EN
Graco logo
Official user manual

Graco 17C305

41 pages·12 MB·Paint Sprayer·PDF·ENDEFRITNLJA
Graco 17C305
Table of Contents 30 sections Warnings · Component Identification · Stand Model · Hi-Boy Models · … ShowHide
Page 1 of the Graco 17C305 user manual — Related Manuals Gun – 312830 (SG3) Pump – 334599
Page 1 · click to enlarge
Page 1

Operation, Parts

210 ES Electric Airless Sprayers

EN

For professional use only. Not approved for use in explosive atmospheres or hazardous locations. For portable airless spraying of architectural paints and coatings.

Models: 17D163, 17C305

3000 psi (207 bar, 20.7 MPa) Maximum Working Pressure

Related Manuals Gun – 312830 (SG3) Pump – 334599

Graco 17C305 — Related Manuals Gun – 312830 (SG3) Pump – 334599 diagram (page 1)
Fig. 1 · Related Manuals Gun – 312830 (SG3) Pump – 334599

Use only genuine Graco replacement parts. The use of non-Graco replacement parts may void warranty.

Page 3 of the Graco 17C305 user manual — 120V US
Page 3 · click to enlarge
Page 3

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

GROUNDING

  • This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
  • Improper installation of the grounding plug is able to result in a risk of electric shock.
  • When repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal.
  • The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.
  • Check with a qualified electrician or serviceman when the grounding instructions are not completely understood, or when in doubt as to whether the product is properly grounded.
  • Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qualified electrician.
  • This product is for use on a nominal 120V circuit and has a grounding plug similar to the plugs illustrated below.

120V US

  • Only connect the product to an outlet having the same configuration as the plug.
  • Do not use an adapter with this product. Extension Cords:
  • Use only a 3-wire extension cord that has a grounding plug and a grounding receptacle that accepts the plug on the product.
  • Make sure your extension cord is not damaged. If an extension cord is necessary use 12 AWG (2.5mm 2 ) minimum to carry the current that the product draws.
  • An undersized cord results in a drop in line voltage and loss of power and overheating.
Page 4 of the Graco 17C305 user manual — FIRE AND EXPLOSION HAZARD
Page 4 · click to enlarge
Page 4

Warnings

FIRE AND EXPLOSION HAZARD

  • Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
  • Do not spray flammable or combustible materials near an open flame or sources of ignition such as cigarettes, motors, and electrical equipment.
  • Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity creates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of the spray system, including the pump, hose assembly, spray gun, and objects in and around the spray area shall be properly grounded to protect against static discharge and sparks. Use Graco conductive or grounded high-pressure airless paint sprayer hoses.
  • Verify that all containers and collection systems are grounded to prevent static discharge. Do not use pail liners unless they are antistatic or conductive.
  • Connect to a grounded outlet and use grounded extensions cords. Do not use a 3-to-2 adapter.
  • Do not use a paint or a solvent containing halogenated hydrocarbons.
  • Do not spray flammable or combustible liquids in a confined area.
  • Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.
  • Sprayer generates sparks. Keep pump assembly in a well ventilated area at least 20 feet (6.1 m) from the spray area when spraying, flushing, cleaning, or servicing. Do not spray pump assembly.
  • Do not smoke in the spray area or spray where sparks or flame is present.
  • Do not operate light switches, engines, or similar spark producing products in the spray area.
  • Keep area clean and free of paint or solvent containers, rags, and other flammable materials.
  • Know the contents of the paints and solvents being sprayed. Read all Material Safety Data Sheets (MSDS) and container labels provided with the paints and solvents. Follow the paint and solvents manufacturer’s safety instructions.
  • Fire extinguisher equipment shall be present and working.
Page 5 of the Graco 17C305 user manual — SKIN INJECTION HAZARD
Page 5 · click to enlarge
Page 5

Warnings

SKIN INJECTION HAZARD

  • High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection occurs, get immediate surgical treatment.
  • Do not aim the gun at, or spray any person or animal.
  • Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.
  • Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.
  • Use Graco nozzle tips.
  • Use caution when cleaning and changing nozzle tips. In the case where the nozzle tip clogs while spraying, follow the Pressure Relief Procedure for turning off the unit and relieving the pressure before removing the nozzle tip to clean.
  • Equipment maintains pressure after power is shut off. Do not leave the equipment energized or under pressure while unattended. Follow the Pressure Relief Procedure when the equipment is unattended or not in use, and before servicing, cleaning, or removing parts.
  • Check hoses and parts for signs of damage. Replace any damaged hoses or parts.
  • This system is capable of producing 3000 psi. Use Graco replacement parts or accessories that are rated a minimum of 3000 psi.
  • Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.
  • Verify that all connections are secure before operating the unit.
  • Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls. EQUIPMENT MISUSE HAZARD
  • Misuse can cause death or serious injury.
  • Always wear appropriate gloves, eye protection, and a respirator or mask when painting.
  • Do not operate or spray near children. Keep children away from equipment at all times.
  • Do not overreach or stand on an unstable support. Keep effective footing and balance at all times.
  • Stay alert and watch what you are doing.
  • Do not operate the unit when fatigued or under the influence of drugs or alcohol.
  • Do not kink or over-bend the hose.
  • Do not expose the hose to temperatures or to pressures in excess of those specified by Graco.
  • Do not use the hose as a strength member to pull or lift the equipment.
  • Do not spray with a hose shorter than 25 feet.
  • Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards.
  • Make sure all equipment is rated and approved for the environment in which you are using it.
Page 6 of the Graco 17C305 user manual — ELECTRIC SHOCK HAZARD
Page 6 · click to enlarge
Page 6

Warnings

ELECTRIC SHOCK HAZARD

  • This equipment must be grounded . Improper grounding, setup, or usage of the system can cause electric shock.
  • Turn off and disconnect power cord before servicing equipment.
  • Connect only to grounded electrical outlets.
  • Use only 3-wire extension cords.
  • Ensure ground prongs are intact on power and extension cords.
  • Do not expose to rain. Store indoors. PRESSURIZED ALUMINUM PARTS HAZARD
  • Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.
  • Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents.
  • Do not use chlorine bleach.
  • Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for compatibility. MOVING PARTS HAZARD
  • Moving parts can pinch, cut, or amputate fingers and other body parts.
  • Keep clear of moving parts.
  • Do not operate equipment with protective guards or covers removed.
  • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure and disconnect all power sources. TOXIC FLUID OR FUMES HAZARD
  • Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
  • Read MSDSs to know the specific hazards of the fluids you are using.
  • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. PERSONAL PROTECTIVE EQUIPMENT
  • Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is not limited to:
  • Protective eyewear, and hearing protection.
  • Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer. CALIFORNIA PROPOSITION 65

This product contains a chemical known to the State of California to cause cancer, birth defects or other reproductive harm. Wash hands after handling.

Page 7 of the Graco 17C305 user manual — Component Identification
Page 7 · click to enlarge
Page 7

Component Identification

Component Identification

Stand Model

Graco 17C305 — Component Identification diagram (page 7)
Fig. 2 · Component Identification

A ON/OFF Switch B Pressure Control D Prime Valve F Tip Guard G Spray Tip H Gun J Airless Hose K Power Cord L Trigger Lock

M Drain Tube N Fluid Intake P Pump R Fluid Outlet S Power Cord Wrap U Filter V Finger Guard / TSL Fill Point Model/Serial Tag (Not shown, located on bottom of unit.)

Page 8 of the Graco 17C305 user manual — Component Identification
Page 8 · click to enlarge
Page 8

Component Identification

Hi-Boy Models

Graco 17C305 — Component Identification diagram (page 8)
Fig. 3 · Component Identification
AON/OFF Switch BPressure Control DPrime Valve FTip Guard GSpray Tip HGun JAirless Hose KPower Cord LTrigger Lock

M Drain Tube N Fluid Intake P Pump R Fluid Outlet S Hanger T Filter U Finger Guard / TSL Fill Point V Pail Hook Model/Serial Tag (Not shown, located on bottom of unit.)

Page 9 of the Graco 17C305 user manual — Pails
Page 9 · click to enlarge
Page 9

Grounding

Grounding

Graco 17C305 — Grounding diagram (page 9)
Fig. 4 · Grounding
Graco 17C305 — Grounding diagram (page 9)
Fig. 5 · Grounding

The equipment must be grounded to reduce the risk of static sparking and electric shock. An electric or static spark can cause fumes to ignite or explode. An improper ground can cause electric shock. A good ground provides an escape wire for the electric current.

Always ground a metal pail: connect a ground wire to the pail. Clamp one end to the pail and the other end to a true earth ground such as a water pipe.

This sprayer includes a ground wire with an appropriate ground contact.

The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Graco 17C305 — Grounding diagram (page 9)
Fig. 6 · Grounding

Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qualified electrician.

Power Requirements

110-120V units require 100-120 VAC, 50/60 Hz, 13A, 1 phase.

To maintain ground continuity when sprayer is flushed or pressure is relieved: hold metal part of spray gun firmly to the side of a grounded metal pail then trigger the gun.

Extension Cords

Use an extension cord with an undamaged ground contact. If an extension cord is necessary, use a 3-wire, 12 AWG (2.5 mm2) minimum.

Graco 17C305 — Extension Cords diagram (page 9)
Fig. 7 · Extension Cords

Pails

Solvent and oil-based fluids: follow local code. Use only conductive metal pails, placed on a grounded surface such as concrete.

Do not place pail on a non-conductive surface such as paper or cardboard which interrupts grounding continuity.

Page 10 of the Graco 17C305 user manual — Pressure Relief Procedure
Page 10 · click to enlarge
Page 10

Pressure Relief Procedure

Pressure Relief Procedure

3. Turn pressure control to lowest setting. Disengage trigger lock.

Follow the Pressure Relief Procedure whenever you see this symbol.

Graco 17C305 — Pressure Relief Procedure diagram (page 10)
Fig. 8 · Pressure Relief Procedure
Graco 17C305 — Pressure Relief Procedure diagram (page 10)
Fig. 9 · Pressure Relief Procedure

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashed fluid and moving parts, follow the Pressure Relief Procedure whenever sprayer is stopped and before sprayer is cleaned or checked, and before equipment is serviced.

4. Hold a metal part of the gun firmly to a grounded metal pail. Trigger the gun to relieve pressure.
1. Turn ON/OFF switch to OFF position. Wait 7 seconds for power to dissipate.
Graco 17C305 — Pressure Relief Procedure diagram (page 10)
Fig. 10 · Pressure Relief Procedure
Graco 17C305 — Pressure Relief Procedure diagram (page 10)
Fig. 11 · Pressure Relief Procedure
5. Engage trigger lock.
Page 11 of the Graco 17C305 user manual — Trigger Lock
Page 11 · click to enlarge
Page 11

Pressure Relief Procedure

6. Put drain tube in pail. Turn prime valve down. Leave prime valve in down (drain) position until you are ready to spray again.

a. VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually.

b. Loosen nut or coupling completely. c. Clear hose or tip obstruction.

Graco 17C305 — Pressure Relief Procedure diagram (page 11)
Fig. 12 · Pressure Relief Procedure

Trigger Lock

Always engage the trigger lock when sprayer is stopped to prevent the gun from being triggered accidentally by hand or if dropped or bumped.

Graco 17C305 — Trigger Lock diagram (page 11)
Fig. 13 · Trigger Lock
7. If you suspect the spray tip or hose is clogged or that pressure has not been fully relieved:
Page 12 of the Graco 17C305 user manual — Setup
Page 12 · click to enlarge
Page 12

Setup

Setup

2. Connect other end of hose to gun.
Graco 17C305 — Setup diagram (page 12)
Fig. 14 · Setup
Graco 17C305 — Setup diagram (page 12)
Fig. 15 · Setup

When unpacking sprayer for the first time or after long term storage perform setup procedure. When first setup is performed remove shipping plug from fluid outlet.

1. Connect Graco airless hose to fluid outlet. Use wrenches to tighten securely.
3. Use wrenches to tighten securely.
Graco 17C305 — Setup diagram (page 12)
Fig. 16 · Setup
4. Engage trigger lock.
Graco 17C305 — Setup diagram (page 12)
Fig. 17 · Setup
Page 13 of the Graco 17C305 user manual — Setup
Page 13 · click to enlarge
Page 13
Graco 17C305 — Setup diagram (page 13)
Fig. 18 · Setup
6. When unpacking sprayer for the first time remove packaging materials from inlet strainer. After long term storage check inlet strainer for clogs and debris.
7. Fill throat packing nut with TSL to prevent premature packing wear. Do this daily or each time you spray.
9. Plug power supply cord into a properly grounded electrical outlet.

a. Place the TSL bottle nozzle into the top center opening in the grill at the front of the sprayer.

Graco 17C305 — Setup diagram (page 13)
Fig. 19 · Setup

b. Squeeze bottle to dispense enough TSL to fill the space between the pump rod and packing nut seal.

Page 14 of the Graco 17C305 user manual — Setup
Page 14 · click to enlarge
Page 14

Setup

10. Turn prime valve down.
14. Increase pressure 1/2 turn to start motor. Allow fluid to flush through sprayer for one minute.
Graco 17C305 — Setup diagram (page 14)
Fig. 20 · Setup
15. Turn prime valve horizontal. Disengage trigger lock.
Graco 17C305 — Setup diagram (page 14)
Fig. 21 · Setup
16. Hold a metal part of the gun firmly to a grounded metal pail. Trigger gun and flush until clean.
19. After flushing storage fluid out of the sprayer empty pail. Replace fluid intake with drain tube in grounded metal pail partially filled with flushing fluid. Use water to flush water-based paint or mineral spirits to flush oil-based paint.
11. Place fluid intake with drain tube in grounded metal pail partially filled with flushing fluid. See Grounding , page 9.
Graco 17C305 — Setup diagram (page 14)
Fig. 22 · Setup
20. Turn ON/OFF switch to ON position.
21. Turn prime valve horizontal. Disengage trigger lock.
22. Hold a metal part of the gun firmly to a grounded metal pail. Trigger gun and flush for one minute.
23. Turn ON/OFF switch to OFF position.
24. Engage trigger lock.
25. Sprayer is now ready to start up and spray.
12. Turn pressure control to lowest setting.
13. Turn ON/OFF switch to ON position.
Page 15 of the Graco 17C305 user manual — Startup
Page 15 · click to enlarge
Page 15

Startup

Startup

5. Increase pressure 1/2 turn to start motor. Allow paint to circulate through sprayer until paint flows out the drain tube.
Graco 17C305 — Startup diagram (page 15)
Fig. 23 · Startup
Graco 17C305 — Startup diagram (page 15)
Fig. 24 · Startup
1. Perform Pressure Relief Procedure , page 10.
2. Turn pressure control to lowest pressure.
Graco 17C305 — Startup diagram (page 15)
Fig. 25 · Startup
6. Turn prime valve horizontal. Disengage trigger lock.
Graco 17C305 — Startup diagram (page 15)
Fig. 26 · Startup
4. Place fluid intake in paint pail. Place drain tube in waste pail.
Page 16 of the Graco 17C305 user manual — Startup
Page 16 · click to enlarge
Page 16

Startup

7. Hold gun against grounded metal waste pail. Trigger gun until paint appears.
Graco 17C305 — Startup diagram (page 16)
Fig. 27 · Startup
Graco 17C305 — Startup diagram (page 16)
Fig. 28 · Startup
10. Screw tip assembly onto gun and tighten. See Spray Tip Installation , page 17. For gun assembly instructions, see separate gun manual.
8. Move gun to paint pail and trigger for 20 seconds. Release trigger and allow sprayer to build pressure. Engage trigger lock.
Graco 17C305 — Startup diagram (page 16)
Fig. 29 · Startup

High-pressure spray is able to inject toxins into the body and cause serious bodily injury. Do not stop leaks with hand or rag.

9. Inspect for leaks. If leaks occur, perform Pressure Relief Procedure , page 10, then tighten all fittings and repeat Startup procedure. If there are no leaks continue with the next step.
Page 17 of the Graco 17C305 user manual — Operation
Page 17 · click to enlarge
Page 17

Operation

Operation

Spray Tip Installation

3. Screw assembly onto gun. Tighten.
Graco 17C305 — Operation diagram (page 17)
Fig. 30 · Operation
1. Perform Pressure Relief Procedure , page 10.
2. Use spray tip (A) to insert OneSeal ™ (B) into tip guard (C).
Graco 17C305 — Operation diagram (page 17)
Fig. 31 · Operation
1. Spray test pattern. Adjust pressure to eliminate heavy edges.
2. Insert Spray Tip.
Graco 17C305 — Operation diagram (page 17)
Fig. 32 · Operation
Page 18 of the Graco 17C305 user manual — Operation
Page 18 · click to enlarge
Page 18

Operation

Clear Tip Clog

2. Use smaller tip size if pressure adjustment cannot eliminate heavy edges.
3. Hold gun perpendicular, 10-12 in. (25-30 cm) from surface. Spray back and forth; overlap by 50%.
1. Release trigger. Engage trigger lock. Rotate Spray Tip. Disengage trigger lock. Trigger gun at waste area to clear clog.
Graco 17C305 — Operation diagram (page 18)
Fig. 33 · Operation
Graco 17C305 — Operation diagram (page 18)
Fig. 34 · Operation
2. Engage trigger lock. Return Spray Tip to original position. Disengage trigger lock and continue spraying.
4. Trigger gun after moving. Release trigger before stopping. For additional spraying information, see separate gun manual.
Page 19 of the Graco 17C305 user manual — Operation
Page 19 · click to enlarge
Page 19

Operation

Cleanup

Graco 17C305 — Operation diagram (page 19)
Fig. 35 · Operation
Graco 17C305 — Operation diagram (page 19)
Fig. 36 · Operation
1. Perform Pressure Relief Procedure , page 10.
2. Remove tip guard and Spray Tip. For additional information, see separate gun manual.
Graco 17C305 — Operation diagram (page 19)
Fig. 37 · Operation
4. Place fluid intake in flushing fluid. Use water for water base paint and mineral spirits for oil-based paint. Place drain tube in waste pail.
3. Remove fluid intake and drain tube from paint, wipe excess paint off outside.
Graco 17C305 — Operation diagram (page 19)
Fig. 38 · Operation
5. Turn prime valve horizontal.
Page 20 of the Graco 17C305 user manual — Operation
Page 20 · click to enlarge
Page 20

Operation

6. Increase pressure 1/2 turn to start motor. Hold gun against paint pail. Disengage trigger lock. Trigger gun and increase pressure until the pump runs steady and flushing fluid appears.
Graco 17C305 — Operation diagram (page 20)
Fig. 39 · Operation
Graco 17C305 — Operation diagram (page 20)
Fig. 40 · Operation
7. Stop triggering gun. Move gun to waste pail, hold gun against pail, trigger gun to thoroughly flush system.
8. While continuing to trigger gun, turn prime valve down. Then, release gun trigger. Allow flushing fluid to circulate until fluid comes out of drain tube clear.
Page 21 of the Graco 17C305 user manual — Operation
Page 21 · click to enlarge
Page 21

Operation

10. Turn prime valve horizontal. Trigger gun into flushing pail to purge fluid from hose.
Graco 17C305 — Operation diagram (page 21)
Fig. 41 · Operation
11. Engage trigger lock.
Graco 17C305 — Operation diagram (page 21)
Fig. 42 · Operation
14. If flushing with water, flush again with mineral spirits or Pump Armor to leave a protective coating to prevent freezing or corrosion.
Graco 17C305 — Operation diagram (page 21)
Fig. 43 · Operation
12. Turn pressure control knob to the lowest pressure setting and turn ON/OFF switch to OFF position. Disconnect power to sprayer.
Graco 17C305 — Operation diagram (page 21)
Fig. 44 · Operation
15. Wipe sprayer, hose and gun with a rag soaked in water or mineral spirits.
Graco 17C305 — Operation diagram (page 21)
Fig. 45 · Operation
13. Remove filter from gun and sprayer if installed. Clean and inspect. Install filter. See separate gun manual.
Page 22 of the Graco 17C305 user manual — Activity Interval
Page 22 · click to enlarge
Page 22

Maintenance

Maintenance

Routine maintenance is important to ensure proper operation of your sprayer. Maintenance includes performing routine actions which keep your sprayer in operation and prevents trouble in the future.

Activity Interval

Inspect/clean sprayer filter, fluid inlet strainer, and gun filter.

Daily or each time you spray

Inspect motor shield vents for blockage. Daily or each time you spray Fill TSL by adding through TSL fill point. Daily or each time you spray Inspect motor brushes for wear. Brushes must be 1/2 in. (13mm) minimum length. NOTE: Brushes do not wear at the same rate on both sides of motor. Check both brushes.

Every 1000 gallons (3785 liters)

Check sprayer stall.

Every 1000 gallons (3785 liters)

With sprayer gun NOT triggered, sprayer motor should stall and not restart until gun is triggered again.

If sprayer starts again with gun NOT triggered, inspect pump for internal/external leaks and check prime valve for leaks.

As necessary based on usage

When pump packing begins to leak after extended use, tighten packing nut down until leakage stops or lessens. This allows approximately 100 gallons of additional operation before a repacking is required. Packing nut can be tightened without O-ring removal.

Throat packing adjustment

Page 23 of the Graco 17C305 user manual — What to Check If check is OK, go to next
Page 23 · click to enlarge
Page 23

Troubleshooting

Troubleshooting

Mechanical/Fluid Flow

1. Follow Pressure Relief Procedure , page 10, before checking or repairing.
2. Check all possible problems and causes before disassembling the unit.

What to Check If check is OK, go to next

What to Do When check is not OK,

Problem

check

refer to this column

Pump output is low Spray tip worn. Follow Pressure Relief Procedure, page 10, then replace tip. See separate gun or tip manual.

Spray tip clogged. Relieve pressure. Check and clean spray tip.

Paint supply. Refill and reprime pump.

Intake strainer clogged. Remove and clean, then reinstall.

Intake valve ball and piston ball are not seating properly.

Remove intake valve and clean. Check balls and seats for nicks; replace if necessary. See pump manual. Strain paint before using to remove particles that could clog pump.

Fluid filter or tip filter is clogged or dirty.

Clean filter.

Prime valve leaking. Follow Pressure Relief Procedure, page 10, then repair prime valve.

Verify pump does not continue to stroke when gun trigger is released. (Prime valve not leaking.)

Service pump. See pump manual.

Leaking around throat packing nut which may indicate worn or damaged packings.

Replace packings. See pump manual. Also check piston valve seat for hardened paint or nicks and replace if necessary. Tighten packing nut/wet-cup.

Page 24 of the Graco 17C305 user manual — What to Check If check is OK, go to next
Page 24 · click to enlarge
Page 24

Troubleshooting

What to Check If check is OK, go to next

What to Do When check is not OK,

Problem

check

refer to this column

Pump output is low Pump rod damage. Repair pump. See pump manual.

Low stall pressure. Turn pressure knob fully clockwise. Make sure pressure control knob is properly installed to allow full clockwise position. If problem persists, replace pressure control.

Piston packings are worn or damaged.

Replace packings. See pump manual.

O-ring in pump is worn or damaged. Replace o-ring. See pump manual.

Intake valve ball is packed with material.

Clean intake valve. See pump manual.

Large pressure drop in hose with heavy materials.

Reduce overall length of hose.

Check extension cord for correct size. See Extension Cords, page 9.

Loose motor brushes and terminals. Tighten terminal screws. Replace brushes if leads are damaged.

Worn motor brushes. (Brushes must be 1/2 in. [13mm] minimum length).

Replace brushes.

Broken and misaligned motor brush springs. Rolled portion of spring must rest squarely on top of brush.

Replace spring if broken. Realign spring with brush.

Motor brushes are binding in brush holders.

Clean brush holders, remove carbon dust with a small cleaning brush. Align brush lead with slot in brush holder to assure free vertical brush movement.

Motor runs but pump does not stroke Connecting rod assembly damaged. See pump manual.

Replace connecting rod assembly. See pump manual.

Gears or drive housing damaged. Inspect drive housing assembly and gears for damage and replace if necessary.

Excessive paint leakage into throat packing nut

Throat packing nut is loose. Remove throat packing nut spacer. Tighten throat packing nut just enough to stop leakage.

Throat packings are worn or damaged.

Replace packings. See pump manual.

Displacement rod is worn or damaged.

Replace rod. See pump manual.

Page 25 of the Graco 17C305 user manual — What to Check If check is OK, go to next
Page 25 · click to enlarge
Page 25

Troubleshooting

What to Check If check is OK, go to next

What to Do When check is not OK,

Problem

check

refer to this column

Fluid is spitting from gun Air in pump or hose. Check and tighten all fluid connections. Cycle pump as slowly as possible during priming.

Spray tip is partially clogged. Clear tip. See Clear Tip Clog, page 18.

Fluid supply is low or empty. Refill fluid supply. Prime pump. See pump manual. Check fluid supply often to prevent running pump dry.

Pump is difficult to prime Air in pump or hose. Check and tighten all fluid connections. Cycle pump as slowly as possible during priming.

Intake valve is leaking. Clean intake valve. Be sure ball seat is not nicked or worn and that ball seats well. Reassemble valve.

Pump packings are worn. Replace pump packings. See pump manual.

Paint is too thick. Thin the paint according to supplier recommendations.

Sprayer operates for 5 to 10 minutes then stops

Pump packing nut too tight. When pump packing nut is too tight the packings on the pump rod restrict pump action and overloads the motor.

Loosen pump packing nut. Check for leaks around throat. If necessary, replace pump packings. See Pump manual.

Page 26 of the Graco 17C305 user manual — Problem What to Check How to check
Page 26 · click to enlarge
Page 26

Troubleshooting

Electrical

2. Turn the ON/OFF switch OFF wait 30 seconds and then turn power back ON again (this ensures sprayer is in normal run mode).

Symptom: Sprayer does not run, stops running, or will not shut off.

3. Turn pressure control knob clockwise 1/2 turn.

Keep clear of electrical and moving parts during troubleshooting procedures. To avoid electrical shock hazards when covers are removed for troubleshooting, wait 7 seconds after disconnecting power cord for stored electricity to dissipate.

Perform Pressure Relief Procedure, page 10.

1. Plug sprayer into correct voltage, grounded outlet.

Problem What to Check How to check

Sprayer does not run at all. Check electrical supply. Make certain that there is 120VAC voltage.

Check pressure control connections. Make certain connector is clean and firmly connected.

Check pressure control. Connect known good pressure control. If the motor runs, replace pressure control.

Check replaceable fuse. With sprayer unplugged (no power applied), make certain there is continuity through the fuse.

Check motor leads. Make certain terminals are clean and firmly connected.

Page 27 of the Graco 17C305 user manual — Electrical
Page 27 · click to enlarge
Page 27
Graco 17C305 — Electrical diagram (page 27)
Fig. 46 · Electrical

Check motor rotation. Perform a spin test by connecting a 9 –12 Volt battery to the motor leads. Motor leads may vary in style and size. Locate the two wires going to the carbon brushes normally Red and Black. Motor should spin when battery is connected to the motor leads.

Check motor thermal switch. Motor should be at ambient temperature for this test. Connect the yellow leads from the motor to an Ohm meter. Meter should indicate continuity.

Page 28 of the Graco 17C305 user manual — Electrical
Page 28 · click to enlarge
Page 28
Graco 17C305 — Electrical diagram (page 28)
Fig. 47 · Electrical

Check motor armature resistance. Connect the Red and Black leads from the motor to an Ohm meter. Rotate the motor while checking for opens. If an open is found replace the motor.

Check for motor short. Use an Ohm meter to check motor for shorts. Connect (–) meter lead to motor case. Move the (+) meter lead to each motor wire. Meter should read open on all wires.

Page 29 of the Graco 17C305 user manual — Problem What to Check How to check
Page 29 · click to enlarge
Page 29

Troubleshooting

Problem What to Check How to check

Sprayer will not shut off after reaching or exceeding maximum pressure.

Check pressure control. Disconnect pressure control, if sprayer still runs, replace control board. If the sprayer stops, replace pressure control.

Basic electrical problems Motor leads are securely fastened and properly mated

Replace loose terminals; crimp to leads. Be sure terminal are firmly connected. Clean circuit board terminals. Securely reconnect leads.

For loose motor brush lead connections and terminals.

Tighten terminal screws. Replace brushes if leads are damaged.

Brushes must be 1/2 in. [13mm] minimum. NOTE: Brushes do not wear at the same rate on both sides of motor. Check both brushes.

Replace brushes.

Broken or misaligned motor brush springs. Rolled portion of spring must rest squarely on top of brush.

Replace spring if broken. Realign spring with brush.

Motor brushes may be binding in brush holders.

Clean brush holders. Remove carbon with small cleaning brush. Align brush leads with slot in brush holder to assure free vertical brush movement.

Motor armature commutator for burn spots, gouges or extreme roughness.

Remove motor and have motor shop resurface commutator if possible.

Page 30 of the Graco 17C305 user manual — Stand Model Sprayer Parts
Page 30 · click to enlarge
Page 30

Stand Model Sprayer Parts

Stand Model Sprayer Parts

Graco 17C305 — Stand Model Sprayer Parts diagram (page 30)
Fig. 48 · Stand Model Sprayer Parts
Graco 17C305 — Stand Model Sprayer Parts diagram (page 30)
Fig. 49 · Stand Model Sprayer Parts
Page 31 of the Graco 17C305 user manual — Stand Model Sprayer Parts
Page 31 · click to enlarge
Page 31

Stand Model Sprayer Parts

Graco 17C305 — Stand Model Sprayer Parts diagram (page 31)
Fig. 50 · Stand Model Sprayer Parts
Graco 17C305 — Stand Model Sprayer Parts diagram (page 31)
Fig. 51 · Stand Model Sprayer Parts
Page 32 of the Graco 17C305 user manual — Stand Model Sprayer Parts
Page 32 · click to enlarge
Page 32

Stand Model Sprayer Parts

Stand Model Parts List

Ref. Part Description Qty. 7 115498 SCREW, mch, slot/hex, wash hd

Ref. Part Description Qty.

54b 17C583 FAN, motor, roller, clutch

12 117501 SCREW, mach, slot hex wash hd

54c 16X726 WASHER, shim, round 1 55 15E818 TUBE, drain 1 56 15J743 CORD, power 1 59 15E823 FRAME, stand mount 1 60 257407 HOSE, suction set 1 62 404989 STRAP, tie 1 6315K359 LABEL, warning 1 65195833 LABEL, warning icons intl

14 117559 O-RING 2 20 249051 KIT, tube, drain includes 39,55, 62, 145

22 17C540 COVER, front 1 23 5E341 SHIELD, motor includes 48, 62, 65

25 180131 BEARING, thrust 1 27 247340 HOSE, cpld, 1/4 in. x 50 ft

66 116139 GRIP, handle 1 67 15G857 CAP, leg 4 68 287903 CUP, suction/drain 1 69 287072 HANDLE includes 47, 66 1

28 243012 GUN, spray 1 34222385 CARD, medical alert (not shown)

36189930 LABEL, caution 1 37 235004 STRAINER, 7/8-14 unf 1 39 244035 DEFLECTOR, barbed 1 40 249194 GEAR, reducer 1 41 17C721 PUMP, displacement 1 42 24W817 HOUSING, drive includes 47

70 17C483 COVER, pump rod 1 71 122667 SCREW, drill, hex washer head

89 288686 ADAPTER, power, flush

91 115099 WASHER 1 93 115648 VALVE, shutoff 1 132 16H137 PACKING, O-RING 1 145 M70809 FITTING, barbed, hose 1 165 16Y318 WASHER, flat, #8 2

43 24W640 ROD, connecting 1 44 24X020 GEAR, crankshaft includes 25

45 24W830 KIT, hose, cpld includes 132

206994 FLUID, TSL, 8 oz (not shown)

47 117493 SCREW, mach, hex washer hd

* For motor brush kit order 249042

52 17D602 LABEL, front 1 53 17D603 LABEL, side 1 54 * 17C794 KIT, motor, electric, 110/120Vincludes 54a, 54b, 54c

288526 – Kit, accessory, hopper

Replacement Danger and Warning labels, tags, and cards are available at no cost.

54a 119653 RING, retaining, E-ring 1

Page 33 of the Graco 17C305 user manual — Hi-Boy Sprayers Parts
Page 33 · click to enlarge
Page 33

Hi-Boy Sprayers Parts

Hi-Boy Sprayers Parts

Graco 17C305 — Hi-Boy Sprayers Parts diagram (page 33)
Fig. 52 · Hi-Boy Sprayers Parts
Page 34 of the Graco 17C305 user manual — Hi-Boy Sprayers Parts
Page 34 · click to enlarge
Page 34

Hi-Boy Sprayers Parts

Graco 17C305 — Hi-Boy Sprayers Parts diagram (page 34)
Fig. 53 · Hi-Boy Sprayers Parts
Page 35 of the Graco 17C305 user manual — Hi-Boy Sprayers Parts
Page 35 · click to enlarge
Page 35

Hi-Boy Sprayers Parts

Hi-Boy Sprayers Parts List

Ref. Part Description Qty. 7 115498 SCREW, mch, slot/hex, wash hd

Ref. Part Description Qty.

54a 17C583 FAN, motor, roller, clutch

12 117501 SCREW, mach, slot hex wash hd

54b 16X726 WASHER, shim, round 1 54c 119653 RING, retaining, E-ring 1 55 15K092 TUBE, drain 1 59 17C485 FRAME, cart universal 1 60 15J801 HOSE, suction set 1 62 195400 CLIP, spring 1 6315K359 LABEL, warnings 1 65195793 LABEL, warning 1 67 109032 SCREW, mach, pnh 4 68 119452 CAP, hub 2 69 287489 HANDLE assy, hi cart 1 70 17C483 COVER, pump rod 1 74 119451 WHEEL, semi-pneumatic

14 103413 PACKING, O-ring 1 22 17C540 COVER, front 1 23 255165 SHIELD, motor includes 48, 62, 65

25 180131 BEARING, thrust 1 27 247340 HOSE, cpld, 1/4 in. x 25 or 50 ft 1

28 243012 GUN, spray 1 34222385 CARD, medical alert (not shown)

36189930 LABEL, caution 1 37 235004 STRAINER, 7/8-14 unf 1 39 244035 DEFLECTOR, barbed 1 40 249194 GEAR, reducer 1 41 17C721 PUMP, displacement 1 42 24W817 HOUSING, drive includes 47

87 15B652 WASHER, suction 1 89 288686 ADAPTER, power, flush

91 115099 WASHER 1 93 115648 VALVE, shutoff 1 95 15E813 NUT, jam 1 132 16H137 PACKING, O-ring 1 136 17C990 HANGER, pail 1 137 111040 NUT, lock, insert 2 145 M70809 FITTING, barbed, hose 1 206994 FLUID, TSL, 8 oz (not shown)

43 24W640 ROD, connecting 1 44 24X020 GEAR, crankshaft includes 25

45 24W830 KIT, hose, cpld includes 132

46 108691 PLUG, tubing 2 47 117493 SCREW, mach, hex washer hd

48 114531 SCREW, mach, hex washer hd

* For motor brush kit order 249042

52 17D602 LABEL, front 1 53 17D603 LABEL, side 1 54 * 17C794 KIT, motor, electric includes 54, 54b, 54c

Replacement Danger and Warning labels, tags, and cards are available at no cost.

Page 36 of the Graco 17C305 user manual — Control Box and Filter
Page 36 · click to enlarge
Page 36

Control Box and Filter

Control Box and Filter

Graco 17C305 — Control Box and Filter diagram (page 36)
Fig. 54 · Control Box and Filter
Page 37 of the Graco 17C305 user manual — Control Box and Filter
Page 37 · click to enlarge
Page 37

Control Box and Filter

Control and Filter Parts List

Ref. Part Description Qty. 2 104361 PACKING, o-ring 1 4 111600 PIN, grooved 1 5 277364 GASKET, seat, valve 1 12 117501 SCREW, mach, hex washer hd

Ref. Part Description Qty.

26 15E022 SEAT, valve 1 27 187625 HANDLE, valve, drain 1 35 239914 VALVE, drain, includes 5, 26 1

36 224807 BASE, valve 1 38 24X312 KIT, control, pressure, includes 19, 21, 51, 153

15 17C592 MANIFOLD, fluid 1 16 FILTER, fluid 1 243080 60 mesh, original 243081 100 mesh 17 243102 KIT, cap, short manifold, includes 18, 16 (60 mesh)

49 249052 BOARD, control 1 51 15A464 LABEL, control 1 56 15J743 CORD, power 1 97 17C735 SCREW, mach, HWH 2 146 17D294 SPACER, manifold 2 150 119277 Fuse replacement 1 153 17C831 LABEL, control 1 154 195811 LABEL, instructions 1 155 195707 LABEL, instructions 1

18 15E288 INSERT, filter 1 19 115756 BUSHING, motor wire 1 21 17C725 INDICATOR, control pressure

24 162453 NIPPLE, (1/4 npsm x 1/4 npt) 2

Page 38 of the Graco 17C305 user manual — Wiring Diagram
Page 38 · click to enlarge
Page 38

Wiring Diagram

Wiring Diagram

Graco 17C305 — Wiring Diagram diagram (page 38)
Fig. 55 · Wiring Diagram
Page 39 of the Graco 17C305 user manual — Technical Specifications
Page 39 · click to enlarge
Page 39

Technical Specifications

Technical Specifications

17D163, 17C305 US Metric Sprayer Maximum fluid working pressure 3000 psi 207 bar, 20.7 MPa Maximum Delivery 0.47 gpm 2.1 lpm Maximum Tip Size 0.021 0.021 Fluid Outlet npsm 1/4 in. 1/4 in. Cycles 700 per gallon 185 per liter Generator Minimum 3000 W 3000 W 110–120V, A, Hz 1Ø, 13, 50/60 Dimensions Height

Stand 21 in. 53.3 cm Hi-Boy 29.5 in. (Handle down) 39.5 in. (Handle up) 74.9 cm (Handle down) 100.3 cm (Handle up) Length

Stand 15 in. 38.1 cm Hi-Boy 21 in. 53.3 cm Width

Stand 14 in. 35.6 cm Hi-Boy 20.5 in. 52.1 cm Weight

Stand 34 lb. 15.4 kg Hi-Boy 62 lb. 28.1 kg

Noise** (dBa) @ 70 psi (0.48 MPa, 4.8 bar)

Sound pressure 90 dBa Sound power 100 dBa Materials of Construction Wetted materials on all models zinc- and nickel-plated carbon steel, nylon, stainless steel, PTFE, Acetal, leather, UHMWPE, aluminum, tungsten carbide, polyethylene, fluoroelastomer, urethane Notes * Startup pressures and displacement per cycle may vary based on suction condition, discharge head, air pressure, and fluid type.

** Sound pressure measured 3 feet (1 meter) from equipment.

Sound power measured per ISO-3744.

Page 40 of the Graco 17C305 user manual — Graco Standard Warranty
Page 40 · click to enlarge
Page 40

Graco Standard Warranty

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Page 41 of the Graco 17C305 user manual — Graco Information
Page 41 · click to enlarge
Page 41

Graco Information

For the latest information about Graco products, visit www.graco.com

For patent information, see www.graco.com/patents

TO PLACE AN ORDER, contact your Graco distributor or call 1-800-690-2894 to identify the nearest distributor.

All written and visual data contained in this document reflects the latest product information available at

the time of publication. Graco reserves the right to make changes at any time without notice.

Original instructions. This manual contains English. MM 334659

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea
  • GRACO INC. AND SUBSIDIARIES
  • P.O. BOX 1441
  • MINNEAPOLIS MN 55440-1441
  • USA

Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com Revision A, December 2014

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Pump output is lowSpray tip worn. p.23
Pump output is lowSpray tip clogged. p.23
Pump output is lowPaint supply. p.23
Pump output is lowIntake strainer clogged. p.23
Pump output is lowIntake valve ball and piston ball are not seating properly. p.23
Pump output is lowFluid filter or tip filter is clogged or dirty. p.23
Pump output is lowPrime valve leaking. p.23
Pump output is lowVerify pump does not continue to stroke when gun trigger is released. (Prime valve not leaking.) p.23
Pump output is lowLeaking around throat packing nut which may indicate worn or damaged packings. p.23
Pump output is lowPump rod damage. p.24
Pump output is lowLow stall pressure. p.24
Pump output is lowPiston packings are worn or damaged. p.24
Pump output is lowO-ring in pump is worn or damaged. p.24
Pump output is lowIntake valve ball is packed with material. p.24
Pump output is lowLarge pressure drop in hose with heavy materials. p.24
Pump output is lowCheck extension cord for correct size. p.24
Pump output is lowLoose motor brushes and terminals. p.24
Pump output is lowWorn motor brushes. (Brushes must be 1/2 in. [13mm] minimum length). p.24
Pump output is lowBroken and misaligned motor brush springs. Rolled portion of spring must rest squarely on top of brush. p.24
Pump output is lowMotor brushes are binding in brush holders. p.24
Motor runs but pump does not strokeConnecting rod assembly damaged. See pump manual. p.24
Motor runs but pump does not strokeGears or drive housing damaged. p.24
Excessive paint leakage into throat packing nutThroat packing nut is loose. p.24
Excessive paint leakage into throat packing nutThroat packings are worn or damaged. p.24
Excessive paint leakage into throat packing nutDisplacement rod is worn or damaged. p.24
Fluid is spitting from gunAir in pump or hose. p.25
Fluid is spitting from gunSpray tip is partially clogged. p.25
Fluid is spitting from gunFluid supply is low or empty. p.25
Pump is difficult to primeAir in pump or hose. p.25
Pump is difficult to primeIntake valve is leaking. p.25
Pump is difficult to primePump packings are worn. p.25
Pump is difficult to primePaint is too thick. p.25
Sprayer operates for 5 to 10 minutes then stopsPump packing nut too tight. When pump packing nut is too tight the packings on the pump rod restrict pump action and overloads the motor. p.25
Sprayer does not run at all.Check electrical supply. Check pressure control connections. Check pressure control. Check replaceable fuse. Check motor leads. p.26
Sprayer does not run at all. p.26
Check motor rotation. p.27
Check motor thermal switch. p.27
Check motor armature resistance. p.28
Check for motor short. p.28
Sprayer will not shut off after reaching or exceeding maximum pressure.Check pressure control. p.29
Basic electrical problemsMotor leads are securely fastened and properly mated p.29
Basic electrical problemsFor loose motor brush lead connections and terminals. p.29
Basic electrical problemsBrushes must be 1/2 in. [13mm] minimum. NOTE: Brushes do not wear at the same rate on both sides of motor. Check both brushes. p.29
Basic electrical problemsBroken or misaligned motor brush springs. Rolled portion of spring must rest squarely on top of brush. p.29
Basic electrical problemsMotor brushes may be binding in brush holders. p.29
Basic electrical problemsMotor armature commutator for burn spots, gouges or extreme roughness. p.29

Ask about the Graco 17C305

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 17C305

Be the first to ask — other owners or our team will answer.

Original document

Graco 17C305 manual PDF

41 pages·12 MB·Paint Sprayer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…