Page 1 of the Graco 230992 user manual — With drum cover and agitator
Page 1 · click to enlarge
Page 1

Instructions – Parts List

Parts

55 GALLON SUPPLY PUMPS 3:1 President, 4:1 President, and 2:1 Monark

Graco 230992 — Parts diagram (page 1)
Fig. 1 · Parts

307745G

With drum cover and agitator

Model 220575, Series B with 3:1 Ratio President Pump 500 psi (3.5 MPa, 35 bar) MAXIMUM FLUID WORKING PRESSURE

∗ Model 230992, Series C with 4:1 Ratio President Pump 400 psi (2.8 MPa, 28 bar) MAXIMUM FLUID WORKING PRESSURE

Model 230993, Series C with 2:1 Ratio Monark Pump 200 psi (1.4 MPa, 14.0 bar) MAXIMUM FLUID WORKING PRESSURE

Read warnings and instructions. See page 2 for table of contents.

04281A Model 230992 Shown

Page 3 of the Graco 230992 user manual — MOVING PARTS HAZARD
Page 3 · click to enlarge
Page 3

MOVING PARTS HAZARD

The air motor piston can pinch or amputate your fingers.

The rotating blades of the agitator can pinch or amputate your fingers or other body parts and can cause splashing in the eyes or on the skin.

Always shut off the agitator and disconnect the air line before adjusting the angle of the agitator, removing the agitator from the drum, or checking or repairing any part of the agitator.

Keep clear of all moving parts when starting or operating the equipment.

Before servicing the equipment, follow the Pressure Relief Procedure on page 7 to prevent the equipment from starting unexpectedly.

307745 3

Page 4 of the Graco 230992 user manual — TOXIC FLUID HAZARD
Page 4 · click to enlarge
Page 4

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. Ground the equipment and the object being sprayed. Refer to Grounding on page 5.

If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately. Do not use the equipment until you identify and correct the problem.

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed.

Keep the spray area free of debris, including solvent, rags, and gasoline.

Electrically disconnect all equipment in the spray area.

Extinguish all open flames or pilot lights in the spray area.

Do not smoke in the spray area.

Do not turn on or off any light switches in the spray area while operating or if fumes are present.

Do not operate a gasoline engine in the spray area.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

Always wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid and solvent manufacturer.

4 307745

Page 5 of the Graco 230992 user manual — Grounding
Page 5 · click to enlarge
Page 5

Setup

Object being sprayed: Follow your local code. Fluid supply container: Follow your local code. Solvent pails used when flushing: Follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or card- board, which interrupts the grounding continuity. To maintain proper grounding continuity when flushing or relieving pressure, always hold the metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun. Positioning the Unit

Accessories are available from your Graco repre- sentative. If you supply your own accessories, be sure they are adequately sized and pressure-rated to meet the system’s requirements.

Grounding

FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 4.

Select a convenient location for the unit. The air valves for the pump (37) and agitator (5) must be fully accessible. System Accessories

Proper grounding is an essential part of maintaining a safe system. To reduce the risk of static sparking, the mounting cover and all electrically conductive objects or devices in the spray area must be properly grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Agitator and drum cover: Connect one end of the ground wire (Y) to the ground connector (X) on the rim of the drum cover. See Fig. 1. Connect the other end of the ground wire to a true earth ground. See the pump instruction manual (307986 for 230992, 307985 for model 230993, or 308793 for model 220575) for instructions on grounding the pump.

A bleed-type master air valve (N) and a fluid drain valve (K) are required in your system. These accessories help reduce the risk of serious injury, including splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjust- ing or repairing the pump or agitator. The bleed-type master air valve relieves air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpectedly. Locate the valve close to the pump. A red–handled bleed–type ball valve is supplied to relieve air trapped in the air motor. The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient. Order Part No. 210071.

Y Fig. 1

Air and fluid hoses: Use only electrically conductive hoses with 500 ft. (150 m) maximum combined hose length to ensure grounding continuity. Air compressor: Follow manufacturer’s recommenda- tions. Spray gun or dispensing valve: Ground through con- nection to a properly grounded fluid hose and pump.

307745 5

Page 6 of the Graco 230992 user manual — 04283A
Page 6 · click to enlarge
Page 6

Setup

The installation shown in Fig. 2 is only a guide for selecting and installing system components and accessories. Contact your Graco representative for assistance in designing a system to suit your particular needs. Connecting the Unit and Accessories

The fluid line must include a fluid drain valve (K), which helps relieve fluid pressure in the hose and gun.

Ground the unit as described in Grounding on page 5.

You should install an air line filter (J) to remove dirt and moisture from the air supply.

The main air supply must include a bleed-type master air valve (N) for shutting off air pressure to the unit (supplied with Model 230992).

Downstream from the air filter, you should install an air line lubricator (H) for automatic air motor lubrica- tion.

Connect a grounded air supply hose to the bleed type pump air valve (N).

Graco 230992 — Setup diagram (page 6)
Fig. 2 · Setup

Y

KEY

A Air Filter/Regulator to Gun B Fluid Pressure Regulator C Fluid Shutoff Valve D Fluid Filter E Surge Tank F Bleed–type Master Air Valve G Pump Ground Wire

H Air Line Lubricator J Air Filter to Pump K Drain Valve L Air Spray Circulating Gun M Back Pressure Valve (same as 203 except customer supplied) N Bleed–type Pump Air Valve

Y Drum Cover/Agitator Ground Wire 3 Agitator 201 Air Supply Hose 203 Back Pressure Valve 204 Air Regulator 206a Return Fluid Hose 206b Supply Fluid Hose

04283A

6 307745

Page 7 of the Graco 230992 user manual — CAUTION
Page 7 · click to enlarge
Page 7

Operation

Pressure Relief Procedure

Flush the pump before first use. The pump is tested with lightweight oil, which is left in to protect the pump parts. If the fluid you are using may be contami- nated by the oil, flush it out with a compatible solvent.

PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally. To reduce the risk of an injury from acci- dental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Proce- dure whenever you:

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.

are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray nozzle.

To clean any settled particles out of the system, flush the entire system at least once each 90 days or less. If possible, circulate the solvent and leave it in the lines for two days, such as over the weekend, to help loosen any dried paint. 1. Relieve the pressure.

1. Lock the gun trigger safety.
2. Shut off the air supply to the pump.
2. Shutdown the system as explained in Shutdown and Care of the Pump on page 9.
3. Close the bleed-type master air valve (required in your system). On Model 230992, this is the red– handled ball valve, assembled next to the air regulator.
3. Start the pump and operate it at about 30 cycles per minute.
4. Unlock the gun trigger safety.
4. Lubricate the agitator, if you haven’t already done so, and then close its air valve to stop agitation.
5. Hold a metal part of the gun firmly to the side of a grounded metal pail, and trigger the gun to relieve pressure.
6. Lock the gun trigger safety.

Failure to shut off the agitator before raising the pump assembly may result in serious injury from splashing paint in the eyes or contact with the blades of the agitator.

7. Open the drain valve (required in your system), and have a container ready to catch the drainage.
8. Leave the drain valve open until you are ready to spray again.
5. Raise the pump out of the paint while it is still running and let it run itself dry to force the paint back into the drum. Shut off the pump.

If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve the pressure gradually. Then loosen it completely. Then clear the tip or hose. Flushing

CAUTION

Never leave water or water-based fluid in the pump overnight. Flush with a compatible solvent to protect the parts from corrosion.

6. Remove the paint drum and place a 55 gallon drum, containing enough solvent to thoroughly fill and flush the system, under the pump. Lower the pump.

FIRE AND EXPLOSION HAZARD Before flushing, read the section FIRE AND EXPLOSION HAZARD on page 4. Be sure the entire system and flushing pails are properly grounded. Refer to Grounding on page 5.

7. Start the pump again and allow the solvent to circulate for at least one hour.

307745 7

Page 8 of the Graco 230992 user manual — Starting and Adjusting the Pump
Page 8 · click to enlarge
Page 8

Operation

8. Shut off the air to the pump, open the bleed–type master air valve, and open the drain valve (K). Leave the solvent in the system overnight or, if possible, all weekend.
5. When the paint returns through the return line in a steady stream, turn on the air to one gun, open both fluid shutoff valves (C) near the gun, and adjust the fluid regulator (B). See the manuals supplied with these components for pressure range and adjustment . Repeat for all gun stations.
9. Start the pump and circulate it again for 30 minutes. Raise the pump out of the solvent and let it dry to force out the solvent. Drain solvent from all outlet loops and filters.
6. Paint line pressure is controlled by the back pressure regulator (203). This regulator restricts flow of paint in the line so there is sufficient paint pressure at all gun stations. Turn the regulator handle clockwise to increase and counter–clockwise to decrease pressure. Adjust the regulator so there is about 10 psi (0.6 bar) more fluid pressure at the regulator than is required at the last gun in the line.
10. Place the paint supply drum under the pump, agitate the paint, install the gun and hoses.
11. Reset the air and fluid pressure regulators to complete the system flushing.

Adjusting the Unit

Install supply drum under cover/pump. Make sure that the cover is supported by the drum.

NOTE: As you increase fluid line pressure, you must also increase air pressure to the pump, so the pump can handle the heavier load. However, never increase the pressure so much that you exceed the maximum working pressure of any component in the system. 7. As you start to spray, adjust the air and fluid pressures to the gun to obtain the best results.

CAUTION

Shortened or recycled drums may cause the pump or agitator to bottom out in the drum, causing damage. Contact your fluid supplier to order a standard size drum.

CAUTION

1. Unscrew the filter bowl and remove the filter screen. Replace the bowl. Flush the unit until clear solvent comes from the gun, then reinstall the filter screen.

Do not allow the pump to run dry. It will quickly accelerate to a high speed, causing damage. If your pump is running too fast, stop it immediately and check the fluid supply. If the container is empty and air has been pumped into the lines, refill the container and prime the pump and the lines, or flush and leave it filled with a compatible solvent. Eliminate all air from the fluid system.

2. Before operation, ensure that all fasteners and tube connections are tightened securely.

Starting and Adjusting the Pump

1. Close the air regulator (204).
2. Start the agitator (3). Agitate the paint just fast enough to keep all paint particles suspended. Over–agitating causes air bubbles in the paint which can cause poor gun performance and poor surface finish.

COMPONENT RUPTURE HAZARD To reduce the risk of overpressurizing your system, which could cause compo- nent rupture and serious injury, never exceed the specified Maximum Incoming Air Pres- sure to the pump. (see Technical Data on page 15.)

3. Open the red–handled ball valve. Open the pump’s bleed-type master air valve (N).
4. Slowly open the air regulator until the pump starts. Adjust it until the pump cycles slowly – about 50 cycles per minute.

8 307745

Page 9 of the Graco 230992 user manual — Shutdown and Care of the Pump
Page 9 · click to enlarge
Page 9

Operation

Shutdown and Care of the Pump

4. Open the bleed–type master air valve (N), and the pump air regulator (204) to restart the pump. Circulate the paint to remove all trapped air before shutting down.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.

5. Disconnect the gun’s fluid hose from the gun and the fluid regulator. Plug the regulator outlet. Blow compressed air and compatible solvent through the hose to clean it. Clean the gun according to the instructions supplied with it. Each month remove and clean the fluid regulator.

Never allow paint to dry in the pump and lines.

To shutdown the system 1. Relieve the pressure. Stop the agitator, and lubricate it.

6. If you are not using an air line lubricator, manually lubricate the motor at least once a day.
2. If using a Graco fluid pressure regulator at the gun, reverse its regulating key and thread it into the regulator cap as far as it will go.
3. Loosen the spray gun air cap about three turns, hold a rag over the front of the air cap and fully trigger the gun. This forces paint in the gun, hose and regulator back into the circulating line. Close the fluid shutoff valves (C) at that gun station, Repeat for the other gun stations.
7. Circulate the fluid in the lines often enough during the shutdown to prevent the paint from drying.

307745 9

Page 10 of the Graco 230992 user manual — (MONARK PUMP SHOWN)
Page 10 · click to enlarge
Page 10

Parts Drawing

Model 230992, Series B 4:1 Ratio President Carbon Steel 55 Gallon Drum System Includes items 1 to 4, and 6 to 12

Model 230993, Series B 2:1 Ratio Monark Carbon Steel 55 Gallon Drum System Includes items 2 to 6, and 11

(MONARK PUMP SHOWN)

c Fig. 3

1 or 5 · 10 307745

Page 11 of the Graco 230992 user manual — Parts List
Page 11 · click to enlarge
Page 11

Parts List

Model 230992, Series B 4:1 Ratio President Carbon Steel 55 Gallon Drum System Includes items 1 to 4, and 6 to 12

Model 230993, Series B 2:1 Ratio Monark Carbon Steel 55 Gallon Drum System Includes items 2 to 6, and 11 Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

1 223183 4:1 RATIO PRESIDENT PUMP; See 307986 for parts. 1 2 237307 COVER, drum; See 308466 for parts. 1 3 203711 AGITATOR; See 306459 for parts. 1 5 223185 2:1 RATIO MONARK PUMP; See 307985 for parts 1 6 237569 GROUND WIRE AND CLAMP 1

7 160032 NIPPLE; 3/4 npt x 2 1 8 158491 NIPPLE; 1/2 npt x 2 1 9 113331 BALL VALVE, air, bleed-type 1 10 156684 UNION, adapter, swivel; 1/2” npt(m) x 1/2 npt(f) 1 11 158491 FITTING, nipple(used on 230992) 1 159239 FITTING, nipple(used on 230993) 1 12 162505 UNION, swivel 1

307745 11

Page 12 of the Graco 230992 user manual — 7679A
Page 12 · click to enlarge
Page 12

Parts Drawing

Model 220575, Series B 3:1 Ratio President Stainless Steel 55 Gallon Drum System Includes items 1–35

Remove and discard 1/2 x 3/8 npt nipple from outlet of air regulator (5a), and replace with 1/2 npt nipple (5c). Then connect air regulator assy to pump air inlet.

Agitator (3) is tilted at a 6 angle.

Ref No. 5 includes items 5a–5c.

3 REF

1 REF

3 REF

Ref No. 6 includes items 6a–6d.

7679A

Show 5 more labels / short text on this page
5a · 6d · 6b,6c · 6a · 12 307745
Page 13 of the Graco 230992 user manual — Parts List
Page 13 · click to enlarge
Page 13

Parts List

Model 220575, Series B 3:1 Ratio President Stainless Steel 55 Gallon Drum System

Ref Part No. No. Description Qty

6 223319 RETURN TUBE KIT Includes items 6a–6d 1 Ref Part No. No. Description Qty

1 220564 PUMP, President See 308793 for parts 1 2 237309 COVER, drum, 55 gal. (200 liter) See 308466 for parts 1 3 222698 AGITATOR See 306840 for parts 1 4 220580 RISER TUBE KIT See 307837 for parts 1 5 223180 AIR REGULATOR KIT Includes items 5a–5c 1 5a 203716 REGULATOR, air See 308167 for parts 1 5b 205418 HOSE, air; buna-N; 1/2” ID; coupled 1/2 npt (mbe); 6 ft (1.9 m) lg 1 5c 158491 NIPPLE; 1/2 npt 1

6a 185393 TUBE, return; sst; 1” npt(m) 1 6b 178941 NUT, hex; 1–5/8–18 unef–2b 1 6c 185394 ADAPTER, return; 1–5/8–18 unef–2a(m) x 1” npt(f) x 1” npt(f) 1 6d 108761 ELBOW, street; 1” npt (m x f) 1 7 185466 NIPPLE, half; 1–1/2” npt 1 17 190192 GASKET, agitator, guide 1 18 112896 SCREW, cap, hex hd 4 19 104123 WASHER, lock, spring 4 20 174092 PLATE, adapter 1 22 112894 SCREW, cap, hex hd 3 23 112904 WASHER, lock, 5/16 in. 3 35 100839 ELBOW, 1/8 npt (m x f) 1

307745 13

Page 14 of the Graco 230992 user manual — Notes
Page 14 · click to enlarge
Page 14

Notes

14 307745

Page 15 of the Graco 230992 user manual — Technical Data
Page 15 · click to enlarge
Page 15

Technical Data

Category Model 220575 Model 230992 Model 230993

Ratio 3:1 4:1 2:1

Maximum fluid working pressure

500 psi (3.5 MPa, 35 bar) 400 psi (2.8 MPa, 28 bar) 200 psi (1.4 MPa, 14 bar)

Maximum air input pressure

166 psi (1.2 MPa, 11.6 bar)

100 psi (0.7 MPa, 7 bar) 100 psi (0.7 MPa, 7 bar)

Pump cycles per 1 gallon (3.8 liters)

6.3 8 11

Fluid flow at 60 cycles per minute

9.2 gpm (35.1 liters/min) 8 gpm (30.4 liters/min) 5.5 gpm (21 liters/min)

Fluid inlet size 1–1/2 npt(f) 1–1/2 npt(f) 1–1/2 npt(f)

Fluid outlet size 1 in. npt(f) 1 in. npt(f) 1 in. npt(f)

Air inlet size 1/2 npt(f) 3/8 npt(f) 3/8 npsm(f)

Weight 110 lb (50 kg) 110 lb (50 kg) 110 lb (50 kg)

Maximum pump operating temperature

180F (82C) 180F (82C) 180F (82C)

* Sound pressure levels (dBa) (Input air pressures at 15 cycles per minute)

73.6 dB(A) @ 40psi (0.3 MPa, 2.8 bar) 78.3 dB(A) @ 70 psi (0.5 MPa, 4.8 bar) 80.9 dB(A) @100 psi (0.7 MPa, 7 bar)

73.6 dB(A) @ 40 psi (0.3 MPa, 2.8 bar) 78.3 dB(A) @ 70 psi (0.5 MPa, 4.8 bar) 80.9 dB(A) @100 psi (0.7 MPa, 7 bar)

73.3 dB(A) @ 40 psi (0.3 MPa, 2.8 bar) 75.9 dB(A) @ 70 psi (0.5 MPa, 4.8 bar) 77.7 dB(A) @100 psi (0.7 MPa, 7 bar)

* Sound power levels (dBa) (Input air pressures at 15 cycles per minute)

87.4 dB(A) @ 40 psi (0.3 MPa, 2.8 bar) 92.1 dB(A) @ 70 psi (0.5 MPa, 4.8 bar) 94.6 dB(A) @100 psi (0.7 MPa, 7 bar)

87.4 dB(A) @ 40 psi (0.3 MPa, 2.8 bar) 92.1 dB(A) @ 70 psi (0.5 MPa, 4.8 bar) 94.6 dB(A) @100 psi (0.7 MPa, 7 bar)

87.0 dB(A) @ 40 psi (0.28 MPa, 2.8 bar) 89.7 dB(A) @ 70 psi (0.5 MPa, 4.8 bar) 91.4 dB(A) @100 psi (0.7 MPa, 7 bar)

Wetted parts Chrome Plated Stainless Steel, Ultra–High Molecular Weight Polyethylene, Leather, PTFE

Supply and Return TubesNickel-plated carbon steel Air Motor Base: Aluminum Displacement Pump: Refer to manual 307983

* Tested in accordance with ISO 9614–2.

307745 15

Page 16 of the Graco 230992 user manual — Graco Information
Page 16 · click to enlarge
Page 16

Graco Standard Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Graco Information

TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers

to identify the distributor closest to you:

1–800–328–0211 Toll Free 612–623–6921 612–378–3505 Fax

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Sales OfficeMinneapolis International Offices: Belgium, Korea, Hong Kong, Japan

www.graco.com PRINTED IN USA 307745 05/1986, Revised 04/2004

16 307745

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Graco 230992

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 230992

Be the first to ask — other owners or our team will answer.

Original document

Graco 230992 manual PDF

16 pages·1.1 MB·Water Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…