Instruction/ maintenance manual of the product 223185 Series C Graco
Go to page of 18
Instructions – Parts List GRACO INC. P .O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 1989, Graco Inc. is registered to I.S. EN ISO 9001 2:1 Ratio Monark R Pump 200 psi (1.4 MPa, 14 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure Part No.
2 307985 Symbols W arning Symbol W ARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
307985 3 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
4 307985 Notes.
307985 5 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor .
6 307985 Installation 06089 Fig. 2 KEY A Bleed-T ype Master Air V alve (required, for pump) B Air Filter/Regulator C Air Line Lubricator D Fluid Drain V alve (required) E Surge T a nk F Fluid Shutoff .
307985 7 Installation A vailable Accessories (must be purchased separately) Air Line Accessories W ARNING A bleed-type master air valve (A) is required in your system to help reduce the risk of serious injury , including splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjust- ing or repairing the pump.
8 307985 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally .
307985 9 Operation Prime the Pump 1. See Fig. 2. Remove the spray nozzle from the gun. See the gun instruction manual. 2. Close all bleed-type air valves (A, N). 3. Close the pump air filter/regulator (B). 4. Close the fluid drain valve (D). 5. Check that all fittings throughout the system are tightened securely .
10 307985 Notes.
307985 1 1 Maintenance Shutdown and Care of the Pump W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
12 307985 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Relieve the pressure. 2. Check all possible problems and solutions before disassembling pump.
307985 13 Service Disconnecting the Displacement Pump NOTE: For displacement pump repair instructions, refer to the separate displacement pump manual 307983, supplied. W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
14 307985 Parts Model 223185, Series C 2:1 Ratio Monark Pump, 55 Gallon (200 Liter) Drum Size; UHMWPE and Leather Packed Ref Part No. No. Description Qty 1 206955 AIR MOTOR, Monark See 307043 for parts 1 3 223177 PUMP , displacement; used on Model 223185 See 307983 for parts 1 4 19161 1 ROD, connecting; 19.
307985 15 Parts Model 223186, Series C 2:1 Ratio Monark Pump, Stubby Size; UHMWPE and Leather Packed Ref Part No. No. Description Qty 1 206955 AIR MOTOR, Monark See 307043 for parts 1 3 223177 PUMP , displacement; used on Model 223186 See 307983 for parts 1 4 191736 ROD, connecting; 6.
16 307985 Dimensions 06085 A B C Model No. A B C 223185 47.81 in. (1215 mm) 15.31 in. (389 mm) 32.5 in. (826 mm) 223186 35.31 in. (897 mm) 15.31 in. (389 mm) 20 in. (508 mm) Mounting Hole Layout 2.254 in. (57.25 mm) 5.250 in. (133.4 mm) 0.375 in. (9.52 mm) diameter 2.
307985 17 T echnical Data Category Data Ratio 2:1 Maximum fluid working pressure 200 psi (14 bar) Maximum air input pressure 100 psi (7 bar) Pump cycles per 1 gallon (3.8 liters) 11 Fluid flow at 60 cycles per minute 5.5 gpm (21 liters/min) Fluid inlet size 1–1/2 npt(f) Fluid outlet size 1 in.
18 307985 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
An important point after buying a device Graco 223185 Series C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco 223185 Series C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco 223185 Series C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco 223185 Series C you will learn all the available features of the product, as well as information on its operation. The information that you get Graco 223185 Series C will certainly help you make a decision on the purchase.
If you already are a holder of Graco 223185 Series C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco 223185 Series C.
However, one of the most important roles played by the user manual is to help in solving problems with Graco 223185 Series C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco 223185 Series C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center