EN
Genelec logo
Official user manual

Genelec Active Studio Monitor (1031A)

4 pages·1.2 MB·Portable Speaker·PDF·ENDEFRITNLJA
Genelec Active Studio Monitor (1031A)
Table of Contents 43 sections Operating Manual 1031A · Genelec 1031A Monitoring System · System · Amplifiers · … ShowHide
Page 1 of the Genelec Active Studio Monitor (1031A) user manual — Operating Manual 1031A
Page 1 · click to enlarge
Page 1

Operating Manual 1031A

Genelec 1031A Monitoring System

Genelec Active Studio Monitor (1031A) — Operating Manual 1031A diagram (page 1)
Fig. 1 · Operating Manual 1031A
Genelec Active Studio Monitor (1031A) — Operating Manual 1031A diagram (page 1)
Fig. 2 · Operating Manual 1031A
Page 2 of the Genelec Active Studio Monitor (1031A) user manual — Setting tone controls
Page 2 · click to enlarge
Page 2
Genelec Active Studio Monitor (1031A) — System diagram (page 2)
Fig. 3 · System

EC Declaration of Conformity

This is to certify that the Genelec Monitoring System 1031A conforms to the following product specifications:

SafetyEN 60065 EMC: EN 55013, EN 55020, EN 61000-3-2 and EN 61000 3-3

The product herewith complies with the require- ments of The Low Voltage Directive73/23/EEC and EMC Directive 89/336/EEC as amended by

Signed:

PositionManaging Director Date: 20-Sep-2001

Genelec 1031A Monitoring System

System

the filters are complementary and the slopes are 24 dB/octave. The crossover frequency is 2.2 kHz. The active crossover controls (‘treble tilt’, ‘bass tilt’ and ‘bass roll-off’) allow this speaker to be exactly matched to any room environment.

clearance for the amplifier is 10 centimeters (4") to any object. The space adjacent to the amplifier must either be ventilated or suf- ficiently large to dissipate heat so that the ambient temperature does not rise above 35 degrees Celsius (95°F).

The bi-amplified GENELEC 1031A is a two

way active monitoring speaker designed to

produce high SPL output, low coloration and

broad bandwidth in a small cabinet size. The

1031A is ideal for applications where space

Before connecting up, ensure that the mains switch is off (see figure 4). Check that the mains voltage selector is correctly set (Models sold in Europe have a fixed 230 V setting). Audio input is via a 10 kOhm bal- anced XLR connector, but unbalanced leads may be used as long as pin 3 is grounded to pin 1 of the XLR (see figure 3). Once the connection has been made, the speakers are ready to be switched on.

Amplifiers

is at premium such as Near Field monitoring,

mobile vans, broadcast and TV control rooms,

The amplifier unit is mounted to the rear of the speaker enclosure on quick release vibration isolators, to ensure rattle free operation and long term reliability. The bass and treble amplifier produce respectively 120 Watts of short term power. The peak output sound pressure level of the 1031A exceeds 120 dB at 1 m. The unit incorporates special circuitry for driver overload and amplifier thermal overload protection. Variable input sensitivity allows for accurate level matching to console output section.

surround sound systems and budget and

home studios. Designed as an active speaker,

the 1031A contains drivers, power amplifiers,

active crossover filters and protection circuitry.

The Directivity Control Waveguide™ (DCW™)

technology used provides excellent frequency

balance even in difficult acoustic environments.

Drivers

Setting the input sensitivity

The low frequencies are reproduced by a 210 mm (8”) bass driver loaded in a 15 liter vented cabinet. The -3 dB point lies at 47 Hz and the frequency response extends down to 43 Hz (- 6 dB). The high frequency driver is a 19 mm (3/4”) metal dome. Uniform dispersion con- trol is achieved with the innovative DCW Technology pioneered by Genelec, which also provides perfect phase and delay uni- formity at the crossover frequency.

The input sensitivity of the speakers can be matched to the output of the mixing console, or other source, by adjusting the input sensi- tivity control on the rear panel (see figure 4). A small screwdriver is needed for the adjust- ment. The manufacturer’s default setting for this control is -6 dBu (fully clockwise) which gives an SPL of 100 dB @1m with -6 dBu input level. Note that to get the full output level of 110 dB SPL, an input level of +4dBu is needed in this setting.

Installation

Each 1031A monitor is supplied with a mains cable and an operating manual. After unpacking, place the speaker so that its acoustical axis (see figure 2) is aimed towards the listening position. Do not place the speaker in a horizontal position as this may cause acoustical cancellation problems around the crossover frequency. Sufficient cooling for the amplifier must be ensured if the speaker is installed in a restricted space such as a cabinet or inte- grated into a wall structure. The minimum

Both drivers are magnetically shielded.

Setting tone controls

Crossover

The response of the system may also have to be adjusted to match the acoustic envi- ronment. The adjustment is done by setting

The active crossover network consists of two parallel bandpass filters. Acoustically,

Directive 93/68/EEC · Ilpo Martikainen · Ilpo Martikainen

Page 3 of the Genelec Active Studio Monitor (1031A) user manual — Guarantee
Page 3 · click to enlarge
Page 3
Speaker Mounting PositionTreble tiltBass tiltBass roll-off Flat anechoic responseNoneNoneNone Free standing in a damped roomNone-2 dBNone Free standing in a reverberant roomNone-4 dB-2 dB Near field or console bridgeNone-4 dB-4 dB In a cornerNone-4 dB-4 dB

TREBLE TILT CONTROL

TREBLE TILT

BASS TILT

USING THE TONE CONTROLS

BASS TILT CONTROL

OFF ON

ALL OFF

ALL OFF

REFER TO THE OPERATING MANUAL FOR SUGGESTED TONE CONTROL SETTINGS.

-2 dB -4 MUTE

FOR ACCURATE OPERATION ONLY ONE SWITCH IN EACH TONE CONTROL GROUP SHOULD BE ON AT A TIME.

BASS ROLL-OFF CONTROL

OFF ON

-2 -4 dB -6 MUTE

OFF ON

BASS ROLL-OFF

FOR A FLAT FREE FIELD RESPONSE SET ALL TONE CONTROLS TO OFF.

-2 -4 dB -6 -8

INPUT SENSITIVITY CONTROL

INPUT SENSITIVITY REQUIRED FOR 100dB SPL@1m. REFER TO OPERATING MANUAL FOR MAXIMUM SPL.

ALL OFF

CAL POSITION ALL CONTROLSOFF INPUT SENSITIVITY : -6dBu

INPUT SENSITIVITY

INPUT CONNECTOR

Table 1. Suggested tone control settings in some typical situations

PIN 1 = GROUND PIN 2 = + INPUT PIN 3 = - INPUT

1 SIGNAL INPUT

MAINS VOLTAGE SELECTOR (WHERE APPLICABLE)

MAINS VOLTAGE SELECTOR

MAINS INPUT 50 / 60 Hz 150 Watts 115 / 230 V

1031A BI-AMPLIFIED MONITORING SYSTEM GENELECR

MAINS CONNECTOR

MAGNETICALLY SHIELDED

ON

MADE IN FINLAND

SERIAL NUMBER

MAINS SWITCH

WARNING

IT IS FORBIDDEN TO UNDO ANY SCREWS ON THIS EQUIPMENT. SERVICING AND ADJUSTMENT MUST ONLY BE CARRIED OUT BY QUALIFIED SERVICE PERSONNEL.

ELECTRIC SHOCK HAZARD!

NEVER OPERATE THIS EQUIPMENT WITHOUT A PROPER EARTHED MAINS CONNECTION. DISCONNECT THE MAINS INPUT BEFORE REPLACING THE FUSE.

ENSURE THAT THE CORRECT VOLTAGE AND APPROPRIATE FUSE ARE SELECTED BEFORE CONNECTING TO THE MAINS SUPPLY.

THIS EQUIPMENT IS CAPABLE OF PRODUCING SOUND PRESSURE LEVELS IN EXCESS OF 85dB WHICH MAY CAUSE PERMANENT HEARING DAMAGE.

Figure 1. Amplifier panel layout of the 1031A Figure 2. Location of the acoustic axis

Figure 3. RCA to XLR cable

the three tone control switch groups ‘treble tilt’, ‘bass tilt’ and ‘bass roll-off’ on the rear panel of the amplifier. The factory settings for these controls are ‘All Off’ to give a flat anechoic response. See Table 1 for sug- gested tone control settings. Figure 5 shows the effect of the controls on the anechoic response. Always start adjustment by setting all switches to ‘OFF’ position. Then set only one switch to the ’ON’ position to select the response curve needed. If more than one switch is set to ‘ON’ (within one switch group) the attenuation value is not accurate.

Overload indicators

2. Do not use this product with an unearthed mains cable as this may lead to personal injury. 3. To prevent fire or electric shock, do not expose the unit to water or moisture. Do not place any objects filled with liquid, such as vases on the speaker or near it. 4. Note that the amplifier is not completely disconnected from the AC mains service unless the mains power cord is removed from the amplifier or the mains outlet.

The speaker is provided with two status

LED's marked 'OVL' and 'ON'. The green

ON-LED when lit indicates that the speaker

is ready for use. The red OVL-LED indicates

that the amplifier is overloaded or the driver

protection circuit is activated. In both cases

reduce the signal level so that the LED stops

blinking. If the OVL-LED stays on constantly it

indicates that the amplifier thermal protection

is activated. Let the amplifier cool down and

check that the ventilation at the rear side of

the speaker is not blocked. There should be

WARNING!

Vertical / horizontal mounting

a clearance of more than 4" (10cm) between

This equipment is capable of producing sound

The speakers are normally delivered set up for vertical mounting. Horizontal mount- ing should be avoided due to the increased likelihood of early reflections that degrade the the direct sound. If horizontal mounting is needed the DCW plate may be rotated so that the Genelec logo remains horizontal by removing the four corner screws of the DCW and carefully lifting and turning the DCW.

speaker rear and any solid surface.

pressure levels in excess of 85 dB, which

may cause permanent hearing damage.

Maintenance

Accessories

No user serviceable parts are to be found within the amplifier unit. Any maintenance or repair of the 1031A unit should only be undertaken by qualified service personnel.

Order code Protective grille 1031-409 Wall mount 1031-404-V/H* Floor stand 1031-405-V/H*

Safety considerations

Although the 1031A has been designed in accordance with international safety standards, to ensure safe operation and to maintain the instrument under safe operating conditions, the following warnings and cau- tions must be observed:

*State the desired speaker orientation V=vertical or H=horizontal when ordering these accessories.

Console top mounting

If the 1031A’s are used for near field monitor- ing, avoid mounting them on the meter bridge of the console. Instead position the speakers slightly behind the console by using floor stands or wall mounts. This prevents the first reflections from the console surface from coloring the sound.

Guarantee

This product is supplied with one year guar- antee against manufacturing faults or defects that might alter the performance of the 1031A unit. Refer to supplier for full sales and guar- antee terms.

1. Servicing and adjustment must only be performed by qualified service personnel. The amplifier’s rear panel must not be opened.
Show 21 more labels / short text on this page
dB · dB · +2 · +2 · 4kHz 20kHz · 20Hz 600Hz · dB · +6 · +4 · +2 · dBu · 20Hz 100Hz · ˜ · f · 495 mm · Cable · Screen RCA (Source) · XLR (Speaker) · 290 mm · 290 mm · 320 mm
Page 4 of the Genelec Active Studio Monitor (1031A) user manual — AMPLIFIER SECTION CROSSOVER SECTION SYSTEM SPECIFICATIONS
Page 4 · click to enlarge
Page 4

1031A Operating Manual

Genelec Active Studio Monitor (1031A) — 1031A Operating Manual diagram (page 4)
Fig. 4 · 1031A Operating Manual
Genelec Active Studio Monitor (1031A) — 1031A Operating Manual diagram (page 4)
Fig. 5 · 1031A Operating Manual

AUDIO PRECISION 1031anec vs 07 SEP 93 10:04:11 LEVEL(dBr) FREQ(Hz)

Figure 4. The upper curve group shows the horizontal directivity characteristics of the 1031A in vertical configuration measured at 1 m. The lower curve is a 1/3 octave band power response, measured in an IEC approved reverberation chamber.

Figure 5. The curves show the effect of the bass tilt, treble tilt and bass roll-off controls on the free field response.

AMPLIFIER SECTION CROSSOVER SECTION SYSTEM SPECIFICATIONS

Lower cut-off frequency, -3 dB< 47 Hz Upper cut-off frequency, -3 dB: > 22 kHz
Input connector XLR femalepin 1 gnd pin 2 + pin 3 -

Bass amplifier short term output power with a 8 Ohm load: 120 W

Treble amplifier short term output power with an 8 Ohm load: 120 W

Free field frequency response of system:

48 Hz - 22 kHz (± 2 dB)

Input impedance10 kOhm bal anced

Maximum short term sine wave acoustic output on axis in half space, av er aged from 100 Hz to 3 kHz:

Input level for 100 dB SPL output @ 1m:

Long term output power is limited by driver unit protection circuitry.

variable from +6 to -6 dBu

@ 1m > 110 dB SPL @ 0.5m > 116 dB SPL

Input level for maximum short term sine wave output of 110 dB SPL @ 1m:

Amplifier system distortion at nominal out put:

THD < 0.05% SMPTE-IM < 0.05% CCIF-IM < 0.05% DIM 100 < 0.05%

Maximum long term RMS acoustic output in same conditions with IEC weighted noise (limited by driver unit pro tec tion cir cuit):

variable from +16 to +4 dBu

Subsonic filter below 45 Hz18 dB/octave Ultrasonic filter above 25 kHz: 12 dB/octave

@ 1m > 101 dB SPL @ 0.5m > 107 dB SPL

Signal to Noise ratio, referred to full out put:

Crossover frequency, Bass/Treble2.2 kHz Crossover acoustical slopes: 24 dB/octave

Bass > 100 dB Treble > 100 dB

Maximum peak acoustic output per pair above console top, @ 1 m from the engineer with music ma te ri al: > 120 dB

Treble tilt control operating range in 2 dB steps:

Mains voltage230, 100/200 or 115/230V according to region

from +2 to -4 dB & MUTE

Self generated noise level in free field @ 1m on axis: < 10 dB (A-weighted)

Bass roll-off control operating range in 2 dB steps:

Voltage operating range±10%

from 0 to -8 dB @ 40 Hz

Power consumptionIdle 30 VA Full output 160 VA

Harmonic distortion at 90 dB SPL @ 1m on axis:

Bass tilt control operating range in 2 dB steps:

Freq50...100 Hz < 3% > 100 Hz < 0.5%

from 0 to -6 dB @ 80 Hz & MUTE

Drivers: Bass 210 mm (8") cone Treble 19 mm (3/4") metal dome Both drivers are magnetically shielded.

The 'CAL' position is with all tone con trols set to 'off' and the input sensitivity con trol to maximum (fully clockwise).

Weight12,7 kg (28 lb) Dimensions:

Height 393 mm (15 1/2") Width 250 mm ( 9 7/8") Depth 290 mm (11 7/16")

Genelec Document D1031AR001 Copyright Genelec Oy 6.2003. All data subject to change without prior notice www.genelec.com

International enquiries:

In the U.S. please contact:

In China please contact:

Genelec Active Studio Monitor (1031A) — AMPLIFIER SECTION CROSSOVER SECTION SYSTEM SPECIFICATIONS diagram (page 4)
Fig. 6

Genelec, Inc., 7 Tech Circle

Genelec China Representative Office

Natick, MA 01760, USA

Soho New Town, 88 Jianguo Road

Phone +358 17 83881

Phone +1 508 652 0900

Fax +358 17 812 267

Fax +1 508 652 0909

Email genelec@genelec.com

Email genelec.usa@genelec.com

Phone +86 10 8580 2180

Fax +86 10 8580 2181

Show 4 more labels / short text on this page
Genelec, Olvitie 5 · FIN-74100, Iisalmi, Finland · D-1504, Chaoyang District · Beijing 100022, China
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Genelec Active Studio Monitor (1031A)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Genelec Active Studio Monitor (1031A)

Be the first to ask — other owners or our team will answer.

Original document

Genelec Active Studio Monitor (1031A) manual PDF

4 pages·1.2 MB·Portable Speaker·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…