 223–160 FLUID FILTER See 307–273 for parts 1 6 236–074 FLUID HOSE, cpld 1/4 npt (fbe) 3/16” ID x 25’ (4.8 mm ID x 7.6 m) 1 7 210–867 AIR HOSE, cpld 1/4 npsm (fbe) 1/4” ID x 25’ (6.3 mm ID x 7.6 m) 1 8 104–267 AIR REGULATOR 0–125 psi (0–9 bar) range See 308–167 for parts 2 9 101–180 AIR PRESSURE GAUGE 0–200 psi (0–14 bar) 2 10 155–470 90 SWIVEL ADAPTER UNION, 1/2 npt(m) x 1/2 npsm(f) swivel 2 11 218–093 AIR HOSE, buna-S, cpld 1/2 npt(mbe), 1/2” ID x 22” (13 mm ID x 559 mm) 1 12 222–297 45 SWIVEL ADAPTER UNION, 1/2 npt(m) x 1/2 npsm(f) swivel 1 13 158–491 NIPPLE, 1/2 npt, 1.625” (41 mm) long 1 14 107–142 BLEED–TYPE AIR VALVE, 1/2 npt (f) 1

15 112–941 FLUID PRESSURE GAUGE 1 16 166–999 ELBOW, reducing street, 1/2 npt(m) x 1/4 npt(f) 1 17 162–453 NIPPLE, 1/4 npt x 1/4 npsm 1 18 236–075 SUCTION HOSE, 3/4 npt(mbe), 3/4” ID x 3.5’ (19 mm ID x 1.1 m) 1 19 112–191 SUCTION TUBE, 3/4 npt(f) 1 20 112–192 FLUID INTAKE ELBOW, 3/4 npt(f), 1 21 100–016 LOCKWASHER, 1/4” spring 2 22 100–270 CAPSCREW, hex hd, 1/4–20 x 5/8” (16 mm) long 2 23 235–208 SWIVEL UNION, 3/8 npt(m) x 3/8 npsm(f) 1 24 206–994 THROAT SEAL LIQUID, 8 oz. 1 25 188–089 NIPPLE, 3/8 npt x 3/8–18.6 sf 1 26 235–992 BALL VALVE, 3/8 npt x 1/4 npt (mbe) see 306–861 for parts 1 27 156–877 NIPPLE, 1/2 npt, 2.5” (63.5 mm) 2 28 188–595 PUMP MOUNTING PLATE 1 29 102–254 SCREW, hex hd, 1/4–20 x 7/8” (22 mm) long 2 30 237–569 GROUND WIRE and CLAMP 12 gauge (1.5 mm2), 25’ (7.6 m) 1 33 100–509 PLUG, 1/4 npt sq hd pipe 2 34 179–749 AIR MANIFOLD, 1/2 npt inlet, two 1/2 npt outlets 1 35 157–416 90 SWIVEL UNION 1 36 150–286 ADAPTER 1

Page 13 of the Graco 237-421 user manual — Parts
Page 13 · click to enlarge
Page 13

Parts

Graco 237-421 — Parts diagram (page 13)
Fig. 11 · Parts

Model 237–421, Series A Includes items 1 to 34

Page 14 of the Graco 237-421 user manual — Notes
Page 14 · click to enlarge
Page 14

Notes

Page 15 of the Graco 237-421 user manual — Notes
Page 15 · click to enlarge
Page 15

Notes

Page 16 of the Graco 237-421 user manual — Graco Phone Numbers
Page 16 · click to enlarge
Page 16

T echnical Data

Maximum Fluid Working Pressure 3000 psi (210 bar) Maximum Air Operating Pressure 100 psi (6.9 bar) Pump Air Consumption free flow: 20 scfm at 100 psi (0.56 m3/min at 6.9 bar) . . . Gun Air Consumption 5 scfm at 30 psi (0.14 m3/min at 2.1 bar) Wetted Parts

Pump 304/316/420/17–pH stainless steel, chrome plating,

tungsten carbide, PTFE, leather, UHMWPE Gun 303 stainless steel, carbide, UHMWPE CV75,

polyethylene, PTFE, Delrin Fluid filter 303/304/316 stainless steel, polyethylene, PTFE Fluid fittings 304/316 stainless steel Fluid hose nylon

The Graco Warranty and Disclaimers

WARRANTY

Graco warrants all equipment manufactured by it and bearing its name to be free from defects in fluid and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. As purchaser’s sole remedy for breach of this warranty, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment proven defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for, any malfunction, damage or wear caused by faulty installation, misap- plication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility with Graco equipment of structures, accessories, equipment or fluids not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or fluids not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claim. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in fluid or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor and transportation.

DISCLAIMERS AND LIMITATIONS

The terms of this warranty constitute purchaser’s sole and exclusive remedy and are in lieu of any other warranties (express or implied), including warranty of merchantability or warranty of fitness for a particular purpose, and of any non–contractual liabili- ties, including product liabilities, based on negligence or strict liability. Every form of liability for direct, special or consequential damages or loss is expressly excluded and denied. In no case shall Graco’s liability exceed the amount of the purchase price. Any action for breach of warranty must be brought within two (2) years of the date of sale.

EQUIPMENT NOT COVERED BY GRACO WARRANTY

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose, with respect to accessories, equipment, fluids, or components sold but not manufactured by Graco. These items sold, but not manufac- tured by Graco (such as electric motor, switches, hose, etc.) are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

Graco Phone Numbers

TO PLACE AN ORDER, contact your Graco distrib- utor, or call this number to identify the distributor closest to you: 1–800–367–4023 Toll Free

FOR TECHNICAL ASSISTANCE, service repair information or assistance regarding the application of Graco equipment: 1–800–543–0339 Toll Free

Sales Offices: Atlanta, Chicago, Dallas, Detroit, Los Angeles, Mt. Arlington (N.J.) Foreign Offices: Canada, England, Korea, Switzerland, France, Germany, Hong Kong, Japan

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 PRINTED IN U.S.A. 308–460 9/94

Ask about the Graco 237-421

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 237-421

Be the first to ask — other owners or our team will answer.

Original document

Graco 237-421 manual PDF

16 pages·1.1 MB·Paint Sprayer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…