Instruction/ maintenance manual of the product 4451 Generac
Go to page of 40
Owner’ s Manual • SAFETY • ASSEMBLY • OPERATION • TROUBLESHOOTING • ELECTRICAL DATA • PARTS • WARRANTY 1-800-333-1322 UL TRA SOURCE Portable Generator COMMERCIAL • INDUSTRIAL • RESIDENTIAL MODELS: 004 4 51 (12,500 W A TT) 004582 (15,000 W A TT) AUTHORIZED DEALER SUPPORT: GENERAC POWER SYSTEMS, INC.
Table of Contents Commercial-Industrial-Residential Portable Generator System Safety Rules ..............................................1-3 Section 1 – General Information ................4 1.1 Unpacking ............................................
INTRODUCTION Thank you for purchasing this model of the GUARDIAN ® product line by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available.
2 • Never start or stop the unit with electrical loads connected to receptacles AND with connected devices turned ON. Start the engine and let it stabilize before connecting electrical loads. Disconnect all electrical loads before shutting down the generator.
3 ELECTRICAL HAZARDS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages as does the generator when it is in operation.
1.1 UNPACKING • Set the palleted carton on a rigid flat surface. • Remove staples along bottom of carton that fasten carton to pallet. Open carton from top. • Remove all packaging material. • Remove separate accessory box. • Lift carton off the generator.
5 1.2.3 BATTERY CONNECTION • The battery shipped with the generator has been provided fully charged. Caution must be taken when connecting the battery. • Cut the tie wrap cable holding the RED and BLACK battery cables to the stator. • Connect the RED battery cable to the battery Positive terminal (+).
ITEM PART NO. QTY. DESCRIPTION 1 087968 1 SWITCH, ROCKER -/0 2 090418 1 OUTLET, 12VDC SNAP 3 0D6640 1 COVER, GOVERNOR CONTROL 4 090987 6 SCREW PPHM M3-0.5 X 12 5 0D2502 1 PANEL, SHEET METAL 6 068868 2 OUTLET 30A 120V RECEPT 7 022985 2 WASHER FLAT #6 8 043182 10 WASHER LOCK M3 9 051714 6 NUT HEX M3-0.
30 Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System Control Panel – Drawing No. 0E0227B 2.2 CORD SETS AND CONNECTION PLUGS 2.2.1 AC, 20 AMP, DUPLEX RECEPTACLE This is a 120 Volt outlet protected against overload by a 20 Amp push-to-reset circuit breaker.
Figure 9 - 120 VAC, 30 Amp Receptacle Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps. The outlet is protected by a 30 Amp push-to-reset circuit breaker. 2.2.4 120/240V AC, 30 AMP RECEPTACLE Use a NEMA L14-30 plug with this receptacle.
2.3 HOW TO USE THE GENERATOR If you have any problems operating your generator, please call the generator helpline at 1-800-333-1322. 2.3.1 GROUNDING THE GENERATOR The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground .
10 2.5 WATTAGE REFERENCE GUIDE Device . . . . . . . . . . . . . . . . . . . . . . .Running Watts *Air Conditioner (12,000 Btu) . . . . . . . . . . . . . . . . .1700 *Air Conditioner (24,000 Btu) . . . . . . . . . . . . . . . . .3800 *Air Conditioner (40,000 Btu) .
11 2.6.2 ADDING GASOLINE WARNING: Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. DO NOT light a cigarette or smoke when filling the fuel tank. Caution: Do not overfill the fuel tank. Always leave room for fuel expansion.
12 • Move engine CHOKE knob to “Full Choke” position. Figure 17 - Full Choke Position • To start engine, press and hold the Start/Run/Stop switch in the “Start” position. The engine will crank and attempt to start. When the engine starts, release the switch to the run position.
2.12 CHARGING A BATTERY DANGER! Storage batteries give off explosive hydrogen gas while recharging. An explosive mixture will remain around the battery for a long time after it has been charged. The slightest spark can ignite the hydrogen and cause an explosion.
3.2.1 GENERATOR SPECIFICATIONS MODEL GPS 12500 GPS 15000 Model # 004451-1 004582-1 Rated Max. Power 12.5 kW 15.0 kW Surge Power 18.75 kW 22.5 kW Rated AC Voltage 120/240 120/240 Rated Max AC Load Current @ 240V 52.0 Amps 62.5 Amps Current @ 120V 104.0 Amps 125.
15 3.3 GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.
16 3.3.6 REPLACING THE SPARK PLUG Use Champion RC14YC spark plug or equivalent. The correct air gap is 0.76 mm (0.030 in.). Replace the plug once each year . This will help your engine start easier and run better. 1. Stop the engine and pull the spark plug wire off of the spark plug.
Figure 21 - Spark Arrestor 3.6 ADJUSTING VALVE CLEARANCE After the first 50 hours of operation, you should adjust the valve clearance in the engine. Important: If you feel uncomfortable about doing th.
18 Section 3 — Maintenance Commercial-Industrial-Residential Portable Generator System 3.7 GENERAL The generator should be started at least once every seven days and be allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following information as a guide to prepare it for storage.
18 Section 3 — Maintenance Commercial-Industrial-Residential Portable Generator System 3.7 GENERAL The generator should be started at least once every seven days and be allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following information as a guide to prepare it for storage.
Figure 21 - Spark Arrestor 3.6 ADJUSTING VALVE CLEARANCE After the first 50 hours of operation, you should adjust the valve clearance in the engine. Important: If you feel uncomfortable about doing th.
16 3.3.6 REPLACING THE SPARK PLUG Use Champion RC14YC spark plug or equivalent. The correct air gap is 0.76 mm (0.030 in.). Replace the plug once each year . This will help your engine start easier and run better. 1. Stop the engine and pull the spark plug wire off of the spark plug.
15 3.3 GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.
3.2.1 GENERATOR SPECIFICATIONS MODEL GPS 12500 GPS 15000 Model # 004451-1 004582-1 Rated Max. Power 12.5 kW 15.0 kW Surge Power 18.75 kW 22.5 kW Rated AC Voltage 120/240 120/240 Rated Max AC Load Current @ 240V 52.0 Amps 62.5 Amps Current @ 120V 104.0 Amps 125.
2.12 CHARGING A BATTERY DANGER! Storage batteries give off explosive hydrogen gas while recharging. An explosive mixture will remain around the battery for a long time after it has been charged. The slightest spark can ignite the hydrogen and cause an explosion.
12 • Move engine CHOKE knob to “Full Choke” position. Figure 17 - Full Choke Position • To start engine, press and hold the Start/Run/Stop switch in the “Start” position. The engine will crank and attempt to start. When the engine starts, release the switch to the run position.
11 2.6.2 ADDING GASOLINE WARNING: Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. DO NOT light a cigarette or smoke when filling the fuel tank. Caution: Do not overfill the fuel tank. Always leave room for fuel expansion.
10 2.5 WATTAGE REFERENCE GUIDE Device . . . . . . . . . . . . . . . . . . . . . . .Running Watts *Air Conditioner (12,000 Btu) . . . . . . . . . . . . . . . . .1700 *Air Conditioner (24,000 Btu) . . . . . . . . . . . . . . . . .3800 *Air Conditioner (40,000 Btu) .
2.3 HOW TO USE THE GENERATOR If you have any problems operating your generator, please call the generator helpline at 1-800-333-1322. 2.3.1 GROUNDING THE GENERATOR The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground .
Figure 9 - 120 VAC, 30 Amp Receptacle Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps. The outlet is protected by a 30 Amp push-to-reset circuit breaker. 2.2.4 120/240V AC, 30 AMP RECEPTACLE Use a NEMA L14-30 plug with this receptacle.
30 Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System Control Panel – Drawing No. 0E0227B 2.2 CORD SETS AND CONNECTION PLUGS 2.2.1 AC, 20 AMP, DUPLEX RECEPTACLE This is a 120 Volt outlet protected against overload by a 20 Amp push-to-reset circuit breaker.
ITEM PART NO. QTY. DESCRIPTION 1 087968 1 SWITCH, ROCKER -/0 2 090418 1 OUTLET, 12VDC SNAP 3 0D6640 1 COVER, GOVERNOR CONTROL 4 090987 6 SCREW PPHM M3-0.5 X 12 5 0D2502 1 PANEL, SHEET METAL 6 068868 2 OUTLET 30A 120V RECEPT 7 022985 2 WASHER FLAT #6 8 043182 10 WASHER LOCK M3 9 051714 6 NUT HEX M3-0.
5 1.2.3 BATTERY CONNECTION • The battery shipped with the generator has been provided fully charged. Caution must be taken when connecting the battery. • Cut the tie wrap cable holding the RED and BLACK battery cables to the stator. • Connect the RED battery cable to the battery Positive terminal (+).
1.1 UNPACKING • Set the palleted carton on a rigid flat surface. • Remove staples along bottom of carton that fasten carton to pallet. Open carton from top. • Remove all packaging material. • Remove separate accessory box. • Lift carton off the generator.
3 ELECTRICAL HAZARDS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages as does the generator when it is in operation.
2 • Never start or stop the unit with electrical loads connected to receptacles AND with connected devices turned ON. Start the engine and let it stabilize before connecting electrical loads. Disconnect all electrical loads before shutting down the generator.
INTRODUCTION Thank you for purchasing this model of the GUARDIAN ® product line by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available.
Owner’ s Manual • SAFETY • ASSEMBLY • OPERATION • TROUBLESHOOTING • ELECTRICAL DATA • PARTS • WARRANTY 1-800-333-1322 UL TRA SOURCE Portable Generator COMMERCIAL • INDUSTRIAL • RESIDENTIAL MODELS: 004 4 51 (12,500 W A TT) 004582 (15,000 W A TT) AUTHORIZED DEALER SUPPORT: GENERAC POWER SYSTEMS, INC.
Owner’ s Manual • SAFETY • ASSEMBLY • OPERATION • TROUBLESHOOTING • ELECTRICAL DATA • PARTS • WARRANTY 1-800-333-1322 UL TRA SOURCE Portable Generator COMMERCIAL • INDUSTRIAL • RES.
An important point after buying a device Generac 4451 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Generac 4451 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Generac 4451 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Generac 4451 you will learn all the available features of the product, as well as information on its operation. The information that you get Generac 4451 will certainly help you make a decision on the purchase.
If you already are a holder of Generac 4451, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Generac 4451.
However, one of the most important roles played by the user manual is to help in solving problems with Generac 4451. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Generac 4451 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center