Before you begin — Read these instructions completely and carefully. IMPORTANT - Save these instructions for local inspector’s use. IMPORTANT - OBSERVE ALL GOVERNING CODES AND ORDINANCES. Note to Installer - Be sure to leave these instructions with the Consumer. Note to Consumer - Keep these instructions with your Owner’s Manual for future reference.
This appliance must be properly grounded. See “Electrical Supply”, page 4.
If you received a damaged warming drawer, you should immediately contact your dealer or builder.
Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the GE Appliance Warranty. See the Use & Care Guide for warranty information.
Check with local utilities for electrical codes that apply in your area. Local codes vary. Installation electrical connections and grounding must comply with applicable codes. In the absence of local codes, the drawer should be installed in accordance with National Electrical Code ANSI/NFPA 70-1990 or latest edition.
For Monogram local service in your area, 1-800-444-1845. For Monogram service in Canada, call 1-888-880-3030. For Monogram Parts and Accessories, call 1-800-626-2002.
Contents Design Information Models Available 3 Product Dimensions 3 Accessories 3 Tools and Materials Required 3
Installation Preparation Advance Planning 4 Grounding the Appliance 4 Remove the Packaging and Parts 5 Installation Below a Countertop 5 Installation Below Wall Ovens 6
Installation Step 1: Provide Cabinet Support and Anti-Tip Bracket 7 Step 2: Install Warming Drawer 7

Models Available
ZTD910 30” Wide model ZKD910 27” Wide model
The warming drawers may be installed directly into a wall or wall oven cabinetry, or below a countertop.
Dimension A ZTD910 30” ZKD910 26-3/4”
Accessories ZXD27B, ZXD30B – This kit provides for the installation of a custom front panel on 27” and 30" black and white wide models.
JXPN1 – Warming drawer pan kit. This kit includes supports and a set of 5 pans which fit into 27" and 30" models.
JXPN2 – Warming drawer pan kit. This kit includes supports and a set of 3 pans which fit into 27" and 30" models.
Runners must be level, rigidly mounted and capable of supporting 150 pounds.

Advance Planning
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordi- nances.
Recessed Receptacle 7" Max. From Rear on Right Side.
Drill 1-1/2" Hole For Power Cord For Left or Right Side Outlet Location
This warming drawer must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.
IMPORTANT: (Please read carefully). The power cord of this appliance is equipped with a three-prong (grounding) plug that mates with a standard three-prong grounding wall receptacle to minimize the possibility of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the recep- tacle is properly grounded and has the correct polarity. •Where a standard two-prong wall receptacle is encountered, it is the personal responsibil- ity and obligation of the customer to have it replaced with a properly grounded three- prong wall receptacle. Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. DO NOT USE AN EXTENSION CORD.
the right side of the cutout, 7” from the back of the cabinet. In this location, the excess power cord should be coiled and secured to the warming drawer side with the power cord clip. •When two warming drawers are installed side to side, they can operate from the same receptacle.

Remove Packaging and Parts
Install 2x4 or 2x2 Anti-Tip Block Against Rear Cabinet Wall 9" From Floor to Bottom of Block 7"
Electrical Outlet 42" Max.
From Right Side.
Electrical Outlet Flush With Side of Cabinet 7" Max.
25" 1-1/2" Cabinet Top
Electrical Outlet 16" Max. From Left Side.
Install a Solid Barrier
1" Min.*
Dim. A
23-1/2" Min.
*Note: When installing the warming drawer below a cooktop, a solid barrier must be installed at least 1" from the lowest point of the bottom of cooktop burner box to the top of cutout. Use any solid material such as 1/4" thick plywood. Allow at least 1/4" air gap between the barrier and the top of the warming drawer. See label on top of the warming drawer for approved cooktop models.
Install a Solid Barrier
and a 1/4" Air Gap Above Warming Drawer
Installation below a cabinet drawer: The warming drawer may be installed beneath a cabinet drawer. In this installation, a solid barrier should be installed above the warming drawer to block access. Use any solid material such as 1/4" thick plywood. Allow at least 1/4" air gap between the barrier and the top of the warming drawer. Observe the 5" min. above the floor or 1" above the toekick minimum installation height. Note: If you are installing in frameless cabinets, it may be necessary to install 1/2” wide cleats to accept drawer mounting screws. See drawer to find exact locations of mounting screws. Side to Side Installation: Install two warming drawers in separate cutouts. Allow 2" min. between cutouts.
– Depth - 23-1/2” min. from inside back to
front of cabinet frame. – Width - 25-1/2” for 27” wide models,
28-1/2” for 30” wide models. – Height - 9-1/4”. •5” min. above floor or 1” above toekick. 23-1/4” from floor to bottom of cutout is recommended for under countertop installation. Installation below a cooktop: Warming drawers are approved for installa- tion below only certain specified cooktop models. See the label attached to the top of the warming drawer for approved models. A solid barrier and air gap between cooktop and warming drawer is required. See Note above.
2" Min.
Side to Side Installation

Installation Below Wall Ovens
23-1/2" Min. Inside
BELOW A SINGLE OVEN
2x2 or 2x4 Anti-Tip Block Against Rear Wall, 9" From Floor to Bottom of Block
2" Min.
Allow 5/8" Overlap on All Sides
1" Min. Above Toekick or Adjust to Oven Installation Height
23-1/2" Min. Inside
Dim. A Dim. B
INSTALLATION
ZKD27 25-1/2” 26-3/4”
BELOW A DOUBLE OVEN
Allow 5/8" Overlap on All Sides
2x2 or 2x4 Anti-Tip Block Against Rear Wall, 9" From Floor to Bottom of Block
2" Min.
1" Min. Above Toekick
The rough opening for the drawer must be:
– Depth – 23-1/2” min. from inside back to
front of cabinet frame. – Width – 25-1/2” for 27” wide models,
28-1/2” for 30” wide models. – Height - 9-1/4”. – Allow 2” min. between oven and drawer
cutouts for clearance of overlaps. Note: If you are installing in frameless cabinets, it may be necessary to install 1/2” wide cleats to accept drawer mounting screws. See drawer for mounting screw locations.

2"x 4" or Equivalent Runners
2"x 4" or Equivalent Runners
has been installed. Be sure supports are level. •The entire weight of the drawer is supported by the runners or solid floor and must be capable of supporting 150 lbs.
Install 2x4 or 2x2 Anti-Tip Block Against Rear Cabinet Wall 9" From Floor to Bottom of Block
2x4 or 2x2 Runners or Solid

® local service in your area, call 1-800-444-1845.
Monogram. We bring good things to life.
General Electric Company Louisville, KY 40225
Pub. No. 49-8937-1 Dwg. No. 164D3333P167
(N.D. 584) 9/02 977-0160-001-Rev. 1
®
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.