Operating
Manual


digital audio signal. A higher sampling rate allows higher frequencies to be recorded. Studio recording systems use sampling rates of 44 kHz and above.
The digital input accepts an S/P-DIF digital audio signal having a word length up to 24 bits and sampling rate up to 55 kHz.
Genelec 2029A Digital near field mon- itor has a digital audio interface allow- ing you to input the digital audio straight into the loudspeaker. This has several significant advantages.
The DA converter has an interpolator increasing the internal sampling rate to four times the original, before inter- polation to 128 times the original sam- pling frequency in a fourth order delta- sigma modulator, and digital-to-ana- log conversion in a switched capaci- tor integrator and an analog low-pass filter. This conversion process has high resilience to clock jitter and excellent linearity.
Turning the digital presentation to an analog signal using a DA converter involves significant sources of error. Your digital-to-analog converter may have inferior performance. It may be misaligned with your amplifiers. The interface between the converter and the amplifier may distort the signal or it may change the frequency balance. Your monitoring volume level may need to be adjusted in the digital do- main instead of analog.
When you are working with a digital audio workstation or you are process- ing audio in a modern studio, your sig- nal is digital. The 2029A Digital allows you to listen to what you have in your digital format.
The 2029A Digital supports all the same modes of operation as the ana- log 1029A. You can use it with a sub- woofer. You can use it in surround au- dio systems. You can even use the 2029A Digital as an analog speaker.
Drivers
Genelec 2029A Digital allows you to solve all of these problems. The align- ment of the whole system right from the digital input connector is carefully balanced, to make sure that you hear the whole digital truth, and nothing but the truth. All you have to do is to supply the digital signal, and adjust for the volume you desire.
The bass frequencies are reproduced by a 130 mm (5") bass driver mounted in a 4.5 litre vented cabinet. The -3 dB point lies at 68 Hz and the frequency response extends down to 65 Hz (-6 dB).
Due to its compact size, integrated construction, excellent dispersion and precise stereo imaging, this speaker system is ideal for near field monitor- ing, mobile vans, digital audio work- stations, broadcast and TV control rooms, surround sound systems, home studios, multimedia applications and also computer soundcards. As an ac- tive speaker this unit contains all you need- drivers, power amplifiers, active crossover filters and protection circuit- ry. The Directivity Control Waveguide (DCW™) technology provides excel- lent frequency balance even in diffi- cult acoustic environments.
The high frequency driver is a 19 mm (3/4") metal dome. Uniform dispersion is achieved with the revolutionary DCW™ Technology pioneered by Genelec.
The IEC958 or EIAJ CP-340 standards define one of the most popular digital audio interfaces in use today, often called S/P-DIF. It uses the same RCA connector and interface cables that most consumer audio equipment use today. The standard is versatile enough to be suitable for consumer use as well as studio audio signal pro- cessing. You typically find it on pro- fessional digital audio workstations and high quality sound cards.
Magnetic shielding is standard on Genelec 2029A Digital. Shielding is vital for applications such as video post production, where stray magnetic fields must be minimized.
Crossover
The active crossover network is acous- tically complementary and the slopes are 24 - 32 dB/octave. The crossover frequency is 3.3 kHz. The room re- sponse controls ('treble tilt', 'bass tilt' and 'bass roll-off') allow perfect repro- duction in any room installation.
The quality of a digital audio signal is defined by the two parameters: word length and sampling rate.
As the digital interface and amplifiers are built into the speaker enclosure, the only connections required are the mains supply and the digital input sig- nal, making the 2029A Digital very easy to set up and use.
Amplifiers
The word length defines how precise- ly the audio signal is represented. Longer word length leads to smaller noise and distortion level. The typical word length in CD records is 16 bits. Studio recording systems use word lengths of 20 bits and above.
The amplifier unit is built inside the speaker enclosure. The bass and tre- ble amplifiers both produce 40 W of output power. The fast, low distortion amplifiers are capable of driving a ster- eo pair to peak output sound pressure levels in excess of 110 dB at 1 m. The unit incorporates special circuitry for driver overload protection.
Digital interface Digital interface Digital interface Digital interface Digital interface
The digital audio interface comprises a digital audio receiver and a digital- to-analog converter (DA converter).
The sampling rate determines what fre- quencies can be represented in the

use one you should make absolutely sure that the connector is carrying the IEC958 formatted digital audio signal.
Contents of Genelec 2029A Contents of Genelec 2029A Contents of Genelec 2029A Contents of Genelec 2029A Contents of Genelec 2029A Digital delivery package Digital delivery package Digital delivery package Digital delivery package Digital delivery package
One of the 2029A Digital units (Right) has a matching RCA connector in the back of the unit. Locate the RCA con- nector (see figure 2) and notice the signal indicator LED in the front. Con- nect the RCA cable and switch on the power on both speakers. The LED should change colour from green to yellow.
Please make sure that you can identify these parts.
Turn the output level at the left speaker to maximum value. This calibrates the balance between the speakers. Adjust the desired output level at the right speaker (the one receiving the digital audio). Note that the output level ad- justment scales the maximum sound pressure level produced by the digital audio signal. Monitoring at very low output levels may not be accurate.
After unpacking, check that the mains voltage selector (see figure 2) is cor- rectly set and place the loudspeakers at their listening position, taking note of the listening axis (see figure 1). En- sure that the mains switches are off and the volume controls fully counter-clock- wise.
How to set up for analog signals How to set up for analog signals How to set up for analog signals How to set up for analog signals How to set up for analog signals
Remove the digital audio cable at the 2029A Digital. Observe that the LED should turn green.
Remove the interconnect cable be- tween the two Genelec 2029A Digital units.
To help you solve any problems, here are a few pointers.
How to set up for digital signals How to set up for digital signals How to set up for digital signals How to set up for digital signals How to set up for digital signals
Run normal XLR cables from your an- alog audio source to the XLR connec- tors on both 2029A Digital units.
Connect the special interconnect ca- ble between the XLR connectors of the two 2029A Digital monitors.
Adjust the output levels at the front of both 2029A Digital units independent- ly for left and right channels.
Connect an digital audio interface cable to your digital audio source. You can identify the right RCA connector on your audio source by looking for the words “Digital Output” or “S/P-DIF”. If you are sure your audio source has a digital audio output, but the cable does not fit the connector, you may have an equipment that is using a BNC con- nector instead of the standard RCA. You can find interface plugs that con- vert the BNC to an RCA. Before you


Figure 1: 2029A outer dimensions, with the reference axis between the bass and the treble drivers.


How to set up Genelec 1091A How to set up Genelec 1091A How to set up Genelec 1091A How to set up Genelec 1091A How to set up Genelec 1091A subwoofer
A standard Genelec 1091A subwoof- er package contains cables to connect to both 2029A Digital units. The cables have 1/4" (6mm) plugs that connect to the 2029A Digital units (see figure 5). On each 2029A Digital, flip the tone control switch number 2 to "ON" posi- tion. This is the right setting when the subwoofer 1091A is used.
Setting tone controls Setting tone controls Setting tone controls Setting tone controls Setting tone controls
The response of the system may have to be adjusted to match the acoustic environment. The adjustment is done by setting the tone control switches on the rear panel. The tone control has four switches and can adjust 'treble tilt', 'bass tilt' and 'bass roll-off.' The facto- ry settings for these are 'ALL OFF' to give a flat anechoic response. See Figure 6 for suggested tone control settings in differing acoustic environ- ments. Figure 8 shows the effect of the controls on the anechoic response. Always start adjustment by setting all switches to 'OFF' position. Then set a switch to 'ON' position to select the necessary response curve.
Console top mounting. Console top mounting. Console top mounting. Console top mounting. Console top mounting.
Avoid mounting Genelec 2029A Digit- al monitors directly on the console top. Instead, position the speakers slightly behind the console by using floor stands, wall mounts or microphone stands. This minimizes sound colour- ing reflections from the console sur- face.
Figure 4. Cabling scheme for analog setup

Room placement. Room placement. Room placement. Room placement. Room placement.
To produce a true and accurate stereo image the monitors must have exactly similar frequency responses. When placed in a room monitor responses change due to reflections of the sound waves from the room’s boundaries. It is necessary to place the monitors at the same height and also at the same distance from the front and side walls so that reflections, and therefore changes to the frequency response, are similar.
To avoid differences in frequency re- sponses due to reflections from the
Figure 5. Cabling and 2029A tone control settings when using subwoofer 1091A.


be used in conjunction with the wall hanging key holes. The 2029A Digital can be placed horizontally or vertical- ly. Enclosed is also a bag containing four large and four small friction pads. The larger pads are for the base of the 2029A Digital, and if placed horizon- tally, the smaller pads may be used on the side. There are recesses on the speaker cabinet where the pads fit.
There are no user serviceable parts are in the unit. Maintenance or repair of the 2029A Digital units should be done by qualified service personnel only.
Figure 6. Suggested tone control settings for various acoustic environments

The 2029A Digital has been designed in accordance with international safe- ty standards. To ensure safe operation and to maintain the instrument in safe operating condition, the following warnings and cautions must be ob- served:
Servicing and adjustment should only be performed by qualified service per- sonnel.
Figure 7. Tone control switches on the back panel of 2029A Left. Note that the digital audio receiving speaker (Right) has different labelling.
Do not use this product with an un- earthed mains cable as this may com- promise electrical safety.

front wall, the monitors should be placed either nearer than 1m or further than 3m from the front wall. Placement close to the front wall (
This equipment is capable of produc- ing sound pressure levels in excess of 85 dB, which may cause permanent hearing damage.
Free flow of air behind the loudspeak- er is necessary to maintain sufficient cooling. Do not obstruct airflow around the loudspeakers.
The monitors should be aimed toward the listening position. This maximizes the ratio of direct sound to reflected sound and the listener is able to hear more of the material and less of the room effects. Subjectively this is per- ceived as cleaner sound and superior stereo imaging.
Do not insert any objects through the bass reflex ports on the face of the unit, as this may damage the electronics in- side the loudspeaker.
Do not run an analog audio signal to the digital input RCA connector. Do- ing so may overload your audio equip- ment output and cause them perma- nent damage.
Mounting Options Mounting Options Mounting Options Mounting Options Mounting Options
Figure 8 shows the three possibilities for mounting the 2029A Digital. On the base of the monitor is a 3/8" UNC thread- ed hole which accommodates a stand- ard microphone stand. On the rear there are two methods to suspend the loudspeaker. An Omnimount® size 50 bracket can be used, two M6x10 mm screws are required. 4 mm diameter screws with suitable size heads can
This product is guaranteed for a peri- od of ONE year against faults in mate- rials or workmanship. Refer to supplier for full sales and guarantee terms.
Figure 8. Mounting options of the 2029A Digital


Figure 9: The effect of 'treble tilt', 'bass tilt' and 'bass roll-off' controls in free field. Figure 10: Horizontal directivity characteristics and power response of 2029A Digital in its vertical configuration measured at 1m in free field.
SYSTEM SPECIFICATIONS
CROSSOVER SECTION
DIGITAL SECTION
Inputs:
Input 1: XLR female, balanced 10 kOhm Input 2: 1/4 " Jack socket, balanced 10 kOhm
Free field frequency response of system:
Volume control:
70 Hz - 18 kHz (± 2.5 dB)
Variable from Mute to -6 dBu for 100 dB SPL output @ 1m
Maximum short term sine wave acoustic output on axis in half space, averaged from100 Hz to 3 kHz:
Subsonic filter below 68 Hz :
@ 1m > 100 dB SPL @ 0.5m > 106 dB SPL
1091A Subwoofer output (input 2) at 100db SPL: -23 dBu into 33kOhm load
Maximum long term RMS acousticoutput in same conditions with IECweighted noise (limited by driver unit protection circuit):
Ultrasonic filter above 25 kHz:
@ 1m > 98 dB SPL @ 0.5m > 104 dB SPL
Crossover frequency, Bass/Treble:
Maximum peak acoustic output per pair on top of console, @ 1 m from the engineer with music material:
3.3 kHz
Crossover acoustical slopes:
AMPLIFIER SECTION
Treble tilt control operating range:
Self generated noise level in free field @ 1m on axis:
0 to -2 dB @ 15 kHz
< 10 dB (A-weighted)
Bass roll-off control operating in a -6 dB step @ 85 Hz (to be used in conjunction with the 1091A subwoofer)
Bass amplifier output power with an 8 Ohm load:
Harmonic distortion at 85 dB SPL @ 1m on axis:
Bass tilt control operating range in -2 dB steps:
Treble amplifier output power with an 8 Ohm load:
0 to -6 dB @ 150 Hz
Drivers: Bass 130 mm (5") cone Treble 19 mm (3/4") metal dome Both drivers are magnetically shielded.
Long term output power is limited by driver unit protection circuitry.
The 'CAL' position is with all tone controls set to 'off' and the input sensitivity control to maximum (fully clockwise).
Amplifier system distortion at nominal output:
THD < 0.08% SMPTE-IM < 0.08% CCIF-IM < 0.08% DIM 100 < 0.08%
Dimensions:
Height 247 mm (9 3/4") Width 151 mm ( 515/16") Depth 191 mm (7 1/2")
Signal to Noise ratio, referred to full output:
Bass > 90 dB Treble > 90 dB
Power consumption:
Idle 9 VA Full output 90 VA
Genelec Oy, Olvitie 5 FIN - 74100 IISALMI, FINLAND Phone: +358 - 17 - 83881 Telefax: +358 - 17 - 812267 Web: http://www.genelec.com E-mail: genelec@genelec.com
Genelec document DR29101 COPYRIGHT GENELEC OY 1998 All data subject to change without prior notice
18 dB/octave · 12 dB/octave · > 110 dB