This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

3000 psi (210 bar) Maximum System Working Pressure 100 psi (6.9 bar) Maximum Air Inlet Pressure
Model 237–421, Series A Complete package includes pump, AA200hs air-assisted airless gun with 411 spray tip, portable cart, 25 ft. (7.6 m) air and fluid hoses, air and fluid controls, and fluid feed.
This manual provides basic safety, installation and operation information for the package. For your safety, also read the component manuals supplied with this package before operating it.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 COPYRIGHT 1994, GRACO INC.


Spray from the gun, hose leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause can also cause serious injury.
If a skin injection occurs, get emergency medical care at once. Do not treat as a simple cut. Tell the doctor exactly what fluid was injected.
Give the doctor this information: Injection into the skin is a traumatic injury. Treat the injury surgi- cally as soon as possible. Do not delay treatment to research toxicity. Toxicity is a concern with some exotic coatings injected directly into the blood stream. Consultation with a plastic surgeon or reconstructive hand surgeon may be advisable.
Do not point the spray gun at anyone or any part of the body.
Do not put hand or fingers over the spray tip.
Do not stop or deflect fluid leaks with your hand, body, glove or rag.
Do not “blow back” fluid; this is not an air spray system.
Always have the tip guard and the trigger guard on the spray gun when spraying.
Check the gun diffuser operation weekly. Refer to the gun manual.
Be sure the gun trigger safety operates before spraying the gun.
Lock the gun trigger safety when you stop spraying.
Follow the Pressure relief procedure on page 8 if the spray tip clogs and before cleaning, checking or servicing the equipment.
Tighten all fluid connections before each use.
Check the hoses, tubes and couplings daily. Replace worn or damaged parts immediately. Per- manently coupled hoses cannot be repaired.
Handle and route hoses and tubes carefully. Keep hoses and tubes away from moving parts and hot surfaces. Do not use the hoses to pull equipment. Do not expose Graco hoses to tempera- tures above 180F (82C) or below –40F (–40C).
Improper handling of hazardous fluids or inhaling toxic fumes can cause extremely serious injury, even death, due to splashing in the eyes, ingestion, or bodily contamination.
Know the specific hazards of the fluid you are using.
Store hazardous fluid in an approved container. Dispose hazardous fluid according to all local, state and national guidelines.
Wear appropriate clothing, gloves, eyewear and respirator.



This equipment is compatible with most water based materials. See the wetted parts in the Tech- nical Data section and your fluid and solvent manufacturer’s compatibility information.
I. Prepare the operator.
All persons who operate the system should be trained in the safe, efficient operation of all system compo- nents as well as the proper handling of the chemical coating. At a minimum, all operators should thoroughly read the safety, installation and operation sections of this manual and the component manuals.

To prevent hazardous concentrations of toxic and/ or flammable vapors, spray only in a properly venti- lated spray booth. Never operate the spray gun unless ventilation fans are operating.
II. Prepare the site.
Check and follow all of the national, state and local codes regarding air exhaust velocity requirements.
KEY

A Bleed-type master air valve Required for pump; order part no. 107–142, 1/4” npt(f) B Air filter. Order part no. 106–149, 1/2 npt(f) C Air supply line D Grounded 5 gallon metal pail E Air line moisture trap
1 30:1 President pump 3 Air-assisted airless spray gun 4 Spray tip 5 Fluid filter 6 Gun fluid hose 7 Gun air hose 8a Pump air regulator 8b Gun air regulator 14 Bleed–type air valve 30 Pump ground wire

III. Unpack the system.
V. Ground the system.
To reduce the risk of static sparking, ground the pump and all other equipment used or located in the spray area. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Ground all of this equipment. Also read FIRE OR EXPLOSION HAZARD on page 4.
308–106 30:1 ratio President pump 308–176 Air-assisted airless spray gun 307–273 Fluid filter 308–167 Air regulator 308–861 Ball valve 308–136 Cart
IV. Connect the hoses and gun to the system. See Fig. 1.

I. How to use the air–assisted airless spray gun.
II. How to change the spray pattern direction.
With an air-assisted airless spray gun, the spray tip shapes the fluid into a fan pattern. Air from the air cap further atomizes the fluid and completes the atomiza- tion of the paint tails into the pattern to produce a more uniform pattern.
Vertical Spray Pattern Horizontal Spray Pattern
The spray gun has a built-in lead and lag operation. When triggered, the gun emits air before the fluid is discharged. When the trigger is released, the fluid stops before the air flow stops. This helps assure the spray is atomized and prevents fluid buildup on the air cap.
III. How to adjust the air regulators. See Fig. 4.
As you look at the system, the air regulator (8a) on the left regulates air to the gun and the air regulator (8b) on the right regulates air to the pump.
UNLOCKED gun trigger safety

LOCKED gun trigger safety


II. Flush the pump before the first use.

Flush with a solvent compatible to your fluid. Consult the fluid manufacturer’s literature for recommenda- tions. See Flushing on page 10.
The system remains pressurized until pressure is manually relieved. To reduce the risk of serious injury, including skin injection from pressurized fluid or accidental spray from the gun, or injury due to splashing fluid in the eyes or on the skin, follow this procedure whenever you:
III. Prime the system. See Fig. 5.
are told to relieve pressure; stop spraying; check or service any system equipment; install, clean or change spray tips.
If you suspect that the spray tip or hose is completely clogged or that pressure has not been fully relieved, very slow loosen the tip retaining nut or hose end cou- pling and relieve pressure gradually. Clean the tip or hose obstruction.

A Bleed-type master air valve 3 Air-assisted airless spray gun 8a Pump air regulator 8b Gun air regulator 14 Bleed–type air valve 26 Filter drain valve

IV. Set the fluid and air pressure. 1. Install the spray tip and air cap on the gun.
V. You are now ready for production spraying.
When using catalyzed fluids, observe the pot life as recommended by the fluid manufacturer. Always flush the system before the pot life has expired to prevent dried fluid which may be difficult to clean out and may damage the system.
VI. When to shut down the system.
Shut down the system at the end of the work shift and before checking, adjusting, cleaning or repairing the system. Always follow the Pressure relief procedure on page 8.
This system has a maximum air working pressure of 100 psi (6.9 bar) which produces a maximum fluid working pressure of 3000 psi (210 bar). Higher pressure can cause the system to rupture or mal- function and result in serious injury.

I. When to flush.
Before the first time use
When changing colors
Before fluid can dry or settle out in a dormant sys- tem (observe the recommended fluid pot life on cat- alyzed fluids)
Before storing the system
II. How to flush. See Fig. 6.

A Bleed-type master air valve 3 Air-assisted airless spray gun 5 Fluid filter 8a Pump air regulator 8b Gun air regulator 14 Bleed–type air valve 26 Filter drain valve


Model 237–421, Series A Includes items 1 to 34
Ref No. Part No. Description Qty
Ref No. Part No. Description Qty
1 223–843 PRESIDENT PUMP See 308–106 for parts 1 2 224–044 CART, portable See 308–136 for parts 1 3 223–283 AIR ASSISTED AIRLESS SPRAY GUN See 308–176 for parts 1 4 182–411 SPRAY TIP, 0.011 orifice, 8–10” (203–254 mm) fan width 1 5 223–160 FLUID FILTER See 307–273 for parts 1 6 236–074 FLUID HOSE, cpld 1/4 npt (fbe) 3/16” ID x 25’ (4.8 mm ID x 7.6 m) 1 7 210–867 AIR HOSE, cpld 1/4 npsm (fbe) 1/4” ID x 25’ (6.3 mm ID x 7.6 m) 1 8 104–267 AIR REGULATOR 0–125 psi (0–9 bar) range See 308–167 for parts 2 9 101–180 AIR PRESSURE GAUGE 0–200 psi (0–14 bar) 2 10 155–470 90 SWIVEL ADAPTER UNION, 1/2 npt(m) x 1/2 npsm(f) swivel 2 11 218–093 AIR HOSE, buna-S, cpld 1/2 npt(mbe), 1/2” ID x 22” (13 mm ID x 559 mm) 1 12 222–297 45 SWIVEL ADAPTER UNION, 1/2 npt(m) x 1/2 npsm(f) swivel 1 13 158–491 NIPPLE, 1/2 npt, 1.625” (41 mm) long 1 14 107–142 BLEED–TYPE AIR VALVE, 1/2 npt (f) 1
15 112–941 FLUID PRESSURE GAUGE 1 16 166–999 ELBOW, reducing street, 1/2 npt(m) x 1/4 npt(f) 1 17 162–453 NIPPLE, 1/4 npt x 1/4 npsm 1 18 236–075 SUCTION HOSE, 3/4 npt(mbe), 3/4” ID x 3.5’ (19 mm ID x 1.1 m) 1 19 112–191 SUCTION TUBE, 3/4 npt(f) 1 20 112–192 FLUID INTAKE ELBOW, 3/4 npt(f), 1 21 100–016 LOCKWASHER, 1/4” spring 2 22 100–270 CAPSCREW, hex hd, 1/4–20 x 5/8” (16 mm) long 2 23 235–208 SWIVEL UNION, 3/8 npt(m) x 3/8 npsm(f) 1 24 206–994 THROAT SEAL LIQUID, 8 oz. 1 25 188–089 NIPPLE, 3/8 npt x 3/8–18.6 sf 1 26 235–992 BALL VALVE, 3/8 npt x 1/4 npt (mbe) see 306–861 for parts 1 27 156–877 NIPPLE, 1/2 npt, 2.5” (63.5 mm) 2 28 188–595 PUMP MOUNTING PLATE 1 29 102–254 SCREW, hex hd, 1/4–20 x 7/8” (22 mm) long 2 30 237–569 GROUND WIRE and CLAMP 12 gauge (1.5 mm2), 25’ (7.6 m) 1 33 100–509 PLUG, 1/4 npt sq hd pipe 2 34 179–749 AIR MANIFOLD, 1/2 npt inlet, two 1/2 npt outlets 1 35 157–416 90 SWIVEL UNION 1 36 150–286 ADAPTER 1


Model 237–421, Series A Includes items 1 to 34



Maximum Fluid Working Pressure 3000 psi (210 bar) Maximum Air Operating Pressure 100 psi (6.9 bar) Pump Air Consumption free flow: 20 scfm at 100 psi (0.56 m3/min at 6.9 bar) . . . Gun Air Consumption 5 scfm at 30 psi (0.14 m3/min at 2.1 bar) Wetted Parts
Pump 304/316/420/17–pH stainless steel, chrome plating,
tungsten carbide, PTFE, leather, UHMWPE Gun 303 stainless steel, carbide, UHMWPE CV75,
polyethylene, PTFE, Delrin Fluid filter 303/304/316 stainless steel, polyethylene, PTFE Fluid fittings 304/316 stainless steel Fluid hose nylon
Graco warrants all equipment manufactured by it and bearing its name to be free from defects in fluid and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. As purchaser’s sole remedy for breach of this warranty, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment proven defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for, any malfunction, damage or wear caused by faulty installation, misap- plication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility with Graco equipment of structures, accessories, equipment or fluids not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or fluids not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claim. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in fluid or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor and transportation.
The terms of this warranty constitute purchaser’s sole and exclusive remedy and are in lieu of any other warranties (express or implied), including warranty of merchantability or warranty of fitness for a particular purpose, and of any non–contractual liabili- ties, including product liabilities, based on negligence or strict liability. Every form of liability for direct, special or consequential damages or loss is expressly excluded and denied. In no case shall Graco’s liability exceed the amount of the purchase price. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose, with respect to accessories, equipment, fluids, or components sold but not manufactured by Graco. These items sold, but not manufac- tured by Graco (such as electric motor, switches, hose, etc.) are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
TO PLACE AN ORDER, contact your Graco distrib- utor, or call this number to identify the distributor closest to you: 1–800–367–4023 Toll Free
FOR TECHNICAL ASSISTANCE, service repair information or assistance regarding the application of Graco equipment: 1–800–543–0339 Toll Free
Sales Offices: Atlanta, Chicago, Dallas, Detroit, Los Angeles, Mt. Arlington (N.J.) Foreign Offices: Canada, England, Korea, Switzerland, France, Germany, Hong Kong, Japan
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 PRINTED IN U.S.A. 308–460 9/94
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.