PTDN600GM GE Profile™ 7.0 cu. ft. stainless steel capacity gas dryer with Steam and Sensor Dry™
*24-1/2" from the edge of the side panel to the front. 25-1/2" from front to edge of endcaps.

Dimensions and Installation Information (in inches)
Exhaust Option: When viewed from the front of the unit, exhaust 3-way via rear, left and bottom. Dryer is shipped exhausted to the rear. Alternate exhausting knockouts are supplied.
Gas: An individual, properly-grounded branch circuit, with a three-prong grounding- type receptacle, protected by a 15 or 20 amp circuit breaker or a time-delay fuse is required.
Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply requires a conversion kit. Check installation instructions for correct kit and have a qualified gas technician install a conversion kit. See dryer ducting information for proper installation.
Installation Information: For complete information, see installation instructions packed with your dryer.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

PTDN600GM GE Profile™ 7.0 cu. ft. stainless steel capacity gas dryer with Steam and Sensor Dry™
For complete information, see installation instructions packed with your dryer.
Ducting Materials: For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi- rigid) ducting can be used (Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4" diameter can be maintained throughout the entire length of the transition duct. Please see installation instructions packed with your dryer for complete instructions when using flexible metal (foil type) ducting.
Exhaust Length Calculation: 1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.
Minimum Clearances other than Alcove or Closet Installation: • Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryers must be exhausted to the outside.
Dryer Exhausting Information: Use metal duct only, vertical and horizontal ducting.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
Special Installation Requirements · Specification Created 7/10

PTDN600GM GE Profile™ 7.0 cu. ft. stainless steel capacity gas dryer with Steam and Sensor Dry™

Specification Created 7/10