210 ES Electric Airless Sprayers
For professional use only. Not approved for use in explosive atmospheres or hazardous locations. For portable airless spraying of architectural paints and coatings.
3000 psi (207 bar, 20.7 MPa) Maximum Working Pressure

Use only genuine Graco replacement parts. The use of non-Graco replacement parts may void warranty.


Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.



This product contains a chemical known to the State of California to cause cancer, birth defects or other reproductive harm. Wash hands after handling.

Component Identification
Stand Model

A ON/OFF Switch B Pressure Control D Prime Valve F Tip Guard G Spray Tip H Gun J Airless Hose K Power Cord L Trigger Lock
M Drain Tube N Fluid Intake P Pump R Fluid Outlet S Power Cord Wrap U Filter V Finger Guard / TSL Fill Point Model/Serial Tag (Not shown, located on bottom of unit.)

Hi-Boy Models

M Drain Tube N Fluid Intake P Pump R Fluid Outlet S Hanger T Filter U Finger Guard / TSL Fill Point V Pail Hook Model/Serial Tag (Not shown, located on bottom of unit.)

Grounding


The equipment must be grounded to reduce the risk of static sparking and electric shock. An electric or static spark can cause fumes to ignite or explode. An improper ground can cause electric shock. A good ground provides an escape wire for the electric current.
Always ground a metal pail: connect a ground wire to the pail. Clamp one end to the pail and the other end to a true earth ground such as a water pipe.
This sprayer includes a ground wire with an appropriate ground contact.
The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qualified electrician.
110-120V units require 100-120 VAC, 50/60 Hz, 13A, 1 phase.
To maintain ground continuity when sprayer is flushed or pressure is relieved: hold metal part of spray gun firmly to the side of a grounded metal pail then trigger the gun.
Use an extension cord with an undamaged ground contact. If an extension cord is necessary, use a 3-wire, 12 AWG (2.5 mm2) minimum.

Solvent and oil-based fluids: follow local code. Use only conductive metal pails, placed on a grounded surface such as concrete.
Do not place pail on a non-conductive surface such as paper or cardboard which interrupts grounding continuity.

Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever you see this symbol.


This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashed fluid and moving parts, follow the Pressure Relief Procedure whenever sprayer is stopped and before sprayer is cleaned or checked, and before equipment is serviced.



a. VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually.
b. Loosen nut or coupling completely. c. Clear hose or tip obstruction.

Always engage the trigger lock when sprayer is stopped to prevent the gun from being triggered accidentally by hand or if dropped or bumped.


Setup


When unpacking sprayer for the first time or after long term storage perform setup procedure. When first setup is performed remove shipping plug from fluid outlet.




a. Place the TSL bottle nozzle into the top center opening in the grill at the front of the sprayer.

b. Squeeze bottle to dispense enough TSL to fill the space between the pump rod and packing nut seal.





Startup








High-pressure spray is able to inject toxins into the body and cause serious bodily injury. Do not stop leaks with hand or rag.

Operation
Spray Tip Installation




Clear Tip Clog



Cleanup














Maintenance
Routine maintenance is important to ensure proper operation of your sprayer. Maintenance includes performing routine actions which keep your sprayer in operation and prevents trouble in the future.
Inspect/clean sprayer filter, fluid inlet strainer, and gun filter.
Daily or each time you spray
Inspect motor shield vents for blockage. Daily or each time you spray Fill TSL by adding through TSL fill point. Daily or each time you spray Inspect motor brushes for wear. Brushes must be 1/2 in. (13mm) minimum length. NOTE: Brushes do not wear at the same rate on both sides of motor. Check both brushes.
Every 1000 gallons (3785 liters)
Check sprayer stall.
Every 1000 gallons (3785 liters)
With sprayer gun NOT triggered, sprayer motor should stall and not restart until gun is triggered again.
If sprayer starts again with gun NOT triggered, inspect pump for internal/external leaks and check prime valve for leaks.
As necessary based on usage
When pump packing begins to leak after extended use, tighten packing nut down until leakage stops or lessens. This allows approximately 100 gallons of additional operation before a repacking is required. Packing nut can be tightened without O-ring removal.
Throat packing adjustment

Troubleshooting
Mechanical/Fluid Flow
What to Do When check is not OK,
Problem
check
refer to this column
Pump output is low Spray tip worn. Follow Pressure Relief Procedure, page 10, then replace tip. See separate gun or tip manual.
Spray tip clogged. Relieve pressure. Check and clean spray tip.
Paint supply. Refill and reprime pump.
Intake strainer clogged. Remove and clean, then reinstall.
Intake valve ball and piston ball are not seating properly.
Remove intake valve and clean. Check balls and seats for nicks; replace if necessary. See pump manual. Strain paint before using to remove particles that could clog pump.
Fluid filter or tip filter is clogged or dirty.
Clean filter.
Prime valve leaking. Follow Pressure Relief Procedure, page 10, then repair prime valve.
Verify pump does not continue to stroke when gun trigger is released. (Prime valve not leaking.)
Service pump. See pump manual.
Leaking around throat packing nut which may indicate worn or damaged packings.
Replace packings. See pump manual. Also check piston valve seat for hardened paint or nicks and replace if necessary. Tighten packing nut/wet-cup.

What to Do When check is not OK,
Problem
check
refer to this column
Pump output is low Pump rod damage. Repair pump. See pump manual.
Low stall pressure. Turn pressure knob fully clockwise. Make sure pressure control knob is properly installed to allow full clockwise position. If problem persists, replace pressure control.
Piston packings are worn or damaged.
Replace packings. See pump manual.
O-ring in pump is worn or damaged. Replace o-ring. See pump manual.
Intake valve ball is packed with material.
Clean intake valve. See pump manual.
Large pressure drop in hose with heavy materials.
Reduce overall length of hose.
Check extension cord for correct size. See Extension Cords, page 9.
Loose motor brushes and terminals. Tighten terminal screws. Replace brushes if leads are damaged.
Worn motor brushes. (Brushes must be 1/2 in. [13mm] minimum length).
Replace brushes.
Broken and misaligned motor brush springs. Rolled portion of spring must rest squarely on top of brush.
Replace spring if broken. Realign spring with brush.
Motor brushes are binding in brush holders.
Clean brush holders, remove carbon dust with a small cleaning brush. Align brush lead with slot in brush holder to assure free vertical brush movement.
Motor runs but pump does not stroke Connecting rod assembly damaged. See pump manual.
Replace connecting rod assembly. See pump manual.
Gears or drive housing damaged. Inspect drive housing assembly and gears for damage and replace if necessary.
Excessive paint leakage into throat packing nut
Throat packing nut is loose. Remove throat packing nut spacer. Tighten throat packing nut just enough to stop leakage.
Throat packings are worn or damaged.
Replace packings. See pump manual.
Displacement rod is worn or damaged.
Replace rod. See pump manual.

What to Do When check is not OK,
Problem
check
refer to this column
Fluid is spitting from gun Air in pump or hose. Check and tighten all fluid connections. Cycle pump as slowly as possible during priming.
Spray tip is partially clogged. Clear tip. See Clear Tip Clog, page 18.
Fluid supply is low or empty. Refill fluid supply. Prime pump. See pump manual. Check fluid supply often to prevent running pump dry.
Pump is difficult to prime Air in pump or hose. Check and tighten all fluid connections. Cycle pump as slowly as possible during priming.
Intake valve is leaking. Clean intake valve. Be sure ball seat is not nicked or worn and that ball seats well. Reassemble valve.
Pump packings are worn. Replace pump packings. See pump manual.
Paint is too thick. Thin the paint according to supplier recommendations.
Sprayer operates for 5 to 10 minutes then stops
Pump packing nut too tight. When pump packing nut is too tight the packings on the pump rod restrict pump action and overloads the motor.
Loosen pump packing nut. Check for leaks around throat. If necessary, replace pump packings. See Pump manual.

Electrical
Symptom: Sprayer does not run, stops running, or will not shut off.
Keep clear of electrical and moving parts during troubleshooting procedures. To avoid electrical shock hazards when covers are removed for troubleshooting, wait 7 seconds after disconnecting power cord for stored electricity to dissipate.
Perform Pressure Relief Procedure, page 10.
Sprayer does not run at all. Check electrical supply. Make certain that there is 120VAC voltage.
Check pressure control connections. Make certain connector is clean and firmly connected.
Check pressure control. Connect known good pressure control. If the motor runs, replace pressure control.
Check replaceable fuse. With sprayer unplugged (no power applied), make certain there is continuity through the fuse.
Check motor leads. Make certain terminals are clean and firmly connected.


Check motor rotation. Perform a spin test by connecting a 9 –12 Volt battery to the motor leads. Motor leads may vary in style and size. Locate the two wires going to the carbon brushes normally Red and Black. Motor should spin when battery is connected to the motor leads.
Check motor thermal switch. Motor should be at ambient temperature for this test. Connect the yellow leads from the motor to an Ohm meter. Meter should indicate continuity.


Check motor armature resistance. Connect the Red and Black leads from the motor to an Ohm meter. Rotate the motor while checking for opens. If an open is found replace the motor.
Check for motor short. Use an Ohm meter to check motor for shorts. Connect (–) meter lead to motor case. Move the (+) meter lead to each motor wire. Meter should read open on all wires.

Sprayer will not shut off after reaching or exceeding maximum pressure.
Check pressure control. Disconnect pressure control, if sprayer still runs, replace control board. If the sprayer stops, replace pressure control.
Basic electrical problems Motor leads are securely fastened and properly mated
Replace loose terminals; crimp to leads. Be sure terminal are firmly connected. Clean circuit board terminals. Securely reconnect leads.
For loose motor brush lead connections and terminals.
Tighten terminal screws. Replace brushes if leads are damaged.
Brushes must be 1/2 in. [13mm] minimum. NOTE: Brushes do not wear at the same rate on both sides of motor. Check both brushes.
Replace brushes.
Broken or misaligned motor brush springs. Rolled portion of spring must rest squarely on top of brush.
Replace spring if broken. Realign spring with brush.
Motor brushes may be binding in brush holders.
Clean brush holders. Remove carbon with small cleaning brush. Align brush leads with slot in brush holder to assure free vertical brush movement.
Motor armature commutator for burn spots, gouges or extreme roughness.
Remove motor and have motor shop resurface commutator if possible.

Stand Model Sprayer Parts






Stand Model Parts List
Ref. Part Description Qty. 7 115498 SCREW, mch, slot/hex, wash hd
Ref. Part Description Qty.
54b 17C583 FAN, motor, roller, clutch
12 117501 SCREW, mach, slot hex wash hd
54c 16X726 WASHER, shim, round 1 55 15E818 TUBE, drain 1 56 15J743 CORD, power 1 59 15E823 FRAME, stand mount 1 60 257407 HOSE, suction set 1 62 404989 STRAP, tie 1 6315K359 LABEL, warning 1 65195833 LABEL, warning icons intl
14 117559 O-RING 2 20 249051 KIT, tube, drain includes 39,55, 62, 145
22 17C540 COVER, front 1 23 5E341 SHIELD, motor includes 48, 62, 65
25 180131 BEARING, thrust 1 27 247340 HOSE, cpld, 1/4 in. x 50 ft
66 116139 GRIP, handle 1 67 15G857 CAP, leg 4 68 287903 CUP, suction/drain 1 69 287072 HANDLE includes 47, 66 1
28 243012 GUN, spray 1 34222385 CARD, medical alert (not shown)
36189930 LABEL, caution 1 37 235004 STRAINER, 7/8-14 unf 1 39 244035 DEFLECTOR, barbed 1 40 249194 GEAR, reducer 1 41 17C721 PUMP, displacement 1 42 24W817 HOUSING, drive includes 47
70 17C483 COVER, pump rod 1 71 122667 SCREW, drill, hex washer head
89 288686 ADAPTER, power, flush
91 115099 WASHER 1 93 115648 VALVE, shutoff 1 132 16H137 PACKING, O-RING 1 145 M70809 FITTING, barbed, hose 1 165 16Y318 WASHER, flat, #8 2
43 24W640 ROD, connecting 1 44 24X020 GEAR, crankshaft includes 25
45 24W830 KIT, hose, cpld includes 132
206994 FLUID, TSL, 8 oz (not shown)
47 117493 SCREW, mach, hex washer hd
* For motor brush kit order 249042
52 17D602 LABEL, front 1 53 17D603 LABEL, side 1 54 * 17C794 KIT, motor, electric, 110/120Vincludes 54a, 54b, 54c
288526 – Kit, accessory, hopper
Replacement Danger and Warning labels, tags, and cards are available at no cost.
54a 119653 RING, retaining, E-ring 1

Hi-Boy Sprayers Parts




Hi-Boy Sprayers Parts List
Ref. Part Description Qty. 7 115498 SCREW, mch, slot/hex, wash hd
Ref. Part Description Qty.
54a 17C583 FAN, motor, roller, clutch
12 117501 SCREW, mach, slot hex wash hd
54b 16X726 WASHER, shim, round 1 54c 119653 RING, retaining, E-ring 1 55 15K092 TUBE, drain 1 59 17C485 FRAME, cart universal 1 60 15J801 HOSE, suction set 1 62 195400 CLIP, spring 1 6315K359 LABEL, warnings 1 65195793 LABEL, warning 1 67 109032 SCREW, mach, pnh 4 68 119452 CAP, hub 2 69 287489 HANDLE assy, hi cart 1 70 17C483 COVER, pump rod 1 74 119451 WHEEL, semi-pneumatic
14 103413 PACKING, O-ring 1 22 17C540 COVER, front 1 23 255165 SHIELD, motor includes 48, 62, 65
25 180131 BEARING, thrust 1 27 247340 HOSE, cpld, 1/4 in. x 25 or 50 ft 1
28 243012 GUN, spray 1 34222385 CARD, medical alert (not shown)
36189930 LABEL, caution 1 37 235004 STRAINER, 7/8-14 unf 1 39 244035 DEFLECTOR, barbed 1 40 249194 GEAR, reducer 1 41 17C721 PUMP, displacement 1 42 24W817 HOUSING, drive includes 47
87 15B652 WASHER, suction 1 89 288686 ADAPTER, power, flush
91 115099 WASHER 1 93 115648 VALVE, shutoff 1 95 15E813 NUT, jam 1 132 16H137 PACKING, O-ring 1 136 17C990 HANGER, pail 1 137 111040 NUT, lock, insert 2 145 M70809 FITTING, barbed, hose 1 206994 FLUID, TSL, 8 oz (not shown)
43 24W640 ROD, connecting 1 44 24X020 GEAR, crankshaft includes 25
45 24W830 KIT, hose, cpld includes 132
46 108691 PLUG, tubing 2 47 117493 SCREW, mach, hex washer hd
48 114531 SCREW, mach, hex washer hd
* For motor brush kit order 249042
52 17D602 LABEL, front 1 53 17D603 LABEL, side 1 54 * 17C794 KIT, motor, electric includes 54, 54b, 54c
Replacement Danger and Warning labels, tags, and cards are available at no cost.

Control Box and Filter


Control and Filter Parts List
Ref. Part Description Qty. 2 104361 PACKING, o-ring 1 4 111600 PIN, grooved 1 5 277364 GASKET, seat, valve 1 12 117501 SCREW, mach, hex washer hd
Ref. Part Description Qty.
26 15E022 SEAT, valve 1 27 187625 HANDLE, valve, drain 1 35 239914 VALVE, drain, includes 5, 26 1
36 224807 BASE, valve 1 38 24X312 KIT, control, pressure, includes 19, 21, 51, 153
15 17C592 MANIFOLD, fluid 1 16 FILTER, fluid 1 243080 60 mesh, original 243081 100 mesh 17 243102 KIT, cap, short manifold, includes 18, 16 (60 mesh)
49 249052 BOARD, control 1 51 15A464 LABEL, control 1 56 15J743 CORD, power 1 97 17C735 SCREW, mach, HWH 2 146 17D294 SPACER, manifold 2 150 119277 Fuse replacement 1 153 17C831 LABEL, control 1 154 195811 LABEL, instructions 1 155 195707 LABEL, instructions 1
18 15E288 INSERT, filter 1 19 115756 BUSHING, motor wire 1 21 17C725 INDICATOR, control pressure
24 162453 NIPPLE, (1/4 npsm x 1/4 npt) 2

Wiring Diagram


Technical Specifications
17D163, 17C305 US Metric Sprayer Maximum fluid working pressure 3000 psi 207 bar, 20.7 MPa Maximum Delivery 0.47 gpm 2.1 lpm Maximum Tip Size 0.021 0.021 Fluid Outlet npsm 1/4 in. 1/4 in. Cycles 700 per gallon 185 per liter Generator Minimum 3000 W 3000 W 110–120V, A, Hz 1Ø, 13, 50/60 Dimensions Height
Stand 21 in. 53.3 cm Hi-Boy 29.5 in. (Handle down) 39.5 in. (Handle up) 74.9 cm (Handle down) 100.3 cm (Handle up) Length
Stand 15 in. 38.1 cm Hi-Boy 21 in. 53.3 cm Width
Stand 14 in. 35.6 cm Hi-Boy 20.5 in. 52.1 cm Weight
Stand 34 lb. 15.4 kg Hi-Boy 62 lb. 28.1 kg
Noise** (dBa) @ 70 psi (0.48 MPa, 4.8 bar)
Sound pressure 90 dBa Sound power 100 dBa Materials of Construction Wetted materials on all models zinc- and nickel-plated carbon steel, nylon, stainless steel, PTFE, Acetal, leather, UHMWPE, aluminum, tungsten carbide, polyethylene, fluoroelastomer, urethane Notes * Startup pressures and displacement per cycle may vary based on suction condition, discharge head, air pressure, and fluid type.
** Sound pressure measured 3 feet (1 meter) from equipment.
Sound power measured per ISO-3744.

Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

For the latest information about Graco products, visit www.graco.com
For patent information, see www.graco.com/patents
TO PLACE AN ORDER, contact your Graco distributor or call 1-800-690-2894 to identify the nearest distributor.
All written and visual data contained in this document reflects the latest product information available at
the time of publication. Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 334659
Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Revision A, December 2014
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump output is low | Spray tip worn. | p.23 | |
| Pump output is low | Spray tip clogged. | p.23 | |
| Pump output is low | Paint supply. | p.23 | |
| Pump output is low | Intake strainer clogged. | p.23 | |
| Pump output is low | Intake valve ball and piston ball are not seating properly. | p.23 | |
| Pump output is low | Fluid filter or tip filter is clogged or dirty. | p.23 | |
| Pump output is low | Prime valve leaking. | p.23 | |
| Pump output is low | Verify pump does not continue to stroke when gun trigger is released. (Prime valve not leaking.) | p.23 | |
| Pump output is low | Leaking around throat packing nut which may indicate worn or damaged packings. | p.23 | |
| Pump output is low | Pump rod damage. | p.24 | |
| Pump output is low | Low stall pressure. | p.24 | |
| Pump output is low | Piston packings are worn or damaged. | p.24 | |
| Pump output is low | O-ring in pump is worn or damaged. | p.24 | |
| Pump output is low | Intake valve ball is packed with material. | p.24 | |
| Pump output is low | Large pressure drop in hose with heavy materials. | p.24 | |
| Pump output is low | Check extension cord for correct size. | p.24 | |
| Pump output is low | Loose motor brushes and terminals. | p.24 | |
| Pump output is low | Worn motor brushes. (Brushes must be 1/2 in. [13mm] minimum length). | p.24 | |
| Pump output is low | Broken and misaligned motor brush springs. Rolled portion of spring must rest squarely on top of brush. | p.24 | |
| Pump output is low | Motor brushes are binding in brush holders. | p.24 | |
| Motor runs but pump does not stroke | Connecting rod assembly damaged. See pump manual. | p.24 | |
| Motor runs but pump does not stroke | Gears or drive housing damaged. | p.24 | |
| Excessive paint leakage into throat packing nut | Throat packing nut is loose. | p.24 | |
| Excessive paint leakage into throat packing nut | Throat packings are worn or damaged. | p.24 | |
| Excessive paint leakage into throat packing nut | Displacement rod is worn or damaged. | p.24 | |
| Fluid is spitting from gun | Air in pump or hose. | p.25 | |
| Fluid is spitting from gun | Spray tip is partially clogged. | p.25 | |
| Fluid is spitting from gun | Fluid supply is low or empty. | p.25 | |
| Pump is difficult to prime | Air in pump or hose. | p.25 | |
| Pump is difficult to prime | Intake valve is leaking. | p.25 | |
| Pump is difficult to prime | Pump packings are worn. | p.25 | |
| Pump is difficult to prime | Paint is too thick. | p.25 | |
| Sprayer operates for 5 to 10 minutes then stops | Pump packing nut too tight. When pump packing nut is too tight the packings on the pump rod restrict pump action and overloads the motor. | p.25 | |
| Sprayer does not run at all. | Check electrical supply. Check pressure control connections. Check pressure control. Check replaceable fuse. Check motor leads. | p.26 | |
| Sprayer does not run at all. | p.26 | ||
| Check motor rotation. | p.27 | ||
| Check motor thermal switch. | p.27 | ||
| Check motor armature resistance. | p.28 | ||
| Check for motor short. | p.28 | ||
| Sprayer will not shut off after reaching or exceeding maximum pressure. | Check pressure control. | p.29 | |
| Basic electrical problems | Motor leads are securely fastened and properly mated | p.29 | |
| Basic electrical problems | For loose motor brush lead connections and terminals. | p.29 | |
| Basic electrical problems | Brushes must be 1/2 in. [13mm] minimum. NOTE: Brushes do not wear at the same rate on both sides of motor. Check both brushes. | p.29 | |
| Basic electrical problems | Broken or misaligned motor brush springs. Rolled portion of spring must rest squarely on top of brush. | p.29 | |
| Basic electrical problems | Motor brushes may be binding in brush holders. | p.29 | |
| Basic electrical problems | Motor armature commutator for burn spots, gouges or extreme roughness. | p.29 |
Owners and our team usually reply within a day — and your question helps the next person too.