Genelec 1031A Monitoring System




EC Declaration of Conformity
This is to certify that the Genelec Monitoring System 1031A conforms to the following product specifications:
The product herewith complies with the require- ments of The Low Voltage Directive73/23/EEC and EMC Directive 89/336/EEC as amended by
Signed:
System
the filters are complementary and the slopes are 24 dB/octave. The crossover frequency is 2.2 kHz. The active crossover controls (‘treble tilt’, ‘bass tilt’ and ‘bass roll-off’) allow this speaker to be exactly matched to any room environment.
clearance for the amplifier is 10 centimeters (4") to any object. The space adjacent to the amplifier must either be ventilated or suf- ficiently large to dissipate heat so that the ambient temperature does not rise above 35 degrees Celsius (95°F).
The bi-amplified GENELEC 1031A is a two
way active monitoring speaker designed to
produce high SPL output, low coloration and
broad bandwidth in a small cabinet size. The
1031A is ideal for applications where space
Before connecting up, ensure that the mains switch is off (see figure 4). Check that the mains voltage selector is correctly set (Models sold in Europe have a fixed 230 V setting). Audio input is via a 10 kOhm bal- anced XLR connector, but unbalanced leads may be used as long as pin 3 is grounded to pin 1 of the XLR (see figure 3). Once the connection has been made, the speakers are ready to be switched on.
is at premium such as Near Field monitoring,
mobile vans, broadcast and TV control rooms,
The amplifier unit is mounted to the rear of the speaker enclosure on quick release vibration isolators, to ensure rattle free operation and long term reliability. The bass and treble amplifier produce respectively 120 Watts of short term power. The peak output sound pressure level of the 1031A exceeds 120 dB at 1 m. The unit incorporates special circuitry for driver overload and amplifier thermal overload protection. Variable input sensitivity allows for accurate level matching to console output section.
surround sound systems and budget and
home studios. Designed as an active speaker,
the 1031A contains drivers, power amplifiers,
active crossover filters and protection circuitry.
The Directivity Control Waveguide™ (DCW™)
technology used provides excellent frequency
balance even in difficult acoustic environments.
Setting the input sensitivity
The low frequencies are reproduced by a 210 mm (8”) bass driver loaded in a 15 liter vented cabinet. The -3 dB point lies at 47 Hz and the frequency response extends down to 43 Hz (- 6 dB). The high frequency driver is a 19 mm (3/4”) metal dome. Uniform dispersion con- trol is achieved with the innovative DCW Technology pioneered by Genelec, which also provides perfect phase and delay uni- formity at the crossover frequency.
The input sensitivity of the speakers can be matched to the output of the mixing console, or other source, by adjusting the input sensi- tivity control on the rear panel (see figure 4). A small screwdriver is needed for the adjust- ment. The manufacturer’s default setting for this control is -6 dBu (fully clockwise) which gives an SPL of 100 dB @1m with -6 dBu input level. Note that to get the full output level of 110 dB SPL, an input level of +4dBu is needed in this setting.
Each 1031A monitor is supplied with a mains cable and an operating manual. After unpacking, place the speaker so that its acoustical axis (see figure 2) is aimed towards the listening position. Do not place the speaker in a horizontal position as this may cause acoustical cancellation problems around the crossover frequency. Sufficient cooling for the amplifier must be ensured if the speaker is installed in a restricted space such as a cabinet or inte- grated into a wall structure. The minimum
Both drivers are magnetically shielded.
Crossover
The response of the system may also have to be adjusted to match the acoustic envi- ronment. The adjustment is done by setting
The active crossover network consists of two parallel bandpass filters. Acoustically,
Directive 93/68/EEC · Ilpo Martikainen · Ilpo Martikainen

TREBLE TILT
BASS TILT
USING THE TONE CONTROLS
BASS TILT CONTROL
OFF ON
ALL OFF
ALL OFF
REFER TO THE OPERATING MANUAL FOR SUGGESTED TONE CONTROL SETTINGS.
-2 dB -4 MUTE
FOR ACCURATE OPERATION ONLY ONE SWITCH IN EACH TONE CONTROL GROUP SHOULD BE ON AT A TIME.
OFF ON
-2 -4 dB -6 MUTE
BASS ROLL-OFF
FOR A FLAT FREE FIELD RESPONSE SET ALL TONE CONTROLS TO OFF.
-2 -4 dB -6 -8
INPUT SENSITIVITY REQUIRED FOR 100dB SPL@1m. REFER TO OPERATING MANUAL FOR MAXIMUM SPL.
INPUT CONNECTOR
Table 1. Suggested tone control settings in some typical situations
PIN 1 = GROUND PIN 2 = + INPUT PIN 3 = - INPUT
MAINS VOLTAGE SELECTOR (WHERE APPLICABLE)
MAINS VOLTAGE SELECTOR
MAINS INPUT 50 / 60 Hz 150 Watts 115 / 230 V
MAINS CONNECTOR
MAGNETICALLY SHIELDED
ON
MADE IN FINLAND
SERIAL NUMBER
MAINS SWITCH
WARNING
IT IS FORBIDDEN TO UNDO ANY SCREWS ON THIS EQUIPMENT. SERVICING AND ADJUSTMENT MUST ONLY BE CARRIED OUT BY QUALIFIED SERVICE PERSONNEL.
NEVER OPERATE THIS EQUIPMENT WITHOUT A PROPER EARTHED MAINS CONNECTION. DISCONNECT THE MAINS INPUT BEFORE REPLACING THE FUSE.
ENSURE THAT THE CORRECT VOLTAGE AND APPROPRIATE FUSE ARE SELECTED BEFORE CONNECTING TO THE MAINS SUPPLY.
THIS EQUIPMENT IS CAPABLE OF PRODUCING SOUND PRESSURE LEVELS IN EXCESS OF 85dB WHICH MAY CAUSE PERMANENT HEARING DAMAGE.
Figure 1. Amplifier panel layout of the 1031A Figure 2. Location of the acoustic axis
Figure 3. RCA to XLR cable
the three tone control switch groups ‘treble tilt’, ‘bass tilt’ and ‘bass roll-off’ on the rear panel of the amplifier. The factory settings for these controls are ‘All Off’ to give a flat anechoic response. See Table 1 for sug- gested tone control settings. Figure 5 shows the effect of the controls on the anechoic response. Always start adjustment by setting all switches to ‘OFF’ position. Then set only one switch to the ’ON’ position to select the response curve needed. If more than one switch is set to ‘ON’ (within one switch group) the attenuation value is not accurate.
The speaker is provided with two status
LED's marked 'OVL' and 'ON'. The green
ON-LED when lit indicates that the speaker
is ready for use. The red OVL-LED indicates
that the amplifier is overloaded or the driver
protection circuit is activated. In both cases
reduce the signal level so that the LED stops
blinking. If the OVL-LED stays on constantly it
indicates that the amplifier thermal protection
is activated. Let the amplifier cool down and
check that the ventilation at the rear side of
the speaker is not blocked. There should be
Vertical / horizontal mounting
a clearance of more than 4" (10cm) between
This equipment is capable of producing sound
The speakers are normally delivered set up for vertical mounting. Horizontal mount- ing should be avoided due to the increased likelihood of early reflections that degrade the the direct sound. If horizontal mounting is needed the DCW plate may be rotated so that the Genelec logo remains horizontal by removing the four corner screws of the DCW and carefully lifting and turning the DCW.
speaker rear and any solid surface.
pressure levels in excess of 85 dB, which
may cause permanent hearing damage.
Accessories
No user serviceable parts are to be found within the amplifier unit. Any maintenance or repair of the 1031A unit should only be undertaken by qualified service personnel.
Order code Protective grille 1031-409 Wall mount 1031-404-V/H* Floor stand 1031-405-V/H*
Although the 1031A has been designed in accordance with international safety standards, to ensure safe operation and to maintain the instrument under safe operating conditions, the following warnings and cau- tions must be observed:
*State the desired speaker orientation V=vertical or H=horizontal when ordering these accessories.
If the 1031A’s are used for near field monitor- ing, avoid mounting them on the meter bridge of the console. Instead position the speakers slightly behind the console by using floor stands or wall mounts. This prevents the first reflections from the console surface from coloring the sound.
This product is supplied with one year guar- antee against manufacturing faults or defects that might alter the performance of the 1031A unit. Refer to supplier for full sales and guar- antee terms.



AUDIO PRECISION 1031anec vs 07 SEP 93 10:04:11 LEVEL(dBr) FREQ(Hz)
Figure 4. The upper curve group shows the horizontal directivity characteristics of the 1031A in vertical configuration measured at 1 m. The lower curve is a 1/3 octave band power response, measured in an IEC approved reverberation chamber.
Figure 5. The curves show the effect of the bass tilt, treble tilt and bass roll-off controls on the free field response.
Bass amplifier short term output power with a 8 Ohm load: 120 W
Treble amplifier short term output power with an 8 Ohm load: 120 W
Free field frequency response of system:
48 Hz - 22 kHz (± 2 dB)
Maximum short term sine wave acoustic output on axis in half space, av er aged from 100 Hz to 3 kHz:
Input level for 100 dB SPL output @ 1m:
Long term output power is limited by driver unit protection circuitry.
variable from +6 to -6 dBu
@ 1m > 110 dB SPL @ 0.5m > 116 dB SPL
Input level for maximum short term sine wave output of 110 dB SPL @ 1m:
Amplifier system distortion at nominal out put:
THD < 0.05% SMPTE-IM < 0.05% CCIF-IM < 0.05% DIM 100 < 0.05%
Maximum long term RMS acoustic output in same conditions with IEC weighted noise (limited by driver unit pro tec tion cir cuit):
variable from +16 to +4 dBu
@ 1m > 101 dB SPL @ 0.5m > 107 dB SPL
Signal to Noise ratio, referred to full out put:
Bass > 100 dB Treble > 100 dB
Maximum peak acoustic output per pair above console top, @ 1 m from the engineer with music ma te ri al: > 120 dB
Treble tilt control operating range in 2 dB steps:
from +2 to -4 dB & MUTE
Self generated noise level in free field @ 1m on axis: < 10 dB (A-weighted)
Bass roll-off control operating range in 2 dB steps:
from 0 to -8 dB @ 40 Hz
Harmonic distortion at 90 dB SPL @ 1m on axis:
Bass tilt control operating range in 2 dB steps:
from 0 to -6 dB @ 80 Hz & MUTE
Drivers: Bass 210 mm (8") cone Treble 19 mm (3/4") metal dome Both drivers are magnetically shielded.
The 'CAL' position is with all tone con trols set to 'off' and the input sensitivity con trol to maximum (fully clockwise).
Height 393 mm (15 1/2") Width 250 mm ( 9 7/8") Depth 290 mm (11 7/16")
Genelec Document D1031AR001 Copyright Genelec Oy 6.2003. All data subject to change without prior notice www.genelec.com
International enquiries:
In the U.S. please contact:
In China please contact:

Genelec, Inc., 7 Tech Circle
Genelec China Representative Office
Natick, MA 01760, USA
Soho New Town, 88 Jianguo Road
Phone +358 17 83881
Phone +1 508 652 0900
Fax +358 17 812 267
Fax +1 508 652 0909
Email genelec@genelec.com
Email genelec.usa@genelec.com
Phone +86 10 8580 2180
Fax +86 10 8580 2181
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.