GENERAC ® EZ SWITCH™

Generac RTS14EZA1 — GENERAC ® EZ SWITCH™ diagram (page 1)
Fig. 1

Pre-wired Automatic Transfer Switch

with Built In Load Center

Generac RTS14EZA1 — Pre-wired Automatic Transfer Switch diagram (page 1)
Fig. 2 · Pre-wired Automatic Transfer Switch

100 Amp, 250 VAC, NEMA 1

Model RTS10EZA1 – 10 Circuit Switch Model RTS12EZA1 – 12 Circuit Switch Model RTS14EZA1 – 14 Circuit Switch Model RTS16EZA1 – 16 Circuit Switch

Generac RTS14EZA1 — 100 Amp, 250 VAC, NEMA 1 diagram (page 1)
Fig. 3 · 100 Amp, 250 VAC, NEMA 1

DESCRIPTION STANDARD FEATURES

The Generac EZ Switch™ is designed to operate with 8-17kW air-cooled generators. This 100 amp Transfer switch has an integrated load center for picking up the emergency circuits. It is especially useful where the main service is large and only a portion of the building load will be served by the generator. It is available with a built in 10, 12, 14 or 16-circuit load center to supply only those circuits that are essential during an emergency. All standard and load center transfer switches are UL and CUL Listed and suitable for use as optional standby systems (NEC702).

All EZ Switches are housed in a steel NEMA 1 enclosure, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The control at the generator handles all the timing, sensing and exercising functions.

CONTACTOR RATING

The transfer switch contactor is rated at 250 VAC and is available in a single phase configuration only.

®

Page 2 of the Generac RTS14EZA1 user manual — W1
Page 2 · click to enlarge
Page 2

Generac EZ Switch™

FUNCTIONS

All Timing and sensing functions originate in the generator controller

Utility voltage drop-out 80% Re-transfer time delay 15 seconds Engine cool-down timer 60 seconds Exerciser 12 minutes every 7 days

The transfer switch can be operated manually without power applied.

SPECIFICATIONS

ModelRTS10EZA1RTS12EZA1RTS14EZA1RTS16EZA1 Voltage240, 1ø240, 1ø240, 1ø240, 1ø Circuits***50A, 240V–––1 40A, 240V–111 30A, 240V11–– 20A, 240V1–11 20A, 120V3365 15A, 120V3545 Phase1 Rated AC Frequency60 Hz Enclosure MaterialSteel Enclosure TypeNEMA 1 Unit Weight (lbs./kilos)57/25.960.8/27.564/2968/30.8 Withstand Rating (Amps)10,000 Lug Range2/0 - #14 Load Transition TypeOpen Transition Wire Gauge (Hot, Neutral, Ground, Control)10, 10, 10, 188, 8, 10, 186, 6, 8, 186, 6, 8, 18

EZ Switch™ Features

W2

  • Electrically operated, mechanically-held contacts for fast, positive connections.
  • Rated for all classes of load, 100% equipment rated, both inductive and resistive.
  • 2 pole, 250 VAC contactors.
  • 160 millisecond transfer time.

H1

  • Dual coil design.

H2

  • Main contacts are silver plated or silver alloy to resist welding and sticking.
  • NEMA 1 (indoor rated) enclosure is standard on the 100 amp switch.
  • 2 Year Limited Warranty

W1

Terminal Wire Ranges ATS Rated AmpsSwitch TerminalNeutral Lug/StudGround Lug 100A 2-Pole UL1 x 1/0-121 x 3/8-16 Stud1 x 2/0-14
Mechanical Dimensions (in inches/mm) Current RatingNo. of PolesHeightWidthDepth H1H2W1 W27/177.8 100 UL Listed226.5/673.129.25/742.9 8.14/206.7 12.5/317.5
  • Generac Power Systems, Inc.
  • S45 W29290 HWY. 59, Waukesha, WI 53189
  • <a href="http://generac.com" rel="nofollow noopener" target="_blank">generac.com</a>

©2012 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0186640SBY-D / Printed in U.S.A. 02/17/12

® · ®

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Generac RTS14EZA1

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Generac RTS14EZA1

Be the first to ask — other owners or our team will answer.

Original document

Generac RTS14EZA1 manual PDF

2 pages·696 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…